EN
Generac logo
Official user manual

Generac 1654-0

32 pages·2 MB·Portable Generator·PDF·ENDEFRITNLJA
Generac 1654-0
Table of Contents 41 sections Owner’s Manual / Manual del Propietario · EQUIPMENT · DANGER · WARNING · … ShowHide
Page 1 of the Generac 1654-0 user manual — Owner’s Manual / Manual del Propietario
Page 1 · click to enlarge
Page 1
Generac 1654-0 — Owner’s Manual / Manual del Propietario diagram (page 1)
Fig. 1 · Owner’s Manual / Manual del Propietario

Owner’s Manual / Manual del Propietario

Parts Included* / Piezas Incluidas* Table of Contents / Tabla de Contenidos

  • Generator / Generador
  • Wheel Kit / Juego de Llantas
  • Locking 30 Amp Plug / Tapone de Fijación
  • Engine Oil / Aceite para Motor
  • Owner's Manual / Manual del Propietario
  • Engine Manual / Manual del Motor *If any parts are missing or damaged, call 1-800-270-1408. *Si alguna de las partes no está presente o está dañada, llame 1-800-270-1408.

Safety Rules / Reglas De Seguridad 2-3 / 20-21 Assembly / Ensamblaje 4-5 / 22-23 Know Your Generator / Conozca Su Generador 6 / 24 Operation / Funcionamiento 7-9 / 25-27 Product Specifications / Especificaciones Del Producto 10 / 28 Maintenance / Mantenimiento 10 / 28 Storage / Almacenamiento 11 / 29 Troubleshooting / Diagnosticos De Averías 12 / 30 Schematic / Esquemático 14 Wiring Diagram / Digrama Eléctrico 15 Replacement Parts / Piezas De Recambio 16-19 Notes / Notas 13 Garantia 31 Warranty Last Page

Questions? Help is just a moment away! Preguntas? La ayuda es justa un momento lejos! Call: Generac Generator Helpline - 1-800-270-1408 M-F 8-5 CT Llamada: Generador Helpline De Generac - 1-800-270-1408 M-F 8-5 CT Web: www.generac-portables.com or www.briggsandstratton.com

Model No. 1654-0 (5,500 Watt AC Generator) Manual No. 189828GS Revision 1 (02/05/2002)

Page 2 of the Generac 1654-0 user manual — WHEN TRANSPORTING OR REPAIRING EQUIPMENT
Page 2 · click to enlarge
Page 2
Generac 1654-0 — EQUIPMENT diagram (page 2)
Fig. 2

EQUIPMENT

DANGER

DESCRIPTION Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved. This generator is an engine–driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliances, tools and motor loads.The generator’s revolving field is driven at about 3,600 rpm by a single-cylinder engine.

Running generator gives off carbon monoxide, an ordorless, colorless, poison gas. Breathing carbon monoxide will cause nausea, fainting or death.

  • Operate generator ONLY outdoors.
  • Keep at least 2 feet of clearance on all sides of generator for adaquate ventilation.
  • Do not operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

Every effort has been made to ensure that information in this manual is accurate and current. However, Generac reserves the right to change, alter or otherwise improve the product and this document at any time without prior notice. The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency. For warranty information refer to the engine owner’s manual.

WARNING

Gasoline and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.

WARNING

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

WHEN ADDING FUEL

  • Turn generator OFF and let it cool at least 2 minutes before removing gas cap. Loosen cap slowly to relieve pressure in tank.

SAFETY RULES

  • Fill fuel tank outdoors.
  • Do not overfill tank.Allow space for fuel expansion.

The safety alert symbol ( ) is used with a signal word (DANGER, CAUTION,WARNING), a pictorial and/or a safety message to alert you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury. WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. CAUTION, when used without the alert symbol, indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.

  • Keep gasoline away from sparks, open flames, pilot lights, heat, and other ignition sources.
  • Do not light a cigarette or smoke.

WHEN OPERATING EQUIPMENT

  • Do not tip engine or equipment at angle which causes gasoline to spill.

WHEN TRANSPORTING OR REPAIRING EQUIPMENT

  • Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.
  • Disconnect spark plug wire.

WHEN STORING GASOLINE OR EQUIPMENT WITH FUEL IN TANK

  • Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite gasoline vapors.
Page 3 of the Generac 1654-0 user manual — CAUTION
Page 3 · click to enlarge
Page 3
Generac 1654-0 — CAUTION diagram (page 3)
Fig. 3

WARNING

WARNING

Generator produces powerful voltage. Failure to properly ground generator can result in electrocution. Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C). Severe burns can occur on contact.

