Instructions–Parts List

STAINLESS STEEL, WATERBASE-COMPATIBLE, HIGH PRESSURE Fluid Pressure Regulators

308647P

EN

For precise downstream pressure and flow control.

Model 238890, 238892 (spring-operated)

Model 238894 (air-operated)

U.S. Patent No. 4942899

06540A

Page 3 of the Graco 238892 user manual — INSTRUCTIONS
Page 3 · click to enlarge
Page 3

Symbols

Warning Symbol

Caution Symbol

CAUTION

This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.

This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.

INSTRUCTIONS

This equipment is for professional use only.

Read all instruction manuals, tags, and labels before operating the equipment.

Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.

Do not alter or modify this equipment. Use only genuine Graco parts and accessories.

Check equipment daily. Repair or replace worn or damaged parts immediately.

Do not kink or over bend the hose or use the hose to pull equipment.

Do not exceed the maximum working pressure of the lowest rated component in your system. Do not exceed 6000 psi (41 MPa, 414 bar) maximum fluid inlet pressure of the regulator or the maximum working pressure of the lowest-rated component in your system.

Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

Always wear protective eyewear, gloves, clothing, and respirator as recommended by the fluid and solvent manufacturer.

Comply with all applicable local, state, and national fire, electrical, and safety regulations.

3 308647

Page 4 of the Graco 238892 user manual — Symbols
Page 4 · click to enlarge
Page 4
WARNING SKIN INJECTION HAZARD Spray from the gun, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate surgical treatment. Do not point the gun at anyone or at any part of the body. Do not put your hand or fingers over the spray gun tip or extruder gun tip. Do not stop or deflect leaks with your hand, body, glove or rag. Always have the tip guard and the trigger guard on the gun when spraying. Check the gun diffuser operation weekly. Refer to the gun manual. Be sure the gun trigger safety operates before spraying. Lock the gun trigger safety when you stop dispensing. Follow the Pressure Relief Procedure on page 7 if the spray tip clogs and before cleaning, checking, or servicing the equipment. Tighten all fluid connections before operating the equipment. Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose. Fluid hoses must have spring guards on both ends to help protect them from rupture caused by kinks or bends near the couplings. HALOGENATED HYDROCARBON HAZARD Never use 1,1,1–trichloroethane, methylene chloride, other halogenated hydrocarbon solvents, or fluids containing such solvents in these regulators. In the unlikely event that there is a diaphragm failure and the vent hole in the aluminum spring cap is plugged, a serious chemical reaction could occur, with the possibility of explosion, which could cause death, serious injury, and/or substantial property damage. Consult your fluid suppliers to ensure that the fluids used are compatible with aluminum parts. TOXIC FLUID HAZARD Graco does not manufacture or supply the reactive chemical components that may be used in this equipment and is not responsible for injury or property loss, damage, expense or claims (direct or consequential) that arise from the use of such chemical components.

4 308647

Page 5 of the Graco 238892 user manual — Notes
Page 5 · click to enlarge
Page 5

Notes

5 308647

Page 6 of the Graco 238892 user manual — Mounting Bracket
Page 6 · click to enlarge
Page 6

Installation

Multiple Circulating Spray Station

M

E F

K

Key

A Air regulator B Bleed-type master air valve C Pump D Fluid filter and drain valve E Main fluid supply line F Gun fluid supply line G Fluid regulator with fluid pressure gauge (H) H Fluid pressure gauge J Air-assisted airless spray gun K Back pressure valve L Fluid return line M Main circulating line N Fluid supply container P Drain valve

J

J

A B

K

G

G

H

H

P

P

N

D

Single Direct Spray Station

A B

J

G

Do not use PTFE tape on pipe threads. Such use could cause a hazardous condition due to loss of grounding continuity. Also, if pieces of the tape break off, the function of the regulator could be affected.

H

F

06462 P

D

The installations shown in Fig. 1 are only a guide for selecting and installing a circulating or direct system; they are not actual system designs. Contact your Graco distributor for assistance in designing a system to suit your needs.

Apply pipe sealant to the male pipe threads, and connect the fluid supply line (F) to the fluid regulator’s 3/8 npt(f) inlet. Connect the line from the gun (J) to the fluid regulator’s 3/8 npt(f) outlet. Install the gauge or plug into the 1/4 npt(f) gauge port.

Make sure the direction of fluid flow agrees with the IN and OUT markings on the regulator body.

