Table of Contents 31 sections Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual · Models HR2527A/HR3025/ HR3030 Pumps · Consumer Pumps · HR2527A shown · … ShowHide
Page 1 of the Giant HR3025 user manual — MADE IN THE USA
Page 1 · click to enlarge
Page 1

Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Models HR2527A/HR3025/ HR3030 Pumps

Giant HR3025 — Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual diagram (page 1)
Fig. 1 · Triplex Ceramic Plunger Pump Operating Instructions/…

Consumer Pumps

HR2527A shown

Giant HR3025 — Consumer Pumps diagram (page 1)
Fig. 2 · Consumer Pumps

Contents: Installation Instructions: page 2 Pump Specifications: pages 3-5 Exploded View: page 6 Parts List: page 7 Kits/Torgue Specs: page 8 Touble Shooting page 9 Repair Instructions: page 10-11 Dimensions/Warranty: back page

MADE IN THE USA

Updated 5/02

Page 2 of the Giant HR3025 user manual — NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600
Page 2 · click to enlarge
Page 2

INSTALLATION INSTRUCTIONS

Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installa- tion. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance.

between the pump and the work area to protect the pump from pressure spikes in the event of a blockage or the use of a shut-off gun.

4. Reverse rotation may be safely achieved by following a few guidelines available upon request from Giant Industries, Inc. Required horsepower for system operation can be obtained from the charts on pages 3 and 6.
1. The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication.
5. Before beginning operation of your pumping system, remember: Check that the crankcase and seal areas have been properly lubricated per recommended schedules. Do not run the pump dry for extended periods of time. Cavitation will result in severe damage. Always remember to check that all plumbing valves are open and that pumped media can flow freely to the inlet of the pump.
2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joints. If pumps are to be operated at temperatures in excess of 80 0 F, it is important to insure a positive head to the pump to prevent cavitation.
3. The discharge plumbing from the pump should be properly sized to the flow rate to prevent line pressure loss to the work area. It is essential to provide a safety bypass valve

Finally, remember that high pressure operation in a pump system has many advantages. But, if it is used carelessly and without regard to its potential hazard, it can cause serious injury.

IMPORTANT OPERATING CONDITIONS

Failure to comply with any of these conditions invalidates the warranty.

1. Crankcase oil should be changed after the first 50 hours of operation. Then at regular intervals of 500 hours or less depending on operating conditions.
3. Acids, alkalines, or abrasive fluids cannot be pumped unless approval in writing is obtained before operation from Giant Industries, Inc.
4. Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures.

Use Giant synthetic oil

2. Pump operation must not exceed rated pressure, volume, or RPM. A pressure relief device must be installed in the discharge of the system.

NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600

Page 3 of the Giant HR3025 user manual — RPM .....................................................................................................3450
Page 3 · click to enlarge
Page 3

Specifications Model HR2527A

Axial Pump

Volume HR2527A 2.5 GPM

Maximum Discharge Pressure 2750 PSI

Maximum Inlet Pressure Up to 90 PSIG1

RPM 3450

Plunger Diameter 16mm

Stroke 5.3mm (7.1 o angle)

Crankcase Oil Capacity 4.5 fl. oz.

Temperature of Pumped Fluids Up to 80 oF

Inlet Port 1 x 1/2" NPT

Discharge Ports 3/8" NPT

Shaft Rotation Clockwise

Weight 11.7 lbs. (12.7 lbs.)

Width 6-9/16"

Height 7-25/32"

Swash Plate Bore 3/4" x 3/16" Keyway

Valve Type Polyamide Plastic

1 A 25 PSIG minimum inlet pressure is required.

HR2527A ELECTRIC HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI2000 PSI2750 PSI 34502.51.72.63.44.7
HORSEPOWER RATINGSThe rating shown are the power

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

HR2527A GAS HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI2000 PSI2750 PSI 34502.52.33.44.56.3

We recommend a 1.15 service factor

be specified when selecting an electric motor as the power source. To compute specific pump horse- power requirements, use the Follow- ing formula:

Electric HP = (GPM X PSI) / 1460 Gas HP = (GPM X PSI) / 1100

Page 4 of the Giant HR3025 user manual — RPM .....................................................................................................3450
Page 4 · click to enlarge
Page 4

Specifications Model HR3025

Axial Pump

Volume HR3030 3.0 GPM

Maximum Discharge Pressure 2500 PSI

Maximum Inlet Pressure Up to 90 PSIG1

RPM 3450

Plunger Diameter 16mm

Stroke 5.9mm (8.0 o angle)

Crankcase Oil Capacity 4.5 fl. oz.

