Matrix Meter
Used to dispense petroleum-based lubricants and antifreeze only.
Part No. 246008 Series D, North America (N. A.) Part No. 249881 Series D, Australia
1500 psi (10.3 MPa, 103 bar) Maximum Working Pressure
600 psi (4.1 MPa, 41.4 bar) Maximum Dynamic Working Pressure (while dispensing)
5 gpm (18.9 lpm) Maximum Flow Rate

This dispense valve is:
The Matrix Meter contains an RF device with the following approvals:
Industry Canada Statement The term “IC” before the certification/reg- istration number only signifies that the In- dustry Canada technical specifications were met.


The following warnings include general safety information for this equipment. More specific warnings are included in the text where appropriate.

Graco recommends that meters be programmed prior to installation.
For ease of installation be sure to tag each meter with the corresponding PC meter number from the Matrix software. For example: Bay 1, 10W30. These tags are used for locating the corresponding meter in the assigned bay or location.

The electronic meter batteries need to be charged prior to use. See Instruction Manual 309502 for details.
Prior to programming the electronic meters,
The meter must be at the ACTIVATE/ACTIVATE screen for it to be programmed. If you are in Work Order mode, put a test Work Order into the system so you can navigate to the ACTIVATE/ACTIVATE meter screen and re-program.
METER ID is the RF address assigned to the meter by the PC during programming.
Programming the Meter


The PC software allows a 5 minute period to pro- gram the meter.
If the electronic meter is unable to communicate with the PC during programming, the message NO SIGNAL appears at the top of the meter display.
6. Once the information is programmed into the elec- tronic meter, the meter can be connected to the dis- pensing hose in the corresponding bay. If the meter will not be immediately connected temporarily label it with the corresponding meter number and location (i.e. Meter 1, Bay 1, 10W30). The label assures the correct meter is installed in the correct location in the system. After the meter is installed in the correct location, the label can be removed. See Meter Installation on page 6.
If PC software revision is 2.01.29 or meter firmware revision is 2.00.053, meter will display 3 places to the right of the decimal rather than 2.
If a programmed meter is moved or if the pro- grammed parameters need to be changed, the meter must be reprogrammed.
Programming the Meter


Failure to comply with the following installation requirements may result in warranty coverage being denied.
H
* Do not use diaphragm pumps in a Matrix system.
† Special pump packages are required for anti- freeze. See instruction manual 310650.
Programming the Meter · ti5127


Mounting bracket kit 249440 is available for resting a Matrix meter on a console. See FIG. 5.

M
K
N
Mounting bracket 15B750 is available for resting a Matrix meter on a 16 gallon drum. See FIG. 6.

Programming the Meter · ti6733 · ti6732

Pre-installation Procedure
Contaminated lines could cause the valve to leak. Failure to flush may result in warranty coverage being denied. See CleanLine Filtration System, Instruction Manual 310652.
The Matrix meter must be powered, nozzle open (counter clockwise), and in dispense mode for fluid pressure to be relieved.
The system must be properly grounded. Read warn- ings, page 3. Refer to the user manuals for the pump and other system components, and ground the follow- ing:
Programming the Meter

Graco recommends using PTFE tape on hose threads prior to installing the Matrix meter. PTFE tape should be after the leading thread and clockwise (same direc- tion as meter installs on hose fitting). Caution should be taken not to get tape into the meter during installa- tion as this can cause the meter to malfunction. Should the tape be the cause of the malfunction, Graco warranty will be denied.

101, 204, or 303
102, 202, or 302

40 wrench tighten to prevent leakage
Slide boot onto hose before connecting hose 1
Improper grounding can cause a hazardous condition and result in fire or explosion. Follow instructions in step 2 to maintain grounding continuity.
Programming the Meter · ti64317

Asleep / Awake Mode
Battery Life Indicator
Asleep is a battery-saving mode in which the display goes blank after two minutes of inactivity during normal operation. The display comes Awake from sleep mode when any button is pressed.
On the right side of the display is a series of four bars located under the word BATT. See FIG. 11. The pres- ence of all four bars indicates a fully charged battery. The bars decline in number as the meter is used and the battery discharges. All Matrix meter batteries should be re-charged at the end of the working day to assure good performance the next work day.
The electronic meter dispenses fluids at two different rates.
As the trigger is partially engaged, the flow rate is low and is indicated by two bars on the display. See FIG. 9.