Flush the System

The regulator was tested in lightweight oil. Flush the entire system with a solvent compatible with the fluid being dispensed. Then test the system.

Connections

Install the fluid regulator (G) in the spray gun fluid supply line (F), as shown in the typical installation drawings on this page. Connect only one spray gun or dispensing valve to each fluid regulator.

Mounting Bracket

A Mounting Bracket is available for mounting the regulator. Order Part 222515 for the bracket and mounting hardware.

6 308647

Page 7 of the Graco 238892 user manual — Z
Page 7 · click to enlarge
Page 7

Installation

Grounding the System

Spray gun: Ground through connection to a properly grounded fluid hose and pump.

Fluid supply container: Follow your local code.

FIRE AND EXPLOSION HAZARD Before operating the fluid pressure regulator, ground the system as explained below.

Object being sprayed: Follow your local code.

Solvent pails used when flushing: Follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continuity.

Pump: Use a ground wire and clamp. Loosen the grounding lug locknut (W) and washer (X). Insert one end of a 1.5 mm (12 ga) minimum ground wire (Y) into the slot in lug (Z) and tighten the locknut securely. Connect the other end of the wire to a true earth ground. Order Part 237569 Ground Wire and Clamp.

To maintain grounding continuity when flushing or relieving pressure, hold a metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

Pressure Relief Procedure

W

X Y

SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you

Z

Are instructed to relieve the pressure

Air and fluid hoses: Use only electrically conductive hoses.

Check or service any of the system equipment

Heaters, if used: See the heater instruction manual.

Install or clean the spray tips

Air compressor: Follow manufacturer’s recommendations.

Stop spraying · 7 308647

Page 8 of the Graco 238892 user manual — Cleaning the Regulator
Page 8 · click to enlarge
Page 8

Operation

Adjusting the System Pressure

2. Adjust the pump air pressure and fluid regulator for the desired spray pattern. Use the lowest possible air and fluid pressures for your application. For optimum performance, the inbound fluid pressure should be at least 500 psi (3.4 MPa, 34 bar) above the regulated fluid pressure.

CAUTION

The new system must be cleaned and tested thoroughly before admitting fluid to the regulator to avoid contaminants clogging or damaging the regulator.

Always use the lowest possible air and fluid pressures for your application. High pressures can cause premature spray tip, regulator, and pump wear.

For example: With 3500 psi (24.5 MPa, 245 bar) to the regulator, the minimum regulated outlet pressure would be 1500 psi (10.5 MPa, 105 bar).

NOTES:

The fluid pressure regulator controls pressure downstream from its outlet.

3. In a circulating system, also adjust the back pressure valve (K).

If you are using an accessory fluid pressure gauge (H in Fig. 1), relieve the spray gun line pressure after you reduce the regulator pressure to ensure a correct gauge reading.

4. Record all the settings for future reference.

Cleaning the Regulator

1. Make a note of the proper way to adjust pressure, from the following descriptions:

Do not allow fluid to settle in the system.

Flush the regulator whenever the rest of the system is flushed (see page 9). Before you flush the system, follow the Pressure Relief Procedure on page 7, then completely decrease the regulated fluid pressure. See step 1 in Adjusting the System Pressure, at left.

On a spring-operated regulator, turn the adjusting screw (10) counterclockwise to decrease pressure and clockwise to increase pressure to the spray gun or extruder gun.

Before you remove the regulator for thorough cleaning and inspection, follow the Pressure Relief Procedure on page 7. Then remove the regulator, clean it, and inspect all parts.

On an air-operated regulator, increase supply air pressure to increase fluid pressure. Decrease supply air pressure to decrease fluid pressure. Supply air up to 100 psi (0.7 MPa, 7 bar). See the chart on page 20 for air versus fluid pressure.

8 308647

Page 9 of the Graco 238892 user manual — Flushing
Page 9 · click to enlarge
Page 9

Operation

Flushing

4. Open the fluid regulator fully.

Flush before changing colors, before fluid can dry in the equipment, at the end of the day, before storing, and before repairing equipment.

a. Spring Operated Regulators Only: Open the fluid regulator by turning the adjusting screw (10) fully clockwise.

Flush at the lowest pressure possible. Check connectors for leaks and tighten as necessary.

b. Air Operated Regulator Only: Increase the air regulator setting to fully open the fluid regulator. You will have to reset the fluid regulator’s pressure setting after flushing.

Flush with a fluid that is compatible with the fluid being dispensed and the equipment wetted parts.

