EN
Giant logo
Official user manual

Giant GP7255A

8 pages·123 KB·Water Pump·PDF·ENDEFRITNLJA
Giant GP7255A
Table of Contents 12 sections Triplex Ceramic Plunger Pump Manual Models GP7150A, GP7155A, GP7255A · Updated 03/06 · INSTALLATION INSTRUCTIONS · Specifications Model GP7155A, GP7255A · … ShowHide
Page 1 of the Giant GP7255A user manual — Updated 03/06
Page 1 · click to enlarge
Page 1

Triplex Ceramic Plunger Pump Manual Models GP7150A, GP7155A, GP7255A

Giant GP7255A — Triplex Ceramic Plunger Pump Manual Models GP7150A, GP7155A, GP7255A diagram (page 1)
Fig. 1 · Triplex Ceramic Plunger Pump Manual Models GP7150A,…
Giant GP7255A — Triplex Ceramic Plunger Pump Manual Models GP7150A, GP7155A, GP7255A diagram (page 1)
Fig. 2 · Triplex Ceramic Plunger Pump Manual Models GP7150A,…

Contents: Installation Instructions GP7155A/GP7255A: page 2 Pump Specifications: page 3 Parts List/Exploded View: pages 4-5 Pump Specifications GP7150A: page 6 Recommended Spare Parts List: page 7 Repair Instructions: page 7 Dimensions: back page Warranty Information back page

Updated 03/06

Page 2 of the Giant GP7255A user manual — INSTALLATION INSTRUCTIONS
Page 2 · click to enlarge
Page 2

INSTALLATION INSTRUCTIONS

Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance.

reduce system pulsation. Dampeners can also reduce the severity of pressure spikes that occur in systems using a shut-off gun. A dampener must be positioned downstream from the un- loader.

5. Crankshaft rotation on Giant Industries, Inc. pumps should be made in the direction designated by the arrows on the pump crankcase. Reverse rotation may be safely achieved by following a few guidelines available upon request from Giant Industries, Inc. Required horsepower for system operation can be obtained from the charts on pages 3 & 6.
1. The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication.
2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joints. If pumps are to be operated at temperatures in excess of 140
6. Before beginning operation of your pumping system, remember: Check that the crankcase and seal areas have been properly lubricated per recommended schedules. Do not run the pump dry for extended periods of time. Cavitation will result in severe damage. Always remember to check that all plumbing valves are open and that pumped media can flow freely to the inlet of the pump.

o F, it is impor- tant to insure a positive head to the pump to prevent cavitation.

3. The discharge plumbing from the pump should be properly sized to the flow rate to prevent line pressure loss to the work area. It is essential to provide a safety bypass valve between the pump and the work area to protect the pump from pressure spikes in the event of a blockage or the use of a shutoff gun.

Finally, remember that high pres sure operation in a pump system has many advantages. But, ifit is used carelessly and without regard to its potential hazard, it can cause serious injury.

4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further
2. Pump operation must not exceed rated pressure, volume, or RPM. A pressure relief device must be installed in the discharge of the system.
1. Prior to initial operation, add oil to crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL. Use Giant Recommended Oil (p/n 01154), which is equivalent to SAE 85-90W Industrial Grear Lube. Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.
3. Acids, alkalines, or abrasive fluids cannot be pumped unless approval in writing is obtained before operation from Giant Industries, Inc.
4. Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures.
Page 3 of the Giant GP7255A user manual — (GPH X PSI) / 1450 = HP
Page 3 · click to enlarge
Page 3

Specifications Model GP7155A, GP7255A

U.S Metric Volume 65.8 GPM 250 LPM Discharge Pressure 1500 PSI 100 Bar Speed 2000 PSI 138 Bar Inlet Pressure Up to 700 RPM Plunger Diameter 2.17” 55mm Plunger Stroke 2.05” 52mm Crankshaft Diameter 1.89” 48mm Key Width 0.55” 14mm Crankshaft Mounting Either side Shaft Rotation Top of pulley towards manifold Max.Temperature of Pumped Fluids 140 oF 60 oC Inlet Ports (2) 2-1/2" NPT Discharge Ports (2) 1-1/4" NPT Weight 374 lbs 170 kg Crankcase Oil Capacity 1.6 Gal 6.0 liters Fluid End Material GP7155A Bronze Fluid End Material GP7255A Nickle Plated Spheroidical Cast Iron Mechanical Effecency @ 700 RPM 0.83 Volumetric Effecency @ 700 RPM 0.96

