Merkur ® Pump Assembly 312794E
For high-performance finishing and coating applications in hazardous or non-hazardous locations. For professional use only.

See page 4 for model information, including maximum work- ing pressure.
ll 2 G


Pump Part Number Matrix
Check your pump’s identification plate (ID) for the 6-digit part number. Use the following matrix to define the construction of your pump, based on the six digits. For example, Part No. W 1 5 A A S represents a wet cup pump (W), 15 to 1 ratio (15), 25 cc lower (A), 3 UHMWPE/2 PTFE pack- ings with chromex rod coating, no data monitoring, low noise exhaust (A), and stainless steel construction (S).

* Cycle refers to combination of one upstroke and one downstroke.

Pump Models

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

Related Manuals


K
J
H
D
B
M
E G
F
FIG. 1. Component Identification
Key: A Ground Wire B TSL Reservoir C Wet Cup (not visible, under TSL reservoir) D Fluid Outlet E Fluid Inlet F Lower Cylinder G Upper Cylinder H Tie Rod Shield J Displacement Pump Adapter K Tie Rod L Coupling Nut M Jam Nut N Air Motor
Component Identification

General Information
Pump: See FIG. 2. Verify that the ground screw (GS) is attached and tightened securely to the air motor. Con- nect the other end of the ground wire (U) to a true earth ground.
Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing.

Always use Genuine Graco Parts and Accessories, available from your Graco distributor. If you supply your own accessories, be sure they are adequately sized and pressure-rated for your system.
Prepare the Operator
FIG. 2. Ground screw and wire
All persons who operate the equipment must be trained in the operation of all system components as well as the proper handling of all fluids. All operators must thor- oughly read all instruction manuals, tags, and labels before operating the equipment.
Air and fluid hoses: Static electricity may build up when fluids flow through pumps, hoses, and sprayers. At least one hose must be electrically conductive, with a maximum of 500 ft. (150 m) combined hose length to ensure grounding continuity. Check electrical resistance of hose. If total resistance to ground exceeds 25 meg- ohms, replace hose immediately.
Ensure that you have an adequate compressed air supply.
Air compressor: follow manufacturer’s recommenda- tions.
Bring a compressed air supply line from the air com- pressor to the pump location. Be sure all air hoses are properly sized and pressure-rated for your system. Use only electrically conductive hoses.
Spray gun / Dispense valve: Ground the spray gun through connection to a Graco-approved grounded fluid hose.
Fluid supply container: follow local code.
Keep the site clear of any obstacles or debris that could interfere with the operator's movement.
Object being sprayed: follow local code.
Have a grounded, metal pail available for use when flushing the system.
Solvent pails used when flushing: follow local code. Use only conductive metal pails, placed on a grounded surface. Do not place the pail on a nonconductive sur- face, such as paper or cardboard, which interrupts grounding continuity.
To maintain grounding continuity when flushing or relieving pressure: hold metal part of the spray gun/dispense valve firmly to the side of a grounded metal pail, then trigger the gun/valve.
The equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit.
Installation

Mount the pump only to Graco wall bracket 15T795, or to a Graco cart, available from your distributor. Pump dimensions are shown on page 28. For wall mounted pumps, follow these guidelines:
Be sure all air hoses (N) and fluid hoses (M) are prop- erly sized and pressure rated for your system. See FIG. 3. Use only electrically conductive fluid hoses.
Install the following accessories in the order shown in FIG. 3, using adapters as necessary.
Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing or moving parts.
Be sure the valve is easily accessible from the pump and located downstream from the air regulator.
Installation

A Air Shutoff Valve B Air Filter (optional accessory) C Gun Air Pressure Gauge D Gun Air Pressure Regulator E Bleed Type Master Air Valve F DataTrak G Pump Air Pressure Gauge H Pump Air Pressure Regulator J Solenoid Release Button (not visible) K Gun Swivel
L Air-Assisted Spray Gun M Gun Fluid Supply Hose N Gun Air Supply Hose P Fluid Filter R Pump Fluid Outlet S Grounding Wire T Wet-Cup (not visible, see FIG. 4, page 11) U Pump Fluid Inlet V Suction Hose W Fluid Drain Valve

M
FIG. 3. Typical Installation. (Graco Cart-Mounted Package Shown.)
Installation

Pressure Relief Procedure
Trigger Lock
Always engage the trigger lock when you stop spraying to prevent the gun from being triggered accidentally by hand or if dropped or bumped.
Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing or moving parts.
Before starting, fill wet cup (T) 1/3 full with Graco Throat Seal Liquid (TSL) or compatible solvent.

