Hydraulic Variable Ratio, Heated, Plural Component Proportioner. For spraying polyurethane foam and polyurea coatings. For professional use only.
Not for use in explosive atmospheres.
U.S. Patent Pending Russian Patent No. 2359181
See page 2 for model information, including maximum work- ing pressure.


r_256886_313359_1A

Models 2 Supplied Manuals 3 Related Manuals 3 Warnings 4 Isocyanate Conditions 6 Material Self-ignition 6 Keep Components A and B Separate 6 Moisture Sensitivity of Isocyanates 6 Foam Resins with 245 fa Blowing Agents 6 Changing Materials 7 Typical Installation, with circulation 8 Typical Installation, without circulation 9 Component Identification 10
Motor Controls and Indicators 15
Motor ON/OFF Key/LED 15 PARK Key/LED 15 PSI/BAR Keys/LEDs 15 Pressure Key/LED 15 Cycle Count Key/LED 16 Hydraulic Pressure Control Knob 16 Motor Control Arrow Keys 16 Spray Adjustments 16 Setup 17 Startup 22 Spraying 28 Standby 30 Shutdown 30 Pressure Relief Procedure 31 Fluid Circulation 32
Reactor H-VR 10 Pump Assembly 12 Temperature Controls and Indicators 13
Main Power Switch 13 Red Stop Button 13 Actual Temperature Key/LED 13 Target Temperature Key/LED 13 Temperature Scale Keys/LEDs 14 Heater Zone On/Off Keys/LEDs 14 Temperature Arrow Keys 14 Temperature Displays 14 Circuit Breakers 14
Circulation Through Reactor 32 Circulation Through Gun Manifold 33 Diagnostic Codes 34
Temperature Control Diagnostic Codes 34 Motor Control Diagnostic Codes 35 Maintenance 36 Fluid Inlet Strainer Screen 37 Flushing 38 Dimensions 39 Technical Data 40 Performance Charts 41 Graco Standard Warranty 44 Graco Information 44
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less. ◆ Maximum flow rate given for 60 Hz operation. For 50 Hz operation, maximum flow rate is 5/6 of 60 Hz maximum flow.
Models

The following manuals are shipped with the Reactor™ H-VR Proportioner. Refer to these manuals for detailed equipment information.
Order Part 15M334 for a compact disk of Reactor manu- als translated in several languages.
The following manuals are for accessories used with the Reactor™.
Supplied Manuals

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.


Moisture Sensitivity of Isocyanates
Spraying materials containing isocyanates creates potentially harmful mists, vapors, and atomized partic- ulates.
Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity. If used, this partially cured ISO will reduce performance and the life of all wetted parts.
Read material manufacturer’s warnings and material MSDS to know specific hazards and precautions related to isocyanates.
Prevent inhalation of isocyanate mists, vapors, and atomized particulates by providing sufficient ventila- tion in the work area. If sufficient ventilation is not available, a supplied-air respirator is required for everyone in the work area.
The amount of film formation and rate of crystallization varies depending on the blend of ISO, the humidity, and the temperature.
To prevent contact with isocyanates, appropriate per- sonal protective equipment, including chemically impermeable gloves, boots, aprons, and goggles, is also required for everyone in the work area.
To prevent exposing ISO to moisture:
Some materials may become self-igniting if applied too thickly. Read material manufacturer’s warnings and material MSDS.
Cross-contamination can result in cured material in fluid lines which could cause serious injury or damage equipment. To prevent cross-contamination of the equipment’s wetted parts, never interchange compo- nent A (isocyanate) and component B (resin) parts.
Some foam blowing agents will froth at temperatures above 90°F (33°C) when not under pressure, especially if agitated. To reduce frothing, minimize preheating in a circulation system.
Isocyanate Conditions

Changing Materials

Typical Installation, with circulation
Key for FIG. 1
G Feed Pump Air Supply Lines J Fluid Supply Lines K Feed Pumps L Agitator M Desiccant Dryer P Gun Fluid Manifold (part of gun) R Circulation Lines S Fluid Inlet T Hose Manifold
A Reactor H-VR Proportioner B Heated Hose C Fluid Temperature Sensor (FTS) D Heated Whip Hose E Fusion Spray Gun F Gun Air Supply Hose

*Shown exposed for clarity. Wrap with tape during operation.

