Operation

ProMix ® 2KS

EN

Plural Component Proportioner

Manual system for proportional mixing of plural component coatings. For professional use only.

Approved for use in explosive atmospheres (except the EasyKey).

See page 4 for model information, including maximum working pressure. Equipment approval labels are on page 3. Some components shown are not included with all systems.

Graco Diaphragm Pump (312776F) — EN diagram (page 1)
Fig. 1

II 2 G 0359

TI12504a · # 53

Page 3 of the Graco Diaphragm Pump (312776F) user manual — Related Manuals
Page 3 · click to enlarge
Page 3

Related Manuals

Equipment Approvals

Component Manuals in English

ManualDescription 312775ProMix 2KS Manual System Installation 312777ProMix 2KS Manual System Repair-Parts 312781Fluid Mix Manifold 312782Dispense Valve 312783Color Change Valve Stacks 312787Color Change Module Kit 312784Gun Flush Box Kits 310745Gun Air Shutoff Kit 312786Dump Valve and Third Purge Valve Kits 312785Network Communication Kits 308778G3000/G3000HR Flow Meter 313599Coriolis Flow Meter 313290Floor Stand Kit 313542Beacon Kit 313386Basic Web Interface/Advanced Web Interface 40679915V256 Automatic System Upgrade Kit 40680015V825 Discrete I/O Board Kit

EasyKey and Fluid Station Label

ATEX Certificate is listed here

Graco Diaphragm Pump (312776F) — Related Manuals diagram (page 3)
Fig. 2 · Related Manuals

!"#$#%% & ' ( ( )* + ) , - ( + . /+0 1% 2* 3

2 1 3/% 1 4 5 6 '( # &'(

3 ( ( 9 88 $$!% +1 &&88

Graco Diaphragm Pump (312776F) — Related Manuals diagram (page 3)
Fig. 3 · Related Manuals

Intrinsically safe equipment for Class I, Div 1, Group D, T3 Ta = -20°C to 50°C Install per 289833 FM08ATEX0073 II 2 G Ex ia IIA T3

GRACO INC. P.O. Box 1441 Minneapolis, MN 55440 U.S.A.

ATEX Certificate is listed here

Graco Diaphragm Pump (312776F) — Related Manuals diagram (page 3)
Fig. 4 · Related Manuals

Intrinsically safe connections for Class I, Div 1, Group D Ta = -20°C to 50°C Install per 289833 C US 50/60 Hz

GRACO INC. P.O. Box 1441 Minneapolis, MN 55440 U.S.A. II (2) G [Ex ia] IIA FM08ATEX0072

ATEX Certificate is listed here

Related Manuals · Fluid Station Label · EasyKey Label

Page 4 of the Graco Diaphragm Pump (312776F) user manual — System Configuration and Part Numbers
Page 4 · click to enlarge
Page 4

System Configuration and Part Numbers

System Configuration and Part Numbers

Configurator Key

The configured part number for your equipment is printed on the equipment identification labels. See FIG. 1 for location of the identification labels. The part number includes one digit from each of the following six categories, depending on the configuration of your system. Manual SystemControl and DisplayA and B MeterColor ValvesCatalyst ValvesApplicator Handling MD = EasyKey with LCD Display0 = No Meters 1 = G3000 (A and B) 2 = G3000HR (A and B) 3 = 1/8 in. Coriolis (A) and G3000 (B) 4 = G3000 (A) and 1/8 in. Coriolis (B) 5 = 1/8 in. Coriolis (A) and G3000HR (B) 6 = G3000HR (A) and 1/8 in. Coriolis (B) 7 = 1/8 in. Coriolis (A and B)0 = No Valves (single color) 1 = Two Valves (low pressure) 2 = Four Valves (low pressure) 3 = Seven Valves (low pressure) 4 = Twelve Valves (low pressure) 5 = Two Valves (high pressure) 6 = Four Valves (high pressure)0 = No Valves (single catalyst) 1 = Two Valves (low pressure) 2 = Four Valves (low pressure) 3 = Two Valves (high pressure)1 = One Air Flow Switch Kit 2 = Two Air Flow Switch Kits 3 = One Gun Flush Box Kit 4 = Two Gun Flush Box Kits
Graco Diaphragm Pump (312776F) — System Configuration and Part Numbers diagram (page 4)
Fig. 5 · System Configuration and Part Numbers
Graco Diaphragm Pump (312776F) — System Configuration and Part Numbers diagram (page 4)
Fig. 6 · System Configuration and Part Numbers

!"#$" %#$!

!"#$#%% & ' ( ( )* + ) , - ( + . /+0 1% 2* 3

( 78 3 4

Label Location on EasyKey Label Location on Fluid Station

$#$+" , +-! !./%0!$# - ( ++ 1

2 1 3/% 1 4 5 6 '( # &'(

Maximum Fluid Working Pressure

3

3 ( ( 9 88 $$!% +1 &&88

&'( ) '*

F IG . 1Identification Label
Show 7 more labels / short text on this page
· TI12418a TI12423a · · · · Configured Part Number · is listed here
Page 5 of the Graco Diaphragm Pump (312776F) user manual — Standard Features
Page 5 · click to enlarge
Page 5

System Configuration and Part Numbers

Models using a G3000, G3000HR, or intrinsically safe Coriolis meter for both A and B meters are approved for installation in a Hazardous Location - Class I, Div I, Group D, T3 or Zone I Group IIA T3.

Maximum working pressure rating is dependent on the fluid component options selected. The pressure rating is based on the rating of the lowest rated fluid component. Refer to the component pressure ratings below. Example: Model MD2531 has a maximum working pressure of 3000 psi (21 MPa, 210 bar).

Check the identification label on the EasyKey or fluid station for the system maximum working pressure. See FIG. 1.

ProMix Fluid Components Maximum Working Pressure

Base System (no meters [option 0], no color/catalyst change [option 0]) 4000 psi (27.58 MPa, 275.8 bar) Meter Option 1 and 2 (G3000 or G3000HR) 4000 psi (27.58 MPa, 275.8 bar) Meter Option 3, 4, 5, 6, and 7 (one or two Coriolis Meters) 2300 psi (15.86 MPa, 158.6 bar) Color Change Option 1, 2, 3 and 4 and Catalyst Change Option 1 and 2 (low pressure valves) 300 psi (2.07 MPa, 20.6 bar) Color Change Option 5 and 6 and Catalyst Change Option 3 (high pressure valves) 3000 psi (21 MPa, 210 bar)

Flow Meter Fluid Flow Rate Range

G3000 75-3800 cc/min. (0.02-1.0 gal./min.) G3000HR 38-1900 cc/min. (0.01-0.50 gal./min.) Coriolis Meter 20-3800 cc/min. (0.005-1.00 gal./min.) S3000 Solvent Meter (accessory) 38-1900 cc/min. (0.01-0.50 gal./min.)

Standard Features

Fiber Optic and Power Cables, 50 ft (15.25 m)

Wall Mount Fluid Station, 50 cc Integrator and Static Mixer

B Side Dump Valve, if multiple catalyst valves

Show 6 more labels / short text on this page
Hazardous Location Approval · Maximum Working Pressure · Feature · EasyKey with LCD · Booth Control · Basic Web Interface
Page 6 of the Graco Diaphragm Pump (312776F) user manual — Accessories
Page 6 · click to enlarge
Page 6

Accessories

Gun Flush Box Gun Insert Selection

15V354 Third Purge Valve Kit

15V536 Solvent Flow Switch Kit

15V213 Power Cable, 100 ft (30.5 m)

15G710 Fiber Optic Cable, 100 ft (30.5 m)

15U955 Injection Kit for Dynamic Dosing

15V034 10 cc Integrator Kit

15V033 25 cc Integrator Kit

15V021 50 cc Integrator Kit

24B618 100 cc Integrator Kit

15W034 Strobe Light Alarm Indicator Kit

15V337 Advanced Web Interface

15V256 Automatic Mode Upgrade Kit

16D329 S3000 Solvent Flow Meter Kit

15V825 Discrete I/O Integration Board Kit

Accessories · Accessory

Page 7 of the Graco Diaphragm Pump (312776F) user manual — Warnings
Page 7 · click to enlarge
Page 7

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). • Keep work area free of debris, including solvent, rags and gasoline. • Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present. • Ground all equipment in the work area. See Grounding instructions. • Use only grounded hoses. • Hold gun firmly to side of grounded pail when triggering into pail. • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. • Keep a working fire extinguisher in the work area. ELECTRIC SHOCK HAZARD This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock. • Turn off and disconnect power at main switch before disconnecting any cables and before servicing equipment. • Connect only to grounded power source. • All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations. INTRINSIC SAFETY Intrinsically safe equipment that is installed improperly or connected to non-intrinsically safe equipment will create a hazardous condition and can cause fire, explosion, or electric shock. Follow local regulations and the following safety requirements. • Only models with a G3000, G250, G3000HR, G250HR, or intrinsically safe Coriolis meter are approved for installation in a Hazardous Location - Class I, Div I, Group D, T3 or Zone I Group IIA T3. • Do not install equipment approved only for a non-hazardous location in a hazardous area. See the ID label for the intrinsic safety rating of your model. • Do not substitute or modify system components as this may impair intrinsic safety.
Page 8 of the Graco Diaphragm Pump (312776F) user manual — Warnings
Page 8 · click to enlarge
Page 8
WARNING SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. • Tighten all fluid connections before operating the equipment. • Do not point gun at anyone or at any part of the body. • Do not put your hand over the spray tip. • Do not stop or deflect leaks with your hand, body, glove, or rag. • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment. EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only. • Do not alter or modify equipment. • Use equipment only for its intended purpose. Call your distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or over bend hoses or use hoses to pull equipment. • Keep children and animals away from work area. • Comply with all applicable safety regulations. TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read MSDS’s to know the specific hazards of the fluids you are using. • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. • Always wear chemically impermeable gloves when spraying or cleaning equipment. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to: • Protective eyewear • Clothing and respirator as recommended by the fluid and solvent manufacturer • Gloves • Hearing protection
Page 9 of the Graco Diaphragm Pump (312776F) user manual — Keep Components A and B Separate
Page 9 · click to enlarge
Page 9

Important Two-Component Material Information

Isocyanate Conditions

Moisture Sensitivity of Isocyanates

Isocyanates (ISO) are catalysts used in two component coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in vis- cosity. If used, this partially cured ISO will reduce perfor- mance and the life of all wetted parts.

Spraying or dispensing materials containing isocya- nates creates potentially harmful mists, vapors, and atomized particulates.

Read material manufacturer’s warnings and mate- rial MSDS to know specific hazards and precautions related to isocyanates.

Prevent inhalation of isocyanate mists, vapors, and atomized particulates by providing sufficient ventila- tion in the work area. If sufficient ventilation is not available, a supplied-air respirator is required for everyone in the work area.

To prevent exposing ISO to moisture:

  • Always use a sealed container with a desiccant dryer in the vent, or a nitrogen atmosphere. Never store ISO in an open container.

To prevent contact with isocyanates, appropriate personal protective equipment, including chemically impermeable gloves, boots, aprons, and goggles, is also required for everyone in the work area.

  • Use moisture-proof hoses specifically designed for ISO, such as those supplied with your system.
  • Never use reclaimed solvents, which may contain moisture. Always keep solvent containers closed when not in use.

Material Self-ignition

  • Never use solvent on one side if it has been contaminated from the other side.
  • Always lubricate threaded parts with ISO pump oil or grease when reassembling.

Some materials may become self-igniting if applied too thickly. Read material manufacturer’s warnings and material MSDS.

Changing Materials

  • When changing materials, flush the equipment multiple times to ensure it is thoroughly clean.

Keep Components A and B Separate

  • Always clean the fluid inlet strainers after flushing.
  • Check with your material manufacturer for chemical compatibility.
  • Most materials use ISO on the A side, but some use ISO on the B side.

Cross-contamination can result in cured material in fluid lines which could cause serious injury or dam- age equipment. To prevent cross-contamination of the equipment’s wetted parts, never interchange component A (isocyanate) and component B (resin) parts.

Page 10 of the Graco Diaphragm Pump (312776F) user manual — Glossary of Terms
Page 10 · click to enlarge
Page 10

Glossary of Terms

Advanced Web Interface (AWI) - This allows remote ProMix backup and restore, configuration, logging, and software update options.

Coriolis Meter - a non-intrusive flow meter often used in low flow applications or with light viscosity, shear sensi- tive, or acid catalyzed materials. This meter uses vibra- tion to measure flow.

Air Chop - the process of mixing air and solvent together during the flush cycle to help clean the lines and reduce solvent usage.

Custom Language - A method to load a translation file into the ProMix to display languages other than those built into the system. Only Unicode characters through codespace 0x00FF are supported.

Air Chop Time- duration of each activation of the air purge valve during a chop sequence. User settable from 0.0-99.9 seconds.

Digital Input and Output - a description of data which is transmitted as a sequence of discrete symbols, most commonly this means binary data represented using electronic or electromagnetic signals.

Analog - relating to, or being a device in which data are represented by continuously variable, measurable, physical quantities, such as length, width, voltage, or pressure.

Discrete I/O - refers to data that constitutes a separate entity and has direct communication to another control.

B Purge After Chop - Optional 2-second B solvent valve activation after the Chop sequence. This is used to separate the chop material and the Final Purge mate- rial to prevent unwanted mixing.

Dose Size - the amount of resin (A) and catalyst (B) that is dispensed into an integrator.

Dose Time Alarm - the amount of time that is allowed for a dose to occur before an alarm occurs. More than 30 pulses from the flow meter of the active dose valve are needed while the Gun Trigger is on to prevent the alarm.

Basic Web Interface (BWI) - This allows remote Pro- Mix backup and restore, logging, and software update options.

Bootloader - The utility program that handles initial sys- tem startup re-programming of the main ProMix applica- tion.

Dynamic Dosing - Component A dispenses constantly. Component B dispenses intermittently in the necessary volume to attain the mix ratio.

Chop Time- refers to the total length of the chop sequence during a purge. User settable from 0-999 sec- onds.

Ethernet - a method for directly connecting a computer to a network or equipment in the same physical location.

Closed Loop Flow Control - refers to the process when the flow rate is adjusted automatically to maintain a constant flow.

ExtSP - External Set Point selection for PLC input of the flow rate set point while operating in Flow Control Over- ride mode.

Color/Catalyst Purge - refers to the time required to flush the lines from the color or catalyst change module to the mix manifold during a color or catalyst change.

Fiber Optic Communication - the use of light to trans- mit communication signals. Blue is the transmitter, and black is the receiver. This must be cross-connected between the EasyKey and the Fluid Panel for communi- cation to work. The Fiber Optic cable has a blue band to indicate the proper connection.

Color/Catalyst Fill - refers to the time required to fill the lines from the color or catalyst change module to the mix manifold.

Final Purge Source- source of the media used in the final purge cycle. User settable to air purge valve, sol- vent purge valve, or 3rd purge valve.

Command Holdoff - The amount of time that flow rate learning is not allowed after the set point is changed to allow the flow rate to stabilize.

Final Purge Time- duration of the final purge cycle. User settable from 0-999 seconds.

Glossary of Terms

Page 11 of the Graco Diaphragm Pump (312776F) user manual — Glossary of Terms
Page 11 · click to enlarge
Page 11

First Purge Source- source of the media used in the first purge cycle. User settable to air purge valve, sol- vent purge valve, or 3rd purge valve

K-factor - a value that refers to the amount of material that passes through a meter. The assigned value refers to an amount of material per pulse.

First Purge Time- duration of the first purge cycle. User settable from 0-999 seconds.

Kd - refers to the amount the fluid flow system attempts to not overshoot the target set point.

Flow Control Resolution - a settable value that allows the flow control system to maximize its performance. The value is based on maximum desired flow rates.

Ki - refers to the degree fluid flow over shoots its set point.

Kp - refers to the speed in which the fluid flow reaches its set point.

Flow Rate Analog Signal - the type of communication signal that can be used on the ProControl module.

Learn Strength - How much and how quickly to apply the difference in the flow rate set point compared to the measured flow rate when updating the flow control data table.

Flow Rate Tolerance - the settable percent of accept- able variance that the system will allow before a flow rate warning occurs.

Flow Set Point - a predefined flow rate target.

Manual Mode - when the proportioning or flow control system is controlling the inputs without any input from an outside control.

Flush Volume Check - system monitors flush volume. E-11 Alarm occurs if minimum volume is not achieved. Minimum flush volume is user settable (0-999 cc).

Minimum Material Fill Volume - system monitors material fill volume. E-21 Alarm occurs if minimum vol- ume is not achieved. Minimum material fill volume is user settable (0-9999 cc).

Global - indicates that values on the screen apply to all recipes, 1 through 60.

Grand Total - a non-resettable value that shows the total amount of material dispensed through the system.

Mix - when cross-linking of the resin (A) and catalyst (B) occurs.

GT-Off Drive Time - The amount of time to regulate the fluid pressure based on the flow rate set point after the gun trigger is closed.

Mix Fill Push - An option for the Autodump selection to automatically clear the Potlife alarm if the gun is in the Gun Flush Box by running new mixed material through the gun.

GT-Off Target Rise - The additional time to regulate the fluid pressure based on the flow rate set point after the gun trigger is closed.

Mix Input Signal- refers to system mode status where system begins a dose sequence each time the mix sig- nal is made “High”.

Gun Trigger Holdoff - The amount of time that flow rate learning is not allowed after the gun trigger is opened to allow the flow rate to stabilize.

Mixed Material Fill Time - the amount of time that is required to load mixed material from the dose valves to the applicator/gun.

Gun Trigger Input Signal - used to manage ratio assurance dose times and flow control processes.

Modbus/TCP - a type of communication protocol used to communicate Digital I/O signals over an ethernet.

Intrinsically Safe (IS) - refers to the ability to locate cer- tain components in a hazardous location.

Network Station - a means to identify a particular indi- vidual proportioning or flow control system.

Idle - if the gun is not triggered for 2 minutes the system enters Idle mode. Trigger the gun to resume operation.

One-Point Learning - Flow Control table calibration method using learned points above a specified flow rate to interpolate the table at low flow rates with short gun trigger times.

Job Total - a resettable value that shows the amount of material dispensed through the system for one job. A job is complete when a color change or complete system flush occurs.

Glossary of Terms

Page 12 of the Graco Diaphragm Pump (312776F) user manual — Glossary of Terms
Page 12 · click to enlarge
Page 12

Overdose (A, B, C) Alarm - when either the resin (A), or catalyst (B), or reducer (C) component dispenses too much material and the system cannot compensate for the additional material.

Third Purge Valve - refers to the use of three purge valves used to flush some waterborne materials. The valves are used to flush with water, air and solvent.

V/P - refers to the voltage to pressure device in the flow control module.

Potlife Time - the amount of time before a material becomes unsprayable.

Valve Holdoff Maximum - The maximum amount of time that flow rate learning is not allowed after a dose valve cycles. The system may internally use a time less than is based on the stability of the fluid meter pulse stream.

Potlife Volume - the amount of material that is required to move through the mix manifold, hose and applicator before the potlife timer is reset.

Purge - when all mixed material is flushed from the sys- tem.

Purge Drive - The voltage drive during the Purge sequence, maximum of 3300 mV. The response curve of the V/P regulator is not linear, so it may be necessary to test the response using Manual Override mode.

Purge Time - the amount of time required to flush all mixed material from the system.

Purge Volume Alarm - E-11 Alarm occurs if minimum flush volume is not achieved.

Ratio Tolerance - the settable percent of acceptable variance that the system will allow before a ratio alarm occurs.

Sequential Color Change - the process when a color change is initiated and the system automatically flushes the old color and loads a new color.

Sequential Dosing - Components A and B dispense sequentially in the necessary volumes to attain the mix ratio.

Solvent/3rd Purge Valve Chop Time- duration of each activation of the solvent or 3rd purge valve during a chop sequence. User settable from 0.0-99.9 seconds.

Solvent Fill - the time required to fill the mixed material line with solvent.

Solvent Push - enables the user to save some mixed material by pushing it out to the gun with solvent. Requires an accessory solvent meter.

Standby - refers to the status of the system.

System Idle - This warning occurs if the ProMix is set to Mix, and 2 minutes have elapsed since the system received a flow meter pulse.

Glossary of Terms

Page 13 of the Graco Diaphragm Pump (312776F) user manual — Component Identification and Definition
Page 13 · click to enlarge
Page 13

Overview

Usage

The Graco ProMix 2KS is an electronic two-component paint proportioner. It can blend most two-component solvent and waterborne epoxy, polyurethane, and acid-catalyzed paints. It is not for use with “quick-setting” paints (those with a potlife of less than 15 minutes).

  • Can proportion at ratios from 0.1:1 to 50:1 in 0.1 increments with the wall mount fluid station.
  • Has user selectable ratio assurance and can maintain up to +/-1% accuracy, depending on materials and operating conditions.
  • Models are available to operate air spray or air-assisted systems with a capacity of up to 3800 cc/min.
  • Color change options are available for low pressure (300 psi [2.1 MPa, 21 bar]) air spray and high pressure (3000 psi [21 MPa, 210 bar]) systems with up to 30 color change valves and up to 4 catalyst change valves.