Meter Operation

When the meters were originally programmed by the system administrator, one of the following security choices was entered:
2122 ENTER
Prior to dispensing, it may be necessary to complete one of the following security procedures, depending on the security mode selected.
When set for system monitoring, no security authoriza- tion is required by the operator. However, any amount of fluid dispensed is automatically sent by the meter to the PC where it is recorded for future reference.
Parts Room Authorization
PIN Code (personal identification number) means that a four digit PIN code must be entered at the meter to obtain dispense authorization. To use a meter with PIN code security:
This mode provides high level security and requires a Parts Room Administrator to authorize each dispense.
REQUIRED AUTHORIZATION
REQUIRED
REQUEST APPROVAL
REQUEST APPROVAL
REQUEST APPROVAL
Meter Operation

When the meters were programmed by the System Administrator, one of the two Work Order processing methods below was selected.
Work Orders are a maximum of (12) characters and the Job Number is a maximum of (3) characters. The Work Order number is separated from the Job Number with a dash (-).
ENTER NEW 2ACO - 32567 - IC9 2AC03 - 458A1 - 2233A -
ENTER NEW 2ACO - 32567 - IC9 2AC03 - 458A1 - 2233A -
The characters A-Z, 0-9, dash (-); forward slash (/), period (.), or space can be used when assigning a Work Order or Job Number. One Work Order can have more than one service using an extension in the order number (i.e., 123456.oil, 123456.atf). The meter can receive up to five (5) work orders at a time. See FIG. 14.
Assigning Work Orders and Job Numbers from the PC
Work Orders and Job Numbers are assigned to a meter from the PC using the “Entering Work Orders” button in the software. This feature is password protected.
If the Work Order is not received by the meter, a pop-up box appears indicating that the Work Order could not be sent to the assigned meter. You then can click Retry or Cancel.
2AC03
WORKORDER JOB
RIGHT LEFT
Assigning Work Orders and Job Numbers at the Meter
Work Orders and Job Numbers can be assigned at the meter using the meter Work Order screen and meter keypad buttons. The screen shows previously assigned Work Orders and the Enter New option.
To enter a new Work Order follow the procedure below:
Meter Operation

The Emergency Code Number must be provided by the system administrator before performing this procedure.
To Cancel a Work Order press either the right or left keypad button on the meter until the cursor underlines the Cancel option. Push the up arrow on the keypad to cancel the Work Order entry. This will take you back to the first Work Order/Job Num- ber screen.
Work Order Validation Mode: The default operation mode for either work order method is validation mode. This mode is recommended for maximum protection against unauthorized dispenses and maximum integrity of the Matrix database.
If the communication link is lost (power loss, computer crash), the meters will continue to function if they are placed in the Emergency Mode.
After the meter is placed in Emergency Mode, the battery must remain in the meter until the display goes blank. If not, the meter will revert to it’s origi- nal programming.
During Emergency Mode, the meter continues to store dispense history and will communicate this information to the PC when the communication link is restored.
1222 ENTER
RIGHT LEFT
Meter Operation

Preset Dispense Mode
The meter dispense options are determined by the sys- tem administrator at the time the meter is programmed. Meter dispense options include:
Meters programmed in preset mode count down from a specified value to zero and shut off automatically. The preset value can be increased or decreased from the ini- tial value using the up and down keypad buttons.
To change the meter from one mode to another, you must reprogram the meter. See Programming the Meter on page 4.

To dispense fluids in this mode:
If END is not pressed, after five minutes the meter will automatically end the job and log the dispense to the PC.
Flow can be stopped at any time during the dispense by pressing the meter trigger or any button on the meter display.
An appropriate preset amount can be set for each work order when entering work orders at the PC.
Once the preset amount is dispensed, the meter display automatically changes to read TOP OFF MODE. This allows the operator to add additional fluid after the pre- set amount is dispensed. The Top Off amount to be dis- pensed can be limited during meter programming. See FIG. 18.
Meter Operation


If the meter displays a low battery warning, wait 30 seconds before installing a new battery. See Bat- tery Life Indicator page 10.


If END is not pressed, after 5 minutes the meter will time out and log the dispense to the PC.
The nozzle opens and closes with LESS THAN one turn.
When meters are programmed in restricted preset mode, the specified dispense value cannot be increased, only decreased. The functionality of this fea- ture is identical to Preset Dispense Mode (see Preset Dispense Mode beginning on page 14) except that the preset value can only decreased with the down keypad button.

