® A-25
P L U R A L C O M P O N E N T P R O P O R T I O N E R
Air operated, electrically heated, plural component proportioner
For spraying or dispensing 1:1 ratio polyurethane foam formulations and other 1:1 fast setting materials.
Not for use in explosive atmospheres or hazardous locations.
This model is field-configurable to the following supply voltages: 230 V, 1 Phase 230 V, 3 Phase 380 V, 3 Phase
2000 psi (14 MPa, 138 bar) Maximum Fluid Working Pressure 80 psi (550 kPa, 5.5 bar) Maximum Air Working Pressure
See page 3 for model information, including maximum working pressure and approvals.


All proportioners can be configured to operate on 380V (4 wire), 230V (3 wire), or 230V 1Ø.
Only available in Asia.
All systems include a proportioner, spray gun, and 60 ft (18.3 m) of heated hose.
Manuals are available at www.graco.com
Component manuals in English:
Proportioner Models

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
ELECTRIC SHOCK HAZARD This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.
TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.
PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. This equipment includes but is not limited to:
BURN HAZARD Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns:

FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury.
PRESSURIZED ALUMINUM PARTS HAZARD Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage.
THERMAL EXPANSION HAZARD Fluids subjected to heat in confined spaces, including hoses, can create a rapid rise in pressure due to the thermal expansion. Over-pressurization can result in equipment rupture and serious injury.
MOVING PARTS HAZARD Moving parts can pinch, cut or amputate fingers and other body parts.

Isocyanate Conditions
Moisture Sensitivity of Isocyanates
Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity. If used, this partially cured ISO will reduce performance and the life of all wetted parts.
Spraying or dispensing materials containing isocyanates creates potentially harmful mists, vapors, and atomized particulates.
Read material manufacturer’s warnings and material MSDS to know specific hazards and precautions related to isocyanates.
Prevent inhalation of isocyanate mists, vapors, and atomized particulates by providing sufficient ventilation in the work area. If sufficient ventilation is not available, a supplied-air respirator is required for everyone in the work area.
To prevent exposing ISO to moisture:
To prevent contact with isocyanates, appropriate personal protective equipment, including chemically impermeable gloves, boots, aprons, and goggles, is also required for everyone in the work area.
Some materials may become self-igniting if applied too thickly. Read material manufacturer’s warnings and material MSDS.
Foam Resins with 245 fa Blowing Agents
Some foam blowing agents will froth at temperatures above 90°F (33°C) when not under pressure, especially if agitated. To reduce frothing, minimize preheating in a circulation system.
Cross-contamination can result in cured material in fluid lines which could cause serious injury or damage equipment. To prevent cross-contamination of the equipment’s wetted parts, never interchange component A (isocyanate) and component B (resin) parts.

Changing the material types used in your equipment requires special attention to avoid equipment damage and downtime.

DataTrak can diagnose several problems with the pump. When the monitor detects a problem, the LED will flash and a diagnostic code will appear on the display.
To acknowledge the diagnosis and return to the normal
operating screen, press once to wake up the display, and once more to clear the diagnostic code screen.
Temperature control diagnostic codes appear on tem- perature display.
These alarms turn off heat. E99 clears automatically when communication is regained. Codes E03 through
E06 can be cleared by pressing . For other codes,
turn main power OFF then ON to clear.

between temperature control module and thermo- couples A and B (361) or FTS (21) [depending on which zone is displaying E01]. See Table 2, page 26. Ensure that all wires are securely connected to connector B.
Troubleshooting this equipment requires access to parts that may cause electric shock or other serious injury if work is not performed properly. Have a qualified electrician perform all electrical troubleshooting. Be sure to shut off all power to the equipment before repairing.
a. Set temperature setpoints far below displayed temperature.
Check which zone is displaying the E01 error.
b. Turn zone on. If temperature rises steadily, power module is failing.
c. Verify by swapping with another power module. See Replacing Temperature Control Assem- bly Modules, page 27.

d. If the swapped module does not fix the problem, the power module is not the cause.
b. Perform Transformer Primary Check and Transformer Secondary Check, starting on page 33.
E04: Fluid Temperature Sensor (FTS) or thermocouple disconnected

For hose zone: If error still occurs, perform Transformer Primary Check and Transformer Secondary Check, starting on page 33.
a. Hose zone: test hose continuity, page 31.

Communication Diagnostic Codes
Communications between the display and the motor control board or the temperature control module have been momentarily lost. Normally, when communication is lost, the corresponding display will show E99. The corresponding control board will register E30 (The red LED will flash 30 times). If communications are recon- nected, the display can show the E30 for a small time (no more than about two seconds). It should not be pos- sible for E30 to be shown continuously, unless there is a loose connection causing the display and the board to continuously loose and regain communication.
Check all wiring between the display and the control board.
Communications between the display and the tempera- ture control module has been lost. When communication is lost, the display will show E99.
Step 2 measures line voltage and should be done by a qualified electrician. If work is not performed properly it may cause electric shock or other serious injury.


Repairing this equipment requires access to parts that may cause electric shock or other serious injury if work is not performed properly. Electrical troubleshooting must be done by a qualified electrician. Be sure to shut off all power to equipment and lock out power at the source before repairing.
Before Beginning Repair

Flushing
Park the pumps at the end of the day to cycle compo- nent A pump to home position, submerging displace- ment rod.
Flush equipment only in a well-ventilated area. Do not spray flammable fluids. Do not turn on heaters while flushing with flammable solvents.

N

Only use flush solvents that are compatible with Fluoroelastomer seals. Non-compatible solvents will damage seals and cause hazardous conditions, such as high pressure leaks and pressure switch failure.
Park · Close Open

Problems
Try the recommended solutions in the order given for each problem, to avoid unnecessary repairs. Also, determine that all circuit breakers, switches, and con- trols are properly set and wiring is correct before assum- ing there is a problem.
Before performing any troubleshooting procedures:
Heat zones do not operate No power Connect power cord
Turn Main Disconnect Switch ON
Power cord not connected properly Check connections
No power when disconnect switch is turned on; using 230V, 1 phase or 230V, 3 phase power
Power terminal jumper still at 380V, 3 phase position, as shipped from fac- tory
Place jumpers in correct position; see Operation manual and label inside front lower cabinet.
External main supply power circuit breaker trips and Reactor disconnect switch fails when switch is turned on.
Power terminal jumper was left in 230V, 1 phase position. When using 230V, 3 phase or 380V, 3 phase power
Place jumpers in correct position; see Operation manual. Replace main power disconnect switch; see page 40.
No temperature display lights at startup
No power Connect power cord
Turn Main Disconnect Switch ON
Control power fuses blown Check and replace fuses on long ter- minal strip
Pump does not run up and down Motor control valve closed Open air motor shutoff valve
No air supply Air supply line not connected
Open inlet air ball valve
Air pressure regulators set at 0 psi Turn up air pressure regulators
Air motor shuttle valve is centered. Push button on top of air motor shut- tle valve.
Pump runs but no fluid pressure Fluid inlet ball valves closed Open fluid inlet ball valves
Troubleshooting

