Reactor® Reactor® Reactor® 2 Hydraulic Hydraulic Hydraulic
Proportioning Proportioning Proportioning Systems Systems Systems 334945B EN
Hydraulic, Hydraulic, Hydraulic, Heated, Heated, Heated, Plural Plural Plural Component Component Component Proportioner Proportioner Proportioner for for for spraying spraying spraying polyurethane polyurethane polyurethane foam foam foam and and and polyurea polyurea polyurea coatings. coatings. coatings. Not Not Not for for for outdoor outdoor outdoor use. use. use. For For For professional professional professional use use use only. only. only. Not Not Not approved approved approved for for for use use use inin in explosive explosive explosive atmospheres atmospheres atmospheres or or or hazardous hazardous hazardous locations. locations. locations.

For model information, see page 9.
PROVEN QUALITY. LEADING TECHNOLOGY.


The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.


PRESSURIZED PRESSURIZED PRESSURIZED ALUMINUM ALUMINUM ALUMINUM PARTS PARTS PARTS HAZARD HAZARD HAZARD
Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage.
PLASTIC PLASTIC PLASTIC PARTS PARTS PARTS CLEANING CLEANING CLEANING SOLVENT SOLVENT SOLVENT HAZARD HAZARD HAZARD
Many solvents can degrade plastic parts and cause them to fail, which could cause serious injury or property damage.


Isocyanates (ISO) are catalysts used in two component materials.
Spraying or dispensing fluids that contain isocyanates creates potentially harmful mists, vapors, and atomized particulates.


Moisture Moisture Moisture Sensitivity Sensitivity Sensitivity ofof of Isocyanates Isocyanates Isocyanates
Exposure to moisture (such as humidity) will cause ISO to partially cure, forming small, hard, abrasive crystals that become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity.
Some materials may become self-igniting if applied too thick. Read material manufacturer’s warnings and SDS.
Partially cured ISO will reduce performance and the life of all wetted parts.
Keep Keep Keep Components Components Components A and and and B Separate Separate Separate
Cross-contamination can result in cured material in fluid lines which could cause serious injury or damage to equipment. To prevent cross-contamination:
NOTICE NOTICE NOTICE
Changing the material types used in your equipment requires special attention to avoid equipment damage and downtime.
Foam Foam Foam Resins Resins Resins with with with 245 245 245 fafa fa Blowing Blowing Blowing Agents Agents Agents
Some foam blowing agents will froth at temperatures above 90°F (33°C) when not under pressure, especially if agitated. To reduce frothing, minimize preheating in a circulation system.

Reactor Reactor Reactor 2 H-30 30 30 and and and H-30 30 30 Elite Elite Elite
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less.
★ See Approvals, page 15.
6 Packages include gun, heated hose, and whip hose. Elite packages also include Graco InSite and fluid inlet sensors. All Elite hose and gun system packages include Xtreme-Wrap™50 ft (15 m) heated hose. For part numbers, see Accessories, page 15.
= Total system watts used by system, based on maximum heated hose length for each unit.

Models

Reactor Reactor Reactor 2 H-40 40 40 and and and H-40 40 40 Elite Elite Elite
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less.
★ See Approvals, page 15.
6 Packages include gun, heated hose, and whip hose. Elite packages also include Graco InSite and fluid inlet sensors. All Elite hose and gun system packages include Xtreme-Wrap™50 ft (15 m) heated hose. For part numbers, see Accessories, page 15.
= Total system watts used by system, based on maximum heated hose length for each unit.

Models

Reactor Reactor Reactor 2 H-40 40 40 and and and H-40 40 40 Elite Elite Elite (Continued) (Continued) (Continued)
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less.
★ See Approvals, page 15.
6 Packages include gun, heated hose, and whip hose. Elite packages also include Graco InSite and fluid inlet sensors. All Elite hose and gun system packages include Xtreme-Wrap™50 ft (15 m) heated hose. For part numbers, see Accessories, page 15.
= Total system watts used by system, based on maximum heated hose length for each unit.

Models

Reactor Reactor Reactor 2 H-50 50 50 and and and H-50 50 50 Elite Elite Elite
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less.
★ See Approvals, page 15.
6 Packages include gun, heated hose, and whip hose. Elite packages also include Graco InSite and fluid inlet sensors. All Elite hose and gun system packages include Xtreme-Wrap™50 ft (15 m) heated hose. For part numbers, see Accessories, page 15.
= Total system watts used by system, based on maximum heated hose length for each unit.

Models

Reactor Reactor Reactor 2 H-XP2 XP2 XP2 and and and H-XP2 XP2 XP2 Elite Elite Elite
H-XP2 XP2 XP2 Model Model Model H-XP2 XP2 XP2 Elite Elite Elite Model 15 15 15 kW kW kW 15kW 15kW 15kW
Proportioner Proportioner Proportioner ★ 17H062 17H162
Maximum Maximum Maximum Fluid Fluid Fluid Working Working Working Pressure Pressure Pressure psi psi psi (MPa, (MPa, (MPa, bar) bar) bar)
3500 (24.1, 241) 3500 (24.1, 241)
Approximate Approximate Approximate Output Output Output per per per Cycle Cycle Cycle (A+B) (A+B) (A+B) gal. gal. gal. (liter) (liter) (liter)
0.042 (0.16) 0.042 (0.16)
Max Max Max Flow Flow Flow Rate Rate Rate lb/min lb/min lb/min (kg/min) (kg/min) (kg/min) 1.5 (5.7) 1.5 (5.7)
Total Total Total System System System Load Load Load † (Watts) (Watts) (Watts) 23,260 23,260
Configurable Configurable Configurable Voltage Voltage Voltage Phase Phase Phase 230 1Ø 230 3Ø∆ 230 3ØY 230 1Ø 230 3Ø∆ 230 3ØY
Full Full Full Load Load Load Peak Peak Peak Current* Current* Current* 100 59 35 100 59 35
Fusion Fusion Fusion® AP AP AP Package Package Package 6 (Gun Part No.)
AHH162 (246101) Probler Probler Probler P2 P2 P2 Package Package Package 6 (Gun Part No.)
AHH062 (246101)
APH162 (246101)
PHH162 (246101) Heated Heated Heated Hose Hose Hose 50 50 50 ftftft (15 (15 (15 m) m) m)
PHH062 (246101)
P2H162 (GCP2R1)
Heated Heated Heated Whip Whip Whip Hose Hose Hose 10 10 10 ftftft (3 (3 (3 m) m) m)
Graco Graco Graco Insite Insite Insite ✓
Fluid Fluid Fluid Inlet Inlet Inlet Sensors Sensors Sensors (2) (2) (2) ✓
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less.
★ See Approvals, page 15.
6 Packages include gun, heated hose, and whip hose. Elite packages also include Graco InSite and fluid inlet sensors. All Elite hose and gun system packages include Xtreme-Wrap™50 ft (15 m) heated hose. For part numbers, see Accessories, page 15.
= Total system watts used by system, based on maximum heated hose length for each unit.
Voltage Voltage Voltage Configurations Configurations Configurations Key Key Key
Y WYE

