ProMix ® 2KS
Plural Component Proportioner
Manual system for proportional mixing of plural component coatings. For professional use only.
Approved for use in explosive atmospheres (except the EasyKey).
See page 4 for model information, including maximum working pressure. Equipment approval labels are on page 3. Some components shown are not included with all systems.

TI12504a · # 53


Equipment Approvals
Component Manuals in English
EasyKey and Fluid Station Label
ATEX Certificate is listed here

!"#$#%% & ' ( ( )* + ) , - ( + . /+0 1% 2* 3
2 1 3/% 1 4 5 6 '( # &'(
3 ( ( 9 88 $$!% +1 &&88

Intrinsically safe equipment for Class I, Div 1, Group D, T3 Ta = -20°C to 50°C Install per 289833 FM08ATEX0073 II 2 G Ex ia IIA T3
GRACO INC. P.O. Box 1441 Minneapolis, MN 55440 U.S.A.
ATEX Certificate is listed here

Intrinsically safe connections for Class I, Div 1, Group D Ta = -20°C to 50°C Install per 289833 C US 50/60 Hz
GRACO INC. P.O. Box 1441 Minneapolis, MN 55440 U.S.A. II (2) G [Ex ia] IIA FM08ATEX0072
ATEX Certificate is listed here
Related Manuals · Fluid Station Label · EasyKey Label

System Configuration and Part Numbers
Configurator Key


!"#$" %#$!
!"#$#%% & ' ( ( )* + ) , - ( + . /+0 1% 2* 3
( 78 3 4
Label Location on EasyKey Label Location on Fluid Station
$#$+" , +-! !./%0!$# - ( ++ 1
2 1 3/% 1 4 5 6 '( # &'(
Maximum Fluid Working Pressure
3 ( ( 9 88 $$!% +1 &&88
&'( ) '*

System Configuration and Part Numbers
Models using a G3000, G3000HR, or intrinsically safe Coriolis meter for both A and B meters are approved for installation in a Hazardous Location - Class I, Div I, Group D, T3 or Zone I Group IIA T3.
Maximum working pressure rating is dependent on the fluid component options selected. The pressure rating is based on the rating of the lowest rated fluid component. Refer to the component pressure ratings below. Example: Model MD2531 has a maximum working pressure of 3000 psi (21 MPa, 210 bar).
Check the identification label on the EasyKey or fluid station for the system maximum working pressure. See FIG. 1.
ProMix Fluid Components Maximum Working Pressure
Base System (no meters [option 0], no color/catalyst change [option 0]) 4000 psi (27.58 MPa, 275.8 bar) Meter Option 1 and 2 (G3000 or G3000HR) 4000 psi (27.58 MPa, 275.8 bar) Meter Option 3, 4, 5, 6, and 7 (one or two Coriolis Meters) 2300 psi (15.86 MPa, 158.6 bar) Color Change Option 1, 2, 3 and 4 and Catalyst Change Option 1 and 2 (low pressure valves) 300 psi (2.07 MPa, 20.6 bar) Color Change Option 5 and 6 and Catalyst Change Option 3 (high pressure valves) 3000 psi (21 MPa, 210 bar)
Flow Meter Fluid Flow Rate Range
G3000 75-3800 cc/min. (0.02-1.0 gal./min.) G3000HR 38-1900 cc/min. (0.01-0.50 gal./min.) Coriolis Meter 20-3800 cc/min. (0.005-1.00 gal./min.) S3000 Solvent Meter (accessory) 38-1900 cc/min. (0.01-0.50 gal./min.)
Fiber Optic and Power Cables, 50 ft (15.25 m)
Wall Mount Fluid Station, 50 cc Integrator and Static Mixer
B Side Dump Valve, if multiple catalyst valves

Gun Flush Box Gun Insert Selection
15V354 Third Purge Valve Kit
15V536 Solvent Flow Switch Kit
15V213 Power Cable, 100 ft (30.5 m)
15G710 Fiber Optic Cable, 100 ft (30.5 m)
15U955 Injection Kit for Dynamic Dosing
15V034 10 cc Integrator Kit
15V033 25 cc Integrator Kit
15V021 50 cc Integrator Kit
24B618 100 cc Integrator Kit
15W034 Strobe Light Alarm Indicator Kit
15V337 Advanced Web Interface
15V256 Automatic Mode Upgrade Kit
16D329 S3000 Solvent Flow Meter Kit
15V825 Discrete I/O Integration Board Kit
Accessories · Accessory

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.


Isocyanate Conditions
Moisture Sensitivity of Isocyanates
Isocyanates (ISO) are catalysts used in two component coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in vis- cosity. If used, this partially cured ISO will reduce perfor- mance and the life of all wetted parts.
Spraying or dispensing materials containing isocya- nates creates potentially harmful mists, vapors, and atomized particulates.
Read material manufacturer’s warnings and mate- rial MSDS to know specific hazards and precautions related to isocyanates.
Prevent inhalation of isocyanate mists, vapors, and atomized particulates by providing sufficient ventila- tion in the work area. If sufficient ventilation is not available, a supplied-air respirator is required for everyone in the work area.
To prevent exposing ISO to moisture:
To prevent contact with isocyanates, appropriate personal protective equipment, including chemically impermeable gloves, boots, aprons, and goggles, is also required for everyone in the work area.
Some materials may become self-igniting if applied too thickly. Read material manufacturer’s warnings and material MSDS.
Cross-contamination can result in cured material in fluid lines which could cause serious injury or dam- age equipment. To prevent cross-contamination of the equipment’s wetted parts, never interchange component A (isocyanate) and component B (resin) parts.

Advanced Web Interface (AWI) - This allows remote ProMix backup and restore, configuration, logging, and software update options.
Coriolis Meter - a non-intrusive flow meter often used in low flow applications or with light viscosity, shear sensi- tive, or acid catalyzed materials. This meter uses vibra- tion to measure flow.
Air Chop - the process of mixing air and solvent together during the flush cycle to help clean the lines and reduce solvent usage.
Custom Language - A method to load a translation file into the ProMix to display languages other than those built into the system. Only Unicode characters through codespace 0x00FF are supported.
Air Chop Time- duration of each activation of the air purge valve during a chop sequence. User settable from 0.0-99.9 seconds.
Digital Input and Output - a description of data which is transmitted as a sequence of discrete symbols, most commonly this means binary data represented using electronic or electromagnetic signals.
Analog - relating to, or being a device in which data are represented by continuously variable, measurable, physical quantities, such as length, width, voltage, or pressure.
Discrete I/O - refers to data that constitutes a separate entity and has direct communication to another control.
B Purge After Chop - Optional 2-second B solvent valve activation after the Chop sequence. This is used to separate the chop material and the Final Purge mate- rial to prevent unwanted mixing.
Dose Size - the amount of resin (A) and catalyst (B) that is dispensed into an integrator.
Dose Time Alarm - the amount of time that is allowed for a dose to occur before an alarm occurs. More than 30 pulses from the flow meter of the active dose valve are needed while the Gun Trigger is on to prevent the alarm.
Basic Web Interface (BWI) - This allows remote Pro- Mix backup and restore, logging, and software update options.
Bootloader - The utility program that handles initial sys- tem startup re-programming of the main ProMix applica- tion.
Dynamic Dosing - Component A dispenses constantly. Component B dispenses intermittently in the necessary volume to attain the mix ratio.
Chop Time- refers to the total length of the chop sequence during a purge. User settable from 0-999 sec- onds.
Ethernet - a method for directly connecting a computer to a network or equipment in the same physical location.
Closed Loop Flow Control - refers to the process when the flow rate is adjusted automatically to maintain a constant flow.
ExtSP - External Set Point selection for PLC input of the flow rate set point while operating in Flow Control Over- ride mode.
Color/Catalyst Purge - refers to the time required to flush the lines from the color or catalyst change module to the mix manifold during a color or catalyst change.
Fiber Optic Communication - the use of light to trans- mit communication signals. Blue is the transmitter, and black is the receiver. This must be cross-connected between the EasyKey and the Fluid Panel for communi- cation to work. The Fiber Optic cable has a blue band to indicate the proper connection.
Color/Catalyst Fill - refers to the time required to fill the lines from the color or catalyst change module to the mix manifold.
Final Purge Source- source of the media used in the final purge cycle. User settable to air purge valve, sol- vent purge valve, or 3rd purge valve.
Command Holdoff - The amount of time that flow rate learning is not allowed after the set point is changed to allow the flow rate to stabilize.
Final Purge Time- duration of the final purge cycle. User settable from 0-999 seconds.
Glossary of Terms

First Purge Source- source of the media used in the first purge cycle. User settable to air purge valve, sol- vent purge valve, or 3rd purge valve
K-factor - a value that refers to the amount of material that passes through a meter. The assigned value refers to an amount of material per pulse.
First Purge Time- duration of the first purge cycle. User settable from 0-999 seconds.
Kd - refers to the amount the fluid flow system attempts to not overshoot the target set point.
Flow Control Resolution - a settable value that allows the flow control system to maximize its performance. The value is based on maximum desired flow rates.
Ki - refers to the degree fluid flow over shoots its set point.
Kp - refers to the speed in which the fluid flow reaches its set point.
Flow Rate Analog Signal - the type of communication signal that can be used on the ProControl module.
Learn Strength - How much and how quickly to apply the difference in the flow rate set point compared to the measured flow rate when updating the flow control data table.
Flow Rate Tolerance - the settable percent of accept- able variance that the system will allow before a flow rate warning occurs.
Flow Set Point - a predefined flow rate target.
Manual Mode - when the proportioning or flow control system is controlling the inputs without any input from an outside control.
Flush Volume Check - system monitors flush volume. E-11 Alarm occurs if minimum volume is not achieved. Minimum flush volume is user settable (0-999 cc).
Minimum Material Fill Volume - system monitors material fill volume. E-21 Alarm occurs if minimum vol- ume is not achieved. Minimum material fill volume is user settable (0-9999 cc).
Global - indicates that values on the screen apply to all recipes, 1 through 60.
Grand Total - a non-resettable value that shows the total amount of material dispensed through the system.
Mix - when cross-linking of the resin (A) and catalyst (B) occurs.
GT-Off Drive Time - The amount of time to regulate the fluid pressure based on the flow rate set point after the gun trigger is closed.
Mix Fill Push - An option for the Autodump selection to automatically clear the Potlife alarm if the gun is in the Gun Flush Box by running new mixed material through the gun.
GT-Off Target Rise - The additional time to regulate the fluid pressure based on the flow rate set point after the gun trigger is closed.
Mix Input Signal- refers to system mode status where system begins a dose sequence each time the mix sig- nal is made “High”.
Gun Trigger Holdoff - The amount of time that flow rate learning is not allowed after the gun trigger is opened to allow the flow rate to stabilize.
Mixed Material Fill Time - the amount of time that is required to load mixed material from the dose valves to the applicator/gun.
Gun Trigger Input Signal - used to manage ratio assurance dose times and flow control processes.
Modbus/TCP - a type of communication protocol used to communicate Digital I/O signals over an ethernet.
Intrinsically Safe (IS) - refers to the ability to locate cer- tain components in a hazardous location.
Network Station - a means to identify a particular indi- vidual proportioning or flow control system.
Idle - if the gun is not triggered for 2 minutes the system enters Idle mode. Trigger the gun to resume operation.
One-Point Learning - Flow Control table calibration method using learned points above a specified flow rate to interpolate the table at low flow rates with short gun trigger times.
Job Total - a resettable value that shows the amount of material dispensed through the system for one job. A job is complete when a color change or complete system flush occurs.
Glossary of Terms

Overdose (A, B, C) Alarm - when either the resin (A), or catalyst (B), or reducer (C) component dispenses too much material and the system cannot compensate for the additional material.
Third Purge Valve - refers to the use of three purge valves used to flush some waterborne materials. The valves are used to flush with water, air and solvent.
V/P - refers to the voltage to pressure device in the flow control module.
Potlife Time - the amount of time before a material becomes unsprayable.
Valve Holdoff Maximum - The maximum amount of time that flow rate learning is not allowed after a dose valve cycles. The system may internally use a time less than is based on the stability of the fluid meter pulse stream.
Potlife Volume - the amount of material that is required to move through the mix manifold, hose and applicator before the potlife timer is reset.
Purge - when all mixed material is flushed from the sys- tem.
Purge Drive - The voltage drive during the Purge sequence, maximum of 3300 mV. The response curve of the V/P regulator is not linear, so it may be necessary to test the response using Manual Override mode.
Purge Time - the amount of time required to flush all mixed material from the system.
Purge Volume Alarm - E-11 Alarm occurs if minimum flush volume is not achieved.
Ratio Tolerance - the settable percent of acceptable variance that the system will allow before a ratio alarm occurs.
Sequential Color Change - the process when a color change is initiated and the system automatically flushes the old color and loads a new color.
Sequential Dosing - Components A and B dispense sequentially in the necessary volumes to attain the mix ratio.
Solvent/3rd Purge Valve Chop Time- duration of each activation of the solvent or 3rd purge valve during a chop sequence. User settable from 0.0-99.9 seconds.
Solvent Fill - the time required to fill the mixed material line with solvent.
Solvent Push - enables the user to save some mixed material by pushing it out to the gun with solvent. Requires an accessory solvent meter.
Standby - refers to the status of the system.
System Idle - This warning occurs if the ProMix is set to Mix, and 2 minutes have elapsed since the system received a flow meter pulse.
Glossary of Terms

