Giant P423
Table of Contents 24 sections P400 Series - · Triplex Ceramic · Plunger Pump Operating Instructions/ Repair and Service Manual · 22 and 25mm Versions · … ShowHide
Page 1 of the Giant P423 user manual — Updated 11/07
Page 1 · click to enlarge
Page 1

P400 Series -

Triplex Ceramic

Plunger Pump Operating Instructions/ Repair and Service Manual

22 and 25mm Versions

For Models: P420 P420-0011 P420-0021 P422 P423 P425

Giant P423 — Triplex Ceramic diagram (page 1)
Fig. 1 · Triplex Ceramic
Giant P423 — Triplex Ceramic diagram (page 1)
Fig. 2 · Triplex Ceramic

Contents: Installation Instructions: page 2 Pump Specifications (except P425): pages 3-5 Exploded View: page 6 Parts List/Kits: page 7 Pump Specifications (P425): page 8 Repair Instructions/Torque Specs.: pages 9-10 Trouble Shooting Chart: page 11 Recommended Spare Parts List: page 11 Dimensions: back page Warranty Information: back page

Updated 11/07

Page 2 of the Giant P423 user manual — INSTALLATION INSTRUCTIONS
Page 2 · click to enlarge
Page 2

INSTALLATION INSTRUCTIONS

Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following informa- tion is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance.

4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsation. Dampeners can also reduce the severity of pressure spikes that occur in systems using a shut-off gun. A dampener must be positioned downstream from the unloader.
1. The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication.
5. Crankshaft rotation on Giant Industries, Inc. pumps should be made in the direction designated by the arrows on the pump crankcase. Reverse rotation may be safely achieved by following a few guidelines available upon request from Giant Industries, Inc. Required horsepower for system operation can be obtained from the charts on pages 3-5 and page 8.
2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joints. If pumps are to be operated at temperatures in excess of 160 0 F, it is important to insure a positive head to the pump to prevent cavitation.
6. Before beginning operation of your pumping system, remember: Check that the crankcase and seal areas have been properly lubricated per recommended schedules. Do not run the pump dry for extended periods of time. Cavitation will result in severe damage. Always remember to check that all plumbing valves are open and that pumped media can flow freely to the inlet of the pump.
3. The discharge plumbing from the pump should be properly sized to the flow rate to prevent line pressure loss to the work area. It is essential to provide a safety bypass valve between the pump and the work area to protect the pump from pressure spikes in the event of a blockage or the use of a shut-off gun.

Finally, remember that high pressure operation in a pump system has many advantages. But, if it is used carelessly and without regard to its potential hazard, it can cause serious injury.

Giant P423 — INSTALLATION INSTRUCTIONS diagram (page 2)
Fig. 3
1. Prior to initial operation, add oil to the crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL.
2. Pump operation must not exceed rated pressure, volume, or RPM. A pressure relief device must be installed in the discharge of the system.

Use SAE 80-90W or Giant’s p/n 01154 or ISO VG220 industrial gear lube oil

3. Acids, alkalines, or abrasive fluids cannot be pumped unless approval in writing is obtained before operation from Giant Industries, Inc.

Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.

4. Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures.
Page 3 of the Giant P423 user manual — Specifications ModelS P420A, P420A-0011, P420A-0021
Page 3 · click to enlarge
Page 3

Specifications ModelS P420A, P420A-0011, P420A-0021

U.S. (Metric) Volume Up to 12.9 GPM (48.8 LPM) Discharge Pressure Up to 2175 PSI (150 bar) Inlet Pressure -4.35 to 145 PSI (-.3 to 10 bar) Stroke 0.945” (24mm) RPM Up to 1450 RPM Plunger Diameter 0.98” (25mm) Temperature of Pumped Fluids Up to 160 oF (71 oC) Inlet Ports (2) 1" NPT Discharge Ports (2) 3/4" NPT Shaft Rotation Top of pulley towards fluid end Crankshaft Diameter 1.1” (28mm) Key Width 0.315” (8mm) Shaft Mounting Either side1

Weight 36 lbs. 11oz (16.6 kg) Crankcase Capacity 27 fl.oz (0.8 liters) Volumetric Efficiency @ 1450 (0.95) Mechanical Efficiency @ 1450 (0.86)