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

PULLEY INFORMATION Pulley selection and pump speed are based on a 1725 RPM motor and "B" section belts. When selecting desired GPM, allow for a ±5% tolerance on pumps output due to variations in pulleys, belts and motors among manufacturers. 1. Select GPM required, then select appropriate motor and pump pulley from the same line. 2. The desired pressure is achieved by selecting the correct nozzle size that corresponds with the pump GPM.

HORSEPOWER INFORMATION Horsepower ratings shown are the power require- ments for the pump. Gas engine power outputs must be approximately twice the pump power require- ments shown above. We recommend that a 1.1 service factor be specified when selecting an electric motor as the power source. To compute specific pump horsepower requirements, use the following formula:

(GPH X PSI) / 1450 = HP

GP7155A, GP7255A PULLEY SELECTION & HORSEPOWER REQUIREMENTS PUMP PULLEYMOTOR PULLEYRPMGPM800 PSI1000 PSI1300 PSI1500 PSI2000 PSI 12.759.0047945.025.732.141.848.264.3 12.759.7553149.928.535.646.353.571.3 12.7510.7558555.031.439.351.158.978.6 12.7511.7063860.034.342.955.764.385.7 12.7512.7570065.837.647.061.170.594.0
Page 4 of the Giant GP7255A user manual — Exploded View - GP7150A/GP7155A/GP7255A
Page 4 · click to enlarge
Page 4

Exploded View - GP7150A/GP7155A/GP7255A

Giant GP7255A — Exploded View - GP7150A/GP7155A/GP7255A diagram (page 4)
Fig. 3 · Exploded View - GP7150A/GP7155A/GP7255A
Page 5 of the Giant GP7255A user manual — Spare Parts List - GP7150A/GP7155A/GP7255A
Page 5 · click to enlarge
Page 5

Spare Parts List - GP7150A/GP7155A/GP7255A

ITEM PART DESCRIPTION QTY. 1 07600 Crankcase 1 2 13000 Oil Filler Plug Assembly 1 4 07601 Crankcase Cover 1 5 07602 Gasket, Crankcase Cover 1 8 07603 Oil Dip Stick 1 9 01009 O-Ring, Dip Stick 1 10 13133 Hexagon Screw 12 11 13134 Spring Washer 12 12 07109 Drain Plug 3 13 07182 Gasket, Drain Plug 2 14 07607 Bearing Cover 2 15 07608 Radial Shaft Seal 2 16 07184 O-Ring 2 20 07610 Taper Roller Bearing 2 20A 07611 Fitting Disc (Shim) 1-5 21 07612 Shaft Protector 1 22 13405 Crankshaft 1 23 07614 Key 1 24 13182 Connecting Rod Assy. 3 25 13183 Crosshead Assy. 3 28 13184 Crosshead Pin 3 30 07619 Cover Plate 1 30A 07225-0100 Hexagon Screw 8 30B 13136 Grommet 4 30C 08280 Washer 8 30D 13154 Cover Plate 1 31 07623 Eye Bolt 1 32 07624 Radial Shaft Seal 3 32A 07625 Shaft Seal 3 33 07626 Seal Retainer 3 33A 07627 O-Ring 3 33B 07628 Circlip 3 33C 07249 Fitting Disc 3 34 13137 Oil Scraper 3 36 07706 Plunger Pipe Assy. (GP7155A/GP7255A) (36 A-D) 3 36 07630 Plunger Pipe Assy. (36A-D) 3 36A 07667 Plunger Connection 3 36B 07793 Plunger Pipe (50mm) 3 36B 07666 Plunger Pipe (55mm) (GP7155A/GP7255A) 3 36C 07664 Tension Screw 3 36D 07665 Copper Ring 3 38 13155 Seal Case (GP7155A/GP7255A) 3

