Instruction/ maintenance manual of the product GPH 13 H Goodmans
Go to page of 28
• Refer to Service Manual RS6300011 (Horizontal) for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information.
PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit.
PRODUCT IDENTIFICA TION 3 GPH1324H41AB GPH1330H41AB GPH1336H41AC GPH1342H41AB GPH1348H41BB GPH1360H41BB The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
4 PRODUCT DESIGN GPH Package Units are designed for outdoor installations only in either residential or light commercial applications. The connecting ductwork (Supply and Return) can only be connected for horizontal airflow.
PRODUCT DESIGN 5 36" 36" 24" P L E N U M U N I T P L A T F O R M C U R B Rooftop Installation - Horizontal (H) NOTE: To ensure proper condensate drainage, unit must be installed in a level position.
6 PRODUCT DESIGN ELECTRICAL DA T A (*Blower Only , Heat Mode) All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur.
PRODUCT DIMENSIONS 7 34.075 66.5 42 4. 51 2 14 . 0 00 14 . 0 00 SUP PLY 6.50 0 RE TU RN 4.500 BACK VI EW (DUC T O PENI NGS ) A 14 . 0 00 B GPH13[24-60]H41** Ch as s i s M o d el A B GP H13 24H 41* * 22 . 0 00 29 . 932 GP H13 30H 41* * 22 . 0 00 29 . 932 GP H13 36H 41* * 24 .
P ACKAGE HEA T PUMP SPECIFICA TIONS 8 GPH13[24-36]H41AB GPH1336H41AC (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min.
P ACKAGE HEA T PUMP SPECIFICA TIONS 9 (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes.
ACCESSORIES 10 P a rt Nu m b e r De s cr i p t i on O T 18- 60 A O ut door T her mosta t Ki t w /Loc kout S tat O T /EHR18-60 Em e r genc y Heat Rel ay K i t HKR E l ectr ic H eat Ki t PCCP101- 103 Ro.
BLOWER PERFORMANCE DA T A 11 Dry Coil Data NOTES: 1. Data shown is Dry Coil. Wet Coil Pressure Drop is approximate. 2. 0.1" H 2 O, for 2 row indoor coil; 0.2” H 2 O, for 3 row indoor coil; and 0.3” H 2 O, for 4 row indoor coil. 3. Data shown does not include filter pressure drop, approx.
12 BLOWER PERFORMANCE DA T A 30 40 50 60 70 80 90 110 1 2 0 100 13 0 140 15 0 100 90 80 70 60 50 40 30 20 10 OUT P U T B TU/ H R x 10 0 0 BT U OUTPUT vs TEMPERAT URE RISE CHART TEMPERAT URE RISE 600 C FM 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C FM FORMULA S BTU OUTPUT = CFM x 1.
13 COOLING PERFORMANCE DA T A GPH1324H41** MOD EL: GP H 1324H41* * EX PAN DE D P ER F O R M ANC E D ATA COOLIN G OP E RA TION De sign S ub c ool i ng , 1 2 ±3 °F @ t he li q ui d ac c es s f i tt ing c on nec tio n AHRI 9 5 t e st c o ndi ti ons. Des i gn Superhe a t 8 ±3 °F @ the c o mp r e s s or s uc tion a c cess fit ting c onne c t i on.
14 COOLING PERFORMANCE DA T A GPH1324H41** MOD EL: GP H 1324H41** EX PAN DE D P ER FO R M ANC E D ATA COOLIN G OP E RATION De sign Subc ool i ng , 12 ±3 °F @ the l i q ui d a cces s f i tt i ng connecti o n AHRI 95 t e st c o nd i ti ons. Des i g n Supe rhea t 8 ±3 °F @ the c om pr e s s or suction acc e ss fit ting c onne ct i on.
15 COOLING PERFORMANCE DA T A GPH1330H41** MOD E L : GP H 1330H41* * E XP A ND ED PE RF O RM A N CE DA T A C OOLIN G OP E R ATION De s i gn S ubc ooli ng , 1 2 ± 3 °F @ the li quid ac c e s s f i tt i ng co nne c tion AH RI 95 t es t c o nditions .
16 COOLING PERFORMANCE DA T A GPH1330H41** MOD E L : GP H 1330H41* * E XP A ND ED PE RF O RM A N CE DA T A C OOLIN G OP E R ATION De s i gn S ubc ooli ng , 1 2 ± 3 °F @ the li quid ac c e s s f i tt i ng co nne c tion AH RI 95 t es t c o nditions .
