Part No. 249269, Series A, North America (N.A.) Part No. 249880, Series A, Australia
Used to evaluate the Matrix RF signal quality in a new or existing Matrix facility.

✓ Australian Vendor Code: N3845
FCC ID: JHIGNET IC: 4840AGNET
Industry Canada Statement The term “IC” before the certification/reg- istration number only signifies that the Industry Canada technical specifications were met.
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 Copyright 2005, Graco Inc. is registered to I.S. EN ISO 9001
LISTED

Determining Transceiver Dipswitch Settings 8
Manual Conventions 2
Dipswitch Setting using RS422 Connection 9 Parts for 249269 and 249880 Matrix RF Signal Tester
Warnings 3 Overview 4 Removing and Replacing the Battery 4 Display Functions 5
10 Technical Specifications 11 Dimensions 11 Graco Standard Warranty 12 Graco Phone Numbers 12
Asleep / Awake Mode 5 Battery Life Indicator 5 Operation 5
Preliminary Settings 5 Select Network and Transceiver ID 6 Performing the RF Signal Test 6 Optional Display Information 7
WARNING
A note indicates additional helpful information.
Manual Conventions

The following general warnings are related to the safe setup, use, grounding, maintenance and repair of this equip- ment. Additional more specific warnings may be found throughout the text of this manual where applicable.
FIRE AND EXPLOSION HAZARD When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be aware that flammable fumes can ignite or explode. To help prevent fire and explosion:
BATTERY SAFETY The battery may leak, explode, cause burns, or cause an explosion if mishandled:

The Matrix RF Signal Tester is used to evaluate the Matrix RF signal quality for locating the Transceiver(s) in a new or existing Matrix facility.
The RF Signal Tester requires a Matrix Transceiver to function properly. The Transceiver must be posi- tioned in the building as close as possible to the position of intended installation. The Transceiver must be pow- ered up, but does not need to be connected to a PC.
The quality of Matrix RF signals can be affected by building characteristics such as building size and type of construction. Other RF devices located in the building or close by can also interfere with Matrix RF signals. The RF Signal Tester will assist you in positioning the Matrix Transceiver(s) in the best possible location.
If the facility already has a functioning Matrix system, the RF Signal Tester can utilize the existing Transceiver without interrupting or interfering with the Matrix system. A second “test” Transceiver can still be used, if desired, as long as its dip switch settings are not already in use by another Transceiver in the facility.
The RF Signal Tester is battery powered and contains RF hardware identical to that used in Matrix Meters and Tank Level Monitors (TLMs).

F
E
Read warnings on page 3.
Overview

Asleep / Awake Mode
Asleep is a battery-saving mode in which the display goes blank after a five-minute period of no button or trig- ger switch activity. An RF test lasting longer than five minutes will stop and the LCD display backlight will go out as the Signal Tester enters the sleep mode.
The display comes Awake from sleep mode when any display button is pressed. RF testing will not automati- cally restart. To resume testing press the trigger switch.

On the right side of the display is a series of four bars located under the word BATT. See FIG. 2. The presence of all four bars indicates a fully charged battery. The bars decline in number as the Signal Tester is used and the battery discharges. All Matrix signal tester batteries should be re-charged using a Graco Matrix battery char- ger at the end of the working day to assure good perfor- mance the next day.
Preliminary Settings

Display Functions

If the PROGRAM screen is selected during an RF signal test, the test will stop. The testing then must be manually restarted.
If necessary to determine the Transceiver dipswitch set- tings see Determining Transceiver Dipswitch Set- tings on page 8 for a guide. It does not matter if an RS232 connection or an RS422 connection is used or will be used in the installation. To perform the test all that’s needed is a powered on Transceiver and the correct network ID and Transceiver ID entered into the RF signal tester.

Press the SELECT button (A) to toggle between the Network and Transceiver ID. Use the center up/down buttons (C) to change letter designations. See FIG. 4.
Once the RF test begins, the Signal Tester transmits ten test messages to the Transceiver and “listens” for the Transceiver to send a signal back to the Signal Tester acknowledging that the message was received. This series of ten test messages is called a test interval and takes approximately ten seconds. However, the ten sec- ond interval can vary depending on the RF environment and signal quality.


The Network ID and Transceiver ID screen also displays the software revision level for the tester. See FIG. 4.
Operation

