Table of Contents 59 sections GENEVA HOT BEVERAGE MERCHANDISER · OPERATOR MANUAL · MODEL 3205 FRESH BREW 3206 FREEZE DRIED · JUN 2008 4214803 • C · … ShowHide
Page 1 of the Geneva Lab 3206 user manual — JUN 2008 4214803 • C
Page 1 · click to enlarge
Page 1

GENEVA HOT BEVERAGE MERCHANDISER

Geneva Lab 3206 — GENEVA HOT BEVERAGE MERCHANDISER diagram (page 1)
Fig. 1

OPERATOR MANUAL

MODEL 3205 FRESH BREW 3206 FREEZE DRIED

JUN 2008 4214803 • C

Page 2 of the Geneva Lab 3206 user manual — GENEVA HOT BEVERAGE MERCHANDISER
Page 2 · click to enlarge
Page 2
Page 2 of the Geneva Lab 3206 user manual — GENEVA HOT BEVERAGE MERCHANDISER
Page 3 of the Geneva Lab 3206 user manual — TEMPERATURE : 46°F (8°C) - 90°F (32°C)
Page 3 · click to enlarge
Page 3

INTRODUCTION

1. The information contained in this service manual is applicable to the Hot Beverage Merchandiser. The Hot Beverage Merchandiser line consists of two types of coin-operated, microprocessor controlled, Hot Beverage Merchandisers that dispense a range of hot beverages in response to keypad selections.
2. Two versions of each model are available:

Freeze-dried (INST) - Freeze-dried Coffee and Tea

Fresh Brew (SFB) - Fresh Brew Coffee

3. This manual uses the SFB version as the basis for examples. Where significant differences between versions exist this will be highlighted in the main body of the document. Due to customer requirements, however, some features may vary from those described, e.g. extras fitted, variations in programming etc.
4. Cups from a cup drop mechanism are dispensed to contain the beverages.
5. Selections are made on a 12 button keypad and an LCD display panel indicates status and beverage selection information.
6. The status of the machine may be monitored and the configuration altered by accessing a menu of program options using both internal and external keypads. A number of sub-options are included under each option, the settings of which can be altered.
7. A feature of the Hot Beverage Merchandiser is the mobile dispense head which moves to a parked position away from the cup port after each beverage is vended, preventing the possibility of any residue from the previous delivery cycle dripping into the next one.
8. Hot Beverage Merchandiser machines require a single-phase 120V electrical supply from a 12A outlet, and a cold water supply. These services connect to the machine through the rear of the cabinet.
9. Maintenance of the coffee machine must be undertaken only by personnel who are authorized and suitably qualified.
10. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. The manufacturer reserves the right to modify the designs or specifications of such products at any time without notice.

SPECIFICATIONS

DIMENSIONS

CUP CAPACITY

HEIGHT72 inches (1830 mm)
QUANTITYUp to 400 (12 oz) cups
DEPTH26.8 inches (680 mm)
SIZES7 oz, 8 ¼ oz, 9 oz, 10 oz & 12 oz
WIDTH27.6 inches (700 mm)

SHIPPING WEIGHT

OPERATING ENVIRONMENT

360 lbs (163 kg) – Fresh Brew version

LOCATION: For indoor use only.

ELECTRICAL

SOUND LEVELProduces less than 70dBA during normal operation

120 Volts, 60 Hz, 9.2 Amps nominal

240 Volts, 50 Hz, 13 Amps

TEMPERATURE : 46°F (8°C) - 90°F (32°C)

  • G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3 1
Page 4 of the Geneva Lab 3206 user manual — CABINET REAR
Page 4 · click to enlarge
Page 4

SAFETY WARNINGS

  • DISCONNECT / UNPLUG POWER TO THE MACHINE BEFORE SERVICING . Lethal voltages are exposed when any panel inside the cabinet is removed if power is supplied to the on/off switch.
  • Installation and maintenance of the Hot Beverage Merchandiser is to be undertaken only by trained personnel who are fully aware of the dangers involved and who have taken adequate precautions.
  • The Hot Beverage Merchandiser must be grounded (earthed). Do not tamper, modify or remove the ground pin from the power plug. Should the power cord or plug become damaged, a trained person from an approved service agent must perform the replacement using only factory approved parts. Do not ground (earth) the machine to the water supply pipe.
  • Keep clear of the Brewer Unit when it is operating .
  • The Hot Beverage Merchandiser is a heavy item. Ensure that sufficient personnel are available for lifting and transporting the machine. Use proper lifting procedures and equipment.
  • The water in the heater tank and the tank itself are hot enough to scald or burn even some time after the machine has been switched off. The water tank must be drained, filled with cold water and drained again before any attempt is made to handle it or any of its associated parts.
  • The Controller Board is fitted with a lithium battery. Abuse of this type of battery can lead to overheating, venting, explosion, release of potentially hazardous materials and spontaneous ignition. The lithium battery must not be charged by, or connected to, any other source of power. The battery must not be short-circuited or forced to discharge its stored energy. The battery must not be subjected to physical damage or overheating. ONLY the Trained Technician should attempt controller board replacement!
  • Care must be taken to protect the Hot Beverage Merchandiser from frost. Do not attempt to operate the machine if it becomes frozen. Contact the nearest service agent immediately. Do not restore the machine to operation until it has been checked and approved for use by the service agent.
  • Due to the risk of being scalded by hot beverages, young children, the aged and the infirm should not be allowed to operate the Hot Beverage Merchandiser unsupervised.

