Instruction Manual – Parts List Changes

This page contains a summary of changes or additions that do not appear in the contents of the manual.

Improve pressure control instructions (Graco Ref. 6557). Change 30psi HVLP fluid regulator and gauge to a 60psi gauge and regulator. Obsolete suction tube (Graco Ref. 6557).

1A 308845

Page 3 of the Graco Hydraulic Fluid Motor (240-351) user manual — 1B 308845
Page 3 · click to enlarge
Page 3

Notes

1B 308845

Page 6 of the Graco Hydraulic Fluid Motor (240-351) user manual — General Information
Page 6 · click to enlarge
Page 6

Setup

Preparing the Operator

CAUTION

Anybody who operates this system should be trained in the safe, efficient operation of all system components. At a minimum, all operators should thoroughly read the safety, setup, and operation sections of this manual.

This equipment is compatible with most water-based materials. See the wetted parts in the Technical Data section and your fluid and solvent manufacturer’s compatibility information.

Do not use acid catalyzed materials; they are incom- patible with the acetal used in this pump.

Preparing the Site

Use a compressor capable of delivering 40 cfm (1.12 m3) and a minimum of 80 psi (552 kPa, 5.4 bar) for efficient operation.

TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

Clear obstacles and debris that could cause an unsafe operating environment.

Run a 1/2 in. I.D. air line from your compressed air supply to the pump location. Be sure the air is dry and filtered.

Read TOXIC FLUID HAZARD on page 3.

When the bleed-type master air valve (K) is closed and the pump air regulator is opened, it relieves all air pressure to the system components.

Use fluids and solvents that are compatible with the equipment wetted parts. Refer to the Tech- nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

Ventilate the spray booth.

General Information

To prevent hazardous concentrations of toxic and/or flammable vapors, spray only in a properly ventilated spray booth. Never operate the spray gun unless ventilation fans are operating.

Always use Genuine Graco Parts and Accessories, available from your Graco distributor. See the Product Data Sheet for this package, Form No. 305–898. If you supply your own accessories, be sure they are adequately sized and pressure rated for your system.

Check and follow all of the national, state, and local codes regarding air exhaust velocity requirements.

Reference numbers and letters in parentheses refer to the callouts in the figures and the parts lists on pages 10 and 12.

Page 7 of the Graco Hydraulic Fluid Motor (240-351) user manual — Flush Pump Before First Use
Page 7 · click to enlarge
Page 7

Setup

Assembling the Wall-Mount Unit See Fig. 1

Grounding

Install the wall bracket (G) 5 ft (1.5 m) above the floor. For proper hole dimensions, use the Wall Mounting Hole Layout on page 15. Be sure the wall is strong enough to support the weight of the pump and hoses, any accessories, the fluid, and stress caused by pump operation.

To reduce the risk of static sparking, the entire system must be grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Ground all of this equipment. Also read FIRE AND EXPLOSION HAZARD on page 2.

Screw the bung plug (R) into the drum bung opening. Adjust the suction tube (L) so the end of the tube is about 1/2 in. (13 mm) off the bottom of the drum, and secure the suction tube using the thumbscrew on the bung plug.

Pump: One end of the ground wire is already connected to the pump grounding strip. Connect the clamp end of the ground wire to a true earth ground.

Hose Connections

Air compressor: Follow the manufacturer’s recommendations.

This package is shipped with the hoses connected. Before you disconnect any hoses, make a note of the proper connections.

Object being sprayed: Follow the local code.

Fluid supply container: Follow the local code.

Flush Pump Before First Use

All solvent pails used when flushing: Follow the local code. Use only metal pails, which are conductive. Do not place the pail on a non-conductive surface, such as paper or cardboard, which interrupts the grounding continuity.

The pump was tested in water. If the test solution could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible solvent. See Flushing the System on page 8.

