EN
Giant logo
Official user manual

Giant LP122A

12 pages·188 KB·Coffeemaker·PDF·ENDEFRITNLJA
Giant LP122A
Table of Contents 30 sections Triplex Ceramic · Plunger Pump Operating Instructions/ Repair and Service Manual · Models LP122A/LP122A-4000/LP123/LP255 · INSTALLATION INSTRUCTIONS · … ShowHide
Page 1 of the Giant LP122A user manual — Triplex Ceramic
Page 1 · click to enlarge
Page 1

Triplex Ceramic

Plunger Pump Operating Instructions/ Repair and Service Manual

Models LP122A/LP122A-4000/LP123/LP255

Giant LP122A — Triplex Ceramic diagram (page 1)
Fig. 1 · Triplex Ceramic

Contents: Installation Instructions: page 2 Pump Specifications - LP122A/LP122A-4000 page 3 Pump Specifications - LP123: page 3 Exploded View: page 4 Parts List/Kits: page 5 Pump Specifications - LP255: page 6 Trobleshooting Guide: page 7 Suggested Maintenance Schedule: page 7 Repair Instructions/Torque Specs.: pages 8-10 Dimensions: page 11 Warranty Information: back page Updated 12/06

Giant LP122A — Triplex Ceramic diagram (page 1)
Fig. 2 · Triplex Ceramic
Page 2 of the Giant LP122A user manual — NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600
Page 2 · click to enlarge
Page 2

INSTALLATION INSTRUCTIONS

Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance.

4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsation. Dampeners can also reduce the severity of pressure spikes that occur in systems using a shut-off gun. A dampener must be positioned downstream from the unloader.
1. The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication.
5. Crankshaft rotation on Giant Industries, Inc. pumps should be made in the direction designated by the arrows on the pump crankcase. Reverse rotation may be safely achieved by following a few guidelines available upon request from Giant Industries, Inc. Required horsepower for system operation can be obtained from the charts on pages 3 and 6.
2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joints. If pumps are to be operated at temperatures in excess of 160 0

F, it is important to insure a positive head to the pump to prevent cavitation. See NPSH curve for LP122A Series/ LP123 pumps.

6. Before beginning operation of your pumping system, remember: Check that the crankcase and seal areas have been properly lubricated per recommended schedules. Do not run the pump dry for extended periods of time. Cavitation will result in severe damage. Always remember to check that all plumbing valves are open and that pumped media can flow freely to the inlet of the pump.
3. The discharge plumbing from the pump should be properly sized to the flow rate to prevent line pressure loss to the work area. It is essential to provide a safety bypass valve between the pump and the work area to protect the pump from pressure spikes in the event of a blockage or the use of a shut-off gun.
Giant LP122A — INSTALLATION INSTRUCTIONS diagram (page 2)
Fig. 3

LP122A/LP123 NPSHR Curve

Finally, remember that high pressure operation in a pump system has many advantages. But, if it is used carelessly and without regard to its potential hazard, it can cause serious injury.

IMPORTANT OPERATING CONDITIONS

Failure to comply with any of these conditions invalidates the warranty.

1. Prior to initial operation, add oil to the crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL.
2. Pump operation must not exceed rated pressure, volume, or RPM. A pressure relief device must be installed in the discharge of the system.

Use SAE 90 Industrial gear oil (Giant’s p/n 01154)

3. Acids, alkalines, or abrasive fluids cannot be pumped unless approval in writing is obtained before operation from Giant Industries, Inc.

Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.

4. Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures.

NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600

Page 3 of the Giant LP122A user manual — *Intermittent duty only! - Consult factory!
Page 3 · click to enlarge
Page 3

Specifications Models LP122A/LP122A-4000/LP123

U.S (Metric) Volume (Continuous) 35.4 GPM (134 l/m) Volume (Intermittent) 40 GPM (151.4 l/m) Discharge Pressure (Continuous) 1300 PSI (90 Bar) Discharge Pressure (Intermittent) 2000 PSI (138 Bar) Inlet Pressure Up to 90 PSI (Up to 6.2 Bar) Speed (Continuous) Up to 800 RPM* Speed (Intermittent) Up to 885 RPM** Plunger Diameter 1.65” (42 mm) Stroke 1.65” (42 mm) Crankcase Oil Capacity 116 fl.oz (3.43 liters) Temperature of Pumped Fluids Up to 160oF (Up to 71oC) Inlet Ports 2 x 1-1/2" NPT Discharge Ports 2 x 1" NPT Crankshaft Mounting Either Side Shaft Rotation Top of Pulley Towards Fluid End Weight 116 lbs (52.7 Kg) Crankshaft Diameter 1.38” (35 mm) Valve Casing - LP122A Aluminum Bronze Valve Casing - LP123 Brass Valve Casing - LP122A-4000 303 S.S. Volumetric Efficiency @ 800 RPM 0.96 Mechanical Efficiency @ 800 RPM 0.85