GENERAL DESCRIPTION

Opening the merchandiser door via the key operated lock allows access to its internal components. Equipment inside the Hot Beverage Merchandiser is arranged in two sections: front and rear. When the merchandiser door is open the Operator has immediate access to those items which he or she will be controlling or adjusting (Ingredient Canisters, Cup Compartment, Coin Mechanism, Waste Buckets, etc.). The remaining equipment (Water Heater, Valves, Electrical and electronics components, etc), access to which is limited to the Trained Technician, are located behind the panel at the rear of the cabinet.

CABINET FRONT

The Cup Drop Assembly, Coin Mechanism, Controller Board and Cup Station are fitted to the rear of the door. The Customer’s keypad is on the door front panel.

Ingredient canisters are located on a shelf within the cabinet above the mixing area. An extractor fan removes excessive moisture from the mixing systems, helping assure that the systems function properly. The moving dispense head keeps residue from previous dispensing cycles from dripping into the current dispensing cycle.

Level sensor probes assure that the waste buckets will not overflow. When a level-sensor probe is activated the water supply is shut off and the machine is rendered inoperable until the waste container is emptied.

CABINET REAR

Access to the components and equipment in the rear section of the cabinet (behind the rear panel) is limited to the Trained Technician.

  • 2 G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3
Page 5 of the Geneva Lab 3206 user manual — MACHINE PARTS
Page 5 · click to enlarge
Page 5

Water for beverages travels through the inlet valve and into the water heater tank located at the top and back of the cabinet. Solenoid dispensing valves direct the heated water to the appropriate mixing bowl. Excessively hot water flowing from the tank activates a high temperature cut-out switch. When activated the cut-out switch cuts off the electrical supply to the heater in the tank. The cut-out must then be reset to reactivate the heater

Level probes located in the cabinet door and waste container allows the unit’s control system to monitor the liquid level in the waste containers and prevent overflow.

MACHINE PARTS

Coffee Brewer Unit Cup Storage Compartment

Geneva Lab 3206 — MACHINE PARTS diagram (page 5)
Fig. 2

Stainless Steel Canister Shelf

Whipper Chamber & Station

Geneva Lab 3206 — MACHINE PARTS diagram (page 5)
Fig. 3

Cup Station Liquid Waste Bucket

Coffee Grounds Waste Bucket

Safety Probe Liquid Waste Bucket Cash Box Drain Tray Cup Station

  • G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3 3
Show 10 more labels / short text on this page
Ingredient Canisters · Splash Guard · Internal Keypad · Rinse Hose · Door Lock · Dispense Arm · Cup Delivery Chute · Water Filter · Upper Rinse Funnel · `
Page 6 of the Geneva Lab 3206 user manual — LEVELING
Page 6 · click to enlarge
Page 6

INSTALLATION

1. Servicing personnel must be familiar with the SAFETY WARNINGS listed in this manual and the Safety Manual (P/N 4206816) before undertaking any installation or maintenance procedure on the Hot Beverage Merchandiser. Any procedure which is found to be impractical, inadequate or inaccurate should be reported to the Management for further investigation.
2. The information given in this section covers installation and maintenance procedures for the Hot Beverage Merchandiser. Only authorized personnel who have knowledge or experience with the equipment, and using only the manufacturer’s approved parts should carry out these procedures.
3. The requirements of proper hygiene in respect of food products must be ensured at every level of contact with the Hot Beverage Merchandiser and the ingredients associated with it.

SET-UP REQUIREMENTS

ELECTRICAL SUPPLY

  • 110V, 60Hz, 12A fused
  • 240V, 50Hz, 13A fused

The electrical outlet and supply circuit must be dedicated and isolated before connecting power to the machine. The electrical outlet must be within 6 ft (2 m) of the machine. Preferably, the switched outlet should be located behind the machine to prevent accidental damage or misuse.

WATER SUPPLY

The main water supply must have 15-116 psi pressure. The water outlet must have a shutoff valve so that the water supply to the merchandiser may be turned off during servicing. The water outlet should be located behind the machine to prevent misuse.

Geneva Lab 3206 — WATER SUPPLY diagram (page 6)
Fig. 4

LOCATION

The Hot Beverage Merchandiser must be located close to the appropriate electrical and water outlets.

There must be a minimum of 4 inches (100mm) clearance between the rear of the cabinet and the wall to allow adequate ventilation. See Figure 4a.

If placing in a corner location, there must be at least 16 inches (406mm) of space to the right hand wall to allow the door to open properly.

Figure 4a. Distance From Wall

LEVELING

The Hot Beverage Merchandiser must be level for proper operation. Using a level as a guide turn the machine’s leg levelers as needed until all levelers are touching the floor. If it is properly leveled, the merchandiser should not “rock” or “teeter” on any of the levelers.

  • 4 G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3
Page 7 of the Geneva Lab 3206 user manual — CHECKLIST
Page 7 · click to enlarge
Page 7

When the machine is level, the door can be opened to any position and not swing either way. Try the door at various open positions before deciding that the machine is leveled.

Geneva Lab 3206 — CONNECT WATER diagram (page 7)
Fig. 5

CONNECT WATER

Before connecting the hose to the machine, flush the water supply system via the shutoff valve to remove any impurities which may have accumulated in the supply pipe or water hose.

Geneva Lab 3206 — CONNECT WATER diagram (page 7)
Fig. 6

The merchandiser’s water inlet - a standard ¼” NPT female water hose connector - is located on the back of the machine. Remove the plastic protective cap. See Figure 4b. There is also a 3/8” Flare Fitting supplied inside the waste bucket if this is preferred.

Connect the water supply hose to machine water inlet and ensure that all fittings are tight. Turn on the water supply at the shutoff valve and check for leaks both outside and inside of the machine.

Figure 4b. Power Cord & Water Inlet

CONNECT ELECTRICAL

Plug the Hot Beverage Merchandiser power cord into a 110V, 60Hz, 12A (240V, 50Hz, 13A) switch supply

socket. With the plug fitted to the socket, ensure that the cable is not stretched, distorted or hampered by any object.

