This page contains a summary of changes or additions that do not appear in the contents of the manual.
Improve pressure control instructions (Graco Ref. 6557). Change 30psi HVLP fluid regulator and gauge to a 60psi gauge and regulator. Obsolete suction tube (Graco Ref. 6557).


CAUTION
Anybody who operates this system should be trained in the safe, efficient operation of all system components. At a minimum, all operators should thoroughly read the safety, setup, and operation sections of this manual.
This equipment is compatible with most water-based materials. See the wetted parts in the Technical Data section and your fluid and solvent manufacturer’s compatibility information.
Do not use acid catalyzed materials; they are incom- patible with the acetal used in this pump.
Use a compressor capable of delivering 40 cfm (1.12 m3) and a minimum of 80 psi (552 kPa, 5.4 bar) for efficient operation.
TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.
Clear obstacles and debris that could cause an unsafe operating environment.
Run a 1/2 in. I.D. air line from your compressed air supply to the pump location. Be sure the air is dry and filtered.
Read TOXIC FLUID HAZARD on page 3.
When the bleed-type master air valve (K) is closed and the pump air regulator is opened, it relieves all air pressure to the system components.
Use fluids and solvents that are compatible with the equipment wetted parts. Refer to the Tech- nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.
Ventilate the spray booth.
To prevent hazardous concentrations of toxic and/or flammable vapors, spray only in a properly ventilated spray booth. Never operate the spray gun unless ventilation fans are operating.
Always use Genuine Graco Parts and Accessories, available from your Graco distributor. See the Product Data Sheet for this package, Form No. 305–898. If you supply your own accessories, be sure they are adequately sized and pressure rated for your system.
Check and follow all of the national, state, and local codes regarding air exhaust velocity requirements.
Reference numbers and letters in parentheses refer to the callouts in the figures and the parts lists on pages 10 and 12.

Assembling the Wall-Mount Unit See Fig. 1
Install the wall bracket (G) 5 ft (1.5 m) above the floor. For proper hole dimensions, use the Wall Mounting Hole Layout on page 15. Be sure the wall is strong enough to support the weight of the pump and hoses, any accessories, the fluid, and stress caused by pump operation.
To reduce the risk of static sparking, the entire system must be grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Ground all of this equipment. Also read FIRE AND EXPLOSION HAZARD on page 2.
Screw the bung plug (R) into the drum bung opening. Adjust the suction tube (L) so the end of the tube is about 1/2 in. (13 mm) off the bottom of the drum, and secure the suction tube using the thumbscrew on the bung plug.
Pump: One end of the ground wire is already connected to the pump grounding strip. Connect the clamp end of the ground wire to a true earth ground.
Air compressor: Follow the manufacturer’s recommendations.
This package is shipped with the hoses connected. Before you disconnect any hoses, make a note of the proper connections.
Object being sprayed: Follow the local code.
Fluid supply container: Follow the local code.
All solvent pails used when flushing: Follow the local code. Use only metal pails, which are conductive. Do not place the pail on a non-conductive surface, such as paper or cardboard, which interrupts the grounding continuity.
The pump was tested in water. If the test solution could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible solvent. See Flushing the System on page 8.
Systems with PRO 3500sc and PRO 4500sc electrostatic gun: Make sure you read all of the grounding instructions and warnings in your gun instruction manual.

See the gun instruction manual for gun operation, care, flushing, cleaning, and technical data. Read the entire gun manual before operating the sprayer.
Pressure Relief Procedure See Fig. 1
The system remains pressurized until pressure is manually relieved. To reduce the risk of serious injury from pressurized fluid, accidental spray from the gun, or splashing of any fluid, follow this proce- dure whenever you
Systems with Fluid Pressure Regulator See Fig. 1
With the fluid pressure regulator (G), you can control fluid pressure from the pump to the gun. For an accurate setting, adjust the fluid regulator only when the gun is triggered and fluid is flowing through the regulator. Be sure the jam nut under the T–handle (G) does not interfere with your adjustments. Tighten the jam nut to lock in the setting, if desired.
Stop spraying Are instructed to relieve pressure Check or service any system equipment Install, clean, or change spray nozzles
Systems with Surge Tank See Parts Drawing on page 13
Adjusting Pump and Gun Air Regulators See Fig. 1
In systems with a surge tank (30), the fluid pressure is the same as the air pressure applied to the pump (pump has 1:1 ratio of fluid to air). Adjust the fluid pressure as required with the pump air regulator (E).
The surge tank filter screen may require periodic cleaning. First, relieve the pressure. Unscrew the surge tank cover from its base, and remove the filter screen. Clean the screen with a compatible solvent, and reinstall it in the surge tank. Make sure you reinstall the cover with a firm hand torque to ensure a good seal.
Always adjust the pump air regulator (E) and gun air regulator (F) slowly to prevent surging during startup. Turn the knobs clockwise to increase pressure, and counterclockwise to decrease air pressure.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 6.