Usage
The Graco ProMix 2KS is an electronic two-component paint proportioner. It can blend most two-component solvent and waterborne epoxy, polyurethane, and acid-catalyzed paints. It is not for use with “quick-setting” paints (those with a potlife of less than 15 minutes).
See Table 1, FIG. 2, and FIG. 3 for the system components.
EasyKey (EK) Used to set up, display, operate, and monitor the system. The EasyKey accepts 85-250 VAC, 50/60 Hz line power and converts that power to acceptable low voltage and optical signals used by other system components.
Booth Control (BC) Used by the operator for daily painting functions including: choosing recipes, initiating job complete, reading/clearing alarms, and placing the system in Standby, Mix, or Purge mode. It is typically mounted inside the booth or near the painter.
Fluid Station (ST) Includes air control solenoids, flow switches, and mountings for the fluid flow meters and the fluid manifold assembly. Its control board manages all proportioning functions.
Fluid Integrator is the chamber where component A and B align at the selected ratio and begin to mix. Static Mixer has 24 elements to uniformly blend the materials downstream of the fluid integrator.
Overview · Component Description

Three optional flow meters are available from Graco:
Flow Meters (MA, MB, MS)
1/8 in. fluid passages: set K-factor to .020 or .061. 3/8 in. fluid passages: set K-factor to .061 or 0.119.
Color Change Valves (ACV) and Color Change Module (CCM)
An optional component. It is available as a color change valve stack for either low or high pressure with up to 30 color change valves. Each stack includes one additional valve for solvent to clean the fluid line between color changes.
An optional component. It is available as a catalyst change valve stack for either low or high pressure with up to 4 catalyst change valves. Each stack includes one additional valve for solvent to clean the fluid line between catalyst changes.
Catalyst Change Valves (BCV)
Dual Fiber Optic Cable (FO)
Used to communicate between the EasyKey and Wall Mount Fluid Station.
Used to provide power to the Wall Mount Fluid Station.
Fluid Station Power Supply Cable (PS)
Air Flow Switch: The air flow switch detects air flow to the gun and signals the ProMix controller when the gun is being triggered. The switch functions with the flow meters to ensure that the system components are functioning correctly. See page 52 for further information.
Gun Flush Box: The gun flush box kit provides an automated flushing system for manual spray guns, and includes an air flow switch.
Overview · Component Description

CCM
PS
BC
BCV
FO
ACV
MS
ST
MA
MB
FM GFB
FIG. 2. Manual System, shown with G3000 Meters, Color/Catalyst Change, One Gun Flush Box, and Accessory Solvent Flow Meter
Overview · TI12504a

FI
MB DVB

MA
RVB
AT
APV
RVA
SVA SVB
SM
SPV
FIG. 3. Wall Mount Fluid Station
Key: MA Component A Meter DVA Component A Dose Valve RVA Component A Sampling Valve SVA Component A Shutoff Valve MB Component B Meter DVB Component B Dose Valve RVB Component B Sampling Valve SVB Component B Shutoff Valve MS Solvent Meter (accessory) SPV Solvent Purge Valve APV Air Purge Valve SM Static Mixer FI Fluid Integrator AT Air Purge Valve Air Supply Tube
Overview · TI12556b

Used by the operator for daily painting functions includ- ing: changing recipes, signalling job complete, read- ing/clearing alarms, and placing the system in Standby, Mix, or Purge mode. It is typically mounted inside the booth or near the painter.
(see FIG. 4)

(see FIG. 4)
Key/Indicator Definition and Function

Up or Down keys, then
pressing Enter .
Alarm Reset Key and Indicator
Job Complete Key and Indicator
Enter Key Enters selected recipe and starts color change sequence.
FIG. 4. Booth Control (see Table 2)

EasyKey Display and Keypad

Navigation Keys Alarm Reset Key
FIG. 5. EasyKey Display and Keypad
Shows graphical and text information related to setup and spray operations. Back light will turn off after 10 minutes without any key press. Press any key to turn back on.

Enter: if cursor is in menu box, press Enter key to view menu. Press Enter to save a value either keyed in from the numerical keypad or selected from a menu.
Up Arrow: move to previous field or menu item, or to previous screen within a group.
Down Arrow: move to next field or menu item, or to next screen within a group.
Used to input numerical data, enter setup screens, scroll through screens, and select setup values.
In addition to the numbered keys on the EasyKey key- pad, which are used to enter values in setup, there are keys to navigate within a screen and between screens, and to save entered values. See Table 3.
Alarm Reset: resets all active alarms. If the display becomes unresponsive, pressing this key 4 times in succession will re-initialize the display.
Keypad LCD Display

EasyKey Display and Keypad
Audible Alarm Fiber Optic Strain Relief Port

Main Power Access Port
I/S Power Discrete I/O Cable Connector Ports Ground Screw
FIG. 6. EasyKey Connections and AC Power Switch
Graco Web Interface Port
Turns system AC power on or off.
Used to communicate from a PC to:
Power circuit to Fluid Station.
Alerts the user when an alarm occurs. Available settings for selecting which alarms will cause an audible alarm are explained in Configure Screen 1, page 29.
Clear the audible alarm by pressing the Alarm Reset
See manual 313386 for more information.
key.
Even after the Alarm Reset key is pressed, the Potlife Exceeded alarm message will remain displayed until a sufficient amount of mixed material has been dispensed to ensure that the expired material has been ejected.
You can access data on an office or industrial network through the internet with the proper configuration. See manual 313386 for more information.
AC Power · Graco Web Interface · TI12638a TI12657a

At power up, the Graco logo and software revision will display for approximately 5 seconds, followed by the
Status Screen (see page 22).

FIG. 7. Splash Screen
The Splash screen will also momentarily display “Estab- lishing Communication.” If this display remains for more than one minute, check that the fluid station circuit board is powered up (LED is on) and that the fiber optic cable is properly connected (see installation manual).

FIG. 8. Fluid Plate Programming Screen
Run Mode Screens




Press the Setup key to enter Setup mode.








FIG. 9. Run Screens Map
Run Mode Screens · TI12783a

Potlife Timer: shows remaining potlife time in min- utes. Two times are shown if there are two guns.
Status Bar: shows current alarm or operation mode (standby, mix, purge, recipe change, or the current alarm).
from the Status screen.
Current Flow Rate: in cc/min.
Animation: when the gun is triggered, the gun appears to spray and the component A or B hose lights up, showing which component dose valve is open.

Current Date and Time
Screen Number and Scroll Arrows: displays the current screen number and the total number of screens in a group. The Up and Down arrows on the right edge of the screen indicate the scroll feature. The total number of screens in some groups may vary depending on system configuration selections.
Lock Symbol: indicates that Setup screens are password protected. See page 26. FIG. 10. Status Screen
Key to FIG. 10:
Active Recipe: shows the active recipe.
Target Ratio: for the active recipe. The ratio can be from 0.0:1–50.0:1, in 0.1 increments.
Actual Ratio: in hundredths, calculated after each dose of A and B.
Run Mode Screens

Reset Total Screen
FIG. 11. Totals Screen
FIG. 12. Reset Total Screen
This screen shows the job totals, fill totals, grand totals, and job number. Use the tabs to reset job totals (Job Complete), reset solvent totals (Rst Solvent), or go to Level Control Screen, page 24.
If job is reset, job number will increment by one for default.
The job totals generally refer to material dispensed while in Mix mode. This is likely atomized and sprayed material with the gun trigger “On”.
The fill totals generally refer to material dispensed while in Mix-fill mode after a color change or a purge opera- tion. This is likely not sprayed or atomized, and is dis- pensed to a purge container.
Solvent Totals and the Rst Solvent tab only appear if “Meter” is selected under Solvent Monitor in Configure Screen 5 on page 31.
FIG. 13. Reset Solvent Total Screen
The screen will ask if you want to reset solvent total. Select Yes or No.
Run Mode Screens

occur after 25% of the remaining volume is mixed. Refill tank volume to clear the alarm.

FIG. 14. Alarms Screen
FIG. 16. Tank Level Low Screen (Tank A Shown)
Two screens show the last 10 alarms. Use the Up or
Down keys to scroll between the two screens.
See Table 10 on page 80 for a list of alarm codes.
FIG. 15. Level Control Screen
This screen shows the current volume for each fluid. Adjust the current volumes on this screen, or use the tab to go to Usage (Totals Screen, page 23). The Alarm Level values may be adjusted using the advanced web interface.
See FIG. 16. If the tank volume reaches the low-level threshold, the EasyKey screen will display the Tank Level Low alarm and prompt the user to do one of the following:
Run Mode Screens

Press the Setup key to enter Setup mode. NOTE: See FIG. 17 for a map of the Setup screens. Detailed screen descriptions follow.

Press the Setup key to enter Setup mode.




This screen appears only if a
password is activated.




To access Advanced Setup Screens, page 34
and Recipe Setup Screens, page 38.
To access System Configuration
Screens, page 28.

Press the Setup key to exit Setup mode and return to the Status
screen.



This screen appears momentarily
if a password is activated.

FIG. 17. Setup Screens Map
Setup Mode · TI12784a

Set Up Home Screen
If a password has been activated (see Configure Screen 1, page 29), the Password screen will appear. You must enter the password to access the Set Up Home Screen. Entering the wrong password returns the display to the Status Screen.
FIG. 20. Set Up Home Screen
This screen displays when you enter Setup mode. From it you can go to Recipe and Advanced Setup Screens (pages 34-42) or System Configuration Screens
(pages 28-31). Press the Enter key to go to the selected screen set.
FIG. 18. Password Screen
The screen also displays software versions and internet addresses of various components. The values shown in FIG. 20 are only examples and may vary on your screen. See Table 4 for further information.
ing to the Status Screen. A lock symbol appears
on the Status Screen.
FIG. 19. Setup Locked Screen
Setup Mode

Display (may vary from examples shown) Description
EK (EasyKey) 3.01.001 EasyKey software version.
FP (Fluid Plate) 3.01.001 Fluid Plate software version.
BC (Booth Control) -.- Booth Control not installed, not detected, or not operational.
1.XX Booth Control software version 1.00 or 1.01.
2.XX Booth Control software version 2.XX.
C1/C2 (Color Change Modules 1 and 2)
-.- Color Change Module 1/2 not installed, not detected, or not operational.
1.XX Color Change Module software version 1.00 or 1.01.
2.XX Color Change Module software version 2.XX.
AK (Autokey) No Key No AutoKey installed or detected. System operates in 2K Manual Mode only
2K-Auto 2K AutoKey detected. System can operate in 2K Manual, Semi-automatic, or Automatic Mode.
3K-Auto 3K AutoKey detected. System can operate in 3K Manual, Semi-automatic, or Automatic Mode.
XP (XPORT) V6.6.0.2 Example of XPORT network module software version. Other versions are acceptable.
MC (Micro Controller) 1042.0198 Example of fluid plate micro controller version. Other versions are acceptable.
Axx By Cz A30 B4 Cx Color Change board valve configuration. This shows the num- ber of valves available for each of the components. This is set by the configuration switches on the color change boards connected to the system.
- Component not available with this machine configura- tion.
x Component not used with this machine configuration.
1 Component available but no change stack.
4-30 Component available with change stack. Number of valves flushed with a solvent valve.
IP (Internet Address) 192.168.178.3 Example of the address EasyKey is set to for basic and advanced web interface reporting.
MAC (MAC address) 00204AAD1810 Example of internet MAC address. Each EasyKey will have a different value in this format.
Setup Mode · Component · Code Description











FIG. 21. System Configuration and Option Screens Map
Setup Mode · TI12785a

Select the desired screen timeout in minutes (0-99). 5 is the default.
FIG. 22. Configure Screen 1
Defines the language of the screen text. Select English (default), Spanish, French, German, Italian, Dutch, Jap- anese (Kanji), Korean, Chinese (Simplified), and Cus- tom.
FIG. 23. Configure Screen 2
Enter current month.
Enter current day.
The password is only used to enter Setup mode. The default is 0, which means no password is required to enter Setup. If a password is desired, enter a number from 1 to 9999.
Enter current year (four digits).
Enter current time in hours (24 hour clock), minutes, and seconds. Seconds are not adjustable.
Select MM-DD-YYYY, DD-MM-YYYY, or YYYY-MM-DD.
Select the desired display units:
As the default, the alarm buzzer is set to “Potlife Only” and will sound only for the Potlife Alarm (E-2).
Set to “All Alarms” to have the buzzer sound for any alarm.
Set to “All Except Potlife” to have the buzzer sound for any alarm except a Potlife Alarm (E2). This option is not recommended unless another active method of handling the Potlife Alarm is implemented.