5. Supply solvent to the system. Set pump to the lowest possible pressure, and start pump.
1. Record the pressure adjustment setting of the fluid regulator before flushing.
6. Flush until thoroughly clean.
2. Shut off the pump and relieve fluid pressure in the system by triggering the gun and opening the back pressure regulator or other bypass valve.
7. Adjust the fluid regulator to the desired setting.

a. Spring Operated Regulators Only: Turn the adjustment screw (10) counterclockwise to return to the desired pressure setting.

3. Never exceed the maximum working pressure of the lowest rated system component. Remove the gauge if the flushing pressure will exceed the gauge range.

b. Air Operated Regulator Only: Adjust the air regulator to return to the desired fluid pressure setting.

9 308647

Page 10 of the Graco 238892 user manual — Troubleshooting
Page 10 · click to enlarge
Page 10

Troubleshooting

To reduce the risk of serious bodily injury, including skin injection, splashing in the eyes or on the skin, or injury from moving parts, always follow the Pres- sure Relief Procedure on page 5 whenever the pump is shut off, before installing, cleaning, adjust- ing, removing, or servicing the valve or any part of the system, and whenever you stop dispensing.

ProblemCauseSolution No pressure regulationDamaged diaphragm Leaking or dirty seatReplace diaphragm. Replace cartridge, or clean seat. No fluid flowDamaged valve actuatorReplace valve actuator. Pressure creeps above settingMetal chip or contamination between ball and seat Damaged diaphragm Damaged o-ring or improper seal Damaged or clogged air regulator or line (air-operated regulator only) Leaking or dirty seat Large change in inlet pressureReplace cartridge, or clean seat area. Replace diaphragm. Replace the o-ring under the seat. Clear obstruction in line. Service regulator if necessary. Replace cartridge, or clean seat. Stabilize regulator inlet pressure. Pressure drops below settingEmpty/clogged supply line Damaged or clogged air regulator or line (air-operated regulator only) Using valve beyond its rated flow capacity Large change in inlet pressureFill/flush supply line. Clear obstruction in line. Service regulator if necessary. Install valve for each spray gun or dispensing valve. Stabilize regulator inlet pressure. Fluid leaks from spring housingLoose fluid housing Damaged diaphragmTighten the four cap screws. Replace diaphragm. ChatterExcessive pressure differential between pump and gun Excessive flow rateReduce pump pressure to not more than 2000 psi (14 MPa, 138 bar) greater than required gun pressure. Reduce fluid flow through regulator. Connect only one spray gun or dispensing valve to each fluid regulator.

10 308647

Page 11 of the Graco 238892 user manual — Service Kits
Page 11 · click to enlarge
Page 11

Service

Service Kits

Installing the Air-Operated Conversion Kit (See Parts Drawings on pages 14–16)

For the Fluid Diaphragm Repair Kit, order Part 238747. Parts included in this kit are marked with an asterisk, for example (7*), in the Parts Drawings and Lists on pages 14 and 16.

1. Relieve the pressure.

For the Cartridge Repair Kit, order Part 238748 for all models except 248090. Parts included in this kit are marked with a dagger, for example (3), in the Parts Drawings and Lists on pages 14 and 16.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.

For the Cartridge Repair Kit for 248090, order Part 248098. Parts included in this kit are marked with a checkmark, for example (3), in the Parts Drawings and Lists on pages 14 and 16.

2. On the spring-operated regulator, turn the adjusting screw (10) counterclockwise until it is loose enough to fully relieve the spring tension.
3. Use a strap wrench or an equivalent wrench to loosen and remove the spring cover (2), spring retainers (6 and 27), and spring (11).

To convert from a spring-operated to an air-operated regulator, order the Air-Operated Conversion Kit, Part 238749. Parts included in this kit are marked with a double dagger, for example (37), in the Parts Drawings and Lists on pages 14 and 16.

4. Place the stabilizing spring (22) of the air-operated regulator on the piston rod (6). Install the conversion kit assembly onto the backing plate (8). Torque to 15 to 20 ft-lb (20 to 27 N m).
5. Plumb an air line up to the 1/4 npt(m) threads of the nipple (35) on the air regulator.
6. Flush the system (see page 9), and set the regulator pressure by following the procedure in Adjusting the System Pressure on page 8.

11 308647

Page 12 of the Graco 238892 user manual — Replacing the Fluid Diaphragms
Page 12 · click to enlarge
Page 12

Service

Replacing the Fluid Diaphragms

6. Remove the o-ring (17) from the groove in the base housing (4), clean and inspect the base housing, and replace if necessary.