  • Do not touch hot surfaces.
  • Allow equipment to cool before touching.
  • When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.
  • National Electric Code requires generator to be properly grounded to an approved earth ground. Call an electrician for local grounding requirements.
  • Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.
  • Do not touch bare wires or receptacles.
  • Do not use generator with electrical cords which are worn, frayed, bare or otherwise damaged.
  • Do not operate generator in the rain.
  • Do not handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.
  • Do not allow unqualified persons or children to operate or service generator.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator. Excessively low speeds impose a heavy load.

  • Do not tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.
  • Do not modify generator in any way.

CAUTION

Exceeding generators wattage/amperage cappacity can damage generator and/or electrical devices connected to it.

  • See “Don’t Overload Your Generator” on page 9.
  • Start generator and let engine stabilize before connecting electrical loads.
  • Connect electrical loads in OFF position, then turn ON for operation.
  • Turn electrical loads OFF and disconnect from generator before stopping generator.

CAUTION

DANGER Storage batteries give off explosive hydrogen gas during recharging. Hydrogen gas stays around battery for a long time after battery has been charged. Slightest spark will ignite hydrogen and cause explosion. You can be blinded or severely injured. Battery electrolyte fluid contains acid and is extremely caustic. Contact with battery fluid will cause severe chemical burns. • Do not allow any open flame, spark, heat, or lit cigarette during and for several minutes after charging a battery. • Wear protective goggles, rubber apron, and rubber gloves.

Improper treatment of generator can damage it and shorten its life.

  • Use generator only for intended uses.
  • If you have questions about intended use, ask dealer or contact Generac.
  • Operate generator only on level surfaces.
  • Do not expose generator to excessive moisture, dust, dirt, or corrosive vapors.
  • Do not insert any objects through cooling slots.
  • If connected devices overheat, turn them off and disconnect them from generator.
  • Shut off generator if: -electrical output is lost; -equipment sparks, smokes, or emits flames; -unit vibrates excessively.
Page 4 of the Generac 1654-0 user manual — REMOVE GENERATOR
Page 4 · click to enlarge
Page 4
Generac 1654-0 — REMOVE GENERATOR diagram (page 4)
Fig. 4
Generac 1654-0 — REMOVE GENERATOR diagram (page 4)
Fig. 5

Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel.

  • CARTON CONTENTS Check all contents. If any parts are missing or damaged, call the generator helpline at 1-800-270-1408.
  • The generator
  • Generator and engine owner’s manuals
  • Locking 30 Amp plug
  • Engine oil
  • Wheel kit INSTALL WHEEL KIT The wheel kit is designed to greatly improve the portability of your generator. NOTE: Wheel kit is not intended for over-the-road use. You will need a socket wrench with 1/2" or 13mm sockets and a needle-nose pliers to install this kit.

If you have any problems with the assembly of your generator, please call the generator helpline at 1-800-270-1408.

REMOVE GENERATOR

FROM CARTON

  • Set the carton on a rigid flat surface with “This Side Up” arrows pointing upward.
  • Carefully open the top flaps of the shipping carton.

Refer to Figure 1 and install the wheel kit as follows: 1. Place the generator on a hard flat surface. 2. Stand at the engine end of the generator and gently tilt the generator forward, high enough to place wooden blocks beneath the cradle.This will allow you to add the wheels.

  • Cut down corners at one end of carton from top to bottom and lay that side of carton down flat.
  • Remove all packing material, carton fillers, etc.
  • Remove the generator from the shipping carton.
Generac 1654-0 — REMOVE GENERATOR diagram (page 4)
Fig. 6

Use existing hardware to attach left side of support leg to unit

Page 5 of the Generac 1654-0 user manual — To fill your engine with oil:
Page 5 · click to enlarge
Page 5
3. Slide the axle through the holes in the brackets provided on the generator cradle.