Systems with PRO 3500sc and PRO 4500sc electrostatic gun: Make sure you read all of the grounding instructions and warnings in your gun instruction manual.

Page 8 of the Graco Hydraulic Fluid Motor (240-351) user manual — Using the Gun
Page 8 · click to enlarge
Page 8

Operation

Using the Gun

3. Slowly open the gun air regulator (F), and pull the gun trigger just enough to open only the air valve in the gun. With the gun air triggered, set the gun air pressure to 60 psi (413 kPa, 4 bar).

See the gun instruction manual for gun operation, care, flushing, cleaning, and technical data. Read the entire gun manual before operating the sprayer.

Pressure Relief Procedure See Fig. 1

4. If your system has a fluid pressure regulator (G), fully trigger the gun, and fine tune the fluid pressure to obtain the desired atomization.

The system remains pressurized until pressure is manually relieved. To reduce the risk of serious injury from pressurized fluid, accidental spray from the gun, or splashing of any fluid, follow this proce- dure whenever you

Systems with Fluid Pressure Regulator See Fig. 1

With the fluid pressure regulator (G), you can control fluid pressure from the pump to the gun. For an accurate setting, adjust the fluid regulator only when the gun is triggered and fluid is flowing through the regulator. Be sure the jam nut under the T–handle (G) does not interfere with your adjustments. Tighten the jam nut to lock in the setting, if desired.

Stop spraying Are instructed to relieve pressure Check or service any system equipment Install, clean, or change spray nozzles

1. T urn of f the air supply to the pump.
1. T o open the fluid regulator , which allows fluid to flow, turn the T -hand clockwise.
2. Be sure the pump air regulator is open by turning the knob (E) clockwise several turns.
3. Open the bleed-type master air valve (K) to relieve pump air pressure.
2. T o close the fluid regulator , which restricts or shuts of f the fluid flow , turn the T-handle counterclockwise.
4. T rigger the gun (B) to relieve fluid pressure in the hoses.

Systems with Surge Tank See Parts Drawing on page 13

Adjusting Pump and Gun Air Regulators See Fig. 1

In systems with a surge tank (30), the fluid pressure is the same as the air pressure applied to the pump (pump has 1:1 ratio of fluid to air). Adjust the fluid pressure as required with the pump air regulator (E).

The surge tank filter screen may require periodic cleaning. First, relieve the pressure. Unscrew the surge tank cover from its base, and remove the filter screen. Clean the screen with a compatible solvent, and reinstall it in the surge tank. Make sure you reinstall the cover with a firm hand torque to ensure a good seal.

Always adjust the pump air regulator (E) and gun air regulator (F) slowly to prevent surging during startup. Turn the knobs clockwise to increase pressure, and counterclockwise to decrease air pressure.

1. Slowly adjust the pump air regulator (E), to set air pressure to approximately 60 psi (413 kPa, 4 bar).

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 6.

2. If your system has a fluid pressure regulator , turn the fluid pressure regulator handle (G) to adjust the fluid pressure to 40 to 60 psi ( 276 to 413 kPa, 2.8 to 4 bar).

Page 9 of the Graco Hydraulic Fluid Motor (240-351) user manual — Operation
Page 9 · click to enlarge
Page 9

Operation

Priming the System See Fig. 1

1. Close the gun air regulator (F).
5. Slowly open the gun air regulator (F), and pull the gun trigger just enough to open only the air valve in the gun. With the gun air triggered, set the gun air pressure to 60 psi (413 kPa, 4 bar).
2. If your system has a fluid pressure regulator (G), close it.
6. Hold the gun against and aimed into a grounded metal waste pail, and fully trigger the gun. If your system has a fluid pressure regulator (G), slowly open it.
3. Open the bleed-type master air valve (K).
4. Slowly set the pump air regulator (E) pressure to 20 to 30 psi (140 to 210 kPa, 1.4 to 2.1 bar). The pump cycles quickly , then it slows down when it is primed. Set the pump air pressure to 40 psi (280 kPa, 2.8 bar).