See Fig. 3, and follow the steps below. For parts that are not called out in Fig. 3, see the Parts Drawing on page 14.

7. Install a new o-ring (17) in the groove in the base housing (4).
1. Relieve the pressure , and remove the regulator from the fluid line.
8. Lightly lubricate the backing plate (8) bore and plunger (7) with a lithium-based grease.
9. Install the new, pre-assembled diaphragm subassembly into the backing plate (8).

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.

2. Turn the adjusting screw (10) counterclockwise until it is loose to fully relieve the spring tension.
10. Align the holes in the diaphragms with the backing plate (8).
3. Remove the four base housing screws (9) from the base housing (4), and pull the base housing free of the backing plate (8).
11. Install the backing plate/diaphragms assembly over the base housing (4). Hold the backing plate (8) tightly against the base housing, and install the four base housing screws (9).
4. Remove the diaphragm and valve actuator subassembly (1, 7, 12, 13, and 19).
12. Torque the base housing screws (9) first to 20 to 25 ft-lb (27 to 34 N m), then to 30 to 35 ft-lb (41 to 48 N m) in the sequence shown in Fig. 3.
5. Clean and inspect the bore in the backing plate (8) for wear, and replace it if necessary.

Torque Sequence for Regulator

Base Housing Screws (9)

Show 5 more labels / short text on this page
backing plate (8) · cartridge assembly diaphragm · and valve · actuator subassembly · 12 308647
Page 13 of the Graco 238892 user manual — CAUTION
Page 13 · click to enlarge
Page 13

Service

Replacing the Cartridge

See Fig. 3, and follow the steps below. For parts that are not called out in Fig. 3, see the Parts Drawing on page 14.

3. Inspect and clean the internal walls of the base housing (4).

CAUTION

Handle the hard carbide parts, which are the ball (16), valve actuator (1), and valve seat (14), carefully to avoid damaging them.

4. Re-torque the retaining nut (3) to 140 to 160 in-lb (16 to 18 N m).
1. Relieve the pressure.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.

5. Install the new cartridge assembly in the base housing (4), and torque the valve housing (5) to 30 to 35 ft-lb (41 to 48 N m).
2. Remove the cartridge assembly by loosening the valve housing (5) with a 6 mm hex wrench and pulling the cartridge assembly out of the base housing (4).

13 308647

Page 14 of the Graco 238892 user manual — Parts Drawing Models 238889, 238890, 238891, and 238892
Page 14 · click to enlarge
Page 14

Parts Drawing Models 238889, 238890, 238891, and 238892

238889 with EZ Flush gauge port plug 238890 with fluid pressure gauge

238891 with EZ Flush gauge port plug 238892 with fluid pressure gauge

500 to 3000 psi (3.4 to 21 MPa, 34 to 207 bar) Regulated Fluid Outlet Pressure

3000 to 5000 psi (21 to 34 MPa, 207 to 345 bar) Regulated Fluid Outlet Pressure

DETAIL Torque Sequence for Regulator

1 Torque to 25 to 30 in-lb (2.8 to 3.4 Nm).

Base Housing Screws (9)

Torque to 140 to 160 in-lb (16 to 18 Nm).

Torque to 10 to 20 ft-lb (14 to 27 Nm).

Torque to 30 to 35 ft-lb (41 to 48 Nm).

Torque first to 20 to 25 ft-lb (27 to 34 Nm), then to 30 to 35 ft-lb (41 to 48 Nm) in the sequence shown in DETAIL at left.

6 Apply lithium-based grease when reassembling.

7 Apply a fluid-compatible grease to aid in reassembly.

Show 17 more labels / short text on this page
Spring-Operated Regulator · Spring-Operated Regulator · 7* · 12* · 13* · 19* · 1* · 17* · 3 · 14 · 15 · 20 · 18 · 16 · 21 · 5 · 14 308647
Page 15 of the Graco 238892 user manual — Parts List Models 238889, 238890, 238891, and 238892
Page 15 · click to enlarge
Page 15

Parts List Models 238889, 238890, 238891, and 238892

Ref. Part No. Description Qty.

Ref. Part No. Description Qty.