Reactor Reactor Reactor 2 H-XP3 XP3 XP3 and and and H-XP3 XP3 XP3 Elite Elite Elite
H-XP3 XP3 XP3 Model Model Model H-XP3 XP3 XP3 Elite Elite Elite Model 20 20 20 kW kW kW 20 20 20 kW kW kW 20 20 20 kW kW kW 20 20 20 kW kW kW
Proportioner Proportioner Proportioner ★ 17H074 17H076 17H174 17H176
Maximum Maximum Maximum Fluid Fluid Fluid Working Working Working Pressure Pressure Pressure psi psi psi (MPa, (MPa, (MPa, bar) bar) bar)
3500 (24.1, 241) 3500 (24.1, 241) 3500 (24.1, 241) 3500 (24.1, 241)
Approximate Approximate Approximate Output Output Output per per per Cycle Cycle Cycle (A+B) (A+B) (A+B) gal. gal. gal. (liter) (liter) (liter)
0.042 (0.16) 0.042 (0.16) 0.042 (0.16) 0.042 (0.16)
Max Max Max Flow Flow Flow Rate Rate Rate lb/min lb/min lb/min (kg/min) (kg/min) (kg/min) 2.8 (10.6) 2.8 (10.6) 2.8 (10.6) 2.8 (10.6)
Total Total Total System System System Load Load Load † (Watts) (Watts) (Watts) 31,700
Configurable Configurable Configurable Voltage Voltage Voltage Phase Phase Phase 230 3Ø∆ 380 3ØY 230 3Ø∆ 380 3ØY
Full Full Full Load Load Load Peak Peak Peak Current* Current* Current* 95 52 95 52
Fusion Fusion Fusion® AP AP AP Package Package Package 6 (Gun Part No.)
APH176 (246102) Probler Probler Probler P2 P2 P2 Package Package Package 6 (Gun Part No.)
APH074 (246102)
APH076 (246102)
APH076 (246102)
APH174 (246102)
APH174 (246102)
APH176 (246102)
P2H176 (GCP2R2) 24K240 24Y240 Heated Heated Heated Hose Hose Hose 50 50 50 ftftft (15 (15 (15 m) m) m) 24K240 (scuff guard) 24Y240 (Xtreme-wrap)
P2H074 (GCP2R2)
P2H076 (GCP2R2)
P2H076 (GCP2R2)
P2H174 (GCP2R2)
P2H174 (GCP2R2)
P2H176 (GCP2R2)
Qty: 1 Qty: 5 Qty: 1 Qty: 5 Qty: 1 Qty: 5 Qty: 1 Qty: 5
Heated Heated Heated Whip Whip Whip Hose Hose Hose 10 10 10 ftftft (3 (3 (3 m) m) m)
246050
Graco Graco Graco Insite Insite Insite ✓ ✓
Fluid Fluid Fluid Inlet Inlet Inlet Sensors Sensors Sensors (2) (2) (2) ✓ ✓
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less.
★ See Approvals, page 15.
6 Packages include gun, heated hose, and whip hose. Elite packages also include Graco InSite and fluid inlet sensors. All Elite hose and gun system packages include Xtreme-Wrap™50 ft (15 m) heated hose. For part numbers, see Accessories, page 15.
= Total system watts used by system, based on maximum heated hose length for each unit.

Voltage Voltage Voltage Configurations Configurations Configurations Key Key Key
Models

Accessories Accessories Accessories
Intertek approvals apply to proportioners without hoses.
Kit Kit Kit Number Number Number Description Description Description
24U315 Air Manifold (4 outlets)
Proportioner Proportioner Proportioner Approvals: Approvals: Approvals:
24T280 Graco InSite Kit
17F837 Inlet Sensor Kit
16X521 Graco InSite Extension cable 24.6 ft (7.5 m)
24N449 50 ft (15 m) CAN cable (for remote display module)
Conforms to ANSI/UL Std. 499 Certified to CAN/CSA Std. C22.2 No. 88
24K207 Fluid Temperature Sensor (FTS) with RTD
24U174 Remote Display Module Kit
15V551 ADM Protective Covers (10 pack)
15M483 Remote Display Module Protective Covers (10 pack)
24M174 Drum Level Sticks
121006 150 ft (45 m) CAN cable (for remote display module)
24N365 RTD Test Cables (to aide resistance measurements)
Approvals · 17G340 Caster Kit · 9902471 9902471 9902471

Related Related Related Manuals Manuals Manuals
The following manuals are shipped with the Reactor 2 . Refer to these manuals for detailed equipment information.
The following manuals are for accessories used with the Reactor 2.
Manuals are also available at www.graco.com
Manual Manual Manual Description Description Description
Manuals are available at www.graco.com
334945 Reactor 2 Hydraulic Proportioning Systems Operation Manual 334005 Reactor 2 Hydraulic Proportioning Systems Shutdown Quick Guide 334006 Reactor 2 Hydraulic Proportioning Systems Startup Quick Guide
System System System Manuals Manuals Manuals
333946 Reactor 2 Repair-Parts
Displacement Displacement Displacement Pump Pump Pump Manual Manual Manual
Feed Feed Feed System System System Manuals Manuals Manuals
309572 Heated Hose, Instructions-Parts
309852 Circulation and Return Tube Kit, Instructions-Parts 309815 Feed Pump Kits, Instructions-Parts
309827 Feed Pump Air Supply Kit, Instructions-Parts Spray Spray Spray Gun Gun Gun Manuals Manuals Manuals
309550 Fusion ™AP Gun 312666 Fusion ™CS Gun 313213 Probler® P2 Gun Accessory Accessory Accessory Manuals Manuals Manuals
3A1905 Feed Pump Shutdown Kit, Instructions-Parts 3A3009 Inlet Sensor Kit, Instructions-Parts 3A1907 Remote Display Module Kit, Instructions-Parts 332735 Air Manifold Kit, Instructions-Parts 3A3010 Caster Kit, Instructions-Parts 333276 Graco InSite ™Kit, Instructions-Parts 3A3084 Elite Kit, Instructions-Part
3A3085 Pumpline Repair, Instructions-Parts
Supplied Manuals · 3A3085 Pump Repair-Parts