The gun emits air until the fluid arrives. When fluid flows freely, release the gun trigger.

Delta Spray regulated Air Spray package or regulated HVLP package shown

KEY A Husky 307 pump B Gun C Gun fluid hose D Gun air hose E Pump air regulator F Gun air regulator G Fluid pressure regulator H Pump ground wire K Bleed-type master air valve L Suction tube M Front shield assembly N Back shield P Lifting handle Q Wall bracket R Bung plug

Graco Hydraulic Fluid Motor (240-351) — Operation diagram (page 9)
Fig. 1 · Operation

Page 10 of the Graco Hydraulic Fluid Motor (240-351) user manual — Flushing the System
Page 10 · click to enlarge
Page 10

Operation

When to Shut Down the System

4. Make sure the air regulators (E and F) are closed.

Shut down the system at the end of the work shift and before checking, adjusting, cleaning, or repairing the system. Always relieve the pressure.

5. Open the bleed-type master air valve (K).
6. Slowly open the pump air regulator (E) until the pump starts.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 6.

7. Hold the gun against a grounded metal waste pail, and fully trigger the gun. If your system has a fluid pressure regulator (G), slowly open it until the fluid flows smoothly .

Flushing the System

8. When solvent appears, release the gun trigger .

Flush the system at the following times:

9. For a first-time flush : trigger the gun and flush with solvent for 30 seconds.

Before the first-time use

When changing colors

For flushing after spraying fluid: trigger the gun and flush with solvent until the system is thoroughly cleaned.

Before fluid can dry or settle out in a dormant system.

10. Repea t t h e p rocedur e w it h c lea n s olvent , i f n eeded.

Before storing the system

11. Lift the fluid intake tube from the fluid supply , and trigger the gun and run the pump until air comes from the gun.

Flush the system as follows (See Fig. 1):

1. Relieve the pressure.
12. Relieve the pressure .

The system is now ready to be stored or primed with another fluid. See Priming the System on page 7.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 6.

2. Remove the gun air cap before flushing, and clean it separately .
3. Place the suction tube into a grounded metal pail of compatible solvent.

Page 11 of the Graco Hydraulic Fluid Motor (240-351) user manual — Maintenance
Page 11 · click to enlarge
Page 11

Maintenance

See the separate component instruction manuals for individual component maintenance procedures.

Access to some system components requires that you remove the shields. The following steps are for shield removal. Shield replacement is the reverse of these steps, so make sure you take notes on the proper hose connections. Depending on your system, see the Parts Drawings on pages 11 and 13 for number call-outs.

Front Shield Assembly (1)

1. Disconnect the pump air hose from the pump air regulator.
1. Disconnect the gun fluid hose from the fluid pressure regulator nipple (28) or surge tank nipple (7).
2. Disconnect the gun air hose from the gun air regulator.
2. Disconnect the hose (16) that runs from the fluid pressure regulator or surge tank (50) to the elbow (40) on the pump outlet.
3. Loosen, but do not remove, the two front pump foot screws (24).
3. Loosen, but do not remove, the two top shield screws (32).
4. Loosen, but do not remove, the two top shield screws (32).
4. Loosen, but do not remove, the two back pump foot screws (24).
5. If your system has a fluid pressure regulator (50), make sure the T–handle is horizontal.
5. Pull the back shield free of the system. The fluid pressure regulator or surge tank (50) stays mounted to the back shield.
6. Pull the front shield assembly free of the system.

Clear, stick-on/peel-off lense covers are available for the gauges. These covers protect the gauge lenses from spray. When they get too dirty to read the gauges, they can be peeled off, discarded, and replaced. Order as follows:

240–441 for 2.5-inch gauges; package of 25 sheets, 12 lense covers to a sheet

240–442 for 2-inch gauges; package of 25 sheets, 12 lense covers to a sheet

Front Shield Assembly Orderable Parts

Ref. No. Part No. Description Qty.

