Instruction/ maintenance manual of the product P200A-5100 Giant
Go to page of 16
Contents: Installation Instructions: page 2 Pump Specifications: pages 3-9 Exploded View: page 1 0 Parts List / Kits: page 1 1 Torque Specifications: page 1 1 Repair Instructions: pages 12-13 Pump mou.
2 INST ALLA TION INSTR UCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 Specifications Model P217A-3100/5100 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. U.S. (Metric) 1750 RPM + Ratings .........................................
4 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. Specifications Model P218A-3100/5100 U.S. (Metric) V olume ....................................................
5 Specifications Model P219A-3100/5100 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. PUMP PULLEY MOTO R PULLEY RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI 7.
6 Specifications Model P220A-3100/5100 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. PUMP PULLEY MOTO R PULLEY RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI 7.
7 NOTE: In order to drive the pump fr om the side opposite the pr esent shaft extension, simply remov e the valve casing fr om the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are do wn a t the six o'c loc k position.
8 NOTE: In order to drive the pump fr om the side opposite the present shaft extension, simply remo ve the valve casing fr om the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to r otate the seal case (item #20) as well, so that the weep holes are do wn a t the six o'c loc k position.
9 NOTE: In order to drive the pump fr om the side opposite the present shaft extension, simply remov e the valve casing fr om the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to r ota te the seal case (item #20) as well, so that the weep holes are do wn a t the six o'c loc k position.
10 Exploded V iew - P200A-3100/5100 Series.
11 ITEM PART NO. DESCRIPTION QTY. 1 08300 Crankcase 1 2 08301 Dipstick 1 3 08302 Crankcase Plug Cover 1 3A 07190-0100 D rain Plug & Gasket 1 4 08005 O-Ring 1 5 08185-0100 Oil Drain Plug with seal 1 6 07188-0100 Screw, 316 S.S. 4 6A 07223-0100 Spring Washer, 316 S.
12 REP AIR INSTRUCTION - P200A-3100/5100 SERIES 1. W ith a 22mm socket wrench, remove the (3) discharge valve plugs and (3) inlet valve plugs (32) Inspect the o-ring (33) for wear and replace if dam- aged. 2. Using a needle nose pliers, remove the inlet and discharge valve assemblies (27-30) and o-ring (31).
13 Disassembly sequence of the back end of the P200A-3100/5100 series pump. 1) Before you begin, drain the oil from the crankcase. 2) Remove the crankcase cover (3) and o-ring (4) from the crankcase (1). T o remove the crankshaft (13), remove the bearing cover (7) and sight glass (8).
14 Preventative Maintenance Check-List & Recommended Spar e Parts List Check Daily W eekly 50hrs Every Every Every 500 hrs 1500 hrs 3000 hrs Oil Level/Quality X Oil Leaks X W ater Leaks X Belts, P.
15 P200A-3100/5100 DIMENSIONS - INCHES (mm).
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and car wash applications, the discharge manifolds will never fail, period.
An important point after buying a device Giant P200A-5100 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Giant P200A-5100 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Giant P200A-5100 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Giant P200A-5100 you will learn all the available features of the product, as well as information on its operation. The information that you get Giant P200A-5100 will certainly help you make a decision on the purchase.
If you already are a holder of Giant P200A-5100, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Giant P200A-5100.
However, one of the most important roles played by the user manual is to help in solving problems with Giant P200A-5100. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Giant P200A-5100 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center