Meter Operation

Relieve pressure before you check or repair the meter. Follow the Pressure Relief Procedure, page 8. Be sure all other valves and controls and the pump are operating properly. If using the chart below to trouble- shoot is not successful, contact your Graco distributor for repairs or component replacement.
Read warnings, page 3.
Battery display bars do not appear.
Battery has low charge. Recharge battery.
Meter display does not activate.
Battery is dead. Attempt to recharge a dead battery using procedures outlined in the Battery Charger Instruction Manual (309502). If procedure does not restore a normal charge, replace the battery.
Battery inserted too soon. Wait 30 seconds and reinstall fully charged battery.
Cable connections are loose or dis- connected.
Ensure cables are properly connected. See page 22.
Electronic display is damaged. Replace with Bezel Repair Kit (246438). See page 33.
Slow or no fluid flow from meter.
CleanLine filter system is clogged. Clean or replace the CleanLine filter. Refer to the Clean- Line Filter System Instruction Manual (310652).
Meter is not in dispense mode. See dispense options, page 14.
Matrix meter filter is clogged. Clean or replace the Matrix meter filter element. See Cleaning or Replacing the FIlter page 21.
Pump pressure is low. Turn up air pressure to the pump. SeeTechnical Speci- fications page 35.
Pump or reel fluid shut-off valve is not fully open.
Fully open pump or reel fluid shut-off valve.
Meter hydraulic valve is not function- ing.
If meter bars are lit indicating flow, the nozzle tip is fully open, and the fluid flow has been verified to the meter valve inlet, then the meter hydraulic valve has failed and the meter should be replaced.
Electronic board connections may be loose or disconnected.
Verify that all connectors are connected or re-seated to the board connections. See page 22.
Trigger membrane switch is dam- aged - flow bars DO NOT show on the meter display when the trigger IS actuated.
Replace the trigger membrane using the Trigger Repair Kit (246439 N. A., 249883 Australia). See page 33.
Meter valve is blocked with debris - flow bars DO show on the meter dis- play when trigger IS actuated.
Flush the valve with mineral spirits at high pressure and flow. Warning: do not exceed the maximum working pressure of the meter (1500psi - 103 bar).
Quick close nozzle is closed. Open nozzle, see FIG. 21 on page 15.
A hydraulic quick disconnect was used to connect the meter to the dis- pense hose, allowing debris to clog meter.
Quick disconnects should not be used with Matrix prod- uct, doing so voids the warranty.
Troubleshooting · Problem Cause Solution

Meter does not stop dispensing.
Meter valve is blocked with debris - flow bars DO NOT show on the meter display when the trigger IS NOT actu- ated.
Flush the valve with mineral spirits at high pressure and flow. Warning: Do not exceed the maximum working pressure of the meter (1500 psi - 103 bar). If flushing does not resolve the problem, the meter should be replaced.
Trigger or trigger membrane switch is damaged - flow bars DO show on the meter display when the trigger IS NOT actuated.
Replace the trigger and trigger membrane using the Trigger Repair Kit (246439 N. A., 249883 Australia). See page 33. Do not use clamps or wire ties to hold trigger during dispense, doing so voids the warranty.
Dynamic System Pressure (while dis- pensing) exceeds the recommended 600 psi (4.1 MPa, 41.4 bar).
Reduce system pressure. A lower ratio pump may be required to reduce pressure and maintain sufficient flow.
A hydraulic quick disconnect was used to connect the meter to the dis- pense hose, allowing debris to block meter.
Do not use quick disconnects with Matrix product. Use of quick disconnects voids the warranty.
Displayed dis- pensed amount is not accurate.
Meter is not programmed for the cor- rect fluid type.
Verify meter programming.
Meter gears are worn. Meter requires calibration due to wear. See page 19.
Meter will not take work orders.
Battery has low charge or is dead. Recharge battery.
Battery inserted too soon. Wait 30 seconds and reinstall fully charged battery.
Meter may not be programmed. Reprogram meter.
Battery may have been pulled during programming.
Reprogram meter.
Two meters may be programmed as the same meter.
Ensure each meter is programmed individually.
Meter work order list is full. Normal operation. Meter will hold up to 5 work orders.
Meter has intermit- tent or no RF com- munication.
Meter is outside RF communication range of transceiver.
Reposition transceiver or add a transceiver.
Two meters may be programmed as the same meter.
Ensure each meter is programmed individually.
PC or transceiver is off. Turn PC on, open Matrix application, and check power on transceiver.
Meter will not pro- gram.
Incorrect COM port selected for transceiver connection.
Change to correct COM port at the PC in Matrix trans- ceiver configuration screen.
Transceiver is not powered up. Power up transceiver, wait 30 seconds or until red lights go blank and green light remains on alone.
Transceiver dip switches are not set for the communication cable being used.
See transceiver manual 309498 to set dip switches.
Matrix program is not in programming mode.
Place PC in programming mode. See Programming the Meter, page 4.
The five-minute programming ses- sion has expired.
Place PC in programming mode. See Programming the Meter, page 4.
Network and transceiver settings on the meter are not correctly set.
Make appropriate settings. See Programming the Meter, page 4.
Meter is outside RF communication range of transceiver.
Reposition transceiver or add a transceiver.
Troubleshooting · Problem Cause Solution

