Table of Contents 17 sections Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual · Series P200 -12mm versions · Updated 7/07 · INSTALLATION INSTRUCTIONS · … ShowHide
Page 1 of the Giant P209 user manual — Updated 7/07
Page 1 · click to enlarge
Page 1

Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Series P200 -12mm versions

Giant P209 — Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual diagram (page 1)
Fig. 1 · Triplex Ceramic Plunger Pump Operating Instructions/…
Giant P209 — Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual diagram (page 1)
Fig. 2 · Triplex Ceramic Plunger Pump Operating Instructions/…

Contents: Installation Instructions: page 2 Pump Specifications: pages 3-9 Exploded View: page 10 Parts List: page 11 Kits & Torque Specifications:page 12 Pump Mounting Selection Guide: page 12 Repair Instructions: pages 13-14 Recommended Spare Parts List: page 14 Dimensions: page 15 Warranty Information: back page

Updated 7/07

Page 2 of the Giant P209 user manual — Use Giant 20W-50 oil (p/n 01153)
Page 2 · click to enlarge
Page 2

INSTALLATION INSTRUCTIONS

Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installa- tion. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance.

4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsation. Dampeners can also reduce the severity of pressure spikes that occur in systems using a shut-off gun. A dampener must be positioned downstream from the unloader.
1. The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication.
5. Crankshaft rotation on Giant Industries, Inc. pumps should be made in the direction designated by the arrows on the pump crankcase. Reverse rotation may be safely achieved by following a few guidelines available upon request from Giant Industries, Inc. Required horsepower for system operation can be obtained from the charts on pages 3-9.
2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joints. If pumps are to be operated at temperatures in excess of 160 0 F, it is important to insure a positive head to the pump to prevent cavitation.
6. Before beginning operation of your pumping system, remember: Check that the crankcase and seal areas have been properly lubricated per recommended schedules. Do not run the pump dry for extended periods of time. Cavitation will result in severe damage. Always remember to check that all plumbing valves are open and that pumped media can flow freely to the inlet of the pump.
3. The discharge plumbing from the pump should be properly sized to the flow rate to prevent line pressure loss to the work area. It is essential to provide a safety bypass valve between the pump and the work area to protect the pump from pressure spikes in the event of a blockage or the use of a shut-off gun.

Finally, remember that high pressure operation in a pump system has many advantages. But, if it is used carelessly and without regard to its potential hazard, it can cause serious injury.

IMPORTANT OPERATING CONDITIONS

Failure to comply with any of these conditions invalidates the warranty.

1. Prior to initial operation, add oil to the crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL.
2. Pump operation must not exceed rated pressure, volume, or RPM. A pressure relief device must be installed in the discharge of the system.

Use Giant 20W-50 oil (p/n 01153)

3. Acids, alkalines, or abrasive fluids cannot be pumped unless approval in writing is obtained before operation from Giant Industries, Inc.

Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.

4. Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures.
Page 3 of the Giant P209 user manual — INSTALLATION INSTRUCTIONS
Page 3 · click to enlarge
Page 3

1750 RPM+ U. .S. Metric Flow (Continuous) @ 2000 PSI (140 Bar) 0.5 GPM 1.9 L/min Flow (Intermittent) @ 2500 PSI (175 Bar) 0.5 GPM 1.9 L/min 3450 RPM+ Flow (Continuous) @ 2000 PSI (140 Bar) 0.9 GPM 2.4 L/min Flow (Intermittent) @ 2000 PSI (140 Bar) 0.9 GPM 2.4 L/min Maximum Inlet Pressure 145 PSI 10 Bar Plunger Diameter 0.47” 12 mm Stroke 0.13” 3.4 mm Max. Temperature of Pumped Fluids 160

o C Inlet Ports (2) 1/2" BSP Discharge Ports (2) 3/8" BSP Shaft Rotation Top of Pulley Towards Fluid End Crankshaft Diameter 0.98” 24 mm Key Width 0.31” 8 mm Shaft Mounting Right Side Facing Manifold Weight 11.7 lbs 5.3 Kg Crankcase Oil Capacity 7.5 fl.oz 0.22 Liters Extended Crankcase Oil Capacity 9.0 fl.oz 0.27 Liters Volumetric Efficiency @ 1750 RPM 0.94 Volumetric Efficiency @ 3450 RPM 0.87 Mechanical Efficiency @ 3450 RPM 0.86