Typical Installation, without circulation
Key for FIG. 2
H Waste Containers J Fluid Supply Lines K Feed Pumps L Agitator M Desiccant Dryer N Bleed Lines P Gun Fluid Manifold (part of gun) S Fluid Inlet T Hose Manifold
A Reactor H-VR Proportioner B Heated Hose C Fluid Temperature Sensor (FTS) D Heated Whip Hose E Fusion Spray Gun F Gun Air Supply Hose G Feed Pump Air Supply Lines


To prevent damage to soft key buttons, do not press the buttons with sharp objects such as pens, plastic cards, or fingernails.
Key for FIG. 3
BA Component A Pressure Relief Outlet BB Component B Pressure Relief Outlet EC Heated Hose Electrical Connector EM Electric Motor, Fan, and Belt Drive (behind shroud) FA Component A Fluid Manifold Inlet (on left side of manifold block) FB Component B Fluid Manifold Inlet FH Fluid Heater (behind shroud) FM Reactor Fluid Manifold FV Fluid Inlet Valve (B side shown) GA Component A Outlet Pressure Gauge GB Component B Outlet Pressure Gauge HA Component A Hose Connection HB Component B Hose Connection HC Hydraulic Pressure Control HP Hydraulic Pressure Gauge LR ISO Lube Pump Reservoir MC Motor Control Display MP Main Power Switch OP Overpressure Rupture Disk Assembly (on rear of A and B
pumps) RS Red Stop Button SA Component A PRESSURE RELIEF/SPRAY Valve SB Component B PRESSURE RELIEF/SPRAY Valve SC Fluid Temperature Sensor Cable SN Serial Number Plate (one inside cabinet, one on right side
of cabinet) SR Electrical Cord Strain Relief TA Component A Pressure Transducer (behind gauge GA) TB Component B Pressure Transducer (behind gauge GB) TC Temperature Control Display TD Oil Cooler VR Pump Assembly (see page 12)
Component Identification


SN
Detail of Reactor Fluid Manifold
(shroud removed for clarity)
TA
GA GB

Detail of Serial No. Plate

FB
HB
SN
Component Identification · (inside cabinet)

Key for FIG. 4.
AH Guard AJ Clamping Knob AK Lube Fitting AL Ratio Lock Handle AM Ratio Adjustment Wheel AN Frame AP Ratio Adjustment Screw
AA Component A Pump AB Component B Pump AC Hydraulic Proportioner Pump AD Yoke and Rod Guide Assembly AE Pump Drive Link AF Pump Adapter AG Pivot Bracket

AA Detail of Pump Assembly (guard removed for clarity)
Component Identification

Temperature Controls and Indicators

Zone A Arrow Keys
Heater A On/Off Key
Zone B Arrow Keys
Heater B On/Off Key
Hose Zone Arrow Keys
Hose Heater On/Off Key
FIG. 5. Temperature Controls and Indicators
Actual Temperature Key/LED
Located on right side of unit, page 11. Turns Reactor
Press to display actual temperature.
power ON and OFF . Does not turn
heater zones or pumps on.
Press and hold to display electrical current.
Target Temperature Key/LED
Located between temperature control panel and motor
Press to display target temperature.
control panel, page 11. Press to shut off motor
and heater zones only. Use main power switch to shut off all power to unit.
Press and hold to display heater control circuit
board temperature.

Temperature Controls and Indicators
Circuit Breakers
Press or to change temperature scale.
Heater Zone On/Off Keys/LEDs
Located inside Reactor cabinet.
Press to turn heater zones on and off. Also clears
Ref. Size Component
CB1 50 A Hose/Transformer Secondary
heater zone diagnostic codes, see page 34.
CB2 40 A Transformer Primary
CB3 50 A Heater A
LEDs flash when heater zones are on. The duration of each flash shows the extent that the heater is turned on.
CB4 50 A Heater B
CB5 20 A Motor/Pumps

Press , then press or to adjust tem-
perature settings in 1 degree increments.
Show actual temperature or target temperature of heater zones, depending on selected mode. Defaults to actual at startup. Range is 32-190°F (0-88°C) for A and B, 32-180°F (0-82°C) for hose.
CB2
CB5
For wiring and cabling, see repair manual 313540.
ti9884a CB3 CB4

Motor Controls and Indicators

FIG. 6. Motor Controls and Indicators
Pressure Key/LED
Press to turn motor ON and OFF. Also clears
Press to display fluid pressure.
some motor control diagnostic codes, see page 35.
If pressures are imbalanced, display shows higher of two pressures.
Press at end of day to cycle component A pump
to home position, submerging displacement rod. Trigger gun until pump stops. Once parked, motor will automati- cally shut off.
Press or to change pressure scale.