Fluid pressure low or dropping Air supply pressure low when spray- ing
Increase inlet air pressure
Increase air compressor size to meet flow requirements
Remove airline quick disconnects
Use 3/8 in. (0.95 cm) ID or larger air supply hose. Use 1/2 in. (12.7 mm) if longer than 25 ft (7.6 m).
Icing in air motor exhausts or mufflers Check inlet filter water separator; see
page 25. Stop spraying while ice melts.
Pump output low, but pressure is nor- mal
Obstructed gun impingement ports or filters
Flush and clean gun; see gun manual
One pressure gauge drops when pumps are stalled on both the upstroke and the downstroke
Leaking pump throat Repair pump; see 309577
Leak between pump and gun Check fluid tubes, heater, and hoses
Pressure Relief/Spray valve leaking back to supply
Spray gun is leaking on one side or plugged on the other side
Clean and repair spray gun
One pressure gauge drops when pumps are stalled on the downstroke, but not the upstroke
Inlet ball check not sealing Clean or replace; see 309577
Inlet check seat o-ring not sealing Repair pump; see 309577
One pressure gauge drops when pumps are stalled on the upstroke, but not the downstroke
Piston check ball not sealing Repair pump; see 309577
Piston packing not sealing Repair pump; see 309577
Loose piston stud in pump Repair pump; see 309577
Bad inside sleeve seal Repair o-ring; see 309577
A side rich; lack of B side A side gauge is low B side restriction downstream of gauge. Check gun check valve screen, mix module, or mix manifold restrictor.
A side impingement port is worn.
B side gauge is low B side material supply problem. Check B side inlet strainer and pump intake valve.
B side rich; lack of A side A side gauge is low A side material supply problem. Check A side inlet strainer and pump intake valve.
B side gauge is low A side restriction downstream of gauge. Check gun check valve screen, mix module, or mix manifold restrictor.
B side impingement port is worn.
Troubleshooting

Fluid pressures not balanced between A and B side
Fluid viscosities not equal Adjust A and B temperature settings to balance viscosity. Sometimes nor- mal if pressure offset is below 200 psi (14 bar)
Preheat material in drums by recircu- lating; see Operation manual
Inlet Y-strainer screen plugged on low pressure side
Clean inlet filter screen
Gun port or filter plugged on high pressure side
Clean or replace; see gun manual
Pump inlet ball not seating or sticking Clean seating; see pump manual
Drum fluid outlet supply hose too small
Use 3/4 in. (1.9 cm) ID hose with short length
Low side feed pump not working Turn on or repair feed pump
Pressure Relief/Spray valve leaking back to supply
Pump does not reverse direction Obstruction of air motor or pumps Check and clear obstruction
Unequal fluid pressure between UP/DOWN stroke
Feed pumps boost pressure on up stroke.
Reduce feed pump pressures
Air motor doesn’t move with air pres- sure applied
Damaged air valve Replace or service air valve. See Air Motor manual.
Damaged pilot valve Replace valve. See Air Motor man- ual. Park valve left open or leaking
Pump movement speed is erratic Worn air motor seals Replace seals. See Air Motor man- ual.
Worn pump seals Replace seals; see Pump manual.
Plug in power cord.
No power.
Turn disconnect ON .
Display does not illuminate.
Low voltage. Ensure input voltage is within specifi- cations, page 36.
Loose wire. Check connections, page 36.
Display disconnected. Check cable connections, page 36.
Display disconnected. Check cable connections, page 36.
Display cable damaged or corroded. Clean connections; replace cable if is damaged.
Temperature display does not illuminate.
Troubleshooting · Problem Cause Solution

Low voltage. Ensure input voltage is within specifi- cations, page 36.
Poor display connection. Check cable connections, page 36. Replace damaged cable.
Erratic display; display turns on and off.
Display cable damaged or corroded. Clean connections; replace cable if is damaged.
Display cable not grounded. Ground cable, page 37.
Display extension cable too long. Must not exceed 100 ft (30.5 m)
Hose display reads OA at startup. FTS disconnected or not installed. Verify proper installation of FTS (see Operation manual), or adjust FTS to desired current setting.
Poor display connection. Check cable connections, page 36. Replace damaged cable.
Display cable damaged or corroded. Clean connections; replace cable if is damaged.
Display does not respond properly to button pushes.
Ribbon cable on display circuit board disconnected or broken.
Connect cable (page 36) or replace.
Broken display button. Replace, page 36.
No hose heat. Loose hose electrical connections. Check connections. Repair as neces- sary.
Circuit breakers tripped. Reset breakers (CB1 or CB2), page 34.
Hose zone not turned on.
Press zone key.
A and B temperature setpoints too low.
Check. Increase if necessary.
Failed temperature control module. Open cabinet. Check if board LED is blinking. If not, check power wiring connections to ensure module has power. If board has power and LED is not blinking, replace module, page 26.
Low hose heat. A and B temperature setpoints too low.
Increase A and B setpoints. Hose designed to maintain temperature, not increase temperature.
Hose temperature setpoint too low. Check. Increase if necessary to maintain heat.
Flow too high. Use smaller mix chamber. Decrease pressure.
Low current; FTS not installed. Install FTS, see operation manual.
Hose heat zone not turned on long enough.
Allow hose to heat up, or preheat fluid.
Loose hose electrical connections. Check connections. Repair as neces- sary.
Troubleshooting · Problem Cause Solution

Heat turned off.
Primary heater(s) does not heat.
keys.
Temperature control alarm. Check temperature display for diag- nostic code, page 9.
Signal failure from thermocouple. See E04: Fluid Temperature Sen- sor (FTS) or thermocouple discon- nected, page 11.
Control of primary heat is abnormal; high temperature overshoots or E01 error occurs intermittently.
Dirty thermocouple connections. Examine connection of thermocou- ples to long green plug on heater control board. Unplug and re-plug thermocouple wires, cleaning off any debris. Unplug and re-plug long green connector.
Thermocouple not contacting heater element.
Loosen ferrule nut (N), push in ther- mocouple (361) so tip (T) contacts heater element (358). Holding ther- mocouple tip (T) against heater ele- ment, tighten ferrule nut (N) 1/4 turn past tight. See page 30 for illustra- tion.
Failed heater element. See Primary Heater, page 28.
Signal failure from thermocouple. See E04: Fluid Temperature Sen- sor (FTS) or thermocouple discon- nected, page 11.
Thermocouple wired incorrectly. See E04: Fluid Temperature Sen- sor (FTS) or thermocouple discon- nected, page 11. Power up zones one at a time and verify that tempera- ture for each zone rises.
Troubleshooting · Press or zone