FIG. 4. Fill Wet Cup
The equipment was tested with lightweight oil, which is left in the fluid passages to protect parts. To avoid con- taminating your fluid with oil, flush the equipment with a compatible solvent before using the equipment. See Maintenance, page 13.
Operation

Never allow the pump to run dry of the fluid being pumped. A dry pump quickly accelerates to a high speed, possibly damaging itself. If your pump accel- erates quickly, or is running too fast, stop it immedi- ately and check the fluid supply. If the supply container is empty and air has been pumped into the lines, refill the container and prime the pump and the lines with fluid, or flush and leave it filled with a compatible solvent. Be sure to eliminate all air from the fluid system.

For a brief shutdown, relieve the pressure, page 11. Stop the pump at the bottom of its stroke to prevent fluid from drying on the exposed displacement rod and dam- aging the throat packings.
For a longer shutdown, or overnight, always flush the pump before the fluid dries on the displacement rod. Relieve the pressure, page 11.
Operation · E H ti11882a

The operating conditions of your particular system determine how often maintenance is required. Establish a preventive maintenance schedule by recording when and what kind of maintenance is needed, and then determine a regular schedule for checking your system.
Before each use, check all hoses for wear or damage. Replace as necessary. Check that all threaded connec- tions are tight and leak-free.
Read all Warnings. Follow all Grounding instructions. See page 8.
Fill the wet cup one-half full with Graco Throat Seal Liq- uid (TSL). Maintain level daily.
Flush the pump:
Flush at the lowest pressure possible. Flush with a fluid that is compatible with the fluid you are pumping and with the wetted parts in your system. Check with your fluid manufacturer or supplier for recommended flushing fluids and flushing frequency.
Maintenance

Relieve the pressure before checking or servicing the equipment.
Pump output low on both strokes. Restricted air supply lines. Clear any obstructions; be sure all shutoff valves are open; increase pressure, but do not exceed maximum working pressure.
Exhausted fluid supply. Refill and reprime pump.
Clogged fluid outlet line, valves, etc. Clear.
Worn piston packing. Replace. See displacement pump manual 312792.
Pump output low on only one stroke. Held open or worn ball check valves. Check and repair.
Worn piston packings. Replace.
No output. Improperly installed ball check valves. Check and repair.
Pump operates erratically. Exhausted fluid supply. Refill and reprime pump.
Held open or worn ball check valves. Check and repair.
Worn piston packing. Replace.
Pump will not operate. Restricted air supply lines. Clear any obstructions; be sure all shut off valves are open; increase pressure, but do not exceed maximum working pressure.
Exhausted fluid supply. Refill and reprime pump.
Clogged fluid outlet line, valves, etc. Clear.
Damaged air motor. See air motor manual 312796.
Fluid dried on piston rod. Disassemble and clean pump. See page 15 and manual 312792. In future, stop pump at bottom of stroke.
Runaway solenoid has tripped. Retract solenoid. See air motor manual 312796.
Troubleshooting · Problem Cause Solution





Threads are very sharp. Use a rag to protect hands when hand turning or carrying the pump.
Repair · ti12812a ti12813a

LW025A 23-26 ft-lb (31-35 N•m)

LW050A–LW150A 75-80 ft-lb (102-108 N•m)

be flush with plate.
FIG. 6. Align cylinder and adapter plate.

See manual 312796 for air motor service and parts information,
M02xxx 5-10 ft-lb (7-13.5 N•m)
All Other Sizes 50-55 ft-lb (68-75 N•m)
Cart Mount: Remove the two screws on the arms and tip back or remove the air control panel for eas- ier removal of the air motor.