Component Identification and Definition

See Table 1, FIG. 2, and FIG. 3 for the system components.

Table 1Component Descriptions

EasyKey (EK) Used to set up, display, operate, and monitor the system. The EasyKey accepts 85-250 VAC, 50/60 Hz line power and converts that power to acceptable low voltage and optical signals used by other system components.

Booth Control (BC) Used by the operator for daily painting functions including: choosing recipes, initiating job complete, reading/clearing alarms, and placing the system in Standby, Mix, or Purge mode. It is typically mounted inside the booth or near the painter.

Fluid Station (ST) Includes air control solenoids, flow switches, and mountings for the fluid flow meters and the fluid manifold assembly. Its control board manages all proportioning functions.

  • Fluid Manifold (FM)
  • Pneumatically Operated Dose Valves for component A and B
  • Purge Valves for solvent and air purge
  • Sampling Valves for calibrating the flow meters and performing ratio checks
  • Shutoff Valves for component A and B to close their fluid passages to the mix manifold, to allow for accurate calibration and ratio checks
  • Mix Manifold , which includes the fluid integrator and static mixer.

Fluid Integrator is the chamber where component A and B align at the selected ratio and begin to mix. Static Mixer has 24 elements to uniformly blend the materials downstream of the fluid integrator.

Overview · Component Description

Page 14 of the Graco Diaphragm Pump (312776F) user manual — Overview
Page 14 · click to enlarge
Page 14
Table 1Component Descriptions

Three optional flow meters are available from Graco:

Flow Meters (MA, MB, MS)

  • G3000 is a general purpose gear meter typically used in flow ranges of 75-3800 cc/min. (0.02–1.0 gal/min.), pressures up to 4000 psi (28 MPa, 276 bar), and viscosities of 20–3000 centipoise. The K-factor is approximately 0.119 cc/pulse.
  • G3000HR is a high resolution version of the G3000 meter. It is typically used in flow ranges of 38–1900 cc/min. (0.01–0.5 gal/min.), pressures up to 4000 psi (28 MPa, 276 bar). and viscosities of 20–3000 centipoise. The K-factor is approximately 0.061 cc/pulse.
  • S3000 is a gear meter used for solvents in flow ranges of 38-1900 cc/min. (0.01–0.50 gal/min.), pressures up to 3000 psi (21 MPa, 210 bar), and viscosities of 20–50 centipoise. The K-factor is approximately 0.021 cc/pulse. Required to use the Solvent Push feature.
  • Coriolis is a specialty meter capable of a wide range of flow rates and viscosities. This meter is available with 1/8 in. or 3/8 in. diameter fluid passages. For detailed information on the Coriolis meter, see manual 313599. The K-factor is user-settable; at lower flow rates use a lower K-factor.

1/8 in. fluid passages: set K-factor to .020 or .061. 3/8 in. fluid passages: set K-factor to .061 or 0.119.

Color Change Valves (ACV) and Color Change Module (CCM)

An optional component. It is available as a color change valve stack for either low or high pressure with up to 30 color change valves. Each stack includes one additional valve for solvent to clean the fluid line between color changes.

An optional component. It is available as a catalyst change valve stack for either low or high pressure with up to 4 catalyst change valves. Each stack includes one additional valve for solvent to clean the fluid line between catalyst changes.

Catalyst Change Valves (BCV)

Dual Fiber Optic Cable (FO)

Used to communicate between the EasyKey and Wall Mount Fluid Station.

Used to provide power to the Wall Mount Fluid Station.

Fluid Station Power Supply Cable (PS)

Applicator Handlinguse Air Flow Switch (AFS) or Gun Flush Box (GFB)

Air Flow Switch: The air flow switch detects air flow to the gun and signals the ProMix controller when the gun is being triggered. The switch functions with the flow meters to ensure that the system components are functioning correctly. See page 52 for further information.

Gun Flush Box: The gun flush box kit provides an automated flushing system for manual spray guns, and includes an air flow switch.

Overview · Component Description

Page 15 of the Graco Diaphragm Pump (312776F) user manual — EK
Page 15 · click to enlarge
Page 15

EK

CCM

PS

BC

BCV

FO

ACV

MS

ST

MA

MB

FM GFB

FIG. 2. Manual System, shown with G3000 Meters, Color/Catalyst Change, One Gun Flush Box, and Accessory Solvent Flow Meter

Overview · TI12504a

Page 16 of the Graco Diaphragm Pump (312776F) user manual — MS
Page 16 · click to enlarge
Page 16

DVA

FI

MB DVB

Graco Diaphragm Pump (312776F) — DVA diagram (page 16)
Fig. 7

MS

MA

RVB

AT

APV

RVA

SVA SVB

SM

SPV

FIG. 3. Wall Mount Fluid Station

Key: MA Component A Meter DVA Component A Dose Valve RVA Component A Sampling Valve SVA Component A Shutoff Valve MB Component B Meter DVB Component B Dose Valve RVB Component B Sampling Valve SVB Component B Shutoff Valve MS Solvent Meter (accessory) SPV Solvent Purge Valve APV Air Purge Valve SM Static Mixer FI Fluid Integrator AT Air Purge Valve Air Supply Tube

Overview · TI12556b

Page 17 of the Graco Diaphragm Pump (312776F) user manual — TI11614A
Page 17 · click to enlarge
Page 17

Booth Control

Used by the operator for daily painting functions includ- ing: changing recipes, signalling job complete, read- ing/clearing alarms, and placing the system in Standby, Mix, or Purge mode. It is typically mounted inside the booth or near the painter.

Table 2Booth Control Key and Indicator Functions

(see FIG. 4)

Graco Diaphragm Pump (312776F) — Booth Control diagram (page 17)
Fig. 8 · Booth Control
Table 2Booth Control Key and Indicator Functions

(see FIG. 4)

Key/Indicator Definition and Function

  • Display
  • Displays recipe number in Run mode.
  • If an alarm occurs, displays the alarm code (E1 to E28) and red Alarm indicator blinks.
  • Recipe number displays after alarm is reset.
  • If Solvent Push is on, display alternately shows dashes and the percentage remaining (see page 63).
  • Mix Mode Key
  • Starts Mix mode.
  • Green LED remains lit while in Mix mode or in Idle mode.
  • Press and hold for 5 seconds to turn on the Solvent Push feature.
  • Starts Standby mode.
  • Green LED remains lit while in Standby mode.
  • Green LED stays lit while a recipe is in use.
  • Starts Purge mode.
  • Green LED remains lit while in Purge mode.
  • LED shuts off when Up or
  • Down keys are pressed or if an alarm occurs.
  • LED blinks while a new recipe is loading and turns solid after loading is complete.
  • LED blinks when purging.
  • Select a new recipe by pressing
Graco Diaphragm Pump (312776F) — Booth Control diagram (page 17)
Fig. 9 · Booth Control

Up or Down keys, then

pressing Enter .

Alarm Reset Key and Indicator

  • Red LED blinks when an alarm occurs.
  • Press key to reset alarm. LED shuts off after alarm is reset.

Job Complete Key and Indicator

  • Signals that job is complete, and resets A and B totalizers.
  • Green LED blinks once after key is pressed.

TI11614A

Enter Key Enters selected recipe and starts color change sequence.

FIG. 4. Booth Control (see Table 2)

Show 5 more labels / short text on this page
Booth Control · Recipe Indicator · Alarm Indicator (red) · Display · Recipe Indicator (green)
Page 18 of the Graco Diaphragm Pump (312776F) user manual — Keypad
Page 18 · click to enlarge
Page 18

EasyKey Display and Keypad

EasyKey Display and Keypad

Graco Diaphragm Pump (312776F) — EasyKey Display and Keypad diagram (page 18)
Fig. 10 · EasyKey Display and Keypad

TI11630A

Navigation Keys Alarm Reset Key

FIG. 5. EasyKey Display and Keypad

Display

Table 3EasyKey Keypad Functions (see F IG . 5)

Shows graphical and text information related to setup and spray operations. Back light will turn off after 10 minutes without any key press. Press any key to turn back on.

Graco Diaphragm Pump (312776F) — Display diagram (page 18)
Fig. 11 · Display

Enter: if cursor is in menu box, press Enter key to view menu. Press Enter to save a value either keyed in from the numerical keypad or selected from a menu.

Up Arrow: move to previous field or menu item, or to previous screen within a group.

Keypad

Down Arrow: move to next field or menu item, or to next screen within a group.

Used to input numerical data, enter setup screens, scroll through screens, and select setup values.

In addition to the numbered keys on the EasyKey key- pad, which are used to enter values in setup, there are keys to navigate within a screen and between screens, and to save entered values. See Table 3.

Alarm Reset: resets all active alarms. If the display becomes unresponsive, pressing this key 4 times in succession will re-initialize the display.

Keypad LCD Display

Page 19 of the Graco Diaphragm Pump (312776F) user manual — Ethernet Connection
Page 19 · click to enlarge
Page 19

EasyKey Display and Keypad

Audible Alarm Fiber Optic Strain Relief Port

Graco Diaphragm Pump (312776F) — EasyKey Display and Keypad diagram (page 19)
Fig. 12 · EasyKey Display and Keypad

Main Power Access Port

I/S Power Discrete I/O Cable Connector Ports Ground Screw

FIG. 6. EasyKey Connections and AC Power Switch

AC Power Switch

Graco Web Interface Port

Turns system AC power on or off.

Used to communicate from a PC to:

  • Upgrade software View software version Download
  • Job and alarm logs
  • Material usage report
  • Setup values (can also upload) Clear job, alarm, and material usage reports Upload a custom language to view on screen Restore factory defaults Restore setup password

I/S Power

Power circuit to Fluid Station.

Audible Alarm

Alerts the user when an alarm occurs. Available settings for selecting which alarms will cause an audible alarm are explained in Configure Screen 1, page 29.

Clear the audible alarm by pressing the Alarm Reset

See manual 313386 for more information.

key.

Ethernet Connection

Even after the Alarm Reset key is pressed, the Potlife Exceeded alarm message will remain displayed until a sufficient amount of mixed material has been dispensed to ensure that the expired material has been ejected.

You can access data on an office or industrial network through the internet with the proper configuration. See manual 313386 for more information.

AC Power · Graco Web Interface · TI12638a TI12657a

Page 20 of the Graco Diaphragm Pump (312776F) user manual — Splash Screen
Page 20 · click to enlarge
Page 20

Run Mode Screens

Splash Screen

At power up, the Graco logo and software revision will display for approximately 5 seconds, followed by the

Status Screen (see page 22).

Graco Diaphragm Pump (312776F) — Splash Screen diagram (page 20)
Fig. 13 · Splash Screen

FIG. 7. Splash Screen

The Splash screen will also momentarily display “Estab- lishing Communication.” If this display remains for more than one minute, check that the fluid station circuit board is powered up (LED is on) and that the fiber optic cable is properly connected (see installation manual).

Graco Diaphragm Pump (312776F) — Splash Screen diagram (page 20)
Fig. 14 · Splash Screen

FIG. 8. Fluid Plate Programming Screen

Run Mode Screens

Page 21 of the Graco Diaphragm Pump (312776F) user manual — Run Mode Screens
Page 21 · click to enlarge
Page 21
Graco Diaphragm Pump (312776F) — Run Mode Screens diagram (page 21)
Fig. 15 · Run Mode Screens
Graco Diaphragm Pump (312776F) — Run Mode Screens diagram (page 21)
Fig. 16 · Run Mode Screens
Graco Diaphragm Pump (312776F) — Run Mode Screens diagram (page 21)
Fig. 17 · Run Mode Screens

Press the Setup key to enter Setup mode.

Graco Diaphragm Pump (312776F) — Run Mode Screens diagram (page 21)
Fig. 18 · Run Mode Screens
Graco Diaphragm Pump (312776F) — Run Mode Screens diagram (page 21)
Fig. 19 · Run Mode Screens
Graco Diaphragm Pump (312776F) — Run Mode Screens diagram (page 21)
Fig. 20 · Run Mode Screens
Graco Diaphragm Pump (312776F) — Run Mode Screens diagram (page 21)
Fig. 21 · Run Mode Screens
Graco Diaphragm Pump (312776F) — Run Mode Screens diagram (page 21)
Fig. 22 · Run Mode Screens
Graco Diaphragm Pump (312776F) — Run Mode Screens diagram (page 21)
Fig. 23 · Run Mode Screens
Graco Diaphragm Pump (312776F) — Run Mode Screens diagram (page 21)
Fig. 24 · Run Mode Screens
Graco Diaphragm Pump (312776F) — Run Mode Screens diagram (page 21)
Fig. 25 · Run Mode Screens

FIG. 9. Run Screens Map

Run Mode Screens · TI12783a

Page 22 of the Graco Diaphragm Pump (312776F) user manual — Status Screen
Page 22 · click to enlarge
Page 22

Status Screen

Potlife Timer: shows remaining potlife time in min- utes. Two times are shown if there are two guns.

  • Use the Up or Down keys to scroll through the Run screens.

Status Bar: shows current alarm or operation mode (standby, mix, purge, recipe change, or the current alarm).

  • Press the Setup key to enter the Setup screens

from the Status screen.

Current Flow Rate: in cc/min.

  • The other keys have no function in this Status screen.

Animation: when the gun is triggered, the gun appears to spray and the component A or B hose lights up, showing which component dose valve is open.

Graco Diaphragm Pump (312776F) — Status Screen diagram (page 22)
Fig. 26 · Status Screen

Current Date and Time

Screen Number and Scroll Arrows: displays the current screen number and the total number of screens in a group. The Up and Down arrows on the right edge of the screen indicate the scroll feature. The total number of screens in some groups may vary depending on system configuration selections.

Lock Symbol: indicates that Setup screens are password protected. See page 26. FIG. 10. Status Screen

Key to FIG. 10:

Active Recipe: shows the active recipe.

Target Ratio: for the active recipe. The ratio can be from 0.0:1–50.0:1, in 0.1 increments.

Actual Ratio: in hundredths, calculated after each dose of A and B.

Run Mode Screens

Page 23 of the Graco Diaphragm Pump (312776F) user manual — Reset Solvent Screen
Page 23 · click to enlarge
Page 23

Totals Screen

Reset Total Screen

FIG. 11. Totals Screen

FIG. 12. Reset Total Screen

This screen shows the job totals, fill totals, grand totals, and job number. Use the tabs to reset job totals (Job Complete), reset solvent totals (Rst Solvent), or go to Level Control Screen, page 24.

If job is reset, job number will increment by one for default.

Reset Solvent Screen

The job totals generally refer to material dispensed while in Mix mode. This is likely atomized and sprayed material with the gun trigger “On”.

The fill totals generally refer to material dispensed while in Mix-fill mode after a color change or a purge opera- tion. This is likely not sprayed or atomized, and is dis- pensed to a purge container.

Solvent Totals and the Rst Solvent tab only appear if “Meter” is selected under Solvent Monitor in Configure Screen 5 on page 31.

FIG. 13. Reset Solvent Total Screen

The screen will ask if you want to reset solvent total. Select Yes or No.

Run Mode Screens

Page 24 of the Graco Diaphragm Pump (312776F) user manual — Level Control Screen
Page 24 · click to enlarge
Page 24

Alarms Screens

occur after 25% of the remaining volume is mixed. Refill tank volume to clear the alarm.

Graco Diaphragm Pump (312776F) — Alarms Screens diagram (page 24)
Fig. 27 · Alarms Screens

FIG. 14. Alarms Screen

FIG. 16. Tank Level Low Screen (Tank A Shown)

Two screens show the last 10 alarms. Use the Up or

Down keys to scroll between the two screens.

See Table 10 on page 80 for a list of alarm codes.

Level Control Screen

FIG. 15. Level Control Screen

This screen shows the current volume for each fluid. Adjust the current volumes on this screen, or use the tab to go to Usage (Totals Screen, page 23). The Alarm Level values may be adjusted using the advanced web interface.

See FIG. 16. If the tank volume reaches the low-level threshold, the EasyKey screen will display the Tank Level Low alarm and prompt the user to do one of the following:

1. Refill tank volume to clear the alarm.
2. Resume mixing by selecting “Spray 25% of Remainder.” If this selection is chosen, a second alarm will

Run Mode Screens

Page 25 of the Graco Diaphragm Pump (312776F) user manual — Setup Mode
Page 25 · click to enlarge
Page 25

Setup Mode

Press the Setup key to enter Setup mode. NOTE: See FIG. 17 for a map of the Setup screens. Detailed screen descriptions follow.

Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 25)
Fig. 28 · Setup Mode

Press the Setup key to enter Setup mode.

Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 25)
Fig. 29 · Setup Mode
Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 25)
Fig. 30 · Setup Mode
Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 25)
Fig. 31 · Setup Mode
Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 25)
Fig. 32 · Setup Mode

This screen appears only if a

password is activated.

Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 25)
Fig. 33 · Setup Mode
Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 25)
Fig. 34 · Setup Mode
Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 25)
Fig. 35 · Setup Mode
Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 25)
Fig. 36 · Setup Mode

To access Advanced Setup Screens, page 34

and Recipe Setup Screens, page 38.

To access System Configuration

Screens, page 28.

Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 25)
Fig. 37 · Setup Mode

Press the Setup key to exit Setup mode and return to the Status

screen.

Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 25)
Fig. 38 · Setup Mode
Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 25)
Fig. 39 · Setup Mode
Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 25)
Fig. 40 · Setup Mode

This screen appears momentarily

if a password is activated.

Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 25)
Fig. 41 · Setup Mode

FIG. 17. Setup Screens Map

Setup Mode · TI12784a

Page 26 of the Graco Diaphragm Pump (312776F) user manual — Password Screen
Page 26 · click to enlarge
Page 26

Password Screen

Set Up Home Screen

If a password has been activated (see Configure Screen 1, page 29), the Password screen will appear. You must enter the password to access the Set Up Home Screen. Entering the wrong password returns the display to the Status Screen.

FIG. 20. Set Up Home Screen

This screen displays when you enter Setup mode. From it you can go to Recipe and Advanced Setup Screens (pages 34-42) or System Configuration Screens

(pages 28-31). Press the Enter key to go to the selected screen set.

FIG. 18. Password Screen

The screen also displays software versions and internet addresses of various components. The values shown in FIG. 20 are only examples and may vary on your screen. See Table 4 for further information.

ing to the Status Screen. A lock symbol appears

on the Status Screen.

FIG. 19. Setup Locked Screen

Setup Mode

Page 27 of the Graco Diaphragm Pump (312776F) user manual — Setup Mode
Page 27 · click to enlarge
Page 27
Table 4Component Software Versions

Display (may vary from examples shown) Description

EK (EasyKey) 3.01.001 EasyKey software version.

FP (Fluid Plate) 3.01.001 Fluid Plate software version.

BC (Booth Control) -.- Booth Control not installed, not detected, or not operational.

1.XX Booth Control software version 1.00 or 1.01.

2.XX Booth Control software version 2.XX.

C1/C2 (Color Change Modules 1 and 2)

-.- Color Change Module 1/2 not installed, not detected, or not operational.

1.XX Color Change Module software version 1.00 or 1.01.

2.XX Color Change Module software version 2.XX.

AK (Autokey) No Key No AutoKey installed or detected. System operates in 2K Manual Mode only

2K-Auto 2K AutoKey detected. System can operate in 2K Manual, Semi-automatic, or Automatic Mode.

3K-Auto 3K AutoKey detected. System can operate in 3K Manual, Semi-automatic, or Automatic Mode.

XP (XPORT) V6.6.0.2 Example of XPORT network module software version. Other versions are acceptable.

MC (Micro Controller) 1042.0198 Example of fluid plate micro controller version. Other versions are acceptable.

Axx By Cz A30 B4 Cx Color Change board valve configuration. This shows the num- ber of valves available for each of the components. This is set by the configuration switches on the color change boards connected to the system.

- Component not available with this machine configura- tion.

x Component not used with this machine configuration.

1 Component available but no change stack.

4-30 Component available with change stack. Number of valves flushed with a solvent valve.

IP (Internet Address) 192.168.178.3 Example of the address EasyKey is set to for basic and advanced web interface reporting.

MAC (MAC address) 00204AAD1810 Example of internet MAC address. Each EasyKey will have a different value in this format.