1 * ACTUATOR 1 2 238858 COVER, spring 1 3 191577 NUT, spring retainer 1 4 191578 BASE HOUSING; sst 1 5 191579 VALVE HOUSING; sst 1 6 191580 RETAINER, spring, guide 1 7 * PLUNGER, spring 1 8 191583 PLATE, backing 1 9 113623 BASE HOUSING SCREW, cap, socket-head; M10 x 1.5 x 70 4 10 113624 ADJUSTING SCREW, cap, socket-head; M8 x 1.25 x 45 1 11 113625 SPRING, compression; red for Models 238889 & 238890 1 113626 SPRING, compression; yellow for Models 238891 & 238892 1 12 * DIAPHRAGM, regulator; TPE cream colored 1 13 * DIAPHRAGM, regulator; PTFE white 1 14 191914 SEAT, valve 1 15 113651 O-RING, packing; PTFE 1 16 112365 BALL 1 17* 109213 O-RING, packing; PTFE 025 1

18 107079 O-RING, packing; PTFE 019 1 19 * O-RING, packing; PTFE 013 1 20 109450 O-RING, packing; PTFE 016 1 21 111858 SPRING, compression 1 23 113634 WRENCH, hex; 6 mm (not shown) 1 27 191919 RETAINER, spring, sleeve 1 28 113641 GAUGE, pressure for Model 238890 1 113654 GAUGE, pressure for Model 238892 1 29 238896 PLUG, EZ Flush (includes Ref. 30) for Models 238889 & 238891 1 30 107509 O-RING, packing; PTFE 007 1

* Included in Fluid Diaphragm Repair Kit 238747

Included in Cartridge Repair Kit 238748

To convert to a higher or lower pressure range, order one of the following compression springs: 113625 500 to 3000 psi (3.4 to 21 MPa, 34 to 207 bar 113626 3000 to 5000 psi (21 to 34 MPa, 207 to 345 bar)

15 308647

Page 16 of the Graco 238892 user manual — Parts Drawing Models 238893, 238894, 248090, and 255072
Page 16 · click to enlarge
Page 16

Parts Drawing Models 238893, 238894, 248090, and 255072

238893 with EZ Flush gauge port plug 238894 with fluid pressure gauge 248090 with fluid pressure gauge for LASD material 255072 High Resolution

Graco 238892 — Parts Drawing Models 238893, 238894, 248090, and 255072 diagram (page 16)
Fig. 1 · Parts Drawing Models 238893, 238894, 248090, and 255…

100 psi (0.7 MPa, 7 bar) Maximum Inbound Air Pressure

500 to 4000 psi (3.4 to 28 MPa, 34 to 276 bar) Regulated Fluid Outlet Pressure

Torque to 25 to 30 in-lb (2.8 to 3.4 Nm).

Torque to 140 to 160 in-lb (16 to 18 Nm).

Graco 238892 — Parts Drawing Models 238893, 238894, 248090, and 255072 diagram (page 16)
Fig. 2 · Parts Drawing Models 238893, 238894, 248090, and 255…

Torque to 15 to 20 ft-lb (20 to 27 Nm).

Torque to 30 to 35 ft-lb (41 to 48 Nm).

Torque first to 20 to 25 ft-lb (27 to 34 Nm), then to 30 to 35 ft-lb (41 to 48 Nm) in the sequence shown in DETAIL at left.

6 First torque to 30–33 in-lb (3.4–3.7 Nm) in alternating pattern then torque to 68–72 in-lb (7.7–8.1 Nm) in alternating pattern.

7 Apply lithium-based grease when reassembling.

Torque to 75 to 80 in-lb (8.4 to 9.0 Nm).

16 308647

Page 17 of the Graco 238892 user manual — Parts List Models 238893, 238894, 248090, and 255072
Page 17 · click to enlarge
Page 17

Parts List Models 238893, 238894, 248090, and 255072

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

1 * ACTUATOR 1 2 191584 HOUSING ADAPTER 1 3 191577 NUT, spring retainer 1 4 191578 HOUSING, base, for Models 238893 and 238894 1 197952 HOUSING, base, for Model 248090 1 15J923 HOUSING, base, for Model 255072 1 5 191579 VALVE HOUSING, sst 1 15J924 VALVE HOUSING, for Model 255072 1 6 191585 ROD, piston, for Models 238893, 238894, and 248090 1 15J920 ROD, piston, for Model 255072 1 7 * PLUNGER, spring 1 8 191583 PLATE, backing 1 9 113623 BASE HOUSING SCREW, cap, socket-head; M10 x 1.5 x 70 4 11 114104 SCREW, machine 12 12 * DIAPHRAGM, regulator; TPE cream colored 1 13 * DIAPHRAGM, regulator; PTFE 1 white 1 14 191914 SEAT, valve 1 15 113651 O-RING, packing; PTFE 1 16 112365 BALL, for Models 238893 and 238894 1 16 15D092 BALL, for Models 248090 and 255072 1 17* 109213 O-RING, packing; PTFE 025 1 18 107079 O-RING, packing; PTFE 019 1 19 * O-RING, packing; PTFE 013 1 20 109450 O-RING, packing; PTFE 016 1

