EN
Giant logo
Official user manual

Giant LP450

8 pages·390 KB·Water Pump·PDF·ENDEFRITNLJA
Giant LP450
Table of Contents 13 sections Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual · Models LP350, LP400, LP450 · Updated 3/98 · INSTALLATION INSTRUCTIONS · … ShowHide
Page 1 of the Giant LP450 user manual — Updated 3/98
Page 1 · click to enlarge
Page 1

Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Models LP350, LP400, LP450

Giant LP450 — Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual diagram (page 1)
Fig. 1 · Triplex Ceramic Plunger Pump Operating Instructions/…
Giant LP450 — Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual diagram (page 1)
Fig. 2 · Triplex Ceramic Plunger Pump Operating Instructions/…

Contents: Installation Instructions: page 2 Pump Specifications: pages 3-5 Exploded View/Parts: page 6 Repair Instructions: page 7 Kits/Torque Specs.: page 7 Dimensions: back page Warranty Information: back page

Updated 3/98

Page 2 of the Giant LP450 user manual — IMPORTANT OPERATING CONDITIONS
Page 2 · click to enlarge
Page 2

INSTALLATION INSTRUCTIONS

Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installa- tion. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance.

4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsation. Dampeners can also reduce the severity of pressure spikes that occur in systems using a shut-off gun. A dampener must be positioned downstream from the unloader.
1. The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication.
5. Crankshaft rotation on Giant Industries, Inc. pumps should be made in the direction designated by the arrows on the pump crankcase. Reverse rotation may be safely achieved by following a few guidelines available upon request from Giant Industries, Inc. Required horsepower for system operation can be obtained from the charts on pages 3-5.
2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joints. If pumps are to be operated at temperatures in excess of 140 0 F, it is important to insure a positive head to the pump to prevent cavitation.
6. Before beginning operation of your pumping system, remember: Check that the crankcase and seal areas have been properly lubricated per recommended schedules. Do not run the pump dry for extended periods of time. Cavitation will result in severe damage. Always remember to check that all plumbing valves are open and that pumped media can flow freely to the inlet of the pump.
3. The discharge plumbing from the pump should be properly sized to the flow rate to prevent line pressure loss to the work area. It is essential to provide a safety bypass valve between the pump and the work area to protect the pump from pressure spikes in the event of a blockage or the use of a shut-off gun.

Finally, remember that high pressure operation in a pump system has many advantages. But, if it is used carelessly and without regard to its potential hazard, it can cause serious injury.

IMPORTANT OPERATING CONDITIONS

Failure to comply with any of these conditions invalidates the warranty.

1. Prior to initial operation, add oil to the crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL.
2. Pump operation must not exceed rated pressure, volume, or RPM. A pressure relief device must be installed in the discharge of the system.

Use SAE 90 Industrial gear oil.

3. Acids, alkalines, or abrasive fluids cannot be pumped unless approval in writing is obtained before operation from Giant Industries, Inc.

Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.

4. Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures.
Page 3 of the Giant LP450 user manual — Specifications
Page 3 · click to enlarge
Page 3

Specifications

Model LP350 Volume Up to 22.6 GPM Discharge Pressure 2350 PSI Inlet Pressure Up to 90 PSI Maximum Crankshaft Speed Up to 1000 RPM Plunger Diameter 30mm Stroke 42mm Crankcase Oil Capacity 100 fl.oz. Temperature of Pumped Fluids 140 oF @1000 RPM

160 oF Up to 500 RPM Inlet Port 1-1/4" BSP Discharge Port 1" BSP Shaft Mounting Either side Shaft Rotation Top of pulley towards manifold Weight 105 lbs. Crankshaft Diameter 35mm

PULLEY INFORMATION Pulley selection and pump speed are based on a 1725 RPM motor and "B" section belts. When selecting desired GPM, allow for a ±5% tolerance on pumps output due to variations in pulleys, belts and motors among manufacturers. 1. Select GPM required, then select appropriate motor and pump pulley from the same line. 2. The desired pressure is achieved by selecting the correct nozzle size that corresponds with the pump GPM.