Setup Mode · Component · Code Description

Page 28 of the Graco Diaphragm Pump (312776F) user manual — System Configuration Screens
Page 28 · click to enlarge
Page 28

System Configuration Screens

Graco Diaphragm Pump (312776F) — System Configuration Screens diagram (page 28)
Fig. 42 · System Configuration Screens
Graco Diaphragm Pump (312776F) — System Configuration Screens diagram (page 28)
Fig. 43 · System Configuration Screens
Graco Diaphragm Pump (312776F) — System Configuration Screens diagram (page 28)
Fig. 44 · System Configuration Screens
Graco Diaphragm Pump (312776F) — System Configuration Screens diagram (page 28)
Fig. 45 · System Configuration Screens
Graco Diaphragm Pump (312776F) — System Configuration Screens diagram (page 28)
Fig. 46 · System Configuration Screens
Graco Diaphragm Pump (312776F) — System Configuration Screens diagram (page 28)
Fig. 47 · System Configuration Screens
Graco Diaphragm Pump (312776F) — System Configuration Screens diagram (page 28)
Fig. 48 · System Configuration Screens
Graco Diaphragm Pump (312776F) — System Configuration Screens diagram (page 28)
Fig. 49 · System Configuration Screens
Graco Diaphragm Pump (312776F) — System Configuration Screens diagram (page 28)
Fig. 50 · System Configuration Screens
Graco Diaphragm Pump (312776F) — System Configuration Screens diagram (page 28)
Fig. 51 · System Configuration Screens

FIG. 21. System Configuration and Option Screens Map

Setup Mode · TI12785a

Page 29 of the Graco Diaphragm Pump (312776F) user manual — Configure Screen 2
Page 29 · click to enlarge
Page 29

Configure Screen 1

Select the desired screen timeout in minutes (0-99). 5 is the default.

Configure Screen 2

FIG. 22. Configure Screen 1

Defines the language of the screen text. Select English (default), Spanish, French, German, Italian, Dutch, Jap- anese (Kanji), Korean, Chinese (Simplified), and Cus- tom.

FIG. 23. Configure Screen 2

Enter current month.

Enter current day.

The password is only used to enter Setup mode. The default is 0, which means no password is required to enter Setup. If a password is desired, enter a number from 1 to 9999.

Enter current year (four digits).

Enter current time in hours (24 hour clock), minutes, and seconds. Seconds are not adjustable.

Select MM-DD-YYYY, DD-MM-YYYY, or YYYY-MM-DD.

Select the desired display units:

  • cc/liter (default)
  • cc/gallon

As the default, the alarm buzzer is set to “Potlife Only” and will sound only for the Potlife Alarm (E-2).

Set to “All Alarms” to have the buzzer sound for any alarm.

Set to “All Except Potlife” to have the buzzer sound for any alarm except a Potlife Alarm (E2). This option is not recommended unless another active method of handling the Potlife Alarm is implemented.

Show 11 more labels / short text on this page
Setup Mode · Screen Timeout · Language · Month · Day · Password · Year · Time · Date Format · Display Units · Buzzer Alarms
Page 30 of the Graco Diaphragm Pump (312776F) user manual — 1K/2K/3K
Page 30 · click to enlarge
Page 30

Configure Screen 3

Configure Screen 4

FIG. 24. Configure Screen 3

FIG. 25. Configure Screen 4

1K/2K/3K

Set this value to indicate the system performance level designation. Selecting a value other than the installed system level will result in restricted functionality.

Enter the dose time (1 to 99 seconds). This is the amount of time allowed for a dose to occur before a dose time alarm occurs.

Select the total dose size (cc) from the pulldown menu: 100, 50, 25, 10, or select DD to turn on dynamic dosing (see page 48).

Indicates that this is a Manual system.

Example: For a total dose size of 50 cc and a ratio of 4.0:1, the component A dose size is 40 cc and component B dose size is 10 cc.

This field only appears if the color change option is detected from the cc board. Select “On” if an optional Dump Valve A is installed and desired to be used.

This field only appears if the catalyst change option is detected from the cc board, meaning that dump valve B is present. On is the only setting.

Enter the number of spray guns (1 or 2).

Off is default. If the system includes an optional 3rd flush valve, set to On.

Enter the number of gun flush boxes (Off, 1, or 2).

See Fig. 26 and Fig. 27 on page 31.

Show 10 more labels / short text on this page
Setup Mode · Dose Time Alarm · Run Mode · Dose Size · Dump Valve A · Dump Valve B · Number of Guns · 3rd Flush Valve · Gun Flush Box · DD Setup Mode
Page 31 of the Graco Diaphragm Pump (312776F) user manual — Configure Screen 5
Page 31 · click to enlarge
Page 31
Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 31)
Fig. 52 · Setup Mode

Use of Special Outputs on Manual systems requires installation of a Discrete I/O Integration Board. Order Graco Part No. 15V825 Discrete I/O Integration Board Kit. See manual 406800.

Select special outputs (0-4, or 3 + GFB on #4). A selec- tion of “0” will disable use of the Special Outputs. If the “3 + GFB on #4” selection is chosen, the other 3 special outputs (1-3) can be used for user-defined functions and the special output #4 settings will duplicate those set- tings established for the Gun Flush Box.

FIG. 26. Configure Screen 4, dynamic dosing selected

Graco Diaphragm Pump (312776F) — Setup Mode diagram (page 31)
Fig. 53 · Setup Mode

Each output has two different start times and durations defined on the Recipe Setup screen (Flush and Fill Input is set to “Recipe” in Option Screen 1, page 32), or on the Advanced Setup screen (Flush and Fill Input is set to “Global” in Option Screen 1, page 32).

Select solvent monitor (Off, Flow Switch, or Meter).

A selection of “Meter” will cause the system to track the amount of solvent used. See Totals Screen, page 23 for more information about solvent totals.

FIG. 27. Configure Screen 4, dynamic dosing setup mode enabled

The default web browser IP address prefix is 192.168.178.__ Assign a unique number for each EasyKey in your system (1-99) and enter it here.

Selecting “DD” in the Dose Size field makes the Dynamic Dosing setup mode field appear. Select On to enable DD setup mode, or Off to disable. See page 49 for further information.

Used for the Graco Gateway network system. See Graco Gateway manual 312785 for further information.

Configure Screen 5

FIG. 28. Configure Screen 5

Show 6 more labels / short text on this page
Setup Mode · Special Outputs · Solvent Monitor · Web Browser IP · DD Setup Mode · Control Network ID
Page 32 of the Graco Diaphragm Pump (312776F) user manual — Verification Screen
Page 32 · click to enlarge
Page 32

Option Screens

Minimum Material Fill Volume

Enter 0-9999 cc.

Verification Screen

Option Screen 1

FIG. 30. Verification Screen

FIG. 29. Option Screen 1

This screen appears if Flush and Fill Input or K-factor Input are changed from “Recipe” to “Global” in Option Screen 1.

This field only appears if Solvent Monitor is set to “Meter” in Configure Screen 5, page 31.

If set to “On”, Minimum Flush Volume will appear in Recipe Setup Screen 2, page 39.

Flush and Fill Input

If set to “Global”, Color/Catalyst Purge and Color/Cata- lyst Fill are added to Advanced Setup Screen 1, page 35. Advanced Setup Screen 2, 3, and 5 are added. See pages 35-37.

If set to “Recipe”, Color/Catalyst Purge and Color/Cata- lyst Fill are added to Recipe Setup Screen 2, page 39. Recipe Setup Screen 3, 4, and 7 are added. See pages 40-42.

Global mode is useful when the material properties, flush and fill characteristics, or K-factors are the same for all materials used by the system.

If set to “Global,” Advanced Setup Screen 4, page 36 is added.

If set to “Recipe,” Recipe Setup Screen 5, page 41, is added.

Show 4 more labels / short text on this page
Setup Mode · Verification · Flush Volume Check · K-factor Input
Page 33 of the Graco Diaphragm Pump (312776F) user manual — Option Screen 2
Page 33 · click to enlarge
Page 33

Option Screen 2

B Purge After Chop

Optional 2-second burst (2 s B) operation of the B Purge valve on the integrator after the Chop cycle.

See Color Change Sequences, page 67 for color change charts and timing information.

FIG. 31. Option Screen 2

If the auto dump feature is being used, set to “Solvent Push” or “Mix Fill Push”. Once the auto dump is enabled, the gun flush box is enabled and the potlife alarm is active for 2 minutes, the system will automati- cally flush or push out the old material based on the selected option.

“Solvent Push” will flush out expired material using the solvent supply. See Solvent Push Feature on page 63 for more information.

“Mix Fill Push” will push out expired material with new mixed material. When sufficient material has been pushed, the potlife alarm will reset. See Mix Fill Push Feature on page 64 for more information.

If set to “On,” Recipe Setup Screen 6 on page 41 is added, enabling setting of high and low flow limits.

If set to “Off,” flow rate monitoring is disabled and Rec- ipe Setup Screen 6 on page 41 will not appear.

To enable the Solvent Push feature, select “Solvent” or “3rd Valve” (available if 3rd Flush Valve in Configure Screen 3, page 30, is set to “On”).

To disable the Solvent Push feature, set to “Off.”

Show 4 more labels / short text on this page
Setup Mode · Auto Dump · Flow Rate Monitor · Solvent Push Enable
Page 34 of the Graco Diaphragm Pump (312776F) user manual — Advanced Setup Screens
Page 34 · click to enlarge
Page 34

Advanced Setup Screens

Graco Diaphragm Pump (312776F) — Advanced Setup Screens diagram (page 34)
Fig. 54 · Advanced Setup Screens
Graco Diaphragm Pump (312776F) — Advanced Setup Screens diagram (page 34)
Fig. 55 · Advanced Setup Screens

Advanced Setup screens 2, 3, 4, and 5 appear depending on selections made in Option

screens 1 and 2.

Graco Diaphragm Pump (312776F) — Advanced Setup Screens diagram (page 34)
Fig. 56 · Advanced Setup Screens
Graco Diaphragm Pump (312776F) — Advanced Setup Screens diagram (page 34)
Fig. 57 · Advanced Setup Screens
Graco Diaphragm Pump (312776F) — Advanced Setup Screens diagram (page 34)
Fig. 58 · Advanced Setup Screens
Graco Diaphragm Pump (312776F) — Advanced Setup Screens diagram (page 34)
Fig. 59 · Advanced Setup Screens
Graco Diaphragm Pump (312776F) — Advanced Setup Screens diagram (page 34)
Fig. 60 · Advanced Setup Screens
Graco Diaphragm Pump (312776F) — Advanced Setup Screens diagram (page 34)
Fig. 61 · Advanced Setup Screens
Graco Diaphragm Pump (312776F) — Advanced Setup Screens diagram (page 34)
Fig. 62 · Advanced Setup Screens
Graco Diaphragm Pump (312776F) — Advanced Setup Screens diagram (page 34)
Fig. 63 · Advanced Setup Screens
Graco Diaphragm Pump (312776F) — Advanced Setup Screens diagram (page 34)
Fig. 64 · Advanced Setup Screens
Graco Diaphragm Pump (312776F) — Advanced Setup Screens diagram (page 34)
Fig. 65 · Advanced Setup Screens

FIG. 32. Advanced Setup Screens Map

Setup Mode · TI12786a

Page 35 of the Graco Diaphragm Pump (312776F) user manual — Advanced Setup Screen 1
Page 35 · click to enlarge
Page 35

This field only appears if the system includes a color change module and Flush and Fill Input is set to “Global” in Option Screen 1, page 32. Enter the fill time (0 to 99 seconds). It refers to the time required to fill the lines from the color or catalyst module to the dose valve or dump valve.

Advanced Setup Screen 1

Advanced Setup Screen 2

FIG. 33. Advanced Setup Screen 1

FIG. 34. Advanced Setup Screen 2

Gun 1/Gun2 Potlife Volume

Enter the potlife volume (1 to 1999 cc) for each gun. This is the amount of material required to move through the mix manifold, hose and applicator/gun before the potlife timer is reset.

This screen appears only if Flush and Fill Input is set to “Global” in Option Screen 1, page 32.

Select “Air,” “Solvent,” or “3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30).

Use the following information to determine approximate pot life volume (PLV) in cc:

Hose ID (inches) Volume (cc/foot)*

3/16 5.43 1/4 9.648 3/8 21.71

Select “Air/Solvent” or “Air/3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30). This refers to the process of mix- ing air and solvent (or air and 3rd flush fluid) together during the flush cycle, to help clean the lines and reduce solvent usage.

Integrator manifold and mixer volume = 75 cc Spray Gun Volume = 20 cc

(Hose Volume* x Feet of Hose) + 75 + 20 = PLV

Select “Air,” “Solvent,” or “3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30).

This field only appears if the system includes a color change module and Flush and Fill Input is set to “Global” in Option Screen 1, page 32. Enter the purge time (0 to 99 seconds). It refers to the amount of time required to flush the lines from the color or catalyst mod- ule to the dose valve or dump valve.

Enter the air chop time (0.0 to 99.9 seconds).

Solvent Chop Time/3rd Flush Valve Chop Time

Enter the solvent or 3rd flush valve chop time (0.0 to 99.9 seconds).

Show 7 more labels / short text on this page
Setup Mode · Color/Catalyst Fill · First Purge Source · Chop Type · Final Purge Source · Color/Catalyst Purge · Air Chop Time
Page 36 of the Graco Diaphragm Pump (312776F) user manual — Advanced Setup Screen 3
Page 36 · click to enlarge
Page 36

Advanced Setup Screen 3

Advanced Setup Screen 4

FIG. 35. Advanced Setup Screen 3

FIG. 36. Advanced Setup Screen 4

This screen appears only if Flush and Fill Input is set to “Global” in Option Screen 1, page 32.

This screen appears only if K-factor Input is set to “Global” in Option Screen 1, page 32.

If Number of Guns is set to “2” in Configure Screen 4, page 30, a Gun 2 column will appear in this screen.

Enter the k-factor (cc/pulse) for flow meter A. This is the amount of material that passes through the flow meter per pulse (electrical pulse signal).

Enter the first purge time (0 to 999 seconds).

Enter the k-factor (cc/pulse) for flow meter B.

Enter the total chop time (0 to 999 seconds).

This field only appears if Solvent Monitor in Configure Screen 5, page 31, is set to “Meter.” Enter the k-factor (cc/pulse) for the solvent flow meter.

Enter the final purge time (0 to 999 seconds).

Mixed Material Fill Time

Enter the mixed material fill time (0 to 999 seconds). It refers to the amount of time that is required to load mixed material from the dose valves to the applica- tor/gun.

Show 7 more labels / short text on this page
Setup Mode · K-factor A Meter · First Purge Time · K-factor B Meter · Total Chop Time · K-factor Solvent Meter · Final Purge Time
Page 37 of the Graco Diaphragm Pump (312776F) user manual — Advanced Setup Screen 5
Page 37 · click to enlarge
Page 37

Advanced Setup Screen 5

FIG. 37. Advanced Setup Screen 5

This screen appears only if Flush and Fill Input is set to “Global” in Option Screen 1, page 32 and Special Out- puts is set to 1, 2, 3, or 4 in Configure Screen 5, page 31. The I/O board has four programmable outputs.

Delay time at the start of the purge cycle before the Spe- cial Output turns on.

Duration for the Special Output to be active during the purge cycle.

Delay time at the start of the fill cycle before the Special Output turns on.

Duration for the Special Output to be active during the fill cycle.

Show 5 more labels / short text on this page
Setup Mode · On-Purge · Length · On-Fill · Length
Page 38 of the Graco Diaphragm Pump (312776F) user manual — Recipe Setup Screens
Page 38 · click to enlarge
Page 38

Recipe Setup Screens

Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 66 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 67 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 68 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 69 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 70 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 71 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 72 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 73 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 74 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 75 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 76 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 77 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 78 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 79 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 80 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 81 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 82 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 83 · Recipe Setup Screens
Graco Diaphragm Pump (312776F) — Recipe Setup Screens diagram (page 38)
Fig. 84 · Recipe Setup Screens

Recipe screens 3, 4, 5, 6, and

7 appear depending on selections made in Option

screens 1 and 2

F IG . 38Recipe Screens Map

Setup Mode · Recipe 0 Screens · TI12787a

Page 39 of the Graco Diaphragm Pump (312776F) user manual — Recipe Setup Screen 1
Page 39 · click to enlarge
Page 39

Recipe Setup Screen 2

Recipe Setup Screen 1

FIG. 40. Recipe Setup Screen 2

Minimum Flush Volume This field only appears if Flush Volume Check is set to “On” in Option Screen 1 on page 32. Enter the mini- mum flush volume (0 to 9999 cc). Entering 0 disables this function.

FIG. 39. Recipe Setup Screen 1

Potlife Time Enter the potlife time (0 to 999 minutes). Entering 0 dis- ables this function.

Enter the mix ratio of component A over component B (0.0:1 to 50:1).

This field only appears if the system includes a color change module and Flush and Fill Input is set to “Rec- ipe” in Option Screen 1, page 32. Enter the purge time (0 to 99 seconds). It refers to the amount of time required to flush the lines from the color or catalyst mod- ule to the dose valve or dump valve.

Enter the ratio tolerance (1 to 99%). This refers to the percent of acceptable variance that the system will allow before a ratio alarm occurs.

Component A (Color) Valve (if present)

This field only appears if the system includes a color change module. Enter the color valve number (1 to 30).

This field only appears if the system includes a color change module and Flush and Fill Input is set to “Rec- ipe” in Option Screen 1, page 32. Enter the fill time (0 to 99 seconds). It refers to the time required to fill the lines from the color or catalyst module to the dose valve or dump valve.

Component B (Catalyst) Valve (if present)

This field only appears if the system includes a color change module. Enter the catalyst valve number (1 to 4).

Show 5 more labels / short text on this page
Setup Mode · Ratio · Color/Catalyst Purge · Ratio Tolerance · Color/Catalyst Fill
Page 40 of the Graco Diaphragm Pump (312776F) user manual — Recipe Setup Screen 3
Page 40 · click to enlarge
Page 40

Recipe Setup Screen 3

Recipe Setup Screen 4

FIG. 41. Recipe Setup Screen 3

FIG. 42. Recipe Setup Screen 4

This screen appears only if Flush and Fill Input is set to “Recipe” in Option Screen 1, page 32.

This screen appears only if Flush and Fill Input is set to “Recipe” in Option Screen 1, page 32.

If Number of Guns is set to “2” in Configure Screen 4, page 30, a Gun 2 column will appear in this screen.

Select “Air,” “Solvent,” or “3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30).

Enter the first purge time (0 to 999 seconds).

Select “Air/Solvent” or “Air/3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30). This refers to the process of mix- ing air and solvent (or air and 3rd flush fluid) together during the flush cycle, to help clean the lines and reduce solvent usage.

Enter the total chop time (0 to 999 seconds).

Enter the final purge time (0 to 999 seconds).

Mixed Material Fill Time

Enter the mixed material fill time (0 to 999 seconds). It refers to the amount of time that is required to load mixed material from the dose valves to the applica- tor/gun.

Select “Air,” “Solvent,” or “3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30.)

Enter the air chop time (0.0 to 99.9 seconds).

Solvent Chop Time/3rd Flush Valve Chop Time

Enter the solvent or 3rd flush valve chop time (0.0 to 99.9 seconds).

Show 8 more labels / short text on this page
Setup Mode · First Purge Source · First Purge Time · Chop Type · Total Chop Time · Final Purge Time · Final Purge Source · Air Chop Time
Page 41 of the Graco Diaphragm Pump (312776F) user manual — Recipe Setup Screen 5
Page 41 · click to enlarge
Page 41

Recipe Setup Screen 5

Recipe Setup Screen 6

FIG. 43. Recipe Setup Screen 5

FIG. 44. Recipe Setup Screen 6

This screen appears only if K-factor Input is set to “Rec- ipe” in Option Screen 1, page 32.

This screen appears only if Flow Rate Monitor is set to “On” in Option Screen 2 on page 33.

Enter the k-factor (cc/pulse) for flow meter A. This is the amount of material that passes through the flow meter per pulse (electrical pulse signal).

Select the desired flow rate monitoring (Off, Warning, or Alarm).

Enter the low flow rate limit (1 to 3999 cc/min).

Enter the k-factor (cc/pulse) for flow meter B.

Enter the high flow rate limit (1 to 3999 cc/min).

This field only appears if Solvent Monitor in Configure Screen 5, page 31, is set to “Meter.” Enter the k-factor (cc/pulse) for the solvent flow meter.

Show 7 more labels / short text on this page
Setup Mode · K-factor A Meter · Flow Rate Monitor · Low Flow Limit · K-factor B Meter · High Flow Limit · K-factor Solvent Meter
Page 42 of the Graco Diaphragm Pump (312776F) user manual — Recipe Setup Screen 7
Page 42 · click to enlarge
Page 42

Recipe Setup Screen 7

FIG. 45. Recipe Screen 7

This screen appears only if Flush and Fill Input is set to “Recipe” in Option Screen 1, page 32 and Special Out- puts is set to 1, 2, 3, 4, or “3 + GFB on #4” in Configure Screen 5, page 31. The I/O board has four programma- ble outputs.

Delay time at the start of the purge cycle before the Spe- cial Output turns on.

Duration for the Special Output to be active during the purge cycle.

Delay time at the start of the fill cycle before the Special Output turns on.

Duration for the Special Output to be active during the fill cycle.