Meter has been in service for an extended period of time and begins to work erratically such as loss of Work Orders or Security settings.
E-Prom on meter board has reached the end of its life.
Attempt to reprogram the meter. If you see a pop-up screen on the PC that says, “Memory Failure” and/or the meter screen defaults to the ACTIVATE/ACTIVATE screen, the E-Prom on the meter board must be changed. Install the Electronics Repair Kit (246675). The Electronics Repair Kit includes a new meter board with E-Prom. The meter then can be reprogrammed to the features desired.
Meter leaks. Extension may be loose from meter fluid housing.
Tighten seal nut using two wrenches.
Swivel connection at hose may be leaking.
Clean, seal, and tighten joint.
Meter cuts on and off during preset dispense.
The trigger is being held during pre- set dispense.
Release the trigger during preset dispense.
Trigger or trigger membrane switch is damaged - flow bars DO show on the meter display when the trigger IS NOT actuated.
Replace the trigger and trigger membrane using the Trigger Repair Kit (246439 N. A., 249883 Australia). See page 33. Do not use clamps or wire ties to hold trigger during dispense, doing so voids the warranty.
Meter displays “active trig”
Trigger or trigger membrane switch is damaged - flow bars DO show on the meter display when the trigger IS NOT actuated.
Replace the trigger and trigger membrane using the Trigger Repair Kit (246439). See page 33. Do not use clamps or wire ties to hold trigger during dispense, doing so voids the warranty.
Trigger is being held before activating meter for dispense.
Release trigger to activate meter.
* To use the Matrix Emergency Mode contact the Matrix System Administrator in your facility.
Troubleshooting · Problem Cause Solution

Calculating the Calibration Factor
Use the following tables and formulas to calculate the change to the calibration factor.
Example of Calibration Adjustment for Motor Oil (quarts - 368)
Dispense into a clean, calibrated, volumetric measuring flask until the meter display indicates 1 quart of fluid has been dispensed.
For greater accuracy, submerge the nozzle and let the air settle out of the fluid for ten minutes before noting the volume.
U.S. Measurement Measuring in quarts, and 1 quart is dispensed
Error in Milliliters (ml) Change Calibration
Error in U.S. ounces
Factor by:
(oz.)
Factor by:
+ 50 - 20 + 1.7 - 20
+ 40 - 16 + 1.4 - 16
+ 30 - 12 + 1.0 - 12
+ 20 - 8 + 0.68 - 8
+ 10 - 4 + 0.34 - 4
+ 0 no change 0 no change
- 10 + 4 - 0.34 + 4
- 20 + 8 - 0.68 + 8
- 30 + 12 - 1.0 + 12
- 40 + 16 - 1.4 + 16
- 50 + 20 - 1.7 + 20
The table on the right lists approximate calibration fac- tors for different fluids. Your calibration number may vary slightly due to temperature or flow rate.
Oil (10W-30) 368 389
Gear Lube 375 396
Automatic Transmission Fluid 368 389





The low-battery and dead-battery displays are explained in the Troubleshooting chart on page 16.
The quick-lock nozzle (101, 201, or 301) is not service- able. If the nozzle leaks, replace it as follows. See FIG. 23.
To change the battery see Removing and Replacing the Battery on page 15.
To replace or clean the filter, do the following:

Be sure to position the new filter (9) so the concave side of the screen points downstream. See FIG. 22.


Bezel Repair Kit 246438 is available and can be ordered separately. See the Parts List for the 246008 and 249881 Electronic Meters on page 33. The parts with a ★ next to their reference numbers are included in this repair kit.
When repairing the meter using the Bezel Repair Kit, be sure to use all of the new parts. To replace the parts do the following.
Be sure to use the disposable grounding wrist strap included with the repair kit. Static electricity can dam- age the electrical components as the meter is repaired.
All services to the meter should be done using the right cover half (18) of the meter. If parts should disen- gage as the covers are separated, reposition the parts back into the right cover half (18).