Ambient temperature is too cold. Use auxiliary hose heat system.
FTS failed or not installed correctly. Check FTS, page 11.
Hose heats but heats slower than usual or it does not reach tempera- ture.
Low supply voltage. Verify line voltage. Low line voltage significantly reduces power available to hose heat system, affecting longer hose lengths.
A and B setpoints too low. Increase A and B setpoints. Hose is designed to maintain temperature, not to increase it.
Ambient temperature is too cold. Increase A and B setpoints to increase fluid temperature and keep it steady.
Flow too high. Use smaller mix chamber. Decrease pressure.
Hose does not maintain temperature while spraying.
Hose was not fully preheated. Wait for hose to heat to correct tem- perature before spraying.
Low supply voltage. Verify line voltage. Low line voltage significantly reduces power available to hose heat system, affecting longer hose lengths.
A and/or B heaters are overheating material.
Check primary heaters for either a thermocouple problem or a failed ele- ment attached to thermocouple, page 11.
Faulty thermocouple connections. Verify that all FTS connections are snug and that pins of connectors are clean. Examine connection of ther- mocouples to long green plug on heater control board. Unplug and re-plug thermocouple wires, cleaning off any debris. Unplug and re-plug long green connector on heater con- trol board.
Hose temperature exceeds setpoint.
Faulty thermocouple connections. Verify that all FTS connections are snug and that pins of connectors are clean. Examine connection of ther- mocouples to long green plug on heater control board. Unplug and re-plug thermocouple wires, cleaning off any debris. Unplug and re-plug long green connector.
Erratic hose temperature.
FTS not installed correctly. FTS should be installed close to end of hose in same environment as gun. Verify FTS installation, page 32.
Troubleshooting

FTS failed or is not contacting correctly.
Check FTS, page 11.
FTS not installed correctly. FTS should be installed close to end of hose in same environment as gun. Verify FTS installation, page 32.
Hose does not heat.
Temperature control alarm. Check temperature display or diag- nostic code, page 32.
Hoses near Reactor are warm, but hoses downstream are cold.
Shorted connection or failed hose heating element.
With hose heat on and temperature setpoint above displayed hose zone temperature, verify voltage between connectors at each section of hose.
Voltage should drop incrementally for each section of hose further from Reactor. Use safety precautions when hose heat is turned on.
Troubleshooting


Unless otherwise noted, all repair procedures must be completed with incoming power switched OFF and locked out at the source. Any electrical repair or troubleshooting required beyond the scope of this manual must be performed by a qualified electrician. Shut off air inlet ball valve and shut off all air supply pressure.


Air motor shaft, yoke, pump rod and connecting rod move during operation. Moving parts can cause serious injury such as pinching or amputation. Keep hands and fingers away from connecting rod during operation.




a. Install two pipe plugs (324).
b. Reconnect two tubing lines (N) from ISO Pump Lube reservoir. Flush and refill reservoir with TSL 206995.




Air Inlet Filter / Water Separator (Auto Drain)
Valves can be serviced with the block on the machine (see page 46 for parts view). For thorough cleaning, remove the block assembly as follows.



DATA (A) Data reporting
HOSE T/C P; FTS (purple) 12 11 HOSE T/C R; FTS (red) 10 HOSE T/C S; FTS (silver (unshielded bare wire)) 9 HEATER T/C B, Y; Thermocouple (yellow) 8 HEATER T/C B, R; Thermocouple (red) 7 Not used 6 HEATER T/C A, Y; Thermocouple (yellow) 5 HEATER T/C A, R; Thermocouple (red) 4, 3 OVERTEMPERATURE B; Overtemperature switch B 2, 1 OVERTEMPERATURE A; Overtemperature switch A DISPLAY (C) Display COMMUNICATION (D) Communication to power

E
F
G
boards PROGRAM (E) Software programming BOOT (F) Software bootloader POWER/RELAY (G) Circuit board power input and contactor control output
Right Side of Control Heater Module


Communication to control board POWER (J) Power to heater
Bottom of Power Modules
Connector Description

Replacing Temperature Control Assembly Modules
a. Make sure everything is connected, including the hose.
Before handling assembly, put on static conductive wrist strap to protect against static discharge which can damage assembly. Follow instructions provided with wrist strap.
b. Turn main power ON .
c. Adjust the hose heat setpoint above the ambi- ent hose temperature.
d. Turn on heat zone by pressing .
supply.
e. Hold down to view electrical current.
Hose current should ramp up to 45A. If there is no hose current, see E03: No zone current, page 11. If hose current exceeds 45A, see E02: High zone current, page 11. If hose current stays several amps below 45A, hose is too long or voltage is too low.
a. Make sure everything is connected, including the hose.
b. Turn main power ON .
c. Adjust the hose heat setpoint below the ambi- ent hose temperature.
d. Turn on heat zone by pressing .
Using a voltmeter, carefully measure the voltage at the hose connector. You should not get a voltage reading. If you do, the SCR on the temperature control module is bad. Replace the temperature control assembly.

The primary heaters output their rated wattage at 230 Vac. Low line voltage will reduce power available and the heaters will not perform at full capability.
Read Warnings on page 4. Wait for heater to cool before repairing.
supply.
Heater Rod · Element Wattage Ohms · 1500 30-35


Apply sealant and PTFE tape to all non swiveling and threads without o-rings.
Apply lubricant to o-rings.
Orient rupture disc housing (369) with exhaust hole pointing towards the bottom of the heater.
FIG. 7. 6 kW Dual Zone Heater


a. Remove protective tape from thermocouple tip (T).
Read Warnings on page 4. Wait for heater to cool before repairing.
b. Apply PTFE tape and thread sealant to male threads and tighten thermocouple housing (H) into adapter (356).
supply.
c. Push in thermocouple (361) so tip (T) contacts heater element (358).
d. Holding thermocouple (T) against heater ele- ment, tighten ferrule nut (N) 1/4 turn past tight.
Apply PTFE tape and thread sealant. 1

FIG. 8. Thermocouple


Read Warnings on page 4. Wait for heater to cool before repairing.
supply.
supply.


Refer to the heated hose manual for hose replacement parts.
1 to 2 approximately 35 ohms per 50 ft (15.2 m) of hose, plus approximately 10 ohms for FTS
supply.

supply.
The Fluid Temperature Sensor (FTS) is supplied. Install FTS between main hose and whip hose. See Heated Hose manual 309572 for instructions.
1 to 2 approximately 10 ohms
1 to 3 infinity
3 to FTS groundscrew 0 ohms
1 to FTS component A fitting (ISO)

F
W
A
ISO
B
A
H
Pins Result · infinity · ti9581c

310 ft. 90 Vac*
210 ft. 62 Vac*
* For 230 Vac line voltage.
Replace Transformer

supply.
If you are not sure which wire in green plug under hose module connects to transformer, test both wires. One wire should have continuity with the other transformer wire in breaker (909) and the other wire should not.