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P420 HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI1700 PSI2175 PSI 7857.04.87.28.210.4 9008.05.58.39.312.0 10109.06.29.310.513.4 11209.96.810.211.714.9 124011.07.611.412.816.5 145012.99.013.315.119.3

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:

The theoretical gallons per revolution (gal/rev) is 0.0089. To find specific outputs at various RPM, use the formula: GPM = 0.0089 x RPM

Page 4 of the Giant P423 user manual — Specifications
Page 4 · click to enlarge
Page 4

Specifications

Model P422

U.S. (Metric) Volume Up to 10.7 GPM (37.7 LPM) Discharge Pressure Continuous Up to 2600 PSI (180 bar) Discharge Pressure Intermittent Up to 3000 PSI (206.8 bar) Inlet Pressure -4.35 to 145 PSI (-.3 to 10 bar) Stroke 0.94” (24mm) RPM Up to 1450 RPM Plunger Diameter 0.87” (22mm) Temperature of Pumped Fluids Up to 160 oF (71 oC) Inlet Ports (2) 1" NPT Discharge Ports (2) 3/4" NPT Shaft Rotation Top of pulley towards manifold Crankshaft Diameter 1.102” (28mm) Key Width 315” (8mm) Shaft Mounting Either side1

Weight 36 lbs. 11oz (16.64 kg) CrankcaseCapacity 27 fl.oz (0.8 liters) Volumetric Efficiency @ 1450 (0.95) Mechanical Efficiency @ 1450 (0.83)

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P422 HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI2610 PSI3000 PSI* 9006.24.36.411.112.8 10507.25.07.513.014.9 11608.05.58.314.316.4 13009.06.29.316.018.4 145010.06.910.417.920.6

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:

The theoretical gallons per revolution (gal/rev) is 0.0069. To find specific outputs at various RPM, use the formula: GPM = 0.0069 x RPM

*Intermitent duty only*

Page 5 of the Giant P423 user manual — Specifications
Page 5 · click to enlarge
Page 5

Specifications

Model P423

U.S. (Metric) Volume Up to 8.3 GPM (31.4 LPM) Discharge Pressure Up to 2900 PSI (200 bar) Inlet Pressure -4.35 to 145 PSI (-.3 to 10 bar) Stroke 0.79” (20mm) RPM Up to 1450 RPM Plunger Diameter 0.87” (22mm) Temperature of Pumped Fluids Up to 160 oF (71 oC) Inlet Ports (2) 1" NPT Discharge Ports (2) 3/4" NPT Shaft Rotation Top of pulley towards manifold Crankshaft Diameter 1.102” (28mm) Key Width 315” (8mm) Shaft Mounting Either side1

Weight 36 lbs. 11oz (16.64 kg) CrankcaseCapacity 27 fl.oz (0.8 liters) Volumetric Efficiency @ 1450 (0.95) Mechanical Efficiency @ 1450 (0.83)

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P423HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI2000 PSI2900 PSI 9005.13.65.37.110.3 10506.04.16.28.212.0 11606.64.66.99.113.3 13007.45.17.710.214.9 14508.35.78.611.416.6

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:

The theoretical gallons per revolution (gal/rev) is 0.00572. To find specific outputs at various RPM, use the formula: GPM = 0.00572 x RPM

Page 6 of the Giant P423 user manual — EXPLODED VIEW - P420/P420-0011/P420-0021/ P422/ P423 AND P425 PUMPS
Page 6 · click to enlarge
Page 6

EXPLODED VIEW - P420/P420-0011/P420-0021/ P422/ P423 AND P425 PUMPS

Giant P423 — EXPLODED VIEW - P420/P420-0011/P420-0021/ P422/ P423 AND P425 PUMPS diagram (page 6)
Fig. 4
Page 7 of the Giant P423 user manual — P420/P420-0011/P420-0021/P422/P423 and P425 REPAIR KITS
Page 7 · click to enlarge
Page 7