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P205 HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI2000 PSI2500 PSI* 5000.130.10.10.20.2 10000.290.20.30.40.5 17500.500.30.50.70.9 30000.780.50.81.11.4 32000.840.60.91.21.4 34500.900.60.91.21.6

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electricmotor as the power source. To compute specific pump horse power requirements, use the following formula:

*intermittent duty

Page 4 of the Giant P209 user manual — INSTALLATION INSTRUCTIONS
Page 4 · click to enlarge
Page 4

1750 RPM+ U. .S. Metric Flow (Continuous) @ 2000 PSI (140 Bar) 0.8 GPM 3.0 L/min Flow (Intermittent) @ 2500 PSI (175 Bar) 0.8 GPM 3.0 L/min 3450 RPM+ Flow (Continuous) @ 2000 PSI (140 Bar) 1.5 GPM 5.7 L/min Flow (Intermittent) @ 2000 PSI (140 Bar) 1.5 GPM 5.7 L/min Maximum Inlet Pressurez 145 PSI 10 Bar Plunger Diameter 0.47” 12 mm Stroke 0.22” 5.5 mm Max. Temperature of Pumped Fluids 160

o C Inlet Ports (2) 1/2" BSP Discharge Ports (2) 3/8" BSP Shaft Rotation Top of Pulley Towards Fluid End Crankshaft Diameter 0.98” 24 mm Key Width 0.31” 8 mm Shaft Mounting Right Side Facing Manifold Weight 11.7 lbs 5.3 Kg Crankcase Oil Capacity 7.5 fl.oz 0.22 Liters Extended Crankcase Oil Capacity 9.0 fl.oz 0.27 Liters Volumetric Efficiency @ 1750 RPM 0.94 Volumetric Efficiency @ 3450 RPM 0.87 Mechanical Efficiency @ 3450 RPM 0.86

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

P206 HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI2000 PSI2500 PSI* 2500.110.10.10.20.2 5000.210.10.20.30.4 10000.430.30.40.60.7 17500.760.50.81.01.3 30001.300.91.31.82.2 32001.401.01.41.92.4 34501.501.01.62.12.6

be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:

Page 5 of the Giant P209 user manual — INSTALLATION INSTRUCTIONS
Page 5 · click to enlarge
Page 5

1750 RPM+ U. .S. Metric Flow (Continuous) @ 2000 PSI (140 Bar) 0.9 GPM 3.4 L/min Flow (Intermittent) @ 2500 PSI (175 Bar) 0.9 GPM 3.4 L/min 3450 RPM+ Flow (Continuous) @ 2000 PSI (140 Bar) 1.7 GPM 6.4 L/min Flow (Intermittent) @ 2000 PSI (140 Bar) 1.7 GPM 6.4 L/min Maximum Inlet Pressure 145 PSI 10 Bar Plunger Diameter 0.47” 12 mm Stroke 0.25” 6.3 mm Max. Temperature of Pumped Fluids 160

o C Inlet Ports (2) 1/2" BSP Discharge Ports (2) 3/8" BSP Shaft Rotation Top of Pulley Towards Fluid End Crankshaft Diameter 0.98” 24 mm Key Width 0.31” 8 mm Shaft Mounting Right Side Facing Manifold Weight 11.7 lbs 5.3 Kg Crankcase Oil Capacity 7.5 fl.oz 0.22 Liters Extended Crankcase Oil Capacity 9.0 fl.oz 0.27 Liters Volumetric Efficiency @ 1750 RPM 0.94 Volumetric Efficiency @ 3450 RPM 0.87 Mechanical Efficiency @ 3450 RPM 0.86