CHECKLIST

It is essential that the technician responsible for installing and commissioning the machine ensures the following:

1. All electrical and water supplies are correctly and safely connected and that the water heater overflow pipe is not trapped or pinched (remove canisters to access and remove rear panel to check status of overflow pipe.)
2. All covers, panels and access doors are in place and secured, and the machine is in a SAFE condition.
3. The Operator is familiar with the SAFETY PRECAUTIONS for the machine.
4. The Operator appreciates the importance of hygiene and regular cleaning of the merchandiser.

With water and electricity sources connected to the machine, check the water heater operation as follows:

1. Press merchandiser on/off switch (upper left side of interior back wall) to the ON position. Water will flow into the water tank. Wait approx. 1 minute and the water will shut off (safety feature). Then turn the power switch OFF, wait a few seconds and turn the power switch back ON. Water will continue to fill the tank. When water reaches the probe level, the heater will turn on as indicated by the heater indicator light (to the right of the on/off switch). There should be no water overflow into the waste basket.

2. Ensure that the waste level probe is positioned in the waste basket.
3. Press the merchandiser on/off switch to the OFF position.
  • G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3 5
Page 8 of the Geneva Lab 3206 user manual — FILL PRODUCT CANISTERS
Page 8 · click to enlarge
Page 8

FILL PRODUCT CANISTERS

DO NOT USE LIQUID INGREDIENTS.

Figure 5a. Canister LineupFigure 5b. Product Chute Figure 5c. Locator Peg Figure 5d. Motor Shaft Figure 5e. Canister Lid Figure 5f. Fill Canister
Geneva Lab 3206 — FILL PRODUCT CANISTERS diagram (page 8)
Fig. 7
Geneva Lab 3206 — FILL PRODUCT CANISTERS diagram (page 8)
Fig. 8
Geneva Lab 3206 — FILL PRODUCT CANISTERS diagram (page 8)
Fig. 9
Geneva Lab 3206 — FILL PRODUCT CANISTERS diagram (page 8)
Fig. 10
Geneva Lab 3206 — FILL PRODUCT CANISTERS diagram (page 8)
Fig. 11
Geneva Lab 3206 — FILL PRODUCT CANISTERS diagram (page 8)
Fig. 12
Geneva Lab 3206 — FILL PRODUCT CANISTERS diagram (page 8)
Fig. 13
  • 6 G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3
Page 9 of the Geneva Lab 3206 user manual — CHANGE MENU SELECTION LABELS
Page 9 · click to enlarge
Page 9
13. Rotate the product chute so that it points down (dispense position) to the whipper bowl. See Figure 5b .
Geneva Lab 3206 — CHANGE MENU SELECTION LABELS diagram (page 9)
Fig. 14
14. Repeat above steps for other canisters.

Figure 5g. Do Not Pack

CHANGE MENU SELECTION LABELS

Figure 6a. Bottom Wing NutFigure 6b. Inside Wing NutsFigure 6c. Remove Top Sign Front Figure 6d. Menu Selection Label
Geneva Lab 3206 — CHANGE MENU SELECTION LABELS diagram (page 9)
Fig. 15
Geneva Lab 3206 — CHANGE MENU SELECTION LABELS diagram (page 9)
Fig. 16
Geneva Lab 3206 — CHANGE MENU SELECTION LABELS diagram (page 9)
Fig. 17
Geneva Lab 3206 — CHANGE MENU SELECTION LABELS diagram (page 9)
Fig. 18
6. Insert the new menu selection label through the slots. Check the front of the Top Sign Front to make sure that the menu selection labels are correctly aligned.
7. Insert the right edge of the Top Sign Front into the slot of the right side Retaining Strip. See Figure 6c .
8. Slip the left side Retaining Strip over the left edge of the Top Sign Front. Push the Retaining Strip back into place. See Figure 6c . ( To accommodate the rounded front design, carefully bow the left edge of the assembly to the right until you are able to press the three retaining screws back into position .)
9. Reinstall and tighten the wing nuts saved from steps 1 and 2. See Figure 6a and Figure 6b .

beverage type or content.

  • G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3 7
Page 10 of the Geneva Lab 3206 user manual — ADJUSTING CUP RING SETTING
Page 10 · click to enlarge
Page 10

ADJUSTING CUP RING SETTING

The cup mechanism has been factory adjusted for an 8.25 oz. paper hot beverage cup. Follow the instructions below to adjust the cup (diameter) size if necessary.

Figure 8a. Cup Compartment LatchFigure 8b. Cup Diameter Adjustment (PRENOV2007) Figure 8c. Cup Diameter Adjustment (POST-NOV2007) Figure 8d. Cup Position In Mechanism
Geneva Lab 3206 — ADJUSTING CUP RING SETTING diagram (page 10)
Fig. 19
Geneva Lab 3206 — ADJUSTING CUP RING SETTING diagram (page 10)
Fig. 20
Geneva Lab 3206 — ADJUSTING CUP RING SETTING diagram (page 10)
Fig. 21
Geneva Lab 3206 — ADJUSTING CUP RING SETTING diagram (page 10)
Fig. 22
  • 8 G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3
Page 11 of the Geneva Lab 3206 user manual — SET PRICE FOR SINGLE CUP VOLUME (LARGE)
Page 11 · click to enlarge
Page 11

SET PRICE FOR SINGLE CUP VOLUME (LARGE)

The following procedure sets the price for the three (3) item types: filled Regular Cup, Cup Only and a filled Large Cup. For additional information regarding Set Pricing Modes and Change Prices, please refer to the programming section of this manual.