Typical Installation, without circulation

* Shown exposed for clarity. Wrap with tape during operation.
J Fluid Supply Lines K Feed Pumps
C Fluid Temperature Sensor (FTS) D Heated Whip Hose
E Fusion Spray Gun F Gun Air Supply Hose
P Gun Fluid Manifold (part of gun)
G Feed Pump Air Supply Lines H Agitator Air Supply Line
S Remote Display Module Kit (optional)

Typical Installation, with system fluid manifold to drum circulation
Typical Typical Typical Installation, Installation, Installation, with with with system system system fluid fluid fluid manifold manifold manifold toto to drum drum drum circulation circulation circulation

* Shown exposed for clarity. Wrap with tape during operation.
J Fluid Supply Lines K Feed Pumps
C Fluid Temperature Sensor (FTS) D Heated Whip Hose
E Fusion Spray Gun F Gun Air Supply Hose
P Gun Fluid Manifold (part of gun) R Recirculation Lines
G Feed Pump Air Supply Lines H Agitator Air Supply Line
S Remote Display Module (optional)

Typical Installation, with gun fluid manifold to drum circulation
Typical Typical Typical Installation, Installation, Installation, with with with gun gun gun fluid fluid fluid manifold manifold manifold toto to drum drum drum circulation circulation circulation

* Shown exposed for clarity. Wrap with tape during operation.
J Fluid Supply Lines K Feed Pumps
C Fluid Temperature Sensor (FTS)
CK Circulation Block (accessory) D Heated Whip Hose
F Gun Air Supply Hose
P Gun Fluid Manifold (part of gun) R Recirculation Lines
G Feed Pump Air Supply Lines H Agitator Air Supply Line
S Remote Display Module (optional)


Component Identification

BA ISO Side Pressure Relief Outlet BB RES Side Pressure Relief Outlet
RR Graco InSite Cellular Module (Elite models only) RS Red Stop Button
CD Advanced Display Module (ADM)
SA ISO Side PRESSURE RELIEF/SPRAY Valve SB RES Side PRESSURE RELIEF/SPRAY Valve TA ISO Side Pressure Transducer (behind gauge GA) TB RES Side Pressure Transducer (behind gauge GB) XA Fluid Inlet Sensor (ISO side, Elite models only) XB Fluid Inlet Sensor (RES side, Elite models only) XF Heated Hose Transformer (behind cover)
EC Electrical Cord Strain Relief EM Electric Motor (behind shroud) FA ISO Side Fluid Manifold Inlet FB RES Side Fluid Manifold Inlet FH Fluid Heater (behind shroud) FM Reactor Fluid Manifold FV Fluid Inlet Valve (RES side shown)
GA ISO Side Pressure Gauge
GB RES Side Pressure Gauge HA ISO Side Hose Connection HB RES Side Hose Connection
FPG Fluid Inlet Valve Pressure Gauge
FTG Fluid Inlet Valve Temperature Gauge
HC Heated Hose Electrical Junction Box
HP Hydraulic Driver (behind shroud) MP Main Power Switch PA ISO Side Pump PB RES Side Pump
HPG Hydraulic Pressure Gauge
Component Identification · Key Key Key · FTS FTS Connection

The ADM display shows graphical and text information related to setup and spray operations.


Key Key Key and and and Indicator Indicator Indicator
Press to stop all proportioner processes. This is not a safety or emergency stop.
Press to select the specific screen or operation shown on the display directly next to each key.
Figure 5 ADM Front View

To prevent damage to the softkey buttons, do not press buttons with sharp objects such as pens, plastic cards, or fingernails.
Use to cancel a data entry field. Also used to return to Home screen.
Press to choose a field to update, to make a selection, to save a selection or value, to enter a screen, or to acknowledge an event.
Component Identification


Figure 6 ADM Back View

CR Token Access Cover CS Backup Battery Access Cover
Table Table Table 2 ADM ADM ADM LED LED LED Status Status Status Descriptions Descriptions Descriptions

LED LED LED Conditions Conditions Conditions Description Description Description
USB USB USB Status Status Status (CL) (CL) (CL)
Green and Yellow Flashing ADM is busy, USB cannot transfer information when in this mode
ADM ADM ADM Status Status Status (CN) (CN) (CN)
Red Steady Flashing Software upload from token in progress
Component Identification

ADM ADM ADM Display Display Display Details Details Details
System System System Errors Errors Errors
The current system error is displayed in the middle of the menu bar. There are four possibilities:
The following screen appears when the ADM is powered up. It remains on while the ADM runs through initialization and establishes communication with other modules in the system.
Icon Icon Icon Function Function Function No Icon No information or no error has occurred

See Troubleshoot Errors, page 60 for more information.
The current system status is displayed at the lower right of the menu bar.
Icons next to the soft keys indicate which mode or action is associated with each soft key. Soft keys that do not have an icon next to them are not active in the current screen.
The menu bar appears at the top of each screen. (The following image is only an example.)

Date Date Date and and and Time Time Time
Navigating Navigating Navigating the the the Screens Screens Screens
The date and time are always displayed in one of the following formats. The time is always displayed as a 24-hour clock.
There are two sets of screens:
on any Run screen to enter the Setup screens. If the system has a password lock, the Password screen displays. If the system is not locked (password is set to 0000), System Screen 1 displays.
The left and right arrows indicate screen navigation.
Screen Screen Screen Menu Menu Menu
The screen menu indicates the currently active screen, which is highlighted. It also indicates the associated screens that are available by scrolling left and right.
on any Setup screen to return to the Home screen.
Press the Enter soft key
to activate the editing function on any screen.
System System System Mode Mode Mode
The current system mode is displayed at the lower left of the menu bar.
Press the Exit soft key
to exit any screen.
Use the other softkeys to select the function adjacent to them.