M02xxx 15-20 ft-lb (20-27 N•m)
All Other Sizes 50-60 ft-lb (68-81 N•m)
M02xxx 23-26 ft-lb (31-35 N•m)
All Other Sizes 75-80 ft-lb (102-108 N•m)



Torque to 70-75 ft-lb (95-102 N•m) 4

Ref. Part No. Description
Ref. Part No. Description
1 See Table MOTOR 1 2 See Table DISPLACEMENT PUMP 1 3* See Table ADAPTER, pump 1 4 See Table NUT, jam 1 5* 15M661 15M662
10* COLLAR, coupling; see page
20 to order package of 10 2
11* See Table SHIELD, tie rod 1 12* See Table SHIELD, drip 1 13* 238909 WIRE, grounding assembly, not shown
M02xxx motor All other motor sizes
Not sold separately.
3 3 7* See Table RESERVOIR, TSL 1 8* See Table ADAPTER, 1/2-20 ID X M22 x
M02xxx motor All other motor sizes
* Included in Connecting Kit. See page 20 to order the correct kit for your pump.
cards are available at no cost.
LW025x displacement pumps All other pump sizes
Parts That Vary by Model
Motor Piston Diam. (in.)
(12) W10CAS M04LN0 3.5 LW075A 15R978 24A636 24A623 15M675 24A958 15T462 W10CBS M04LT0 W15AAS M02LN0 2.5 LW025A 15R862 24A634 24A620 24A957 15T461 W15AES W15BAS M04LN0 3.5 LW050A 15R977 24A635 24A622 15M675 24A958 15T462 W15BBS M04LT0 W15FAS M12LN0 6.0 LW150A 15T395 24A639 24A628 24A959 15V028 W15FBS M12LT0 W18EAS M12LN0 6.0 LW125A 15T394 24A638 24A627 24A959 15V028 W18EBS M12LT0 W23DAS M12LN0 6.0 LW100A 15T393 24A637 24A626 24A959 15V028 W23DBS M12LT0 W24FAS M18LN0 7.5 LW150A 15T395 24A639 24A628 24A959 15V028 W24FBS M18LT0 W28EAS M18LN0 7.5 LW125A 15T394 24A638 24A627 24A959 15V028 W28EBS M18LT0 W30AAS M04LN0 3.5 LW025A 15R863 24A634 24A621 24A958 15T462 W30ABS M04LT0 W30CAS M12LN0 6.0 LW075A 15T392 24A636 24A625 24A959 15V028 W30CBS M12LT0 W36DAS M18LN0 7.5 LW100A 15T393 24A637 24A626 24A959 15V028 W36DBS M18LT0 W45BAS M12LN0 6.0 LW050A 15T391 24A635 24A624 24A959 15V028 W45BBS M12LT0 W48CAS M18LN0 7.5 LW075A 15T392 24A636 24A625 24A959 15V028 W48CBS M18LT0

LW100A LW125A LW150A 2.5 in. motor
3.5 in. motor
3.5 in. motor
6-7.5 in motor
3.5 in. motor
6-7.5 in motor
Wet-Cup O-Ring Package of 10 24A630 24A631 24A631 24A632 24A633 24A633
Coupling Collars (10) Package of 10 24A618 24A619
Connecting Kit Includes pump adapter (3), three tie rods (5), three tie rod nuts (6), TSL reservoir and o-ring (7), adapter (8), coupling nut (9), two coupling collars (10), tie rod shield and screw (11), and drip shield (12).
24A281 24A282 24A283 24A285 24A284 24A286 24A287 24A288 24A289
Repair Kits · Kit Description

10 20 30 40 50 60
(0.45)
(0.4)
(5.5, 55)
(0.34)
(0.28)
(0.23)
(0.17)
(0.1)
(1.4, 14)
(.06)
0.4 0.6 0.8 1.0 1.2 (1.5) (2.3) (3.0) (3.8) (4.5)
(0.75)
KEY A = 100 psi (0.7 MPa, 7 bar) B = 70 psi (0.5 MPa, 5 bar) C = 40 psi (0.3 MPa, 3 bar)
= fluid flow = air consumption Cycles per Minute
8 15 23 30 38 45 53
(0.25)
(0.23)
(0.2)
(0.17)
(0.14)
(5.5, 55)
(0.1)
(.08)
(.06)
(1.4, 14)
(.03)
0.05 0.1 0.15 0.2 0.25 0.3 0.35
(0.2) (0.4) (0.6) (0.75) (0.9) (1.1) (1.3)