Model Secondary Voltage

supply. Turn circuit breakers on to test.
a. Refer to electrical diagrams and table below. Disconnect wires and remove bad breaker.
b. Install new breaker and reconnect wires.
Ref. Size Component
CB1 50 A Hose Secondary (single)
CB2 40 A Hose Primary (double)
CB3 25 A Heater A (double)
CB4 25 A Heater B (double)
ti17569a CB1 CB2 CB3 CB4

Check the condition of the ISO pump lubricant daily. Change the lubricant if it becomes a gel, its color dark- ens, or it becomes diluted with isocyanate.
Gel formation is due to moisture absorption by the pump lubricant. The interval between changes depends on the environment in which the equipment is operating. The pump lubrication system minimizes exposure to mois- ture, but some contamination is still possible.
Lubricant discoloration is due to continual seepage of small amounts of isocyanate past the pump packings during operation. If the packings are operating properly, lubricant replacement due to discoloration should not be necessary more often than every 3 or 4 weeks.
RB ti18001a RT ST
To change pump lubricant:
FIG. 13. Pump Lubrication System

Temperature Display
The inlet strainers filter out particles that can plug the pump inlet check valves. Inspect the screens daily as part of the startup routine, and clean as required.
Before handling board, put on static conductive wrist strap to protect against static discharge which can damage assembly. Follow instructions provided with wrist strap.
Isocyanate can crystallize from moisture contamination or from freezing. If the chemicals used are clean and proper storage, transfer, and operating procedures are followed, there should be minimal contamination of the A-side screen.
supply.

B C D Ti10974a
FIG. 14. Fluid Inlet Strainer


Detail of Membrane Switches and Temperature Display Board

FIG. 15. Display Module
102a · Temperature Display · 102b


The battery and fuse must be replaced in a non-hazardous location.
Use only a Graco-approved replacement fuse. Order Part 24C580.



FIG. 18. DataTrak Battery and Fuse Location
Solenoid Cable Connection · Fuse · Sensor Cable Connection

P2 Spray Gun
Pumps, hoses, and mounting hardware to supply fluids to Reactor. Includes 246483 Air Supply Kit. See 309815.
Probler P2 Gun available in round or flat pattern. See 313213.
Y-Strainer Screen
Hoses and fittings to supply air to feed pumps, agitator, and gun air hose. Included in feed pump kits. See 309827.
Replacement strainer screen for fluid Y-strainer; 20 mesh.
Part Description 180199 20 mesh; as shipped 255082 80 mesh (2 pack) 255083 80 mesh (10 pack)
Return hoses and fittings to make circulation system. Includes two 246477 Return Tube Kits. See 309852.
246477 Return Tube Kit
Replacement air filter element; 5 micron.
Desiccant dryer, return tube, and fittings for one drum. Two included in 246978 Circulation Kit. See 309852.
All hardware and wheels to convert model 262572.
206995 1 qt (1 liter) bottle
206996 1 gal. (3.8 liter) container
DataTrack and reed switch for NXT Air Motor. See man- ual 313541.
Keep the following spare parts on hand to reduce down- time.
Part No. Description
50 ft (15.2 m) and 25 ft (7.6 m) lengths, 1/4 in. (6 mm), 3/8 in. (10 mm), or 1/2 in. (13 mm) diameter, 2000 psi (14 MPa, 140 bar) or 3500 psi (24 MPa, 241 bar). See 309572.
262648 Pump, Resin (B) side
246421 Resin (B) Pump Repair Kit for 262648 pump
262647 Pump, ISO (A) side
15C851 ISO (A) Pump Repair Kit for 262647 pump
10 ft (3 m) whip hose, 1/4 in. (6 mm) or 3/8 in. (10 mm) diameter, 2000 psi (14 MPa, 140 bar) or 3500 psi (24 MPa, 241 bar). See 309572.
246963 Wet Cup Kit for 262647 pump
206995 TSL bottle, 1 qt (1 liter)
101078 Y-Strainer; includes 180199 element
180199 Element, Y-Strainer, 20 mesh
114228 Element, air filter, 5 micron
Air Purge Gun available in round or flat pattern. See 309550. Mechanical Purge Gun available in round or flat pattern. See manual 309856. Clear Shot Gun available in round or flat patter. See manual 312666.
239914 Valve, recirc/spray; includes seat and gasket
Accessories


Parts · 91, 92 · 90 (x6)


Torque pump locking nuts to 66-74 ft-lbs (90-100 N•m).
Apply anaerobic polyacrylate pipe sealant to all non-swiveling pipe threads.
Torque tube ends to 212-265 in-lbs (24-30 N•m).
Connect ground wire (94) from motor lug to ground lug in cabinet.
Parts · 9 (x4) · 63 13 (x2)


9 111799 SCREW, cap, hex hd; M8 x 1.25 8 10 108296 SCREW, mach, hex wash hd; 1/4-20 UNC-2A 4
Ref Part Description Qty.
1 --- CART 1 2 262573 PUMP; see page 48 1 3 262577 MANIFOLD, relief; see page 46 1 4 --- PANEL, control, heater; see page 45
11 125621 SCREW, machine, hex washer, hd; M6 x 1
12 16G917 BRACKET, heater 1 13 114182 SCREW, mach, hex flange; M6 x 1
5 24J788 HEATER, system, (6.0kw, 230v); see page 47 1
6 262575 PANEL, control; see page 44 1 7 262576 MODULE, breaker; see page 50 1 8 24M177 TRANSFORMER, 2790va, 230/62 1
14 117623 NUT, cap, 3/8-16 4 15 106084 SCREW, mach, pan hd; M5 x 0.8 2
16 117682 BUSHING, strain relief 1
Parts · 13 (x4)

17 123970 SWITCH, disconnect, 40a 1 18 123971 KNOB, disconnect, operator 1 19 123972 SWITCH, fourth pole 1 20 205447 COUPLING, hose 2 21 16G921 TUBE, fluid, A, heater, inlet 1 22 16G922 TUBE, fluid, A, heater, outlet 1 23 16G923 TUBE, fluid, B, heater, inlet 1 24 16G924 TUBE, fluid, B, heater, outlet 1 25 112125 PLUG, tube 2 26 117666 TERMINAL, ground 1 27 15D795 FILTER, air, 40 micron 1 28 107128 TEE, service 1 29 114110 ELBOW, male, swivel 1 30 162449 NIPPLE, reducing 1 31 158491 NIPPLE 1 32 262660 VALVE, ball, 1/2 npt x 1/2 npt 1 33 114269 GROMMET, rubber 4 34 16G918 COVER, heater 1 35 246995 BOTTLE, assembly, complete 1 36 234366 KIT, fluid inlet, pair; see page 46 1 37† 262695 KIT, wheel; see page 51 2 38 16M152 BRACKET, lube, reservoir 1 44‡ 247791 HARNESS, wire, hose 1 45‡ 261669 KIT, fluid temp sensor, coupler 1 49 167002 INSULATOR, heat 2 50 16J433 HARNESS, wire, display, ext. 1 51 16J434 HARNESS, over temp, a-side, b-side
69† --- FASTENER, screw, pan head, m4 x 35mm
79 262581 COVER, electrical, assembly 1 80 --- SCREW, shcs, m5x60 2 83 248208 HOSE, coupled, 4 feet 1 82‡ 15H187 WIRE, jumper, w/quick discon- nect
84 --- LABEL, product 1 85 16J808 LABEL, warning, disconnect wiring
88 195874 SCREW, phillips, pan hd; M4 x 8 1 89 16K669 FILTER, electrical 3 90 115266 SCREW, cap, socket hd; M5 x 10 6
91 --- SCREW, pan hd; M5 x 16 1 92 --- WASHER, #10, external tooth lock
93 --- TUBE, pe, spiral, wrapping; 1.2 ft (0.4 m)
94 16M086 WIRE, ground, pump 1 95‡ 114601 CONDUIT, flexible, non-metallic 1 96‡ --- SLEEVE, heat-shrink, 2:1; 0.75 ft, 1/2 in. ID, 1/4 in. OD
97‡ 120573 BRIDGE, plug-in, jumper 4 98 16M088 LABEL, error codes 1 99‡ 114958 STAP, tie 10 100 105676 SCREW, pan hd 4
Replacement Danger and Warning labels, tags, and
cards are available at no cost.
52 261821 CONNECTOR, wire, 6awg 1 53‡ --- FLUID, oxide inhibitor 1 54‡ 206994 FLUID, TSL, 8 oz. bottle 1 55‡ 206995 FLUID, TSL, 1 qt. 1 56 186494 CLIP, spring 4 57 --- HOSE, PTFE; 5 ft (1.5 m), 0.25 in. (6.35 mm) ID
† Only used with 262614.
Only used with 262572.
Included in Reed Switch Kit 24B659.
‡ Not shown.
58 15G280 LABEL, warning 1 59 189930 LABEL, caution 1 60 189285 LABEL, caution 3 61 15H108 LABEL, pinch point 1 62 15B380 CABLE, hose, control 1 63 16G952 COVER, pump 2 64 --- TUBE, polyethylene, rnd; 3/4 OD; 0.75 ft (0.2 m); see page 49
65 --- TUBE, polyurethane, rnd, black; 5.12 ft (1.56 m); see page 49 1
66 --- INSERT, control panel 2 67† 24B563 KIT, DataTrak 1 68†24B659 SWITCH, reed assy 1
Parts


