Dyna-Star ® HP Vent Valve Kit

EN

Used with the Dyna-Star HP or HF Pump to reduce system pressure and allow injector to reset. For professional use only.

Part No.: 77X540

Maximum Working Pressure3500 psi (241 bar, 24 MPa)
Graco LineLazer V 200HS (77X540) — Part No.: 77X540 diagram (page 1)
Fig. 1 · Part No.: 77X540
Page 2 of the Graco LineLazer V 200HS (77X540) user manual — SKIN INJECTION HAZARD
Page 2 · click to enlarge
Page 2

Warnings

Installation

See the Dyna-Star HF and HP Pump Instruction manual for additional warnings.

Pressure Relief

Follow the Pressure Relief Procedure whenever you see this symbol.

Graco LineLazer V 200HS (77X540) — Pressure Relief diagram (page 2)
Fig. 2 · Pressure Relief

SKIN INJECTION HAZARD

High-pressure fluid from dispense device, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or servicing the equipment.

Follow Pressure Relief Procedure in this manual, when you stop dispensing and before cleaning, check- ing, or servicing equipment.

PRESSURIZED EQUIPMENT HAZARD Over-pressurization can result in equipment rupture and serious injury.

To relieve pressure in the system, use two wrenches working in opposite directions on pump outlet fitting to slowly loosen fitting only until fitting is loose and no more lubricant or air is leaking from fitting as shown in FIG. 1.

  • A pressure relief valve is required at each pump outlet.
  • Follow Pressure Relief Procedure in this manual before servicing.
Graco LineLazer V 200HS (77X540) — SKIN INJECTION HAZARD diagram (page 2)
Fig. 3

PRESSURIZED ALUMINUM PARTS HAZARD Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage.

  • Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents.
  • Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier for compatibility.
Page 3 of the Graco LineLazer V 200HS (77X540) user manual — F IG . 2
Page 3 · click to enlarge
Page 3

Vent Valve Installation

5. Loosen, remove and discard the 3 socket head cap screws (b) from the adapter block (a) (F IG . 3).
Graco LineLazer V 200HS (77X540) — Vent Valve Installation diagram (page 3)
Fig. 4 · Vent Valve Installation

Reference numbers used in these instructions corre- spond to Parts included in Kit and are provided on page 5. Parts identified with an alpha character are user pro- vided or already installed components.

To ensure the correct pressure relief valve is used and pressure settings are correct, always use new parts included in your Vent Valve Kit for reassembly.

1. If unit has already been in service, relieve pressure (see Pressure Relief procedure, page 2).

F IG . 3

6. Remove adapter block (a) and o-rings (c) (F IG . 3). Discard these parts according to state and local codes for proper disposal. These parts will not be used for reassembly.
2. Disconnect Dyna-Star HP or HF pump from main power source.
3. Remove outlet tubing from port marked “0” on the pump adapter block (a) (F IG . 2).
7. Grease o-rings (8) and install o-rings in vent valve block as shown in F IG . 4.
Graco LineLazer V 200HS (77X540) — F IG . 3 diagram (page 3)
Fig. 5
Graco LineLazer V 200HS (77X540) — F IG . 3 diagram (page 3)
Fig. 6

F IG . 4

Clean surface of the Dyna-Star pump outlet with a clean dry cloth. Inspect pump surface for scratches or nicks. A scratched surface can result in fluid leakage.

F IG . 2

4. Remove plug or inlet tubing from port marked “1” on the pump adapter block (a) (F IG . 2).

a · b · a

Page 4 of the Graco LineLazer V 200HS (77X540) user manual — NOTE:
Page 4 · click to enlarge
Page 4
8. Install vent valve (1) to pump surface using the 3 cap screws (4) included in the kit (F IG . 5). Hold the vent valve tight to the surface of the pump to ensure o-rings stay in place during installation.Torque screws to 17-19 ft-lbs (23-26 N.m).
11. Connect cable (d) to valve cartridge (c) (F IG . 7).
Graco LineLazer V 200HS (77X540) — Instructions diagram (page 4)
Fig. 7 · Instructions
Graco LineLazer V 200HS (77X540) — Instructions diagram (page 4)
Fig. 8 · Instructions