8 15 23 30 38 45 53 61
(0.5) 1600 (11, 110)
(0.45)
(0.4)
(0.34)
B
(0.28)
(5.5, 55)
(0.23)
(0.17)
(0.1)
(1.4, 14)
(.06)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (0.4) (0.8) (1.1) (1.5) (1.9) (2.3) (2.6) (3.0)
KEY A = 100 psi (0.7 MPa, 7 bar) B = 70 psi (0.5 MPa, 5 bar) C = 40 psi (0.3 MPa, 3 bar)
= fluid flow = air flow
13 25 38 51 63
(1.1)
(0.9)
(5.5, 55)
(0.6)
(0.3)
(1.4, 14)
0.5 1.0 1.5 2.0 2.5 (1.9) (3.8) (5.7) (7.6) (9.5)

15 30 45 61
(1.1)
B
(0.9)
(0.6)
(5.5, 55)
(0.3)
0.5 1.0 1.5 2.0 (1.9) (3.8) (5.7) (7.6)
KEY A = 100 psi (0.7 MPa, 7 bar) B = 70 psi (0.5 MPa, 5 bar) C = 40 psi (0.3 MPa, 3 bar)
= fluid flow = air flow
8 15 23 30 38 45 53 61
Air Flow scfm (m 3 /min)
(1.1)
(0.9)
B
(0.6)
(0.3)
0.2 (0.75)
0.4 0.6 0.8 1.0 (1.5) (2.3) (3.0) (3.8)
1.2 1.4 1.6 (4.5) (5.3) (6.1)

13 25 38 51 63
70 (2.0)
(1.7)
B
(1.4)
(1.1)
(0.9)
(0.6)
(0.3)
1.5 2.0 2.5 (1.9) (3.8) (5.7) (7.6) (9.5) 0.5 1.0
KEY A = 100 psi (0.7 MPa, 7 bar) B = 70 psi (0.5 MPa, 5 bar) C = 40 psi (0.3 MPa, 3 bar)
= fluid flow = air flow
15 30 45 61 3000 (21, 210)
(1.7)
(1.4)
(1.1)
(0.9)
(0.6)
(0.3)
1.5 2.0 2.5 (1.9) (3.8) (5.7) (7.6) (9.5) 0.5 1.0

8 15 23 30 38 45 53
(0.5)
(0.45)
(0.4)
(0.34)
B
(0.28)
(0.23)
(0.17)
(0.1)
(.06)
0.05 0.1 0.15 0.2 0.25 0.3 0.35
0.4 (1.5)
(0.2) (0.4) (0.6) (0.75) (0.9) (1.1) (1.3)
KEY A = 100 psi (0.7 MPa, 7 bar) B = 70 psi (0.5 MPa, 5 bar) C = 40 psi (0.3 MPa, 3 bar)
= fluid flow = air flow
10 20 30 40 50 60
(1.1)
B
(0.9)
(0.6)
(0.3)
0.2 (0.75) 0.4 0.6 0.8 1.0 (1.5) (2.3) (3.0) (3.8) 1.2 (4.5)

8 15 23 30 38 45 53 61
(1.7)
(1.4)
(1.1)
B C
(0.9)
(0.6)
(0.3)
0.2 (0.75)
0.4 0.6 0.8 1.0 (1.5) (2.3) (3.0) (3.8) (4.5) (5.3) (6.1) 1.2 1.4 1.6
KEY A = 100 psi (0.7 MPa, 7 bar) B = 70 psi (0.5 MPa, 5 bar) C = 40 psi (0.3 MPa, 3 bar)
= fluid flow = air flow
8 15 23 30 38 45 53 61
(1.4)
(1.1)
B
(0.9)
(0.6)
(0.3)
0.4 0.6 0.8 (1.5) (2.3) (3.0) 0.1 0.3 (0.4) (1.1) (1.9)
0.2 (0.75)
0.5 0.7 (2.6)

10 20 30 40 50 60
Air Flow scfm (m 3 /min)
(1.7)
(1.4)
B
(1.1)
(0.9)
(0.6)
(0.3)
0.2 (0.75) 0.4 0.6 0.8 1.0 (1.5) (2.3) (3.0) (3.8) 1.2 (4.5)
KEY A = 100 psi (0.7 MPa, 7 bar) B = 70 psi (0.5 MPa, 5 bar) C = 40 psi (0.3 MPa, 3 bar)
= fluid flow = air flow