1a 192–995 SHIELD, front 1 1b 111–804 REGULATOR, air See instruction manual 308–167 2 1c 160–430 GAUGE, pressure 2 1d 114–362 VALVE, ball 1 1e 159–840 ADAPTER 2 1f 188–077 NIPPLE 1 1g 114–369 FITTING, tube 1 1h 114–370 FITTING, tube 1

Show 12 more labels / short text on this page
Back Shield (25) · 1g · 1a · Gauge Lense Covers · 1e 1f · 1d · gun air regulator · 1b · 1h · pump air regulator · ·
Page 12 of the Graco Hydraulic Fluid Motor (240-351) user manual — Parts List
Page 12 · click to enlarge
Page 12

Parts List

Wall-Mount Packages with Fluid Pressure Regulators Model No. 240–349, Delta Spray air spray package Model No. 240–350, Delta Spray HVLP package Model No. 240–351, no hoses (31) or gun (30) Model No. 240–352, PRO 3500sc electrostatic package Model No. 240–353, PRO 4500sc electrostatic package

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

1 240–210 SHIELD ASSY, front Contains 1a to 1h, shown in Fig. 2 on page 9 1 2 110–789 WASHER, flat 2 3 100–014 SCREW 2 5 104–123 WASHER, spring lock 4 6 102–025 NUT, hex 4 7 192–994 HANDLE, shield 1 8 D31–331 PUMP, Husky 307 See instruction manual 308–553 1 9 054–139 TUBE, flexible 75 in. 10 111–864 CONNECTOR, male 1 11 188–181 PLUG, bung, airtight 1 12 111–276 SCREW, thumb 1 13 111–863 CONNECTION, union 1 15 054–175 HOSE; Nylon 10 in. 16 054–188 TUBE, PTFE 9 in. 17 188–285 BRACKET, wall 1 19 112–899 WASHER, lock 1 20 112–903 NUT, hex 1 21 114–370 FITTING, tube, quick-connect 1 24 104–119 SCREW, cap, hex head 4 25 192–996 SHIELD, back 1 26 104–029 LUG, grounding 1 27 054–139 TUBE; Nylon 11.5 in. 28 189–436 NIPPLE 1 29 189–220 LABEL, warning 1

30 239–542 GUN, Delta Spray, air spray Model 240–349 See instruction manual 308–742 1 239–561 GUN, Delta Spray, HVLP Model 240–350 See instruction manual 308–741 1 222–300 GUN, PRO 3500sc, electrostatic Model 240–352 See instruction manual 307–912 1 224–200 GUN, PRO 4500sc, electrostatic Model 240–353 See instruction manual 308–131 1 31 240–421 HOSE ASSY, air spray/HVLP; 25 ft (7.6 m) Delta packages 1 240–425 HOSE ASSY, PRO gun; 25 ft (7.6 m) PRO packages 1 32 100–333 SCREW, cap, hex head 2 33 114–369 FITTING, tube, quick-connect 1 34 193–251 LABEL, product Delta packages 1 193–252 LABEL, product PRO packages 1 37 238–909 GROUND WIRE & CLAMP ASSY 1 38 188–171 TUBE, suction 1 39 113–521 ELBOW, street 1 40 114–456 ELBOW, street 1 50 236–449 REGULATOR, fluid pressure; 0–30 psi (0–207 kPa, 0–2 bar) Model 240–350 See instruction manual 308–325 1 236–450 REGULATOR, fluid pressure; 0–100 psi (0–0.6 MPa, 0–7 bar) All Models except 240–350 See instruction manual 308–325 1

Extra Warning labels are available for free.