21 111858 SPRING, compression 1 22 160062 SPRING, stabilizing 1 25 113654 GAUGE, pressure for Models 238894 and 248090 1 28 ––– COVER, diaphragm 1 29 ––– HOUSING, diaphragm 1 30 100326 SCREW, machine 1 31 110341 REGULATOR, air 1 32 100403 PLUG, pipe 1 33 108190 GAUGE, pressure, air 1 34 103656 NIPPLE, pipe, hex 1 35 151519 NIPPLE, reducing; 1/4 x 1/8 npt 1 36 192194 WASHER, support 1 15J921 WASHER, for Model 255072 1 37 180979 DIAPHRAGM; nylon, for Models 238893, 238894, and 248090 1 38 238896 PLUG, EZ Flush (includes Ref. 39) for Model 238893 1 39 107509 O-RING, packing; PTFE 007 for Model 238893 1 40 15J922 RING, diaphragm, for Model 255072 1 41 198241 PLUG, pressure for Models 248090 and 255072 2 42 111457 PACKING, o-ring; PTFE 012 for Models 248090 and 255072 2

* Included in Fluid Diaphragm Repair Kit 238747

Included in Cartridge Repair Kit 238748

Included in Air-Operated Conversion Kit 238749

Included in Cartridge Repair Kit 248098

Included in Diaphragm Housing Repair Kit 16P596.

17 308647

Page 18 of the Graco 238892 user manual — TI1373
Page 18 · click to enlarge
Page 18

Parts Drawing

Model 244734

244734 with EZ Flush gauge port plug

Air-Operated Regulator, Full Range

100 psi (0.7 MPa, 7 bar) Maximum Inbound Air Pressure

500 to 4000 psi (3.4 to 28 MPa, 34 to 276 bar) Regulated Fluid Outlet Pressure

Torque to 25 to 30 in-lb (2.8 to 3.4 Nm).

Torque to 140 to 160 in-lb (16 to 18 Nm).

Torque to 15 to 20 ft-lb (20 to 27 Nm).

Torque to 30 to 35 ft-lb (41 to 48 Nm).

TI1373

First torque to 30–33 in-lb (3.4–3.7 Nm) in alternating pattern then torque to 68–72 in-lb (7.7–8.1 Nm) in alternating pattern.

DETAIL Torque Sequence for Regulator

Base Housing Screws (9)

2 6 Apply lithium-based grease when reassembling.

Torque first to 20 to 25 ft-lb (27 to 34 Nm), then to 30 to 35 ft-lb (41 to 48 Nm) in the sequence shown in DETAIL at right. 7

8 Torque to 75 to 80 in-lb (8.4 to 9.0 Nm).

Show 23 more labels / short text on this page
11 · 28 · 37 · 30 · 36 · 7* · 29 · 12* · 13* · 19* · 1* 2 · 17* · 6 · 22 · 3 · 14 · 15 · 20 · 18 · 16 · 21 · 5 · 18 308647
Page 19 of the Graco 238892 user manual — Parts List Model 244734
Page 19 · click to enlarge
Page 19

Parts List Model 244734

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

1 * ACTUATOR 1 2 191584 HOUSING ADAPTER 1 3 191577 NUT, spring retainer 1 4 197952 REGULATOR HOUSING 1 5 191579 VALVE HOUSING; sst 1 6 191585 ROD, piston 1 7 * PLUNGER, spring 1 8 191583 PLATE, backing 1 9 113623 BASE HOUSING SCREW, cap, socket-head; M10 x 1.5 x 70 4 11 114104 SCREW, machine; 1/4–20 x 1.0 12 12 * DIAPHRAGM, regulator; PTE cream colored 1 13 * DIAPHRAGM, regulator; PTFE white 1 14 191914 SEAT, valve 1 15 113651 O-RING, packing; PTFE 1 16 15D092 BALL 1 17* 109213 O-RING, packing; PTFE 025 1