Apply sealant to all non swiveling pipe threads.
Attach ground wire from harness (116) between connector on harness (106) and display cover (105).
Attach harness (106) to J13 on board (102).
Attach harness (119) to J1 on board (102).
112 16F810 NUT, regulator, steel 1 113 114114 FITTING, elbow, male, swivel 4 114 114362 VALVE, ball, air 1 115 110637 SCREW, mach, pan head 2 116 331342 SCREW, screw 10-24 x1/2 in. ph pn hd
Ref. Part Description Qty. 101 16G912 PLATE, display 1 102 24G883 DISPLAY, temperature; includes 102a-102c 1
102a 24G882 BOARD, circuit 1 102b 246478 SWITCH, membrane 1 102c 112324 SCREW 4 103 117523 NUT, cap (#10) 8 104 16G958 GASKET, display cover 1 105 16G913 COVER, display 1 106 16J432 HARNESS, wire, display 1 107 --- SCREW, pan head, phillips 2 108 116257 GAUGE, pressure 1 109 100451 COUPLING, 1/8 npt 1 110 114151 FITTING, elbow, male, swivel 1 111 15T536 REGULATOR, air, 3/8 npt 1
117 114469 FITTING, elbow, m swivel 1 118 116643 VALVE, relief, air, 90 psi (620.5 kPa)
119 16J431 HARNESS, jumper, heater dis- play
121 16K525 LABEL, control 1
Parts



To B Heater Module
To A Heater Module
To Hose Heater Module Ref. Part Description Qty.
191† 16H182 AXLE, wheel 2 192† 111841 WASHER, plain 5/8 4 193† 191824 WASHER, space 4 194† 101242 RING, retaining, ext. 4 195† 16G920 WHEEL, semi pneumatic, offset 2
Ref. Part Description Qty. 151 16G925 PANEL, pod, mounting 1 152 247827 MODULE, heater control 1 153 247828 MODULE, heater 3 154 114183 NUT, hex, flanged, serrated 4 155 247801 CABLE, communication 1
† Only used with 262614. Available as add on wheel kit 262695.



Assemble ball valves in orientation shown.
Apply anaerobic polyacrylate pipe sealant to all NPT connections.
Apply sealant and torque to 250 in-lbs (28 N•m). 1
Ref. Part Description Qty.
Use blue thread lock on valve cartridge threads into manifold. 2
251 160327 UNION, adapter, 90°; 3/4 npt(m) x 3/4-14 npt(f) 2
Part of item 208. 3
Apply lubricant to mating surfaces. 4
252 101078 Y-STRAINER; 20 m screen 2 253 C20487 NIPPLE, 3/4 npt 2 254 109077 VALVE, ball; 3/4 npt (fbe) 2 255 118459 UNION, swivel; 3/4-14 npt(m)x 3/4-14 npt(f) 2
Apply pipe sealant to all NPT threads. 5
Ref. Part Description Qty. 201 24K993 MANIFOLD, recirculation 1 202 108638 FITTING, pipe, tee 2 203 162453 FITTING, (1/4 npsm x 1/4 npt) 2 204 113641 GAUGE, pressure, fluid, SST 2 205 111600 PIN, grooved 2 206 119789 FITTING, elbow, street, 45 deg, 2 207 116704 ADAPTER, 3/8 JIC x 1/4 npt 1 208 239914 VALVE, drain; includes 208a, 208b 2 208a --- SEAT 2 208b --- GASKET 2 209 119998 ADAPTER, 5/16 JIC x 1/4 npt 1 210 116702 FITTING, union, 1/4 npt x 3/8 JIC 2 212 187625 HANDLE, valve, drain 2 213189285 LABEL, caution 1 214 224807 BASE, valve 2
256 180199 ELEMENT, 20 mesh 2
Replacement Danger and Warning labels, tags, and
cards are available at no cost.
Parts


Apply sealant and PTFE tape to all non swiveling and threads without o-rings.
Apply lubricant to o-rings.
Orient rupture disc housing (369) with exhaust hole pointing towards the bottom of the heater.
359 15B137 SWITCH, over temperature 1 360 15B135 MIXER, immersion heater 4 361 117484 SENSOR 2 362 --- SCREW, mach, pnh 2 369 247520 KIT, rupture disc 2
Ref Part Description Qty.
351 --- HEATER, dual zone 1 352 124132 O-RING 4 353 15H305 FITTING, plug hollow hex 1-3/16 sae 4
354 121309 FITTING, adapter, sae-orb x jic
355 15H304 FITTING, plug 9/16 sae 2 356 15H306 ADAPTER, thermocouple, 9/16 x 1/8 2
357 120336 O-RING, packing 2 358 16A112 HEATER, immersion, (1500w, 230v) 4
Parts