Advisory. See Troubleshoot Errors, page 60 for more information.
Deviation. See Troubleshoot Errors, page 60 for more information.
Toggle between upper-case, lower-case, and numbers and special characters.
Alarm. See Troubleshoot Errors, page 60 for more information.
Component Identification · Icons Icons Icons · Softkeys Softkeys Softkeys

H-40, H-40, H-40, H-50, H-50, H-50, H-XP3 H-XP3 H-XP3


AAA Temperature Control Module (TCM)
AAB Hydraulic Control Module (HCM)
AAD Wiring Terminal Blocks (H-30/H-XP2 only)
AAF Sacrificial Surge Protector (SSP)
AAJ A Side Heat Breaker
AAK B Side Heat Breaker
AAL Hose Transformer Breaker
AAN TB21 Terminal Block (if equipped)
MP Main Power Switch


HCM HCM HCM Rotary Rotary Rotary Switch Switch Switch (RS) (RS) (RS) Positions Positions Positions
0 = Reactor 2, H-30
1 = Reactor 2, H-40
2 = Reactor 2, H-50
3 = Reactor 2, H-XP2
4 = Reactor 2, H-XP3
Table Table Table 3 HCM HCM HCM Module Module Module LED LED LED (MS) (MS) (MS) Status Status Status Descriptions Descriptions Descriptions

LED LED LED Conditions Conditions Conditions Description Description Description

MS Module Status LEDs see LED Status Table 1 CAN Communication Connections 2 Motor Over-Temperature
8 A Fluid Inlet Sensor 9 B Fluid Inlet Sensor 10 Pump Position Switches
Component Identification

Temperature Temperature Temperature Control Control Control Module Module Module (TCM) (TCM) (TCM) Cable Cable Cable Connections Connections Connections

Table Table Table 4 TCM TCM TCM Module Module Module LED LED LED (7) (7) (7) Status Status Status Descriptions Descriptions Descriptions

LED LED LED Conditions Conditions Conditions Description Description Description
2 Heater Overtemperature 3 CAN Communications Connections 4 Power Out Heater A (ISO) 5 Power Out Heater B (Res) 6 Power Out (Heated Hose) 7 Module Status LEDs 8 Heater A (ISO) Temperature 9 Heater B (RES) Temperature 10 Hose Temperature
Component Identification · 1 Power Input

NOTICE NOTICE NOTICE
Grounding Grounding Grounding
Failure to properly size the equipment may result in damage. To avoid damage to the equipment, follow the guidelines listed below.
The equipment must be grounded to reduce the risk of static sparking and electric shock. Electric or static sparking can cause fumes to ignite or explode. Improper grounding can cause electric shock. Grounding provides an escape wire for the electric current.
Use the following procedure to determine the correct size generator.
Setup

Table Table Table 5 Power Power Power Cord Cord Cord Requirements Requirements Requirements
Model Model Model Input Input Input Power Power Power Cord Cord Cord Specifications* Specifications* Specifications* AWG AWG AWG (mm^2) (mm^2) (mm^2)
H-30, 10.2 kW
200-240 VAC, 1 Phase 4 (21.2), 2 wire + ground
200-240 VAC, 3 Phase, DELTA 8 (8.4), 3 wire + ground
350-415 VAC, 3 Phase, WYE 8 (8.4), 4 wire + ground
H-30, 15.3 kW
200-240 VAC, 1 Phase 4 (21.2), 2 wire + ground
200-240 VAC, 3 Phase, DELTA 6 (13.3), 3 wire + ground
350-415 VAC, 3 Phase, WYE 8 (8.4), 4 wire + ground
H-XP2, 15.3 kW
200-240 VAC, 1 Phase 4 (21.2), 2 wire + ground
200-240 VAC, 3 Phase, DELTA 6 (13.3), 3 wire + ground
350-415 VAC, 3 Phase, WYE 8 (8.4), 4 wire + ground

200-240 VAC, 3 Phase, DELTA 6 (13.3), 3 wire + ground H-40, 15.3 kW
350-415 VAC, 3 Phase, WYE 8 (8.4), 4 wire + ground
200-240 VAC, 3 Phase, DELTA 4 (21.2), 3 wire + ground H-40, 20.4 kW
350-415 VAC, 3 Phase, WYE 6 (13.3), 4 wire + ground
200-240 VAC, 3 Phase, DELTA 4 (21.2), 3 wire + ground H-50, 20.4 kW
350-415 VAC, 3 Phase, WYE 6 (13.3), 4 wire + ground
200-240 VAC, 3 Phase, DELTA 4 (21.2), 3 wire + ground H-XP3, 20.4 kW
350-415 VAC, 3 Phase, WYE 6 (13.3), 4 wire + ground
*Values are for reference only. Refer to amperage listed in Models table (see Models, page 9 ) for given system and compare against latest version of local electrical code to select proper power cord size.
Setup · ti26342a_17D775


Component Component Component A (ISO) (ISO) (ISO) Pump: Pump: Pump: Fill ISO lube reservoir (LR) with Graco Throat Seal Liquid (TSL), part 206995 (supplied).
The Fluid Temperature Sensor (FTS) is supplied. Install FTS between main hose and whip hose (see Related Manuals, page 16).
Install Install Install Heated Heated Heated Hose Hose Hose toto to Proportioner Proportioner Proportioner

Setup

Advanced Display Module (ADM) Operation
Advanced Advanced Advanced Display Display Display Module Module Module (ADM) (ADM) (ADM) Operation Operation Operation
When main power is turned on by turning the main power switch (MP) to the ON position, the power up screen will be displayed until communication and initialization is complete.

Then the power key icon screen will display until the
ADM power on/off button (A)
is pressed for the first time after system power-up.
To begin using the ADM, the machine must be active. To verify the machine is active, verify that the System Status Indicator Light (B) is illuminated green, see Advanced Display Module (ADM), page 22. If the System Status Indicator Light is not green, press
the ADM Power On/Off (A) button
. The System Status Indicator Light will illuminate yellow if the machine is disabled.
Perform the following tasks to fully setup your system.

Advanced Display Module (ADM) Operation
The ADM will start in the Run screens at the Home screen. From the Run screens, press
to access the Setup screens. The system defaults with no password, entered as 0000. Enter the current
to navigate through the Setup Mode screens. See Setup Screens Navigation Diagram, page 45.
. Press
Set a password to allow Setup screen access, see Advanced Screen 1 – General, page 35. Enter any number from 0001 to 9999. To remove the password, enter the current password in the Advanced Screen – General screen and change the password to 0000.

From the Setup screens, press
to return to the Run screens.
password then press

Advanced Display Module (ADM) Operation
Setup Setup Setup Screens Screens Screens Navigation Navigation Navigation


Advanced Display Module (ADM) Operation
Advanced setup screens enable users to set units, adjust values, set formats, and view software information
for each component. Press
to scroll through the Advanced setup screens. Once in the
desired Advanced setup screen, press
to access the fields and make changes. When changes are
to exit edit mode.
Advanced Advanced Advanced Screen Screen Screen 3 — USB USB USB
Use this screen to enable USB downloads/uploads, enable a logs 90% full advisory, enter the maximum number of days to download data, enable specifying date range of data to download, and how frequently USB logs are recorded. See USB Data, page 61.
Advanced Advanced Advanced Screen Screen Screen 1 — General General General
Use this screen to set the language, date format, current date, time, setup screens password (0000 – for none) or (0001 to 9999), and screen saver delay (zero equals screen saver off).