Temperature of Pumped Fluids Up to 80 oF

Inlet Port 1 x 1/2" NPT

Discharge Ports 3/8" NPT

Shaft Rotation Clockwise

Weight 11.4 lbs.

Width 6-7/16"

Height 10-1/4"

Swash Plate Bore 3/4” x 3/16” Keyway

Valve Type Polyamide Plastic

1 A 25 PSIG minimum inlet pressure is required.

HR3025 ELECTRIC HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI2000 PSI2500 PSI 34503.02.13.14.15.1
HORSEPOWER RATINGSThe rating shown are the power

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

HR3025 GAS HORSEPOWER REQUIREMENTS RPMGPM1000 PSI1500 PSI2000 PSI2500 PSI 34503.02.74.15.56.8

We recommend a 1.15 service factor

be specified when selecting an electric motor as the power source. To compute specific pump horse- power requirements, use the Follow- ing formula:

Electric HP = (GPM X PSI) / 1460 Gas HP = (GPM X PSI) / 1100

Page 5 of the Giant HR3025 user manual — RPM .....................................................................................................3450
Page 5 · click to enlarge
Page 5

Specifications Model HR3030

Axial Pump

Volume HR3030 3.0 GPM

Maximum Discharge Pressure 3000 PSI

Maximum Inlet Pressure Up to 90 PSIG1

RPM 3450

Plunger Diameter 16mm

Stroke 5.9mm (8.0 o angle)

Crankcase Oil Capacity 4.5 fl. oz.

Temperature of Pumped Fluids Up to 80 oF

Inlet Port 1 x 1/2" NPT

Discharge Ports 3/8" NPT

Shaft Rotation Clockwise

Weight 11.4 lbs.

Width 6-7/16"

Height 10-1/4"

Swash Plate Bore 1"x3/16" Keyway

Valve Type Polyamide Plastic

1 A 25 PSIG minimum inlet pressure is required.

HR3030 ELECTRIC HORSEPOWER REQUIREMENTS RPMGPM1500 PSI2000 PSI2500 PSI3000 PSI 34503.03.14.15.16.2
HORSEPOWER RATINGSThe rating shown are the power

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

HR3030 GAS HORSEPOWER REQUIREMENTS RPMGPM1500 PSI2000 PSI2500 PSI3000 PSI 34503.04.15.56.88.2

We recommend a 1.15 service factor

be specified when selecting an electric motor as the power source. To compute specific pump horse- power requirements, use the Follow- ing formula:

Electric HP = (GPM X PSI) / 1460 Gas HP = (GPM X PSI) / 1100

Page 6 of the Giant HR3025 user manual — HR2527A/HR3025/HR3030 EXPLODED VIEW
Page 6 · click to enlarge
Page 6

HR2527A/HR3025/HR3030 EXPLODED VIEW

Giant HR3025 — HR2527A/HR3025/HR3030 EXPLODED VIEW diagram (page 6)
Fig. 3
Page 7 of the Giant HR3025 user manual — HR2527A/HR3025/HR3030 SERIES PARTS LIST
Page 7 · click to enlarge
Page 7

HR2527A/HR3025/HR3030 SERIES PARTS LIST

ITEM PART # DESCRIPTION QTY.

ITEM PART # DESCRIPTION QTY.