Page 13 of the Graco Hydraulic Fluid Motor (240-351) user manual — Parts Drawing
Page 13 · click to enlarge
Page 13

Parts Drawing

Wall-Mount Packages with Fluid Pressure Regulators Model No. 240–349, Delta Spray air spray package Model No. 240–350, Delta Spray HVLP package Model No. 240–351, no hoses (31) or gun (30) Model No. 240–352, PRO 3500sc electrostatic package Model No. 240–353, PRO 4500sc electrostatic package

Graco Hydraulic Fluid Motor (240-351) — Parts Drawing diagram (page 13)
Fig. 2 · Parts Drawing
Graco Hydraulic Fluid Motor (240-351) — Parts Drawing diagram (page 13)
Fig. 3 · Parts Drawing

·

Page 14 of the Graco Hydraulic Fluid Motor (240-351) user manual — Parts List
Page 14 · click to enlarge
Page 14

Parts List

Wall-Mount Packages with Surge Tanks Model No. 240–361, Delta Spray air spray package Model No. 240–362, Delta Spray HVLP package Model No. 240–363, no hoses (31) or gun (30)

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

1 240–210 SHIELD ASSY, front Contains 1a to 1h, shown in Fig. 2 on page 9 1 3 106–285 BOLT, “U” 2 5 104–123 WASHER, spring lock 4 6 102–025 NUT, hex 4 7 188–089 NIPPLE 1 8 D31–331 PUMP, Husky 307 See instruction manual 308–553 1 9 054–139 TUBE, flexible 75 in. 10 111–864 CONNECTOR, male 1 11 188–181 PLUG, bung, airtight 1 12 111–276 SCREW, thumb 1 13 111–863 CONNECTION, union 1 15 054–175 HOSE; Nylon 10 in. 16 054–188 TUBE, PTFE 9 in. 17 188–285 BRACKET, wall 1 19 112–899 WASHER, lock 1 20 112–903 NUT, hex 1 21 114–370 FITTING, tube, quick-connect 1 24 104–119 SCREW, cap, hex head 4

25 192–996 SHIELD, back 1 26 104–029 LUG, grounding 1 27 054–139 TUBE; Nylon 11.5 in. 29 189–220 LABEL, warning 1 30 239–542 GUN, Delta Spray, air spray Model 240–361 See instruction manual 308–742 1 239–561 GUN, Delta Spray, HVLP Model 240–362 See instruction manual 308–741 1 31 240–421 HOSE ASSY, air spray/HVLP; 25 ft (7.6 m) 1 32 100–333 SCREW, cap, hex head 2 33 114–369 FITTING, tube, quick-connect 1 34 193–253 LABEL, product 1 37 238–909 GROUND WIRE & CLAMP ASSY 1 38 188–171 TUBE, suction 1 40 114–456 ELBOW, street 2 50 111–911 STRAINER, line 1

* These parts cannot be ordered separately.

Extra Warning labels are available for free.

Page 15 of the Graco Hydraulic Fluid Motor (240-351) user manual — Parts Drawing
Page 15 · click to enlarge
Page 15

Parts Drawing

Wall-Mount Packages with Surge Tanks Model No. 240–361, Delta Spray air spray package Model No. 240–362, Delta Spray HVLP package Model No. 240–363, no hoses (31) or gun (30)

Graco Hydraulic Fluid Motor (240-351) — Parts Drawing diagram (page 15)
Fig. 4 · Parts Drawing
Graco Hydraulic Fluid Motor (240-351) — Parts Drawing diagram (page 15)
Fig. 5 · Parts Drawing

Page 16 of the Graco Hydraulic Fluid Motor (240-351) user manual — Fluid Filter Kit 240–440
Page 16 · click to enlarge
Page 16

Accessory Fluid Filter Kit

Fluid Filter Kit 240–440

Ref. No. Part No. Description Qty.

To avoid sharp bends in the tube, you may have to cut it to a shorter length. Apply Graco Thread Sealer, or Loctite 567, or equiv- alent to male threads.