Advanced Advanced Advanced Screen Screen Screen 4 — Software Software Software
Advanced Advanced Advanced Screen Screen Screen 2 — Units Units Units
This screen displays the software part number and software version for the Advanced Display Module, USB Configuration, Hydraulic Control Module, and Temperature Control Module, and Remote Display Module (optional).
Use this screen to set the temperature units, pressure units, volume units, and cycle units (pump cycles or volume).


complete press

Advanced Display Module (ADM) Operation
System System System 3
Use this screen to set the activation pressure for the Pressure Imbalance Alarm and Deviation, enable or disable diagnostic screens, set the maximum and minimum drum volume, and enable drum alarms.
Use this screen to enable alternate pump cylinder sizes, to turn motor standby mode on and off, and to enable recirculation cycle count. Cycles below 700 psi outlet pressure will not be counted unless enabled.


Use this screen to enable Manual Hose Mode and inlet sensors, as well as setting the inlet sensor low pressure alarm and low temperature deviation. Manual Hose Mode disables the hose temperature RTD sensor so the system can operate if the sensors were to malfunction (see Manual Hose Heat Mode, page 51 for more information). Default settings are 10 psi (0.07 MPa, 0.7 bar) for low inlet pressure alarm and 50˚F (10˚C) for low inlet temperature deviation.


Advanced Display Module (ADM) Operation
Add Add Add Recipe Recipe Recipe
Use this screen to add recipes, view saved recipes, and enable or disable saved recipes. Enabled recipes can be selected at the Home Run Screen. 24 recipes can be displayed on the three recipe screens.
recipe field. Press
to enter a recipe name
(maximum 16 characters). Press
to clear the old recipe name.


to highlight the next field and use the
number pad to enter a value. Press
to save.
Enable Enable Enable or or or Disable Disable Disable Recipes Recipes Recipes
to select the recipe that needs to be enabled or disabled.
to highlight the enabled check box.
to enable or disable the recipe.

Advanced Display Module (ADM) Operation
The ADM will start in the Run screens at the “Home” screen. Press
to navigate through the Run Mode screens. See Run Screens Navigation Diagram, page 44.
From the Run screens, press
to access the Setup screens.

Run Screens Navigation Diagram Figure 9

Advanced Display Module (ADM) Operation
Home Home Home — System System System Off Off Off
Home Home Home — System System System With With With Error Error Error
This is the home screen when the system is off. This screen displays actual temperatures, actual pressures at the fluid manifold, and number of cycles.
Active errors are shown in the status bar. The error code, alarm bell, and description of the error will scroll in the status bar.

to acknowledge the error.

Home Home Home — System System System Active Active Active
When the system is active, the home screen displays actual temperature for heat zones, actual pressures at the fluid manifold, the number of cycles, along with all associated control soft keys.
Use this screen to define the setpoints for the A Component Temperature, B Component Temperature, heated hose temperature, and pressure.
Use this screen to turn on heat zones, start the proportioner, stop the proportioner, park the component A pump, and clear cycles.
Maximum Maximum Maximum A and and and B temperature: temperature: temperature: 190°F (88°C)
Maximum Maximum Maximum heated heated heated hose hose hose temperature: temperature: temperature: the lesser of 10°F (5°C) above the highest A or B temperature setpoint or 180°F (82°C).

If the remote display module kit is used, these setpoints can be modified at the gun.

Targets Targets Targets

Advanced Display Module (ADM) Operation
Use this screen to view daily and lifetime cycles or gallons that have been pumped and gallons or liters remaining in the drums.
This screen shows the date, time, event code, and description of all events that have occurred on the system. There are 10 pages, each holding 10 events. The 100 most recent events are shown. See System Events, page 43 for event code descriptions. See Error Codes and Troubleshooting, page 61 for error code descriptions.
The lifetime value is the number of pump cycles or gallons since the first time the ADM was turned on.
The daily value automatically resets at midnight.
The manual value is the counter that can be manually
All events and errors listed on this screen can be downloaded on a USB flash drive. To download logs, see Download Procedure, page 61.
reset. Press
and hold to reset manual counter.


This screen shows daily cycles and gallons that have been sprayed for the day.
This screen shows the date, time, error code, and description of all errors that have occurred on the system.
All information listed on this screen can be downloaded on a USB flash drive. To download logs, see Download Procedure, page 61.
All errors listed on this screen can be downloaded on a USB flash drive. To download logs, see Download Procedure, page 61.



Advanced Display Module (ADM) Operation
This screen displays the last ten errors that occurred on the system. Use the up and down
QR QR QR Codes Codes Codes

arrows to select an error and press
the QR code for the selected error. Press
to access the QR code screen for an error code that is not listed on this screen. See Error Codes and Troubleshooting, page 61, for more information on error codes.

To quickly view online help for a given error code, scan the displayed QR code with your smartphone. Alternately, visit http://help.graco.com and search for the error code to view online help for that code.

Troubleshooting Troubleshooting Troubleshooting · to view

Advanced Display Module (ADM) Operation
Job Job Job Data Data Data
Use this screen to view information for all system components. NOTE: If not visible, this screen may be on the Setup Systems screen (see Setup Mode).
Use this screen to enter a job name or number.


The following information is displayed:
Use this screen to select an enabled recipe. Use the up and down arrows to highlight a recipe and press
to load. The currently loaded recipe is outlined by a green box.
This screen will not display if there are not any enabled recipes. To enable or disable recipes, see Recipes Setup Screen, page 37.

Diagnostic Diagnostic Diagnostic · Recipes Recipes Recipes

Advanced Display Module (ADM) Operation
Use the table below to find a description for all system non-error events. All events are logged in the USB log files.

Event Event Event Code Code Code Description Description Description
EADA Heat On A EADB Heat On B EADH Heat On Hose EAPX Pump On
EAUX USB Drive Inserted EB0X ADM Red Stop Button Pressed
EBDA Heat Off A EBDB Heat Off B EBDH Heat Off Hose EBPX Pump Off

To prevent serious injury, only operate Reactor with all covers and shrouds in place.
Proper system setup, startup, and shutdown procedures are critical to electrical equipment reliability. The following procedures ensure steady voltage. Failure to follow these procedures will cause voltage fluctuations that can damage electrical equipment and void the warranty.
Before daily startup, ensure that the fluid inlet screens are clean. See Flush Inlet Strainer Screen, page 58
The ADM will display the following screen until communication and initialization is complete.
Check level and condition of ISO lube daily. See Pump Lubrication System, page 59.