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

P207 HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI2000 PSI2500 PSI* 5000.260.20.30.40.4 10000.510.40.50.70.9 17500.900.60.91.21.6 30001.481.01.52.02.6 32001.581.11.62.22.7 34501.701.21.82.32.9

be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:

Page 6 of the Giant P209 user manual — INSTALLATION INSTRUCTIONS
Page 6 · click to enlarge
Page 6

1750 RPM+ U. .S. Metric Flow (Continuous) @ 2000 PSI (140 Bar) 1.0 GPM 3.8 L/min Flow (Intermittent) @ 2500 PSI (175 Bar) 1.0 GPM 3.8 L/min 3450 RPM+ Flow (Continuous) @ 2000 PSI (140 Bar) 1.9 GPM 7.2 L/min Flow (Intermittent) @ 2000 PSI (140 Bar) 1.9 GPM 7.2 L/min Maximum Inlet Pressure 145 PSI 10 Bar Plunger Diameter 0.47” 12 mm Stroke 0.28” 7 mm Max. Temperature of Pumped Fluids 160

o C Inlet Ports (2) 1/2" BSP Discharge Ports (2) 3/8" BSP Shaft Rotation Top of Pulley Towards Fluid End Crankshaft Diameter 0.98” 24 mm Key Width 0.31” 8 mm Shaft Mounting Right Side Facing Manifold Weight 11.7 lbs 5.3 Kg Crankcase Oil Capacity 7.5 fl.oz 0.22 Liters Extended Crankcase Oil Capacity 9.0 fl.oz 0.27 Liters Volumetric Efficiency @ 1750 RPM 0.94 Volumetric Efficiency @ 3450 RPM 0.87 Mechanical Efficiency @ 3450 RPM 0.86

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P208 HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI2000 PSI2500 PSI* 2500.140.10.10.20.2 5000.290.20.30.40.5 10000.570.40.60.81.0 17501.000.71.01.41.7 30001.601.11.72.22.8 32001.801.21.92.53.1 34501.901.32.02.63.3

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:

Page 7 of the Giant P209 user manual — INSTALLATION INSTRUCTIONS
Page 7 · click to enlarge
Page 7

1750 RPM+ U. .S. Metric Flow (Continuous) @ 2000 PSI (140 Bar) 1.5 GPM 5.7 L/min Flow (Intermittent) @ 2500 PSI (175 Bar) 1.5 GPM 5.7 L/min 3450 RPM+ Flow (Continuous) @ 2000 PSI (140 Bar) 2.7 GPM 10.2 L/min Flow (Intermittent) @ 2000 PSI (140 Bar) 2.7 GPM 10.2 L/min Maximum Inlet Pressure 145 PSI 10 Bar Plunger Diameter 0.47” 12 mm Stroke 0.39” 10 mm Max. Temperature of Pumped Fluids 160

o C Inlet Ports (2) 1/2" BSP Discharge Ports (2) 3/8" BSP Shaft Rotation Top of Pulley Towards Fluid End Crankshaft Diameter 0.98” 24 mm Key Width 0.31” 8 mm Shaft Mounting Right Side Facing Manifold Weight 11.7 lbs 5.3 Kg Crankcase Oil Capacity 7.5 fl.oz 0.22 Liters Extended Crankcase Oil Capacity 9.0 fl.oz 0.27 Liters Volumetric Efficiency @ 1750 RPM 0.94 Volumetric Efficiency @ 3450 RPM 0.87 Mechanical Efficiency @ 3450 RPM 0.86

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P209 HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI2000 PSI2500 PSI* 5000.430.30.40.60.7 10000.860.60.91.21.5 17501.501.01.62.12.6 30002.351.62.43.24.0 32002.501.72.63.44.3 34502.701.92.83.74.7

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electricmotor as the power source. To compute specific pump horse power requirements, use the following formula:

Page 8 of the Giant P209 user manual — INSTALLATION INSTRUCTIONS
Page 8 · click to enlarge
Page 8