Press to display cycle count.
To clear counter, press and hold for 3 sec.
Use to adjust hydraulic pressure available to the hydrau- lic drive system. Turn knob (HC) clockwise to increase pressure and counterclockwise to decrease pressure. Use hydraulic pressure gauge (HP, page 11) to view hydraulic pressure.
Component A and B outlet pressures will be higher than the hydraulic set pressure, depending on the model. Component A and B pressure may be viewed on the pressure gauges (GA, GB), or the higher of the two pressures may be displayed on the motor control panel (MC). See FIG. 3, page 11.
Use or to:
Flow rate, atomization, and amount of overspray are affected by four variables.
Spray Adjustments · ti7731a ti7732a

NOTICE
Proper system setup, startup, and shutdown pro- cedures are critical to electrical equipment reliabil- ity. The following procedures ensure steady voltage. Failure to follow these procedures will cause voltage fluctuations that can damage electri- cal equipment and void the warranty.
Use the following procedure to determine the cor- rect size generator.
a. Locate Reactor on a level surface. See Dimen- sions, page 39, for clearance and mounting hole dimensions.
a. List system components that use peak load requirements in watts.
b. Do not expose Reactor to rain.
b. Add the wattage required by the system compo- nents.
c. Use the casters to move Reactor to a fixed loca- tion, or bolt to shipping pallet and move with forklift.
d. Select a generator size that is equal to or greater than the determined kVA.
d. To mount on a truck bed or tailer, remove cast- ers and bolt directly to truck or trailer bed. See page 39.
Setup

Power cord is not suppled. See table 2.
Installing this equipment requires access to parts which may cause electric shock or other serious injury if work is not performed properly. Have a qualified electrician connect power and ground to main power switch terminals, see step 3. Be sure your installation complies with all National, State and Local safety and fire codes.
Cord Specification AWG (mm2)
256886 H-VR 4 (21.2), 3 wire + ground
256887 H-VR 8 (8.4), 4 wire + ground
a. 230V, 3 phase: Using 5/32 or 4 mm hex allen wrench, connect three power leads to L1, L2, and L3. Connect green to ground (GND).
Full Load Peak Amps*

256886 H-VR 230V (3) 71 26,600
256887 H-VR 400V (3) 41 26,600
* Full load amps with all devices operating at maxi- mum capabilities. Fuse requirements at various flow rates, ratios, and mix chamber sizes may be less.
** Total system watts, based on maximum hose length for each unit, 410 ft (125 m) including whip hose.
b. 400V, 3 phase: Using 5/32 or 4 mm hex allen wrench, connect three power leads to L1, L2, and L3. Connect neutral to N. Connect green to ground (GND).

The motor must rotate counter-clockwise when viewed from shaft end. To reverse rotation, disconnect power and reverse power leads L1 and L2.

to component A and B drums. See FIG. 1, page 8.
a. Install feed pumps (K) in component A and B supply drums. See FIG. 1 and FIG. 2, pages 8 and 9.

b. Seal component A drum and use desiccant dryer (M) in vent.
c. Install agitator (L) in component B drum, if nec- essary.
d. Ensure A and B inlet valves (FV) are closed.

b. Alternatively: Secure supplied bleed tubes (N) in grounded, sealed waste containers (H). See FIG. 2, page 9.
The Fluid Temperature Sensor (FTS) is supplied. Install FTS between main hose and whip hose. See Heated Hose manual 309572 for instructions.
Supply hoses from feed pumps should be 3/4 in. (19 mm) ID.
e. Connect and tighten component A and B supply hose to the 3/4 npt(f) swivel on the component A and B inlet valve.
Do not install shutoffs downstream of the PRESSURE RELIEF/SPRAY valve outlets (BA, BB). The valves function as overpressure relief valves when set to
SPRAY . Lines must be open so valves can automatically relieve pressure when machine is oper- ating. If circulating fluid back to the supply drums, use high pressure hose rated to withstand the maximum work- ing pressure of this equipment.
a. Recommended: Connect high pressure hose (R) to relief fittings (BA, BB) of both PRES- SURE RELIEF/SPRAY valves, Route hose back
Setup · ti9880a BA

bends. Wrap cable and electrical connections with electrical tape.
See Heated Hose manual 309572 for detailed instruc- tions on connecting heated hoses.