P420/P420-0011/P420-0021/P422/P423 and P425 SPARE PARTS LIST

A = P420 B=P422 G=P423 H=P425 J=P420-0011 K=P420-0021

ITEM PART DESCRIPTION QTY. 1 08377 Crankcase 1 2 08378 Oil Fill Plug with Gasket 1 3 06479 Crankcase cover 1 3A 07186 Oil Sight Glass w/ Gasket 1 4 08380 O-Ring 1 5 07109 Oil Drain Plug 1 5A 07182 Gasket for Oil Drain Plug 1 5B 08092 Plug with Gasket 1 6 01010 Screw 4 6A 01011-0400 Spring Washer 4 7 05290 Bearing Cover Open 1 8 05291 Bearing Cover Closed 1 8A 05292 Shim 1 8B 05293 Shim (May not be present) 1 9 01016 O-Ring 2 10 07114 Screw with Washer 8 11 07459 Radial Shaft Seal 1 12 05350 Taper Roller Bearing 2 13 08475 Crankshaft (A, B, J & K) 1 13 08482 Crankshaft (G and H) 1 14 08091 Fitting Key 1 15 08390 Connecting Rod Assembly 3 15A 05349 Connecting Rod Screw 6 15B 05348 Adapter Sleeve 6 16 05351 Plunger Assy., 25mm, (A, H, and I) For items 16A-16H 3 16 05351-0001 Plunger Assy., 25mm, (J & K) For items 16A-16H 3 16 05353 Plunger Assy., 22mm, (B & G) For items 16A-16H 3 16A 05352 Plunger Base 3 16B 08398 Plunger Pipe, 25mm (A, H, J & K) 3 16B 06247 Plunger Pipe, 22mm (B and G) 3 16C 07256 Centering Sleeve 3 16D 08399 Tensioning Screw 3 16E 07023 O-Ring 3 16F 07203 Backup Ring 3 16G 07258 Copper Washer 3

ITEM PART DESCRIPTION QTY. 16H 06431 Oil Scraper 3 17 06790 Crosshead Pin 3 19 08366 Oil Seal 3 20 06771 Seal Case (A, H, J & K) 3 20 06770 Seal Case (B and G) 3 20A 06772 Gear Seal Adapter 3 21 07266 O-Ring (A, B, G, & H) 3 21 07266-0001 O-Ring, Viton (J & K) 3 22 08059 O-Ring (A, B, G, & H) 3 22 08059-0001 O-Ring, Viton (J & K) 3 23 12254 V-Sleeve, 25mm (A and H) 3 23 12254-0010 V-Sleeve, 25mm, Viton, (J) 3 23 12254-0020 V-Sleeve, 25mm, Teflon, (K) 3 23 06249 V-Sleeve with Support Ring, 22mm (B and G) 3 23A 06251 Spacer Ring (B and G) 3 23B 12255 Weep Seal (A and H) 3 23B 12255-0010 Weep Seal, Viton (J) 3 23B 12255-0020 Weep Seal, Teflon (K) 3 23B 13390 Weep Seal (B and G) 3 24 08376 Pressure Ring (A, H, J & K) 6 24 06252 Pressure Ring (B and G) 3 25 08394 Weep Return Ring (A, H, J & K) 3 25 06254 Weep Return Ring (B and G) 3 26 08395 Manifold (A, H, J & K) 1 26 06255 Manifold (B and G) 1 27A 08408 Valve Assembly (A, B, G, H) 6 27A 08408-0001 Valve Assembly (J & K) 6 27 08370 Valve Seat 6 28 06791-0100 Valve Plate 6 29 06377-0100 Valve Spring 6 30 08372 Valve Spring Retainer 6 31 07212 O-Ring (A, B, G, H) 6 31 07212-0001 O-Ring, Viton (J & K) 6 32 08373 Plug 6 33 07214 O-Ring (A, B, G, H) 6 33 07214-0001 O-Ring, Viton (J & K) 6 34 08396 Cap Screw 8

P420/P420-0011/P420-0021/P422/P423 and P425 REPAIR KITS

Plunger Packing Kits P420, P425 - # 09140 Item Part # Description Qty 21 07266 O-Ring 3 22 08059 O-Ring 3 23 12254 V-Sleeve 3 23B 12255 Weep Seal 3 24 08376 Pressure Ring 6 P420-0011 - # 09140-0011 tem Part # Description Qty 21 07266-0001 O-Ring, Viton 3 22 08059-0001 O-Ring, Viton 3 23 12254-0010 V-Sleeve, Viton 3 23B 12255-0010 Weep Seal, Viton 3 24 08376 Pressure Ring 6 P420-0021 - # 09140-0021 tem Part # Description Qty 21 07266-0001 O-Ring, Viton 3 22 08059-0001 O-Ring, Viton 3 23 12254-0020 V-Sleeve, Teflon 3 23B 12255-0020 Weep Seal, Teflon 3 24 08376 Pressure Ring 6