HORSEPOWER INFORMATION Horsepower ratings shown are the power require- ments for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend that a 1.1 service factor be specified when selecting an electric motor as the power source. To compute specific pump horsepower requirements, use the following formula:

HP = (GPM x PSI) / 1440

LP350 PULLEY SELECTION AND HORSEPOWER REQUIREMENTS PUMP PULLEYMOTOR PULLEYRPMGPM500 PSI1000 PSI2000 PSI2300 PSI 12.75"3.95"50011.33.97.815.718.0 12.75"4.95"64014.55.010.020.123.1 12.75"5.75"75016.95.911.823.527.1 12.75"6.15"80518.26.312.625.329.0 12.75"6.55"86519.56.813.627.131.2 12.75"6.95"94021.27.414.729.533.9 12.75"7.50"100022.67.815.731.436.1
Page 4 of the Giant LP450 user manual — Specifications
Page 4 · click to enlarge
Page 4

Specifications

Model LP400 Volume Up to 15.1 GPM Discharge Pressure 3600 PSI Inlet Pressure Up to 90 PSI Maximum Crankshaft Speed Up to 1000 RPM Plunger Diameter 24mm Stroke 42mm Crankcase Oil Capacity 100 fl.oz. Temperature of Pumped Fluids 140 oF @1000 RPM

160 oF Up to 500 RPM Inlet Port 1-1/4" BSP Discharge Port 1" BSP Shaft Mounting Either side Shaft Rotation Top of pulley towards manifold Weight 105 lbs. Crankshaft Diameter 35mm

PULLEY INFORMATION Pulley selection and pump speed are based on a 1725 RPM motor and "B" section belts. When selecting desired GPM, allow for a ±5% tolerance on pumps output due to variations in pulleys, belts and motors among manufacturers. 1. Select GPM required, then select appropriate motor and pump pulley from the same line. 2. The desired pressure is achieved by selecting the correct nozzle size that corresponds with the pump GPM.

HORSEPOWER INFORMATION Horsepower ratings shown are the power require- ments for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend that a 1.1 service factor be specified when selecting an electric motor as the power source. To compute specific pump horsepower requirements, use the following formula:

HP = (GPM x PSI) / 1440

LP400 PULLEY SELECTION AND HORSEPOWER REQUIREMENTS PUMP PULLEYMOTOR PULLEYRPMGPM2000 PSI2500 PSI3000 PSI3600 PSI 12.75"3.95"5007.510.513.115.718.8 12.75"4.95"6409.613.416.720.124.1 12.75"5.75"75011.315.719.623.528.2 12.75"6.15"80512.116.821.025.330.3 12.75"6.55"86513.018.122.627.132.6 12.75"6.95"94014.219.724.629.535.4 12.75"7.50"100015.120.926.131.437.6
Page 5 of the Giant LP450 user manual — Specifications
Page 5 · click to enlarge
Page 5

Specifications

Model LP450 Volume Up to 19.7 GPM Discharge Pressure 2600 PSI Inlet Pressure Up to 90 PSI Maximum Crankshaft Speed Up to 1000 RPM Plunger Diameter 28mm Stroke 42mm Crankcase Oil Capacity 100 fl.oz. Temperature of Pumped Fluids 140 oF @1000 RPM

160 oF Up to 500 RPM Inlet Port 1-1/4" BSP Discharge Port 1" BSP Shaft Mounting Either side Shaft Rotation Top of pulley towards manifold Weight 105 lbs. Crankshaft Diameter 35mm

PULLEY INFORMATION Pulley selection and pump speed are based on a 1725 RPM motor and "B" section belts. When selecting desired GPM, allow for a ±5% tolerance on pumps output due to variations in pulleys, belts and motors among manufacturers. 1. Select GPM required, then select appropriate motor and pump pulley from the same line. 2. The desired pressure is achieved by selecting the correct nozzle size that corresponds with the pump GPM.