Configure Screen 4
FIG. 24. Configure Screen 3
FIG. 25. Configure Screen 4
Set this value to indicate the system performance level designation. Selecting a value other than the installed system level will result in restricted functionality.
Enter the dose time (1 to 99 seconds). This is the amount of time allowed for a dose to occur before a dose time alarm occurs.
Select the total dose size (cc) from the pulldown menu: 100, 50, 25, 10, or select DD to turn on dynamic dosing (see page 48).
Indicates that this is a Manual system.
Example: For a total dose size of 50 cc and a ratio of 4.0:1, the component A dose size is 40 cc and component B dose size is 10 cc.
This field only appears if the color change option is detected from the cc board. Select “On” if an optional Dump Valve A is installed and desired to be used.
This field only appears if the catalyst change option is detected from the cc board, meaning that dump valve B is present. On is the only setting.
Enter the number of spray guns (1 or 2).
Off is default. If the system includes an optional 3rd flush valve, set to On.
Enter the number of gun flush boxes (Off, 1, or 2).
See Fig. 26 and Fig. 27 on page 31.


Use of Special Outputs on Manual systems requires installation of a Discrete I/O Integration Board. Order Graco Part No. 15V825 Discrete I/O Integration Board Kit. See manual 406800.
Select special outputs (0-4, or 3 + GFB on #4). A selec- tion of “0” will disable use of the Special Outputs. If the “3 + GFB on #4” selection is chosen, the other 3 special outputs (1-3) can be used for user-defined functions and the special output #4 settings will duplicate those set- tings established for the Gun Flush Box.
FIG. 26. Configure Screen 4, dynamic dosing selected

Each output has two different start times and durations defined on the Recipe Setup screen (Flush and Fill Input is set to “Recipe” in Option Screen 1, page 32), or on the Advanced Setup screen (Flush and Fill Input is set to “Global” in Option Screen 1, page 32).
Select solvent monitor (Off, Flow Switch, or Meter).
A selection of “Meter” will cause the system to track the amount of solvent used. See Totals Screen, page 23 for more information about solvent totals.
FIG. 27. Configure Screen 4, dynamic dosing setup mode enabled
The default web browser IP address prefix is 192.168.178.__ Assign a unique number for each EasyKey in your system (1-99) and enter it here.
Selecting “DD” in the Dose Size field makes the Dynamic Dosing setup mode field appear. Select On to enable DD setup mode, or Off to disable. See page 49 for further information.
Used for the Graco Gateway network system. See Graco Gateway manual 312785 for further information.
FIG. 28. Configure Screen 5

Minimum Material Fill Volume
Enter 0-9999 cc.
Option Screen 1
FIG. 30. Verification Screen
FIG. 29. Option Screen 1
This screen appears if Flush and Fill Input or K-factor Input are changed from “Recipe” to “Global” in Option Screen 1.
This field only appears if Solvent Monitor is set to “Meter” in Configure Screen 5, page 31.
If set to “On”, Minimum Flush Volume will appear in Recipe Setup Screen 2, page 39.
Flush and Fill Input
If set to “Global”, Color/Catalyst Purge and Color/Cata- lyst Fill are added to Advanced Setup Screen 1, page 35. Advanced Setup Screen 2, 3, and 5 are added. See pages 35-37.
If set to “Recipe”, Color/Catalyst Purge and Color/Cata- lyst Fill are added to Recipe Setup Screen 2, page 39. Recipe Setup Screen 3, 4, and 7 are added. See pages 40-42.
Global mode is useful when the material properties, flush and fill characteristics, or K-factors are the same for all materials used by the system.
If set to “Global,” Advanced Setup Screen 4, page 36 is added.
If set to “Recipe,” Recipe Setup Screen 5, page 41, is added.

B Purge After Chop
Optional 2-second burst (2 s B) operation of the B Purge valve on the integrator after the Chop cycle.
See Color Change Sequences, page 67 for color change charts and timing information.
FIG. 31. Option Screen 2
If the auto dump feature is being used, set to “Solvent Push” or “Mix Fill Push”. Once the auto dump is enabled, the gun flush box is enabled and the potlife alarm is active for 2 minutes, the system will automati- cally flush or push out the old material based on the selected option.
“Solvent Push” will flush out expired material using the solvent supply. See Solvent Push Feature on page 63 for more information.
“Mix Fill Push” will push out expired material with new mixed material. When sufficient material has been pushed, the potlife alarm will reset. See Mix Fill Push Feature on page 64 for more information.
If set to “On,” Recipe Setup Screen 6 on page 41 is added, enabling setting of high and low flow limits.
If set to “Off,” flow rate monitoring is disabled and Rec- ipe Setup Screen 6 on page 41 will not appear.
To enable the Solvent Push feature, select “Solvent” or “3rd Valve” (available if 3rd Flush Valve in Configure Screen 3, page 30, is set to “On”).
To disable the Solvent Push feature, set to “Off.”



Advanced Setup screens 2, 3, 4, and 5 appear depending on selections made in Option
screens 1 and 2.










FIG. 32. Advanced Setup Screens Map
Setup Mode · TI12786a

This field only appears if the system includes a color change module and Flush and Fill Input is set to “Global” in Option Screen 1, page 32. Enter the fill time (0 to 99 seconds). It refers to the time required to fill the lines from the color or catalyst module to the dose valve or dump valve.
Advanced Setup Screen 2
FIG. 33. Advanced Setup Screen 1
FIG. 34. Advanced Setup Screen 2
Gun 1/Gun2 Potlife Volume
Enter the potlife volume (1 to 1999 cc) for each gun. This is the amount of material required to move through the mix manifold, hose and applicator/gun before the potlife timer is reset.
This screen appears only if Flush and Fill Input is set to “Global” in Option Screen 1, page 32.
Select “Air,” “Solvent,” or “3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30).
Use the following information to determine approximate pot life volume (PLV) in cc:
Hose ID (inches) Volume (cc/foot)*
3/16 5.43 1/4 9.648 3/8 21.71
Select “Air/Solvent” or “Air/3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30). This refers to the process of mix- ing air and solvent (or air and 3rd flush fluid) together during the flush cycle, to help clean the lines and reduce solvent usage.
Integrator manifold and mixer volume = 75 cc Spray Gun Volume = 20 cc
(Hose Volume* x Feet of Hose) + 75 + 20 = PLV
Select “Air,” “Solvent,” or “3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30).
This field only appears if the system includes a color change module and Flush and Fill Input is set to “Global” in Option Screen 1, page 32. Enter the purge time (0 to 99 seconds). It refers to the amount of time required to flush the lines from the color or catalyst mod- ule to the dose valve or dump valve.
Enter the air chop time (0.0 to 99.9 seconds).
Solvent Chop Time/3rd Flush Valve Chop Time
Enter the solvent or 3rd flush valve chop time (0.0 to 99.9 seconds).

Advanced Setup Screen 4
FIG. 35. Advanced Setup Screen 3
FIG. 36. Advanced Setup Screen 4
This screen appears only if Flush and Fill Input is set to “Global” in Option Screen 1, page 32.
This screen appears only if K-factor Input is set to “Global” in Option Screen 1, page 32.
If Number of Guns is set to “2” in Configure Screen 4, page 30, a Gun 2 column will appear in this screen.
Enter the k-factor (cc/pulse) for flow meter A. This is the amount of material that passes through the flow meter per pulse (electrical pulse signal).
Enter the first purge time (0 to 999 seconds).
Enter the k-factor (cc/pulse) for flow meter B.
Enter the total chop time (0 to 999 seconds).
This field only appears if Solvent Monitor in Configure Screen 5, page 31, is set to “Meter.” Enter the k-factor (cc/pulse) for the solvent flow meter.
Enter the final purge time (0 to 999 seconds).
Mixed Material Fill Time
Enter the mixed material fill time (0 to 999 seconds). It refers to the amount of time that is required to load mixed material from the dose valves to the applica- tor/gun.

FIG. 37. Advanced Setup Screen 5
This screen appears only if Flush and Fill Input is set to “Global” in Option Screen 1, page 32 and Special Out- puts is set to 1, 2, 3, or 4 in Configure Screen 5, page 31. The I/O board has four programmable outputs.
Delay time at the start of the purge cycle before the Spe- cial Output turns on.
Duration for the Special Output to be active during the purge cycle.
Delay time at the start of the fill cycle before the Special Output turns on.
Duration for the Special Output to be active during the fill cycle.




















Recipe screens 3, 4, 5, 6, and
7 appear depending on selections made in Option
screens 1 and 2
Setup Mode · Recipe 0 Screens · TI12787a

FIG. 40. Recipe Setup Screen 2
Minimum Flush Volume This field only appears if Flush Volume Check is set to “On” in Option Screen 1 on page 32. Enter the mini- mum flush volume (0 to 9999 cc). Entering 0 disables this function.
FIG. 39. Recipe Setup Screen 1
Potlife Time Enter the potlife time (0 to 999 minutes). Entering 0 dis- ables this function.
Enter the mix ratio of component A over component B (0.0:1 to 50:1).
This field only appears if the system includes a color change module and Flush and Fill Input is set to “Rec- ipe” in Option Screen 1, page 32. Enter the purge time (0 to 99 seconds). It refers to the amount of time required to flush the lines from the color or catalyst mod- ule to the dose valve or dump valve.
Enter the ratio tolerance (1 to 99%). This refers to the percent of acceptable variance that the system will allow before a ratio alarm occurs.
Component A (Color) Valve (if present)
This field only appears if the system includes a color change module. Enter the color valve number (1 to 30).
This field only appears if the system includes a color change module and Flush and Fill Input is set to “Rec- ipe” in Option Screen 1, page 32. Enter the fill time (0 to 99 seconds). It refers to the time required to fill the lines from the color or catalyst module to the dose valve or dump valve.
Component B (Catalyst) Valve (if present)
This field only appears if the system includes a color change module. Enter the catalyst valve number (1 to 4).

Recipe Setup Screen 4
FIG. 41. Recipe Setup Screen 3
FIG. 42. Recipe Setup Screen 4
This screen appears only if Flush and Fill Input is set to “Recipe” in Option Screen 1, page 32.
This screen appears only if Flush and Fill Input is set to “Recipe” in Option Screen 1, page 32.
If Number of Guns is set to “2” in Configure Screen 4, page 30, a Gun 2 column will appear in this screen.
Select “Air,” “Solvent,” or “3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30).
Enter the first purge time (0 to 999 seconds).
Select “Air/Solvent” or “Air/3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30). This refers to the process of mix- ing air and solvent (or air and 3rd flush fluid) together during the flush cycle, to help clean the lines and reduce solvent usage.
Enter the total chop time (0 to 999 seconds).
Enter the final purge time (0 to 999 seconds).
Mixed Material Fill Time
Enter the mixed material fill time (0 to 999 seconds). It refers to the amount of time that is required to load mixed material from the dose valves to the applica- tor/gun.
Select “Air,” “Solvent,” or “3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30.)
Enter the air chop time (0.0 to 99.9 seconds).
Solvent Chop Time/3rd Flush Valve Chop Time
Enter the solvent or 3rd flush valve chop time (0.0 to 99.9 seconds).

Recipe Setup Screen 6
FIG. 43. Recipe Setup Screen 5
FIG. 44. Recipe Setup Screen 6
This screen appears only if K-factor Input is set to “Rec- ipe” in Option Screen 1, page 32.
This screen appears only if Flow Rate Monitor is set to “On” in Option Screen 2 on page 33.
Enter the k-factor (cc/pulse) for flow meter A. This is the amount of material that passes through the flow meter per pulse (electrical pulse signal).
Select the desired flow rate monitoring (Off, Warning, or Alarm).
Enter the low flow rate limit (1 to 3999 cc/min).
Enter the k-factor (cc/pulse) for flow meter B.
Enter the high flow rate limit (1 to 3999 cc/min).
This field only appears if Solvent Monitor in Configure Screen 5, page 31, is set to “Meter.” Enter the k-factor (cc/pulse) for the solvent flow meter.

FIG. 45. Recipe Screen 7
This screen appears only if Flush and Fill Input is set to “Recipe” in Option Screen 1, page 32 and Special Out- puts is set to 1, 2, 3, 4, or “3 + GFB on #4” in Configure Screen 5, page 31. The I/O board has four programma- ble outputs.
Delay time at the start of the purge cycle before the Spe- cial Output turns on.
Duration for the Special Output to be active during the purge cycle.
Delay time at the start of the fill cycle before the Special Output turns on.
Duration for the Special Output to be active during the fill cycle.