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
42 (both sides)

When reconnecting cable C to the circuit board (112), ensure that the cable is positioned with the white tab facing up and that the cable is straight before push- ing in (closing) the clasp. See FIG. 28.



Ensure that all meter parts are positioned securely and in the correct location. Ensure that all cables are routed correctly throughout the meter and will not be pinched or kinked when the halves are reassembled See FIG. 29 and FIG. 30.
Ensure that the black antenna wire is not posi- tioned between the ribbon cables. Pull antenna away from the cable as shown. See FIG. 31.


If the display does not appear:

Trigger Repair Kits 246439 for meter 246008 and 249883 for meter 249881 are available and can be ordered separately. See the Parts List for the 246008 and 249881 Electronic Meters on page 33. The parts with a ✓ next to their reference numbers are included in this repair kit.
The PSM switch (101) comes attached to the right meter cover half (18). Do not remove it during the meter cover repair procedure.

When repairing the meter using the Trigger Repair Kit, use all of the new parts. To replace the parts do the fol- lowing.
Be sure to use the disposable grounding wrist strap included with the repair kit. Static electricity can dam- age the electrical components within the meter as the repair is completed.

All services to the meter should be done using the right cover half (18) of the meter. If parts should disen- gage as the covers are separated, reposition the parts back into the right cover half (18). See FIG. 33.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.






Ensure that the RF Board (103) is positioned securely in the slots (A) of the new right meter half (18). See FIG. 35.

Ensure that all meter parts are positioned securely and in the correct location. Ensure that all cables are routed correctly throughout the meter and will not be pinched or kinked when the halves are reas- sembled See FIG. 38 and FIG. 39.
Ensure that the circular trigger plunger (23) is cen- tered with the trigger switch. Also ensure that the trigger spring (37) is securely slid into position. See FIG. 36.

Ensure that the black antenna wire is not positioned between the ribbon cables. Pull antenna away from the cable as shown. See FIG. 40.



Electronics Repair Kits 246675 for meter 246008 and 249882 for meter 249881 are available for replacing the Matrix meter electronics. See the Parts List for the 246008 and 249881 Electronic Meters on page 33. The parts with a † next to their reference numbers are included in the Electronics Repair Kit.
When repairing the meter using the Electronics Repair kit be sure to use all of the new parts. To replace the electronics do the following.
The PSM switch (101) comes attached to the right meter cover half (18). Do not remove it during the meter electronics repair procedure.
All services to the meter should be done using the right cover half (18) of the meter. If parts should disen- gage as the covers are separated, reposition the parts back into the right cover half (18). See FIG. 42.

Be sure to use the disposable grounding wrist strap included with the repair kit. Static electricity can dam- age the electrical components within the meter dur- ing the repair.


To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.



When reconnecting cable D be sure that the wires from the valve housing are properly inserted in the valve housing wire retainer hook (G). See FIG. 48.
The two ribs (E) of the new meter cover fit between the two bolts (F) of the meter housing. Be sure not to pinch or crimp the circular switch cable (D) on the new cover half. See FIG. 45.

When reconnecting cable C to the circuit board (112), ensure that the cable is positioned with the white tab facing up and that the cable is straight before push- ing in (closing) the clasp. See FIG. 44.


G
Ensure that all meter parts are positioned securely and in the correct location. Ensure that all cables are routed correctly throughout the meter and will not be pinched or kinked when the halves are reassembled See FIG. 47 and FIG. 48.
Ensure that the black antenna wire is not posi- tioned between the ribbon cables. Pull antenna away from the cable as shown. See FIG. 49.


Make sure that the trigger plunger (23) is centered with the circular trigger switch. Also ensure that the trig- ger spring (37) is slid fully into position. Make sure that all other meter parts are positioned securely and in the correct location. See FIG. 50.