*Pump speeds of 640 RPM and above require a minimum inlet pressure of 12 psig. **Pump speeds of 805 RPM and above require a minimum inlet pressure of 14 psig.

PULLEY INFORMATION Pulley selection and pump speed are based on a 1725 RPM motor and "B" section belts. When selecting desired GPM, allow for a ±5% toler- ance on pumps output due to variations in pulleys, belts and motors among manufactur- ers. 1. Select GPM required, then select appropriatemotor and pump pulley from the same line.

2. The desired pressure is achieved by selecting the correct nozzle size that corresponds with the pump GPM.

HORSEPOWER INFORMATION We recommend that a 1.1 service factor be speci- fied when s electing an electric motor as the power source. To compute specific pump horsepower requirements, use the following formula:

HP = (GPM X PSI) / 1440

LP122A/LP122A-4000/LP123 PULLEY SELECTION AND HORSEPOWER REQUIREMENTS GPMPUMP PULLEYMOTOR PULLEYRPM600 PSI800 PSI1000 PSI1300 PSI2000 PSI* 22.312.75"3.95"5009.612.715.920.731.9 24.712.75"4.35"55510.614.117.622.935.3 28.512.75"4.95"64012.216.320.426.540.7 30.912.75"5.35"69513.217.722.128.744.1 33.412.75"5.75"75014.319.123.931.047.7 35.612.75"6.15"80015.320.325.433.150.9 39.412.75"6.50"885*16.922.528.136.656.3

*Intermittent duty only! - Consult factory!

Page 4 of the Giant LP122A user manual — Exploded View - LP122A/LP122A-4000/LP123/LP255
Page 4 · click to enlarge
Page 4

Exploded View - LP122A/LP122A-4000/LP123/LP255

Giant LP122A — Exploded View - LP122A/LP122A-4000/LP123/LP255 diagram (page 4)
Fig. 4 · Exploded View - LP122A/LP122A-4000/LP123/LP255
Page 5 of the Giant LP122A user manual — A = LP122A B = LP123 C = LP122-4000 E = LP255
Page 5 · click to enlarge
Page 5

LP122A/LP122A-4000/LP123/LP255 PARTS LIST

A = LP122A B = LP123 C = LP122-4000 E = LP255

ITEM PART NO. DESCRIPTION QTY. 1 07759 Crankcase 1 2 13000 Oil Filler Plug 1 4 06085 Crankcase Cover 1 5 07104 O-Ring 1 6 07186 Oil Sight Glass W/Gasket 1 8 06086 Oil Dipstick 1 9 01009 O-Ring 1 10 01010 Screw, (A, B, C, E) 4 11 01011-0400 Spring Washer, (A, B, C) 5 12 07109 Oil Drain Plug 1 13 07182 Gasket 1 14 07111 Bearing Cover 2 15 07112 Crankshaft Seal 2 16 07113 O-Ring 2 17 07114 Hex Screw 8 20 07116 Taper Roller Bearing 2 20A 07117 Fitting Disc, 0.1mm 2 20B 13001 Fitting Disc, 0.15mm 3 21 07118 Shaft Protector 1 22 13242 Crankshaft 1 23 13243 Key 1 24 13340 Connecting Rod Assy. 3 24A 13277 Hex Screw 6 24B 13278 Spring Washer 6 25 13341 Crosshead Plunger Base Assy. 3 28 13232 Crosshead Pin 3 29A 07735 Centering Sleeve 3 29B 07736 Plunger Pipe (A-C) 3 29B 13022 Plunger Pipe (E) 3 29C 07737 Plunger Bolt 3 29D 07755 Copper Gasket 3 29E 06087 Spacer Pipe 3 30 07789 Flinger 3 31 07133 Radial Shaft Seal 3 35 13342 Seal Sleeve, (A, B, C) 3 35 06699 Seal Sleeve (E) 3 35A 07740 O-Ring 3