ITEM PART DESCRIPTION QTY. 38 07794 Seal Case (GP7150A) 3 38A 13156 O-Ring 3 38B 07721 O-Ring (GP7155A/GP7255A) 3 38B 06258 O-Ring (GP7150A) 3 38C 07635 Support Ring (GP7150A Only) 3 39 13157 Seal Sleeve (GP7155A/GP7255A) 3 39 07795 Seal Sleeve (GP7150A) 3 39A 07723 Compact Ring (GP7155A/GP7255A) 3 39A 07796 Compact Ring (GP7150A) 3 40* 07797 Support Disc (GP7155A/GP7255A) 3 41 13158 O-Ring (GP7155A/GP7255A) 3 41 07636 Tension Spring (GP7150A) 3 42 07711 V-Sleeve (GP7155A/GP7255A) 6 42 07638 V-Sleeve (GP7150A) 6 43 07712 Pressure Ring (GP7155A/GP7255A) 3 43 07639 Pressure Ring (GP7150A) 3 44 07637 Support Ring (GP7150A only) 3 49 13159 Stud Bolt 8 49A 13160 Hex Nut 8 50 07790 Valve Casing (GP7155A) 1 50 07791 Valve Casing (GP7255A) 1 50 06628 Valve Casing (GP7150A) 1 50A 13162 Cylinder Stud 2 51 08288 Valve Assembly 6 51A 08281 Spring Tension Cap 6 51B 08282 Valve Spring Guide 6 51C 07732-0100 Valve Spring 6 51D 13164 Valve Plate 6 51E 08283 Valve Seat 6 51F 07653 O-Ring 6 51G 13166 Support Ring 6 51H 07266 O-Ring 6 56 13167 Valve Adaptor 3 56A 07658 O-Ring 6 56B 07635 Support Ring 6 56C 13166 Support Ring 3 56D 07653 O-Ring 3 57 13173 Tension Spring 6 58 13170 Plug 3 59A 07661 Copper Ring 1 60 12251 Plug, 1-1/4” NPT 1 61 12252 Plug, 2-1/2” NPT 1 66 13362 Disc For Crankshaft 1 67 13358 Hexagon Screw 1 * This item may be removed to add a third v-sleeve.

Plunger Packing Kit # 09526 - GP7150A Item Part # Description Qty. 38A 13156 O-Ring 3 38B 06258 O-Ring 3 39A 07796 Compact Ring 3 41 07636 O-Ring 3 42 07638 V-Sleeve 6

Valve Kit # 09606* Item Part # Description Qty. 51B 08282 Valve Spring Guide 1 51C 07732-0100 Valve Spring 1 51D 13164 Valve Plate 1 51E 08283 Valve Seat 1 51F 07653 O-Ring 2 51G 13166 Support Ring 2 51H 07266 O-Ring 2 56A 07658 O-Ring 2 56B 07635 Support Ring 2 56C 13166 Support Ring 1 56D 07653 O-Ring 1

Plunger Packing Kit # 9220 - GP7155A & GP7255A Item Part # Description Qty. 38A 13156 O-Ring 3 38B 07721 O-Ring 3 39A 07223 Compact Ring 3 41 13158 O-Ring 3 42 07711 V-Sleeve 6

* Note: When ordering a valve kit for a pump produced prior to 11/03, order kit #09222, which replaces part 08281 with p/n 13163. Kit 09222 does not require p/n 08282.