If spraying at a ratio other than 1:1, an E24 may occur. Size hoses and mix chamber appropriately to avoid pressure imbalance.
a. Turn main power OFF .

b. Assemble heated hose sections, FTS, and whip hose.
c. Connect A and B hoses to A and B outlets on Reactor fluid manifold (FM). Hoses are color coded: red for component A (ISO), blue for com- ponent B (RES). Fittings are sized to prevent connection errors.
Do not connect manifold to gun.


A
P
11. Pressure check hose
B
See hose manual. Pressure check for leaks. If no leaks, wrap hose and electrical connections to protect from damage.
Manifold hose adapters (N, P) allow use of 1/4 in. and 3/8 in. ID fluid hoses. To use 1/2 in. (13 mm) ID fluid hoses, remove adapters from fluid manifold and install as needed to connect whip hose.
d. Connect cables (Y). Connect electrical connec- tors (V). Be sure cables have slack when hose
Setup

a. Reactor: is grounded through power cord. See page 18.
b. Spray gun: connect whip hose ground wire to FTS, page 19. Do not disconnect wire or spray without whip hose.
c. Fluid supply containers: follow your local code.
d. Object being sprayed: follow your local code.
e. Solvent pails used when flushing: follow your local code. Use only metal pails, which are con- ductive, placed on a grounded surface. Do not place pail on a nonconductive surface, such as paper or cardboard, which interrupts grounding continuity
f. To maintain grounding continuity when flushing or relieving pressure, hold a metal part of spray gun firmly to the side of a grounded metal pail, then trigger gun.
a. Hydraulic reservoir is filled at the factory. Check fluid level before operating the first time, and weekly thereafter. See Maintenance, page 36.
Setup

See table 3 for ratios with the one pump set at 1.0 and available settings for the second pump.

Do not operate Reactor without all covers and shrouds in place. Do not attempt to change ratio while machine is pressurized or running. Do not loosen ratio lock handle if A and B component pumps are pressurized or while the pumps are operating.

The stroke lengths of the fluid pumps (AA and AB) can be adjusted to select the ratio. The frame (AN) has three pin positions for the bottom of the pump and a slider mechanism at the top of the pump, which allows for positioning of the pump at any required position. This allows for a a range of ratio settings between the first and last settings on the pump drive link.
a. Shutdown system, see page 30.
b. Relieve pressure, see page 31.
c. Loosen four clamping knobs (AJ) and remove guard (AH).



d. Use label on the pump drive link (AE) to identify the correct position of the pump that needs to be adjusted. See FIG. 8.
Startup

e. Remove base pin (BP) from frame (AN) if the base of the pump needs to be moved. See FIG. 8.


f. Loosen ratio lock handle (AL) over the pump that needs adjustment. Use a soft mallet to loosen ratio lock handle if necessary. Turn ratio adjustment wheel (AM) until the mark on the pump adapter block (AF) lines up with the cor- rect position on the ratio indicator label on the pump drive link (AE).
h. Ensure top of pump is in correct ratio position. Tighten ratio lock handle (AL).
i. Install guard (AH) and tighten clamping knobs (AJ). See FIG. 7.
g. Reinstall base pin (BP) if it was removed. Ensure bottom of pump is in correct position. See FIG. 8.
For highest volume of material: Ensure pump has lon- gest stroke length. Set the pump with more flow closest to hydraulic pump (AC) or at 1.0 to achieve maximum flowrates. See FIG. 8.
Startup

Open fluid valves A and B until clean, air-free fluid comes from valves. Close valves.
The Reactor is tested with oil at the factory. Flush out the oil with a compatible solvent before spraying. See page 38.

a. Check that all Setup steps are complete.
b. Turn on component B agitator, if used.
c. Turn both PRESSURE RELIEF/SPRAY valves
(SA, SB) to SPRAY .

d. Start feed pumps.
e. Open fluid inlet valves (FV). Check for leaks.