STEPDISPLAY 1. On internal keypad, press PROGPLEASE ENTER ACCESS CODE 2. On external keypad, enter code 1111SET PRICING MODE 3. Press 2 or 8.CHANGE PRICES 4. Press 0.LARGE PRICES 5. Press 2 or 8 to scroll to SET ALL PRICESSET ALL PRICES 6. Press0LARGE PRICES 7. Press 0 to enter a new pricePrice=$0.00 8. Press 4 (move curser left) or 6 (move cursor right), press 2 (increase value) or press 8 (decrease value). 9. Press 0 to accept the price for ALL LARGE PRICES 10. Press # (ESCAPE)LARGE PRICES 11. Press 2 or 8 to scroll to other price settings for LARGE PRICE NOTE: This is to set the prices for individual drinks different from the value set in STEP 9LARGE PRICE 12. Press 0 to select the drink selection price to changeCOFFEE Price= 000.00 13. Press 4 (move curser left) or 6 (move cursor right), press 2 (increase value) or press 8 (decrease value). 14. Press 0 to accept the price 15. Repeat steps 11 to 14 to set prices for any other drinks 16. Press # (ESCAPE)LARGE PRICES 17. Press 2 or 8 to scroll to other selection price settingsCUP PRICE 18. Press 0 to accept CUP PRICE Note: This is DISCOUNTED VALUE for using your own cupCUP Price=$0.00 19. Press 4 (move curser left) or 6 (move cursor right), press 2 (increase value) or press 8 (decrease value). 21. Press 0 to accept the DISCOUNTED VALUE 22. Press # three times to exit the programming mode.SELECT DRINK TO SHOW PRICE
  • G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3 9
Page 12 of the Geneva Lab 3206 user manual — SET PRICE FOR DUAL CUP VOLUMES (LARGE AND REGULAR )
Page 12 · click to enlarge
Page 12

SET PRICE FOR DUAL CUP VOLUMES (LARGE AND REGULAR )

Dual Menu Label set is required to set this option. Order P/N 4214600 Dual Drink/Cup Menu Label set.

STEPDISPLAY 1. On internal keypad, press PROGPLEASE ENTER ACCESS CODE 2. On external keypad, enter code 1111SET PRICING MODE 3. Press 2 or 8.CHANGE PRICES 4. Press 0.LARGE PRICES 5. Press 2 or 8 to scroll to SET ALL PRICESSET ALL PRICES 6. Press 0LARGE PRICES 7. Press 0 to enter a new pricePrice= $000.00 8. Press 4 (move curser left) or 6 (move cursor right), press 2 (increase value) or press 8 (decrease value). 9. Press 0 to accept the price for ALL LARGE PRICES 10. Press 2 or 8 to scroll to REGULAR PRICESREGULAR PRICES 11. Press 0 to enter a new pricePrice= $000.00 12. Press 4 (move curser left) or 6 (move cursor right), press 2 (increase value) or press 8 (decrease value). 13. Press 0 to accept the price for ALL REGULAR PRICES 14. Press # (ESCAPE)LARGE PRICES 15. Press 0 to select the drink selection price to change NOTE: This is to set the prices for individual drinks different from the value set in STEP 9 for LARGE DRINKSCOFFEE Price= $000.00 16. Press 4 (move curser left) or 6 (move cursor right), press 2 (increase value) or press 8 (decrease value). 17. Press 0 to accept the price 18. Press 2 or 8 to scroll to REGULAR PRICESREGULAR PRICES 19. Press 0 to select the drink selection price to change NOTE: This is to set the prices for individual drinks different from the value set in STEP 13 for REGULAR DRINKSCOFFEE Price= $000.00 20. Press 4 (move curser left) or 6 (move cursor right), press 2 (increase value) or press 8 (decrease value). 21. Press 0 to accept the price 22. Press 2 or 8 to scroll to other selection price settingsCUP PRICE 23. Press 0 to accept CUP PRICE Note: This is DISCOUNTED VALUE for using your own cupCUP Price= $000.00 24. Press 4 (move curser left) or 6 (move cursor right), press 2 (increase value) or press 8 (decrease value). 21. Press 0 to accept the DISCOUNTED VALUE 22. Press # three times to exit the programming mode.SELECT DRINK TO SHOW PRICE
  • 10 G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3
Page 13 of the Geneva Lab 3206 user manual — STEP DISPLAY
Page 13 · click to enlarge
Page 13

CUP SIZE ADJUSTMENT

IMPORTANT: Your Hot Beverage machine has been factory-set for use of 8.25 oz. PAPER hot beverage cups. The machine can also be set up to use 7, 9, 10, or 12 oz. cups. If you are not using 8.25 oz. cups, you must readjust the machine before use. This is a 2-part procedure. Both Cup Size Adjustment and Adjusting Cup Dispenser Opening must be accomplished.

STEP DISPLAY

1. On internal keypad, press PROG PLEASE ENTER ACCESS CODE
2. On external keypad, enter code 1111 SET PRICING MODE
3. Using 2 or 8 Scroll to CONFIGURE MC CONFIG MC
4. Press 0 GENERAL SETTINGS
5. Using 2 or 8 Scroll to SETCUP SIZE CUP SIZE
6. Press 0 XX oz
7. Using 2 or 8 scroll to desired size 8.25 oz
8. Press 0 to confirm selection 8.25 oz
9. Press # to exit programming mode SELECT DRINK TO SHOW PRICE
  • G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3 11
Page 14 of the Geneva Lab 3206 user manual — FILL CUP COMPARTMENT
Page 14 · click to enlarge
Page 14