Oil Seal Kit - # 09221 Item Part # Description Qty. 32 07624 Radial Shaft Seal 3 32A 07625 Shaft Seal 3 33A 07627 O-Ring 3

Page 6 of the Giant GP7255A user manual — (GPH X PSI) / 1450 = HP
Page 6 · click to enlarge
Page 6

Specifications Model GP7150A

U.S Metric Volume 54.5 GPM 206 LPM Discharge Pressure 1900 PSI 131 Bar Speed 700 RPM Inlet Pressure 140 PSI 10 Bar Plunger Diameter 1.97” 50mm Plunger Stroke 1.89” 48mm Crankshaft Diameter 1.89” 48mm Key Width 0.55” 14mm Crankshaft Mounting Either side Shaft Rotation Top of pulley towards manifold Max.Temperature of Pumped Fluids 140 oF 60 oC Inlet Ports (2) 2-1/2" NPT Discharge Ports (2) 1-1/4" NPT Weight 374 lbs 170 kg Crankcase Oil Capacity 1.6 Gal 6.0 liters Fluid End Material Bronze Mechanical Effecency @ 700 RPM 0.83 Volumetric Effecency @ 700 RPM 0.96

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

PULLEY INFORMATION Pulley selection and pump speed are based on a 1725 RPM motor and "B" section belts. When selecting desired GPM, allow for a ±5% tolerance on pumps output due to variations in pulleys, belts and motors among manufacturers. 1. Select GPM required, then select appropriate motor and pump pulley from the same line. 2. The desired pressure is achieved by selecting the correct nozzle size that corresponds with the pump GPM.

HORSEPOWER INFORMATION Horsepower ratings shown are the power require- ments for the pump. Gas engine power outputs must be approximately twice the pump power require- ments shown above. We recommend that a 1.1 service factor be specified when selecting an electric motor as the power source. To compute specific pump horsepower requirements, use the following formula:

(GPH X PSI) / 1450 = HP

GP7150A PULLEY SELECTION & HORSEPOWER REQUIREMENTS PUMP PULLEYMOTOR PULLEYRPMGPM800 PSI1000 PSI1300 PSI1500 PSI1900 PSI 12.755.7530023.413.416.721.725.131.8 12.757.5040031.217.822.329.033.442.3 12.759.2550038.922.227.836.141.752.8 12.7511.0060046.726.733.443.450.063.4 12.7512.7570054.531.138.950.658.474.0
Page 7 of the Giant GP7255A user manual — Reassemble in revers order: Regulate axial bearing clearance minimum 0.1mm, maximum 0.15-by
Page 7 · click to enlarge
Page 7

GP7150A, GP7155A, GP7255A REPAIR INSTRUCTIONS

TO CHECK VALVES Lossen plugs (58), take out tension spring (57) and then remove the complete valve (51) with either a valve tool or an M16 hexagon screw. Remove valve adapter (56) and tension spring (57) with pull-out tool size 5. There is an O-ring (51G) under both the suction and the discharge valve each of which can be removed with a bent piece of wire.To disassemble valve hit the top of the valve plate (C) carefully with a bolt and press the valve seat (A) out of the spacer pipe (E). Check sealing surfaces and replace worn parts. Check O-rings and support rings.Tighten plugs (58) to 107 ft. lbs.

TO CHECK SEALS AND PLUNGER PIPE Loosen nuts (49A) and remove pump head. Separate plunger connection (36A) from crosshead (25) by means of two open-end wrenches (size 22 and 27). Pull seal sleeves (39) out of their fittings in the crankcase. Take seal case (38) out of seal sleeve (39). Examine plunger parts (36A-36D), seals (42,39A) and O-rings. When replacing plunger pipe (36B), tighten tension screws (36C) to 30 ft. lbs. Replace worn parts; grease seals with Silicone before installing.

CAUTION: Don't loosen the 3 plunger connections (36A) before the valve casing has been removed otherwise the tension screw (36C) could hit against the spacer pipe (51E) when the pump is being turned. Seal life can be increased if the pretensioning allows for a little leakage. This assists lubrication and keeps the seals cool. It is therefore not necessary to replace seals before the leakage becomes too heavy and causes output and operating pressure to drop.

MOUNTING VALVE CASING Check O-rings on seal case (38). Clean surfaces of seal sleeves in gear box and sealing surfaces of valve casing. Push valve casing carefully on O-rings of seal case and centering studs (50A). Tighten nuts (49A) to 103 ft. lbs.