Running out of fuel will cause voltage fluctuations that can damage electrical equipment and void the warranty. Do not run out of fuel.
Startup

e. Open fluid inlet valves (FV). Check for leaks.



Cross-contamination can result in cured material in fluid lines which could cause serious injury or damage equipment. To prevent cross-contamination:
a. Check that all Setup Setup Setup steps are complete. See Setup, page 29.
b. If an agitator is used, open the agitator’s air inlet valve.
c. If you need to circulate fluid through the system to preheat the drum supply, see Circulation Through Reactor, page 47. If you need to circulate material through the heat hose to the gun manifold, see Circulation Through Gun Manifold, page 48.
d. Turn both PRESSURE RELIEF/SPRAY valves (SA, SB) to SPRAY
f. Hold gun fluid manifold over two grounded waste containers. Open fluid valves A and B until clean, air-free fluid comes from valves. Close valves.


The Fusion AP gun manifold is shown.
Startup

to activate ADM.

Thermal expansion can cause over-pressurization, resulting in equipment rupture and serious injury, including fluid injection. Do not pressurize system when preheating hose.
a. Press
to turn on hose heat zone.
b. If you need to circulate fluid through the system to preheat the drum supply, see Circulation Through Reactor, page 47. If you need to circulate material through the heat hose to the gun manifold, see Circulation Through Gun Manifold, page 48.

c. Wait for the hose to reach set point temperature.
This equipment is used with heated fluid which can cause equipment surfaces to become very hot. To avoid severe burns:

d. Press
to turn on A and B heat zones.
Startup

To prevent equipment damage, do not circulate fluid containing a blowing agent without consulting with your material supplier regarding fluid temperature limits.
to start motor and pumps. Circulate fluid at lowest possible pressure until temperatures reach targets.
To avoid injection injury and splashing, do not install shutoffs downstream of the PRESSURE RELIEF/SPRAY valve outlets (BA, BB). The valves function as overpressure relief valves when set to
to turn on the hose heat zone.
. Lines must be open so valves can automatically relieve pressure when machine is operating.
SB SA
SB) to PRESSURE RELIEF/CIRCULATION
Fluid Circulation · SB) to SPRAY

To prevent equipment damage, do not circulate fluid containing a blowing agent without consulting with your material supplier regarding fluid temperature limits.
Circulating fluid through the gun manifold allows rapid preheating of the hose.
CK
to start motor and pumps. Circulate fluid at lowest possible pressure until temperatures reach targets.
to turn on the hose heat zone.
The Fusion AP gun manifold is shown.
CK CK CK Gun Gun Gun Manual Manual Manual
246362 Fusion AP 309818
256566 Fusion CS 313058
Fluid Circulation

The Fusion AP gun is shown.
to start motor and pumps.
Fusion Fusion Fusion Probler Probler Probler


SB SA
Component A and B outlet pressures will be higher than the hydraulic set pressure, depending on the model. Component A and B (GA, GB) pressure may be viewed on the pressure gauges or the ADM.
Spraying · SB) to SPRAY

until gauges show balanced pressures.
Fusion Fusion Fusion Probler Probler Probler

Flow rate, atomization, and amount of overspray are affected by four variables.
Fusion Fusion Fusion Probler Probler Probler
To prevent material crossover on impingement guns, never never never open fluid manifold valves or trigger gun if pressures are imbalanced.
Spraying

If the system produces the T6DH Sensor Error Hose alarm or the T6DT Sensor Error TCM alarm, use manual hose heat mode until the hose RTD cable or FTS temperature sensor can be repaired.

Do not use Manual Hose Mode for extended periods of time. The system performs best when the hose has a valid RTD signal and can operate in temperature control mode. If a hose RTD breaks, the first priority is to fix the RTD. Manual Hose Mode can help finish a job while waiting for repair parts.


Enable Enable Enable Manual Manual Manual Hose Hose Hose Mode Mode Mode

Hose Hose Hose Current Current Current Settings Settings Settings Hose Hose Hose Current Current Current
Spraying · Default 20A · Maximum 37A

Disable Disable Disable Manual Manual Manual Hose Hose Hose Mode Mode Mode


Spraying

If you stop spraying for a period of time, the unit will enter standby by shutting down the electric motor and hydraulic pump, to reduce equipment wear and minimize heat buildup. The pump icon on the ADM Home screen will flash when in standby.

To restart, spray off target for two seconds. The system will sense the pressure drop and the motor will ramp up to full speed in a few seconds.
To activate or deactivate standby:
on the ADM.
and the arrow keys. Select the desired delay
enter the page for editing.
and the arrow keys. Press enter to select the desired value.
Standby · using · , then

Proper system setup, startup, and shutdown procedures are critical to electrical equipment reliability. The following procedures ensure steady voltage. Failure to follow these procedures will cause voltage fluctuations that can damage electrical equipment and void the warranty.
to stop the pumps.

To prevent electric shock do not remove any shrouds or open the electrical enclosure door while the power is ON.


to park the Component A and Component B pumps. The park operation is complete when green dot goes out. Verify the park operation is complete before moving to next step.

to deactivate the system.
Fusion Fusion Fusion Probler Probler Probler
Shutdown


Follow the Pressure Relief Procedure whenever you see this symbol.

This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing equipment.
. Ensure gauges drop to 0.

The Fusion AP gun is shown.
to stop the pumps.


Pressure Relief Procedure


To flush entire system, circulate through gun fluid manifold (with manifold removed from gun).
To prevent moisture from reacting with isocyanate, always leave the system filled with a moisture-free plasticizer or oil. Do not use water. Never leave the system dry. See Important Two-Component Material Information.
To flush feed hoses, pumps, and heaters separately from heated hoses, set PRESSURE RELIEF/SPRAY valves (SA, SB) to PRESSURE
. Flush through bleed lines (N).