Do not mix components A and B during startup. Always provide two grounded waste containers to keep component A and component B fluids separate.
f. Use feed pumps to load system. Hold gun fluid manifold over two grounded waste containers.
Startup

B

desired temperature. Repeat for and
zones.
For zone only, if FTS is disconnected at startup,
display will show hose current (0A). See step j, page 26.
e. Press to display actual temperatures.

Do not turn on hose heat without fluid in hoses.
Temperature Controls and Indicators, see page 13

f. Turn on heat zone by pressing .
Preheat hose (15-60 min). Indicator will flash very slowly when fluid reaches target tempera- ture. Display shows actual fluid temperature in hose near FTS.

Thermal expansion can cause overpressurization, resulting in equipment rupture and serious injury, including fluid injection. Do not pressurize system when preheating hose.
a. Turn main power ON .
g. Turn on and heat zones by press-
b. Press or to change temperature
scale.
ing for each zone.
c. Press .
h. Hold to view electrical currents for each
zone.
d. To set heat zone target temperature,
i. Hold to view heater control circuit board
press or until display shows
temperature.
Startup

j. Manual current control mode only:


When in manual current control mode, monitor hose temperature with thermometer. Install per instructions below. Thermometer reading must not exceed 160°F (71°C). Never leave machine unattended when in manual current control mode.
If FTS is disconnected or display shows diag- nostic code E04, turn main power switch OFF
then ON to clear diagnostic
code and enter manual current control mode.
display will show current to hose. Current
is not limited by target temperature.
Motor Controls and Indicators, see page 15
To prevent overheating, install hose thermome- ter close to gun end, within operator view. Insert thermometer through foam cover of A compo- nent hose so stem is next to inner tube. Ther- mometer reading will be about 20°F less than actual fluid temperature.
a. Press to display the pressure reading.
b. Press motor . Motor and pumps start.
If thermometer reading exceeds 160°F (71°C),
Display shows system pressure.
reduce current with key.
Motor must rotate counterclockwise when viewed from shaft end. See Connect electrical cord, page 18.
c. Adjust hydraulic pressure control until display shows desired fluid pressure.
If display pressure is greater than desired pressure, reduce the hydraulic pressure and trigger gun to reduce pressure.
Startup · ti7731a ti7732a

Check the pressure of each proportioning pump using the component A and B gauges. The pressures should be approximately equal and must remain fixed.
100 7 600 42 200 14 700 49 300 21 800 56 400 28 900 63 *500 *35 999 69
d. To display cycle count, press .
* Factory default setting.
To clear counter, press and hold for 3 sec.
d. Turn main power switch OFF to save
e. Press or to change pressure
changes. PSI BAR
scale.
The pressure imbalance function (status code 24, page 35) detects conditions that can cause off-ratio spray, such as loss of feed pressure/supply, pump seal failure, clogged fluid inlet filter, or a fluid leak.
Code 24 (pressure imbalance) is set to an alarm as the default. To change to a warning, see H-VR Repair-Parts manual 313540.
The pressure imbalance default is factory-set at 500 psi (3.5 MPa, 35 bar). For tighter ratio error detection, select a lower value. For looser detection or to avoid nuisance alarms, select a higher value.
a. Turn main power switch OFF .
b. Press and hold or , then turn main
power switch ON . Display will read
dP500 for psi or dP_35 for bar.
c. Press or to select desired pres-
sure differential (100-999 in increments of 100 psi, or 7-70 in increments of 7 bar). See TABLE 4.
Startup

SPRAY .


, until gauges show balanced pressures.

In this example, B side pressure is higher, so use the B side valve to balance pressures.

Spraying


On impingement guns, never open fluid manifold valves or trigger gun if pressures are imbalanced.