FILL CUP COMPARTMENT

Geneva Lab 3206 — FILL CUP COMPARTMENT diagram (page 14)
Fig. 23
Geneva Lab 3206 — FILL CUP COMPARTMENT diagram (page 14)
Fig. 24
Geneva Lab 3206 — FILL CUP COMPARTMENT diagram (page 14)
Fig. 25
Geneva Lab 3206 — FILL CUP COMPARTMENT diagram (page 14)
Fig. 26
Geneva Lab 3206 — FILL CUP COMPARTMENT diagram (page 14)
Fig. 27

Figure 9a. Cup Spirals

Figure 9b. Cup Stacks

Figure 9c. Keypad Cup Test

Geneva Lab 3206 — FILL CUP COMPARTMENT diagram (page 14)
Fig. 28
1. Check that the top and bottom spirals are aligned the same and have room for three (3) stacks of cups. See Figure 9a .
2. The cup compartment can have a total of five (5) cup stacks. Load the compartment with cups starting with the first stack in the cup dispenser mechanism followed by three (3) additional cup stacks. See Figure 9b . The cupstacks must be aligned with the top and bottom spirals. Add the fifth cup stack directly in front of the fourth cup stack and place it tight against the left side wall of the compartment.
3. Close and latch the cup compartment door.

Figure 9d. Counterweight

4. Find the internal keypad on the left side of the door (as viewed from the rear of the door). Press the square marked “ CUP TEST ”. See Figure 9c .
Geneva Lab 3206 — FILL CUP COMPARTMENT diagram (page 14)
Fig. 29

4a. The cup should be dispensed via the stainless steel cup chute and land squarely on the platform of the delivery compartment. See Figure 9e.

4b. If the cup gets stuck at the counter- balance wire, loosen the counterweight and slide it up to lessen the weight against the cup. See Figure 9d. Repeat step 4.

Figure 9e. Delivery Compartment

  • 12 G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3
Page 15 of the Geneva Lab 3206 user manual — STEP DISPLAY
Page 15 · click to enlarge
Page 15

INGREDIENT VOLUME ADJUSTMENT

Follow the instructions below to change the ingredient volume settings.

STEP DISPLAY

1. On internal keypad, press PROG . PLEASE ENTER ACCESS CODE
2. On external keypad, enter code 3333 (or current Manager code). INGREDIENT TIMES
3. Press 0. DRINKS OF SIZE REGULAR
4. Press 0 . The first product selection is displayed SET TIMINGS FOR COFFEE

5 To scroll to a different product selection press 2 or 8 repeatedly until the desired product name is displayed.

6. Press 0 . The first ingredient setting is displayed.
7. To scroll to a different ingredient, press 2 or 8 repeatedly. OP: Sugar Mod 0%
8. Press 0. You are now ready to change the ingredient percentage value.
9. Press 4 (move cursor left) or 6 (move cursor right), or press 2 (increase) or 8 (decrease).
OPSugar Mod Value=5%
10. Press 0 (enter) to accept the revised setting. OP: Sugar Mod 5%
11. To modify another ingredient in this product selection, repeat steps 7 through 10 . To modify another product selection, press # and repeat steps 5 through 10 .
12. Press # three (3) times to exit the programming mode. SELECT DRINK FROM MENU
  • G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3 13
Page 16 of the Geneva Lab 3206 user manual — FLUSH MIXING BOWLS
Page 16 · click to enlarge
Page 16

FLUSH HEATER TANK, BOWL & BREWER

Geneva Lab 3206 — FLUSH HEATER TANK, BOWL & BREWER diagram (page 16)
Fig. 30
Geneva Lab 3206 — FLUSH HEATER TANK, BOWL & BREWER diagram (page 16)
Fig. 31

INSTALL WASTE CONTAINERS

1. Place a trash liner (13 Gal) inside the large waste container. Place the waste container under the heater tank overflow tube and the brewer. 2. Place the small bucket under the cup dispensing tubes. See Figure 10a
Geneva Lab 3206 — INSTALL WASTE CONTAINERS diagram (page 16)
Fig. 32
Geneva Lab 3206 — INSTALL WASTE CONTAINERS diagram (page 16)
Fig. 33

FLUSHING THE MACHINE

Ensure that the Mixing Bowls are flushed daily and each time after refilling the canisters.

FLUSH MIXING BOWLS

1. Open Machine as instructed and ensure machine is switched ON .
  • 14 G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3
Page 17 of the Geneva Lab 3206 user manual — MERCHANDISER RECORD
Page 17 · click to enlarge
Page 17
2. Press FLUSH button. See Figure 10b. The Machine will flush all the whippe r and mixing bowls with clean hot water.
3. Repeat as necessary.
4. Once flushing has ceased, the machine will be ready for use.

FLUSH COFFEE BREWER

1. Open Machine as instructed and ensure machine is switched ON .
2. Ensure that hands and loose clothing are clear of the brewer.
3. Press the BREWER FLUSH button. See Figure 10b. The Machine will flush the brewer(s) with clean hot water.
4. Repeat if necessary.
5. Once flushing has ceased, the machine will be ready for use.

DRIP CATCHER

Place a cup on the Drip Catcher Holder to prevent any remaining liquid in the base of the cup station from dripping onto the floor when the door is opened during servicing.

Geneva Lab 3206 — DRIP CATCHER diagram (page 17)
Fig. 34
1. The Drip Catcher is located on the inside of the door below the Cup Station.
2. Place a 7 oz or 8.25 oz cup on the Drip Catcher Cup Holder. See Figure 12a .
3. IMPORTANT : Place the Overflow Bucket Sensor inside the drain bucket before closing the door. See Figure 12b .

Figure 12a. Drip Catcher

Geneva Lab 3206 — DRIP CATCHER diagram (page 17)
Fig. 35

Figure 12b. Waste Bucket Sensor

MERCHANDISER RECORD

A schedule sheet for cleaning and maintenance should be kept up to date at all times. A schedule sheet clip has been provided for your convenience. It can be found beneath the internal keypad. The space is large enough for an 8.5x11 sheet.