Flushing

Table Table Table 6 Frequency Frequency Frequency ofof of Oil Oil Oil Changes Changes Changes
Ambient Ambient Ambient Temperature Temperature Temperature
Recommended Recommended Recommended Frequency Frequency Frequency
0° to 90° F (-17° to 32° C)
1000 hours or 12 months, whichever comes first
Prior to performing any maintenance procedures, follow Pressure Relief Procedure, page 55.
90° F and above (32° C and above)
500 hours or 6 months, whichever comes first
The operating conditions of your particular system determine how often maintenance is required. Establish a preventive maintenance schedule by recording when and what kind of maintenance is needed, and then determine a regular schedule for checking your system.
Fluid Fluid Fluid Inlet Inlet Inlet Strainer Strainer Strainer Screens Screens Screens
Inspect fluid inlet strainer screens daily, see Flush Inlet Strainer Screen, page 58.
Grease Grease Grease Circulation Circulation Circulation Valves Valves Valves
Grease circulation valves (SA and SB) with Fusion grease (117773) weekly.
ISO ISO ISO Lubricant Lubricant Lubricant Level Level Level
Inspect ISO lubricant level and condition daily. Refill or replace as needed. See Pump Lubrication System, page 59.
To prevent crystallization, do not expose component A to moisture in air.
Gun Gun Gun Mix Mix Mix Chamber Chamber Chamber Ports Ports Ports
Clean gun mix chamber ports regularly. See gun manual.
Maintenance · Moisture Moisture Moisture

Gun Gun Gun Check Check Check Valve Valve Valve Screens Screens Screens
Clean gun check valve screens regularly. See gun manual.
Dust Dust Dust Protection Protection Protection
Use clean, dry, oil-free compressed air to prevent dust buildup on control modules, fans, and motor (under shield).
Vent Vent Vent Holes Holes Holes
Keep vent holes on bottom and back of electrical enclosure and sides and back of transformer enclosure open..
The inlet strainers filter out particles that can plug the pump inlet check valves. Inspect the screens daily as part of the startup routine, and clean as required.
Isocyanate can crystallize from moisture contamination or from freezing. If the chemicals used are clean and proper storage, transfer, and operating procedures are followed, there should be minimal contamination of the A-side screen.
Clean the A-side screen only during daily startup. This minimizes moisture contamination by immediately flushing out any isocyanate residue at the start of dispensing operations.
Maintenance


Check the condition of the ISO pump lubricant daily. Change the lubricant if it becomes a gel, its color darkens, or it becomes diluted with isocyanate.
Gel formation is due to moisture absorption by the pump lubricant. The interval between changes depends on the environment in which the equipment is operating. The pump lubrication system minimizes exposure to moisture, but some contamination is still possible.
Lubricant discoloration is due to continual seepage of small amounts of isocyanate past the pump packings during operation. If the packings are operating properly, lubricant replacement due to discoloration should not be necessary more often than every 3 or 4 weeks.
To change pump lubricant:
Pump Lubrication System Figure 11

To troubleshoot the error:
When an error occurs the error information screen displays the active error code and description.
The error code, alarm bell, and active errors will scroll in the status bar. For a list of the ten most recent errors see Troubleshooting. Error codes are stored in the error log and displayed on the Error and Troubleshooting screens on the ADM.
There are three types of errors that can occur. Errors are indicated on the display as well as by the light tower (optional).
Alarms are indicated by
. This condition indicates a parameter critical to the process has reached a level requiring the system to stop. The alarm needs to be addressed immediately.
to return to the previously displayed screen.
Deviations are indicated by
. This condition indicates a parameter critical to the process has reached a level requiring attention, but not sufficient enough to stop the system at this time.
Advisories are indicated by
. This condition indicates a parameter that is not immediately critical to the process. The advisory needs attention to prevent more serious issues in the future.
To diagnose the active error, see Troubleshoot Errors, page 60.
Errors · Press · or

Error Codes and Troubleshooting
See system repair manual 334946 or visit http://help.graco.com for causes and solutions to each error code, or call your Graco contact listed on the back page of this manual.
USB USB USB Logs Logs Logs
Download Download Download Procedure Procedure Procedure
During operation, the ADM stores system and performance related information to memory in the form of log files. The ADM maintains six log files:
Follow Download Procedure, page 61, to retrieve log files.
Each time a USB flash drive is inserted into the ADM USB port, a new folder named DATAxxxx is created. The number at the end of the folder name increases each time a USB flash drive is inserted and data is downloaded or uploaded.
Event Event Event Log Log Log
The event log file name is 1–EVENT.CSV and is stored in the DATAxxxx folder.
The event log maintains a record of the last 49,000 events and errors. Each event record contains:
Event codes include both error codes (alarms, deviations, and advisories) and record only events.
Actions Taken includes setting and clearing event conditions by the system, and acknowledging error conditions by the user.

Error Codes and Troubleshooting
Job Job Job Log Log Log
The following data is stored in this file:
The job log file name is 2–JOB.CSV and is stored in the DATAxxxx folder.
The job log maintains a record of data points based on the USB Log Frequency defined in the Setup screens. The ADM stores the last 237,000 data points for download. See Setup - Advanced Screen 3 — USB, page 35, for information on setting the Download Depth and USB Log Frequency.
System System System Software Software Software Log Log Log
The system software file name is 4–SYSTEM.CSV and is stored in the DATAxxxx folder.
The system software log lists the following:
Blackbox Blackbox Blackbox Log Log Log File File File
The black box file name is 5–BLACKB.CSV and is stored in the DATAxxxx folder.
The Blackbox log maintains a record of how the system runs and the features that are used. This log will help Graco troubleshoot system errors.
Diagnostics Diagnostics Diagnostics Log Log Log File File File
The diagnostics file name is 6–DIAGNO.CSV and is stored in the DATAxxxx folder.
The Diagnostics log maintains a record of how the system runs and the features that are used. This log will help Graco troubleshoot system errors.
The system configuration settings file name is SETTINGS.TXT and is stored in the DOWNLOAD folder.
Daily Daily Daily Log Log Log
A system configuration settings file automatically downloads each time a USB flash drive is inserted into the ADM. Use this file to back up system settings for future recovery or to easily replicate settings across multiple systems. Refer to the Upload Procedure, page 63 for instructions on how to use this file.
The daily log file name is 3–DAILY.CSV and is stored in the DATAxxxx folder.
The daily log maintains a record of the total cycle and volume sprayed on any day that the system is powered up. The volume units will be the same units that were used in the Job Log.

Error Codes and Troubleshooting
The custom language file name is DISPTEXT.TXT and is stored in the DOWNLOAD folder.
A custom language file automatically downloads each time a USB flash drive is inserted into the ADM. If desired, use this file to create a user-defined set of custom language strings to be displayed within the ADM.
The system is able to display the following Unicode characters. For characters outside of this set, the system will display the Unicode replacement character, which appears as a white question mark inside of a black diamond.
Use this procedure to install a system configuration file and/or a custom language file.
Create Create Create Custom Custom Custom Language Language Language Strings Strings Strings
The custom language file is a tab-delimited text file that contains two columns. The first column consists of a list of strings in the language selected at the time of download. The second column can be used to enter the custom language strings. If a custom language was previously installed, this column contains the custom strings. Otherwise the second column is blank.
Modify the second column of the custom language file as needed and the follow Upload Procedure, page 63 , to install the file.
The format of the custom language file is critical. The following rules must be followed in order for the installation process to succeed.