46 06423 Piston 1

1* 06311 Adapting Plate (HR2527A/HR3025) 1

1* 06403 Adapting Plate (HR3030) 1

47 07937 O-Ring 2

2 07881A Socket Head Cap Screw ¼” 8

48 12031-0002 Back-Up Ring 2

3 07344 O-Ring 1

49 06227 Ball, By Pass Valve 1

50 06324 Adjusting Plug 1

4 07805 Radial Shaft Seal 1

5** 06419 7.1o Piece Wobble Plate (HR2527A) 1

51 07917A Washer 1

5** 06402 8o Wobble Plate (HR3025/HR3030) 1

52 06608 Adjusting Spring 1

6 06393 Steel Shaft ¾” (HR2527A/HR3025) 1

54 06239 Guide Plug 1

56 12007 O-Ring 8

6 06401 Steel Shaft 1" (HR3030) 1

7 08089 Crankcase 1

58 07045 Handwheel 1

8A* 06300 Rear Bearing, Complete 1

59 06524 Adjusting Screw 1

8B** 06301 Front Bearing, Complete 1

62 12326 O-Ring 1

63 12325 Kick-Back Valve Cone 1

10 06319 Plunger 3

11 06318 Spring Disc Retainer 3

64 12328 Kick-Back Valve Spring 1

12 06291 Clip Ring 3

66 07935A By Pass Valve Seat 1

14 07873 Plunger Spring 3

67+ 06414 Mounting Flange "X" Style (HR2527) 1

69+ 07467 Bolt (HR2527) 4

15 06316 Oil Seal 3

16 06317 Spacer Ring 3

72 06224 Washer 3

18 07374 Valve Spring 6

75 23422A Thermal Valve 1

19 06295 Valve Cone (Discharge) 3

76 06306 Injector Retainer 1

77 12516-001 O-Ring Viton 1

19A 06267 Valve Cone (Inlet) 3

20 06315 V-Sleeve 3

78 23010-0100 Ball, 7/32” Dia. ss 1

22 06290 Pressure Ring 3

79 23009 Spring, Injector 1

28 06424 Manifold 1

80 06312 O-Ring 1

81 06339 Oriface, 2.1mm 1

34 07379 Manifold Plug 3

36 07913 O-Ring 1

84 12517 Hose Barb 1

37 06313 Suction Flange 1

87 07044 Locknut 1

38 07910A O-Ring, Flange 1

88 07046 Cover 1

89 08250 Sightglass w/gasket 1

39 06320 Stud Bolt 3

41 08083 Oil Fill Cap 1

90 07939 Nut 1

42 06273 Oil Drain Plug 1

91 07068 Locknut w/Nylon Insert 1

43 08192 Gasket 1

+ 09502 Gasoline Flange kit

* When ordering a 06311 please order 17021 which includes 06311, 07344, 07805, 06300 - HR2527A/HR3025 * When ordering a 06403, please order 17038 which includes 06403, 07344, 07805, 06300 - HR3030

** When ordering 06419, please order 17036, which includes 06419, 06393, & 06301 - HR2527A ** When ordering 06402, please order 17051, which includes 06402, 06393 & 06301 - HR3025 ** When ordering 06402, please order 17040, which includes 06402, 06401, & 6301 - HR3030

Page 8 of the Giant HR3025 user manual — GX and HR Pump Part Numbering System
Page 8 · click to enlarge
Page 8

HR2527A/HR3025/HR3030 Repair Kits

Unloader Repair Kit # 09235 Item Part # Description Qty. 36 07913 O-Ring 1 47 07937 O-Ring, Adjusting Screw 2 48 12031-0002 Teflon Back-Up Ring 2 49 06227 8mm Ball 1 56 12007 O-Ring 2 62 12326 O-Ring 1 66 07935A By Pass Seat 1

Plunger Packing Kit # 09465 Item Part # Description Qty. 22 06290 Pressure Ring 3 20 06315 V-Sleeve 3

Valve Assembly Kit # 09475 Item Part # Description Qty. 18 07374 Valve Spring 6 19A 06267 Guided P-Valve 3 19 06295 Discharge Valve Cone 3

Oil Seal Kit # 09468 Item Part # Description Qty. 15 06316 Plunger Oil Seal 3

HR2527A/HR3025/HR3030 SERIES TORQUE SPECIFICATIONS

Position Item# Description Torque Amount (ft.-lbs) 2 07881A Socket Head Cap Screw 1/4" 100in-lbs. 39 06320 Stud Bolt 360in-lbs.