Show 5 more labels / short text on this page
Setup Mode · On-Purge · Length · On-Fill · Length
Page 43 of the Graco Diaphragm Pump (312776F) user manual — Recipe 0 Screen 1
Page 43 · click to enlarge
Page 43

Recipe 0 Screens

Enter the air chop time (0.0 to 99.9 seconds).

Solvent Chop Time/3rd Flush Valve Chop Time

  • Recipe 0 is typically used:
  • in multiple color systems to purge out material lines without loading a new color
  • at the end of a shift to prevent hardening of catalyzed material.

Enter the solvent or 3rd flush valve chop time (0.0 to 99.9 seconds).

Recipe 0 Screen 2

Recipe 0 Screen 1

FIG. 47. Recipe 0 Screen 2

If Number of Guns is set to “2” in Configure Screen 4, page 30, a Gun 2 column will appear in this screen.

This field only appears if the system includes a color change module. It refers to the amount of time required to flush the lines from the color or catalyst module to the dose valve or dump valve. Enter the purge time (0 to 999 seconds).

FIG. 46. Recipe 0 Screen 1

Enter the first purge time (0 to 999 seconds).

Select “Air,” “Solvent,” or “3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30).

Enter the total chop time (0 to 999 seconds).

Select “Air/Solvent” or “Air/3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30). This refers to the process of mix- ing air and solvent (or air and 3rd flush fluid) together during the flush cycle, to help clean the lines and reduce solvent usage.

Enter the final purge time (0 to 999 seconds).

Select “Air,” “Solvent,” or “3rd Flush Valve” (available only if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30.)

Show 9 more labels / short text on this page
Setup Mode · Air Chop Time · Color/Catalyst Purge Time · First Purge Time · First Purge Source · Total Chop Time · Chop Type · Final Purge Time · Final Purge Source
Page 44 of the Graco Diaphragm Pump (312776F) user manual — Recipe 0 Screen 3
Page 44 · click to enlarge
Page 44

Recipe 0 Screen 3

Recipe 0 Screen 4

FIG. 48. Recipe 0 Screen 3

FIG. 49. Recipe 0 Screen 4

This screen only appears if Solvent Monitor is set to “Meter” in Configure Screen 5, page 31 and Flush Vol- ume Check is set to “On” in Option Screen 1, page 32 or 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30.

This screen appears only if Flush and Fill Input is set to “Recipe” in Option Screen 1, page 32 and Special Out- puts is set to 1, 2, 3, 4, or “3 + GFB on #4” in Configure Screen 5, page 31. The I/O board has four programma- ble outputs.

Minimum Flush Volume This field only appears if Flush Volume Check is set to “On” in Option Screen 1 on page 32. Enter the mini- mum flush volume (0 to 9999 cc).

Exiting Fill Source This field only appears if 3rd Flush Valve is set to “On” in Configure Screen 3 on page 30. Select “Off,” “Air,” “Solvent,” or “3rd Valve.”

Delay time at the start of the purge cycle before the Spe- cial Output turns on.

Duration for the Special Output to be active during the purge cycle.

Delay time at the start of the fill cycle before the Special Output turns on.

Duration for the Special Output to be active during the fill cycle.

Show 5 more labels / short text on this page
Setup Mode · On-Purge · Length · On-Fill · Length
Page 45 of the Graco Diaphragm Pump (312776F) user manual — Calibration Screen
Page 45 · click to enlarge
Page 45

Calibration Screen

FIG. 50. Calibration Screen

Use this screen to calibrate a meter. Set to “A Meter,” “B Meter,” or “Solvent Meter” (available if Solvent Monitor in Configure Screen 5, page 31, is set to “Meter”).

  • Start - start calibration
  • Abort - stop calibration
  • Purge - purge sampling valves after calibration

See Meter Calibration, page 65, for when and how to calibrate a meter.

Setup Mode

Page 46 of the Graco Diaphragm Pump (312776F) user manual — Mix Fill Push
Page 46 · click to enlarge
Page 46

System Operation

Operation Modes

General Operating Cycle, Sequential Dosing

Mix

1. The spray gun operator enters and loads the desired recipe. The color change LED blinks while recipe is loading, then turns solid when complete.

System mixes and dispenses material.

2. The operator presses the Mix key to begin operation.

Standby

Stops the system.

3. The ProMix 2KS controller sends signals to activate the solenoid valves. The solenoid valves activate Dose Valves A and B. Fluid flow begins when the gun is triggered.

Purge

Purges the system, using air and solvent.

4. Components A and B are introduced into the fluid integrator (FI) one at a time as follows.

Sequential Dosing

a. Dose Valve A (DVA) opens, and fluid flows into the integrator.

Components A and B dispense sequentially in the nec- essary volumes to attain the mix ratio.

b. Flow Meter A (MA) monitors the fluid volume dispensed and sends electrical pulses to the ProMix 2KS controller. The controller monitors these pulses and signals.

Dynamic Dosing

In typical operation (ratios 1:1 and above), component A dispenses constantly. Component B dispenses intermit- tently in the necessary volume to attain the mix ratio.

c. When the target volume dispenses, Dose Valve A closes.

Recipe (Color) Change

The process when the system automatically flushes out the old color and loads a new color.

d. Dose Valve B (DVB) opens, and fluid flows into the integrator and is aligned proportionately with component A.

Solvent Push

e. Flow Meter B (MB) monitors the fluid volume dispensed and sends electrical pulses to the ProMix 2KS controller.

The Solvent Push feature enables the user to save some mixed material by pushing it out to the gun with solvent. The feature requires an accessory solvent meter. See page 63 for complete information.

f. When the target volume is dispensed, Dose Valve B closes.

Mix Fill Push

The Mix Fill Push feature enables the user to prevent potlife expiration of material by mixing and flowing new material through the Gun Flush Box. See page 64 for complete information.

System Operation

Page 47 of the Graco Diaphragm Pump (312776F) user manual — A = 2
Page 47 · click to enlarge
Page 47
5. The components are pre-mixed in the integrator, then uniformly blended in the static mixer (SM).
7. If the gun is not triggered for two minutes, the system switches to Idle mode, which closes off the mix manifold dose valves.
8. When the gun is triggered again, the ProMix 2KS continues the process where it left off.
6. Components A and B are alternately fed into the integrator as long as the gun is triggered.

pressing the Standby key or shutting off the

main power switch.

Table 5Sequential Dosing Operation

Ratio = 2.0:1 Dose 1 Dose 2 Dose 3

A = 2

B = 1

DVA

FI

MB DVB

MS

MA

RVB

AT

APV

RVA

SVA SVB

SM

SPV

Key: MA Component A Meter DVA Component A Dose Valve RVA Component A Sampling Valve SVA Component A Shutoff Valve MB Component B Meter DVB Component B Dose Valve RVB Component B Sampling Valve

SVB Component B Shutoff Valve MS Solvent Meter (accessory) SPV Solvent Purge Valve APV Air Purge Valve SM Static Mixer FI Fluid Integrator AT Air Purge Valve Air Supply Tube

FIG. 51. Wall Mount Fluid Station, Sequential Dosing

System Operation · TI12556b

Page 48 of the Graco Diaphragm Pump (312776F) user manual — Overview
Page 48 · click to enlarge
Page 48

General Operating Cycle, Dynamic Dosing

Overview

Dynamic Dosing System Parameters

Dynamic Dosing provides on-demand proportioning, eliminating the need for an integrator and therefore min- imizing undesired material contact. This feature is espe- cially useful with shear-sensitive and waterborne materials.

The following parameters affect dynamic dosing perfor- mance:

  • Component A Flow: Ensure that the supply pump is sized to provide sufficient and uninterrupted flow. Note that component A provides majority of system flow at higher mix ratios.

A restrictor injects component B into a continuous stream of component A. The software controls the dura- tion and frequency of each injection. See FIG. 52 for a schematic diagram of the process.

  • Component B Flow: Ensure that the supply pump is sized to provide sufficient and uninterrupted flow.
  • Component A Pressure: Ensure precise pressure regulation. It is recommended that the component A pressure be 5-15% lower than the component B pressure.
  • Component B Pressure: Ensure precise pressure regulation. It is recommended that the component B pressure be 5-15% higher than the component A pressure.

Component A (continuous flow) Proportioned Material

Component B (pulsed injection)

FIG. 52. Schematic Diagram of Dynamic Dosing Operation

System Operation · To Static · Mixer

Page 49 of the Graco Diaphragm Pump (312776F) user manual — Turn On Dynamic Dosing
Page 49 · click to enlarge
Page 49

Select a Component B Restrictor Size

3. Selecting “DD” in System Configure Screen 4 makes the DD Setup mode available. See F IG . 55. To enable DD setup mode, select On in the DD setup mode drop down menu. This disables Off Ratio alarms E-3 and E-4, allowing uninterrupted setup and tuning.

Install the 15U955 Injection Kit in the fluid manifold as explained in the ProMix 2KS Installation manual. Use the charts provided in that manual to select an appropri- ate restrictor size based on the desired flow and mix ratio.

Turn On Dynamic Dosing

1. On the EasyKey press the Setup key to access

the Set Up Home screen. Select “System Configu- ration” to access the configuration screens. FIG. 53.

FIG. 53. Set Up Home Screen

FIG. 55. Configure Screen 4, dynamic dosing setup mode enabled

2. Navigate to System Configure Screen 4. Select “DD” option from the “Dose Size” drop down menu. F IG . 54.

FIG. 54. Configure Screen 4, dynamic dosing selected

System Operation

Page 50 of the Graco Diaphragm Pump (312776F) user manual — Balancing A/B Pressure
Page 50 · click to enlarge
Page 50

Balancing A/B Pressure

If component B pressure is too high, it will push the com- ponent A stream aside during B injection. The valve will not open long enough, causing a High Ratio alarm.

B Pressure Too Low

If component B pressure is too low, it will not be injected in sufficient volume. The valve will stay open too long, causing a Low Ratio alarm.

Selecting the correct component B restrictor size and balancing the A/B pressures will keep the system in the proper pressure range, resulting in a consistent mix ratio.

A Pressure B Pressure

FIG. 57. A/B Control Range with Properly Sized Restrictor

FIG. 57 shows the A to B pressure balance, read at the proportioner inlet. It is recommended that the compo- nent B pressure be 5-15% higher than the component A pressure to keep the system in the control range, hold the proper mix ratio, and obtain properly mixed material. If pressures are not balanced (“B Pressure Too High” or “B Pressure Too Low”), it may not be possible to hold the desired mix ratio. The system will generate an off ratio alarm and stop operation.

B Pressure Too Low

A Pressure B Pressure

In dynamic dosing, component A dose valve is con- stantly on. Component B dose valve will cycle on and off; one cycle every 0.5 – 1.0 seconds indicates proper balance.

FIG. 58. A/B Control Range with Too Large a Restrictor

Monitor system performance by watching the EasyKey display for warning messages which provide information on system performance, and adjust pressures accord- ingly. See Table 6 on page 51.

Graco Diaphragm Pump (312776F) — Balancing A/B Pressure diagram (page 50)
Fig. 85 · Balancing A/B Pressure

FIG. 56. B Pressure Too Low, displayed on EasyKey

Show 8 more labels / short text on this page
System Operation · Control Range · B Pressure · Too High · Control Range · (too small) · B Pressure · Too High
Page 51 of the Graco Diaphragm Pump (312776F) user manual — E
Page 51 · click to enlarge
Page 51

Table 6: Dynamic Dosing Troubleshooting Guide (for complete system troubleshooting, see Table 11 beginning on page 81)

  • B Pressure Too Low (see F IG . 56)
  • Increase B pressure.
  • Clean restrictor or use a larger size.
  • Verify B valve is opening properly.
  • B Pressure Too High
  • Increase A pressure or decrease B pressure.
  • Use a smaller restrictor.
  • Off Ratio Low
  • Increase A pressure or decrease B pressure.
  • Use a smaller restrictor.
  • Off Ratio High
  • Increase B pressure.
  • Clean restrictor or use a larger size.
  • Verify B valve is opening properly.

Mix Manifold Valve Settings

To open dose or purge valves, turn hex nut (E) counter- clockwise. To close, turn clockwise. See Table 7 and FIG. 59.

Graco Diaphragm Pump (312776F) — Mix Manifold Valve Settings diagram (page 51)
Fig. 86 · Mix Manifold Valve Settings

E

FIG. 59. Valve Adjustment

Table 7Mix Manifold Valve Settings

Dose (FIG. 59)

Hex nut (E) 1-1/4 turns out from fully closed

Limits maximum fluid flow rate into integrator and minimizes valve response time.

Purge (FIG. 59)

Hex nut (E) 1-1/4 turns out from fully closed

Limits maximum fluid flow rate into integrator and minimizes valve response time.

Shutoff (SVA and SVB, FIG. 67)

Fully open during Run/Mix operation

Closes component A and B ports to integrator during ratio check or meter calibration. Open ports during Run/Mix operation.

Sampling (RVA and RVB, FIG. 67)

Fully closed during Run/Mix operation

Open to dispense component A and B while calibrating meters. Do not open sampling valves unless fluid shutoff valves are closed.

System Operation · TI11581a · Valve Setting Function

Page 52 of the Graco Diaphragm Pump (312776F) user manual — System Idle Warning (E-15)
Page 52 · click to enlarge
Page 52

Air Flow Switch (AFS) Function

Operating Without Air Flow Switch

It is not recommended to run without an air flow switch. If a switch fails, replace it as soon as possible.

Air or Air-assisted Guns

The air flow switch (AFS) detects air flow to the gun and signals the ProMix controller when the gun is triggered. The AFS functions with the flow meters to ensure that system components are functioning correctly.

Airless Gun

It is not recommended to use an airless gun with the ProMix 2KS. Two issues can arise from operating with- out an air flow switch:

For example, if a flow meter fails or clogs, pure resin or catalyst could spray indefinitely if the ProMix does not detect the condition and intervene, which is why the AFS is so important.

  • Without a gun trigger/air flow switch input the ProMix 2KS does not know it is spraying and will not generate a Dose Time Alarm (E-7 or E-8). This means there is no way to detect a failed meter. You could spray pure resin or catalyst for 2 minutes without knowing.

If the ProMix detects through the AFS signal that the gun is triggered, yet there is no fluid flow through the meter, a Dose Time Alarm (E-7 or E-8) occurs after 40 seconds and the system shuts down.

  • Since the ProMix 2KS does not know it is spraying because there is no gun trigger/air flow switch input, it will go into System Idle (E-15) every 2 minutes when in Mix mode.
Graco Diaphragm Pump (312776F) — Airless Gun diagram (page 52)
Fig. 87 · Airless Gun

System Idle Warning (E-15)

AFS

This warning occurs if the ProMix is set to Mix , and 2 minutes have elapsed since the system received a flow meter pulse.

In applications using the AFS, triggering the gun clears the warning and you can start spraying again.

F IG . 60Air Flow Switches

Without the AFS, triggering the gun does not clear the alarm. To start spraying again, you must press Standby

, then Mix , then trigger the gun.

System Operation · TI13350a

Page 53 of the Graco Diaphragm Pump (312776F) user manual — I = ON
Page 53 · click to enlarge
Page 53

Start Up

1. Go through the Pre-Operation Checklist in Table 8.

Graco logo, software revision, and “Establishing

Communication” will display, followed by Status screen. See page 20. At power up the system defaults to Recipe 61,

Table 8Pre-Operation Checklist

which is not a valid recipe number. Initiate a color change to Recipe 0 or a valid recipe num- ber (1-60). In bottom left corner, the system status dis-

Verify all grounding connections were made. See the Installation manual.

plays, which can be Standby, Mix, Purge, or an alarm notification

All connections tight and correct

Verify all electrical, fluid, air, and system connec- tions are tight and installed according to the Installation manual.

Check air purge valve tubing

Check the air purge valve supply tube daily for any visible solvent accumulation. Notify your supervisor if solvent is present.

Fluid supply containers filled

Check component A and B and solvent supply containers.

Mix manifold valves set

Check that mix manifold valves are set correctly. Start with the settings recommended in Mix Mani- fold Valve Settings, page 51, then adjust as needed.

FIG. 62. Status Screen

3. Make sure that the Booth Control is working. The active recipe number should display and the

Fluid supply valves open and pressure set

Component A and B fluid supply pressures should be equal unless one component is more viscous and requires a higher pressure setting.

Standby LED should be lit.

4. If this is the first time starting up the system, purge it as instructed in Purging Fluid Supply System , page 60. The equipment was tested with lightweight oil, which should be flushed out to avoid contaminating your material.

75-100 psi inlet air supply (0.5-0.7 MPa, 5.2-7 bar)

2. Turn the AC Power Switch ON (I = ON, 0 = OFF).
5. Make sure that the Booth Control is in Standby
Graco Diaphragm Pump (312776F) — Start Up diagram (page 53)
Fig. 88 · Start Up

mode.

I = ON

FIG. 61. Power Switch

Show 5 more labels / short text on this page
System Operation · Checklist · System grounded · Solenoid pressure set · TI12656a
Page 54 of the Graco Diaphragm Pump (312776F) user manual — System Operation
Page 54 · click to enlarge
Page 54
6. Adjust component A and B fluid supplies as needed for your application. Use lowest pressure possible.

Watch the fluid flow rate displayed on the Status screen while the gun is fully open. Verify that the flow rate of components A and B are within 10% of each other.

7. Do not exceed the maximum rated working pressure shown on the system identification label or the lowest rated component in the system.

If the fluid flow rate is too low: increase air pres- sure to component A and B fluid supplies or increase the regulated fluid pressure.

8. Open the fluid supply valves to the system.

If the fluid flow rate is too high: reduce the air pressure, close the fluid manifold dose valves fur- ther, or adjust the fluid pressure regulator.

9. Adjust the air pressure. Most applications require about 80 psi (552 kPa, 5.5 bar) air pressure to operate properly. Do not use less than 75 psi (517 kPa, 5.2 bar).
10. If using a gun flush box, place the gun into the box

and close the lid. Press the Purge key on the

Booth Control. The purge sequence automatically starts.

12. Turn on atomizing air to the gun. Check the spray pattern as instructed in your spray gun manual.

If the gun flush box is not used, trig- ger the gun into a grounded metal pail until the purge sequence is com- plete.

NOTE: Do not allow a fluid supply tank to run empty. It is possible for air flow in the supply line to turn gear meters in the same manner as fluid. This can lead to the proportioning of fluid and air that meets the ratio and tol- erance settings of the equipment. This can further result in spraying uncatalyzed or poorly catalyzed material.

When done purging, the Booth Control automati- cally switches to Standby mode.

11. Adjust the flow rate.

The fluid flow rate shown on the EasyKey Status screen is for either component A or B, depending on which dose valve is open. The fluid supply lines on the screen highlight to show which dose valve is open.

FIG. 63. Status Screen Flow Rate Display

System Operation

Page 55 of the Graco Diaphragm Pump (312776F) user manual — 0 = OFF
Page 55 · click to enlarge
Page 55

Shutdown

Pressure Relief Procedure

Overnight Shutdown

1. Leave the power on.
2. Run Recipe 0 to purge solvent through meters and gun.

Service Shutdown

Relieve pressure when you stop spraying, before changing spray tips, and before cleaning, checking, or servicing equipment.

1. Follow Pressure Relief Procedure on page 55.
2. Close main air shutoff valve on air supply line and on ProMix.

Single Color Systems

3. Shut off ProMix 2KS power (0 position). F IG . 64.
1. While in Mix mode (gun triggered), shut off the A and B fluid supply pumps/pressure pots. Close all fluid shutoff valves at the pump outlets.
4. If servicing EasyKey, also shut off power at main circuit breaker.
2. With the gun triggered, push the manual override on the A and B dose valve solenoids to relieve pressure. See F IG . 65.

0 = OFF

3. Do a complete system purge, following the instructions under Purging Using Recipe 0 , page 60.
4. Shut off the fluid supply to the solvent purge valve (SPV) and the air supply to the air purge valve (APV), F IG . 67.

FIG. 64. Power Switch

5. With the gun triggered, push the manual override on the A and B purge valve solenoids to relieve air and solvent pressure. See F IG . 65. Verify that solvent pressure is reduced to 0.