A in. (mm)
B in. (mm)
W10xxx 24.6 (625) 5.6 (142) 5.8 (147) 7.8 (198) 30 (14)
W15Axx 24.1 (612) 4.2 (107) 5.1 (130) 6.2 (157) 15 (7)
W15Bxx 24.0 (610) 5.6 (142) 5.8 (147) 7.8 (198) 28 (13)
W15Fxx 25.2 (640) 8.6 (218) 11.7 (297) 11.4 (290) 61 (28)
W18xxx 25.2 (640) 8.6 (218) 11.7 (297) 11.4 (290) 61 (28)
W23xxx 25.1 (638) 8.6 (218) 11.7 (297) 11.4 (290) 59 (27)
W24xxx 25.2 (640) 10.1 (257) 14.8 (375) 12.9 (328) 64 (29)
W28xxx 25.2 (640) 10.1 (257) 14.8 (375) 12.9 (328) 64 (29)
W30Axx 24.1 (612) 5.6 (142) 5.8 (147) 7.8 (198) 22 (10)
W30Cxx 25.0 (635) 8.6 (218) 11.7 (297) 11.4 (290) 56 (26)
W36xxx 25.1 (638) 10.1 (257) 14.8 (375) 12.9 (328) 62 (28)
W45xxx 24.5 (622) 8.6 (218) 11.7 (297) 11.4 (290) 54 (25)
W48xxx 25 (635) 10.1 (257) 14.8 (375) 12.9 (328) 59 (27)

Wall Bracket Mounting Dimensions
11 in. (279 mm)
4 in. (102 mm)
Four 0.40 in. (10 mm) mounting holes
Maximum fluid working pressure See Models, page 4 Maximum air inlet pressure See Models, page 4 Minimum air inlet pressure 10 psi (0.07 MPa, 0.7 bar) Air consumption See Performance Charts Fluid flow at 60 cycles per minute See Models, page 4 Maximum ambient air temperature 120°F (49°C) Maximum fluid temperature 160°F (71°C) Stroke length 2.5 in. (63.5 mm) Sound data See Technical Data in air motor manual 312796. Wetted parts Stainless steel, tungsten carbide with 6% nickel,

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 312794
Copyright 2008, Graco Inc. is registered to ISO 9001
Revised 5/2010
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Pump output low on both strokes. | Restricted air supply lines. | Clear any obstructions; be sure all shutoff valves are open; increase pressure, but do not exceed maximum working pressure. | p.14 |
| Pump output low on both strokes. | Exhausted fluid supply. | Refill and reprime pump. | p.14 |
| Pump output low on both strokes. | Clogged fluid outlet line, valves, etc. | Clear. | p.14 |
| Pump output low on both strokes. | Worn piston packing. | Replace. See displacement pump manual 312792. | p.14 |
| Pump output low on only one stroke. | Held open or worn ball check valves. | Check and repair. | p.14 |
| Pump output low on only one stroke. | Worn piston packings. | Replace. | p.14 |
| No output. | Improperly installed ball check valves. | Check and repair. | p.14 |
| Pump operates erratically. | Exhausted fluid supply. | Refill and reprime pump. | p.14 |
| Pump operates erratically. | Held open or worn ball check valves. | Check and repair. | p.14 |
| Pump operates erratically. | Worn piston packing. | Replace. | p.14 |
| Pump will not operate. | Restricted air supply lines. | Clear any obstructions; be sure all shut off valves are open; increase pressure, but do not exceed maximum working pressure. | p.14 |
| Pump will not operate. | Exhausted fluid supply. | Refill and reprime pump. | p.14 |
| Pump will not operate. | Clogged fluid outlet line, valves, etc. | Clear. | p.14 |
| Pump will not operate. | Damaged air motor. | See air motor manual 312796. | p.14 |
| Pump will not operate. | Fluid dried on piston rod. | Disassemble and clean pump. See page 15 and manual 312792. In future, stop pump at bottom of stroke. | p.14 |
| Pump will not operate. | Runaway solenoid has tripped. | Retract solenoid. See air motor manual 312796. | p.14 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.