GX and HR Pump Part Numbering System

GX or HR SeriesFlowPressure (in 100 psi increments)Injector SizeThremal Relief ValveWobble Plate Shaft Bore Vertical20=GPM25=2500 PSI1=2.1 mm1=1/2"1=3/4" Horizontal23=GPM2=1.8mm2=7/8" 25=GPM3=2.3mm3=1" 4=5/8” GX or HR2.525-111

For example, a GXV2525-112 is a GX pump that produces 2.5 GPM @ 2500 PSI, has a injector with a 2.1mm Oriface, 1/2" thermal relief valve and 7/8" wobble plate bore.

Page 9 of the Giant HR3025 user manual — MALFUNCTION
Page 9 · click to enlarge
Page 9

PUMP TROUBLE SHOOTING

MALFUNCTION

CAUSE

REMEDY

The Pressure and/or the Delivery Drops

Worn packing seals Broken valve spring Worn or Damaged nozzle Fouled discharge valve Fouled inlet strainer Worn or Damaged hose Worn or Plugged relief valve on pump Cavitation

Replace packing seals Replace spring Replace nozzle Clean valve assembly Clean strainer Repair/Replace hose Clean, Reset, and Replace worn parts Check suction lines on inlet of pump for restrictions

High humidity Worn seals

Reduce oil change interval Replace seals

Replace bearings, Refill crankcase oil with recommended lubricant Check inlet lines for restrictions and/or proper sizing

Rough/Pulsating Operation with Pressure Drop

Worn packing Inlet restriction

Replace packing Check system for stoppage, air leaks, correctly sized inlet plumb- ing to pump

Check inlet lines for restrictions and/or proper size

Pressure Drop at Gun

Re-size discharge plumbing to flow rate of pump

Worn plungers Worn packing/seals Excessive vacuum Inlet pressure too high

Replace plungers Adjust or Replace packing seals Reduce suction vacuum Reduce inlet pressure

Wrong Grade of oil Improper amount of oil in crankcase

Giant oil is recommended Adjust oil level to proper amount

Show 8 more labels / short text on this page
Water in crankcase · Noisy Operation · Worn bearings · Cavitation · Cavitation · Restricted discharge plumbing · Excessive Leakage · High Crankcase Temperature
Page 10 of the Giant HR3025 user manual — REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030
Page 10 · click to enlarge
Page 10

REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030

Giant HR3025 — REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030 diagram (page 10)
Fig. 4
Giant HR3025 — REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030 diagram (page 10)
Fig. 5
1. With a 19mm socket wrench, remove the three discharge valve plugs (34). Inspect the valve plug o-rings (56) for wear, and replace as necessary. Remove the valve spring (18) and valve cone (19) from the manifold (28). Inspect the parts for wear and replace as necessary.
2. With a 19mm crescent wrench, remove the adjusting screw assembly (50, 56, 47, and 59). Unscrew the adjusting screw (59) from the adjusting screw plug (50).
Giant HR3025 — REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030 diagram (page 10)
Fig. 6
Giant HR3025 — REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030 diagram (page 10)
Fig. 7
3. With a crescent wrench, remove the injector retainer (76).
4. Inspect the o-ring (36) for wear and replace as necessary. Remove the kickback valve spring (64), kickback valve cone (63), and the o-ring (62) from the manifold (28). Inspect and clean the siphon injector and ball clean parts for wear and replace as necessary.
Giant HR3025 — REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030 diagram (page 10)
Fig. 8
Giant HR3025 — REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030 diagram (page 10)
Fig. 9

49 51 52 59 47 56 58

5. Inspect the o-rings (56 and 47) for wear and replace as necessary. Remove the adjusting spring (52), washer (51) and by pass valve ball (49) from the manifold (28). Inspect the parts for wear and replace as necessary.
6. Next, remove the three manifold stud nuts (39) with a 17mm wrench. Remove the suction flange (37) and flange o-ring (38). Inspect the o-ring for wear and replace as necessary.
Page 11 of the Giant HR3025 user manual — Contact Giant Industries for service school information. Phone: (419) 531-4600
Page 11 · click to enlarge
Page 11

REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030

Giant HR3025 — REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030 diagram (page 11)
Fig. 10
Giant HR3025 — REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030 diagram (page 11)
Fig. 11