  • G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3 15
Page 18 of the Geneva Lab 3206 user manual — INTERIOR:
Page 18 · click to enlarge
Page 18

CLEANING PROCEDURES

Care should be taken when cleaning the interior of the merchandiser as high temperatures may be present on components and liquids.

A high standard of personal hygiene is essential for a coffee vending machine operative. Hair & clothing must be neat & clean. Hands & finger nails must be washed thoroughly before any work commences in the drink preparation areas. Jewellery should be kept to a minimum. An operative who is suffering from cuts, sores or any form of illness must inform their supervisor before commencing any work in the drink preparation area.

All cleaning tasks should be undertaken with the machine Switched OFF by means of the switch located in the back left had corner of the cabinet above the ingredient canisters.

Disposable non-linting clothes (‘contact’, ‘non-contact’ & ‘external’) Clean disposable gloves Plastic scraper Spray bottle Cleaning bucket

EXTERIOR:

Cleaning agent for removing stubborn stains Glass cleaner or similar for cleaning the plastic screens

INTERIOR:

A sanitizer for cleaning & disinfecting

Some Do’s & Don’ts:

  • Do not use metal scrapers
  • Do not put any of the machine internal parts on the floor
  • Do not take water for cleaning from a toilet area
  • Always wear protective gloves when using cleaning agents
  • Always use the correct cleaning agent for the application & follow the manufacturer’s instructions
  • Separate clothes should be used to clean specific areas of the machine parts. These clothes should be kept separated in re-sealable bags The ‘ CONTACT ’ cloth should be used on areas of the machine that come into contact with drink preparation:

Whipper Station Parts Delivery Tubes

Coffee Brewer Unit Parts Delivery nozzles

Dispense Arm Ingredient Canister Shelf

Ingredient Canisters Cup Compartment

Cup Chute Cup Station

  • 16 G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3

Hygiene · Safety · Recommended items required

Page 19 of the Geneva Lab 3206 user manual — CLEANING PROCEDURES
Page 19 · click to enlarge
Page 19

The ‘NON-CONTACT’ cloth should be used on other internal areas of the machine:

Liquid Waste Bucket Coffee Grounds Waste Bucket

Cabinet Floor Coin Changer & Validator

Overflow Pipe All other internal surfaces

The ‘EXTERNAL’ cloth should be used on all external surfaces with exception of the cup station

  • After removing the ingredient canisters in order to fill them, always wipe down/clean the shelf
  • Half fill the cleaning vessel/bucket with clean hot water form the rinse hose and add the recommended amount of sanitizer
  • Remove all mixing bowls/chambers, delivery tubes & nozzles and place in cleaning vessel/bucket
  • Dismantle coffee brewer filter platform & chamber and place in cleaning vessel/bucket (see below for detailed instructions)
  • Remove all chutes from the ingredient canister outlets and place in cleaning vessel/bucket
  • Wipe down/clean internal surfaces of cabinet
  • Clean/sanitize the parts in the cleaning vessel/bucket, rinse thoroughly with hot water, and refit ( ensure the canister chutes are dry! )
  • Remove the drain tray/grill from the underside of the cup station and place in cleaning vessel/bucket
  • Remove the upper rinse funnel and place in cleaning vessel/bucket
  • Spray some sanitizer on the cup chute and cup counter balance and clean surfaces
  • Spray some sanitizer on the internal surfaces of the cup station and clean
  • Clean & refit the rinse funnel & drain tray/grill
  • Wipe down/clean internal surfaces of door
  • Remove all ingredient canisters and remove the front stainless steel, place in cleaning vessel/bucket
  • Remove the stainless steel cup chute by slackening the 2 fixing screws and lifting off keyhole slots, place in cleaning vessel/bucket
  • Wipe down/clean the surface under the ingredient shelf
  • Clean and refit parts.
  • Refit the ingredient canisters
  • G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3 17

Daily/Weekly Routine · Monthly Routine

Page 20 of the Geneva Lab 3206 user manual — DISMANTLING COFFEE BREWER UNIT
Page 20 · click to enlarge
Page 20

DISMANTLING COFFEE BREWER UNIT

(Fresh Brew Model only)

  • Open the door of the machine and switch machine OFF using Main Switch
  • Turn the Coffee Canister Dispense Chute upward to prevent ingredients being spilled onto the floor of the machine.
  • Figure 13a - Remove the Coffee Brewer outlet spout.
Geneva Lab 3206 — DISMANTLING COFFEE BREWER UNIT diagram (page 20)
Fig. 36
  • Figure 13b - Remove the Brewer splashguard by lifting the cover up and toward you.
Geneva Lab 3206 — DISMANTLING COFFEE BREWER UNIT diagram (page 20)
Fig. 37
  • Figure 13c & Figure 13d - Lift and release both of the carriage locking catches.
Geneva Lab 3206 — DISMANTLING COFFEE BREWER UNIT diagram (page 20)
Fig. 38
Geneva Lab 3206 — DISMANTLING COFFEE BREWER UNIT diagram (page 20)
Fig. 39
  • 18 G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3
Page 21 of the Geneva Lab 3206 user manual — DISMANTLING COFFEE BREWER UNIT
Page 21 · click to enlarge
Page 21
  • Figure 13e - Remove the filter carriage by sliding it towards you.
Geneva Lab 3206 — DISMANTLING COFFEE BREWER UNIT diagram (page 21)
Fig. 40
  • Figure 13f - Unclip/Detach the Sealing Rod Connector by pulling towards you.
Geneva Lab 3206 — DISMANTLING COFFEE BREWER UNIT diagram (page 21)
Fig. 41

When re-assembling do not forget to reconnect the Sealing Rod

  • Figure 13g - Holding the Brewing Chamber as shown pull it gently towards you to remove it
Geneva Lab 3206 — DISMANTLING COFFEE BREWER UNIT diagram (page 21)
Fig. 42
  • Figure 13h - Lift off he Steam Extractor Hood
Geneva Lab 3206 — DISMANTLING COFFEE BREWER UNIT diagram (page 21)
Fig. 43

When replacing the Steam Extractor Hood ensure it is located behind the release catch and that it is sat-down properly as shown.