ITEM PART NO. DESCRIPTION QTY. 35B 13141 O-Ring (E only) 3 36 13415 V-Sleeve, Weep (A-C) 3 36 13025 V-Sleeve, Weep (E) 3 36A 13416A Pressure Ring, Weep, (A, B, C) 3 36A 06700 Pressure Ring (E) 3 37 06701 Support Disc (E only) 3 39 07744 Pressure Ring, (A, B, C) 3 39 13026 Pressure Ring (E) 6 40 07745 V-Sleeve (A, B, C, D) 6 40 13027 V-Sleeve (E) 6 41 07746 Support Ring, (A, B, C) 3 41 06702 Support Ring (E) 3 43 13343 Valve Casing, (A) 1 43 06625 Valve Casing, (B) 1 43 13343-4000 Valve Casing, (C) 1 43 06703 Valve Casing, (E) 1 44 07748 Valve Seat 6 44A 07150 O-Ring 6 45 07749 Valve Plate 6 46 07750 Valve Spring 6 46A 07751 Valve Assy. Complete (#44, 44A, 45, 46, & 47) 6 47 07752 Spring Retainer 6 48 07753 Plug, (A) 6 48 06504 Plug, (B, E) 6 48 06089 Plug, (C) 6 48A 12055 O-Ring 6 49 07157 Stud Bolt 8 49A 07158 Nut 8 49B 07159 Washer 8 50 07423 Plug, (A,B, E) 1 50 07423-0100 Plug, (C) 1 50A 07161 Gasket 1 52 13020 Disk for Crankshaft 1 53 06607 Hexagon Screw 1 54 07756 Plug 1" NPT, (A, C) 1 54 06626 Plug 1" NPT, (B, E) 1 55 07757 Plug 1-1/2" NPT, (A, C) 1 55 06627 Plug, 1-1/4" NPT, (B, E) 1

(36) to the newer style (p/n 13416) and use the new style weep seal (p/n 13415) in your pumps.

LP122A/LP122A-4000/LP123/LP255 PUMP REPAIR KITS Plunger Packing Kit # 09477 (LP122A, LP123, LP122A-4000) (for pumps manufatured after 4/98) Item Part # Description Qty. 35A 07740 O-ring 3 36 13415 V-Sleeve, Weep 3 40 07745 V-Sleeve 6 Plunger Packing Kit # 09535 (LP255) Item Part # Description Qty. 35A 07740 O-ring 3 35B 13141 O-Ring 3 36 13025 V-Sleeve weep 3 40 13027 V-Sleeve 6

Valve Assembly Kit - #09136 Item Part # Description Qty. 46A 07751 Valve Assembly, Complete 3 48A 12055 O-Ring 3

Page 6 of the Giant LP122A user manual — HP = (GPM X PSI) / 1440
Page 6 · click to enlarge
Page 6

Specifications

Model LP255

U.S (Metric) Volume 26.0 GPM (98 l/min) Discharge Pressure 2175 PSI 150 Bar) Inlet Pressure Up to 90 PSI Up to 6.2 Bar) Speed Up to 1000 RPM Plunger Diameter 1.26” (32 mm) Stroke 1.65” (42 mm) Crankcase Oil Capacity 116 fl.oz (3.43 liters) Temperature of Pumped Fluids Up to 160oF (70 oC) Inlet Ports 2 x 1-1/2" NPT Discharge Ports 2 x 1" NPT Crankshaft Mounting Either Side Shaft Rotation Top of Pulley Towards Fluid End Weight 116 lbs (52.7 Kg) Crankshaft Diameter 1.38” (35 mm) Valve Casing Brass Volumetric Efficiency @ 800 RPM 0.96 Mechanical Efficiency @ 800 RPM 0.85

PULLEY INFORMATION Pulley selection and pump speed are based on a 1725 RPM motor and "B" section belts. When selecting desired GPM, allow for a ±5% tolerance on pumps output due to variations in pulleys, belts and motors among manufacturers. 1. Select GPM required, then select appropriate motor and pump pulley from the same line. 2. The desired pressure is achieved by selecting the correct nozzle size that corresponds with the pump GPM.