Ref Part Description Qty.
301 16G915 PLATE, Mounting, Cylinder 1 302 193031 NUT, retaining 2 303 262647 PUMP, displacement, w/lube; iso 1 304 262648 PUMP, displacement; resin 1 305 15J132 LINK, connecting 2 306 183210 PIN, str, hdls 2 307 183169 SPRING, retaining 2 308 M12LP0 MOTOR, air, NXT, 6 in., cycle
only; see manual 312796
309 16G929 ROD, tie 4 310 125266 NUT, lock, nylon, m12 4 311 16G926 BRACKET, pump mounting 1 312 117833 ADAPTER, 3/4-16 JIC x 3/8 NPT 2 313 120553 NUT, center lock, 5/8-18 3 314 111799 SCREW, cap, hex hd 4 315 16G914 ADAPTER, rod 1 316 114110 ELBOW, male, swivel 1 317 15K783 ELBOW, street, 90° 1 318 116746 FITTING, barbed, plated 2 319 16G916 PLATE, yoke, pump 1 322 15H108 LABEL, pinch point 1 324 100139 PLUG, PIPE 2 325 15B565 VALVE, 1/4 npt, park 1
Apply PTFE tape and sealant to non-swiveling pipe threads.
Torque to 32-38 ft-lbs (43-51 N•m). Torque nut (313) after assembly of item pin (306) and spring (307).
Install adapters so that pins (306) will be in-line with each other.
Lubricate threads of pump cylinders (303, 304) and plate (301) with lubricant prior to assembly into mounting plate. Assemble pump cylinder 1/2 thread above flush to one and one half thread above flush of mounting pate surface.
Torque to 27-32 ft-lbs (37-43 N•m).
Use blue thread lock (medium).
Parts


Outside Diameter From To 64 0.75 ft (0.23 m) 503 503 UHMWPE Black 5/32 in. (4 mm) 65 2.66 ft (0.8 m) 501 501 Urethane Black 1/2 in. (12.7 mm) 65 1.66 ft (0.5 m) 502 502 Urethane Black 1/2 in. (12.7 mm) 65 0.75 ft (0.23 m) 500 500 Urethane Black 1/2 in. (12.7 mm)
Parts


Ref. Part Description Qty.
401 16H309 RAIL, mounting 1 402 112446 BLOCK, clamp end 1 403 120490 COVER, end 3 404 120570 BLOCK, terminal 15 405 255046 BLOCK, terminal ground 1 406 255050 CIRCUIT BREAKER, 25a, 2p 2 407 24M176 CIRCUIT BREAKER, 30a, 2p 1 408 255026 CIRCUIT BREAKER, 1 pole, 50a, c curve 1
409 255022 RELAY, contactor, 65a, 3p 1 410 120491 BLOCK, terminal 4 411 255043 HOLDER, fuse term.block 5x20mm 2
412 255023 FUSE, 5a, 5x20mm 2 413 120573 BRIDGE, plug-in, (jumper) 2 414 120485 BRIDGE, plug-in, (jumper) 2 415 16J534 HARNESS, wiring 1
Parts

Reactor A-25 Wiring Schematic

3 PHASE 230V DELTA 3 PHASE 230V 1 PHASE

Reactor A-25 Wiring Schematic

12 + 11 - 10 GROUND 9 + 8 - 7 NOT USED 6 + 5 - 4 NOT USED 3 NOT USED 2 OVERTEMP A
5 COMMON 4 COMMON 3 A 2 B 1 +12V
180 181 182 183 184 185 186 187 188 189 190

Reactor A-25 Wiring Schematic

1 3 1 3 1 3 1
2 183CB 50A 178CB 30A 187CB 25A 197CB 25A

Reactor A-25 Wiring Schematic

2 183CB 50A 178CB 30A 187CB 25A 197CB 25A

Category Data Maximum Fluid Working Pressure 2000 psi (14 MPa, 138 bar) Maximum Air Supply Pressure 125 psi (0.9 MPa, 9 bar) Maximum Air Working Pressure 80 psi (550 kPa, 5.5 bar) Pressure Ratio 25:1 Air consumption with 02 tip at 1500 psi stall pres- sure
28 scfm (0.8m3/min)
Machine Maximum Power with hose 9000 Watts Voltage Requirement (50/60 Hz)
230 V, 1 Phase 230 V, 3 Phase (Delta) 380 V, 3 Phase (WYE 220 V to Neutral) Amperage Requirement (Full Load Peak)* 40 amps @ 230 V, 1 Phase 32 amps @ 230 V, 3 Phase 18.5 amps @ 380 V, 3 Phase Maximum Heater Fluid Temperature 190 °F (88 °C) Maximum Hose Fluid Temperature 180 °F (82 °C) Maximum Ambient Temperature 120 °F (49 °C) Maximum Output 25 lb/min. (11.4 kg/min.) Output Per Cycle (A and B) 0.025 gal/cycle (0.095 ltr/cycle) Heater Power 6000 Watts Hose Power 2790 Watts Sound Pressure (see NXT air motor manual) 70.2 dB(A) Sound Power (see NXT air motor manual) 80.1 dB(A) Viscosity Range 250-1500 centipoise (typical) Maximum Fluid Inlet Pressure 300 psi (2.1 MPa, 21 bar) or 15% of output pressure Fluid Inlet/Strainer Filter 20 mesh standard Air inlet Filter Mesh 40 Micron Component B (Resin) Inlet 3/4 npt(f) swivel Component A (Isocyanate) Inlet 3/4 npt(f) swivel Recirculation/Block Hose Connections Iso (A) side: #5 JIC (m); Resin (B) side: #6 JIC (m) Maximum Heated Hose Length*** 210 ft of 3/8 ID Weight 310 lb (140.6 kg) Wetted Parts Carbon steel, stainless steel, chrome, aluminum, Fluoroelastomer, PTFE, nylon
*Full load amps with all devices operating at maximum capabilities with 210 ft (64.1 m) of hose.
***210 ft (64 m) of heated hose will produce the maximum allowable heat capacity. 310 ft (94 m) of heated hose may be used, but will have 25% less heat capacity.
Technical Data