  • Use de-staining product to clean the Brewer, cylinder, steam trap and carriage assembly . Then rinse all parts thoroughly with clean water.
  • G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3 19
Page 22 of the Geneva Lab 3206 user manual — FILTER BELT REMOVAL & REPLACEMENT
Page 22 · click to enlarge
Page 22

FILTER BELT REMOVAL & REPLACEMENT

  • Figure 14a - First note the Tension Locking Bar in the ‘tensioned’ position
Geneva Lab 3206 — FILTER BELT REMOVAL & REPLACEMENT diagram (page 22)
Fig. 44
  • Figure 14b - Hold the carriage in your hand as shown, using your fingers release the tension on the filter belt by pulling back the tension arm in the direction indicated by the arrow, hold whilst moving to the next step
Geneva Lab 3206 — FILTER BELT REMOVAL & REPLACEMENT diagram (page 22)
Fig. 45
  • Figure 14c - Push the Red release handle forward and rotate in the direction of the BIG arrow, when the spindle is in the upright position as shown by the small arrow, pull the red handle back to lock in the ‘relaxed’ position
Geneva Lab 3206 — FILTER BELT REMOVAL & REPLACEMENT diagram (page 22)
Fig. 46
  • Figure 14d - The filter belt can now be removed as shown IMPORTANT:
Geneva Lab 3206 — FILTER BELT REMOVAL & REPLACEMENT diagram (page 22)
Fig. 47

I. The Coffee Filter Belt can be identified by its BLUE colored stitching thread (part # 4215265.001).

II. When fitting the new belt, ensure the belt is passed under the scraper plate indicated by the arrow

  • 20 G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3
Page 23 of the Geneva Lab 3206 user manual — REFITTING THE COFFEEE BREWER
Page 23 · click to enlarge
Page 23

REFITTING THE COFFEEE BREWER

  • Open the door of the machine and switch machine off using the main switch.
  • Fit the Steam Extractor Hood (Fig 13h) back onto the brewer chamber, and refit the unit to the machine.
  • Re-attach the sealing rod (Fig 13f).
  • Refit the carriage assembly (Fig 13e).
  • Use the locking catches (Fig’s 13c & 13d) to lock the carriage in place
  • Refit the splashguard (Fig 13b).
  • Refit the outlet elbow (Fig 13a).
  • Re-align the ingredient chutes into the brewer chamber.
  • Ensure that hands and loose clothing are clear of the brewer(s).
  • Switch machine back ON.
  • Close and lock the machine.
  • Once machine has reset, make a test of at least one coffee.
  • G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3 21
Page 24 of the Geneva Lab 3206 user manual — INSERT FLOAT
Page 24 · click to enlarge
Page 24

INTERNAL KEYPAD FUNCTIONS

Geneva Lab 3206 — INTERNAL KEYPAD FUNCTIONS diagram (page 24)
Fig. 48
Geneva Lab 3206 — INTERNAL KEYPAD FUNCTIONS diagram (page 24)
Fig. 49
Geneva Lab 3206 — INTERNAL KEYPAD FUNCTIONS diagram (page 24)
Fig. 50

The internal keypad is used to carry out a number of frequently required machine functions without entering Program mode.

In most cases a single press of the key initiates the function associated with each button. If a further key press is necessary to end the action it will be the ESC (escape) key.

The functions available from the internal keypad are:

a) ADVANCE COFFEE BREWER - If a coffee brewer is fitted, pressing this key one time will force the brewer unit to index to its next position in the cycle. The purpose of this function is to allow the brewer to be locked prior to a flush cycle so that cleaning agents can be added if desired.

b) MDB MECH DISPENSE COIN - This key provides a method of emptying the change tubes of an MDB coin mechanism. On pressing the key the external display will change to:

EMPTY TUBE $0.05

Ç , È ENTER OR ESC

The currency value shown will be that of the lower value coin tube in the mechanism. The function of the EXTERNAL keys will change as described in Section 3 to allow actions to be performed on either the internal or external keypad. Pressing ENTER will dispense a coin from the selected tube. Pressing Ç or È selects the next/previous coin tube. Pressing the ESC (escape) key ends the process.

c) MDB MECH FILL TUBES - If an MDB coin mechanism is fitted this function allows the change tubes to be filled. On pressing the key the external display will change to:

INSERT FLOAT

$0.00

  • 22 G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3
Page 25 of the Geneva Lab 3206 user manual — INTERNAL KEYPAD FUNCTIONS
Page 25 · click to enlarge
Page 25

As coins are inserted the value displayed will reflect the total value of the money inserted. Pressing ESC (escape) will cause the machine to return to normal operation and zero the credit. (Water tank must be heated to spec temperature before this command will function.)

d) BREWER FLUSH – (Fresh Brew model only.) Pressing this key initiates a flush cycle of all fresh brew units fitted to the merchandiser simultaneously.

e) PROG – Pressing this key activates the code entry sequence required to access the protected levels of the machine control programs. See Programming section

f) CUP TEST – Dispenses a cup via the cup drop mechanism. The cup spiral will not index unless a selection is made or a Cup Test performed.

g) DRINK TEST - Allows the next selection to be taken as a free vend.

h) COUNTERS - Pressing the COUNTERS key places the machine in manual audit mode. Audit data is accessed via a series of menus. The chart below shows the menu headings in bold text and the key presses required to navigate the menu are shown in italics. While in this mode the functions of the external keypad change to allow counter information to be accessed from the external (customer) keypad.