18 107079 O-RING, packing; PTFE 019 1 19 * O-RING, packing; PTFE 013 1 20 109450 O-RING, packing; PTFE 016 1 21 111858 SPRING, compression 1 22 160062 SPRING, stabilizing 1 28 ––– COVER, diaphragm 1 29 ––– HOUSING, diaphragm 1 30 100326 SCREW, machine; 1/4–20 x 1/2 1 36 192194 WASHER, support 1 37 180979 DIAPHRAGM; nylon 1 38 238896 PLUG, EZ Flush (includes Ref. 39)1 39 107509 O-RING, packing; PTFE 007 1 40 198171 FITTING, elbow 1 41 198241 PLUG, pressure 2 42 111457 PACKING, o-ring; PTFE 012 2

* Included in Fluid Diaphragm Repair Kit 238747

Included in Cartridge Repair Kit 248098

Included in Air-Operated Conversion Kit 238749

Included in Diaphragm Housing Repair Kit 16P596.

19 308647

Page 20 of the Graco 238892 user manual — Air Requirements for Air-Operated Regulators (Models 238893, 238894, 248090, and 255072)
Page 20 · click to enlarge
Page 20

Technical Data

Model 238890 spring operated, with fluid pressure gauge M d l 238889

Model 244734 air operated, with pressure sensor ports Model 238889 spring operated, with EZ Flush plug

Model 238892 spring operated, with fluid pressure gauge M d l 238891

Models 238894, 248090, and 255072 air operated, with fluid pressure gauge

Model 238891 spring operated, with EZ Flush plug

Model 238893 air operated, with EZ Flush plug

Maximum fluid inlet pressure

6000 psi (41 MPa, 414 bar)

6000 psi (41 MPa, 414 bar)

6000 psi (41 MPa, 414 bar)

6000 psi (41 MPa, 414 bar)

Regulated fluid outlet pressure range

500–3000 psi (3.4–21 MPa, 34–207 bar)

3000–5000 psi (21–34 MPa, 207–345 bar)

500–4000 psi (3.4–28 MPa, 34–276 bar)

500–4000 psi (3.4–28 MPa, 34–276 bar)

Maximum inbound air pressure

–– –– 100 psi (0.7 MPa, 7 bar)

100 psi (0.7 MPa, 7 bar)

3/8 npt(f) 3/8 npt(f) 3/8 npt(f) 1/2 npt(f) for 248090 1/2 npt(f)

Gauge port size 1/4 npt(f) 1/4 npt(f) 1/4 npt(f) 1/4 npt(f)

Fluid pressure gauge (Models 238890, 238892, and 238894)

0–3000 psi (0–21 MPa, 0–207 bar)

0–5000 psi (0–34 MPa, 0–345 bar)

0–5000 psi (0–34 MPa, 0–345 bar)

Maximum flow (in 65 cp material)

2 gpm (7.6 lpm) 2 gpm (7.6 lpm) 2 gpm (7.6 lpm) 2 gpm (7.6 lpm)

up to 15,000 cp up to 15,000 cp up to 15,000 cp up to 15,000 cp

120 F (50 C) 120 F (50 C) 120 F (50 C) 120 F (50 C)

Weight (with gauge) 7.0 lb (3.2 kg) 7.0 lb (3.2 kg) 11.7 lb (5.3 kg) 11.7 lb (5.3 kg)

Fluid diaphragms PTFE with TPE backing

PTFE with TPE backing

PTFE with TPE backing

PTFE with TPE backing

Wetted parts (all models)

304, 316, 17–4 passivated SST, nickel– and cobalt–bound tungsten carbide, PTFE for all models; ceramic for model 248090, 244734, and 255072 only.

Adjustment tool (spring-operated models)

6 mm hex wrench 6 mm hex wrench –– ––

Air Requirements for Air-Operated Regulators (Models 238893, 238894, 248090, and 255072)

The following table shows the approximate air pressure needed to regulate the air-operated regulator to a given fluid outlet pressure.

Regulated Fluid Outlet Pressure

and 255072 Model 255072

psi MPa bar psi MPa bar psi MPa bar

28 0.19 1.9 1000 7 69 550 4 40

49 0.34 3.4 2000 14 138 1150 8 80

70 0.48 4.8 3000 21 207 1800 12 120

90 0.62 6.2 4000 28 276 2450 17 170

100 0.68 6.8 4000 28 276 2700 19 190

Show 8 more labels / short text on this page
fluid pressure gauge · ports · Fluid inlet/outlet size · Maximum fluid viscosity · Maximum operat- ing temperature · Models 238894, 248090, · Air Pressure · 20 308647
Page 21 of the Graco 238892 user manual — FLUID FLOW
Page 21 · click to enlarge
Page 21

Performance Chart

Fluid Pressure Regulators, Models 238889 through 238894 and 248090

REGULATED (outbound) FLUID PRESSURE

gpm (lpm) (1.9)

0.0 0.5 1.0 1.5 2.0

(3.8) (5.7) (7.6)

FLUID FLOW

Test Conditions Regulators tested in oil at 70 F (21 C) and at 6000 psi (41 MPa, 414 bar) inbound fluid pressure.