1750 RPM+ U. .S. Metric Flow (Continuous) @ 2000 PSI (140 Bar) 1.8 GPM 6.8 L/min Flow (Intermittent) @ 2500 PSI (175 Bar) 1.8 GPM 6.8 L/min 3450 RPM+ Flow (Continuous) @ 2000 PSI (140 Bar) 3.3 GPM 12.5 L/min Flow (Intermittent) @ 2000 PSI (140 Bar) 3.3 GPM 12.5 L/min Maximum Inlet Pressure 145 PSI 10 Bar Plunger Diameter 0.47” 12 mm Stroke 0.49” 12.4 mm Max. Temperature of Pumped Fluids 160

o C Inlet Ports (2) 1/2" BSP Discharge Ports (2) 3/8" BSP Shaft Rotation Top of Pulley Towards Fluid End Crankshaft Diameter 0.98” 24 mm Key Width 0.31” 8 mm Shaft Mounting Right Side Facing Manifold Weight 11.7 lbs 5.3 Kg Crankcase Oil Capacity 7.5 fl.oz 0.22 Liters Extended Crankcase Oil Capacity 9.0 fl.oz 0.27 Liters Volumetric Efficiency @ 1750 RPM 0.94 Volumetric Efficiency @ 3450 RPM 0.87 Mechanical Efficiency @ 3450 RPM 0.86

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P210 HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI2000 PSI2500 PSI* 2500.260.20.30.40.4 5000.510.40.50.70.9 10001.030.71.11.41.8 17501.801.21.92.53.1 30002.872.03.04.05.0 32003.062.13.24.25.3 34503.302.33.44.65.7

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:

Page 9 of the Giant P209 user manual — INSTALLATION INSTRUCTIONS
Page 9 · click to enlarge
Page 9

1750 RPM+ U. .S. Metric Flow (Continuous) @ 2000 PSI (140 Bar) 2.1 GPM 7.9 L/min Flow (Intermittent) @ 2500 PSI (175 Bar) 2.1 GPM 7.9 L/min 3450 RPM+ Flow (Continuous) @ 2000 PSI (140 Bar) 3.8 GPM 14.4 L/min Flow (Intermittent) @ 2000 PSI (140 Bar) 3.8 GPM 14.4 L/min Maximum Inlet Pressure 145 PSI 10 Bar Plunger Diameter 0.47” 12 mm Stroke 0.56” 14.2 mm Max. Temperature of Pumped Fluids 160

o C Inlet Ports (2) 1/2" BSP Discharge Ports (2) 3/8" BSP Shaft Rotation Top of Pulley Towards Fluid End Crankshaft Diameter 0.98” 24 mm Key Width 0.31” 8 mm Shaft Mounting Right Side Facing Manifold Weight 11.7 lbs 5.3 Kg Crankcase Oil Capacity 7.5 fl.oz 0.22 Liters Extended Crankcase Oil Capacity 9.0 fl.oz 0.27 Liters Volumetric Efficiency @ 1750 RPM 0.94 Volumetric Efficiency @ 3450 RPM 0.87 Mechanical Efficiency @ 3450 RPM 0.86

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P211 HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI2000 PSI2500 PSI* 5000.600.40.60.81.0 10001.200.81.21.72.1 17502.101.42.22.93.6 30003.302.33.44.65.7 32003.522.43.64.96.1 34503.802.63.95.26.5

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electricmotor as the power source. To compute specific pump horse power requirements, use the following formula:

Page 10 of the Giant P209 user manual — Exploded View - P205/P206/P207/P208/P209/P210/P211
Page 10 · click to enlarge
Page 10

Exploded View - P205/P206/P207/P208/P209/P210/P211

Giant P209 — Exploded View - P205/P206/P207/P208/P209/P210/P211 diagram (page 10)
Fig. 3 · Exploded View - P205/P206/P207/P208/P209/P210/P211
Page 11 of the Giant P209 user manual — P205/P206/P207/P208/P209/P210/P211 PARTS LIST
Page 11 · click to enlarge
Page 11

P205/P206/P207/P208/P209/P210/P211 PARTS LIST

ITEM PART NO. DESCRIPTION QTY.