Enter the air chop time (0.0 to 99.9 seconds).
Solvent Chop Time/3rd Flush Valve Chop Time
Enter the solvent or 3rd flush valve chop time (0.0 to 99.9 seconds).
FIG. 47. Recipe 0 Screen 2
If Number of Guns is set to “2” in Configure Screen 4, page 30, a Gun 2 column will appear in this screen.
This field only appears if the system includes a color change module. It refers to the amount of time required to flush the lines from the color or catalyst module to the dose valve or dump valve. Enter the purge time (0 to 999 seconds).
FIG. 46. Recipe 0 Screen 1
Enter the first purge time (0 to 999 seconds).
Select “Air,” “Solvent,” or “3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30).
Enter the total chop time (0 to 999 seconds).
Select “Air/Solvent” or “Air/3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30). This refers to the process of mix- ing air and solvent (or air and 3rd flush fluid) together during the flush cycle, to help clean the lines and reduce solvent usage.
Enter the final purge time (0 to 999 seconds).
Select “Air,” “Solvent,” or “3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30.)

Recipe 0 Screen 4
FIG. 48. Recipe 0 Screen 3
FIG. 49. Recipe 0 Screen 4
This screen only appears if Solvent Monitor is set to “Meter” in Configure Screen 5, page 31 and Flush Vol- ume Check is set to “On” in Option Screen 1, page 32 or 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30.
This screen appears only if Flush and Fill Input is set to “Recipe” in Option Screen 1, page 32 and Special Out- puts is set to 1, 2, 3, 4, or “3 + GFB on #4” in Configure Screen 5, page 31. The I/O board has four programma- ble outputs.
Minimum Flush Volume This field only appears if Flush Volume Check is set to “On” in Option Screen 1 on page 32. Enter the mini- mum flush volume (0 to 9999 cc).
Exiting Fill Source This field only appears if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30. Select “Off,” “Air,” “Solvent,” or “3rd Valve.”
Delay time at the start of the purge cycle before the Spe- cial Output turns on.
Duration for the Special Output to be active during the purge cycle.
Delay time at the start of the fill cycle before the Special Output turns on.
Duration for the Special Output to be active during the fill cycle.

FIG. 50. Calibration Screen
Use this screen to calibrate a meter. Set to “A Meter,” “B Meter,” or “Solvent Meter” (available if Solvent Monitor in Configure Screen 5, page 31, is set to “Meter”).
See Meter Calibration, page 65, for when and how to calibrate a meter.
Setup Mode

Operation Modes
General Operating Cycle, Sequential Dosing
System mixes and dispenses material.
Stops the system.
Purges the system, using air and solvent.
a. Dose Valve A (DVA) opens, and fluid flows into the integrator.
Components A and B dispense sequentially in the nec- essary volumes to attain the mix ratio.
b. Flow Meter A (MA) monitors the fluid volume dispensed and sends electrical pulses to the ProMix 2KS controller. The controller monitors these pulses and signals.
In typical operation (ratios 1:1 and above), component A dispenses constantly. Component B dispenses intermit- tently in the necessary volume to attain the mix ratio.
c. When the target volume dispenses, Dose Valve A closes.
The process when the system automatically flushes out the old color and loads a new color.
d. Dose Valve B (DVB) opens, and fluid flows into the integrator and is aligned proportionately with component A.
e. Flow Meter B (MB) monitors the fluid volume dispensed and sends electrical pulses to the ProMix 2KS controller.
The Solvent Push feature enables the user to save some mixed material by pushing it out to the gun with solvent. The feature requires an accessory solvent meter. See page 63 for complete information.
f. When the target volume is dispensed, Dose Valve B closes.
The Mix Fill Push feature enables the user to prevent potlife expiration of material by mixing and flowing new material through the Gun Flush Box. See page 64 for complete information.
System Operation

pressing the Standby key or shutting off the
main power switch.
Ratio = 2.0:1 Dose 1 Dose 2 Dose 3
B = 1
DVA
FI
MB DVB
MS
MA
RVB
AT
APV
RVA
SVA SVB
SM
SPV
Key: MA Component A Meter DVA Component A Dose Valve RVA Component A Sampling Valve SVA Component A Shutoff Valve MB Component B Meter DVB Component B Dose Valve RVB Component B Sampling Valve
SVB Component B Shutoff Valve MS Solvent Meter (accessory) SPV Solvent Purge Valve APV Air Purge Valve SM Static Mixer FI Fluid Integrator AT Air Purge Valve Air Supply Tube
FIG. 51. Wall Mount Fluid Station, Sequential Dosing
System Operation · TI12556b

Dynamic Dosing System Parameters
Dynamic Dosing provides on-demand proportioning, eliminating the need for an integrator and therefore min- imizing undesired material contact. This feature is espe- cially useful with shear-sensitive and waterborne materials.
The following parameters affect dynamic dosing perfor- mance:
A restrictor injects component B into a continuous stream of component A. The software controls the dura- tion and frequency of each injection. See FIG. 52 for a schematic diagram of the process.
Component A (continuous flow) Proportioned Material
Component B (pulsed injection)
FIG. 52. Schematic Diagram of Dynamic Dosing Operation
System Operation · To Static · Mixer

Install the 15U955 Injection Kit in the fluid manifold as explained in the ProMix 2KS Installation manual. Use the charts provided in that manual to select an appropri- ate restrictor size based on the desired flow and mix ratio.
the Set Up Home screen. Select “System Configu- ration” to access the configuration screens. FIG. 53.
FIG. 53. Set Up Home Screen
FIG. 55. Configure Screen 4, dynamic dosing setup mode enabled
FIG. 54. Configure Screen 4, dynamic dosing selected
System Operation

If component B pressure is too high, it will push the com- ponent A stream aside during B injection. The valve will not open long enough, causing a High Ratio alarm.
B Pressure Too Low
If component B pressure is too low, it will not be injected in sufficient volume. The valve will stay open too long, causing a Low Ratio alarm.
Selecting the correct component B restrictor size and balancing the A/B pressures will keep the system in the proper pressure range, resulting in a consistent mix ratio.
A Pressure B Pressure
FIG. 57. A/B Control Range with Properly Sized Restrictor
FIG. 57 shows the A to B pressure balance, read at the proportioner inlet. It is recommended that the compo- nent B pressure be 5-15% higher than the component A pressure to keep the system in the control range, hold the proper mix ratio, and obtain properly mixed material. If pressures are not balanced (“B Pressure Too High” or “B Pressure Too Low”), it may not be possible to hold the desired mix ratio. The system will generate an off ratio alarm and stop operation.
B Pressure Too Low
A Pressure B Pressure
In dynamic dosing, component A dose valve is con- stantly on. Component B dose valve will cycle on and off; one cycle every 0.5 – 1.0 seconds indicates proper balance.
FIG. 58. A/B Control Range with Too Large a Restrictor
Monitor system performance by watching the EasyKey display for warning messages which provide information on system performance, and adjust pressures accord- ingly. See Table 6 on page 51.

FIG. 56. B Pressure Too Low, displayed on EasyKey

Table 6: Dynamic Dosing Troubleshooting Guide (for complete system troubleshooting, see Table 11 beginning on page 81)
To open dose or purge valves, turn hex nut (E) counter- clockwise. To close, turn clockwise. See Table 7 and FIG. 59.

FIG. 59. Valve Adjustment
Dose (FIG. 59)
Hex nut (E) 1-1/4 turns out from fully closed
Limits maximum fluid flow rate into integrator and minimizes valve response time.
Purge (FIG. 59)
Hex nut (E) 1-1/4 turns out from fully closed
Limits maximum fluid flow rate into integrator and minimizes valve response time.
Shutoff (SVA and SVB, FIG. 67)
Fully open during Run/Mix operation
Closes component A and B ports to integrator during ratio check or meter calibration. Open ports during Run/Mix operation.
Sampling (RVA and RVB, FIG. 67)
Fully closed during Run/Mix operation
Open to dispense component A and B while calibrating meters. Do not open sampling valves unless fluid shutoff valves are closed.
System Operation · TI11581a · Valve Setting Function

It is not recommended to run without an air flow switch. If a switch fails, replace it as soon as possible.
The air flow switch (AFS) detects air flow to the gun and signals the ProMix controller when the gun is triggered. The AFS functions with the flow meters to ensure that system components are functioning correctly.
It is not recommended to use an airless gun with the ProMix 2KS. Two issues can arise from operating with- out an air flow switch:
For example, if a flow meter fails or clogs, pure resin or catalyst could spray indefinitely if the ProMix does not detect the condition and intervene, which is why the AFS is so important.
If the ProMix detects through the AFS signal that the gun is triggered, yet there is no fluid flow through the meter, a Dose Time Alarm (E-7 or E-8) occurs after 40 seconds and the system shuts down.

AFS
This warning occurs if the ProMix is set to Mix , and 2 minutes have elapsed since the system received a flow meter pulse.
In applications using the AFS, triggering the gun clears the warning and you can start spraying again.
Without the AFS, triggering the gun does not clear the alarm. To start spraying again, you must press Standby
, then Mix , then trigger the gun.
System Operation · TI13350a

Graco logo, software revision, and “Establishing
Communication” will display, followed by Status screen. See page 20. At power up the system defaults to Recipe 61,
which is not a valid recipe number. Initiate a color change to Recipe 0 or a valid recipe num- ber (1-60). In bottom left corner, the system status dis-
Verify all grounding connections were made. See the Installation manual.
plays, which can be Standby, Mix, Purge, or an alarm notification
All connections tight and correct
Verify all electrical, fluid, air, and system connec- tions are tight and installed according to the Installation manual.
Check air purge valve tubing
Check the air purge valve supply tube daily for any visible solvent accumulation. Notify your supervisor if solvent is present.
Fluid supply containers filled
Check component A and B and solvent supply containers.
Mix manifold valves set
Check that mix manifold valves are set correctly. Start with the settings recommended in Mix Mani- fold Valve Settings, page 51, then adjust as needed.
FIG. 62. Status Screen
Fluid supply valves open and pressure set
Component A and B fluid supply pressures should be equal unless one component is more viscous and requires a higher pressure setting.
Standby LED should be lit.
75-100 psi inlet air supply (0.5-0.7 MPa, 5.2-7 bar)

mode.
FIG. 61. Power Switch

Watch the fluid flow rate displayed on the Status screen while the gun is fully open. Verify that the flow rate of components A and B are within 10% of each other.
If the fluid flow rate is too low: increase air pres- sure to component A and B fluid supplies or increase the regulated fluid pressure.
If the fluid flow rate is too high: reduce the air pressure, close the fluid manifold dose valves fur- ther, or adjust the fluid pressure regulator.
and close the lid. Press the Purge key on the
Booth Control. The purge sequence automatically starts.
If the gun flush box is not used, trig- ger the gun into a grounded metal pail until the purge sequence is com- plete.
NOTE: Do not allow a fluid supply tank to run empty. It is possible for air flow in the supply line to turn gear meters in the same manner as fluid. This can lead to the proportioning of fluid and air that meets the ratio and tol- erance settings of the equipment. This can further result in spraying uncatalyzed or poorly catalyzed material.
When done purging, the Booth Control automati- cally switches to Standby mode.
The fluid flow rate shown on the EasyKey Status screen is for either component A or B, depending on which dose valve is open. The fluid supply lines on the screen highlight to show which dose valve is open.
FIG. 63. Status Screen Flow Rate Display
System Operation

Pressure Relief Procedure
Relieve pressure when you stop spraying, before changing spray tips, and before cleaning, checking, or servicing equipment.
FIG. 64. Power Switch
System Operation · TI12657a

Systems with Color/Catalyst Change and Dump Valves
System Operation


J1
CAN
J13
CAN
J12
J3
Dose A Dose B
GFB 2
GFB 1
J14 J15 J8
GFB 1
GFB 2
3rd Purge Valve Solenoid
Purge Valve B Solenoid Purge Valve A Solenoid Dose Valve B
FIG. 65. Fluid Solenoids


FI
MB DVB

Dose Valve RVA Component A
Sampling Valve SVA Component A
Shutoff Valve MB Component B Meter DVB Component B
Dose Valve RVB Component B
Sampling Valve SVB Component B
Shutoff Valve MS Solvent Meter SPV Solvent Purge Valve APV Air Purge Valve SM Static Mixer FI Fluid Integrator AT Air Purge Valve Air Supply Tube
APV
RVA
SVA SVB
SM
SPV
FIG. 67. Wall Mount Fluid Station