GOOD SIGNAL: If over several test intervals the result is consistently a GOOD SIGNAL, the location is within the range of the Transceiver for reliable communication.
Each test interval sends 10 messages to the Trans- ceiver. Each of these 10 messages is resent up to 10 times or until the RF tester receives a response from the Transceiver. If no response is received after resending the individual message 10 times the RF tester moves on to the next text message and resends it up to 10 times or until a response is received from the Transceiver.
BAD SIGNAL: If the results are consistently a BAD SIG- NAL, (despite an occasional GOOD SIGNAL reading), the location is not within the range of reliable Trans- ceiver communication.
Once all 10 test interval messages have been sent and RF testing is complete, the number of retries for each of the 10 messages is totaled (anywhere from 1-100) and then divided by 10 to get the AVG. RETRIES number. This number is displayed on the RF tester screen.
Pressing the trigger anytime during the test stops the testing at the last message sent. Pressing the RF tester trigger again resets the tester to zero and restarts the testing.
For example, FIG. 7 illustrates an RF interval test where a total of 50 resend messages were bad out of a possi- ble 100 (10 test interval messages x 10 retries = 100) 100 ÷ 50 = 5.
Perform RF signal testing at all Meter and TLM locations to determine an appropriate mounting location for the Transceiver(s).
A test interval that has an AVG. RETRIES of 4 or more is considered a BAD SIGNAL. An average of less than 4 is considered a GOOD SIGNAL.
If a Transceiver needs to be repositioned or another Transceiver needs to be added to the sys- tem, be sure to repeat RF signal testing at all Meter and TLM locations in the facility to assure reliable RF communication from the new Transceiver loca- tion(s).

The number of retries for each test interval is used to calculate if the return signal is a GOOD SIGNAL or a BAD SIGNAL. This optional/additional information can be displayed if desired for signal troubleshooting/analy- sis. It is not necessary to display this information for general RF Signal testing.
Optional information is displayed by pressing the up center button (C) during the RF signal testing process. Pressing the down center button (C) during the RF sig- nal testing process hides this information. See FIG. 7.
Operation

Determining Transceiver Dipswitch Settings
Each Transceiver is equipped with two, 4 - position dip- switches labeled S1 and S2 representing the network ID (S1) setting and the Transceiver ID (S2) setting. See FIG. 8. There is a possibility of (8) Network ID's and (8) Transceiver ID's. The eight positions for each Network ID and Transceiver ID are identified as A, B, C, D, E, F, G, and H. See FIG. 9 and FIG. 10.
Existing Matrix Facility - If the Transceiver is already installed, two large letters should be visible on the out- side of the box. The first letter represents the Network ID and the second letter represents the Transceiver ID.
If no letters are present on the installed Transceiver, it may be necessary to look inside the Transceiver box to determine the dipswitch settings. First determine if an RS232 or an RS422 connection is used and then refer to FIG. 9 and FIG. 10 to determine the Network ID and Transceiver ID.
Testing can be completed while the Matrix system is in use. The test messages sent by the RF Signal Tester will be ignored by the PC that is connected to the system.
New Matrix Facility - the factory default setting for all Transceivers is (AA). The first A refers to the Network ID and the second A refers to the Transceiver ID. It does not matter in a new installation if an RS232 or an RS 422 connection will be used at the time of installation.

Transceiver ID (S2) · Network ID (S1)

Determining Transceiver Dipswitch Settings
Dipswitch Settings using RA232 Connection.
A - default
on B
on C
on D
1 2 3 4 S2
1 2 3 4 S2
1 2 3 4 S2
on F
G
on E
on H
1 2 3 4 S2
1 2 3 4 S2
1 2 3 4 S2
1 2 3 4 S2
H S1 Network ID
B
D
E
F
G
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
S1
S1
S1
S1
S1
S1
S1
Dipswitch Setting using RS422 Connection
S2 Transceiver ID
A
on B
on C
on D
1 2 3 4 S2
1 2 3 4 S2
1 2 3 4 S2
1 2 3 4 S2
G
on E
on F
on H
1 2 3 4 S2
1 2 3 4 S2
1 2 3 4 S2
1 2 3 4 S2
S1 Network ID
A
B
D
E
F
G
H
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
S1
S1
S1
S1
S1
S1
S1

Parts for 249269 and 249880 Matrix RF Signal Tester

Battery is rechargeable and requires a Graco Matrix Battery Charger for recharging. See Instruction Manual 309502.
Ref. No. Part No. Description Qty. 1 117310 BATTERY, 9.6V NMH rechargable 1 2 117427 CHARGER, single bay (not shown) (N.A.) 1 120106 CHARGER, single bay (not shown) (Australia) 1
3 117429 CHARGER, four bay (not shown) (N.A.) 1 120107 CHARGER, four bay (not shown) (Australia) 1

Operating temperature range 32° F to 120° F (0° C to 49° C)
Storage temperature range -30° F to 120° F (-34° C to 49° C)
Battery rechargeable nickel-metal hydride 9.6 VDC
Battery storage temperature range 50° F to 86° F (10° C to 30° C)
RF Communication 902-928 MHz frequency hopping, spread-spectrum (N.A.)
915-928 MHz frequency hopping, spread-spectrum (Australia)
Unobstructed RF Communication Range (based on building construction and RF environment)
300-500 ft (91.0-152.0 m)
Obstructed RF Communication Range (based on building construction and RF environment)
250-300 ft (76.2-91.0 m)
Conformity (for 249880, Australia) ACMA (Australia)
Approvals (for 249269 N.A.) FCC, Industry Canada (IC)
A 12.0 in. (304.8 mm) overall length
B 4.75 in. (120.6 mm) overall width
C 5.25 in. (133.3 mm) overall height
A
TI6745
Technical Specifications

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twenty-four months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco's written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco's sole obligation and buyer's sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents
Original instructions. This manual contains English. MM 311002
Copyright 2004, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com Revised July 2012
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.