ITEM PART NO. DESCRIPTION QTY.

1 08300 Crankcase 1

14 06207 Woodruff Key 1

2 06773 Oil Dipstick with O-Ring 1

15 08333 Connecting Rod 3

3 08302 Crankcase Cover, Short 1

16 06641 Plunger, Complete, 12mm 3

3 08302-L Crankcase Cover, Long 1

17 08442 Wrist Pin 3

3A 07190 Drain Plug 1

19 08356-0010 Oil Seal 3

3B 13262 Gasket for drain plug 1

20 06645 Seal Case 3

4 08005 O-Ring 1

21 08443 O-Ring 3

5 06273 Oil Drain Plug with Gasket 1

23 07391 V-Sleeve 3

5A 08192 Gasket 1

23A 08598 V-Sleeve, Weep 3

6 07188 Screw, Short Cover 4

24 07392 Support Ring 3

6A 01176-2 Spring Washer 12

25 06646 Weep Return Ring 3

7 08303 Bearing Cover I 2

26 06647 Valve Casing 1

8 08490 Sight Glass 1

27 07849 Valve Seat 6

9 08492 O-Ring for Sight Glass 1

28 07491 Valve Plate 6

10 07225 Screw with Lock Washer 8

29 07906 Valve Spring 6

11 01166 Radial Shaft Seal 1

30 07907 Valve Spring Retainer 6

12A 08020 Ball Bearing 1

31 07853 O-Ring 6

12B 01020 Ball Bearing 1

32 07928 Valve Plug 6

13 06694 Crankshaft (P205) 1

32X 07946 Valve Assembly Complete 6

13 08465 Crankshaft (P206) 1

33 07913 O-Ring 6

13 06547 Crankshaft (P207) 1

34 08316 Hex Head Cap Screw 8

13 12258 Crankshaft (P208) 1

38 13338 Plug, 3/8" BSP 1

13 08440 Crankshaft (P209) 1

38A 07661 Seal 1

13 08466 Crankshaft (P210) 1

39 07109 Plug, 1/2" BSP 1

13 08467 Crankshaft (211) 1

39A 08486 Copper Seal Ring 1

Page 12 of the Giant P209 user manual — Pump Mounting Selection Guide
Page 12 · click to enlarge
Page 12

P205/P206/P207/P208/P209/P210/P211 REPAIR KITS

Plunger Packing Kit Part # 09527 Item # Part # Description Qty. 23 07391 V-Sleeve, weep 3 23A 08598 V-Sleeve 3 24 07392 Support Ring 3

Oil Seal Kit Part # 09144 Item # Part # Description Qty. 19 08356-0010 Oil Seal 3

Valve Assembly Kit Part # 09116 Item # Part # Description Qty. 32X 07946 Valve Assembly Complete 6 31 07853 O-Ring 6

P205/P206/P207/P208/P210/P211 TORQUE SPECIFICATIONS

Position Item# Description Torque Amount 32 07928 Valve Plug 59 (ft.-lbs.) 34 08316 Hex Head Cap Screw, Valve Casing 105 (in.-lbs.)

Pump Mounting Selection Guide

Bushings 01074 - 24 mm Tapered H Bushing

Pulley & Sheaves 01061 - 7.75” Cast Iron 1 gr. - AB Section 01062 - 7.75” Cast Iron - 2 gr. - AB Section

Rails 01160 - Plated Steel Channel Rails (L=5.75”x W=1.00”x h=2.50”) 01161 - Plated Steel Channel Rails (L=5.75”x W=1.00”x H=2.50”)

Page 13 of the Giant P209 user manual — REPAIR INSTRUCTIONS - P205/P206/P207/P208/P209/P210/P211 PUMPS
Page 13 · click to enlarge
Page 13