If you stop spraying for a period of time, the unit will enter standby (if enabled). See page 30.
Spraying

Shutdown
If you stop spraying for a period of time, the unit will enter standby by shutting down the electric motor and hydraulic pump, to reduce equipment wear and mini- mize heat buildup. The ON/OFF LED and the pres- sure/cycle display on the motor control panel will flash when in standby.
a. Press .
b. Trigger gun until pump A stops in the retracted position and the pressure of both pumps bleeds down.
The , , and heat zones will not be
shut off in standby.
To restart, spray off target for 2 sec. The system will sense the pressure drop and the motor will ramp up to full speed in a few seconds.
This feature is disabled from the factory.
To activate or disable standby, adjust DIP switch #3 on the motor control board. See Reactor Repair-Parts man- ual 313540.
The idle time before entering standby is user-settable as follows:
ON .
ting (5-20, in 5 minute increments). This sets the length of inactive time before the unit will enter standby.
changes.
Standby · ti10971a FV



to PRESSURE RELIEF/CIRCULATION . Route fluid to waste containers or supply tanks. Ensure gauges drop to 0.

SB
Pressure Relief Procedure

Circulation Through Reactor

and heat zones by pressing .
Do not turn on heat zone unless hoses are
Do not circulate fluid containing a blowing agent with- out consulting with your material supplier regarding fluid temperature limits.
already loaded with fluid.
To circulate through gun manifold and preheat hose, see page 33.
the minimum required to circulate fluid until

and temperatures reach targets.
Do not install shutoffs downstream of the PRESSURE RELIEF/SPRAY valve outlets (BA, BB). The valves function as overpressure relief valves when set to
SPRAY . Lines must be open so valves can automatically relieve pressure when machine is oper- ating.
culate fluid at lowest possible pressure until temper- atures reach targets.


SA
SB
SB
Fluid Circulation

the minimum required to circulate fluid until
and temperatures reach targets.
Do not circulate fluid containing a blowing agent with- out consulting with your material supplier regarding fluid temperature limits.
Circulating fluid through the gun manifold allows rapid preheating of hose.
culate fluid at lowest possible pressure until temper- atures reach targets.

R CK
, , and heat zones by pressing
Fluid Circulation

Temperature Control Diagnostic Codes
Temperature control diagnostic codes appear on tem- perature display.
These alarms turn off heat. E99 clears automatically when communication is regained. Codes E03 through
E06 can be cleared by pressing . For other codes,
turn main power OFF then ON to clear.
See repair manual for corrective action.
Code Code Name Alarm Zone
01 High fluid temperature Individual
02 High current Individual
03 No current Individual
04 FTS not connected Individual
05 Board overtemperature Individual
06 Loss of zone communication Individual
30 Momentary loss of communica- tion
99 Loss of display communication All
For hose zone only, if FTS is disconnected at startup, display will show hose current 0A.
Diagnostic Codes · All

Motor control diagnostic codes E21 through E27 appear on pressure display.
Reactor will continue to run. Press to clear. A
There are two types of motor control codes: alarms and warnings. Alarms take priority over warnings.
See repair manual for corrective action.
is turned OFF then ON .
Alarms turn off Reactor. Turn main power OFF
No. Code Name Alarm or
21 No transducer (component A) Alarm
then ON to clear.
22 No transducer (component B) Alarm
23 High pressure Alarm
24 Pressure imbalance Selectable; see repair manual
Alarms can also be cleared, except for code 23, by
pressing .
27 High motor temperature Alarm
30 Momentary loss of communi- cation
Code 24 (pressure imbalance) is set to an alarm default of 500 psi (3.5 MPa, 35 bar). To change to a warning, see Reactor Repair-Parts manual 313540. To change the default pressure imbalance setting, see page 27.
31 Pumpline switch failure/high cycle rate
99 Loss of communication Alarm




S
IM
0 to 90°F (-17 to 32°C)
1000 hours or 12 months, whichever comes first
90°F and above (32°C and above)
500 hours or 6 months, whichever comes first
Maintenance · Ambient Temperature · Recommended Frequency

Fluid Inlet Strainer Screen
The inlet strainers filter out particles that can plug the pump inlet check valves. Inspect the screens daily as part of the startup routine, and clean as required.
Use clean chemicals and follow proper storage, transfer, and operating procedures, to minimize contamination of the A-side screen.

Clean the A-side screen only during daily startup. This minimizes moisture contamination by immediately flush- ing out any isocyanate residue at the start of dispensing operations.
* See Reactor Repair-Parts manual 313540 for fluid filter screen replacements.