17 COOLING PERFORMANCE DA T A GPH1336H41** MOD E L : GP H 1336H41* * E XP A ND E D PE RF ORMA N CE DA TA C OOL IN G OP E RATION De s i gn Subc oo l i n g , 1 2 ±3 °F @ the liqui d ac c es s f i tt ing c o nnec ti on AHRI 9 5 t es t c o ndi ti o ns.
18 COOLING PERFORMANCE DA T A GPH1336H41** MOD E L: GP H 1336H41** E XP A ND ED PE RF ORM A N CE DA T A COOL IN G OP E RATI O N De sign Subc o ol i ng , 12±3 °F @ the l i q ui d ac c es s f it t i n g conne c tio n AHRI 9 5 t es t c o ndi tion s.
19 COOLING PERFORMANCE DA T A GPH1342H41** MOD EL: GP H 1342 H41** EX PAN DE D P ER F O R M ANC E D ATA CO O LI N G OP E RA T I O N De s ign S ub c oo ling , 1 2± 3 °F @ t he li qu id a c ce s s f i t t i ng c on ne ct ion A R I 9 5 t e s t con d it ion s .
20 COOLING PERFORMANCE DA T A GPH1342H41** MOD E L : GP H 1342H41** EX PAN DE D P ER F O R M ANC E D ATA C OOL ING OP ER AT I ON De sig n Subc oo l i ng , 12 ±3 ° F @ the l i q ui d ac c es s f i tt i n g c onnec ti on AHRI 95 t es t c o ndi tio ns.
21 COOLING PERFORMANCE DA T A GPH1348H41** M O DE L: G PH1 3 4 8 H 4 1 ** EX PAN DE D P ER F O R M AN C E D ATA COO LIN G O P E RAT ION De s i gn S ubc ooli ng , 1 2 ±3 °F @ the l i qui d a c c e ss f i tt i ng c onne c tion AHRI 95 t es t c o n di ti o ns.
22 COOLING PERFORMANCE DA T A GPH1348H41** M O DE L: G PH1 3 4 8 H 4 1 ** EX PAN DE D P ER F O R M AN C E D ATA COO LIN G O P E RAT ION De s i gn S ubc ooli ng , 1 2 ±3 °F @ the l i qui d a c c e ss f i tt i ng c onne c tion AHRI 95 t es t c o n di ti o ns.
23 COOLING PERFORMANCE DA T A GPH1360H41** MOD E L : GP H 1360H41 * * EX PAN DE D P ER F O R M ANC E D ATA C OOL ING OP ER AT IO N D esi g n Su b co o l i n g , 12 ±3 ° F @ th e l iq u i d acc ess f itt in g co n n ec ti o n A H R I 95 t est c ond i t i o n s.
24 COOLING PERFORMANCE DA T A GPH1360H41** MOD E L : GP H 1360H41** E X P A ND ED PE RF ORM A N CE DA T A C O OL I NG OP ER AT IO N D esi g n Su b co o l i n g, 12 ±3 ° F @ t h e l iq u i d ac c ess f itt in g co n n ec ti o n A H R I 95 t est c o n d i ti o n s.
P ACKAGE HEA T PUMP SPECIFICA TIONS 25 GPH13[24-36]H41** E X PAN D ED PE RFO R M AN CE DAT A MOD E L : G P H 1324H 41* H E AT ING OPE RA TION O utdoor Am bi e nt Te m pera tur e 65 60 55 50 47 45 40 35 30 25 20 17 1 5 1 0 5 0 - 5 -10 M B h 2 7 . 72 6 .
P ACKAGE HEA T PUMP SPECIFICA TIONS 26 PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1.
WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 27 WARN I NG HIGH V OLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OUR CES M AY BE PRESEN T.
28 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. WARN I NG HIGH V OLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OUR CES M AY BE PRESEN T.
An important point after buying a device Goodmans GPH 13 H (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Goodmans GPH 13 H yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Goodmans GPH 13 H - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Goodmans GPH 13 H you will learn all the available features of the product, as well as information on its operation. The information that you get Goodmans GPH 13 H will certainly help you make a decision on the purchase.
If you already are a holder of Goodmans GPH 13 H, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Goodmans GPH 13 H.
However, one of the most important roles played by the user manual is to help in solving problems with Goodmans GPH 13 H. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Goodmans GPH 13 H along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center