System Operation · TI12657a

Page 56 of the Graco Diaphragm Pump (312776F) user manual — Systems with Color Change and without Dump Valves
Page 56 · click to enlarge
Page 56

Systems with Color Change and without Dump Valves

Systems with Color/Catalyst Change and Dump Valves

1. Complete all steps under Single Color Systems , page 55.
1. Complete all steps under Single Color Systems , page 55.
2. Close the A side shutoff valve (SVA), F IG . 67. Open the A side sampling valve (RVA).
2. Shut off all color and catalyst supplies to the valve stacks.
3. Direct the A side sampling tube into a waste container.
3. Press and hold the dump valve A solenoid override, F IG . 65.
4. See F IG . 66. Open the color change module. Using the solenoid identification labels as a guide, press and hold the override button on each color solenoid until flow from the sampling valve stops.
4. See F IG . 66. Open the color change module. Using the solenoid identification labels as a guide, press and hold the override button on each color solenoid until flow from dump valve A stops.
5. Press and hold the solvent solenoid override until clean solvent comes from the sampling valve, then release.
5. Press and hold the dump valve B solenoid override, F IG . 65.
6. See F IG . 66. Using the solenoid identification labels as a guide, press and hold the override button on each catalyst solenoid until flow from dump valve B stops.
6. Shutoff the solvent supply to the color change stack solvent valve.
7. Press and hold the solvent solenoid override until solvent flow from the sampling valve stops.
7. Press and hold the dump valve A solenoid override, F IG . 65.
8. Open the A side shutoff valve (SVA), F IG . 67. Close the A side sampling valve (RVA).
8. Press and hold the A side (color) solvent solenoid override until clean solvent comes from the dump valve, then release.
9. Press and hold the dump valve B solenoid override, F IG . 65.
10. Press and hold the B side (catalyst) solvent solenoid override until clean solvent comes from the dump valve, then release.
11. Shutoff the solvent supply to the color/catalyst change stack solvent valves.
12. Press and hold the A and B solvent solenoid overrides and dump valve overrides until solvent flow from the dump valves stops.

System Operation

Page 57 of the Graco Diaphragm Pump (312776F) user manual — J9
Page 57 · click to enlarge
Page 57
Graco Diaphragm Pump (312776F) — System Operation diagram (page 57)
Fig. 89 · System Operation

F2 F1

J1

CAN

J13

CAN

J12

J3

Dose A Dose B

J9

GFB 2

GFB 1

J14 J15 J8

GFB 1

GFB 2

3rd Purge Valve Solenoid

Purge Valve B Solenoid Purge Valve A Solenoid Dose Valve B

FIG. 65. Fluid Solenoids

Show 17 more labels / short text on this page
System Operation · Power · Fiber Optic · Valve · 3rd Purge · Purge A · Purge B · Dump A · Dump B · Dump Valve A · Dump Valve B · Optional Solenoid · Locations · Dose Valve A · Solenoid · Solenoid · TI12652b
Page 58 of the Graco Diaphragm Pump (312776F) user manual — AT
Page 58 · click to enlarge
Page 58
Graco Diaphragm Pump (312776F) — System Operation diagram (page 58)
Fig. 90 · System Operation
F IG . 66Color Change Solenoids
KeyMA Component A Meter DVA Component A

DVA

FI

MB DVB

Graco Diaphragm Pump (312776F) — DVA diagram (page 58)
Fig. 91

Dose Valve RVA Component A

MS

Sampling Valve SVA Component A

Shutoff Valve MB Component B Meter DVB Component B

RVB

Dose Valve RVB Component B

Sampling Valve SVB Component B

Shutoff Valve MS Solvent Meter SPV Solvent Purge Valve APV Air Purge Valve SM Static Mixer FI Fluid Integrator AT Air Purge Valve Air Supply Tube

AT

APV

RVA

SVA SVB

SM

SPV

FIG. 67. Wall Mount Fluid Station

Show 7 more labels / short text on this page
System Operation · Solenoid Identification · Solenoid Identification Label · Label · TI12826a · Solvent Solenoid Overrides · TI12556b
Page 59 of the Graco Diaphragm Pump (312776F) user manual — Purging Mixed Material
Page 59 · click to enlarge
Page 59

Purging

If using an electrostatic gun shut off the electrostatics before flushing the gun.

Read Warnings, page 7. Follow the Grounding instructions in your system Installation manual.

To avoid splashing fluid in the eyes, wear eye protec- tion.

2. Set the solvent supply pressure regulator at a pressure high enough to completely purge the system in a reasonable amount of time but low enough to avoid splashing or an injection injury. Generally, a setting of 100 psi (0.7 MPa, 7 bar) is sufficient.

There are 4 purging procedures in this manual:

  • Purging Mixed Material (below)
  • Purging Using Recipe 0 (page 60)
  • Purging Fluid Supply System (page 60)
  • Purging Sampling Valves and Tubes (page 62)
3. If using a gun flush box, place the gun into the box

and close the lid. Press the Purge key on the

Booth Control. The purge sequence automatically starts.

Use the criteria listed in each procedure to determine which procedure to use.

If the gun flush box is not used, trig- ger the gun into a grounded metal pail until the purge sequence is com- plete.

Purging Mixed Material

There are times when you only want to purge the fluid manifold, such as:

  • end of potlife
  • breaks in spraying that exceed the potlife
  • overnight shutdown
  • before servicing the fluid manifold assembly, hose or gun.

When done purging, the Booth Control automati- cally switches to Standby mode.

4. If the system is not completely clean, repeat step 3.

Solvent purges the component B (catalyst, right) side of the mix manifold and the inner tube of the integrator. Air purges the component A (resin, left) side and the outer tube of the integrator.

Trigger the gun to relieve pressure. Engage trigger lock.

1. Press the Standby key on the Booth Control.
5. If spray tip was removed, reinstall it.
6. Adjust the solvent supply regulator back to its normal operating pressure.

Trigger the gun to relieve pressure.

If you are using a high pressure gun, engage the trig- ger lock. Remove spray tip and clean tip separately.

System Operation

Page 60 of the Graco Diaphragm Pump (312776F) user manual — Purging Using Recipe 0
Page 60 · click to enlarge
Page 60

Purging Using Recipe 0

Purging Fluid Supply System

  • Recipe 0 is typically used:
  • in multiple color systems to purge out material lines without loading a new color
  • at the end of a shift to prevent hardening of catalyzed material.
  • Follow this procedure before:
  • the first time material is loaded into equipment*
  • servicing
  • shutting down equipment for an extended period of time
  • putting equipment into storage

To setup Recipe 0, go to Advanced Setup. Select the Recipe tab and change the Recipe to 0. The Recipe 0 Setup Screen appears. Set the chop times from 0-999 seconds in increments of 1 second.

* Some steps are not necessary for initial flushing, as no material has been loaded into the system yet.

1. Press the Standby key on the Booth Control.
1. Press the Standby key on the Booth Control.

Trigger the gun to relieve pressure.

Trigger the gun to relieve pressure.

If you are using a high pressure gun, engage the trig- ger lock. Remove spray tip and clean tip separately.

If you are using a high pressure gun, engage the trig- ger lock. Remove spray tip and clean tip separately.

If using an electrostatic gun, shut off the electrostatics before flushing the gun.

If using an electrostatic gun shut off the electrostatics before flushing the gun.

2. Attach solvent supply lines as follows:
2. If using a gun flush box, place the gun into the box and close the lid.
  • Single color/single catalyst systems: disconnect the component A and B fluid supplies at the flow meter inlets, and connect regulated solvent supply lines.
3. Select Recipe 0 and press Enter .
4. If a gun flush box is not used, trigger the gun into a grounded metal pail until the purge sequence is complete.
  • Multiple color/single catalyst systems: disconnect only the component B fluid supply at the flow meter inlet and connect a regulated solvent supply line.
5. The color change LED blinks while Recipe 0 runs and turns solid after purge sequence is complete.
  • Multiple color/multiple catalyst systems: connect the solvent supply lines to the designated solvent valve on the color and catalyst valve stacks. Do not connect a solvent supply to either flow meter.
6. If the system is not completely clean, you can

repeat Recipe 0 by pressing Enter .

System Operation

Page 61 of the Graco Diaphragm Pump (312776F) user manual — System Operation
Page 61 · click to enlarge
Page 61
3. Adjust the solvent fluid supply pressure. Use the lowest possible pressure to avoid splashing.
4. Remove the Fluid Station cover to access the solenoid valves. See F IG . 65.
5. Purge as follows:
  • Single color/single catalyst systems: Purge component A side. Press the manual override on the Dose Valve A solenoid valve and trigger the gun into a grounded metal pail.

Purge component B side. Press the manual override on the Dose Valve B solenoid valve and trigger the gun into a grounded metal pail until clean solvent flows from the gun.

Repeat to thoroughly clean the fluid integrator.

  • Multiple color/single catalyst systems:

Select Recipe 0 and press Enter to purge the component A side. The color change LED blinks while Recipe 0 runs and turns solid after purge sequence is complete.

Purge component B side. Press the manual override on the Dose Valve B solenoid valve and trigger the gun into a grounded metal pail until clean solvent flows from the gun.

Repeat to thoroughly clean the fluid integrator.

  • Multiple color/multiple catalyst systems:

Select Recipe 0 and press Enter to purge the component A side and the component B side. The color change LED blinks while Recipe 0 runs and turns solid after purge sequence is complete.

Repeat to thoroughly clean the fluid integrator.

6. Reinstall the Fluid Station cover.
7. Shut off the solvent fluid supply.
8. Disconnect the solvent supply lines and reconnect the component A and B fluid supplies.
9. See page 53 for Start Up procedure.

System Operation

Page 62 of the Graco Diaphragm Pump (312776F) user manual — Purging Sampling Valves and Tubes
Page 62 · click to enlarge
Page 62

Purging Sampling Valves and Tubes

8. Close sampling valves.

Follow this procedure after meter calibration.

1. Press the Standby key on the Booth Control.
9. Fully open both fluid shutoff valves.
2. See F IG . 67. Close both fluid shutoff valves and sampling valves.
10. On a single color system, reconnect component A fluid supply line to flow meter A.
3. Route the sampling tubes into a grounded waste container.
4. On a single color system, attach a solvent supply line to Flow Meter A inlet.
5. On the EasyKey, press the Setup key and

access the Advanced Setup screens.

6. Press the Right Arrow key to select the Calibra-

tion screen. Press the Down Arrow key and

select Purge from the menu. Press the Enter key.

Dose A, solvent purge valve (B side), and color change solvent valves (if used) will open.

FIG. 68. Calibration Screen

7. To avoid splashing, slowly open the sampling valves and dispense solvent until the valves and tubes are clean.

System Operation

Page 63 of the Graco Diaphragm Pump (312776F) user manual — MS
Page 63 · click to enlarge
Page 63

Solvent Push Feature

The Solvent Push feature enables the user to save some mixed material by pushing it out to the gun with solvent. The quantity saved is 50% of the potlife volume entered in Advanced Setup Screen 1 on page 35. If there are 2 guns, the smaller potlife volume is used.

close the Dose Valves (DVA, DVB) and open the Solvent Purge Valve (SPV).

4. The system will dispense solvent to push the mixed material out to the gun. The Booth Control display alternately shows dashes and the percent remaining (0-99%) of the 50% of the potlife volume.

Solvent Push requires an accessory solvent meter (MS). Order Graco Part No. 16D329 S3000 Solvent Meter Kit. See manual 308778.

Standby key. The Solvent Purge Valve (SPV) or

1. See F IG . 69. Install the solvent meter (MS) on the side of the fluid station, as explained in the ProMix 2KS Installation Manual.

3rd purge valve will close. To re-enter Solvent Push,

press the Mix key.

2. To enable Solvent Push, select “Solvent” or “3rd Valve,” as desired. See Option Screen 2 , page 33.
5. When the total solvent dispensed exceeds 50% of the potlife volume, the system will go into Standby

mode.

6. Perform a manual purge or recipe change to purge the remaining mixed material. This will clear the system out of Solvent Push, allowing you to resume Mix mode.
3. Press and hold the Mix key for 5 seconds to turn on Solvent Push. The green Mix LED will light and the Recipe LED will blink. The system will

Key: DVA Component A Dose Valve DVB Component B Dose Valve MS Solvent Meter (required) SPV Solvent Purge Valve APV Air Purge Valve SMC Solvent Meter Cable SS Solvent Supply Line

MS

SMC

SS

FIG. 69. Solvent Push Setup

Show 5 more labels / short text on this page
System Operation · DVA is closed · DVB is closed · TI12556b · SPV is open
Page 64 of the Graco Diaphragm Pump (312776F) user manual — Mix Fill Push Feature
Page 64 · click to enlarge
Page 64

Mix Fill Push Feature

The Mix Fill Push feature enables the user to prevent potlife expiration of material by mixing and flowing new material through the Gun Flush Box.

1. The system gets a Potlife alarm.
2. The buzzer will do a double "chirp" every 4 seconds to indicate an impending Mix Fill Push.

Mix Fill Push requires an accessory Gun Flush Box for each gun that will use this feature. Order Graco Part No. 15V826 Fun Flush Box Kit. See manual 312784.

3. After waiting for the 2-minute Auto Dump time the system will run the Mix Fill Push.
4. If one of the guns in not in the GFB, the system will not perform any of the Mix Fill Push or Auto Dump operations. The system will retry every 30 seconds in case the gun is then installed in the GFB.

Mix Fill Push requires a Gun Flush Box for the gun. If two guns are used, each requires a Fun Flush Box for this feature to operate. The second Gun Flush Box must be configured as a Special Output. See Configure Screen 5 on page 31.

5. With the guns in the GFBs, the system will proportion mixed material through the guns in order to reset the potlife volume.
6. The alarm is cleared.

To enable Mix Fill Push, select “Mix Fill Push” in the Auto Dump field. See Option Screen 2, page 33.

7. The event is logged in the Alarm Log as two alarms: E-5 Overdose A and E-6 Overdose B.
Graco Diaphragm Pump (312776F) — Mix Fill Push Feature diagram (page 64)
Fig. 92 · Mix Fill Push Feature

FIG. 70. Mix Fill Push Timing Chart

System Operation

Page 65 of the Graco Diaphragm Pump (312776F) user manual — Meter Calibration
Page 65 · click to enlarge
Page 65

Meter Calibration

4. Place the beakers (minimum size - 250 cc) in holders. Put the sampling tubes into the beakers.

To avoid splashing fluid in the eyes, wear eye protec- tion. The fluid shutoff valves and ratio check valves are retained by mechanical stops that prevent accidental removal of the valve stem while the manifold is pres- surized. If you cannot turn the valve stems manually, relieve the system pressure, then disassemble and clean the valve to remove the resistance.

5. On the EasyKey, press the Setup key to access

setup screens.

6. Select Recipe & Advanced Setup and press the

Enter key to select.

Calibrate the meter:

  • The first time the system is operated.
  • Whenever new materials are used in the system, especially if the materials have viscosities that differ significantly.
  • At least once per month as part of regular maintenance.
  • Whenever a flow meter is serviced or replaced.
7. Press the Right Arrow key to select the Calibra-

tion Screen. Press the Enter key to select either A Meter, B Meter, or Solvent. Press the Down

  • K-factor values on the screen are viewable only. If needed, you can manually edit the K-factors in Advanced Setup Screen 4 (page 36) or Recipe Setup Screen 5 (page 41).

Arrow key and select Start from the menu. Start only one at a time.

  • All values on this screen are in cc, independent of the units set in Configure Screen 1 .
  • The controller will use the active recipe K-factors for meter calibration. The active recipe must be recipe 1 to recipe 60. Recipes 0 and 61 do not have K-factor values.
1. Before calibrating meter A or B, prime the system with material. For a color/catalyst change system, make sure the color/catalyst valve is open.
2. Shut off all spray or dispense devices connected to the ProMix.
3. Close both fluid shutoff valves and sampling valves.

Meter Calibration

Page 66 of the Graco Diaphragm Pump (312776F) user manual — Meter Calibration
Page 66 · click to enlarge
Page 66
8. Dispense component A, B, or Solvent into beaker.
12. After the volume for A, B, or Solvent is entered, the ProMix 2KS controller calculates the new flow meter K-factor and shows it on the Calibration Screen .

a. To avoid splashing, slowly open sampling valves.

13. Always purge sampling valves after calibrating meters. Use one of the following methods.

b. For more accurate calibration, adjust the valve to dispense at a flow rate similar to your produc- tion spray flow rate.

  • Follow the Purging Sampling Valves and Tubes procedure, page 62.

c. Dispense a minimum of 250 cc; make sure enough material is dispensed to accurately read the volume with your beaker. The A and B vol- umes do not have to be equal or at any particu- lar ratio.

  • Place the sampling valve fluid tubes into a compatible cleaning fluid (TSL or solvent) or cap them.

d. Close sampling valve tightly.

9. The volume that the ProMix measured displays on the EasyKey.
14. Make sure both sampling valves are closed and both fluid shutoff valves are fully open.
10. Compare the amounts on the EasyKey to the amount in the beakers.
15. Before you begin production, clear the system of solvent and prime it with material.

a. Go to Mix mode.

b. Trigger the gun into a grounded metal pail until mixed material flows from the gun nozzle.

11. If the screen and actual volumes are different, enter the actual dispensed volume in cc for A, B, or Sol-

c. To begin operation, see Start Up, page 53.

vent Volume field, and press the Enter key.

If the value was substantially different, repeat the calibration process.

Screen menu and press the Enter key.

Meter Calibration

Page 67 of the Graco Diaphragm Pump (312776F) user manual — Single Color Systems
Page 67 · click to enlarge
Page 67

Color Change

Color Change Procedures

Color Change Sequences

FIG. 71 through FIG. 80 illustrate various color change sequences. See Table 9 to determine which figure to reference, based on the recipe change and system con- figuration. The time sequences are detailed in the fol- lowing paragraphs.

Multiple Color Systems

1. Shut off air to the gun.
2. Place the gun in the gun flush box if used, and close the lid.
3. Switch to Standby mode at the Booth Control.
4. Use the scroll keys, or , to select the new

color. Press Enter to begin the color change sequence.

NOTES:

  • The system uses old recipe data for the purge cycle. However, it opens the new color/catalyst valve based on the new recipe data.
5. If a gun flush box is not used, trigger the gun into a grounded metal pail until the color change sequence is complete.
  • The system uses the new recipe data for the fill cycle.
6. When the color change indicator light stops flashing on the Booth Control, the color change sequence is complete.
  • For the one gun flush box (GFB) option, the spray gun must be inserted in the GFB during the entire color change cycle (purge and fill). The GFB trigger output will be on during the recipe change cycle.
  • For the two gun flush box (GFB) option, both spray guns must be inserted in the GFBs during the entire color change cycle (purge and fill). The system will turn each GFB trigger output on and off based on the preset time for each gun.

mode at the previous color.

7. When you are ready to spray, remove the gun from the gun flush box if used, and close its door.
  • For Special Outputs options, the system will turn each output on and off based on the preset times. Each Special Output has two different start times and durations.
  • For systems without dump valves, the First Purge begins after the Color/Catalyst Change steps are completed.
8. Press the Mix key to start spraying.

Single Color Systems

  • Dump Valve B is required for a Catalyst Change system.
1. Follow procedure for Purging Fluid Supply System , page 60.
  • When going from Recipe X to Recipe 0, only the purge cycle data from Recipe 0 is used.
2. Load the new color. See Start Up , page 53.
3. Press the Mix key to start spraying.
  • When going from Recipe 0 to Recipe Y, only the fill cycle data from Recipe Y is used.

Color Change

Page 68 of the Graco Diaphragm Pump (312776F) user manual — Catalyst Fill
Page 68 · click to enlarge
Page 68

Color Purge/Dump

First Purge

  • This sequence flushes out the color with solvent, from the color valve to the Dump A valve.

Select the First Purge Source (air, solvent, or 3rd valve) and First Purge Time. For most applications, air is selected.

  • The color change solvent valve and the Dump A valve open during the Purge Time.

The system purges the old material from the dose valves to the gun, using only the selected purge media (usually air). The selected purge valve opens during the First Purge Time and closes when the time expires.

  • The color change solvent valve closes when the Purge Time expires.

Color Fill

Chop Cycle

  • This sequence fills the line with the new color all the way to the Dump A valve.

Select the Chop Type (air/solvent or air/3rd valve) and Chop Times.

  • The new color valve and the Dump A valve open during the Fill Time.

The air purge valve opens only during the air chop cycle, and the solvent (or 3rd valve) opens only during the solvent chop cycle. The number of chop cycles is determined by dividing the Total Chop Time by the sum of the Air and Solvent Chop Times.

  • The new color valve and the Dump A valve close when the Fill Time expires.

Catalyst Purge/Dump

Final Purge

  • This sequence flushes out the catalyst with solvent, from the catalyst valve to the Dump B valve.

Select the Final Purge Source (air, solvent, or 3rd valve) and Final Purge Time. For most applications, solvent is selected.

  • The catalyst change solvent valve and the Dump B valve open during the Purge Time.

The system fills the line with solvent from the dose valves to the gun, using only the selected purge media (usually solvent). The selected purge valve opens during the Final Purge Time and closes when the time expires.

  • The catalyst change solvent valve closes when the Purge Time expires.

Catalyst Fill

Fill

  • This sequence fills the line with the new catalyst all the way to the Dump B valve.

This sequence fills the line from the dose valves to the gun, and is also referred to as the mixed material fill. The system begins mixing components A and B until the Fill Time expires.

  • The new catalyst valve and the Dump B valve open during the Fill Time.
  • The new catalyst valve and the Dump B valve close when the Fill Time expires.