Parts Drawing for the 246008 and 249881 Electronic Meters

23 †✓ 37 †✓ 13 †✓
torque to 20 - 25 ft. lbs
plunger must be inserted fully shouldered against the 6
end of the spring.
apply thread sealant when reassembling
spring must be inserted firmly into trigger with a 7
torque to 7 - 10 in. lbs 3
clockwise screwing motion. When fully assembled
plunger should sit level with the underside surface of the trigger.
remove screws with a T-10 torx driver 4
torque to 3 - 4 in. lbs 8
remove screws with a Phillips screw driver 5

Parts List for the 246008 and 249881 Electronic Meters
Ref. No. Part No. Description Qty. 3† MODULE, control, elec 1 4†✓ SWITCH, PSM, two position 1 6 109018 PACKING, o-ring 1 9 114017 FILTER, 80 mesh 1 11 117310 BATTERY, 9.6V NMH rechargable 1 12†★✓ SCREW, mach, torx, 5-20x1/2 11 13†✓ SPRING, plunger 1 14†✓ SPRING, return 1 18†✓ COVER, valve right 1 19†✓ COVER, valve left 1 22†✓ TRIGGER 1 23†✓ PLUNGER, trigger 1
Ref. No. Part No. Description Qty. 24 15D587 BOOT, rear 1 29 240416 SWIVEL, straight 1 31†★ BEZEL 1 36†✓ PLUNGER, inside trigger 1 37†✓ SPRING, inside plunger 1 40†★✓15D618 GUARD, impact 1 41† SCREW, mach, HD, cross 3 42†★✓ SCREW, phillips 4 43†✓ RING, quad 1 44† WASHER 3
A grounding strap part no. 112190 is included with each of the following kits.
Static electricity can damage the electronic compo- nents within the meter if the grounding wrist strap pro- vided is not used during repair kit service.
★Included in Bezel Repair Kit 246438.
✓Included in Trigger Repair Kit 246439 for meter
246008 or kit 249883 for meter 249881.
† Included in Electronics Repair Kit 246675 for meter
246008 or kit 249882 for meter 249881.

Kit 246005 Nozzle Extension Assembly, rigid 45°

Includes:
Ref. No. Part No. Description Qty.
101 246003 NOZZLE, quick close 1
This same kit is available for antifreeze applications (248319). Antifreeze nozzles are made from brass (gold) instead of steel (silver).
Includes: Ref. No. Part No. Description Qty.

201 246003 NOZZLE, quick close 1
Includes:

Ref. No. Part No. Description Qty.
301 246003 NOZZLE, quick close 1
This same kit is available for antifreeze applications (248320). Antifreeze nozzles are made from brass (gold) instead of steel (silver).

Maximum Fluid Working Pressure 1500 psi (10.3 MPa, 103 bar)
Operating pressure range (* ◆) 100 to 1500 psi (0.7 to 10.3 MPa) (7 bar to 103 bar)
Maximum Dynamic Working Pressure (while dispensing) (★)
600 psi (4.1 MPa, 41.4 bar)
Flow Range 0.26 to 5 gpm (1 to 18.9 lpm)
Weight (with battery and rigid nozzle extension 4.5 lb (2.0 kg)
Units of measurement user selectable, pints, quarts, gallons or liters
Maximum recorded dispense volume 999.00 units
Maximum preset volume 900.0
Inlet size 1/2” npt(f)
Outlet size 3/8” npt(f)
Operating temperature range 32° F to 120° F (0° C to 49° C)
Storage temperature range -30° F to 120° F (-34° C to 49° C)
Battery rechargeable nickel-metal hydride 9.6 VDC
Battery Warranty 6 months
Battery storage temperature range 50° F to 86° F (10° C to 30° C)
Wetted parts zinc, stainless steel, carbon steel, polyurethane, nitrile rubber
Fluid compatibility lubricating oils, antifreeze mixtures
Accuracy (†) +/- 0.5 percent
Repeatability (‡) +/- 0.15 percent
RF Communication 902-928 MHz frequency hopping, spread-spectrum - N. A. 915-928 MHz frequency hopping, spread-spectrum - Australia
Unobstructed RF Communication Range (based on building construction and RF environment)
300-500 ft. (91.0-152.0 m)
Obstructed RF Communication Range (based on building construction and RF environment)
250-300 ft. (76.2-91.0 m)
Approvals (for RF device contained in meter 246008) FCC, Industry Canada (IC)
Conformity (for RF device contained in meter 249881) ACMA (Australia)
* Minimum pressure loss at 1.5 gpm (5.7 lpm) with 30-weight oil at 70° F (21° C) is 70 psi.
† At 2.5 gpm (9.5 lpm), at 70° F (21° C) with 10-weight oil, and 1 gallon dispensed. May require calibration.
‡ At 2.5 gpm (9.5 lpm), at 70° F (21° C) with 10-weight oil, and 1 gallon dispensed.
◆Specification based on 30W oil. Lighter viscosity fluid (i.e., anti-freeze) will require a slightly higher inlet fluid
pressure to open the Matrix valve.
★Using 30W oil at 70°F (21°C). Maximum pressure will be slightly lower with higher viscosity fluids (i.e., gear oil).
A lower ratio pump may be required to reduce system pressure and maintain sufficient flow.
Technical Specifications