If using an electrostatic gun shut off the electrostatics before flushing the gun.
Read Warnings, page 7. Follow the Grounding instructions in your system Installation manual.
To avoid splashing fluid in the eyes, wear eye protec- tion.
There are 4 purging procedures in this manual:
and close the lid. Press the Purge key on the
Booth Control. The purge sequence automatically starts.
Use the criteria listed in each procedure to determine which procedure to use.
If the gun flush box is not used, trig- ger the gun into a grounded metal pail until the purge sequence is com- plete.
There are times when you only want to purge the fluid manifold, such as:
When done purging, the Booth Control automati- cally switches to Standby mode.
Solvent purges the component B (catalyst, right) side of the mix manifold and the inner tube of the integrator. Air purges the component A (resin, left) side and the outer tube of the integrator.
Trigger the gun to relieve pressure. Engage trigger lock.
Trigger the gun to relieve pressure.
If you are using a high pressure gun, engage the trig- ger lock. Remove spray tip and clean tip separately.
System Operation

Purging Fluid Supply System
To setup Recipe 0, go to Advanced Setup. Select the Recipe tab and change the Recipe to 0. The Recipe 0 Setup Screen appears. Set the chop times from 0-999 seconds in increments of 1 second.
* Some steps are not necessary for initial flushing, as no material has been loaded into the system yet.
Trigger the gun to relieve pressure.
Trigger the gun to relieve pressure.
If you are using a high pressure gun, engage the trig- ger lock. Remove spray tip and clean tip separately.
If you are using a high pressure gun, engage the trig- ger lock. Remove spray tip and clean tip separately.
If using an electrostatic gun, shut off the electrostatics before flushing the gun.
If using an electrostatic gun shut off the electrostatics before flushing the gun.
repeat Recipe 0 by pressing Enter .
System Operation

Purge component B side. Press the manual override on the Dose Valve B solenoid valve and trigger the gun into a grounded metal pail until clean solvent flows from the gun.
Repeat to thoroughly clean the fluid integrator.
Select Recipe 0 and press Enter to purge the component A side. The color change LED blinks while Recipe 0 runs and turns solid after purge sequence is complete.
Purge component B side. Press the manual override on the Dose Valve B solenoid valve and trigger the gun into a grounded metal pail until clean solvent flows from the gun.
Repeat to thoroughly clean the fluid integrator.
Select Recipe 0 and press Enter to purge the component A side and the component B side. The color change LED blinks while Recipe 0 runs and turns solid after purge sequence is complete.
Repeat to thoroughly clean the fluid integrator.
System Operation

Follow this procedure after meter calibration.
access the Advanced Setup screens.
tion screen. Press the Down Arrow key and
select Purge from the menu. Press the Enter key.
Dose A, solvent purge valve (B side), and color change solvent valves (if used) will open.
FIG. 68. Calibration Screen
System Operation

The Solvent Push feature enables the user to save some mixed material by pushing it out to the gun with solvent. The quantity saved is 50% of the potlife volume entered in Advanced Setup Screen 1 on page 35. If there are 2 guns, the smaller potlife volume is used.
close the Dose Valves (DVA, DVB) and open the Solvent Purge Valve (SPV).
Solvent Push requires an accessory solvent meter (MS). Order Graco Part No. 16D329 S3000 Solvent Meter Kit. See manual 308778.
Standby key. The Solvent Purge Valve (SPV) or
3rd purge valve will close. To re-enter Solvent Push,
press the Mix key.
mode.
Key: DVA Component A Dose Valve DVB Component B Dose Valve MS Solvent Meter (required) SPV Solvent Purge Valve APV Air Purge Valve SMC Solvent Meter Cable SS Solvent Supply Line
SMC
SS
FIG. 69. Solvent Push Setup

The Mix Fill Push feature enables the user to prevent potlife expiration of material by mixing and flowing new material through the Gun Flush Box.
Mix Fill Push requires an accessory Gun Flush Box for each gun that will use this feature. Order Graco Part No. 15V826 Fun Flush Box Kit. See manual 312784.
Mix Fill Push requires a Gun Flush Box for the gun. If two guns are used, each requires a Fun Flush Box for this feature to operate. The second Gun Flush Box must be configured as a Special Output. See Configure Screen 5 on page 31.
To enable Mix Fill Push, select “Mix Fill Push” in the Auto Dump field. See Option Screen 2, page 33.

FIG. 70. Mix Fill Push Timing Chart
System Operation

To avoid splashing fluid in the eyes, wear eye protec- tion. The fluid shutoff valves and ratio check valves are retained by mechanical stops that prevent accidental removal of the valve stem while the manifold is pres- surized. If you cannot turn the valve stems manually, relieve the system pressure, then disassemble and clean the valve to remove the resistance.
setup screens.
Enter key to select.
Calibrate the meter:
tion Screen. Press the Enter key to select either A Meter, B Meter, or Solvent. Press the Down
Arrow key and select Start from the menu. Start only one at a time.
Meter Calibration

a. To avoid splashing, slowly open sampling valves.
b. For more accurate calibration, adjust the valve to dispense at a flow rate similar to your produc- tion spray flow rate.
c. Dispense a minimum of 250 cc; make sure enough material is dispensed to accurately read the volume with your beaker. The A and B vol- umes do not have to be equal or at any particu- lar ratio.
d. Close sampling valve tightly.
a. Go to Mix mode.
b. Trigger the gun into a grounded metal pail until mixed material flows from the gun nozzle.
c. To begin operation, see Start Up, page 53.
vent Volume field, and press the Enter key.
If the value was substantially different, repeat the calibration process.
Screen menu and press the Enter key.
Meter Calibration

Color Change Procedures
Color Change Sequences
FIG. 71 through FIG. 80 illustrate various color change sequences. See Table 9 to determine which figure to reference, based on the recipe change and system con- figuration. The time sequences are detailed in the fol- lowing paragraphs.
color. Press Enter to begin the color change sequence.
mode at the previous color.
Color Change

First Purge
Select the First Purge Source (air, solvent, or 3rd valve) and First Purge Time. For most applications, air is selected.
The system purges the old material from the dose valves to the gun, using only the selected purge media (usually air). The selected purge valve opens during the First Purge Time and closes when the time expires.
Chop Cycle
Select the Chop Type (air/solvent or air/3rd valve) and Chop Times.
The air purge valve opens only during the air chop cycle, and the solvent (or 3rd valve) opens only during the solvent chop cycle. The number of chop cycles is determined by dividing the Total Chop Time by the sum of the Air and Solvent Chop Times.
Final Purge
Select the Final Purge Source (air, solvent, or 3rd valve) and Final Purge Time. For most applications, solvent is selected.
The system fills the line with solvent from the dose valves to the gun, using only the selected purge media (usually solvent). The selected purge valve opens during the Final Purge Time and closes when the time expires.
Fill
This sequence fills the line from the dose valves to the gun, and is also referred to as the mixed material fill. The system begins mixing components A and B until the Fill Time expires.
Color Change

Type Dump A Exiting Fill Refer to Fig.
X Y Change Yes NA FIG. 71
X Y Change No NA FIG. 72
0 Y Fill Yes Yes FIG. 73
0 Y Fill Yes No FIG. 74
0 Y Fill No Yes FIG. 75
0 Y Fill No No FIG. 76
X 0 Purge Yes NA FIG. 77
X 0 Purge No NA FIG. 78
0 0 Purge Yes NA FIG. 79
0 0 Purge No NA FIG. 80

3 + GFB on #4 2KS X to Y K15
Fill Active Output End of Color Change ->
Special Output #4
Solvent A If a component is not changing, that time segment is skipped
Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time
First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Color Change Stack Flush Sequence Color Change Stack Components
Mixed Fill Time using Sequential Dosing
Mixed Fill Time using Dynamic Dosing
Dump B Flush out old catalyst and fill with new catalyst
Dose Valve and Integrator Flush Sequence Purge Operation Details
Special Output #3
2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2
Dump A Flush out old color and fill with new color
Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2
3rd Purge Valve on A If Chop Type is "Air/3rd Purge"
Purge B (Solvent) If Chop Type is "Air/Solvent"
Special Output #2
Purge A (Air) Fixed for Purge A (Air)
This happens on the same time scale as the Dose Valve and Integrator Flush Sequence
Special Outputs
Dose Valve and Integrator Flush Purge and Chop Operations by Time
Special Output #1
A Fill A Purge Color Change Stack Purge and Fill Operations by Time
Dose Valve and Integrator Mix Fill Operations by Time
Discrete I/O Signals by Time
Final Purge First Purge Total Chop
B Fill B Purge
ProMix 2KS Recipe Change Chart #1 X to Y
Dump A Enabled, 3rd Flush Valve Enabled
Stack Valves A1 to A2, B1 to B2
Color Change Input
Purge from X, Fill from Y -->
Purge from X -->
Fill from Y -->
Separate Gun 1 and Gun 2
Separate Gun 1 and Gun 2
If No Gun Flush Boxes
1 Gun Gun Flush Box Output 1
2 Guns Gun Flush Box Output 1
Gun Trigger(s) by Operator
Gun Flush Box Output 2
Gun Flush Box Output 2

3 + GFB on #4 2KS X to Y K13
Fill Active Output End of Color Change ->
Special Output #4
Solvent A If a component is not changing, that time segment is skipped
Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time
First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Mixed Fill Time using Sequential Dosing
Mixed Fill Time using Dynamic Dosing
Color Change Stack Flush Sequence Color Change Stack Components A Fill A Purge B Fill B Purge
Special Output #3
Dump B Flush out old catalyst and fill with new catalyst
Dose Valve and Integrator Flush Sequence Purge Operation Details
2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2
Dump A Flush out old color and fill with new color
Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2
3rd Purge Valve on A If Chop Type is "Air/3rd Purge"
Purge B (Solvent) If Chop Type is "Air/Solvent"
This happens on the same time scale as the Dose Valve and Integrator Flush Sequence
Special Output #2
Purge A (Air) Fixed for Purge A (Air)
Special Outputs
Dose Valve and Integrator Flush Purge and Chop Operations by Time
Special Output #1
Color Change Stack Purge and Fill Operations by Time
Dose Valve and Integrator Mix Fill Operations by Time
Final Purge 2 s B
Discrete I/O Signals by Time
Dose A
ProMix 2KS Recipe Change Chart #2 X to Y
No Dump A, 3rd Flush Valve Enabled
Stack Valves A1 to A2, B1 to B2
Total Chop First Purge Waiting
Color Change Input
Purge from X, Fill from Y -->
Purge from X -->
Fill from Y -->
Separate Gun 1 and Gun 2
Separate Gun 1 and Gun 2
If No Gun Flush Boxes
Gun Trigger(s) by Operator
1 Gun Gun Flush Box Output 1
2 Guns Gun Flush Box Output 1
Gun Flush Box Output 2
Gun Flush Box Output 2

3 + GFB on #4 2KS 0 to Y K15
Fill Active Output End of Color Change ->
Special Output #4
Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time
Color Change Stack Fill Sequence Color Change Stack Components
First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Mixed Fill Time using Sequential Dosing
Mixed Fill Time using Dynamic Dosing
Dose Valve and Integrator Flush Sequence Purge Operation Details
Special Output #3
2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2
Dump B Push out solvent and fill with new catalyst
Dump A Push out solvent and fill with new color
Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2
Solvent A Only active components are filled
3rd Purge Valve on A If Chop Type is "Air/3rd Purge"
Purge B (Solvent) If Chop Type is "Air/Solvent"
This happens on the same time scale as the Dose Valve and Integrator Flush Sequence
Special Output #2
Purge A (Air) Fixed for Purge A (Air)
Dose Valve and Integrator Flush Purge and Chop Operations by Time
Special Outputs
Color Change Stack Purge and Fill Operations by Time
Special Output #1
Dose Valve and Integrator Mix Fill Operations by Time
Discrete I/O Signals by Time
Dump A Enabled, 3rd Flush Valve Enabled
ProMix 2KS Recipe Fill Chart #3 0 to Y
B Fill A Fill
Stack Valves A1, B1
Exit. Fill Waiting
Color Change Input
No Purge, Fill from Y -->
Fill from Y -->
Separate Gun 1 and Gun 2
Separate Gun 1 and Gun 2
If No Gun Flush Boxes
Gun Trigger(s) by Operator
1 Gun Gun Flush Box Output 1
2 Guns Gun Flush Box Output 1
Gun Flush Box Output 2
Gun Flush Box Output 2