Flush equipment only in a well-ventilated area. Do not spray flammable fluids. Do not turn on heaters while flushing with flammable solvents.
RELIEF/CIRCULATION . Flush through bleed lines (N).

N
N
Flushing

Dimension in. (mm) A (height) 57.31 (1455.42) B (width) 37.86 (961.6) C (depth) 33 (838.2)
D (front and rear mounting holes) 32.5 (825.5) F (side mounting holes) 30.375 (7715) G (mounting post inner diameter) 0.44 (11)

Dimensions

Category Data Maximum Fluid Working Pressure 3500 psi (24.1 MPa, 241 bar) Fluid Inlets 3/4 npsm union in 1 in. npt(f) ball valve Fluid Outlets Component A (ISO): #8 (1/2 in.) JIC, with #5 (5/16 in.) JIC adapter Component B (RES): #10 (5/8 in.) JIC, with #6 (3/8 in.) JIC adapter Fluid Circulation Ports 1/4 npsm(m), with plastic tubing, 250 psi (1.75 MPa, 17.5 bar) maximum Maximum Fluid Temperature 190°F (88°C) Maximum Output (10 weight oil at ambient temperature) 1:1
Output per Cycle Variable: 2 oz.- 5 oz. (60 cc - 150 cc) per pump* Stroke Length Variable: 2 in. - 5 in. (5.08 cm - 12.7 cm) Line Voltage Requirement 230V 3 phase units: 195-264 Vac, 50/60 Hz 400V 3 phase units: 338-457 Vac, 50/60 Hz Amperage Requirement See Models, page 2. Heater Power (A and B heaters total, no hose)
See Models, page 2.
Hydraulic reservoir capacity 3.5 gal. (13.6 liters) Recommended hydraulic fluid Citgo A/W Hydraulic Oil, ISO Grade 46 Sound power, per ISO 9614-2 90.9 dB(A) Sound pressure, 1 m from equipment 84.0 dB(A)
Weight 955 lb (433 kg) Wetted Parts Aluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome, fluoroelastomer, PTFE, ultra-high molecular weight polyethylene, chemically resistant o-rings
*Output example: 2.5:1 ratio = 150 cc (B side):60 cc (A side) 2.5:1 output = 150 cc (B side) + 60 cc (A side) = 210 cc per cycle
All other brand names or marks are used for identification purposes and are trademarks of their respective owners.
Technical Data

2000 (13.8, 138)
KEY A = H-25 at 50 Hz B = H-25 at 60 Hz C = H-40 at 50 Hz D = H-40 at 60 Hz E = H-50 at 50 Hz ❄F = H-50 at 60 Hz G = H-VR at 60 Hz
Pressure in psi (MPa, bar)
1500 (10.3, 103)
G
1000 (6.9, 69)
500 (3.4, 34)
0 5 (2.3)
25 (11.4) 15 (6.8)
35 (15.9)
45 (20.5)
55 (25.0)
Flow Rate in lb/min (kg/min)
❄ Pressure flow curve for model 253725 (H-50 230V 1 phase) not shown. Maximum pressure limited to 1700 psi (11.7 MPa, 11.7 bar)
3500 (24.1, 241)
KEY H = H-XP2 at 50 Hz J = H-XP2 at 60 Hz K = H-XP3 at 50 Hz L = H-XP3 at 60 Hz M = H-VR at 60 Hz
3000 (20.7, 207)
Pressure in psi (MPa, bar)
2500 (17.2, 172)
J
2000 (13.8, 138)
M
1500 (10.3, 103)
1000 (6.9, 69)
500 (3.4, 34)
0 0.5 1.0 1.5 2.0 2.5 3.0 (1.9) (3.8) (5.7) (7.6) (9.5) (11.4)
Flow Rate in gal/min (liter/min)
Performance Charts

140 (78) 130 (72) 120 (67) 110 (61) 100 (56)
KEY H-VR = 15.3 kW
Delta T in degrees F (degrees C)
0 0.5 (1.9)
2.0 (7.6) 1.0 (3.8)
2.5 (9.5) 1.5 (5.7)
4.0 (15.1) 3.0 (11.4)
3.5 (13.2)
4.5 (17.0)
Flow Rate in gpm (lpm)
★Heater performance data is based on testing with 10 wt.
hydraulic oil and 230V across heater power wires.

Performance Charts

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 313539