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 3A1750
Copyright 2011, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Pages referenced in this manual — manufacturer, support and downloads.
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| E01 | High fluid temperature . . . . . . . . . . . . . . . 10 | p.2 | |
| E02 | High zone current . . . . . . . . . . . . . . . . . . . 11 | p.2 | |
| E03 | No zone current . . . . . . . . . . . . . . . . . . . . 11 | p.2 | |
| E04 | Fluid Temperature Sensor (FTS) or | p.2 | |
| E05 | Control board over temperature . . . . . . . . 12 | p.2 | |
| E06 | Communication cable unplugged . . . . . . . 12 | p.2 | |
| E30 | Momentary loss of communication . . . . . . 12 | p.2 | |
| E99 | Loss of communication . . . . . . . . . . . . . . . 12 | p.2 | |
| E-2 | Leak during downstroke. | p.9 | |
| E-3 | Battery voltage too low to stop runaway. | p.9 | |
| E-6 | Fuse is blown. Replace fuse; see page 38. | p.9 |
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Heat zones do not operate | No power | Connect power cord | p.15 |
| Heat zones do not operate | Turn Main Disconnect Switch ON | p.15 | |
| Heat zones do not operate | Power cord not connected properly | Check connections | p.15 |
| No power when disconnect switch is turned on; using 230V, 1 phase or 230V, 3 phase power | Power terminal jumper still at 380V, 3 phase position, as shipped from fac- tory | Place jumpers in correct position; see Operation manual and label inside front lower cabinet. | p.15 |
| External main supply power circuit breaker trips and Reactor disconnect switch fails when switch is turned on. | Power terminal jumper was left in 230V, 1 phase position. When using 230V, 3 phase or 380V, 3 phase power | Place jumpers in correct position; see Operation manual. Replace main power disconnect switch; see page 40. | p.15 |
| No temperature display lights at startup | No power | Connect power cord | p.15 |
| No temperature display lights at startup | Turn Main Disconnect Switch ON | p.15 | |
| No temperature display lights at startup | Control power fuses blown | Check and replace fuses on long ter- minal strip | p.15 |
| Pump does not run up and down | Motor control valve closed | Open air motor shutoff valve | p.15 |
| Pump does not run up and down | No air supply | Air supply line not connected | p.15 |
| Pump does not run up and down | Open inlet air ball valve | p.15 | |
| Pump does not run up and down | Air pressure regulators set at 0 psi | Turn up air pressure regulators | p.15 |
| Pump does not run up and down | Air motor shuttle valve is centered. | Push button on top of air motor shut- tle valve. | p.15 |
| Pump runs but no fluid pressure | Fluid inlet ball valves closed | Open fluid inlet ball valves | p.15 |
| Fluid pressure low or dropping | Air supply pressure low when spray- ing | Increase inlet air pressure | p.16 |
| Fluid pressure low or dropping | Increase air compressor size to meet flow requirements | p.16 | |
| Fluid pressure low or dropping | Remove airline quick disconnects | p.16 | |
| Fluid pressure low or dropping | Use 3/8 in. (0.95 cm) ID or larger air supply hose. Use 1/2 in. (12.7 mm) if longer than 25 ft (7.6 m). | p.16 | |
| Fluid pressure low or dropping | Icing in air motor exhausts or mufflers | Check inlet filter water separator; see page 25. Stop spraying while ice melts. | p.16 |
| Pump output low, but pressure is nor- mal | Obstructed gun impingement ports or filters | Flush and clean gun; see gun manual | p.16 |
| One pressure gauge drops when pumps are stalled on both the upstroke and the downstroke | Leaking pump throat | Repair pump; see 309577 | p.16 |
| One pressure gauge drops when pumps are stalled on both the upstroke and the downstroke | Leak between pump and gun | Check fluid tubes, heater, and hoses | p.16 |
| One pressure gauge drops when pumps are stalled on both the upstroke and the downstroke | Pressure Relief/Spray valve leaking back to supply | p.16 | |
| One pressure gauge drops when pumps are stalled on both the upstroke and the downstroke | Spray gun is leaking on one side or plugged on the other side | Clean and repair spray gun | p.16 |
| One pressure gauge drops when pumps are stalled on the downstroke, but not the upstroke | Inlet ball check not sealing | Clean or replace; see 309577 | p.16 |
| One pressure gauge drops when pumps are stalled on the downstroke, but not the upstroke | Inlet check seat o-ring not sealing | Repair pump; see 309577 | p.16 |
| One pressure gauge drops when pumps are stalled on the upstroke, but not the downstroke | Piston check ball not sealing | Repair pump; see 309577 | p.16 |
| One pressure gauge drops when pumps are stalled on the upstroke, but not the downstroke | Piston packing not sealing | Repair pump; see 309577 | p.16 |
| One pressure gauge drops when pumps are stalled on the upstroke, but not the downstroke | Loose piston stud in pump | Repair pump; see 309577 | p.16 |
| One pressure gauge drops when pumps are stalled on the upstroke, but not the downstroke | Bad inside sleeve seal | Repair o-ring; see 309577 | p.16 |
| A side rich; lack of B side | A side gauge is low | B side restriction downstream of gauge. Check gun check valve screen, mix module, or mix manifold restrictor. | p.16 |
| A side rich; lack of B side | A side impingement port is worn. | p.16 | |
| A side rich; lack of B side | B side gauge is low | B side material supply problem. Check B side inlet strainer and pump intake valve. | p.16 |
| B side rich; lack of A side | A side gauge is low | A side material supply problem. Check A side inlet strainer and pump intake valve. | p.16 |
| B side rich; lack of A side | B side gauge is low | A side restriction downstream of gauge. Check gun check valve screen, mix module, or mix manifold restrictor. | p.16 |
| B side rich; lack of A side | B side impingement port is worn. | p.16 | |
| Fluid pressures not balanced between A and B side | Fluid viscosities not equal | Adjust A and B temperature settings to balance viscosity. Sometimes nor- mal if pressure offset is below 200 psi (14 bar) | p.17 |
| Fluid pressures not balanced between A and B side | Preheat material in drums by recircu- lating; see Operation manual | p.17 | |
| Fluid pressures not balanced between A and B side | Inlet Y-strainer screen plugged on low pressure side | Clean inlet filter screen | p.17 |
| Fluid pressures not balanced between A and B side | Gun port or filter plugged on high pressure side | Clean or replace; see gun manual | p.17 |
| Fluid pressures not balanced between A and B side | Pump inlet ball not seating or sticking | Clean seating; see pump manual | p.17 |
| Fluid pressures not balanced between A and B side | Drum fluid outlet supply hose too small | Use 3/4 in. (1.9 cm) ID hose with short length | p.17 |
| Fluid pressures not balanced between A and B side | Low side feed pump not working | Turn on or repair feed pump | p.17 |
| Fluid pressures not balanced between A and B side | Pressure Relief/Spray valve leaking back to supply | p.17 | |
| Pump does not reverse direction | Obstruction of air motor or pumps | Check and clear obstruction | p.17 |
| Unequal fluid pressure between UP/DOWN stroke | Feed pumps boost pressure on up stroke. | Reduce feed pump pressures | p.17 |
| Air motor doesn’t move with air pres- sure applied | Damaged air valve | Replace or service air valve. See Air Motor manual. | p.17 |
| Air motor doesn’t move with air pres- sure applied | Damaged pilot valve | Replace valve. See Air Motor man- ual. | p.17 |
| Air motor doesn’t move with air pres- sure applied | Park valve left open or leaking | p.17 | |
| Pump movement speed is erratic | Worn air motor seals | Replace seals. See Air Motor man- ual. | p.17 |
| Pump movement speed is erratic | Worn pump seals | Replace seals; see Pump manual. | p.17 |
| Display does not illuminate. | No power. | Plug in power cord. Turn disconnect ON . | p.17 |
| Display does not illuminate. | Low voltage. | Ensure input voltage is within specifi- cations, page 36. | p.17 |
| Display does not illuminate. | Loose wire. | Check connections, page 36. | p.17 |