HORSEPOWER INFORMATION Horsepower ratings shown are the power require- ments for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend that a 1.1 service factor be specified when selecting an electric motor as the power source. To compute specific pump horsepower requirements, use the following formula:

HP = (GPM x PSI) / 1440

LP450 PULLEY SELECTION AND HORSEPOWER REQUIREMENTS PUMP PULLEYMOTOR PULLEYRPMGPM1000 PSI1500 PSI2000 PSI2600 PSI 12.75"3.95"5009.86.810.313.717.8 12.75"4.95"64012.68.713.117.522.7 12.75"5.75"75014.810.315.420.526.7 12.75"6.15"80515.811.016.522.028.6 12.75"6.55"86517.011.817.723.630.7 12.75"6.95"94018.512.819.325.733.4 12.75"7.50"100019.713.720.527.335.5
Page 6 of the Giant LP450 user manual — LP350, LP400 & LP 450 PARTS LIST
Page 6 · click to enlarge
Page 6

LP350, LP400, LP450 - EXPLODED VIEW

Giant LP450 — LP350, LP400, LP450 - EXPLODED VIEW diagram (page 6)
Fig. 3

LP350, LP400 & LP 450 PARTS LIST

ITEM # PART # DESCRIPTION QTY 1 07759 Crankcase 1 2 13000 Oil filler plug assy. 1 4 06085 Crankcase Cover 1 5 07104 O-ring, Crankcase cover 1 6 07186 Oil Sightglass with Gasket 1 8 07105 Oil Dipstick 1 9 01009 O-Ring, Dipstick 1 10 01010 Cylinder Screw 4 11 01011 Spring Ring 5 12 07109 Plug 1 13 07110 Gasket 1 14 07111 Bearing Cover 2 15 07112 Radial Shaft Seal 2 16 07113 O-Ring 2 17 07114 Hexagon Screw 8 20 07116 Taper Roller Bearing 2 20A 07117 Fitting Disc 1-3 20B 13001 Fitting Disc 1-3 21 07118 Shaft Protector 1 22 13242 Crankshaft 1 23 13243 Woodruff Key 1 24 13340 Connecting Rod Assy. 3 25 13244 Crosshead / Plunger Assy. 3 28 13232 Crosshead Pin 3 29A 07256 Centering sleeve 3 29B 07261 Plunger Pipe (LP350) 3 29B 13046 Plunger Pipe (LP400) 3 29B 13005 Plunger Pipe (LP450) 3 29C 13007 Tensioning Screw 3 29D 07258 Copper Ring 3 30 07779 O-Ring 3 31 06120 Oil Seal Retainer Complete 3 31A 06118 Oil Seal 3 32 06116 Oil Seal Retainer 3 32A 06119 O-Ring 3

ITEM # PART # DESCRIPTION QTY 33 06117 Back Up Seal 3 35 13010 Seal Sleeve (LP350) 3 35 13392 Seal Sleeve (LP400) 3 35 13009 Seal Sleeve (LP450) 3 37 13011 Seal Case (LP350/LP450) 3 37 13393 Seal Case (LP400) 3 38 07140 O-Ring 3 38A 13012 O-Ring 3 39 07271 Pressure Ring (LP350) 3 39 12055 Pressure Ring (LP400) 3 39 13013 Pressure Ring (LP450) 3 40 13016 V-Sleeve (LP350) 6 40 06083 V-Sleeve (LP400) 6 40 13015 V-Sleeve (LP450) 6 41 07150 O-Ring (LP350) 3 41 13394 O-Ring (LP400) 3 41 07102 O-Ring (LP450) 3 42 07338 Pressure Spring (LP400) 3 43 13018 Valve Casing 1 44A 07150 O-Ring 9 46 07060 Valve Assy. 6 46A 07064 Valve Seat 6 46B 07063 Valve Plate 6 46C 07062 Valve Spring 6 46D 07066 Spacer Pipe 6 48 07156 Plug 3 49 07754 Stud bolt 8 49A 07158 Hexagon Nut 8 49B 07159 Disc 8 50 07160-0100 Plug 1 50A 07161 Copper Ring 1 51 13019 Plug 3 51A 07676 Copper Ring 3 52 13020 Disc for Crankshaft 1 53 13021 Hexagon Screw 1