Plunger Packing Kit P422, P423 # 09295 Item Part # Description Qty 21 07266 O-Ring 3 22 08059 O-Ring 3 23 06249 V-Sleeve with Support Ring 3 23B 13390 Weep Seal 3 24 06252 Pressure Ring 3 Valve Assembly Kits P420, P422, P423, P425 - # 09143 Item Part # Description Qty. 27A 08408 Valve Assembly, Complete 6 33 07214 O-Ring 6 P420, P422, P423, P425 - # 09143-0001 Item Part # Description Qty. 27A 08408-0001 Valve Assembly, Complete 6 33 07214-0001 O-Ring 6 Oil Seal Kit P400 Series - # 09306 Item Part # Description Qty 19 08366 Oil Seal 3

Page 8 of the Giant P423 user manual — Specifications
Page 8 · click to enlarge
Page 8

Specifications

Model P425

U.S. (Metric) Volume Up to 10.7 GPM (40.6 LPM) Discharge Pressure Up to 2465 PSI (170 bar) Inlet Pressure -4.35 to 145 PSI (-.3 to 10 bar) Stroke 0.787” (20mm) RPM Up to 1450 RPM Plunger Diameter 0.98” (25mm) Temperature of Pumped Fluids Up to 160 oF (71 oC) Inlet Ports (2) 1" NPT Discharge Ports (2) 3/4" NPT Shaft Rotation Top of pulley towards manifold Crankshaft Diameter 1.102” (28mm) Key Width 315” (8mm) Shaft Mounting Either side1

Weight 36 lbs. 11oz (16.64 kg) CrankcaseCapacity 27 fl.oz (0.8 liters) Volumetric Efficiency @ 1450 (0.95) Mechanical Efficiency @ 1450 (0.83)

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P425 HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI2000 PSI2465 PSI 7505.63.85.77.69.4 9006.74.66.99.111.3 10107.55.27.710.212.7 11208.35.78.611.414.1 12409.26.39.512.615.6 145010.77.411.114.718.2

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:

The theoretical gallons per revolution (gal/rev) is 0.0074. To find specific outputs at various RPM, use the formula: GPM = 0.0074 x RPM

Page 9 of the Giant P423 user manual — Model P425
Page 9 · click to enlarge
Page 9

Repair Instructions P420/P420-0011/P420-0021/P422/P423 and P425 Note: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.e., the elastomers) from cutting and scoring.

Giant P423 — Model P425 diagram (page 9)
Fig. 5 · Model P425
Giant P423 — Model P425 diagram (page 9)
Fig. 6 · Model P425
Giant P423 — Model P425 diagram (page 9)
Fig. 7 · Model P425
1. With a socket wrench, remove the three discharge valve plugs and three inlet valve plugs (32). Inspect the o-ring (33) for wear and replace if damaged.
2. Using needle nose pliers, remove the inlet and discharge valve assemblies (27A). Note: It may become neccesary to remove the valve seat (27) from the valve casing using a slidehammer.
3. By inserting a small screw driver between the valve seat (27) and the valve spring retainer (30), the valve assembly can be separated.
Giant P423 — Model P425 diagram (page 9)
Fig. 8 · Model P425
Giant P423 — Model P425 diagram (page 9)
Fig. 9 · Model P425
Giant P423 — Model P425 diagram (page 9)
Fig. 10 · Model P425
4. Remove the o-ring (31). Inspect all parts for wear and replace as necessary. Apply one drop of loctite 243 to the valve plugs (32) and tighten to 107 ft.-lbs. (145 NM).
5. Use a 8mm allen wrench to remove the 8 socket head cap screws (34). Carefully slide the valve casing (26) out over the plungers.
6. Remove seal adaptors (20) and weep return rings (25) from the valve casing.
Giant P423 — Model P425 diagram (page 9)
Fig. 11 · Model P425
Giant P423 — Model P425 diagram (page 9)
Fig. 12 · Model P425
7. Remove the pressure rings (24) and v-sleeves (23 - Note: P422 & P423 pumps have a support ring) from the valve casing (26).
8. Remove the weep grooved seal (23 or 23B) together with pressure ring (24 _ P420 and P425 only) out of the seal adaptor (20). Check O-rings (21).
Page 10 of the Giant P423 user manual — Contact Giant Industries for service school information. Phone: (419) 531-4600
Page 10 · click to enlarge
Page 10