Add Gasoline

4. Slide a wheel and flat washer on one end of the axle. Make sure the air inflation valve is outward. Insert the retaining pin.
5. Slide the axle through until wheel is tight against bracket.
6. Slide the other wheel and flat washer on the other end of the axle. Make sure the air inflation valve is outward. Insert the retaining pin using the needle-nose plier. Remove the wooden blocks.
  • Use regular UNLEADED gasoline with the generator engine. Do Not use premium gasoline. Do Not mix oil with gasoline.
7. Attach the vibration mounts to the support leg with 30mm capscrews, washers and lock nuts.
  • Clean area around fuel fill cap, remove cap.
  • Slowly add unleaded regular gasoline to fuel tank. Be careful not to overfill.Allow about 1.5" of tank space for fuel expansion (Figure 2).
8. To aid support leg assembly, rest generator on cradle, engine end down. Remove the existing hardware from the left unit vibration mount with 13mm wrench. Use the same hardware to attach the support leg.

Figure 2 — Typical Fuel Expansion Space

9. Attach the other side of the support leg with a 20mm cap screw and lock nut. Rest generator on wheels and support leg.

1.5” Airspace

10. Center the handle bracket on generator frame at support leg end of cradle, as shown.
11. Attach handle bracket with two M8 x 45mm cap screws and two locking hex nuts.
12. Check each fastener to ensure it is secure and the tires are inflated between 15-40 PSI.
  • Install fuel cap and wipe up any spilled gasoline.

IMPORTANT: It is important to prevent gum deposits from forming in essential fuel system parts, such as the carburetor, fuel filter, fuel hose or tank during storage.Also, experience indicates that alcohol–blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic fuel can damage the fuel system of an engine while in storage.

BEFORE STARTING THE

ENGINE

Add Oil

To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. See “Storage” on page 11. Never use engine or carburetor cleaner products in the fuel tank or permanent damage may occur.

To fill your engine with oil:

  • Place generator on a level surface.
  • Follow the oil grade recommendations and oil fill instructions given in the engine owner’s manual.

Tank · Fuel

Page 6 of the Generac 1654-0 user manual — KNOW YOUR GENERATOR
Page 6 · click to enlarge
Page 6
Generac 1654-0 — KNOW YOUR GENERATOR diagram (page 6)
Fig. 7
Generac 1654-0 — KNOW YOUR GENERATOR diagram (page 6)
Fig. 8

KNOW YOUR GENERATOR

Read this owner’s manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.

Generac 1654-0 — KNOW YOUR GENERATOR diagram (page 6)
Fig. 9

120 Volt AC, 20 Amp Duplex Receptacles

120 Volt AC, 20 Amp, Duplex Receptacles — May be used to supply electrical power for the operation of 120 Volt AC, 20 Amp, single phase, 60 Hz electrical, lighting, appliance, tool and motor loads. 120/240 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz electrical, lighting, appliance, tool and motor loads. Air Cleaner — Uses a dry type filter element to limit the amount of dirt and dust sucked into the engine. Choke Lever — Used when starting a cold engine.

Circuit Breakers (AC) — Push to reset circuit breakers are provided to protect the generator against electrical overload. Fuel Tank — Capacity of seven (7) U.S. gallons. Grounding Wing Nut — Used for proper grounding of unit (see page 7). Oil Fill — Add engine oil here. Recoil starter — Used to start the engine. Rocker Switch — Set this switch to "On" before using recoil starter. Set switch to "Off" to switch off engine. Spark Arrester Muffler — Exhaust muffler lowers engine noise and is equipped with a spark arrester screen.

Choke Lever

Page 7 of the Generac 1654-0 user manual — Starting the Engine
Page 7 · click to enlarge
Page 7
Generac 1654-0 — OPERATING THE diagram (page 7)
Fig. 10
Generac 1654-0 — OPERATING THE diagram (page 7)
Fig. 11
Generac 1654-0 — OPERATING THE diagram (page 7)
Fig. 12
1. Turn the fuel valve to the “ On ” position (Figure 4).

The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of the unit. For that purpose, a GROUNDING WING NUT is provided on the generator end (Figure 3).

2. Place the choke lever in the “ Choke ” position (Figure 5).

Generally, connecting a No. 12 AWG (American Wire Gauge) stranded copper wire to the grounding wing nut and to an earth–driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. Be careful to keep the grounding wire attached after connecting the stranded copper wire. However, local codes may vary widely. Consult with a local electrician for grounding requirements in your area.

3. Set the rocker switch to “ On ” position (Figure 6).
Generac 1654-0 — OPERATING THE diagram (page 7)
Fig. 13

Properly grounding the generator helps prevent electrical shock if a ground fault condition exists in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices.