| Display does not illuminate. | Display disconnected. | Check cable connections, page 36. | p.17 |
| Temperature display does not illuminate. | Display disconnected. | Check cable connections, page 36. | p.17 |
| Temperature display does not illuminate. | Display cable damaged or corroded. | Clean connections; replace cable if is damaged. | p.17 |
| Erratic display; display turns on and off. | Low voltage. | Ensure input voltage is within specifi- cations, page 36. | p.18 |
| Erratic display; display turns on and off. | Poor display connection. | Check cable connections, page 36. Replace damaged cable. | p.18 |
| Erratic display; display turns on and off. | Display cable damaged or corroded. | Clean connections; replace cable if is damaged. | p.18 |
| Erratic display; display turns on and off. | Display cable not grounded. | Ground cable, page 37. | p.18 |
| Erratic display; display turns on and off. | Display extension cable too long. | Must not exceed 100 ft (30.5 m) | p.18 |
| Hose display reads OA at startup. | FTS disconnected or not installed. | Verify proper installation of FTS (see Operation manual), or adjust FTS to desired current setting. | p.18 |
| Display does not respond properly to button pushes. | Poor display connection. | Check cable connections, page 36. Replace damaged cable. | p.18 |
| Display does not respond properly to button pushes. | Display cable damaged or corroded. | Clean connections; replace cable if is damaged. | p.18 |
| Display does not respond properly to button pushes. | Ribbon cable on display circuit board disconnected or broken. | Connect cable (page 36) or replace. | p.18 |
| Display does not respond properly to button pushes. | Broken display button. | Replace, page 36. | p.18 |
| No hose heat. | Loose hose electrical connections. | Check connections. Repair as neces- sary. | p.18 |
| No hose heat. | Circuit breakers tripped. | Reset breakers (CB1 or CB2), page 34. | p.18 |
| No hose heat. | Hose zone not turned on. | Press zone key. | p.18 |
| No hose heat. | A and B temperature setpoints too low. | Check. Increase if necessary. | p.18 |
| No hose heat. | Failed temperature control module. | Open cabinet. Check if board LED is blinking. If not, check power wiring connections to ensure module has power. If board has power and LED is not blinking, replace module, page 26. | p.18 |
| Low hose heat. | A and B temperature setpoints too low. | Increase A and B setpoints. Hose designed to maintain temperature, not increase temperature. | p.18 |
| Low hose heat. | Hose temperature setpoint too low. | Check. Increase if necessary to maintain heat. | p.18 |
| Low hose heat. | Flow too high. | Use smaller mix chamber. Decrease pressure. | p.18 |
| Low hose heat. | Low current; FTS not installed. | Install FTS, see operation manual. | p.18 |
| Low hose heat. | Hose heat zone not turned on long enough. | Allow hose to heat up, or preheat fluid. | p.18 |
| Low hose heat. | Loose hose electrical connections. | Check connections. Repair as neces- sary. | p.18 |
| Primary heater(s) does not heat. | Heat turned off. | A B Press or zone keys. | p.19 |
| Primary heater(s) does not heat. | Temperature control alarm. | Check temperature display for diag- nostic code, page 9. | p.19 |
| Primary heater(s) does not heat. | Signal failure from thermocouple. | See E04: Fluid Temperature Sen- sor (FTS) or thermocouple discon- nected, page 11. | p.19 |
| Control of primary heat is abnormal; high temperature overshoots or E01 error occurs intermittently. | Dirty thermocouple connections. | Examine connection of thermocou- ples to long green plug on heater control board. Unplug and re-plug thermocouple wires, cleaning off any debris. Unplug and re-plug long green connector. | p.19 |
| Control of primary heat is abnormal; high temperature overshoots or E01 error occurs intermittently. | Thermocouple not contacting heater element. | Loosen ferrule nut (N), push in ther- mocouple (361) so tip (T) contacts heater element (358). Holding ther- mocouple tip (T) against heater ele- ment, tighten ferrule nut (N) 1/4 turn past tight. See page 30 for illustra- tion. | p.19 |
| Control of primary heat is abnormal; high temperature overshoots or E01 error occurs intermittently. | Failed heater element. | See Primary Heater, page 28. | p.19 |
| Control of primary heat is abnormal; high temperature overshoots or E01 error occurs intermittently. | Signal failure from thermocouple. | See E04: Fluid Temperature Sen- sor (FTS) or thermocouple discon- nected, page 11. | p.19 |
| Control of primary heat is abnormal; high temperature overshoots or E01 error occurs intermittently. | Thermocouple wired incorrectly. | See E04: Fluid Temperature Sen- sor (FTS) or thermocouple discon- nected, page 11. Power up zones one at a time and verify that tempera- ture for each zone rises. | p.19 |
| Hose heats but heats slower than usual or it does not reach tempera- ture. | Ambient temperature is too cold. | Use auxiliary hose heat system. | p.20 |
| Hose heats but heats slower than usual or it does not reach tempera- ture. | FTS failed or not installed correctly. | Check FTS, page 11. | p.20 |
| Hose heats but heats slower than usual or it does not reach tempera- ture. | Low supply voltage. | Verify line voltage. Low line voltage significantly reduces power available to hose heat system, affecting longer hose lengths. | p.20 |
| Hose does not maintain temperature while spraying. | A and B setpoints too low. | Increase A and B setpoints. Hose is designed to maintain temperature, not to increase it. | p.20 |
| Hose does not maintain temperature while spraying. | Ambient temperature is too cold. | Increase A and B setpoints to increase fluid temperature and keep it steady. | p.20 |
| Hose does not maintain temperature while spraying. | Flow too high. | Use smaller mix chamber. Decrease pressure. | p.20 |
| Hose does not maintain temperature while spraying. | Hose was not fully preheated. | Wait for hose to heat to correct tem- perature before spraying. | p.20 |
| Hose does not maintain temperature while spraying. | Low supply voltage. | Verify line voltage. Low line voltage significantly reduces power available to hose heat system, affecting longer hose lengths. | p.20 |
| Hose temperature exceeds setpoint. | A and/or B heaters are overheating material. | Check primary heaters for either a thermocouple problem or a failed ele- ment attached to thermocouple, page 11. | p.20 |
| Hose temperature exceeds setpoint. | Faulty thermocouple connections. | Verify that all FTS connections are snug and that pins of connectors are clean. Examine connection of ther- mocouples to long green plug on heater control board. Unplug and re-plug thermocouple wires, cleaning off any debris. Unplug and re-plug long green connector on heater con- trol board. | p.20 |
| Erratic hose temperature. | Faulty thermocouple connections. | Verify that all FTS connections are snug and that pins of connectors are clean. Examine connection of ther- mocouples to long green plug on heater control board. Unplug and re-plug thermocouple wires, cleaning off any debris. Unplug and re-plug long green connector. | p.20 |
| Erratic hose temperature. | FTS not installed correctly. | FTS should be installed close to end of hose in same environment as gun. Verify FTS installation, page 32. | p.20 |
| Hose does not heat. | FTS failed or is not contacting correctly. | Check FTS, page 11. | p.21 |
| Hose does not heat. | FTS not installed correctly. | FTS should be installed close to end of hose in same environment as gun. Verify FTS installation, page 32. | p.21 |
| Hose does not heat. | Temperature control alarm. | Check temperature display or diag- nostic code, page 32. | p.21 |
| Hoses near Reactor are warm, but hoses downstream are cold. | Shorted connection or failed hose heating element. | With hose heat on and temperature setpoint above displayed hose zone temperature, verify voltage between connectors at each section of hose. Voltage should drop incrementally for each section of hose further from Reactor. Use safety precautions when hose heat is turned on. | p.21 |