HORSEPOWER INFORMATION We recommend that a 1.1 service factor be speci- fied when s electing an electric motor as the power source. To compute specific pump horsepower requirements, use the following formula:

HP = (GPM X PSI) / 1440

LP255 PULLEY SELECTION AND HORSEPOWER REQUIREMENTS PUMP PULLEYMOTOR PULLEYRPMGPM1000 PSI1500 PSI2000 PSI2175 PSI 12.75"3.95"500139.013.518.119.6 12.75"4.35"64016.611.517.323.125.1 12.75"4.95"75019.513.520.327.129.5 12.75"5.35"80520.914.521.829.031.6 12.75"5.75"86522.515.623.431.334.0 12.75"6.15"92023.916.624.933.236.1 12.75"6.50"10002618.127.136.139.3
Page 7 of the Giant LP122A user manual — Preventative Maintenance Check-List & Recommended Spare Parts List
Page 7 · click to enlarge
Page 7

PUMP SYSTEM MALFUNCTION

MALFUNCTION CAUSE REMEDY

The Pressure and/ Worn packing seals Replace packing seals or the Delivery Broken valve spring Replace spring Drops Belt slippage Tighten or Replace belt Worn or Damaged nozzle Replace nozzle Fouled discharge valve Clean valve assembly Fouled inlet strainer Clean strainer Worn or Damaged hose Repair/Replace hose Worn or Plugged relief valve on pump Clean, Reset, and Replace worn parts Cavitation Check suction lines on inlet of pump for restrictions Unloader Check for proper operation

Water in crankcase High humidity Reduce oil change interval Worn seals Replace seals

Noisy Operation Worn bearings Replace bearings, Refill crankcase oil with recommended lubricant Cavitation Check inlet lines for restrictions and/or proper sizing

Rough/Pulsating Worn packing Replace packing Operation with Inlet restriction Check system for stoppage, air Pressure Drop leaks, correctly sized inlet plumbing to pump Accumulator pressure Recharge/Replace accumulator Unloader Check for proper operation Cavitation Check inlet lines for restrictions and/or proper size

Pump Pressure as Restricted discharge plumbing Re-size discharge plumbing to Flow Rated, Pressure Rate of Pump Drop at Gun

Excessive Worn plungers Replace plungers Leakage Worn packing/seals Adjust or Replace packing seals Excessive vacuum Reduce suction vacuum Cracked plungers Replace plungers Inlet pressure too high Reduce inlet pressure

High Crankcase Wrong Grade of oil Giant oil is recommended Temperature Improper amount of oil in crankcase Adjust oil level to proper amount

Preventative Maintenance Check-List & Recommended Spare Parts List

Check Daily Weekly 50hrs Every Every Every 500 hrs 1500 hrs 3000 hrs

Oil Level/Quality X Oil Leaks X Water Leaks X Belts, Pulley X Plumbing X Recommended Spare Parts Oil Change (1 Gallon) p/n 1154 X X Seal Spare Parts (1 kit/pump) X (See page 5 for kit list) Oil Seal Kit (1 kit/pump) X (See page 5 for kit lit) Valve Spare Parts (1 kit/pump) X (See page 5 for kit list)

Page 8 of the Giant LP122A user manual — 44A 44 45 48 47
Page 8 · click to enlarge
Page 8

LP122A/LP122A-4000/LP123/LP255 - Repair Instructions

Giant LP122A — LP122A/LP122A-4000/LP123/LP255 - Repair Instructions diagram (page 8)
Fig. 5 · LP122A/LP122A-4000/LP123/LP255 - Repair Instructions
Giant LP122A — LP122A/LP122A-4000/LP123/LP255 - Repair Instructions diagram (page 8)
Fig. 6 · LP122A/LP122A-4000/LP123/LP255 - Repair Instructions

44A 44 45 48 47

1. With a 30mm wrench, remove the six (6) plugs (48) from the valve casing (43). Inspect the orings (48A) and replace if necessary. Remove the complete valve assembly (46A) by threading a 12mm bolt into the spring retainer and pulling straight out.
2. To disassemble the valve, screw the bolt into the retainer until the valve plate (45) presses the valve seat (44) out of the spring retainer. Examine all parts and replace if necessary. If the seat doesn’t come out, use a valve puller to remove.
Giant LP122A — 44A 44 45 48 47 diagram (page 8)
Fig. 7
Giant LP122A — 44A 44 45 48 47 diagram (page 8)
Fig. 8

36A 36 35 35A 35B 39 40 40 41 37 (LP255 only) (LP255 only)