101 114–361 FILTER, fluid 1 102 113–322 CONNECTOR, male 1 103 054–188 TUBE; PTFE;3/8” O.D. 8 in. 104 113–534 ELBOW, male x female 2 105 111–917 NIPPLE; Nylon 1

For initial installation, make sure the dome is firmly

hand tightened onto the filter body. Do not use a tool. During subsequent service, hand tighten more firmly to prevent drips.

The Fluid Filter Kit, listed above, can be installed to filter fluid drawn by the suction tube after it comes out of the pump. Install the Fluid Filter Kit as follows (see Fig. 3):

1. Apply thread sealant (specified in Fig. 3) to all male threads in this kit.
2. Remove the elbow (40) from the pump outlet, and remove the tube (16). See the Parts drawing on page 1 1.
3. Thread one the elbows (104) into the pump outlet.
4. Assemble the nipple (105) and the other elbow (104)
5. Thread the nipple (105), with the elbow (104) attached to it, into the elbow (104) that you threaded into the pump outlet.
6. Thread the fluid filter (101) onto the male threads of the elbow (104).
7. Thread the male connector (102) into the fluid filter (101).
8. T urn the fluid filter/male connector assembly towards the elbow (39). This makes connecting the tube (103) in step 9 easier .
9. Cut the PTFE tube (103) to the proper length, and install it to run from the male connector (102) to the elbow (39).
Show 9 more labels / short text on this page
103 · 103 · 102 · 101 · 104 · 105 · 104 · ·
Page 17 of the Graco Hydraulic Fluid Motor (240-351) user manual — Dimensions
Page 17 · click to enlarge
Page 17

Technical Data

Graco Hydraulic Fluid Motor (240-351) — Technical Data diagram (page 17)
Fig. 6 · Technical Data

Maximum fluid working pressure 100 psi (0.7 MPa, 7 bar)

Maximum incoming air pressure 100 psi (0.7 MPa, 7 bar)

Maximum operating temperature 120 F (49 C)

Fluid pressure regulator See separate fluid pressure regulator instruction manual.

Air pressure regulators See separate air pressure regulator instruction manual.

W etted partsfluid hoses for Delta guns nylon, stainless steel
W etted partsfluid hoses for PRO guns nylon, nickel-chrome plate
W etted partsother fluid hoses and tubing nylon, PTFE
W etted partsfluid fittings nylon, acetal, 304/316 stainless steel

packages with fluid pressure regulator Approx. 29 lb (13 kg)

Sound power level* at 70 psi 0.48 MPa, 4.8 bar) and 115 cpm

Sound pressure level at 70 psi 0.48 MPa, 4.8 bar) and 115 cpm

* Sound power level was measured per ISO Standard 3744.

PTFE

is a registered trademark

Dimensions

Wall Mounting Hole

Layout

Graco Hydraulic Fluid Motor (240-351) — Dimensions diagram (page 17)
Fig. 7 · Dimensions
Graco Hydraulic Fluid Motor (240-351) — Dimensions diagram (page 17)
Fig. 8 · Dimensions

Four 0.438 in. (11 mm) dia. holes (to mount bracket to wall)

Page 18 of the Graco Hydraulic Fluid Motor (240-351) user manual — Graco Phone Number
Page 18 · click to enlarge
Page 18

Graco Standard W arranty

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.

Graco Phone Number

TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distributor closest to you:

1–800–367–4023 Toll Free

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Sales OfficesMinneapolis, Detroit Foreign Offices: Belgium, Korea, Hong Kong, Japan

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 http://www.graco.com 1998 Graco Inc. 308845 Rev. C January 2000 PRINTED IN U.S.A.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Graco Hydraulic Fluid Motor (240-351)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco Hydraulic Fluid Motor (240-351)

Be the first to ask — other owners or our team will answer.

Original document

Graco Hydraulic Fluid Motor (240-351) manual PDF

18 pages·727 KB·Pet Fence·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…