54 56 48 47 48 46 66

7. Tap the back of the manifold (28) with a rubber mallet to dislodge, and slide off the plungers (10). Take note of the position of the discharge port so as to place the port in the same position during reassembly.
8. With a 19mm socket wrench, remove the guide plug (54) and o-ring (56) from the manifold (28). Remove the piston (46), o-ring (47), and backup rings (48). Using a 7/32" Allen wrench, remove the bypass valve seat (66). Inspect the parts for wear and replace as necessary.
Giant HR3025 — REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030 diagram (page 11)
Fig. 12
Giant HR3025 — REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030 diagram (page 11)
Fig. 13

74 16 22 20 18 19A

9. Remove the valve cones (19A), valve springs (18), v-sleeves (20) and pressure rings (22). Inspect for wear and replace as necessary. Remove the spacer ring (16) and flinger (56) from the plungers (10).
10. If the crankcase oil seals (15) are to be replaced, they can be removed by prying loose with a small screwdriver. Take care not to make contact with the plunger (10) and pry out the oil seals from their housing.
11. Reassemble in reverse order. Fill the crankcase until the proper amount of oil (see specifications page 3). The pump is now ready for operation.

Contact Giant Industries for service school information. Phone: (419) 531-4600

Page 12 of the Giant HR3025 user manual — 3/01 HR2527A/HR3030.PM6
Page 12 · click to enlarge
Page 12

11.25” (HR3030)

HR2527A/HR3025/HR3030 SERIES DIMENSIONS

9.75” (HR2527A/HR3025)

Giant HR3025 — 11.25” (HR3030) diagram (page 12)
Fig. 14
Giant HR3025 — 11.25” (HR3030) diagram (page 12)
Fig. 15

6.44”

GIANT INDUSTRIES LIMITED WARRANTY

Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows:

1. For portable pressure washers and self-service car wash applications, the discharge manifolds are guaranteed for the life of the pump. Our other pump parts, used in portable pressure washers and in car wash applications, are warranted for five years from the date of shipment for all pumps used in NON-SALINE, clean water applications. 2. One (1) year from the date of shipment for all other Giant industrial and consumer pumps. 3. Six (6) months from the date of shipment for all rebuilt pumps. 4. Ninety (90) days from the date of shipment for all Giant accessories.

This warranty is limited to repair or replacement of pumps and accessories of which the manufacturer’s evaluation shows were defective at the time of shipment by the manufacturer. The following items are NOT covered or will void the warranty:

1. Defects caused by negligence or fault of the buyer or third party. 2. Normal wear and tear to standard wear parts. 3. Use of repair parts other than those manufactured or authorized by Giant. 4. Improper use of the product as a component part. 5. Changes or modifications made by the customer or third party. 6. The operation of pumps and or accessories exceeding the specifications set forth in the Operations Manuals provided by Giant Industries, Inc.

Liability under this warranty is on all non-wear parts and limited to the replacement or repair of those products returned freight prepaid to Giant Industries which are deemed to be defective due to workmanship or failure of material. A Returned Goods Authorization (R.G.A.) number and completed warranty evaluation form is required prior to the return to Giant Industries of all products under warranty consideration. Call (419)-531-4600 or fax (419)-531-6836 to obtain an R.G.A. number. A complete copy of our current RGA policy may be obtained from Giant Industries by written request.

Repair or replacement of defective products as provided is the sole and exclusive remedy provided hereunder and the MANUFACTURER SHALL NOT BE LIABLE FOR FURTHER LOSS, DAMAGES, OR EXPENSES, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES DIRECTLY OR INDIRECTLY ARISING FROM THE SALE OR USE OF THIS PRODUCT.

THE LIMITED WARRANTY SET FORTH HEREIN IS IN LIEU OF ALL OTHER WARRANTIES OR REPRESENTATION, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRAN- TIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ALL SUCH WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED BY THE MANUFACTURER.

GIANT INDUSTRIES, INC., 900 N. Westwood Ave., P.O. Box 3187, Toledo, Ohio 43607 PHONE (419) 531-4600 FAX (419) 531-6836, www.giantpumps.com Ó Copyright 2001 Giant Industries, Inc.

3/01 HR2527A/HR3030.PM6

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Giant HR3025

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Giant HR3025

Be the first to ask — other owners or our team will answer.

Original document

Giant HR3025 manual PDF

12 pages·348 KB·Water Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…