TO DISASSEMBLE GEAR Take out plunger and seal sleeves as described above. Drain oil. After removing the circleclip ring (33B), lever out seal retainer (33) with a screw driver. Check seals (32, 32A, 33A) and surfaces of crosshead. Remove crankcase cover (4). Loosen inner hexagon screws on the connecting rods (24) and push con rod halves as far into the crosshead guide as possible.

Reassemble in revers order: Regulate axial bearing clearance minimum 0.1mm, maximum 0.15-by

Preventative Maintenance Check-List & Recommended Spare Part List Check Daily Weekly 50hr Every Every Every 500 hr 1500 hr 3000hrs Oil Level / Quality X Oil Leaks X Water Leaks X Belts, Pulley X Plumbing X Recommended Spare Part Oil Change (p/n 01154) X X Plunger Packing Kits(1 kit/Pump) See page 5 for kit list Oil Seal Kit ( 1 kit/Pump See page 5 for kit list) Valve Assembly Kit ( 1 kit/pump) See page 5 for kit list

Page 8 of the Giant GP7255A user manual — 03/06 GP7150A, GP7155A, GP7255A.PM6
Page 8 · click to enlarge
Page 8

GP7150A, GP7155A, GP7255A SERIES DIMENSIONS - INCHES (mm)

Giant GP7255A — GP7150A, GP7155A, GP7255A SERIES DIMENSIONS - INCHES (mm) diagram (page 8)
Fig. 4 · GP7150A, GP7155A, GP7255A SERIES DIMENSIONS - INCHES…

GIANT INDUSTRIES LIMITED WARRANTY

Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows:

1. For portable pressure washers and self-service car wash applications, the discharge manifolds will never fail, period. If they ever fail, we will replace them free of charge. Our other pump parts, used in portable pressure washers and in car wash applications, are warranted for five years from the dateof shipment for all pumps used in NON-SALINE, clean water applications. 2. One (1) year from the date of shipment for all other Giant industrial and consumer pumps. 3. Six (6) months from the date of shipment for all rebuilt pumps. 4. Ninety (90) days from the date of shipment for all Giant accessories.

This warranty is limited to repair or replacement of pumps and accessories of which the manufacturer’s evaluation shows were defective at the time of shipment by the manufacturer. The following items are NOT covered or will void the warranty:

1. Defects caused by negligence or fault of the buyer or third party. 2. Normal wear and tear to standard wear parts. 3. Use of repair parts other than those manufactured or authorized by Giant. 4. Improper use of the product as a component part. 5. Changes or modifications made by the customer or third party. 6. The operation of pumps and or accessories exceeding the specifications set forth in the Operations Manuals provided by Giant Industries, Inc.

Liability under this warranty is on all non-wear parts and limited to the replacement or repair of those products returned freight prepaid to Giant Industries which are deemed to be defective due to workmanship or failure of material. A Returned Goods Authorization (R.G.A.) number and completed warranty evaluation form is required prior to the return to Giant Industries of all products under warranty consideration. Call (419)-531-4600 or fax (419)-531-6836 to obtain an R.G.A. number.

Repair or replacement of defective products as provided is the sole and exclusive remedy provided hereunder and the MANUFACTURER SHALL NOT BE LIABLE FOR FURTHER LOSS, DAMAGES, OR EXPENSES, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES DIRECTLY OR INDIRECTLY ARISING FROM THE SALE OR USE OF THIS PRODUCT.

THE LIMITED WARRANTY SET FORTH HEREIN IS IN LIEU OF ALL OTHER WARRANTIES OR REPRESENTA- TION, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ALL SUCH WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED BY THE MANUFACTURER.

GIANT INDUSTRIES, INC. 900 N. Westwood Ave. P.O. Box 3187 Toledo, Ohio 43607 (419) 531-4600 FAX (419) 531-6836 Copyright 2006 Giant Industries, Inc.

03/06 GP7150A, GP7155A, GP7255A.PM6

Ask about the Giant GP7255A

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Giant GP7255A

Be the first to ask — other owners or our team will answer.

Original document

Giant GP7255A manual PDF

8 pages·123 KB·Water Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…