Standby Power Rating
Model QT070 (Aluminum - Bisque) - 70 kW 60 Hz Model QT080 (Aluminum - Bisque) - 80 kW 60 Hz Model QT100 (Aluminum - Bisque) - 100 kW 60 Hz Model QT130 (Aluminum - Bisque) - 130 kW 60 Hz Model QT150 (Aluminum - Bisque) - 150 kW 60 Hz

Meets EPA Emission Regulations 70, 100, 130 & 150 kW meet CA/MA emissions requirement with optional catalyst 80 kW not for sale in CA/MA
¡ INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance.
¡ SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%.
¡ SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.
¡ GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.


ENGINE SPECIFICATIONS: 80 kW
ENGINE LUBRICATION SYSTEM
Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is rated at 150 °C rise at 25 °C ambient All models fully prototyped tested
(All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271)

For Btu content, multiply ft3/hr x 2520 (LP) or ft3/hr x 1000 (NG).
For megajoule content, multiple m³/hr x 93.89 (LP) or m³/hr x 37.26 (NG).
Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes.
STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice.

70 kW 80 kW 100 kW 130 kW 150 kW

Flow at rated power (cfm/cmm) 205/5.8 250/7.1 262/7.4 336/9.5 410/11.6
*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.
Rated Synchronous rpm 1800 3600 2300 2970 3600
Temperature Deration 3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F Altitude Deration (70,100,130 & 150) 1% for every 100 m above 183 m or 3% for every 1000 ft above 600 ft Altitude Deration (80 kW) 1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft
2-Line Plain Text LCD Display Simple user interface for ease of operation. Mode Switch: Auto Automatic Start on Utility failure. 7 day exerciser
Off Stops unit. Power is removed. Control and charger still operate. Manual Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds Standard Engine Start Sequence Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration) Engine Warm-up 5 sec Engine Cool-Down 1 min Starter Lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Automatic Low Oil Pressure Shutdown Standard Overspeed Shutdown Standard, 72 Hz High Temperature Shutdown Standard Overcrank Protection Standard Safety Fused Standard Failure to Transfer Protection Standard Low Battery Protection Standard 50 Event Run Log Standard Future Set Capable Exerciser Standard Incorrect Wiring Protection Standard Internal Fault Protection Standard Common External Fault Capability Standard Governor Failure Protection Standard









©2013 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0199370SBY-B Printed in U.S.A. 07/30/13