3 + GFB on #4 2KS 0 to Y K14
Fill Active Output End of Color Change ->
Special Output #4
Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time
First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Mixed Fill Time using Sequential Dosing
Mixed Fill Time using Dynamic Dosing
Color Change Stack Flush Sequence Color Change Stack Components A Fill B Fill Color Change Stack Purge and Fill Operations by Time
Special Output #3
Dose Valve and Integrator Flush Sequence Purge Operation Details
2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2
Dump B Push out solvent and fill with new catalyst
Dump A Push out solvent and fill with new color
Solvent A Only active components are filled
Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2
3rd Purge Valve on A If Chop Type is "Air/3rd Purge"
Purge B (Solvent) If Chop Type is "Air/Solvent"
This happens on the same time scale as the Dose Valve and Integrator Flush Sequence
Special Output #2
Purge A (Air) Fixed for Purge A (Air)
Special Outputs
Dose Valve and Integrator Flush Purge and Chop Operations by Time
Special Output #1
Dose Valve and Integrator Mix Fill Operations by Time
Discrete I/O Signals by Time
Dump A Enabled, 3rd Flush Valve Enabled
ProMix 2KS Recipe Fill Chart #4 0 to Y
Stack Valves A1, B1
Color Change Input
No Purge, Fill from Y -->
Fill from Y -->
Separate Gun 1 and Gun 2
Separate Gun 1 and Gun 2
If No Gun Flush Boxes
Gun Trigger(s) by Operator
1 Gun Gun Flush Box Output 1
2 Guns Gun Flush Box Output 1
Gun Flush Box Output 2
Gun Flush Box Output 2

3 + GFB on #4 2KS 0 to Y K13
Fill Active Output End of Color Change ->
Special Output #4
Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time
Color Change Stack Fill Sequence Color Change Stack Components
Mixed Fill Time using Sequential Dosing
Mixed Fill Time using Dynamic Dosing
First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Dose Valve and Integrator Flush Sequence Purge Operation Details
Special Output #3
2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2
Dump B Push out solvent and fill with new catalyst
Dump A Push out solvent and fill with new color
Solvent A Only active components are filled
3rd Purge Valve on A If Chop Type is "Air/3rd Purge"
Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2
Purge B (Solvent) If Chop Type is "Air/Solvent"
Special Output #2
Purge A (Air) Fixed for Purge A (Air)
This happens on the same time scale as the Dose Valve and Integrator Flush Sequence
Special Outputs
Special Output #1
Dose Valve and Integrator Flush Purge and Chop Operations by Time
Color Change Stack Purge and Fill Operations by Time
Dose Valve and Integrator Mix Fill Operations by Time
Discrete I/O Signals by Time
Dose A
ProMix 2KS Recipe Fill Chart #5 0 to Y
No Dump A, 3rd Flush Valve Enabled
Waiting A Fill B Fill
Stack Valves A1, B1
Exit. Fill Waiting
Color Change Input
No Purge, Fill from Y -->
Fill from Y -->
Separate Gun 1 and Gun 2
Separate Gun 1 and Gun 2
If No Gun Flush Boxes
Gun Trigger(s) by Operator
1 Gun Gun Flush Box Output 1
2 Guns Gun Flush Box Output 1
Gun Flush Box Output 2
Gun Flush Box Output 2

3 + GFB on #4 2KS 0 to X K12
Fill Active Output End of Color Change ->
Special Output #4
Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time
Color Change Stack Flush Sequence Color Change Stack Components
Mixed Fill Time using Sequential Dosing
Mixed Fill Time using Dynamic Dosing
First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Dose Valve and Integrator Flush Sequence Purge Operation Details
Special Output #3
2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2
Dump B Push out solvent and fill with new catalyst
Dump A Push out solvent and fill with new color
GFB 1 Only Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2
Solvent A Only active components are filled
3rd Purge Valve on A If Chop Type is "Air/3rd Purge"
Purge B (Solvent) If Chop Type is "Air/Solvent"
This happens on the same time scale as the Dose Valve and Integrator Flush Sequence
Special Output #2
Purge A (Air) Fixed for Purge A (Air)
Dose Valve and Integrator Flush Purge and Chop Operations by Time
Special Outputs
Color Change Stack Purge and Fill Operations by Time
Dose Valve and Integrator Mix Fill Operations by Time
Special Output #1
Discrete I/O Signals by Time
ProMix 2KS Recipe Fill Chart #6 0 to Y
No Dump A, 3rd Flush Valve Enabled
Dose A
Stack Valves A1, B1
A Fill B Fill
Color Change Input
No Purge, Fill from Y -->
Fill from Y -->
Separate Gun 1 and Gun 2
Separate Gun 1 and Gun 2
If No Gun Flush Boxes
Gun Trigger(s) by Operator
2 Guns Gun Flush Box Output 1
1 Gun Gun Flush Box Output 1
Gun Flush Box Output 2
Gun Flush Box Output 2

3 + GFB on #4 2KS X to 0 K15
Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time
Color Change Stack Flush Sequence Color Change Stack Components A Purge B Purge
Mixed Fill Time using Sequential Dosing
Mixed Fill Time using Dynamic Dosing
First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Dose Valve and Integrator Flush Sequence Purge Operation Details
Solvent A Every recipe 0 entry will flush all components
2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2
Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2
3rd Purge Valve on A If Chop Type is "Air/3rd Purge"
Purge B (Solvent) If Chop Type is "Air/Solvent"
This happens on the same time scale as the Dose Valve and Integrator Flush Sequence
Dump B Flush out old catalyst
Purge A (Air) Fixed for Purge A (Air)
Dump A Flush out old color
Dose Valve and Integrator Flush Purge and Chop Operations by Time
Color Change Stack Purge and Fill Operations by Time
Dose Valve and Integrator Mix Fill Operations by Time
Discrete I/O Signals by Time
Purge Active Output End of Color Change ->
ProMix 2KS Recipe Purge Chart #7 X to 0
Dump A Enabled, 3rd Flush Valve Enabled
First Purge Total Chop Final Purge
Special Output #4
This activates for Autodump operations only
Special Output #3
Color Change Input
Special Output #2
Special Outputs
Special Output #1
Purge from 0, No Fill -->
Purge from 0 -->
Separate Gun 1 and Gun 2
Separate Gun 1 and Gun 2
If No Gun Flush Boxes
Gun Trigger(s) by Operator
1 Gun Gun Flush Box Output 1
Gun Flush Box Output 2
2 Guns Gun Flush Box Output 1
Gun Flush Box Output 2

3 + GFB on #4 2KS X to 0 K13
Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time
Mixed Fill Time using Sequential Dosing
Color Change Stack Flush Sequence Color Change Stack Components Waiting
First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Mixed Fill Time using Dynamic Dosing
Dose Valve and Integrator Flush Sequence Purge Operation Details
Solvent A Every recipe 0 entry will flush all components
2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2
Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2
3rd Purge Valve on A If Chop Type is "Air/3rd Purge"
Purge B (Solvent) If Chop Type is "Air/Solvent"
This happens on the same time scale as the Dose Valve and Integrator Flush Sequence
Dump B Flush out old catalyst
Purge A (Air) Fixed for Purge A (Air)
Dump A Flush out old color
Dose Valve and Integrator Flush Purge and Chop Operations by Time
Color Change Stack Purge and Fill Operations by Time
Dose Valve and Integrator Mix Fill Operations by Time
Discrete I/O Signals by Time
Purge Active Output End of Color Change ->
Waiting First Purge Total Chop 2 s B Final Purge
ProMix 2KS Recipe Purge Chart #8 X to 0
No Dump A, 3rd Flush Valve Enabled
Dose A
This activates for Autodump operations only
Special Output #4
B Purge A Purge
Special Output #3
Color Change Input
Special Output #2
Special Outputs
Special Output #1
Purge from X, Fill from Y -->
Purge from 0 -->
Separate Gun 1 and Gun 2
Separate Gun 1 and Gun 2
If No Gun Flush Boxes
2 Guns Gun Flush Box Output 1
Gun Trigger(s) by Operator
1 Gun Gun Flush Box Output 1
Gun Flush Box Output 2
Gun Flush Box Output 2

3 + GFB on #4 2KS 0 to 0 K3
Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time
Color Change Stack Flush Sequence Color Change Stack Components
Mixed Fill Time using Sequential Dosing
Mixed Fill Time using Dynamic Dosing
First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Dose Valve and Integrator Flush Sequence Purge Operation Details
Solvent A Every recipe 0 entry will flush all components
2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2
Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2
3rd Purge Valve on A If Chop Type is "Air/3rd Purge"
Dose Valve and Integrator Flush Purge and Chop Operations by Time - From Recipe 0
Purge B (Solvent) If Chop Type is "Air/Solvent"
This happens on the same time scale as the Dose Valve and Integrator Flush Sequence
Color Change Stack Purge and Fill Operations by Time - From Recipe 0
Purge A (Air) Fixed for Purge A (Air)
Dump B Flush out old catalyst
Dump A Flush out old color
Dose Valve and Integrator Mix Fill Operations by Time
Discrete I/O Signals by Time
Purge Active Output End of Color Change ->
Dump A Enabled, 3rd Flush Valve Enabled
Final Purge First Purge
ProMix 2KS Recipe Purge Chart #9 0 to 0
Exit. Fill Total Chop 2 s B
Special Output #4
Waiting A Purge B Purge
Special Output #3
Color Change Input
Special Output #2
Special Outputs
Special Output #1
Purge from 0, No Fill -->
Purge from 0 -->
Separate Gun 1 and Gun 2
Separate Gun 1 and Gun 2
If No Gun Flush Boxes
Gun Trigger(s) by Operator
2 Guns Gun Flush Box Output 1
1 Gun Gun Flush Box Output 1
Gun Flush Box Output 2
Gun Flush Box Output 2

3 + GFB on #4 2KS 0 to 0 K1
Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time
Mixed Fill Time using Sequential Dosing
Color Change Stack Flush Sequence Color Change Stack Components Waiting
First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A
Mixed Fill Time using Dynamic Dosing
Dose Valve and Integrator Flush Sequence Purge Operation Details
Solvent A Every recipe 0 entry will flush all components
2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2
Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2
3rd Purge Valve on A If Chop Type is "Air/3rd Purge"
Purge B (Solvent) If Chop Type is "Air/Solvent"
Dose Valve and Integrator Flush Purge and Chop Operations by Time - From Recipe 0
Purge A (Air) Fixed for Purge A (Air)
This happens on the same time scale as the Dose Valve and Integrator Flush Sequence
Dump B Flush out old catalyst
Color Change Stack Purge and Fill Operations by Time - From Recipe 0
Dump A Flush out old color
Dose Valve and Integrator Mix Fill Operations by Time
Purge Active Output End of Color Change ->
Final Purge 2 s B Total Chop First Purge Exit. Fill Waiting
Discrete I/O Signals by Time
ProMix 2KS Recipe Purge Chart #10 0 to 0
No Dump A, 3rd Flush Valve Enabled
Waiting B Purge A Purge
Dose A
Special Output #4
Special Output #3
Color Change Input
Special Output #2
Special Outputs
Special Output #1
Purge from 0, No Fill -->
Purge from 0 -->
Separate Gun 1 and Gun 2
Separate Gun 1 and Gun 2
If No Gun Flush Boxes
Gun Trigger(s) by Operator
2 Guns Gun Flush Box Output 1
1 Gun Gun Flush Box Output 1
Gun Flush Box Output 2
Gun Flush Box Output 2

System alarms alert you of a problem and help prevent off-ratio spraying. If an alarm occurs, operation stops and the following occurs:
To reset alarms, see Table 11. Many alarms can be
cleared by simply pressing the Alarm Reset key.


E-5 Overdose A/B Dose Too Short Alarm Page 84
E-6 Overdose B/A Dose Too Short Alarm Page 84
FIG. 81. Booth Control
Table 10 lists the System Warning Codes. Warnings do not stop operation or sound an alarm. They are saved in the date/time stamped log, which can be viewed on a PC, using the ProMix 2KS Web Interface (see manual 313386).

Table 11. Alarm Troubleshooting
No power to the EasyKey. Connect power to EasyKey.
No power to Fluid Station. The intrinsically safe power cable between the EasyKey and Fluid Station is not con- nected.
Verify that the cable is correctly connected. See Installa- tion manual.
No power to Fluid Station. The fluid control board fuse is blown.
Verify condition of fuse and replace if necessary. See Repair-Parts manual.
The fiber optic cable between the EasyKey and Fluid Station is not connected.
Verify that the cable is correctly connected. See Installa- tion manual.
The fiber optic cable is cut or bent. Verify that the cable has not been cut or bent at a radius smaller than 1.6 in. (40 mm).
Dirty fiber optic cable ends. Disconnect fiber optic cable ends and clean with a lint-free cloth.
A communication cable or connector failed. Replace cable.
The potlife time has been exceeded for the mixed mate- rial. Press the Alarm Reset key to stop the audible
alarm. Purge the system with solvent, fresh mixed mate- rial, or a new color:
Alarm Troubleshooting · Cause Solution · Cause Solution

Table 11. Alarm Troubleshooting
The mix ratio is higher than the set tolerance on the previous dose cycle.
The mix ratio is higher than the set tolerance for an A to B component volume comparison.
There is too little restriction in the system. • Check that the system is fully loaded with material.
If the alarm occurs during start up, after purging, the flow rate was probably too high.
Restrict gun needle travel to slow down the initial fluid delivery rate until fluid hoses are loaded with material.
If the alarm occurred after you were spraying for some time, the pressures from the fluid supplies could be unbalanced.
Adjust component A and B fluid supply regulator pres- sures until they are about equal. If the pressures are already about equal, verify that component A and B dose valves are operating properly.
Slow actuation of the component A or B valves. This can be caused by:
Manually operate the Dispense A and B solenoid valves as instructed in the ProMix 2KS Repair-Parts manual to check operation.