Color Change

Page 69 of the Graco Diaphragm Pump (312776F) user manual — Color Change
Page 69 · click to enlarge
Page 69
Table 9Color Change Chart Reference

Type Dump A Exiting Fill Refer to Fig.

X Y Change Yes NA FIG. 71

X Y Change No NA FIG. 72

0 Y Fill Yes Yes FIG. 73

0 Y Fill Yes No FIG. 74

0 Y Fill No Yes FIG. 75

0 Y Fill No No FIG. 76

X 0 Purge Yes NA FIG. 77

X 0 Purge No NA FIG. 78

0 0 Purge Yes NA FIG. 79

0 0 Purge No NA FIG. 80

Show 5 more labels / short text on this page
Color Change · Starting · Ending Recipe · Change · Recipe
Page 70 of the Graco Diaphragm Pump (312776F) user manual — Color Change
Page 70 · click to enlarge
Page 70

3 + GFB on #4 2KS X to Y K15

Fill Active Output End of Color Change ->

Special Output #4

Solvent A If a component is not changing, that time segment is skipped

Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time

First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Color Change Stack Flush Sequence Color Change Stack Components

Mixed Fill Time using Sequential Dosing

Mixed Fill Time using Dynamic Dosing

Dump B Flush out old catalyst and fill with new catalyst

Dose Valve and Integrator Flush Sequence Purge Operation Details

Special Output #3

2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2

Dump A Flush out old color and fill with new color

Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2

3rd Purge Valve on A If Chop Type is "Air/3rd Purge"

Purge B (Solvent) If Chop Type is "Air/Solvent"

Special Output #2

Purge A (Air) Fixed for Purge A (Air)

This happens on the same time scale as the Dose Valve and Integrator Flush Sequence

Special Outputs

Dose Valve and Integrator Flush Purge and Chop Operations by Time

Special Output #1

A Fill A Purge Color Change Stack Purge and Fill Operations by Time

Dose Valve and Integrator Mix Fill Operations by Time

Discrete I/O Signals by Time

Final Purge First Purge Total Chop

B Fill B Purge

ProMix 2KS Recipe Change Chart #1 X to Y

Dump A Enabled, 3rd Flush Valve Enabled

Stack Valves A1 to A2, B1 to B2

Color Change Input

F IG . 71ProMix 2KS Recipe Change Chart #1 X to Y

Purge from X, Fill from Y -->

Purge from X -->

Fill from Y -->

Separate Gun 1 and Gun 2

Separate Gun 1 and Gun 2

If No Gun Flush Boxes

1 Gun Gun Flush Box Output 1

2 Guns Gun Flush Box Output 1

Gun Trigger(s) by Operator

Gun Flush Box Output 2

Gun Flush Box Output 2

Show 16 more labels / short text on this page
Color Change · Waiting · 2 s B · Color/Catalyst/(Reducer) · Stack Valves · Purge Valves · Dose Valves · GFB Outputs · Digital I/O · Purge Active Output · Mix Ready Output · Component A · Component B · Solvent B · Dose A · Dose B
Page 71 of the Graco Diaphragm Pump (312776F) user manual — Color Change
Page 71 · click to enlarge
Page 71

3 + GFB on #4 2KS X to Y K13

Fill Active Output End of Color Change ->

Special Output #4

Solvent A If a component is not changing, that time segment is skipped

Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time

First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Mixed Fill Time using Sequential Dosing

Mixed Fill Time using Dynamic Dosing

Color Change Stack Flush Sequence Color Change Stack Components A Fill A Purge B Fill B Purge

Special Output #3

Dump B Flush out old catalyst and fill with new catalyst

Dose Valve and Integrator Flush Sequence Purge Operation Details

2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2

Dump A Flush out old color and fill with new color

Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2

3rd Purge Valve on A If Chop Type is "Air/3rd Purge"

Purge B (Solvent) If Chop Type is "Air/Solvent"

This happens on the same time scale as the Dose Valve and Integrator Flush Sequence

Special Output #2

Purge A (Air) Fixed for Purge A (Air)

Special Outputs

Dose Valve and Integrator Flush Purge and Chop Operations by Time

Special Output #1

Color Change Stack Purge and Fill Operations by Time

Dose Valve and Integrator Mix Fill Operations by Time

Final Purge 2 s B

Discrete I/O Signals by Time

Dose A

ProMix 2KS Recipe Change Chart #2 X to Y

No Dump A, 3rd Flush Valve Enabled

Stack Valves A1 to A2, B1 to B2

Total Chop First Purge Waiting

F IG . 72ProMix 2KS Recipe Change Chart #2 X to Y

Color Change Input

Purge from X, Fill from Y -->

Purge from X -->

Fill from Y -->

Separate Gun 1 and Gun 2

Separate Gun 1 and Gun 2

If No Gun Flush Boxes

Gun Trigger(s) by Operator

1 Gun Gun Flush Box Output 1

2 Guns Gun Flush Box Output 1

Gun Flush Box Output 2

Gun Flush Box Output 2

Show 16 more labels / short text on this page
Color Change · Waiting · GFB 1 Only · No Dump A · Color/Catalyst/(Reducer) · Purge Valves · GFB Outputs · Stack Valves · Dose Valves · Digital I/O · Purge Active Output · Mix Ready Output · Component A · Component B · Solvent B · Dose B
Page 72 of the Graco Diaphragm Pump (312776F) user manual — Color Change
Page 72 · click to enlarge
Page 72

3 + GFB on #4 2KS 0 to Y K15

Fill Active Output End of Color Change ->

Special Output #4

Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time

Exiting Fill Selection Recipe 0Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Color Change Stack Fill Sequence Color Change Stack Components

First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Mixed Fill Time using Sequential Dosing

Mixed Fill Time using Dynamic Dosing

Dose Valve and Integrator Flush Sequence Purge Operation Details

Special Output #3

2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2

Dump B Push out solvent and fill with new catalyst

Dump A Push out solvent and fill with new color

Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2

Solvent A Only active components are filled

3rd Purge Valve on A If Chop Type is "Air/3rd Purge"

Purge B (Solvent) If Chop Type is "Air/Solvent"

This happens on the same time scale as the Dose Valve and Integrator Flush Sequence

Special Output #2

Purge A (Air) Fixed for Purge A (Air)

Dose Valve and Integrator Flush Purge and Chop Operations by Time

Special Outputs

Color Change Stack Purge and Fill Operations by Time

Special Output #1

Dose Valve and Integrator Mix Fill Operations by Time

Discrete I/O Signals by Time

Dump A Enabled, 3rd Flush Valve Enabled

ProMix 2KS Recipe Fill Chart #3 0 to Y

B Fill A Fill

Stack Valves A1, B1

Exit. Fill Waiting

Color Change Input

F IG . 73ProMix 2KS Recipe Fill Chart #3 0 to Y

No Purge, Fill from Y -->

Fill from Y -->

Separate Gun 1 and Gun 2

Separate Gun 1 and Gun 2

If No Gun Flush Boxes

Gun Trigger(s) by Operator

1 Gun Gun Flush Box Output 1

2 Guns Gun Flush Box Output 1

Gun Flush Box Output 2

Gun Flush Box Output 2

Show 18 more labels / short text on this page
Color Change · Exiting Fill Enabled · From Recipe 0 · Waiting · No Purge --> · Color/Catalyst/(Reducer) · Stack Valves · Purge Valves · Dose Valves · GFB Outputs · Digital I/O · Purge Active Output · Mix Ready Output · Component A · Component B · Solvent B · Dose A · Dose B
Page 73 of the Graco Diaphragm Pump (312776F) user manual — Color Change
Page 73 · click to enlarge
Page 73

3 + GFB on #4 2KS 0 to Y K14

Fill Active Output End of Color Change ->

Special Output #4

Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time

First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Mixed Fill Time using Sequential Dosing

Mixed Fill Time using Dynamic Dosing

Color Change Stack Flush Sequence Color Change Stack Components A Fill B Fill Color Change Stack Purge and Fill Operations by Time

Special Output #3

Dose Valve and Integrator Flush Sequence Purge Operation Details

2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2

Dump B Push out solvent and fill with new catalyst

Dump A Push out solvent and fill with new color

Solvent A Only active components are filled

Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2

3rd Purge Valve on A If Chop Type is "Air/3rd Purge"

Purge B (Solvent) If Chop Type is "Air/Solvent"

This happens on the same time scale as the Dose Valve and Integrator Flush Sequence

Special Output #2

Purge A (Air) Fixed for Purge A (Air)

Special Outputs

Dose Valve and Integrator Flush Purge and Chop Operations by Time

Special Output #1

Dose Valve and Integrator Mix Fill Operations by Time

Discrete I/O Signals by Time

Dump A Enabled, 3rd Flush Valve Enabled

ProMix 2KS Recipe Fill Chart #4 0 to Y

Stack Valves A1, B1

Color Change Input

F IG . 74ProMix 2KS Recipe Fill Chart #4 0 to Y

No Purge, Fill from Y -->

Fill from Y -->

Separate Gun 1 and Gun 2

Separate Gun 1 and Gun 2

If No Gun Flush Boxes

Gun Trigger(s) by Operator

1 Gun Gun Flush Box Output 1

2 Guns Gun Flush Box Output 1

Gun Flush Box Output 2

Gun Flush Box Output 2

Show 17 more labels / short text on this page
Color Change · No Exiting Fill · Waiting · No Purge --> · Color/Catalyst/(Reducer) · Purge Valves · GFB Outputs · Stack Valves · Dose Valves · Digital I/O · Purge Active Output · Mix Ready Output · Component A · Component B · Solvent B · Dose A · Dose B
Page 74 of the Graco Diaphragm Pump (312776F) user manual — Color Change
Page 74 · click to enlarge
Page 74

3 + GFB on #4 2KS 0 to Y K13

Fill Active Output End of Color Change ->

Special Output #4

Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time

Color Change Stack Fill Sequence Color Change Stack Components

Exiting Fill Selection Recipe 0Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Mixed Fill Time using Sequential Dosing

Mixed Fill Time using Dynamic Dosing

First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Dose Valve and Integrator Flush Sequence Purge Operation Details

Special Output #3

2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2

Dump B Push out solvent and fill with new catalyst

Dump A Push out solvent and fill with new color

Solvent A Only active components are filled

3rd Purge Valve on A If Chop Type is "Air/3rd Purge"

Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2

Purge B (Solvent) If Chop Type is "Air/Solvent"

Special Output #2

Purge A (Air) Fixed for Purge A (Air)

This happens on the same time scale as the Dose Valve and Integrator Flush Sequence

Special Outputs

Special Output #1

Dose Valve and Integrator Flush Purge and Chop Operations by Time

Color Change Stack Purge and Fill Operations by Time

Dose Valve and Integrator Mix Fill Operations by Time

Discrete I/O Signals by Time

Dose A

ProMix 2KS Recipe Fill Chart #5 0 to Y

No Dump A, 3rd Flush Valve Enabled

Waiting A Fill B Fill

Stack Valves A1, B1

Exit. Fill Waiting

F IG . 75ProMix 2KS Recipe Fill Chart #5 0 to Y

Color Change Input

No Purge, Fill from Y -->

Fill from Y -->

Separate Gun 1 and Gun 2

Separate Gun 1 and Gun 2

If No Gun Flush Boxes

Gun Trigger(s) by Operator

1 Gun Gun Flush Box Output 1

2 Guns Gun Flush Box Output 1

Gun Flush Box Output 2

Gun Flush Box Output 2

Show 18 more labels / short text on this page
Color Change · Exiting Fill Enabled · No Dump A · GFB 1 Only · From Recipe 0 · No Purge --> · Color/Catalyst/(Reducer) · Purge Valves · GFB Outputs · Stack Valves · Dose Valves · Digital I/O · Purge Active Output · Mix Ready Output · Component A · Component B · Solvent B · Dose B
Page 75 of the Graco Diaphragm Pump (312776F) user manual — Color Change
Page 75 · click to enlarge
Page 75

3 + GFB on #4 2KS 0 to X K12

Fill Active Output End of Color Change ->

Special Output #4

Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time

Color Change Stack Flush Sequence Color Change Stack Components

Mixed Fill Time using Sequential Dosing

Mixed Fill Time using Dynamic Dosing

First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Dose Valve and Integrator Flush Sequence Purge Operation Details

Special Output #3

2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2

Dump B Push out solvent and fill with new catalyst

Dump A Push out solvent and fill with new color

GFB 1 Only Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2

Solvent A Only active components are filled

3rd Purge Valve on A If Chop Type is "Air/3rd Purge"

Purge B (Solvent) If Chop Type is "Air/Solvent"

This happens on the same time scale as the Dose Valve and Integrator Flush Sequence

Special Output #2

Purge A (Air) Fixed for Purge A (Air)

Dose Valve and Integrator Flush Purge and Chop Operations by Time

Special Outputs

Color Change Stack Purge and Fill Operations by Time

Dose Valve and Integrator Mix Fill Operations by Time

Special Output #1

Discrete I/O Signals by Time

ProMix 2KS Recipe Fill Chart #6 0 to Y

No Dump A, 3rd Flush Valve Enabled

Dose A

Stack Valves A1, B1

A Fill B Fill

F IG . 76ProMix 2KS Recipe Fill Chart #6 0 to Y

Color Change Input

No Purge, Fill from Y -->

Fill from Y -->

Separate Gun 1 and Gun 2

Separate Gun 1 and Gun 2

If No Gun Flush Boxes

Gun Trigger(s) by Operator

2 Guns Gun Flush Box Output 1

1 Gun Gun Flush Box Output 1

Gun Flush Box Output 2

Gun Flush Box Output 2

Show 17 more labels / short text on this page
Color Change · No Exiting Fill · Waiting · No Dump A · No Purge --> · Color/Catalyst/(Reducer) · Stack Valves · Purge Valves · Dose Valves · GFB Outputs · Digital I/O · Purge Active Output · Mix Ready Output · Component A · Component B · Solvent B · Dose B
Page 76 of the Graco Diaphragm Pump (312776F) user manual — Color Change
Page 76 · click to enlarge
Page 76

3 + GFB on #4 2KS X to 0 K15

Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time

Color Change Stack Flush Sequence Color Change Stack Components A Purge B Purge

Mixed Fill Time using Sequential Dosing

Mixed Fill Time using Dynamic Dosing

First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Dose Valve and Integrator Flush Sequence Purge Operation Details

Solvent A Every recipe 0 entry will flush all components

2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2

Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2

3rd Purge Valve on A If Chop Type is "Air/3rd Purge"

Purge B (Solvent) If Chop Type is "Air/Solvent"

This happens on the same time scale as the Dose Valve and Integrator Flush Sequence

Dump B Flush out old catalyst

Purge A (Air) Fixed for Purge A (Air)

Dump A Flush out old color

Dose Valve and Integrator Flush Purge and Chop Operations by Time

Color Change Stack Purge and Fill Operations by Time

Dose Valve and Integrator Mix Fill Operations by Time

Discrete I/O Signals by Time

Purge Active Output End of Color Change ->

ProMix 2KS Recipe Purge Chart #7 X to 0

Dump A Enabled, 3rd Flush Valve Enabled

First Purge Total Chop Final Purge

Special Output #4

This activates for Autodump operations only

Special Output #3

F IG . 77ProMix 2KS Recipe Purge Chart #7 X to 0

Color Change Input

Special Output #2

Special Outputs

Special Output #1

Purge from 0, No Fill -->

Purge from 0 -->

Separate Gun 1 and Gun 2

Separate Gun 1 and Gun 2

If No Gun Flush Boxes

Gun Trigger(s) by Operator

1 Gun Gun Flush Box Output 1

Gun Flush Box Output 2

2 Guns Gun Flush Box Output 1

Gun Flush Box Output 2

Show 17 more labels / short text on this page
Color Change · Stack Valves Off · 2 s B · No Fill --> · Color/Catalyst/(Reducer) · Stack Valves · Purge Valves · Dose Valves · GFB Outputs · Digital I/O · Fill Active Output · Mix Ready Output · Component A · Component B · Solvent B · Dose A · Dose B
Page 77 of the Graco Diaphragm Pump (312776F) user manual — Color Change
Page 77 · click to enlarge
Page 77

3 + GFB on #4 2KS X to 0 K13

Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time

Mixed Fill Time using Sequential Dosing

Color Change Stack Flush Sequence Color Change Stack Components Waiting

First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Mixed Fill Time using Dynamic Dosing

Dose Valve and Integrator Flush Sequence Purge Operation Details

Solvent A Every recipe 0 entry will flush all components

2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2

Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2

3rd Purge Valve on A If Chop Type is "Air/3rd Purge"

Purge B (Solvent) If Chop Type is "Air/Solvent"

This happens on the same time scale as the Dose Valve and Integrator Flush Sequence

Dump B Flush out old catalyst

Purge A (Air) Fixed for Purge A (Air)

Dump A Flush out old color

Dose Valve and Integrator Flush Purge and Chop Operations by Time

Color Change Stack Purge and Fill Operations by Time

Dose Valve and Integrator Mix Fill Operations by Time

Discrete I/O Signals by Time

Purge Active Output End of Color Change ->

Waiting First Purge Total Chop 2 s B Final Purge

ProMix 2KS Recipe Purge Chart #8 X to 0

No Dump A, 3rd Flush Valve Enabled

Dose A

This activates for Autodump operations only

Special Output #4

B Purge A Purge

Special Output #3

F IG . 78ProMix 2KS Recipe Purge Chart #8 X to 0

Color Change Input

Special Output #2

Special Outputs

Special Output #1

Purge from X, Fill from Y -->

Purge from 0 -->

Separate Gun 1 and Gun 2

Separate Gun 1 and Gun 2

If No Gun Flush Boxes

2 Guns Gun Flush Box Output 1

Gun Trigger(s) by Operator

1 Gun Gun Flush Box Output 1

Gun Flush Box Output 2

Gun Flush Box Output 2

Show 17 more labels / short text on this page
Color Change · Stack Valves Off · No Dump A · GFB 1 Only · No Fill --> · Color/Catalyst/(Reducer) · Stack Valves · Purge Valves · Dose Valves · GFB Outputs · Digital I/O · Fill Active Output · Mix Ready Output · Component A · Component B · Solvent B · Dose B
Page 78 of the Graco Diaphragm Pump (312776F) user manual — Color Change
Page 78 · click to enlarge
Page 78

3 + GFB on #4 2KS 0 to 0 K3

Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time

Exiting Fill Selection Recipe 0Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Color Change Stack Flush Sequence Color Change Stack Components

Mixed Fill Time using Sequential Dosing

Mixed Fill Time using Dynamic Dosing

First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Dose Valve and Integrator Flush Sequence Purge Operation Details

Solvent A Every recipe 0 entry will flush all components

2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2

Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2

3rd Purge Valve on A If Chop Type is "Air/3rd Purge"

Dose Valve and Integrator Flush Purge and Chop Operations by Time - From Recipe 0

Purge B (Solvent) If Chop Type is "Air/Solvent"

This happens on the same time scale as the Dose Valve and Integrator Flush Sequence

Color Change Stack Purge and Fill Operations by Time - From Recipe 0

Purge A (Air) Fixed for Purge A (Air)

Dump B Flush out old catalyst

Dump A Flush out old color

Dose Valve and Integrator Mix Fill Operations by Time

Discrete I/O Signals by Time

Purge Active Output End of Color Change ->

Dump A Enabled, 3rd Flush Valve Enabled

Final Purge First Purge

ProMix 2KS Recipe Purge Chart #9 0 to 0

Exit. Fill Total Chop 2 s B

Special Output #4

Waiting A Purge B Purge

Special Output #3

F IG . 79ProMix 2KS Recipe Purge Chart #9 0 to 0

Color Change Input

Special Output #2

Special Outputs

Special Output #1

Purge from 0, No Fill -->

Purge from 0 -->

Separate Gun 1 and Gun 2

Separate Gun 1 and Gun 2

If No Gun Flush Boxes

Gun Trigger(s) by Operator

2 Guns Gun Flush Box Output 1

1 Gun Gun Flush Box Output 1

Gun Flush Box Output 2

Gun Flush Box Output 2

Show 19 more labels / short text on this page
Color Change · Waiting · Stack Valves Off · Exiting Fill Enabled · From Recipe 0 · No Fill --> · Color/Catalyst/(Reducer) · Stack Valves · Purge Valves · Dose Valves · GFB Outputs · Digital I/O · Fill Active Output · Mix Ready Output · Component A · Component B · Solvent B · Dose A · Dose B
Page 79 of the Graco Diaphragm Pump (312776F) user manual — Color Change
Page 79 · click to enlarge
Page 79

3 + GFB on #4 2KS 0 to 0 K1

Gun and Hose Flush Operations by Time Gun and Hose Mix Material Fill Operations by Time

Exiting Fill Selection Recipe 0Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Mixed Fill Time using Sequential Dosing

Color Change Stack Flush Sequence Color Change Stack Components Waiting

First Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Final Purge Selection Select Purge A (Air), Purge B (Solvent), or 3rd Valve on A

Mixed Fill Time using Dynamic Dosing

Dose Valve and Integrator Flush Sequence Purge Operation Details

Solvent A Every recipe 0 entry will flush all components

2 s B Purge after Chop Fixed Purge B. Enabled in Options Screen 2

Each Integrator Flush Purge, Chop, and Mix Material Fill operation runs sequentially for Gun 1 then for Gun 2

3rd Purge Valve on A If Chop Type is "Air/3rd Purge"

Purge B (Solvent) If Chop Type is "Air/Solvent"

Dose Valve and Integrator Flush Purge and Chop Operations by Time - From Recipe 0

Purge A (Air) Fixed for Purge A (Air)

This happens on the same time scale as the Dose Valve and Integrator Flush Sequence

Dump B Flush out old catalyst

Color Change Stack Purge and Fill Operations by Time - From Recipe 0

Dump A Flush out old color

Dose Valve and Integrator Mix Fill Operations by Time

Purge Active Output End of Color Change ->

Final Purge 2 s B Total Chop First Purge Exit. Fill Waiting

Discrete I/O Signals by Time

ProMix 2KS Recipe Purge Chart #10 0 to 0

No Dump A, 3rd Flush Valve Enabled

Waiting B Purge A Purge

Dose A

Special Output #4

Special Output #3

F IG . 80ProMix 2KS Recipe Purge Chart #10 0 to 0

Color Change Input

Special Output #2

Special Outputs

Special Output #1

Purge from 0, No Fill -->

Purge from 0 -->

Separate Gun 1 and Gun 2

Separate Gun 1 and Gun 2

If No Gun Flush Boxes

Gun Trigger(s) by Operator

2 Guns Gun Flush Box Output 1

1 Gun Gun Flush Box Output 1

Gun Flush Box Output 2

Gun Flush Box Output 2

Show 18 more labels / short text on this page
Color Change · Exiting Fill Enabled · Stack Valves Off · No Dump A · From Recipe 0 · No Fill --> · Color/Catalyst/(Reducer) · Stack Valves · Purge Valves · Dose Valves · GFB Outputs · Digital I/O · Fill Active Output · Mix Ready Output · Component A · Component B · Solvent B · Dose B
Page 80 of the Graco Diaphragm Pump (312776F) user manual — System Warnings
Page 80 · click to enlarge
Page 80

Alarms and Warnings

To Reset Alarm and Restart

System Alarms

System alarms alert you of a problem and help prevent off-ratio spraying. If an alarm occurs, operation stops and the following occurs:

To reset alarms, see Table 11. Many alarms can be

  • A red LED illuminates steadily or blinks on the Booth Control.
  • Booth Control displays an alarm E-Code, E-1 to E-28. See F IG . 81.
  • Buzzer sounds (for E-2 only; see page 29 to set for all alarms).
  • Status bar on the EasyKey Display shows the alarm E-Code with a description (see Table 10).

cleared by simply pressing the Alarm Reset key.