Repair Instructions P420/P420-0011/P420-0021/P422/P423 and P425

Giant P423 — Repair Instructions P420/P420-0011/P420-0021/P422/P423 and P425 diagram (page 10)
Fig. 13 · Repair Instructions P420/P420-0011/P420-0021/P422/P4…
Giant P423 — Repair Instructions P420/P420-0011/P420-0021/P422/P423 and P425 diagram (page 10)
Fig. 14 · Repair Instructions P420/P420-0011/P420-0021/P422/P4…
9. Check surfaces of plunger (16). Damaged surfaces cause accelerated seal wear. Deposits of all kinds must be removed from the plungers.
10. If the plunger pipe (16B), or oil seal (19) is worn, remove tension screw (16D) and remove along with plunger pipe (16B). Check and clean plunger surface (16A), check oil scraper (16H). Remove the gear seal adapter (20A) and, if necessary, replace oil seals with seal lips facing crankcase (1).Cover thread of tension screw (16D) with a thin film of Loctite and tighten carefully to 22 ft.-lbs. (30NM).
11. After installation of high pressure seals (23), place seal adaptor (20) with weep seals & pressure ring installed, weep return ring (25) and high pressure weep return ring (24) over plungers. Slide valve casing over plungers and seat firmly. Replace the 8 socket head cap screws (34) and tighten to 30 ft.-lbs.(47 NM) in a crossing pattern (as shown below).
Giant P423 — Repair Instructions P420/P420-0011/P420-0021/P422/P423 and P425 diagram (page 10)
Fig. 15 · Repair Instructions P420/P420-0011/P420-0021/P422/P4…

Torque Specifications P420/P420-0011/P420-0021/P422/P423 and P425

Position Item# Description U.S Metric 15A 07311 Screw with Washer 97 in.-lbs. 11 NM 16D 08399 Tensioning Screw 22 ft.-lbs. 30 NM 32 08373 Plug (P420, P422, P423, P425) 107 ft.-lbs. 145 NM 34 08396/08484 Cap Screw 30 ft.-lbs. 40 NM

Contact Giant Industries for service school information. Phone: (419) 531-4600

Page 11 of the Giant P423 user manual — Preventative Maintenance Check-List & Recommended Spare Parts List
Page 11 · click to enlarge
Page 11

PUMP SYSTEM MALFUNCTION

MALFUNCTION CAUSE REMEDY

The Pressure and/ Worn packing seals Replace packing seals or the Delivery Broken valve spring Replace spring Drops Belt slippage Tighten or Replace belt Worn or Damaged nozzle Replace nozzle Fouled discharge valve Clean valve assembly Fouled inlet strainer Clean strainer Worn or Damaged hose Repair/Replace hose Worn or Plugged relief valve on pump Clean, Reset, and Replace worn parts Cavitation Check suction lines on inlet of pump for restrictions Unloader Check for proper operation

Water in crankcase High humidity Reduce oil change interval Worn seals Replace seals

Noisy Operation Worn bearings Replace bearings, Refill crankcase oil with recommended lubricant Cavitation Check inlet lines for restrictions and/or proper sizing

Rough/Pulsating Worn packing Replace packing Operation with Inlet restriction Check system for stoppage, air Pressure Drop leaks, correctly sized inlet plumbing to pump Accumulator pressure Recharge/Replace accumulator Unloader Check for proper operation Cavitation Check inlet lines for restrictions and/or proper size

Pump Pressure as Restricted discharge plumbing Re-size discharge plumbing to Flow Rated, Pressure Rate of Pump Drop at Gun