Table 11. Alarm Troubleshooting
The mix ratio is lower than the set tolerance on the previous dose cycle.
The mix ratio is lower than the set tolerance for an A to B component volume comparison.
There is too much restriction in the system. • Check that the system is fully loaded with material.
If the alarm occurs during start up, after purging, the flow rate was probably too high.
Restrict gun needle travel to slow down the initial fluid delivery rate until fluid hoses are loaded with material.
If the alarm occurred after you were spraying for some time, the pressures from the fluid supplies could be unbalanced.
Adjust component A and B fluid supply regulator pres- sures until they are about equal. If the pressures are already about equal, verify that component A and B dose valves are operating properly.
Slow actuation of the component A or B valves. This can be caused by:
Manually operate the Dispense A and B solenoid valves as instructed in the ProMix 2KS Repair-Parts manual to check operation.

Table 11. Alarm Troubleshooting
E-5: the A dose overshoots and, when combined with B, is too large for the mix chamber capacity.
E-6: the B dose overshoots and forces an A side dose that, when combined with B, is too large for the mix chamber capacity.
Valve seal or needle/seat are leaking. Check FIG. 11 Totals Screen on page 23. If A and B are dosing simul- taneously (sequential dosing only), there is a leak.
Repair the valve (see valve manual 312782).
Sampling valve is leaking. Tighten or replace valve.
Flow meter fluctuations caused by pressure pulsations. Check for pressure pulsations:
Slow actuation of component A or B valves. See E-3: RATIO HIGH ALARM and E-4: RATIO LOW ALARM, pages 82-83.
Running a high mix ratio and a high flow rate. It may be necessary to restrict the flow rate through the component B dose valve by adjusting its hex nut (E). See page 51.
Alarm Troubleshooting · Cause Solution

Table 11. Alarm Troubleshooting
E-7: gun trigger input is active (AFS or Integration) and fewer than 31 A meter pulses were detected during the dose time selected.
E-8: gun trigger input is active (AFS or Integration) and fewer than 31 B meter pulses were detected during the dose time selected.
Fully trigger the gun.
System is in Mix mode and gun is only partially triggered, allowing air but no fluid to pass through gun.
Fluid flow rate is too low. Increase flow rate.
Dose time setting is too short for the current flow rate. Increase the dose time setting.
Flow meter or cable failed or flow meter clogged. To check meter sensor operation, remove meter cap to expose sensor. Pass a ferrous metal tool in front of the sensor.

If there is a meter or cable failure, you will see a large dif- ference between the amount of fluid dispensed and the flow meter volume displayed by the EasyKey. Clean or repair meter as necessary. Also see meter manual 308778.
Follow Meter Calibration procedure, page 65.
Slow actuation of component A or B valves. See E-3: RATIO HIGH ALARM and E-4: RATIO LOW ALARM, pages 82-83.
The supply pump is not turned on. Turn on the supply pump.
There is an air leak downstream from the air flow switch. Check the air lines for leaks and repair.
The air flow switch is stuck open. Clean or replace air flow switch.
System is in Mix mode with 0 volume entered for Min Material Fill Volume (see Option Screen 1, page 32), and Fuse F1 is blown.
Verify condition of fuse and replace if necessary. See Repair-Parts manual.
Alarm Troubleshooting · Cause Solution · TI12792a

Table 11. Alarm Troubleshooting
Automation has requested that the system abort all oper- ations.
Abort operations. Troubleshoot automation system.
ProMix 2KS solvent flow switch is not activated while purging.
Verify that the gun is not shut off and that the solvent flow switch is activated while purge is taking place.
Minimum flush volume is not achieved. Increase solvent supply or decrease minimum volume setting.
No meter pulses during Color/Catalyst Dump. Color change solvent supply not set up or functional. Check Color Change setup.
Alarm Troubleshooting · Cause Solution · Cause Solution

Table 11. Alarm Troubleshooting
Communication between the Color Change Module and the Fluid Station is interrupted.
Communication between the Color Change Module and the Fluid Station is interrupted. The fluid control board fuse is blown.
Verify condition of fuse and replace if necessary. See Repair-Parts manual.
Communication between the Booth Control and the Fluid Station is interrupted.
Verify that the cable is correctly connected.
Alarm Troubleshooting · Cause Solution

Table 11. Alarm Troubleshooting
Fluid system is producing too much or too little flow. Troubleshoot fluid system for restrictions, leaks, exhausted fluid supply, incorrect settings, etc. Increase or decrease flow rate, as required.
Mix input is high, but the gun has not been triggered for 2 minutes.
If not painting, clear alarm and resume operation.
If painting, shut down and inspect fluid meter and air flow switch.
The system setup parameters have been changed. No action required. See Event Log available through advanced web interface.
The power to the system has been cycled. No action required. See Event Log available through advanced web interface.
Voltage becoming too low due to weak power supply. Replace power supply. See Repair-Parts manual.
Power wires are disconnected or making intermittent contact.
Check that all wires are securely connected. Ensure that wires are not stretched too tightly.
Reset button has been pushed (S1 on EasyKey display board, S3 on Autokey).
No action required. See Event Log available through advanced web interface.
Software update is initiated on EasyKey. No action required. See Event Log available through advanced web interface.
The factory defaults have been installed on the system. No action required. See Event Log available through advanced web interface.

Table 11. Alarm Troubleshooting
The Mix and Purge digital inputs are on at the same time. Ensure that only one input is on at a time. At least 1 sec
delay is required when switching from Mix to Purge or vice versa.
Fluid Plate Reboot (FP Reboot): Occurs if the system detects a fluid plate control board reboot or power cycle not triggered from the EasyKey. The system reverts to Recipe 61, and mixed material may be in the lines.
Flush the system or perform a color change. If possible, identify the origin of the reboot or power cycle.
Autokey Lost: Occurs if the Autokey is lost or changed after having been detected. (A short term loss of the Autokey will not be registered.) Some system functions may become unavailable. For example, an automatic system will not respond to PLC or robot control.
Reinstall the Autokey, or verify that the Autokey is set properly.
Illegal Source: Occurs if a recipe outside of the range 1-60 is detected as the source data for global recipe data copies. This is possible if an invalid configuration file is sent to the EasyKey.
Verify that the source data is from a valid recipe (1-60).
2K/3K Error: Occurs if the recipe data is incompatible with the current Autokey setting (2K or 3K). This is possi- ble if the Autokey is changed or an invalid configuration file is sent to the EasyKey.
Verify that the Autokey is set properly or that the configu- ration file is valid.
Init Error: Occurs if the recipe data codes specifying the type of machine they were made on are not what is expected. For example, a 3KS machine receives a con- figuration file originally made on a 2KS machine.
Verify that the configuration file is valid.
Config Error: Occurs if a configuration file sent to the EasyKey specifies a different hardware setup than what exists. For example, the configuration file specifies 2 color change boards but only 1 is present.
Verify that the configuration file specifications and the hardware conform.
Range Error: Occurs if a valve used in a recipe is not present in the current hardware setup. For example, a recipe calls for valve 30 but the system has only 12 valves.
Verify that the recipe specifications and the hardware conform.
Level Control (LC) Error: Occurs if level control data is received by the EasyKey, and the current Autokey set- ting (2K or 3K) has changed since the level control data was originally initialized.
Verify that the Autokey is set properly.
Level Control (LC) Range Error: Occurs if level control data includes a valve range exceeding the capability of the machine.
Set level control data correctly.
Modbus (MB) Overflow: Occurs if the Modbus connec- tion to a PLC experiences data overflow.
Verify the Modbus protocol to the EasyKey.
Alarm Troubleshooting · Cause Solution

Table 11. Alarm Troubleshooting
System detects atomizing air to the gun when purge is selected.
Shut off gun air.
For systems with a gun flush box, gun is not in the box when purge is selected.
Place gun in gun flush box. Verify that gun flush box is operating properly.
For systems with auto dump on, gun is not in the box when auto dump is initiated.
Place gun in gun flush box. Verify that gun flush box is operating properly.
For systems with a gun flush box, Fuse F2 is blown. Verify condition of fuse and replace if necessary. See Repair-Parts manual.
For systems with minimum mixed material fill volume entered, the system detects that fill volume is not achieved during mixed material fill time.
Check for restrictions or leaks in the fluid supply system.
Check if the fill volume is properly configured:
For systems without color change and with minimum mixed material fill volume entered, Fuse F1 is blown.
Verify condition of fuse and replace if necessary. See Repair-Parts manual.
E-22: TANK A LOW ALARM, E-23: TANK B LOW ALARM, or E-24: TANK S LOW ALARM
The tank volume reaches the low-level threshold. The EasyKey screen will display the alarm and prompt the user to do one of the following:

Table 11. Alarm Troubleshooting
A potlife alarm is active for more than 2 minutes, the gun flush box is enabled and gun is in the gun flush box, and an auto dump flush sequence is complete.
Be sure to spray all mixed material before potlife expires.
System detects no meter pulses, or a disruption in meter pulses lasting longer than 1 second throughout the Color/Catalyst purge time duration.
Check that meter cable is connected.
Clean or repair meter.
System detects no meter pulses, or system must detect at least 10cc of material from each side throughout the Color/Catalyst fill time duration.
Check that meter cable is connected.
Clean or repair meter.
Gun, dump valve, or correct color/catalyst valve not open.
Open the valve.
Exhausted fluid supply. Check fluid level and refill if necessary.
Switch settings (S3-S6) on color change board do not match hardware configuration.
Verify that color change board switches are set correctly. See installation manual.
Fuse F1, F2, or both are blown. Verify condition of fuses and replace if necessary. See Repair-Parts manual.
Mix fill push has been completed. Potlife expired material has been purged.

System Pneumatic Schematic
COLOR VALVE STACKS
MANIFOLD AIR EXHAUST MUFFLER
COLOR 1 COLOR 2 COLOR 3 COLOR 4 COLOR 5 COLOR 6 COLOR 7 COLOR 8 COLOR SOLVENT COLOR 9 COLOR 10 COLOR 11 COLOR 12 CATALYST 1 CATALYST 2 CATALYST 3 CATALYST 4 CATALYST SOLVENT
12 VDC
FLUSH AIR TO FLUID INLET 1/4 TUBE
CLOSE
OPEN 5/32 TUBE
DOSE A VALVE
4-WAY SOLENOID
A B
12 VDC
CLOSE
OPEN 5/32 TUBE
DOSE B VALVE
4-WAY SOLENOID
A B
12 VDC
CLOSE
OPEN 5/32 TUBE
PURGE A VALVE
4-WAY SOLENOID
A B
3/8 AIR FILTER MANUAL DRAIN 5 MICRON WALL MOUNT ONLY
12 VDC
CLOSE
OPEN 5/32 TUBE
PURGE B VALVE
COLOR 13 COLOR 14 COLOR 15 COLOR 16 COLOR 17 COLOR 18 COLOR 19 COLOR 20 COLOR 21 COLOR 22 COLOR 23 COLOR 24 COLOR 25 COLOR 26 COLOR 27 COLOR 28 COLOR 29 COLOR 30
A B
AIR INPUT
12 VDC
PURGE C VALVE (OPTIONAL) 4-WAY SOLENOID
CLOSE
OPEN 5/32 TUBE
A B
AIR EXHAUST MUFFLER
PURGE AIR
12 VDC
5/32 TUBE
DUMP A VALVE (OPTIONAL)
3-WAY SOLENOID
A
OPEN
AIR INPUT
12 VDC
OPEN 5/32 TUBE
DUMP B VALVE (OPTIONAL)
3-WAY SOLENOID
A
MAC 36 SERIES SOLENOID VALVES
12 VDC GFB 1 VALVE (OPTIONAL)
5/32 TUBE
3-WAY SOLENOID
A
OPEN
12 VDC GFB 2 VALVE (OPTIONAL)
OPEN 5/32 TUBE
3-WAY SOLENOID
A
MANIFOLD
Schematic Diagrams