Table 10System Alarm/Warning Codes
Graco Diaphragm Pump (312776F) — System Alarms diagram (page 80)
Fig. 93 · System Alarms
Graco Diaphragm Pump (312776F) — System Alarms diagram (page 80)
Fig. 94 · System Alarms

E-5 Overdose A/B Dose Too Short Alarm Page 84

E-6 Overdose B/A Dose Too Short Alarm Page 84

TI11614A

FIG. 81. Booth Control

System Warnings

Table 10 lists the System Warning Codes. Warnings do not stop operation or sound an alarm. They are saved in the date/time stamped log, which can be viewed on a PC, using the ProMix 2KS Web Interface (see manual 313386).

Show 4 more labels / short text on this page
Alarms and Warnings · Alarm Indicator (red) · Display · Recipe Indicator (green)
Page 81 of the Graco Diaphragm Pump (312776F) user manual — E-2: POTLIFE ALARM
Page 81 · click to enlarge
Page 81

Alarm Troubleshooting

Table 11. Alarm Troubleshooting

E-1: COMM ERROR

No power to the EasyKey. Connect power to EasyKey.

No power to Fluid Station. The intrinsically safe power cable between the EasyKey and Fluid Station is not con- nected.

Verify that the cable is correctly connected. See Installa- tion manual.

No power to Fluid Station. The fluid control board fuse is blown.

Verify condition of fuse and replace if necessary. See Repair-Parts manual.

The fiber optic cable between the EasyKey and Fluid Station is not connected.

Verify that the cable is correctly connected. See Installa- tion manual.

The fiber optic cable is cut or bent. Verify that the cable has not been cut or bent at a radius smaller than 1.6 in. (40 mm).

Dirty fiber optic cable ends. Disconnect fiber optic cable ends and clean with a lint-free cloth.

A communication cable or connector failed. Replace cable.

E-2: POTLIFE ALARM

The potlife time has been exceeded for the mixed mate- rial. Press the Alarm Reset key to stop the audible

alarm. Purge the system with solvent, fresh mixed mate- rial, or a new color:

  • Solvent Purge - See Purging Mixed Material on page 59. The system purges until the preset purge time is complete.
  • New Mixed Material Purge - Go to Mix mode and spray the required volume to restart the timer.
  • Color Change - Perform a color change, page 67.

Alarm Troubleshooting · Cause Solution · Cause Solution

Page 82 of the Graco Diaphragm Pump (312776F) user manual — E-3: RATIO HIGH ALARM
Page 82 · click to enlarge
Page 82

Table 11. Alarm Troubleshooting

E-3: RATIO HIGH ALARM

The mix ratio is higher than the set tolerance on the previous dose cycle.

The mix ratio is higher than the set tolerance for an A to B component volume comparison.

There is too little restriction in the system. • Check that the system is fully loaded with material.

  • Check that the supply pump’s cycle rate is set properly.
  • Check that the spray tip/nozzle is properly sized for the flow and application, and that it is not worn.
  • Check that the fluid regulator is set properly.

If the alarm occurs during start up, after purging, the flow rate was probably too high.

Restrict gun needle travel to slow down the initial fluid delivery rate until fluid hoses are loaded with material.

If the alarm occurred after you were spraying for some time, the pressures from the fluid supplies could be unbalanced.

Adjust component A and B fluid supply regulator pres- sures until they are about equal. If the pressures are already about equal, verify that component A and B dose valves are operating properly.

Slow actuation of the component A or B valves. This can be caused by:

Manually operate the Dispense A and B solenoid valves as instructed in the ProMix 2KS Repair-Parts manual to check operation.

  • Air pressure to the valve actuators is too low.
  • Increase air pressure. Air pressure must be 75-120 psi (0.52-0.84 MPa, 5.2-8.4 bar); 120 psi is recommended.
  • Something is restricting the solenoid or tubing and interrupting valve actuation air.
  • There may be dirt or moisture in the air supply. Filter appropriately.
  • A dose valve is turned in too far.
  • Refer to Table 7: Mix Manifold Valve Settings , page 53, for adjustment guidelines.
  • Fluid pressure is high and air pressure is low.
  • Adjust air and fluid pressure. See recommended air pressure above.
Show 4 more labels / short text on this page
Alarm Troubleshooting · Sequential Dosing System · Dynamic Dosing System · Cause Solution
Page 83 of the Graco Diaphragm Pump (312776F) user manual — E-4: RATIO LOW ALARM
Page 83 · click to enlarge
Page 83

Table 11. Alarm Troubleshooting

E-4: RATIO LOW ALARM

The mix ratio is lower than the set tolerance on the previous dose cycle.

The mix ratio is lower than the set tolerance for an A to B component volume comparison.

There is too much restriction in the system. • Check that the system is fully loaded with material.

  • Check that the supply pump’s cycle rate is set properly.
  • Check that the spray tip/nozzle is properly sized for the flow and application, and that it is not clogged.
  • Check that the fluid regulator is set properly.

If the alarm occurs during start up, after purging, the flow rate was probably too high.

Restrict gun needle travel to slow down the initial fluid delivery rate until fluid hoses are loaded with material.

If the alarm occurred after you were spraying for some time, the pressures from the fluid supplies could be unbalanced.

Adjust component A and B fluid supply regulator pres- sures until they are about equal. If the pressures are already about equal, verify that component A and B dose valves are operating properly.

Slow actuation of the component A or B valves. This can be caused by:

Manually operate the Dispense A and B solenoid valves as instructed in the ProMix 2KS Repair-Parts manual to check operation.

  • Air pressure to the valve actuators is too low.
  • Increase air pressure. Air pressure must be 75-120 psi (0.52-0.84 MPa, 5.2-8.4 bar); 120 psi is recommended.
  • Something is restricting the solenoid or tubing and interrupting valve actuation air.
  • There may be dirt or moisture in the air supply. Filter appropriately.
  • A dose valve is turned in too far.
  • Refer to Table 7: Mix Manifold Valve Settings , page 53, for adjustment guidelines.
  • Fluid pressure is high and air pressure is low.
  • Adjust air and fluid pressure. See recommended air pressure above.
Show 4 more labels / short text on this page
Alarm Troubleshooting · Sequential Dosing System · Dynamic Dosing System · Cause Solution
Page 84 of the Graco Diaphragm Pump (312776F) user manual — Alarm Troubleshooting
Page 84 · click to enlarge
Page 84

Table 11. Alarm Troubleshooting

E-5OVERDOSE A/B DOSE TOO SHORT ALARM and E-6: OVERDOSE B/A DOSE TOO SHORT ALARM

E-5: the A dose overshoots and, when combined with B, is too large for the mix chamber capacity.

E-6: the B dose overshoots and forces an A side dose that, when combined with B, is too large for the mix chamber capacity.

Valve seal or needle/seat are leaking. Check FIG. 11 Totals Screen on page 23. If A and B are dosing simul- taneously (sequential dosing only), there is a leak.

Repair the valve (see valve manual 312782).

Sampling valve is leaking. Tighten or replace valve.

Flow meter fluctuations caused by pressure pulsations. Check for pressure pulsations:

1. Close all the manifold valves.
2. Turn on the circulating pumps and all the booth equipment (such as fans and conveyors).
3. Check if the ProMix 2KS is reading any fluid flow.
4. If the ProMix 2KS shows there is fluid flow and there are no leaks from the gun or any other seals or fittings, the flow meters are probably being affected by pressure pulsations.
5. Close the fluid shutoff valve between the fluid supply system and the flow meter. The flow indication should stop.
6. If necessary, install pressure regulators or a surge tank on the fluid inlets to the ProMix 2KS to reduce the fluid supply pressure. Contact your Graco distributor for information.

Slow actuation of component A or B valves. See E-3: RATIO HIGH ALARM and E-4: RATIO LOW ALARM, pages 82-83.

Running a high mix ratio and a high flow rate. It may be necessary to restrict the flow rate through the component B dose valve by adjusting its hex nut (E). See page 51.

Alarm Troubleshooting · Cause Solution

Page 85 of the Graco Diaphragm Pump (312776F) user manual — Alarm Troubleshooting
Page 85 · click to enlarge
Page 85

Table 11. Alarm Troubleshooting

E-7DOSE TIME A ALARM and E-8: DOSE TIME B ALARM

E-7: gun trigger input is active (AFS or Integration) and fewer than 31 A meter pulses were detected during the dose time selected.

E-8: gun trigger input is active (AFS or Integration) and fewer than 31 B meter pulses were detected during the dose time selected.

Fully trigger the gun.

System is in Mix mode and gun is only partially triggered, allowing air but no fluid to pass through gun.

Fluid flow rate is too low. Increase flow rate.

Dose time setting is too short for the current flow rate. Increase the dose time setting.

Flow meter or cable failed or flow meter clogged. To check meter sensor operation, remove meter cap to expose sensor. Pass a ferrous metal tool in front of the sensor.

Graco Diaphragm Pump (312776F) — Alarm Troubleshooting diagram (page 85)
Fig. 95 · Alarm Troubleshooting

If there is a meter or cable failure, you will see a large dif- ference between the amount of fluid dispensed and the flow meter volume displayed by the EasyKey. Clean or repair meter as necessary. Also see meter manual 308778.

Follow Meter Calibration procedure, page 65.

Slow actuation of component A or B valves. See E-3: RATIO HIGH ALARM and E-4: RATIO LOW ALARM, pages 82-83.

The supply pump is not turned on. Turn on the supply pump.

There is an air leak downstream from the air flow switch. Check the air lines for leaks and repair.

The air flow switch is stuck open. Clean or replace air flow switch.

System is in Mix mode with 0 volume entered for Min Material Fill Volume (see Option Screen 1, page 32), and Fuse F1 is blown.

Verify condition of fuse and replace if necessary. See Repair-Parts manual.

Alarm Troubleshooting · Cause Solution · TI12792a

Page 86 of the Graco Diaphragm Pump (312776F) user manual — E-11: PURGE VOLUME ALARM
Page 86 · click to enlarge
Page 86

Table 11. Alarm Troubleshooting

E-9Not used

E-10: REMOTE STOP ALARM

Automation has requested that the system abort all oper- ations.

Abort operations. Troubleshoot automation system.

E-11: PURGE VOLUME ALARM

ProMix 2KS solvent flow switch is not activated while purging.

Verify that the gun is not shut off and that the solvent flow switch is activated while purge is taking place.

Minimum flush volume is not achieved. Increase solvent supply or decrease minimum volume setting.

No meter pulses during Color/Catalyst Dump. Color change solvent supply not set up or functional. Check Color Change setup.

Alarm Troubleshooting · Cause Solution · Cause Solution

Page 87 of the Graco Diaphragm Pump (312776F) user manual — E-12: CAN COMM ERROR ALARM
Page 87 · click to enlarge
Page 87

Table 11. Alarm Troubleshooting

E-12: CAN COMM ERROR ALARM

Communication between the Color Change Module and the Fluid Station is interrupted.

  • Verify that all cables are connected securely and that the Color Change and Booth Control power LEDs turn on. If the power LED does not turn on, the problem is probably caused by a bad connection. The nut on the connector must make at least 5 complete turns to ensure a good connection. If the power LED still does not light, the cable or board is bad.
  • Check the color change board DIP switch settings. See the Installation manual.
  • Check the fluid plate board DIP switch setting. An incorrect setting will not cause E-12 alarms, but a correct setting will help prevent E-12 caused by electrical noise. See the Installation manual.
  • Check EasyKey software version (displayed at power up for all versions and when the lock key is pressed for version 2.02.000 and above). If older than 1.06.002, upgrade. Be sure to save settings through BWI or AWI before upgrading, as they will be erased.
  • The sticker on the color change board shows the software part number and version, for example 15T270 1.01. If the version is older than 1.01, replace the board.
  • If all software versions and DIP switch settings are correct and you still have E-12 alarms, then the system has a bad connection, bad cable, or bad circuit board. Use a multimeter on the CAN connectors to test whether there is a good connection between systems. If there is, you have a bad circuit board. If there is not, you have a bad connector, connection, or cable.
  • Appears on the EasyKey display if the unit is programmed for Manual Mode, and a booth control is not connected.
  • The dip switch settings on the Color Change Module were changed (see manual 312787) while the power was on. Cycle the power to clear the alarm.
  • The dip switch configuration on the Color Change Control Module (see manual 312787) is setup incorrectly.

Communication between the Color Change Module and the Fluid Station is interrupted. The fluid control board fuse is blown.

Verify condition of fuse and replace if necessary. See Repair-Parts manual.

Communication between the Booth Control and the Fluid Station is interrupted.

Verify that the cable is correctly connected.

Alarm Troubleshooting · Cause Solution

Page 88 of the Graco Diaphragm Pump (312776F) user manual — E-18: DEFAULTS LOADED WARNING
Page 88 · click to enlarge
Page 88

Table 11. Alarm Troubleshooting

E-13HIGH FLOW ALARM or E-14: LOW FLOW ALARM (may also be set as Warnings)

Fluid system is producing too much or too little flow. Troubleshoot fluid system for restrictions, leaks, exhausted fluid supply, incorrect settings, etc. Increase or decrease flow rate, as required.

E-15: SYSTEM IDLE WARNING

Mix input is high, but the gun has not been triggered for 2 minutes.

If not painting, clear alarm and resume operation.

If painting, shut down and inspect fluid meter and air flow switch.

E-16: SETUP CHANGE WARNING

The system setup parameters have been changed. No action required. See Event Log available through advanced web interface.

E-17: POWER ON/POWER OFF WARNING

The power to the system has been cycled. No action required. See Event Log available through advanced web interface.

Voltage becoming too low due to weak power supply. Replace power supply. See Repair-Parts manual.

Power wires are disconnected or making intermittent contact.

Check that all wires are securely connected. Ensure that wires are not stretched too tightly.

Reset button has been pushed (S1 on EasyKey display board, S3 on Autokey).

No action required. See Event Log available through advanced web interface.

Software update is initiated on EasyKey. No action required. See Event Log available through advanced web interface.

E-18: DEFAULTS LOADED WARNING

The factory defaults have been installed on the system. No action required. See Event Log available through advanced web interface.

Show 6 more labels / short text on this page
Alarm Troubleshooting · Cause Solution · Cause Solution · Cause Solution · Cause Solution · Cause Solution
Page 89 of the Graco Diaphragm Pump (312776F) user manual — E-19: I/O ALARM
Page 89 · click to enlarge
Page 89

Table 11. Alarm Troubleshooting

E-19: I/O ALARM

The Mix and Purge digital inputs are on at the same time. Ensure that only one input is on at a time. At least 1 sec

delay is required when switching from Mix to Purge or vice versa.

Fluid Plate Reboot (FP Reboot): Occurs if the system detects a fluid plate control board reboot or power cycle not triggered from the EasyKey. The system reverts to Recipe 61, and mixed material may be in the lines.

Flush the system or perform a color change. If possible, identify the origin of the reboot or power cycle.

Autokey Lost: Occurs if the Autokey is lost or changed after having been detected. (A short term loss of the Autokey will not be registered.) Some system functions may become unavailable. For example, an automatic system will not respond to PLC or robot control.

Reinstall the Autokey, or verify that the Autokey is set properly.

Illegal Source: Occurs if a recipe outside of the range 1-60 is detected as the source data for global recipe data copies. This is possible if an invalid configuration file is sent to the EasyKey.

Verify that the source data is from a valid recipe (1-60).

2K/3K Error: Occurs if the recipe data is incompatible with the current Autokey setting (2K or 3K). This is possi- ble if the Autokey is changed or an invalid configuration file is sent to the EasyKey.

Verify that the Autokey is set properly or that the configu- ration file is valid.

Init Error: Occurs if the recipe data codes specifying the type of machine they were made on are not what is expected. For example, a 3KS machine receives a con- figuration file originally made on a 2KS machine.

Verify that the configuration file is valid.

Config Error: Occurs if a configuration file sent to the EasyKey specifies a different hardware setup than what exists. For example, the configuration file specifies 2 color change boards but only 1 is present.

Verify that the configuration file specifications and the hardware conform.

Range Error: Occurs if a valve used in a recipe is not present in the current hardware setup. For example, a recipe calls for valve 30 but the system has only 12 valves.

Verify that the recipe specifications and the hardware conform.

Level Control (LC) Error: Occurs if level control data is received by the EasyKey, and the current Autokey set- ting (2K or 3K) has changed since the level control data was originally initialized.

Verify that the Autokey is set properly.

Level Control (LC) Range Error: Occurs if level control data includes a valve range exceeding the capability of the machine.

Set level control data correctly.

Modbus (MB) Overflow: Occurs if the Modbus connec- tion to a PLC experiences data overflow.

Verify the Modbus protocol to the EasyKey.

Alarm Troubleshooting · Cause Solution

Page 90 of the Graco Diaphragm Pump (312776F) user manual — E-21: MATERIAL FILL ALARM
Page 90 · click to enlarge
Page 90

Table 11. Alarm Troubleshooting

E-20: PURGE INITIATE ALARM

System detects atomizing air to the gun when purge is selected.

Shut off gun air.

For systems with a gun flush box, gun is not in the box when purge is selected.

Place gun in gun flush box. Verify that gun flush box is operating properly.

For systems with auto dump on, gun is not in the box when auto dump is initiated.

Place gun in gun flush box. Verify that gun flush box is operating properly.

For systems with a gun flush box, Fuse F2 is blown. Verify condition of fuse and replace if necessary. See Repair-Parts manual.

E-21: MATERIAL FILL ALARM

For systems with minimum mixed material fill volume entered, the system detects that fill volume is not achieved during mixed material fill time.

Check for restrictions or leaks in the fluid supply system.

Check if the fill volume is properly configured:

  • Adjust fill volume.
  • Adjust fill time.

For systems without color change and with minimum mixed material fill volume entered, Fuse F1 is blown.

Verify condition of fuse and replace if necessary. See Repair-Parts manual.