3. Remove the eight (8) hex nuts (49A) with a 19mm wrench. Tap the back of the manifold (43) with a rubber mallet to dislodge and slide off the studs.
4. Remove the seal sleeve (35) from the manifold and/or crankcase. Remove the pressure rings (39&36A), v-sleeves (40&36), support ring (41) and o-rings (35A and 35B in Lp255A only) from the manifold and seal sleeve, respectively. For LP255 only, remove support ring (37). Examine seals carefully and replace if worn. Clean all parts.
Giant LP122A — 44A 44 45 48 47 diagram (page 8)
Fig. 9
5. If there are signs of oil leaking through the plunger oil seals, then replacment is neccessary. Dissassemble the gear end and push out the seals from the back of the pump. 29E 29A 29B 29D 29C
6. Inspect surface of plunger pipe (29B) carefully. Remove any chemical or mineral deposits taking care not to damage the surface of the plunger. If plunger pipe is worn, remove the plunger bolt (29C) , plunger pipe (29B) and spacer (29E). Replace worn parts necessary. Note: Always use a new copper gasket (29) when repairing the plunger assembly.
Page 9 of the Giant LP122A user manual — 29E 29A 29B 29D 29C
Page 9 · click to enlarge
Page 9

LP122A/LP122A-4000/LP123/LP255 - Repair Instructions

TO REASSEMBLE PROCEED AS FOLLOWS:

Giant LP122A — TO REASSEMBLE PROCEED AS FOLLOWS: diagram (page 9)
Fig. 10

29E 29A 29B 29D 29C

7. If previously disassembled thoroughly clean all exposed surfaces on the spacer (29E) and all exposed threads on the plunger bolt (29C) and the steel plunger base (25). Threads MUST be free of old loc-tite and any other material such as oil, grease, etc. This is necessary to ensure proper curing of new loc-tite. Giant recommends cleaning the threads with acetone or other suitable cleaner. Reassemble plunger assembly parts (29A, 29B, & 29E) using a new copper gasket (29D) and the cleaned plunger bolt (29C). Slide the bolt through the center of the four (4) pieces so that the threaded end is exposed. Apply several drops of loc-tite 243 (or equivalent) adhesive to the threads. Thread into steel plunger base and tighten to 26 ft.-lbs. BE CERTAIN ALL PARTS ARE CENTERED WITH THE BOLT!

Giant LP122A — 29E 29A 29B 29D 29C diagram (page 9)
Fig. 11
Giant LP122A — 29E 29A 29B 29D 29C diagram (page 9)
Fig. 12

36A 36 35 35A 35B (LP255 only) 39

8. Lubricate weep seal (36). Place, weep seal (36), and pressure ring (36A) into the seal sleeve (35). Assemble the o-ring (35A and 35B for LP255 only) onto seal sleeve and lubricate.
9. For LP255 pumps, insert support ring (37) into valve casing (43). Place support ring (41) and v-sleeves (40) into valve casing.
Giant LP122A — 29E 29A 29B 29D 29C diagram (page 9)
Fig. 13
Giant LP122A — 29E 29A 29B 29D 29C diagram (page 9)
Fig. 14

6 4 2 7

8 1 3 5

10. Place entire manifold/seal sleeve assembly over the studs and push firmly until seated against the crankcase.
11. Tighten hex nuts (49A) in a crosswise pattern (shown above) to 60 ft.-lbs.
Page 10 of the Giant LP122A user manual — Contact Giant Industries or your local distributor for maintenance
Page 10 · click to enlarge
Page 10

LP122A/LP122A-4000/LP123/LP255 - Repair Instructions

Giant LP122A — LP122A/LP122A-4000/LP123/LP255 - Repair Instructions diagram (page 10)
Fig. 15 · LP122A/LP122A-4000/LP123/LP255 - Repair Instructions
Giant LP122A — LP122A/LP122A-4000/LP123/LP255 - Repair Instructions diagram (page 10)
Fig. 16 · LP122A/LP122A-4000/LP123/LP255 - Repair Instructions
14. Fill crankcase with approximately 116 fluid ounces of Giant oil or equivalent SAE 90 industrial gear oil and check oil level of the crankcase with the dipstick. Proper level is center of two lines. Reinstall your Giant LP pump into your system.
12. Next, place valve assemblies (46A) into manifold after first lubricating the o-ring (44A). Seat firmly into manifold.
13. Replace plug with o-ring (48, & 48A) and tighten to 160 ft.-lbs.