REPAIR INSTRUCTIONS - P205/P206/P207/P208/P209/P210/P211 PUMPS

Giant P209 — REPAIR INSTRUCTIONS - P205/P206/P207/P208/P209/P210/P211 PUMPS diagram (page 13)
Fig. 4
Giant P209 — REPAIR INSTRUCTIONS - P205/P206/P207/P208/P209/P210/P211 PUMPS diagram (page 13)
Fig. 5
Giant P209 — REPAIR INSTRUCTIONS - P205/P206/P207/P208/P209/P210/P211 PUMPS diagram (page 13)
Fig. 6
1. With a 22mm socket wrench, remove the (3) discharge valve plugs and (3) inlet valve plugs (32) Inspect the o-ring (33) for wear and replace if damaged.
2. Using a needle nose pliers, remove the inlet and discharge valve assemblies (32X).
3. By inserting a small screw driver between the valve seat (27) and the valve spring retainer (30), the valve assembly can be separated.
Giant P209 — REPAIR INSTRUCTIONS - P205/P206/P207/P208/P209/P210/P211 PUMPS diagram (page 13)
Fig. 7
Giant P209 — REPAIR INSTRUCTIONS - P205/P206/P207/P208/P209/P210/P211 PUMPS diagram (page 13)
Fig. 8
Giant P209 — REPAIR INSTRUCTIONS - P205/P206/P207/P208/P209/P210/P211 PUMPS diagram (page 13)
Fig. 9
4. Remove the o-ring (31). Inspect all parts for wear and replace as necessary. For pumps manufactured prior to 5/97, tighten plugs (32) to 33 ft-lbs. otherwise, apply one drop of Loctite 243 to the valve plugs (32) and tighten to 59 ft.-lbs.
5. Next, use a 5mm allen wrench to remove the 8 socket head cap screws (34).
6. Carefully slide the valve casing (26) out over the plungers.
9. If the crankcase oil seals (19) are to be replaced, they can be removed by first removing the crankshaft (13), connecting rod (15), and plunger assembly (16) from the gear end. Then the oil seals can be pushed out from the rear. Please contact Giant for details.
Giant P209 — REPAIR INSTRUCTIONS - P205/P206/P207/P208/P209/P210/P211 PUMPS diagram (page 13)
Fig. 10
8. Check surfaces of plunger (16). A damaged surface will cause accelerated wear on the seals. Deposits of any kind must be carefully removed from the plunger surface. A damaged plunger must be replaced!
7. Remove the weep return ring (25), pressure ring (24), and v-sleeve (23) from the valve casing (26). Remove the weep v-sleeve (23A) from the seal case (20).Inspect all parts, including o-ring (21) for wear and replace as necessary.
Page 14 of the Giant P209 user manual — NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600
Page 14 · click to enlarge
Page 14

REPAIR INSTRUCTIONS - P205/P206/P207/P208/P209/P210/P211 PUMPS

10. If the ceramic plunger pipe (16) is damaged, replace entire plunger assembly by removing crankshaft (13). Contact Giant for further details.

Reassembly sequence of the P205/P206/P207/P208/P209/P210/P211 PUMPS

1. If oil seals (19) were removed, replace with seal lip towards crankcase. Lubricate seals before replacing. Contact Giant for assistance with the reassembly of the gear end.
2. Replace seal case (20) with o-rings (21) over plungers. Generously lubricate o-rings and oil seal before reassembly. Replace weep v-sleeve (23A) over plungers (16)..
3. Generously lubricate v-sleeve (23). Assemble v-sleeves (23) into valve casing (#26). Assemble weep return ring (25) and pressure ring (24) over plungers (16). Slide valve casing over plungers and seat firmly. Replace the eight socket head cap screws (34) and tighten to 105 inch-pounds in a crossing pattern.
4. Replace the six o-rings (31) and the six valve assemblies (32X). Now replace the six valve plug o-rings (33). Apply one drop of Loctite 243 to the valve plugs (32) and tighten to 59 ft.-lbs.