NON-HAZARDOUS AREA
OPERATOR INTERFACE
LINE FILTER
L1 N GND
L1 N
DC OK
+24 VDC
+ + - -
1 2 L1 N
85-250 VAC
L1 N GND
TERMINAL BLOCK
L1 N GND
COMMON
COMMON
GND LUG
GND N L1
OPEN OPEN
85-250 VAC
POWER ROCKER SWITCH 1 2 3 4 5
1 2 1A 1B 2A 2B
POWER HARNESS
UNUSED UNUSED UNUSED UNUSED UNUSED
J1
HARNESS
1 2 3 J5
+12VDC I/S (RED) COM (BLACK) SHIELD
BARRIER BOARD
CABLE
1 2 3 J4
+24VDC OPEN COMMON
(50' STD.)/
(100' OPTION)
ALARM
J4
DISPLAY BOARD
MEMBRANE SWITCH WITH RIBBON CABLE
1 2 3 4 5 6 7 8 9 10 11
1 2 3 4
1 2 3 4 5 6
MIX INPUT PURGE INPUT JOB COMPLETE INPUT EXTERNAL CLR CHG READY RESET ALARM INPUT DIGITAL INPUT COMMON
RJ45
J6
J2
POWER DIST. TERMINAL BLOCKS
RJ45 RJ45
1 2 3 4 5 6 7 8
DIGITAL INPUT COMMON RECIPE BIT 0 INPUT RECIPE BIT 1 INPUT RECIPE BIT 2 INPUT RECIPE BIT 3 INPUT RECIPE BIT 4 INPUT RECIPE BIT 5 INPUT RECIPE CHANGE INPUT
J2
REMOTE I/O INTEGRATION BOARD
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8
DIGITAL OUTPUT COMMON/POWER PURGE/RECIPE CHG ACTIVE OUTPUT MIX ACTIVE OUTPUT MIX READY OUTPUT FILL ACTIVE FLOW CAL. ACTIVE FLOW RATE ALARM OUTPUT DIGITAL OUTPUT COMMON/POWER
J4
1 2 3 4 5 6 7 8 9 10
FLOW CONTROL CAL. (BLK) GUN TRIGGER (WHT) DIGITAL IN COMMON (RED) REMOTE STOP (GRN) ALARM RESET (BRN) ALARM OUTPUT (BLU) DIGITAL OUTPUT COMMON (ORG) POT LIFE (YEL) FLOW RATE ANALOG IN (PUR) FLOW RATE ANALOG COMMON (GRAY)
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6
DIGITAL OUTPUT COMMON/POWER SPECIAL OUTPUT #1 SPECIAL OUTPUT #2 SPECIAL OUTPUT #3 SPECIAL OUTPUT #4 DIGITAL OUTPUT COMMON/POWER
J5
I/O HARNESSES
BEACON (+24) YEL (COM) GRAY
ORG
TERMINAL BLOCKS
BRN RED
1 2 3 4 5 6
RS485 INTEGRATION A (WHT/BLU) RS485 INTEGRATION B (BLU/WHT) RS485 INTEGRATION GROUND (SHIELD) RS485 NETWORK A (WHT/ORG) RS485 NETWORK B (ORG/WHT) RS485 NETWORK GROUND (SHIELD)
1 2 3 4 5 6
CABLE
J7 J8
FO IN (BLK) FO OUT (BLU)
RJ45 RJ45 P1
RJ45 BULKHEAD
3' (25'-200' OPTIONS)
RJ45 RJ45
WEB SERVER
MODULE

FLUID PANEL CONTROL BOX
HAZARDOUS AREA
3X CABLE
FLUID PANEL CONTROL BOARD
1 2 3 4 5 6
PWR (RED) COM (BLACK) SIG (WHITE) SHIELD/GRN PWR (RED) COM (BLACK) SIG (WHITE) SHIELD/GRN PWR (RED) COM (BLACK) SIG (WHITE) SHIELD/GRN
J3
FLOW METER B
I.S. METERS
1 2 3 4 5 6
J12
J2
1 2 J1
SIG (RED) COM (BLK)
TECNO V/P
1 2 3 4 5
GROUND TERMINAL
V/P ANALOG OUT (WHT) PRESS. (GRN) +12 V (RED) GND (BLK) CHASSIS (BARE)
1 2 3 4 5 6
1 2 3 4 5
+ PRESSURE (GRN) COM (RED) EX+ (WHT) - PRESSURE (BLK) SHIELD (BARE)
FLUID PRESS. SENS.
J13
+12VDC I/S COM SHIELD
1 2 3 4 5 6
MH2
J7/J11
1 4 5 2 3
COLOR BOARD 1 (COLORS 1 THRU 12, CATALYST 1 THRU 4)
3 2 5 4 1
GRD (BLK) +12VDC (RED) SHIELD (BARE) CAN H (WHT) CAN L (BLU)
MANIFOLD 6 5 4 3 2 1
MANIFOLD
+12VDC
1 2 3 4 5 6
CLR 9
CLR 8
COM +12VDC
COM +12VDC
CLR 7
COM +12VDC
J8
J9
CLR 10
50' STD.
CLR 6
COM +12VDC
CLR 11
3 2 5 4 1
3 2 5 4 1
J7
CLR 5
+12VDC
1 2 3 4 5 6
6 5 4 3 2 1
CLR 12
CAN H (WHT)
CLR 4
COM +12VDC
J15
J16
COM +12VDC
CAN L (BLU)
COM +12VDC
CAT 4
CLR 3
COM
COM +12VDC
CAT 3
6 5 4 3 2 1
CAT 2
CLR 2
+12VDC
COM +12VDC
1 2 3 4 5 6
CLR 1
J14
J10
COM +12VDC
CAT 1
BLACK RED BLACK RED BLACK RED
DUMP B
COM +12VDC
COM +12VDC
SOL CAT
SOL CLR
COM
J8
GFB #1
3-WAY SOLENOID
1 4 5 2 3
GFB #2
6' STD.
12 VDC
J7/J11
6 5 4 3 2 1
1 4 5 2 3
J15
MANIFOLD
NOT USED
PURGE C
6 5 4 3 2 1
PURGE B
MANIFOLD
MANIFOLD 6 5 4 3 2 1
4-WAY SOLENOID
CLR 21
+12VDC
1 2 3 4 5 6
CLR 22
J14
PURGE A
CLR 20
COM +12VDC
J8
J9
COM +12VDC
COM +12VDC
CLR 23
NOT USED
12 VDC
CLR 19
COM
COM +12VDC
CLR 24
+12VDC
1 2 3 4 5 6
6 5 4 3 2 1
NOT USED
CLR 18
COM +12VDC
6 5 4 3 2 1
CLR 25
CLR 17
COM +12VDC
J15
J16
COM +12VDC
CLR 26
J9
DOSE B
CLR 16
COM +12VDC
COM
CLR 27
DOSE A
+12VDC
1 2 3 4 5 6
6 5 4 3 2 1
CLR 28
CLR 15
COM +12VDC
1 2 3 4 5 6 7 8 9 10
SIG COM SIG COM SIG COM SIG COM SIG COM
CLR 14
COM +12VDC
J14
J10
COM +12VDC
CLR 29
CLR 13
COM +12VDC
CLR 30
AIR FLOW SWITCH 2
COM
FO OUT (BLU)
J1
SOLVENT FLOW SWITCH
J4
GFB 1 PRESSURE SWITCH
FO IN (BLK)
J6
GFB 2 PRESSURE SWITCH
Schematic Diagrams · (10')/ (40')

GND
N
GRN/YEL 16 AWG
RED 16 AWG
BROWN 16 AWG
GND
N
LINE FILTER
N
ALARM
BROWN 16 AWG
RED 16 AWG
ROCKER SWITCH
1A
2A
RED 16 AWG
BROWN 16 AWG
RJ45 RJ45 BULKHEAD
N
N
VOLTAGE
HIGH
IN
POWER SUPPLY
24 VDC+ OUTPUT
GND LUG
COMMON
24 VDC+
DC OK
BLACK 18 AWG
RED 18 AWG
IS POWER
12 VDC
+12 VDC I/S (WHITE)
COMMON (BLACK)
BLACK 18 AWG
RED 18 AWG
SHIELD/GRND
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
J4-3
J4-2
J4-1
J1-5
J1-4
J1-3
J1-2
J1-1
J5-3
J5-2
J5-1
GREEN/BLACK/WHITE 22 AWG
RED/BLACK/WHITE 22 AWG
J1
J5
BLACK 18 AWG
RED 18 AWG
24 VDC+ IN
RJ45 RJ45
J4
DISPLAY BOARD
BARRIER BOARD
P1
J9
DISPLAY BOARD

Meter Performance Data (G3000 on A and B)
1:1 2:1 3:1 4:1 5:1 6:1 7:1 8:1 9:1 10:1 11:1 12:1 13:1 14:1 15:1 16:1 17:1 18:1 19:1 20:1 21:1 22:1 23:1 24:1 25:1 26:1 27:1 28:1 29:1 30:1
25cc Dose
Ratio
10cc Dose
Test Conditions

Meter Performance Data (G3000 on A, Coriolis on B)
1:1 2:1 3:1 4:1 5:1 6:1 7:1 8:1 9:1 10:1 11:1 12:1 13:1 14:1 15:1 16:1 17:1 18:1 19:1 20:1 21:1 22:1 23:1 24:1 25:1 26:1 27:1 28:1 29:1 30:1
25cc Dose
10cc Dose
25cc Dose
Ratio
Test Conditions

Maximum fluid working pressure Base system: 4000 psi (28 MPa, 280 bar)
Low pressure color change: 300 psi (2.1 MPa, 21 bar) High pressure color change: 3000 psi (21 MPa, 210 bar) Coriolis meter: 2300 psi (16.1 MPa, 161 bar) Maximum working air pressure 100 psi (0.7 MPa, 7 bar) Air supply 75 - 100 psi (0.5 - 0.7 MPa, 5.2 - 7 bar) Air filter inlet size 3/8 npt(f) Air filtration for air logic and purge air (Graco-supplied). . 5 micron (minimum) filtration required; clean and dry air Air filtration for atomizing air (user-supplied) 30 micron (minimum) filtration required; clean and dry air Mixing ratio range 0.1:1- 50:1* On-ratio accuracy up to + 1%, user selectable Fluids handled one or two component:
G3000, G250 Meter G3000HR, G250HR Meter Coriolis Meter S3000 Solvent Meter (accessory)
1/4 npt(f) 1/4 npt(f) Fluid outlet size (static mixer) 1/4 npt(f) External Power Supply Requirements 85 - 250 Vac, 50/60 Hz, 2 amps maximum draw
Flow Meter Dose Valve/Color Valve Adapters
15 amp maximum circuit breaker required 8 to 14 AWG power supply wire gauge Operating temperature range 41- 122° F (5-50° C) Environmental Conditions Rating indoor use, pollution degree (2), installation category II Noise Level
below 70 dBA below 85 dBA Wetted parts 303, 304 SST, Tungsten carbide (with nickel binder),
Sound pressure level Sound power level
* Dependent on programmed K-factor and application. The maximum allowable flow meter pulse frequency is 425 Hz (pulses/sec). For more detailed information on viscosities, flow rates, or mixing ratios, consult your Graco dis- tributor.
See individual component manuals for additional technical data.
Technical Data · perfluoroelastomer; PTFE

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
For patent information, see www.graco.com/patents
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 312776
Copyright 2008, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com Revision F, April 2015
Pages referenced in this manual — manufacturer, support and downloads.
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| E-1 | Communication Error Alarm | p.80 | |
| E-2 | Potlife Alarm | p.80 | |
| E-3 | Ratio High Alarm | p.80 | |
| E-4 | Ratio Low Alarm | p.80 | |
| E-5 | Overdose A/B Dose Too Short Alarm | p.80 | |
| E-6 | Overdose B/A Dose Too Short Alarm | p.80 | |
| E-7 | Dose Time A Alarm | p.80 | |
| E-8 E-9 | Dose Time B Alarm Not used | p.80 | |
| E-10 | Remote Stop Alarm | p.80 | |
| E-11 | Purge Volume Alarm | p.80 | |
| E-12 | CAN Network Communication Error Alarm | p.80 | |
| E-13 | High Flow Alarm | p.80 | |
| E-14 | Low Flow Alarm | p.80 | |
| E-15 | System Idle Warning | p.80 | |
| E-16 | Setup Change Warning | p.80 | |
| E-17 | Power On Warning | p.80 | |
| E-18 | Defaults Loaded Warning | p.80 | |
| E-19 | I/O Alarm | p.80 | |
| E-20 | Purge Initiate Alarm | p.80 | |
| E-21 | Material Fill Alarm | p.80 | |
| E-22 | Tank A Low Alarm | p.80 | |
| E-23 | Tank B Low Alarm | p.80 | |
| E-24 | Tank S Low Alarm | p.80 | |
| E-25 | Auto Dump Complete Alarm | p.80 | |
| E-26 | Color/Catalyst Purge Alarm | p.80 | |
| E-27 | Color/Catalyst Fill Alarm | p.80 | |
| E-28 | Mix Fill Push Complete | p.80 | |
| E-8 | gun trigger input is active (AFS or Integration) and fewer than 31 B meter pulses were detected during the | p.85 | |
| E-9 | Not used | p.86 |