A 17.5 in. (444.5 mm) overall length without nozzle dispense kit
B 4.75 in. (120.6 mm) overall width
C 5.25 in. (133.3 mm) overall height

Dimensions · ti64306

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twenty-four months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective with the exception of the Matrix Meter Battery, part number 117310 which has a warranty period of six months from the date of sale to the original purchaser. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco's written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco's sole obligation and buyer's sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents
Original instructions. This manual contains English. MM 309497
Copyright 2003, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com Revised July 2012
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Battery display bars do not appear. | Battery has low charge. | Recharge battery. | p.16 |
| Meter display does not activate. | Battery is dead. | Attempt to recharge a dead battery using procedures outlined in the Battery Charger Instruction Manual (309502). If procedure does not restore a normal charge, replace the battery. | p.16 |
| Meter display does not activate. | Battery inserted too soon. | Wait 30 seconds and reinstall fully charged battery. | p.16 |
| Meter display does not activate. | Cable connections are loose or dis- connected. | Ensure cables are properly connected. See page 22. | p.16 |
| Meter display does not activate. | Electronic display is damaged. | Replace with Bezel Repair Kit (246438). See page 33. | p.16 |
| Slow or no fluid flow from meter. | CleanLine filter system is clogged. | Clean or replace the CleanLine filter. Refer to the Clean- Line Filter System Instruction Manual (310652). | p.16 |
| Slow or no fluid flow from meter. | Meter is not in dispense mode. | See dispense options, page 14. | p.16 |
| Slow or no fluid flow from meter. | Matrix meter filter is clogged. | Clean or replace the Matrix meter filter element. See Cleaning or Replacing the FIlter page 21. | p.16 |
| Slow or no fluid flow from meter. | Pump pressure is low. | Turn up air pressure to the pump. SeeTechnical Speci- fications page 35. | p.16 |
| Slow or no fluid flow from meter. | Pump or reel fluid shut-off valve is not fully open. | Fully open pump or reel fluid shut-off valve. | p.16 |
| Slow or no fluid flow from meter. | Meter hydraulic valve is not function- ing. | If meter bars are lit indicating flow, the nozzle tip is fully open, and the fluid flow has been verified to the meter valve inlet, then the meter hydraulic valve has failed and the meter should be replaced. | p.16 |
| Slow or no fluid flow from meter. | Electronic board connections may be loose or disconnected. | Verify that all connectors are connected or re-seated to the board connections. See page 22. | p.16 |
| Slow or no fluid flow from meter. | Trigger membrane switch is dam- aged - flow bars DO NOT show on the meter display when the trigger IS actuated. | Replace the trigger membrane using the Trigger Repair Kit (246439 N. A., 249883 Australia). See page 33. | p.16 |
| Slow or no fluid flow from meter. | Meter valve is blocked with debris - flow bars DO show on the meter dis- play when trigger IS actuated. | Flush the valve with mineral spirits at high pressure and flow. Warning: do not exceed the maximum working pressure of the meter (1500psi - 103 bar). | p.16 |
| Slow or no fluid flow from meter. | Quick close nozzle is closed. | Open nozzle, see FIG. 21 on page 15. | p.16 |
| Slow or no fluid flow from meter. | A hydraulic quick disconnect was used to connect the meter to the dis- pense hose, allowing debris to clog meter. | Quick disconnects should not be used with Matrix prod- uct, doing so voids the warranty. | p.16 |
| Meter does not stop dispensing. | Meter valve is blocked with debris - flow bars DO NOT show on the meter display when the trigger IS NOT actu- ated. | Flush the valve with mineral spirits at high pressure and flow. Warning: Do not exceed the maximum working pressure of the meter (1500 psi - 103 bar). If flushing does not resolve the problem, the meter should be replaced. | p.17 |
| Meter does not stop dispensing. | Trigger or trigger membrane switch is damaged - flow bars DO show on the meter display when the trigger IS NOT actuated. | Replace the trigger and trigger membrane using the Trigger Repair Kit (246439 N. A., 249883 Australia). See page 33. Do not use clamps or wire ties to hold trigger during dispense, doing so voids the warranty. | p.17 |
| Meter does not stop dispensing. | Dynamic System Pressure (while dis- pensing) exceeds the recommended 600 psi (4.1 MPa, 41.4 bar). | Reduce system pressure. A lower ratio pump may be required to reduce pressure and maintain sufficient flow. | p.17 |