For maintenance of the gear end of your pump contact Giant Industries or your local distributor. Phone: 419/531-4600

NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600

Preventative Maintenance Check-List & Recommended Spare Parts List

Check Daily Weekly 50hrs Every Every Every 500 hrs 1500 hrs 3000 hrs

Oil Level/Quality X Oil Leaks X Water Leaks X Belts, Pulley X Plumbing X Recommended Spare Parts Oil Change (1 Gallon) p/n 1154 X X Seal Spare Parts (1 kit/pump) X (See page 12 for kit list) Oil Seal Kit (1 kit/pump) X (See page 12 for kit lit) Valve Spare Parts (1 kit/pump) X (See page 12 for kit list)

Page 15 of the Giant P209 user manual — P205/P206/P207/P208/P209/P210/P211 DIMENSIONS - Inches (mm)
Page 15 · click to enlarge
Page 15

P205/P206/P207/P208/P209/P210/P211 DIMENSIONS - Inches (mm)

Giant P209 — P205/P206/P207/P208/P209/P210/P211 DIMENSIONS - Inches (mm) diagram (page 15)
Fig. 11 · P205/P206/P207/P208/P209/P210/P211 DIMENSIONS - Inch…
Giant P209 — P205/P206/P207/P208/P209/P210/P211 DIMENSIONS - Inches (mm) diagram (page 15)
Fig. 12 · P205/P206/P207/P208/P209/P210/P211 DIMENSIONS - Inch…
Page 16 of the Giant P209 user manual — GIANT INDUSTRIES LIMITED WARRANTY
Page 16 · click to enlarge
Page 16

GIANT INDUSTRIES LIMITED WARRANTY

Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from

defects in workmanship and material as follows:

1. For portable pressure washers and self-serve car wash applications, the discharge

manifolds will never fail, period. If they ever fail, we will replace them free of charge.

Our other pump parts, used in portable pressure washers and in car wash applica-

tions, are warranted for five years from the date of shipment for all pumps used in NON-

SALINE, clean water applications.

2. One (1) year from the date of shipment for all other Giant industrial and consumer

pumps.

3. Six (6) months from the date of shipment for all rebuilt pumps.
4. Ninety (90) days from the date of shipment for all Giant accessories.

This warranty is limited to repair or replacement of pumps and accessories of which the manufacturer’s

evaluation shows were defective at the time of shipment by the manufacturer. The following items

are NOT covered or will void the warranty:

1. Defects caused by negligence or fault of the buyer or third party.
2. Normal wear and tear to standard wear parts.
3. Use of repair parts other than those manufactured or authorized by Giant.
4. Improper use of the product as a component part.
5. Changes or modifications made by the customer or third party.
6. The operation of pumps and or accessories exceeding the specifications set forth

in the Operations Manuals provided by Giant Industries, Inc.

Liability under this warranty is on all non-wear parts and limited to the replacement or repair of those

products returned freight prepaid to Giant Industries which are deemed to be defective due to

workmanship or failure of material. A Returned Goods Authorization (R.G.A.) number and completed

warranty evaluation form is required prior to the return to Giant Industries of all products under

warranty consideration. Call (419)-531-4600 or fax (419)-531-6836 to obtain an R.G.A. number.

Repair or replacement of defective products as provided is the sole and exclusive remedy provided

hereunder and the MANUFACTURER SHALL NOT BE LIABLE FOR FURTHER LOSS, DAMAGES,

OR EXPENSES, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES DIRECTLY OR

INDIRECTLY ARISING FROM THE SALE OR USE OF THIS PRODUCT.

THE LIMITED WARRANTY SET FORTH HEREIN IS IN LIEU OF ALL OTHER WARRANTIES OR

REPRESENTATION, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WAR-

RANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ALL SUCH

WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED BY THE MANUFACTURER.

GIANT INDUSTRIES, INC., 900 N. Westwood Ave., P.O. Box 3187, Toledo, Ohio 43607 PHONE (419) 531-4600, FAX (419) 531-6836, www.giantpumps.com Copyright 2007 Giant Industries, Inc.

07/07 P200_12mm.PM6

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Giant P209

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Giant P209

Be the first to ask — other owners or our team will answer.

Original document

Giant P209 manual PDF

16 pages·225 KB·Heat Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…