  • G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3 23
Page 26 of the Geneva Lab 3206 user manual — KEY FUNCTION
Page 26 · click to enlarge
Page 26

USER KEYPAD

When using SERVICE or COUNTERS mode the user keypad is used to navigate through the display menus, the functions are as follows:

Geneva Lab 3206 — USER KEYPAD diagram (page 26)
Fig. 51
Geneva Lab 3206 — USER KEYPAD diagram (page 26)
Fig. 52

KEY FUNCTION

Ç Move UP a list of menu options or increment a number.

È Move DOWN a list of menu options or decrement a number.

Å Move the cursor LEFT.

Æ Move the cursor RIGHT.

ESC ESCAPE - move to previous menu option or reject values entered.

ENTER ENTER the menu option displayed or accept the changes made.

  • 24 G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3
Page 27 of the Geneva Lab 3206 user manual — VIEWING COUNTER & EVENT RECORDS
Page 27 · click to enlarge
Page 27

TAKING A TEST VEND

Press the DRINK TEST key on the internal keypad once and then make a drink selection on the external keypad.

If more than one test vend is required, repeat the above procedure.

VIEWING COUNTER & EVENT RECORDS

Press the COUNTERS key on the internal keypad and using a combination of the display and the user keypad to navigate (see USER KEYPAD above), the following records can be viewed:

Heading Menu’s List:

  • DRINKS COUNTERS: The total number of each primary drink selection
  • TOTAL VEND COUNT: The grand total of all drinks vended (includes those vends with use of ‘own’ cup)
  • VENDED CUP COUNT: The number of cups vended
  • INGREDIENT COUNTERS: The weight in grams of each primary ingredient
  • EVENT LOG: A diagnostic log of events, the description, time and date are recorded
  • FINANCIAL AUDIT: A range of sub-menus giving monetary values

Available Sub-menu’s:

  • DRINKS COUNTERS Upon pressing ENTER scroll down/up the list of each primary drink selection
  • TOTAL VEND COUNT Upon pressing ENTER the grand total is displayed
  • VENDED CUP COUNT Upon pressing ENTER the total number of cups dispensed is displayed
  • INGREDIENT COUNTERS Upon pressing ENTER scroll down/up the list of each primary ingredient throw weight (in grams): Note: This needs to be set-up in SERVICE MODE to function.
  • EVENT LOG Upon pressing ENTER scroll down/up the list recorded events for diagnostic purposes (see table below or more details)
  • FINANCIAL AUDIT Upon pressing ENTER the following sub-menus are available: PERMANENT COUNTERS – Giving PAID, TEST & FREE values TUBE CONTENTS – Each change tube value can be viewed RESETTABLE COUNTERS – Giving PAID, TEST & FREE values
  • G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3 25
Page 28 of the Geneva Lab 3206 user manual — NOTES:
Page 28 · click to enlarge
Page 28

DIAGNOSTIC LOG

Displayed Message Explanation of Condition

KEY STUCK A key on the user keypad has been closed continuously for >15 seconds

WATER LEAKAGE The hot inlet valve has had to be switched on > 30 times since the last vend was taken

NO CUPS Comes into force after 2 unsuccessful attempts to drop a cup

ELECTRONICA Internal serial communication failure between the control board and the RIO board

IO CONFIG ERR. Board has not been initialized using the ENG LINK

WASTE TRAY FULL Either the Liquid or Coffee ground waste bucket is full of water

HEATER INHIBITED The heater tank has not filled within the 3.5 minute time limit

PLACE OWN CUP Sold-out of cups

FILLING BOILER Comes into force 15 seconds after starting to fill the heater tank with water. Indication of a slow rate of fill

C BREWER FAULT Brewer unit is not cycling correctly – a motor or cycle-switch fault

NEW FILTER REQD Filter belt warning (if activated) – comes into force after air pressure seen to be present after 7 seconds

FILTER BROKEN Brewer Fault – comes into force after air pressure has seen to be present after 20 seconds during a vend

DOOR FAULT Cup door mechanism is not cycling correctly - a motor or cycle- switch fault

NOTES:

1. The event log will only record events that persist for two or more consecutive event log checks. Event log checks take place once every 60s, so in the worst case scenario an event may have to be in force for almost 120s before it is recorded. 2) The event log does not handle concurrent events. If two (or more) fault conditions are active, only the first occurrence will be recorded.
  • 26 G E N E V A - H O T B E V E R A G E M E R C H A N D I S E R
  • 3 2 0 5
  • 3 2 0 6
  • 4 2 1 4 8 0 3
Page 29 of the Geneva Lab 3206 user manual — DIAGNOSTIC LOG
Page 29 · click to enlarge
Page 29
Page 29 of the Geneva Lab 3206 user manual — DIAGNOSTIC LOG
Page 30 of the Geneva Lab 3206 user manual — 4214803C.DOC
Page 30 · click to enlarge
Page 30

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.

165 North 10th Street Waukee, Iowa 50263 United States of America

USA & Canada International

Email vendnet@vendnetusa.com

Web Site www.vendnetusa.com

4214803C.DOC

Show 4 more labels / short text on this page
VendNet™ · Service (800) 833-4411 · (515) 274-3641 · Parts (888) 259-9965
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Geneva Lab 3206

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Geneva Lab 3206

Be the first to ask — other owners or our team will answer.

Original document

Geneva Lab 3206 manual PDF

30 pages·2.6 MB·Camcorder·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…