Use this chart to help identify the proportioner that will work most efficiently with each mix chamber. Flow rates are based on a material viscosity of 60 cps.
Table Table Table 7 Foam Foam Foam Performance Performance Performance Chart Chart Chart
KEY KEY KEY A = H-30 at 50 Hz B = H30 at 60 Hz C = H-40 at 50 Hz D = H-40 at 60 Hz E = H-50 at 50 Hz F = H-50 at 60 Hz
FLOW rate in lb/min (kg/min)

Table Table Table 8 Coatings Coatings Coatings Performance Performance Performance Chart Chart Chart
KEY KEY KEY G = H-XP2 at 50 Hz H = H-XP2 at 60 Hz J = H-XP3 at 50 Hz K = H-XP3 at 60 Hz
FLOW rate in lb/min (kg/min)

Reactor Reactor Reactor 2 Hydraulic Hydraulic Hydraulic Proportioning Proportioning Proportioning System System System
U.S. U.S. U.S. Metric Metric Metric
Maximum Maximum Maximum Fluid Fluid Fluid Working Working Working Pressure Pressure Pressure for for for Bare Bare Bare Proportioners Proportioners Proportioners
Models H-30, H-40, and H-50 2000 psi 13.8 MPa, 138 bar
Models H-XP2 and H-XP3 3500 psi 24.1 MPa, 241 bar
Fluid Fluid Fluid Inlets Inlets Inlets
Component A (ISO) 3/4 npt(f), 250 psi maximum 3/4 npt(f), 1.75 MPa, 17.5 bar maximum
Component B (RES) 3/4 npt(f), 250 psi maximum 3/4 npt(f), 1.75 MPa, 17.5 bar maximum
Fluid Fluid Fluid Outlets Outlets Outlets
Component A (ISO) #8 1/2 in. JIC, with #5 5/16 in. JIC adapter
Component B (RES) #10 5/8 in. JIC, with #6 3/8 in. JIC adapter
Fluid Fluid Fluid Circulation Circulation Circulation Ports Ports Ports
1/4 npsm(m) 250 psi 1.75 MPa, 17.5 bar
Maximum Maximum Maximum Fluid Fluid Fluid Temperature Temperature Temperature
Maximum Maximum Maximum Output Output Output (10 (10 (10 weight weight weight oil oil oil atat at ambient ambient ambient temperature) temperature) temperature)
Model H-30 28 lb/min (60 Hz) 13 kg/min (60 Hz)
Model H-XP2 1.5 gpm (60 Hz) 5.7 liter/min (60 Hz)
Model H-50 52 lb/min (60 Hz) 24 kg/min (60 Hz)
Model H-40 45 lb/min (60 Hz) 20 kg/min (60 Hz)
Model H-XP3 2.8 gpm (60 Hz) 10.6 liter/min (60 Hz)
Output Output Output Per Per Per Cycle Cycle Cycle (A (A (A and and and B) B) B)
Model H-40 0.063 gal. 0.23 liter
Models H-30 and H-50 0.073 gal. 0.28 liter
Models H-XP2 and H-XP3 0.042 gal. 0.16 liter
Technical Specifications


Line Line Line Voltage Voltage Voltage Options Options Options
230V 1 phase and 230V 3 phase units: 195–264 Vac, 50/60 Hz
Amperage Amperage Amperage Requirement Requirement Requirement (phase) (phase) (phase)
Heater Heater Heater Power Power Power (A (A (A and and and B heaters heaters heaters total) total) total)
Hydraulic Hydraulic Hydraulic Reservoir Reservoir Reservoir Capacity Capacity Capacity
Recommended Recommended Recommended Hydraulic Hydraulic Hydraulic Fluid Fluid Fluid
Sound Sound Sound Power, Power, Power, per per per ISO ISO ISO 9614–2 9614–2 9614–2
Sound Sound Sound Pressure Pressure Pressure 1 m From From From Equipment Equipment Equipment
All other brand names or marks are used for identification purposes and are trademarks of their respective owners.
Technical Specifications



Dimensions

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. Graco will, for a period as defined in the table below from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
Part Part Part Description Description Description Warranty Warranty Warranty Period Period Period
24U854 Advanced Display Module 36 Months or 2 Million Cycles (whichever comes first)
24Y263 Hydraulic Control Module 36 Months or 2 Million Cycles (whichever comes first)
24U855 Temperature Control Module 36 Months or 2 Million Cycles (whichever comes first)
All Other Parts 12 Months
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS THIS THIS WARRANTY WARRANTY WARRANTY IS IS IS EXCLUSIVE, EXCLUSIVE, EXCLUSIVE, AND AND AND IS IS IS IN IN IN LIEU LIEU LIEU OF OF OF ANY ANY ANY OTHER OTHER OTHER WARRANTIES, WARRANTIES, WARRANTIES, EXPRESS EXPRESS EXPRESS OR OR OR IMPLIED, IMPLIED, IMPLIED, INCLUDING INCLUDING INCLUDING BUT BUT BUT NOT NOT NOT LIMITED LIMITED LIMITED TO TO TO WARRANTY WARRANTY WARRANTY OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY OR OR OR WARRANTY WARRANTY WARRANTY OF OF OF FITNESS FITNESS FITNESS FOR FOR FOR A PARTICULAR PARTICULAR PARTICULAR PURPOSE PURPOSE PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO GRACO GRACO MAKES MAKES MAKES NO NO NO WARRANTY, WARRANTY, WARRANTY, AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND FITNESS FITNESS FITNESS FOR FOR FOR A PARTICULAR PARTICULAR PARTICULAR PURPOSE, PURPOSE, PURPOSE, IN IN IN CONNECTION CONNECTION CONNECTION WITH WITH WITH ACCESSORIES, ACCESSORIES, ACCESSORIES, EQUIPMENT, EQUIPMENT, EQUIPMENT, MATERIALS MATERIALS MATERIALS OR OR OR COMPONENTS COMPONENTS COMPONENTS SOLD SOLD SOLD BUT BUT BUT NOT NOT NOT MANUFACTURED MANUFACTURED MANUFACTURED BY BY BY GRACO GRACO GRACO.
These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR FOR FOR GRACO GRACO GRACO CANADA CANADA CANADA CUSTOMERS CUSTOMERS CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com For patent information, see www.graco.com/patents To To To place place place an an an order, order, order, contact your Graco Distributor or call to identify the nearest distributor. Phone: Phone: Phone: 612-623-6921 or or or Toll Toll Toll Free: Free: Free: 1-800-328-0211 Fax: Fax: Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.