Page 7 of the Giant LP450 user manual — LP350, LP400 & LP450 KITS
Page 7 · click to enlarge
Page 7

REPAIR INSTRUCTION - LP350, LP400, LP450

VALVE REPLACEMENT 1) With a 30mm wrench remove the three (3) tension plugs (#48) from top of valve casing (43). 2) Remove discharge and inlet valves (#46), pulling them upwards out of the valve casing. It maybe necessary to use a slide hammer tool. 3) With the valve assembly pointed down, place a dowel rod through the top of valve cage. Hold assembly in hand and tap end of dowel sharply with mallet until assembly pops free. 4) Inspect valve seats (#46A) and valve plates (#46B) for damage and replace if needed. 5) Check valve casing (#43) surfaces for damage. 6) Replace o-rings (#44A) and reinstall valve assemblies into valve casing. (Lubricate o-rings before installation.) 7) Replace tension plugs (#48) and tighten them securely.

SEAL AND PLUNGER REPLACEMENT 1) Remove the eight (8) manifold nuts and washers (#49A,B) using a 19mm wrench and pull off valve casing (#43). If needed, tap valve casing with a rubber mallet to remove it. 2) Pull seal sleeve (#35) out of crankcase guides. 3) Remove seal case (#37) from seal sleeve. 4) Check plunger surface for wear and pitting. If none is found, proceed to step eleven. 5) If plunger (#29B) is worn, remove tension screw (#29C) with a 17mm wrench. Clean tension screw with wire brush to remove any old locktite. 6) Discard copper gasket (#29D) and replace with new. 7) Clean the front surface of plunger/ crosshead assembly (#25). 8) Install new plunger (#29B) onto plunger/ crosshead assembly. 9) Put some locktite on both surfaces of copper gasket (#29D) and tension screw threads (#29C). 10) Secure plunger in place with tension screw (#29C) and gasket (#29D) and tighten to 33 ft. lbs. 11) Remove v-sleeves (#40) and o-ring (#41) for seal case and replace with new. Lubricate parts before reinstalling. 12) Replace seal case (#35) and seal sleeve (#37) into valve casing. Replace nuts and washers (#49A,B) and tighten to 59 ft. lbs.

DISASSEMBLY OF CRANKCASE 1) Remove valve casing (#43) and plunger pipe (#28B), drain oil. 2) Screw off gear cover (#4) and bearing cover (#14). 3) Remove connecting rod screws (#24) and push the front of connecting rod forward as far as possible. Remove back halves of connecting rods, note which position from which they came from. 4) Turning the crankshaft slightly, carefully hit on side of crankshaft (#22) with a rubber mallet until crankshaft is loose. 5) Check crankshaft and bearing for damage, replace if needed.

REASSEMBLY 6) Using a soft tool, press in the outer bearing ring until the outer edge lines up with the outer edge of crankcase (#1). Attach bearing cover (#14) with shaft seal and o-ring (#16) in place. Fit crankshaft through bearing hole on the opposite side. Press in bearing with bearing cover, keeping the shaft in a horizontal position and turning it slowly so that taper rollers touch the edge of outer bearing ring. 7) Adjust axial bearing clearance to at least .004" and maximum at .006 by placing fitting discs (#20A & 20B) under the bearing cover. 8) After assembly the shaft should turn easily with very little clearance. 9) Bolt connecting rod halves together making sure they are replaced in the same position from which they came from. Tighten connecting rod screws to 264 in.-lbs.