LP122A/LP122A-4000/LP123/LP255 TORQUE SPECIFICATIONS

Position Item# Description Torque Amount 10 01010 Screw, Cover 125 in.-lbs. 17 07114 Hex Screw, Bearing Cover 125 in.-lbs. 24A 13277 Hex Screw, Connecting Rod 250 in.-lbs. 29C 07737 Plunger Bolt 26 ft.-lbs. 48 06504/06089 Plug, Valve 160 ft.-lbs. 49A 07158 Nut, Stud Bolt 60 ft.-lbs.

Contact Giant Industries or your local distributor for maintenance

of the gear end of your pump. Phone: 419/531-4600

Contact Giant Industries for service school information. Phone: (419) 531-4600

Page 11 of the Giant LP122A user manual — LP122A-4000 Dimensions (mm)
Page 11 · click to enlarge
Page 11

LP122A/LP123/LP255 Dimensions (mm)

Giant LP122A — LP122A/LP123/LP255 Dimensions (mm) diagram (page 11)
Fig. 17 · LP122A/LP123/LP255 Dimensions (mm)

LP122A-4000 Dimensions (mm)

Giant LP122A — LP122A-4000 Dimensions (mm) diagram (page 11)
Fig. 18 · LP122A-4000 Dimensions (mm)
Page 12 of the Giant LP122A user manual — 12/06 LP122A_LP123_LP255.PMD
Page 12 · click to enlarge
Page 12

GIANT INDUSTRIES LIMITED WARRANTY

Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in

workmanship and material as follows:

1. For portable pressure washers and self-service car wash applications, the discharge manifolds will never

fail, period. If they ever fail, we will replace them free of charge. Our other pump parts, used in portable

pressure washers and in car wash applications, are warranted for five years from the dateof shipment for

all pumps used in NON-SALINE, clean water applications.

2. One (1) year from the date of shipment for all other Giant industrial and consumer pumps.
3. Six (6) months from the date of shipment for all rebuilt pumps.
4. Ninety (90) days from the date of shipment for all Giant accessories.

This warranty is limited to repair or replacement of pumps and accessories of which the manufacturer’s evaluation

shows were defective at the time of shipment by the manufacturer. The following items are NOT covered or will

void the warranty:

1. Defects caused by negligence or fault of the buyer or third party.
2. Normal wear and tear to standard wear parts.
3. Use of repair parts other than those manufactured or authorized by Giant.
4. Improper use of the product as a component part.
5. Changes or modifications made by the customer or third party.
6. The operation of pumps and or accessories exceeding the specifications set forth in the Operations

Manuals provided by Giant Industries, Inc.

Liability under this warranty is on all non-wear parts and limited to the replacement or repair of those products

returned freight prepaid to Giant Industries which are deemed to be defective due to workmanship or failure of

material. A Returned Goods Authorization (R.G.A.) number and completed warranty evaluation form is required prior

to the return to Giant Industries of all products under warranty consideration. Call (419)-531-4600 or fax (419)-531-

6836 to obtain an R.G.A. number.

Repair or replacement of defective products as provided is the sole and exclusive remedy provided hereunder and

the MANUFACTURER SHALL NOT BE LIABLE FOR FURTHER LOSS, DAMAGES, OR EXPENSES, INCLUDING

INCIDENTAL AND CONSEQUENTIAL DAMAGES DIRECTLY OR INDIRECTLY ARISING FROM THE SALE OR USE

OF THIS PRODUCT.

THE LIMITED WARRANTY SET FORTH HEREIN IS IN LIEU OF ALL OTHER WARRANTIES OR REPRESENTATION,

EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OR MERCHANTABILITY OR

FITNESS FOR A PARTICULAR PURPOSE AND ALL SUCH WARRANTIES ARE HEREBY DISCLAIMED AND

EXCLUDED BY THE MANUFACTURER.

GIANT INDUSTRIES, INC., 900 N. Westwood Avenue, P.O. Box 3187, Toledo, OH 43607 PHONE: (419) 531-4600, FAX: (419) 531-6836, www.giantpumps.com Copyright 2006 Giant Industries, Inc.

12/06 LP122A_LP123_LP255.PMD

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Giant LP122A

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Giant LP122A

Be the first to ask — other owners or our team will answer.

Original document

Giant LP122A manual PDF

12 pages·188 KB·Coffeemaker·PDF
Click any page above to open it here
Page 1 / …
100%