F IG . 7

12. Install other end of cable (d) to solenoid control device.

F IG . 5

NOTE:

9. Install lubrication line to vent valve pump outlet port marked “0” (F IG . 6).
  • Cable (d) is available from Graco. See Accessories, page 5 for a list of available cables.
  • Connector termination is a Deutsch DT-04-2P.
Graco LineLazer V 200HS (77X540) — F IG . 5 diagram (page 4)
Fig. 9
  • Solenoid inputs are not polarity dependent. Voltage can be applied in either direction.
  • Solenoid should be activated when the pump is running. See wiring diagrams in pump manual for more details.
13. Reconnect pump to main power supply.
14. Test system to ensure proper operation.

F IG . 6

10. In the inlet port marked “1” (F IG . 6) install either:
  • a plug (10).
  • inlet plumbing necessary to attach a fill pump.

NOTE:

  • For tube-in-tube pump models, the “1” inlet can be used as a fill port.
  • For models equipped with a follower plate, without a tube-in-tube, the “1” inlet deposits grease on top of the follower plate.

d

Page 5 of the Graco LineLazer V 200HS (77X540) user manual — Technical Data
Page 5 · click to enlarge
Page 5

Parts

RefDescriptionQty 1MANIFOLD, electric vent valve1 2VALVE, cartridge, 24VDC1 3VALVE, pressure relief, 3500 psi1 4SCREW, cap, socket, M8 x 1.253 8O-RING2 9PLUG, pipe, 1/8 in. npt1 10PLUG, 1/4 in. npt1
Graco LineLazer V 200HS (77X540) — Parts diagram (page 5)
Fig. 10 · Parts

Accessories

Part No.Description 24N402CABLE, 6 ft, vent valve, 2 pin for vent valve control 77X529CABLE, power injector system only. Use with 77X528 77X528CABLE, power extension, 15 ft (4.6m), use with 77X529

Technical Data

Vent Valve for Dyna-Star HP USMetric Maximum working pressure*3500 psi24.1 MPa, 241 bar Inlet/Outlet Sizes Outlet (marked “0”)3/8 in. npt(f) Inlet (refill - marked “1”)3/8 in. npt(f) Pressure Relief Valve Factory Set Pressure4000 psi + 250 psi27 MPa, 275 bar + 10% Reset Pressure80% of set pressure Relief Rate**0.1 gallons/minute @3500 psi0.4 liters/minute @24.1 MPa. 241 bar Solenoid Valve Flow**Up to gpm 0.2 gallons/minute, 40 in3/minute0.65 liters/minute Wetted materialsZinc plated steel, carbon steel, aluminum, fluoroelastomer, polyurethane Weight4.0 lbs1.8 kg IP RatingIP65K Solenoid CoilResistance (DC) (Ohms) @ 68°F (20°C)Initial Current Draw (Amps) 24 VDC28.80.83

*Dyna-Star HP Pump Models are rated for 5000 psi (34.47 MPa, 344 bar) maximum working pressure, however, when a vent valve is installed on the HP Pump, the maximum working pressure must be reduced to 3500 psi (24.1 MPa, 241 bar).

**Flow capability depends on viscosity, type of fluid, temperature, etc.

Parts

Page 6 of the Graco LineLazer V 200HS (77X540) user manual — Graco Information
Page 6 · click to enlarge
Page 6

Dimensions

Graco LineLazer V 200HS (77X540) — Dimensions diagram (page 6)
Fig. 11 · Dimensions

4.95 in.

(12.57 cm)

1.5 in (3.81 cm)

2.5 in.

(6.36 cm)

1.5 in.

(3.81 cm)

4.0 in.

(10.16 cm)

Graco Information

For the latest information about Graco products, visit www.graco.com

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

For patent information, see www.graco.com/patents

Original instructions. This manual contains English. MM 332519

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea
  • GRACO INC. AND SUBSIDIARIES
  • P.O. BOX 1441
  • MINNEAPOLIS MN 55440-1441
  • USA

Copyright 2013, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com

August 2014

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Graco LineLazer V 200HS (77X540)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco LineLazer V 200HS (77X540)

Be the first to ask — other owners or our team will answer.

Original document

Graco LineLazer V 200HS (77X540) manual PDF

6 pages·552 KB·Ventilation Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…