LP350, LP400 & LP450 KITS

TORQUE SPECIFICATIONS

Valve Kit #09196 Qty Part # Description 1 7064 Valve seat 1 7063 Valve plate 1 7062 Valve spring Packing Kit, LP350 #09233 Qty Part # Description 6 13016 V-sleeve 3 7150 O-ring 3 13012 O-ring 3 7140 O-ring

Packing Kit, LP400 #09309 Qty Part # Description 6 06083 V-sleeve 3 13349 O-ring 3 13012 O-ring 3 7140 O-ring

Position Description Torque Amount 24 Connecting Rod 264 in.-lbs. 29C Tensioning Screw 33 ft.-lbs. 49A Hexagon Nut 59 ft.-lbs.

Packing Kit LP450 #09234 Qty Part # Description 6 13015 V-Sleeve 3 7102 O-ring 3 13012 O-ring 3 7140 O-ring

Page 8 of the Giant LP450 user manual — GIANT INDUSTRIES LIMITED WARRANTY
Page 8 · click to enlarge
Page 8

LP350, LP400 & LP 450 DIMENSIONS (metric)

Giant LP450 — LP350, LP400 & LP 450 DIMENSIONS (metric) diagram (page 8)
Fig. 4 · LP350, LP400 & LP 450 DIMENSIONS (metric)

GIANT INDUSTRIES LIMITED WARRANTY

Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows:

1. For portable pressure washers and car wash applications, the discharge manifolds will never fail, period. If they ever fail, we will replace them free of charge. Our other pump parts, used in portable pressure washers and in car wash applications, are warranted for five years from the date of shipment for all pumps used in NON- SALINE, clean water applications. 2. One (1) year from the date of shipment for all other Giant industrial and consumer pumps. 3. Six (6) months from the date of shipment for all rebuilt pumps. 4. Ninety (90) days from the date of shipment for all Giant accessories.

This warranty is limited to repair or replacement of pumps and accessories of which the manufacturer’s evaluation shows were defective at the time of shipment by the manufacturer. The following items are NOT covered or will void the warranty:

1. Defects caused by negligence or fault of the buyer or third party. 2. Normal wear and tear to standard wear parts. 3. Use of repair parts other than those manufactured or authorized by Giant. 4. Improper use of the product as a component part. 5. Changes or modifications made by the customer or third party. 6. The operation of pumps and or accessories exceeding the specifications set forth in the Operations Manuals provided by Giant Industries, Inc.

Liability under this warranty is on all non-wear parts and limited to the replacement or repair of those products returned freight prepaid to Giant Industries which are deemed to be defective due to workmanship or failure of material. A Returned Goods Authorization (R.G.A.) number and completed warranty evaluation form is required prior to the return to Giant Industries of all products under warranty consideration. Call (419)-531-4600 or fax (419)-531-6836 to obtain an R.G.A. number.

Repair or replacement of defective products as provided is the sole and exclusive remedy provided hereunder and the MANUFACTURER SHALL NOT BE LIABLE FOR FURTHER LOSS, DAMAGES, OR EXPENSES, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES DIRECTLY OR INDIRECTLY ARISING FROM THE SALE OR USE OF THIS PRODUCT.

THE LIMITED WARRANTY SET FORTH HEREIN IS IN LIEU OF ALL OTHER WARRANTIES OR REPRESENTATION, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRAN- TIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ALL SUCH WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED BY THE MANUFACTURER.

GIANT INDUSTRIES, INC., 900 N. Westwood Ave., P.O. Box 3187, Toledo, Ohio 43607 PHONE (419) 531-4600 FAX (419) 531-6836 www.giantpumps.com Ó Copyright 1998 Giant Industries, Inc.

Ó Copyright 1998 Giant Industries, Inc.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Giant LP450

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Giant LP450

Be the first to ask — other owners or our team will answer.

Original document

Giant LP450 manual PDF

8 pages·390 KB·Water Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…