65 cp oil 3000 cp oil

Show 9 more labels / short text on this page
psi (MPa, bar) · (41, 414) · (34, 345) · (28, 276) · (21, 207) · (14, 138) · (7, 69) · Key · 21 308647
Page 22 of the Graco 238892 user manual — Notes
Page 22 · click to enlarge
Page 22

Notes

22 308647

Page 23 of the Graco 238892 user manual — TI1372
Page 23 · click to enlarge
Page 23

Dimensional Drawings

Models 238889 and 238891 with port plug Models 238890 and 238892 with gauge (spring operated)

3/8 npt inlet port

A Height8.9 in. (225 mm)
B Diameter of base housing2.65 in. (70 mm)

A

B

1/4–20 UNC mounting holes, 1/2 in. (12 mm) deep (both sides)

Model 238893 with port plug Model 238894 with gauge Models 248090 and 255072 with gauge and 1/2 npt inlet and outlet ports (air operated)

Model 244734 (air operated)

A Height8.1 in. (206 mm)
A Height10.0 in. (254 mm)
B Diameter of diaphragm cover7.0 in. (179 mm)
B Diameter of diaphragm cover7.0 in. (179 mm)

3/8 npt (1/2 npt for

B

B

A

A

3/8 npt (1/2 npt for 248090)

TI1372

1/2 npt inlet port

outlet port 1/4 npt gauge port

1/4–20 UNC mounting holes, 1/2 in. (12 mm) deep (both sides)

1/4–20 UNC mounting holes, 1/2 in. (12 mm) deep (both sides)

Show 8 more labels / short text on this page
3/8 npt outlet · port · 1/4 npt gauge · port · 1/2 npt outlet · 248090) inlet port · port · 23 308647
Page 24 of the Graco 238892 user manual — Graco Information
Page 24 · click to enlarge
Page 24

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com

TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers

to identify the distributor closest to you:

1–800–328–0211 Toll Free 612–623–6921 612–378–3505 Fax

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

For patent information, see www.graco.com/patents

Original instructions. This manual contains English. MM 308647

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea

GRACO INC. AND SUBSIDIARIES P.O. BOX 1441 MINNEAPOLIS MN 55440–1441 USA

Copyright 1997, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com

Revised April 2012 · 24 308647

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
No pressure regulationDamaged diaphragm Leaking or dirty seatReplace diaphragm. Replace cartridge, or clean seat. p.10
No fluid flowDamaged valve actuatorReplace valve actuator. p.10
Pressure creeps above settingMetal chip or contamination between ball and seat Damaged diaphragm Damaged o-ring or improper seal Damaged or clogged air regulator or line (air-operated regulator only) Leaking or dirty seat Large change in inlet pressureReplace cartridge, or clean seat area. Replace diaphragm. Replace the o-ring under the seat. Clear obstruction in line. Service regula- tor if necessary. Replace cartridge, or clean seat. Stabilize regulator inlet pressure. p.10
Pressure drops below settingEmpty/clogged supply line Damaged or clogged air regulator or line (air-operated regulator only) Using valve beyond its rated flow capacity Large change in inlet pressureFill/flush supply line. Clear obstruction in line. Service regula- tor if necessary. Install valve for each spray gun or dispensing valve. Stabilize regulator inlet pressure. p.10
Fluid leaks from spring housingLoose fluid housing Damaged diaphragmTighten the four cap screws. Replace diaphragm. p.10
ChatterExcessive pressure differential between pump and gun Excessive flow rateReduce pump pressure to not more than 2000 psi (14 MPa, 138 bar) greater than required gun pressure. Reduce fluid flow through regulator. Connect only one spray gun or dispens- ing valve to each fluid regulator. p.10

Ask about the Graco 238892

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco 238892

Be the first to ask — other owners or our team will answer.

Original document

Graco 238892 manual PDF

24 pages·328 KB·Marine Instruments·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…