Priming the System See Fig. 1
The gun emits air until the fluid arrives. When fluid flows freely, release the gun trigger.
Delta Spray regulated Air Spray package or regulated HVLP package shown
KEY A Husky 307 pump B Gun C Gun fluid hose D Gun air hose E Pump air regulator F Gun air regulator G Fluid pressure regulator H Pump ground wire K Bleed-type master air valve L Suction tube M Front shield assembly N Back shield P Lifting handle Q Wall bracket R Bung plug


Shut down the system at the end of the work shift and before checking, adjusting, cleaning, or repairing the system. Always relieve the pressure.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 6.
Flush the system at the following times:
Before the first-time use
When changing colors
For flushing after spraying fluid: trigger the gun and flush with solvent until the system is thoroughly cleaned.
Before fluid can dry or settle out in a dormant system.
Before storing the system
Flush the system as follows (See Fig. 1):
The system is now ready to be stored or primed with another fluid. See Priming the System on page 7.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 6.

See the separate component instruction manuals for individual component maintenance procedures.
Access to some system components requires that you remove the shields. The following steps are for shield removal. Shield replacement is the reverse of these steps, so make sure you take notes on the proper hose connections. Depending on your system, see the Parts Drawings on pages 11 and 13 for number call-outs.
Front Shield Assembly (1)
Clear, stick-on/peel-off lense covers are available for the gauges. These covers protect the gauge lenses from spray. When they get too dirty to read the gauges, they can be peeled off, discarded, and replaced. Order as follows:
240–441 for 2.5-inch gauges; package of 25 sheets, 12 lense covers to a sheet
240–442 for 2-inch gauges; package of 25 sheets, 12 lense covers to a sheet
Front Shield Assembly Orderable Parts
Ref. No. Part No. Description Qty.
1a 192–995 SHIELD, front 1 1b 111–804 REGULATOR, air See instruction manual 308–167 2 1c 160–430 GAUGE, pressure 2 1d 114–362 VALVE, ball 1 1e 159–840 ADAPTER 2 1f 188–077 NIPPLE 1 1g 114–369 FITTING, tube 1 1h 114–370 FITTING, tube 1

Wall-Mount Packages with Fluid Pressure Regulators Model No. 240–349, Delta Spray air spray package Model No. 240–350, Delta Spray HVLP package Model No. 240–351, no hoses (31) or gun (30) Model No. 240–352, PRO 3500sc electrostatic package Model No. 240–353, PRO 4500sc electrostatic package
Ref. No. Part No. Description Qty.
Ref. No. Part No. Description Qty.
1 240–210 SHIELD ASSY, front Contains 1a to 1h, shown in Fig. 2 on page 9 1 2 110–789 WASHER, flat 2 3 100–014 SCREW 2 5 104–123 WASHER, spring lock 4 6 102–025 NUT, hex 4 7 192–994 HANDLE, shield 1 8 D31–331 PUMP, Husky 307 See instruction manual 308–553 1 9 054–139 TUBE, flexible 75 in. 10 111–864 CONNECTOR, male 1 11 188–181 PLUG, bung, airtight 1 12 111–276 SCREW, thumb 1 13 111–863 CONNECTION, union 1 15 054–175 HOSE; Nylon 10 in. 16 054–188 TUBE, PTFE 9 in. 17 188–285 BRACKET, wall 1 19 112–899 WASHER, lock 1 20 112–903 NUT, hex 1 21 114–370 FITTING, tube, quick-connect 1 24 104–119 SCREW, cap, hex head 4 25 192–996 SHIELD, back 1 26 104–029 LUG, grounding 1 27 054–139 TUBE; Nylon 11.5 in. 28 189–436 NIPPLE 1 29 189–220 LABEL, warning 1
30 239–542 GUN, Delta Spray, air spray Model 240–349 See instruction manual 308–742 1 239–561 GUN, Delta Spray, HVLP Model 240–350 See instruction manual 308–741 1 222–300 GUN, PRO 3500sc, electrostatic Model 240–352 See instruction manual 307–912 1 224–200 GUN, PRO 4500sc, electrostatic Model 240–353 See instruction manual 308–131 1 31 240–421 HOSE ASSY, air spray/HVLP; 25 ft (7.6 m) Delta packages 1 240–425 HOSE ASSY, PRO gun; 25 ft (7.6 m) PRO packages 1 32 100–333 SCREW, cap, hex head 2 33 114–369 FITTING, tube, quick-connect 1 34 193–251 LABEL, product Delta packages 1 193–252 LABEL, product PRO packages 1 37 238–909 GROUND WIRE & CLAMP ASSY 1 38 188–171 TUBE, suction 1 39 113–521 ELBOW, street 1 40 114–456 ELBOW, street 1 50 236–449 REGULATOR, fluid pressure; 0–30 psi (0–207 kPa, 0–2 bar) Model 240–350 See instruction manual 308–325 1 236–450 REGULATOR, fluid pressure; 0–100 psi (0–0.6 MPa, 0–7 bar) All Models except 240–350 See instruction manual 308–325 1
Extra Warning labels are available for free.