Excessive Worn plungers Replace plungers Leakage Worn packing/seals Adjust or Replace packing seals Excessive vacuum Reduce suction vacuum Cracked plungers Replace plungers Inlet pressure too high Reduce inlet pressure

High Crankcase Wrong Grade of oil Giant oil is recommended Temperature Improper amount of oil in crankcase Adjust oil level to proper amount

Preventative Maintenance Check-List & Recommended Spare Parts List

Check Daily Weekly 50hrs Every Every Every 500 hrs 1500 hrs 3000 hrs

Oil Level/Quality X Oil Leaks X Water Leaks X Belts, Pulley X Plumbing X Recommended Spare Parts Oil Change (1 Gallon) p/n 1154 X X Seal Spare Parts (1 kit/pump) X (See page 7 for kit list) Oil Seal Kit (1 kit/pump) X (See page 7 for kit lit) Valve Spare Parts (1 kit/pump) X (See page 7 for kit list)

Page 12 of the Giant P423 user manual — GIANT INDUSTRIES LIMITED WARRANTY
Page 12 · click to enlarge
Page 12

Dimensions - P420/P420-0011/P420-0021/P422/P423 and P425 - Inches (mm)

Giant P423 — Dimensions - P420/P420-0011/P420-0021/P422/P423 and P425 - Inches (mm) diagram (page 12)
Fig. 16 · Dimensions - P420/P420-0011/P420-0021/P422/P423 and…
Giant P423 — Dimensions - P420/P420-0011/P420-0021/P422/P423 and P425 - Inches (mm) diagram (page 12)
Fig. 17 · Dimensions - P420/P420-0011/P420-0021/P422/P423 and…

GIANT INDUSTRIES LIMITED WARRANTY

Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows:

1. For portable pressure washers and self-service car wash applications, the discharge manifolds will never fail, period. If they ever fail, we will replace them free of charge. Our other pump parts, used in portable pressure washers and in car wash applications, are warranted for five years from the date of shipment for all pumps used in NON- SALINE, clean water applications. 2. One (1) year from the date of shipment for all other Giant industrial and consumer pumps. 3. Six (6) months from the date of shipment for all rebuilt pumps. 4. Ninety (90) days from the date of shipment for all Giant accessories.

This warranty is limited to repair or replacement of pumps and accessories of which the manufacturer’s evaluation shows were defective at the time of shipment by the manufacturer. The following items are NOT covered or will void the warranty:

1. Defects caused by negligence or fault of the buyer or third party. 2. Normal wear and tear to standard wear parts. 3. Use of repair parts other than those manufactured or authorized by Giant. 4. Improper use of the product as a component part. 5. Changes or modifications made by the customer or third party. 6. The operation of pumps and or accessories exceeding the specifications set forth in the Operations Manuals provided by Giant Industries, Inc.

Liability under this warranty is on all non-wear parts and limited to the replacement or repair of those products returned freight prepaid to Giant Industries which are deemed to be defective due to workmanship or failure of material. A Returned Goods Authorization (R.G.A.) number and completed warranty evaluation form is required prior to the return to Giant Industries of all products under warranty consideration. Call (419)-531-4600 or fax (419)-531-6836 to obtain an R.G.A. number.

Repair or replacement of defective products as provided is the sole and exclusive remedy provided hereunder and the MANUFACTURER SHALL NOT BE LIABLE FOR FURTHER LOSS, DAMAGES, OR EXPENSES, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES DIRECTLY OR INDIRECTLY ARISING FROM THE SALE OR USE OF THIS PRODUCT.

THE LIMITED WARRANTY SET FORTH HEREIN IS IN LIEU OF ALL OTHER WARRANTIES OR REPRESEN- TATION, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OR MERCHANT- ABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ALL SUCH WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED BY THE MANUFACTURER.

GIANT INDUSTRIES, INC., 900 N. Westwood Ave., P.O. Box 3187, Toledo, Ohio 43607 PHONE (419) 531-4600, FAX (419) 531-6836, www.giantpumps.com Copyright 2007 Giant Industries, Inc.

11/07 P400-22_25mm.PMD

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Giant P423

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Giant P423

Be the first to ask — other owners or our team will answer.

Original document

Giant P423 manual PDF

12 pages·191 KB·Septic System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…