| Meter does not stop dispensing. | A hydraulic quick disconnect was used to connect the meter to the dis- pense hose, allowing debris to block meter. | Do not use quick disconnects with Matrix product. Use of quick disconnects voids the warranty. | p.17 |
| Displayed dis- pensed amount is not accurate. | Meter is not programmed for the cor- rect fluid type. | Verify meter programming. | p.17 |
| Displayed dis- pensed amount is not accurate. | Meter gears are worn. | Meter requires calibration due to wear. See page 19. | p.17 |
| Meter will not take work orders. | Battery has low charge or is dead. | Recharge battery. | p.17 |
| Meter will not take work orders. | Battery inserted too soon. | Wait 30 seconds and reinstall fully charged battery. | p.17 |
| Meter will not take work orders. | Meter may not be programmed. | Reprogram meter. | p.17 |
| Meter will not take work orders. | Battery may have been pulled during programming. | Reprogram meter. | p.17 |
| Meter will not take work orders. | Two meters may be programmed as the same meter. | Ensure each meter is programmed individually. | p.17 |
| Meter will not take work orders. | Meter work order list is full. | Normal operation. Meter will hold up to 5 work orders. | p.17 |
| Meter has intermit- tent or no RF com- munication. | Meter is outside RF communication range of transceiver. | Reposition transceiver or add a transceiver. | p.17 |
| Meter has intermit- tent or no RF com- munication. | Two meters may be programmed as the same meter. | Ensure each meter is programmed individually. | p.17 |
| Meter has intermit- tent or no RF com- munication. | PC or transceiver is off. | Turn PC on, open Matrix application, and check power on transceiver. | p.17 |
| Meter will not pro- gram. | Incorrect COM port selected for transceiver connection. | Change to correct COM port at the PC in Matrix trans- ceiver configuration screen. | p.17 |
| Meter will not pro- gram. | Transceiver is not powered up. | Power up transceiver, wait 30 seconds or until red lights go blank and green light remains on alone. | p.17 |
| Meter will not pro- gram. | Transceiver dip switches are not set for the communication cable being used. | See transceiver manual 309498 to set dip switches. | p.17 |
| Meter will not pro- gram. | Matrix program is not in programming mode. | Place PC in programming mode. See Programming the Meter, page 4. | p.17 |
| Meter will not pro- gram. | The five-minute programming ses- sion has expired. | Place PC in programming mode. See Programming the Meter, page 4. | p.17 |
| Meter will not pro- gram. | Network and transceiver settings on the meter are not correctly set. | Make appropriate settings. See Programming the Meter, page 4. | p.17 |
| Meter will not pro- gram. | Meter is outside RF communication range of transceiver. | Reposition transceiver or add a transceiver. | p.17 |
| Meter has been in service for an extended period of time and begins to work erratically such as loss of Work Orders or Security settings. | E-Prom on meter board has reached the end of its life. | Attempt to reprogram the meter. If you see a pop-up screen on the PC that says, “Memory Failure” and/or the meter screen defaults to the ACTIVATE/ACTIVATE screen, the E-Prom on the meter board must be changed. Install the Electronics Repair Kit (246675). The Electronics Repair Kit includes a new meter board with E-Prom. The meter then can be reprogrammed to the features desired. | p.18 |
| Meter leaks. | Extension may be loose from meter fluid housing. | Tighten seal nut using two wrenches. | p.18 |
| Meter leaks. | Swivel connection at hose may be leaking. | Clean, seal, and tighten joint. | p.18 |
| Meter cuts on and off during preset dispense. | The trigger is being held during pre- set dispense. | Release the trigger during preset dispense. | p.18 |
| Meter cuts on and off during preset dispense. | Trigger or trigger membrane switch is damaged - flow bars DO show on the meter display when the trigger IS NOT actuated. | Replace the trigger and trigger membrane using the Trigger Repair Kit (246439 N. A., 249883 Australia). See page 33. Do not use clamps or wire ties to hold trigger during dispense, doing so voids the warranty. | p.18 |
| Meter displays “active trig” | Trigger or trigger membrane switch is damaged - flow bars DO show on the meter display when the trigger IS NOT actuated. | Replace the trigger and trigger membrane using the Trigger Repair Kit (246439). See page 33. Do not use clamps or wire ties to hold trigger during dispense, doing so voids the warranty. | p.18 |
| Meter displays “active trig” | Trigger is being held before activating meter for dispense. | Release trigger to activate meter. | p.18 |