Instruction/ maintenance manual of the product P200A-3100/5100 Giant
Go to page of 12
Contents: Installation Instructions: page 2 Pump Specifications: pages 3-7 Parts List / Kits: page 8 Torque Specifications: page 8 Exploded View: page 9 Repair Instructions: page 10-11 Warranty Inform.
INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
P217A-3100/5100 HORSEPOWER REQUIREMENTS RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI 1725 1.7 0.9 1.4 1.7 2.0 2.3 3000 3.0 1.7 2.5 3.1 3.5 4.1 3200 3.
P218A-3100/5100 HORSEPOWER REQUIREMENTS RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI 1150 2.1 1.2 1.7 2.2 2.5 2.9 1450 2.6 1.5 2.2 2.7 3.1 3.6 1750 3.
V olume ....................................................................................................... Up to 4.2 GPM Discharge Pressure ..................................................................................... Up to 2000 PSI Inlet Pressure .
Specifications Model P220A-3100/5100 V olume ....................................................................................................... Up to 4.7GPM Discharge Pressure ......................................................................
Specifications Model P221A-3100 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
ITE M PART NO. DESCRIPTION QTY. 1 08300 Crankcase 1 2 08301 Dipstick (Except P217, black ) 1 2 08480 Dipstick (P217, red ) 1 3 08302 Crankcase Plug Cover 1 3A 07190 Drain Plug & Gasket 1 4 08005 O-Ring 1 5 08185 Oil Drain Plug 1 6 07188-0100 Screw, 316 S.
Exploded View - P200A-3100/5100 Series Unique for P221- 3100 or.
REPAIR INSTRUCTION - P200A-3100/5100 SERIES Disassembly sequence of fluid end of P200A-3100/5100 series pump Note: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.
Disassembly sequence of the back end of the P200A-3100/5100 series pump. 1 ) Before you begin, drain the oil from the crankcase. 2) Remove the crankcase cover (3) and o-ring (4) from the crankcase (1). To remove the crankshaft (13), remove the bearing cover (7) and sight glass (8).
GIANT INDUSTRIES, INC. , 900 N. Westwood Ave., P.O. Box 3187, Toledo, Ohio 43607 PHONE (419) 531-4600, FAX (419) 531-6836, www.giantpumps.com Copyright 1998 Giant Industries, Inc. P200A-3100/5100 DIMENSIONS (mm) 3/98 P200A-3100.PM6 GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc.
An important point after buying a device Giant P200A-3100/5100 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Giant P200A-3100/5100 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Giant P200A-3100/5100 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Giant P200A-3100/5100 you will learn all the available features of the product, as well as information on its operation. The information that you get Giant P200A-3100/5100 will certainly help you make a decision on the purchase.
If you already are a holder of Giant P200A-3100/5100, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Giant P200A-3100/5100.
However, one of the most important roles played by the user manual is to help in solving problems with Giant P200A-3100/5100. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Giant P200A-3100/5100 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center