Wall-Mount Packages with Fluid Pressure Regulators Model No. 240–349, Delta Spray air spray package Model No. 240–350, Delta Spray HVLP package Model No. 240–351, no hoses (31) or gun (30) Model No. 240–352, PRO 3500sc electrostatic package Model No. 240–353, PRO 4500sc electrostatic package


·

Wall-Mount Packages with Surge Tanks Model No. 240–361, Delta Spray air spray package Model No. 240–362, Delta Spray HVLP package Model No. 240–363, no hoses (31) or gun (30)
Ref. No. Part No. Description Qty.
Ref. No. Part No. Description Qty.
1 240–210 SHIELD ASSY, front Contains 1a to 1h, shown in Fig. 2 on page 9 1 3 106–285 BOLT, “U” 2 5 104–123 WASHER, spring lock 4 6 102–025 NUT, hex 4 7 188–089 NIPPLE 1 8 D31–331 PUMP, Husky 307 See instruction manual 308–553 1 9 054–139 TUBE, flexible 75 in. 10 111–864 CONNECTOR, male 1 11 188–181 PLUG, bung, airtight 1 12 111–276 SCREW, thumb 1 13 111–863 CONNECTION, union 1 15 054–175 HOSE; Nylon 10 in. 16 054–188 TUBE, PTFE 9 in. 17 188–285 BRACKET, wall 1 19 112–899 WASHER, lock 1 20 112–903 NUT, hex 1 21 114–370 FITTING, tube, quick-connect 1 24 104–119 SCREW, cap, hex head 4
25 192–996 SHIELD, back 1 26 104–029 LUG, grounding 1 27 054–139 TUBE; Nylon 11.5 in. 29 189–220 LABEL, warning 1 30 239–542 GUN, Delta Spray, air spray Model 240–361 See instruction manual 308–742 1 239–561 GUN, Delta Spray, HVLP Model 240–362 See instruction manual 308–741 1 31 240–421 HOSE ASSY, air spray/HVLP; 25 ft (7.6 m) 1 32 100–333 SCREW, cap, hex head 2 33 114–369 FITTING, tube, quick-connect 1 34 193–253 LABEL, product 1 37 238–909 GROUND WIRE & CLAMP ASSY 1 38 188–171 TUBE, suction 1 40 114–456 ELBOW, street 2 50 111–911 STRAINER, line 1
* These parts cannot be ordered separately.
Extra Warning labels are available for free.

Wall-Mount Packages with Surge Tanks Model No. 240–361, Delta Spray air spray package Model No. 240–362, Delta Spray HVLP package Model No. 240–363, no hoses (31) or gun (30)



Ref. No. Part No. Description Qty.
To avoid sharp bends in the tube, you may have to cut it to a shorter length. Apply Graco Thread Sealer, or Loctite 567, or equiv- alent to male threads.
101 114–361 FILTER, fluid 1 102 113–322 CONNECTOR, male 1 103 054–188 TUBE; PTFE;3/8” O.D. 8 in. 104 113–534 ELBOW, male x female 2 105 111–917 NIPPLE; Nylon 1
For initial installation, make sure the dome is firmly
hand tightened onto the filter body. Do not use a tool. During subsequent service, hand tighten more firmly to prevent drips.
The Fluid Filter Kit, listed above, can be installed to filter fluid drawn by the suction tube after it comes out of the pump. Install the Fluid Filter Kit as follows (see Fig. 3):


Maximum fluid working pressure 100 psi (0.7 MPa, 7 bar)
Maximum incoming air pressure 100 psi (0.7 MPa, 7 bar)
Maximum operating temperature 120 F (49 C)
Fluid pressure regulator See separate fluid pressure regulator instruction manual.
Air pressure regulators See separate air pressure regulator instruction manual.
packages with fluid pressure regulator Approx. 29 lb (13 kg)
Sound power level* at 70 psi 0.48 MPa, 4.8 bar) and 115 cpm
Sound pressure level at 70 psi 0.48 MPa, 4.8 bar) and 115 cpm
* Sound power level was measured per ISO Standard 3744.
is a registered trademark
Wall Mounting Hole
Layout


Four 0.438 in. (11 mm) dia. holes (to mount bracket to wall)

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distributor closest to you:
1–800–367–4023 Toll Free
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 http://www.graco.com 1998 Graco Inc. 308845 Rev. C January 2000 PRINTED IN U.S.A.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.