E-22: TANK A LOW ALARM, E-23: TANK B LOW ALARM, or E-24: TANK S LOW ALARM

The tank volume reaches the low-level threshold. The EasyKey screen will display the alarm and prompt the user to do one of the following:

  • Refill tank volume to clear the alarm.
  • Resume mixing by selecting “Spray 25% of remaining volume.” If this selection is chosen, a second alarm will occur after 25% of the remaining volume is mixed. Refill tank volume to clear the alarm.
Show 4 more labels / short text on this page
Alarm Troubleshooting · Cause Solution · Cause Solution · Cause Solution
Page 91 of the Graco Diaphragm Pump (312776F) user manual — E-28: MIX FILL PUSH COMPLETE
Page 91 · click to enlarge
Page 91

Table 11. Alarm Troubleshooting

E-25: AUTO DUMP COMPLETE ALARM

A potlife alarm is active for more than 2 minutes, the gun flush box is enabled and gun is in the gun flush box, and an auto dump flush sequence is complete.

Be sure to spray all mixed material before potlife expires.

E-26: COLOR/CATALYST PURGE ALARM

System detects no meter pulses, or a disruption in meter pulses lasting longer than 1 second throughout the Color/Catalyst purge time duration.

Check that meter cable is connected.

Clean or repair meter.

E-27: COLOR/CATALYST FILL ALARM

System detects no meter pulses, or system must detect at least 10cc of material from each side throughout the Color/Catalyst fill time duration.

Check that meter cable is connected.

Clean or repair meter.

Gun, dump valve, or correct color/catalyst valve not open.

Open the valve.

Exhausted fluid supply. Check fluid level and refill if necessary.

Switch settings (S3-S6) on color change board do not match hardware configuration.

Verify that color change board switches are set correctly. See installation manual.

Fuse F1, F2, or both are blown. Verify condition of fuses and replace if necessary. See Repair-Parts manual.

E-28: MIX FILL PUSH COMPLETE

Mix fill push has been completed. Potlife expired material has been purged.

Show 5 more labels / short text on this page
Alarm Troubleshooting · Cause Solution · Cause Solution · Cause Solution · Cause Solution
Page 92 of the Graco Diaphragm Pump (312776F) user manual — 4-WAY SOLENOID
Page 92 · click to enlarge
Page 92

Schematic Diagrams

System Pneumatic Schematic

COLOR CHANGE CONTROL

COLOR VALVE STACKS

MANIFOLD AIR EXHAUST MUFFLER

COLOR 1 COLOR 2 COLOR 3 COLOR 4 COLOR 5 COLOR 6 COLOR 7 COLOR 8 COLOR SOLVENT COLOR 9 COLOR 10 COLOR 11 COLOR 12 CATALYST 1 CATALYST 2 CATALYST 3 CATALYST 4 CATALYST SOLVENT

TO MANIFOLD 1/4 TUBE

12 VDC

FLUSH AIR TO FLUID INLET 1/4 TUBE

CLOSE

OPEN 5/32 TUBE

DOSE A VALVE

4-WAY SOLENOID

A B

12 VDC

CLOSE

OPEN 5/32 TUBE

DOSE B VALVE

4-WAY SOLENOID

A B

12 VDC

CLOSE

OPEN 5/32 TUBE

PURGE A VALVE

4-WAY SOLENOID

A B

3/8 AIR FILTER MANUAL DRAIN 5 MICRON WALL MOUNT ONLY

CONTROL AIR

12 VDC

CLOSE

OPEN 5/32 TUBE

PURGE B VALVE

COLOR 13 COLOR 14 COLOR 15 COLOR 16 COLOR 17 COLOR 18 COLOR 19 COLOR 20 COLOR 21 COLOR 22 COLOR 23 COLOR 24 COLOR 25 COLOR 26 COLOR 27 COLOR 28 COLOR 29 COLOR 30

4-WAY SOLENOID

A B

AIR INPUT

12 VDC

PURGE C VALVE (OPTIONAL) 4-WAY SOLENOID

CLOSE

OPEN 5/32 TUBE

A B

AIR EXHAUST MUFFLER

PURGE AIR

12 VDC

5/32 TUBE

DUMP A VALVE (OPTIONAL)

3-WAY SOLENOID

A

OPEN

AIR INPUT

12 VDC

OPEN 5/32 TUBE

DUMP B VALVE (OPTIONAL)

3-WAY SOLENOID

A

MAC 36 SERIES SOLENOID VALVES

12 VDC GFB 1 VALVE (OPTIONAL)

5/32 TUBE

3-WAY SOLENOID

A

OPEN

12 VDC GFB 2 VALVE (OPTIONAL)

OPEN 5/32 TUBE

3-WAY SOLENOID

A

MANIFOLD

Schematic Diagrams

Page 93 of the Graco Diaphragm Pump (312776F) user manual — J10
Page 93 · click to enlarge
Page 93

System Electrical Schematic

Non-Hazardous Area

NON-HAZARDOUS AREA

OPERATOR INTERFACE

LINE FILTER

L1 N GND

L1 N

DC OK

+24 VDC

+ + - -

POWER SUPPLY

1 2 L1 N

85-250 VAC

L1 N GND

TERMINAL BLOCK

L1 N GND

COMMON

COMMON

GND LUG

GND N L1

OPEN OPEN

85-250 VAC

POWER ROCKER SWITCH 1 2 3 4 5

1 2 1A 1B 2A 2B

POWER HARNESS

UNUSED UNUSED UNUSED UNUSED UNUSED

J1

HARNESS

1 2 3 J5

+12VDC I/S (RED) COM (BLACK) SHIELD

BARRIER BOARD

CABLE

1 2 3 J4

+24VDC OPEN COMMON

(50' STD.)/

(100' OPTION)

ALARM

J4

DISPLAY BOARD

MEMBRANE SWITCH WITH RIBBON CABLE

1 2 3 4 5 6 7 8 9 10 11

1 2 3 4

J9

1 2 3 4 5 6

MIX INPUT PURGE INPUT JOB COMPLETE INPUT EXTERNAL CLR CHG READY RESET ALARM INPUT DIGITAL INPUT COMMON

RJ45

RJ45

J6

J2

POWER DIST. TERMINAL BLOCKS

RJ45 RJ45

1 2 3 4 5 6 7 8

DIGITAL INPUT COMMON RECIPE BIT 0 INPUT RECIPE BIT 1 INPUT RECIPE BIT 2 INPUT RECIPE BIT 3 INPUT RECIPE BIT 4 INPUT RECIPE BIT 5 INPUT RECIPE CHANGE INPUT

J3

J2

REMOTE I/O INTEGRATION BOARD

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

DISPLAY

1 2 3 4 5 6 7 8

DIGITAL OUTPUT COMMON/POWER PURGE/RECIPE CHG ACTIVE OUTPUT MIX ACTIVE OUTPUT MIX READY OUTPUT FILL ACTIVE FLOW CAL. ACTIVE FLOW RATE ALARM OUTPUT DIGITAL OUTPUT COMMON/POWER

SHIELD

J4

1 2 3 4 5 6 7 8 9 10

FLOW CONTROL CAL. (BLK) GUN TRIGGER (WHT) DIGITAL IN COMMON (RED) REMOTE STOP (GRN) ALARM RESET (BRN) ALARM OUTPUT (BLU) DIGITAL OUTPUT COMMON (ORG) POT LIFE (YEL) FLOW RATE ANALOG IN (PUR) FLOW RATE ANALOG COMMON (GRAY)

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6

DIGITAL OUTPUT COMMON/POWER SPECIAL OUTPUT #1 SPECIAL OUTPUT #2 SPECIAL OUTPUT #3 SPECIAL OUTPUT #4 DIGITAL OUTPUT COMMON/POWER

J5

J5

I/O HARNESSES

BEACON (+24) YEL (COM) GRAY

ORG

TERMINAL BLOCKS

BRN RED

1 2 3 4 5 6

RS485 INTEGRATION A (WHT/BLU) RS485 INTEGRATION B (BLU/WHT) RS485 INTEGRATION GROUND (SHIELD) RS485 NETWORK A (WHT/ORG) RS485 NETWORK B (ORG/WHT) RS485 NETWORK GROUND (SHIELD)

1 2 3 4 5 6

J10

CABLE

J7 J8

FO IN (BLK) FO OUT (BLU)

RJ45 RJ45 P1

RJ45 BULKHEAD

3' (25'-200' OPTIONS)

RJ45 RJ45

WEB SERVER

MODULE

Show 9 more labels / short text on this page
Schematic Diagrams · + - · + - · 3' · + · + · + · + · 3'
Page 94 of the Graco Diaphragm Pump (312776F) user manual — AIR FLOW SWITCH 1
Page 94 · click to enlarge
Page 94

System Electrical Schematic

Hazardous Area

FLUID PANEL CONTROL BOX

HAZARDOUS AREA

3X CABLE

FLUID PANEL CONTROL BOARD

1 2 3 4 5 6

PWR (RED) COM (BLACK) SIG (WHITE) SHIELD/GRN PWR (RED) COM (BLACK) SIG (WHITE) SHIELD/GRN PWR (RED) COM (BLACK) SIG (WHITE) SHIELD/GRN

FLOW METER A

J3

FLOW METER B

I.S. METERS

1 2 3 4 5 6

FLOW METER SOLVENT

J12

J2

1 2 J1

SIG (RED) COM (BLK)

TECNO V/P

1 2 3 4 5

FLOW CONTROL BOARD

GROUND TERMINAL

V/P ANALOG OUT (WHT) PRESS. (GRN) +12 V (RED) GND (BLK) CHASSIS (BARE)

1 2 3 4 5 6

UNUSED

1 2 3 4 5

J4

+ PRESSURE (GRN) COM (RED) EX+ (WHT) - PRESSURE (BLK) SHIELD (BARE)

FLUID PRESS. SENS.

J10

J13

+12VDC I/S COM SHIELD

1 2 3 4 5 6

J5

MH2

J7/J11

1 4 5 2 3

COLOR BOARD 1 (COLORS 1 THRU 12, CATALYST 1 THRU 4)

6' STD. (3'-100' OPTIONS)

3 2 5 4 1

GRD (BLK) +12VDC (RED) SHIELD (BARE) CAN H (WHT) CAN L (BLU)

J11

MANIFOLD 6 5 4 3 2 1

MANIFOLD

+12VDC

1 2 3 4 5 6

COM +12VDC

CLR 9

CLR 8

COM +12VDC

COM +12VDC

CLR 7

COM +12VDC

J8

J9

CLR 10

50' STD.

BOOTH CONTROL BOARD

CLR 6

COM +12VDC

CLR 11

3 2 5 4 1

GRD (BLK) +12VDC (RED) SHIELD (BARE)

3 2 5 4 1

COM

J7

CLR 5

+12VDC

1 2 3 4 5 6

6 5 4 3 2 1

COM +12VDC

CLR 12

CAN H (WHT)

CLR 4

COM +12VDC

J15

J16

COM +12VDC

CAN L (BLU)

COM +12VDC

CAT 4

CLR 3

COM

COM +12VDC

CAT 3

6 5 4 3 2 1

COM +12VDC

CAT 2

CLR 2

+12VDC

COM +12VDC

1 2 3 4 5 6

MANIFOLD 6 5 4 3 2 1

CLR 1

J14

J10

COM +12VDC

CAT 1

BLACK RED BLACK RED BLACK RED

DUMP B

COM +12VDC

COM +12VDC

SOL CAT

SOL CLR

COM

J8

GFB #1

3-WAY SOLENOID

1 4 5 2 3

J7/J11

GFB #2

6' STD.

BLACK RED BLACK RED BLACK RED

12 VDC

J7/J11

6 5 4 3 2 1

DUMP A

1 4 5 2 3

COLOR BOARD 2 (COLORS 13 THRU 30)

J15

MANIFOLD

NOT USED

PURGE C

6 5 4 3 2 1

BLACK RED BLACK RED BLACK RED

PURGE B

MANIFOLD

MANIFOLD 6 5 4 3 2 1

4-WAY SOLENOID

CLR 21

+12VDC

1 2 3 4 5 6

COM +12VDC

CLR 22

J14

PURGE A

CLR 20

COM +12VDC

J8

J9

COM +12VDC

COM +12VDC

CLR 23

NOT USED

12 VDC

CLR 19

COM

COM +12VDC

CLR 24

+12VDC

1 2 3 4 5 6

6 5 4 3 2 1

BLACK RED BLACK RED BLACK RED

NOT USED

CLR 18

COM +12VDC

6 5 4 3 2 1

COM +12VDC

CLR 25

CLR 17

COM +12VDC

J15

J16

COM +12VDC

CLR 26

J9

DOSE B

CLR 16

COM +12VDC

COM

CLR 27

DOSE A

+12VDC

1 2 3 4 5 6

6 5 4 3 2 1

COM +12VDC

CLR 28

CLR 15

COM +12VDC

1 2 3 4 5 6 7 8 9 10

SIG COM SIG COM SIG COM SIG COM SIG COM

AIR FLOW SWITCH 1

CLR 14

COM +12VDC

J14

J10

COM +12VDC

CLR 29

CLR 13

COM +12VDC

CLR 30

AIR FLOW SWITCH 2

COM

FO OUT (BLU)

J1

SOLVENT FLOW SWITCH

J4

GFB 1 PRESSURE SWITCH

FO IN (BLK)

J6

GFB 2 PRESSURE SWITCH

Schematic Diagrams · (10')/ (40')

Page 95 of the Graco Diaphragm Pump (312776F) user manual — TERMINAL BLOCKS POWER
Page 95 · click to enlarge
Page 95

EasyKey Electrical Schematic

TERMINAL BLOCKS POWER

GND

N

GRN/YEL 16 AWG

RED 16 AWG

BROWN 16 AWG

GND

N

LINE FILTER

N

ALARM

BROWN 16 AWG

RED 16 AWG

ROCKER SWITCH

1A

2A

RED 16 AWG

BROWN 16 AWG

RJ45 RJ45 BULKHEAD

N

N

VOLTAGE

HIGH

IN

POWER SUPPLY

24 VDC+ OUTPUT

GND LUG

COMMON

24 VDC+

DC OK

BLACK 18 AWG

RED 18 AWG

IS POWER

12 VDC

+12 VDC I/S (WHITE)

COMMON (BLACK)

BLACK 18 AWG

RED 18 AWG

SHIELD/GRND

UNUSED

UNUSED

UNUSED

UNUSED

UNUSED

J4-3

J4-2

J4-1

J1-5

J1-4

J1-3

J1-2

J1-1

J5-3

J5-2

J5-1

GREEN/BLACK/WHITE 22 AWG

RED/BLACK/WHITE 22 AWG

J1

J5

BLACK 18 AWG

RED 18 AWG

24 VDC+ IN

RJ45 RJ45

J4

DISPLAY BOARD

BARRIER BOARD

P1

J9

DISPLAY BOARD

Show 7 more labels / short text on this page
Schematic Diagrams · + · + · + · + · + · +
Page 96 of the Graco Diaphragm Pump (312776F) user manual — Flow Rate (cc/min)
Page 96 · click to enlarge
Page 96

Meter Performance Data (G3000 on A and B)

Meter Performance Data (G3000 on A and B)

1:1 2:1 3:1 4:1 5:1 6:1 7:1 8:1 9:1 10:1 11:1 12:1 13:1 14:1 15:1 16:1 17:1 18:1 19:1 20:1 21:1 22:1 23:1 24:1 25:1 26:1 27:1 28:1 29:1 30:1

50cc Dose

25cc Dose

Ratio

10cc Dose

Valve Setting1.25 Turns Open (standard setting)
A and B Feed Pressure300 psig
Viscosity65.7 centipoise
Ratio Tolerance5%
FluidHydraulic Oil

Flow Rate (cc/min)

Test Conditions

Page 97 of the Graco Diaphragm Pump (312776F) user manual — Flow Rate (cc/min)
Page 97 · click to enlarge
Page 97

Meter Performance Data (G3000 on A, Coriolis on B)

Meter Performance Data (G3000 on A, Coriolis on B)

1:1 2:1 3:1 4:1 5:1 6:1 7:1 8:1 9:1 10:1 11:1 12:1 13:1 14:1 15:1 16:1 17:1 18:1 19:1 20:1 21:1 22:1 23:1 24:1 25:1 26:1 27:1 28:1 29:1 30:1

50cc Dose

25cc Dose

10cc Dose

25cc Dose

Ratio

50cc Dose

Valve Setting1.25 Turns Open (standard setting)
A and B Feed Pressure300 psig
Viscosity65.7 centipoise
Ratio Tolerance5%
FluidHydraulic Oil

Flow Rate (cc/min)

Test Conditions

Page 98 of the Graco Diaphragm Pump (312776F) user manual — Technical Data
Page 98 · click to enlarge
Page 98

Technical Data

Maximum fluid working pressure Base system: 4000 psi (28 MPa, 280 bar)

Low pressure color change: 300 psi (2.1 MPa, 21 bar) High pressure color change: 3000 psi (21 MPa, 210 bar) Coriolis meter: 2300 psi (16.1 MPa, 161 bar) Maximum working air pressure 100 psi (0.7 MPa, 7 bar) Air supply 75 - 100 psi (0.5 - 0.7 MPa, 5.2 - 7 bar) Air filter inlet size 3/8 npt(f) Air filtration for air logic and purge air (Graco-supplied). . 5 micron (minimum) filtration required; clean and dry air Air filtration for atomizing air (user-supplied) 30 micron (minimum) filtration required; clean and dry air Mixing ratio range 0.1:1- 50:1* On-ratio accuracy up to + 1%, user selectable Fluids handled one or two component:

  • solvent and waterborne paints
  • polyurethanes
  • epoxies
  • acid catalyzed varnishes
  • moisture sensitive isocyanates Viscosity range of fluid . . . . . . . . . . . . . . . . . . . . . . . . . . . 205000 cps* Fluid filtration (user-supplied). . . . . . . . . . . . . . . . . . . . . . 100 mesh minimum Fluid flow rate range*
75. 3800 cc/min. (0.02-1.00 gal./min.) 38 - 1900 cc/min. (0.01-0.50 gal./min.) 20 - 3800 cc/min. (0.005-1.00 gal./min.) 38 - 1900 cc/min. (0.01-0.50 gal./min.) Fluid inlet sizes

G3000, G250 Meter G3000HR, G250HR Meter Coriolis Meter S3000 Solvent Meter (accessory)

1/4 npt(f) 1/4 npt(f) Fluid outlet size (static mixer) 1/4 npt(f) External Power Supply Requirements 85 - 250 Vac, 50/60 Hz, 2 amps maximum draw

Flow Meter Dose Valve/Color Valve Adapters

15 amp maximum circuit breaker required 8 to 14 AWG power supply wire gauge Operating temperature range 41- 122° F (5-50° C) Environmental Conditions Rating indoor use, pollution degree (2), installation category II Noise Level

below 70 dBA below 85 dBA Wetted parts 303, 304 SST, Tungsten carbide (with nickel binder),

Sound pressure level Sound power level

* Dependent on programmed K-factor and application. The maximum allowable flow meter pulse frequency is 425 Hz (pulses/sec). For more detailed information on viscosities, flow rates, or mixing ratios, consult your Graco dis- tributor.

See individual component manuals for additional technical data.

Technical Data · perfluoroelastomer; PTFE

Page 99 of the Graco Diaphragm Pump (312776F) user manual — Graco Information
Page 99 · click to enlarge
Page 99

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com

For patent information, see www.graco.com/patents

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Original instructions. This manual contains English. MM 312776

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea
  • GRACO INC. AND SUBSIDIARIES
  • P.O. BOX 1441
  • MINNEAPOLIS MN 55440-1441
  • USA

Copyright 2008, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com Revision F, April 2015

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
E-1Communication Error Alarm p.80
E-2Potlife Alarm p.80
E-3Ratio High Alarm p.80
E-4Ratio Low Alarm p.80
E-5Overdose A/B Dose Too Short Alarm p.80
E-6Overdose B/A Dose Too Short Alarm p.80
E-7Dose Time A Alarm p.80
E-8 E-9Dose Time B Alarm Not used p.80
E-10Remote Stop Alarm p.80
E-11Purge Volume Alarm p.80
E-12CAN Network Communication Error Alarm p.80
E-13High Flow Alarm p.80
E-14Low Flow Alarm p.80
E-15System Idle Warning p.80
E-16Setup Change Warning p.80
E-17Power On Warning p.80
E-18Defaults Loaded Warning p.80
E-19I/O Alarm p.80
E-20Purge Initiate Alarm p.80
E-21Material Fill Alarm p.80
E-22Tank A Low Alarm p.80
E-23Tank B Low Alarm p.80
E-24Tank S Low Alarm p.80
E-25Auto Dump Complete Alarm p.80
E-26Color/Catalyst Purge Alarm p.80
E-27Color/Catalyst Fill Alarm p.80
E-28Mix Fill Push Complete p.80
E-8gun trigger input is active (AFS or Integration) and fewer than 31 B meter pulses were detected during the p.85
E-9Not used p.86

Ask about the Graco Diaphragm Pump (312776F)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco Diaphragm Pump (312776F)

Be the first to ask — other owners or our team will answer.

Original document

Graco Diaphragm Pump (312776F) manual PDF

99 pages·4.5 MB·Webcam·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…