4. Grasp the recoil handle and pull slowly until slight resistance is felt.Then pull rapidly to start engine.
5. Move choke lever to “ Run ” position a short distance at a time over several seconds in warm weather or minutes in cold weather. Let engine run smoothly before each change. Operate with choke in “ Run ” position.

OPERATING THE

GENERATOR

Refer to the engine owner’s manual for more detailed starting instructions.

Starting the Engine

Disconnect all electrical loads from the generator. Use the following start instruction steps by numerical order:

Page 8 of the Generac 1654-0 user manual — 120/240 Volt AC, 30 Amp, Locking Receptacle
Page 8 · click to enlarge
Page 8
  • Connecting Electrical Loads
  • Let engine stabilize and warm up for a few minutes after starting.
  • Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hz electrical loads.
  • Do Not connect 240 Volt loads to the 120 Volt duplex receptacles.
  • Do Not connect 3–phase loads to the generator.
  • Do Not connect 50 Hz loads to the generator.
  • DO NOT OVERLOAD THE GENERATOR. See “Don’t Overload the Generator” on page 9.

Figure 7 — 120/240 Volt AC, 30 Amp Receptacle

120V 120V W (Neutral)

  • Stopping the Engine
  • Unplug all electrical loads from generator panel receptacles. Never start or stop engine with electrical devices plugged in and turned ON .
  • Let engine run at no-load for several minutes to stabilize the internal temperatures of engine and generator.
  • Move rocker switch to “ Off ” position.
  • Move the fuel valve to the “ Off ” position. RECEPTACLES

X (Hot) Y (Hot)

NEMA L14-30 Ground (Green)

120 Volt AC, 20 Amp, Duplex Receptacles

Each duplex receptacle (Figure 8) is protected against overload by a push–to–reset circuit breaker.

Figure 8 — 120 Volt, 20 Amp Duplex Receptacle

120/240 Volt AC, 30 Amp, Locking Receptacle

Use a NEMA L14–30 plug with this receptacle. Connect a 4–wire cord set rated for 250 Volt AC loads at 30 Amps (or greater) (Figure 7).You can use the same 4–wire cord if you plan to run a 120 Volt load.

This receptacle powers 120/240 Volt AC, 60 Hz, single phase loads requiring up to 5,500 watts of power (5.5 kW) at 30 Amps for 120 Volts or 240 Volts.The outlet is protected by a push–to–reset circuit breaker.

Use each receptacle to operate 120 Volt AC, single–phase, 60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at 20 Amps of current. Use cord sets that are rated for 125 Volt AC loads at 20 Amps (or greater).

4-Wire Cord Set

Page 9 of the Generac 1654-0 user manual — Example:
Page 9 · click to enlarge
Page 9
Generac 1654-0 — DON'T OVERLOAD YOUR diagram (page 9)
Fig. 14

DON'T OVERLOAD YOUR

4. Plug in and turn on the next load. 5. Again, permit the generator to stabilize. 6. Repeat steps 4 and 5 for each additional load. Never add more loads than the generator capacity.Take special care to consider surge loads in generator capacity, as described above.

GENERATOR

Capacity You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: 1. Select the items you will power at the same time. 2. Total the rated (running) watts of these items.This is the amount of power your generator must produce to keep your items running. See Figure 9. 3. Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.

Figure 9 - Wattage Reference Chart Tool or ApplianceRated* (Running) WattsAdditional Surge (Starting) Watts Essentials Light Bulb - 75 watt75- Deep Freezer500500 Sump Pump8001200 Refrigerator/Freezer - 18 Cu. Ft.8001600 Water Well Pump - 1/3 HP10002000 Heating/Cooling Window AC - 10,000 BTU12001800 Window Fan300600 Furnace Fan Blower - 1/2 HP8001300 Kitchen Microwave Oven - 1000 Watt1000- Coffee Maker1500- Electric Stove - Single Element1500- Hot Plate2500- Family Room DVD/CD Player100- VCR100- Stereo Receiver450- Color Television - 27”500- Personal Computer w/17” monitor800- Other Security System180- AM/FM Clock Radio300- Garage Door Opener - 1/2 HP480520 Electric Water Heater - 40 Gallon4000- DIY/Job Site Quartz Halogen Work Light1000- Airless Sprayer - 1/3 HP6001200 Reciprocating Saw960960 Electric Drill - 1/2 HP10001000 Circular Saw - 7 1/4”15001500 Miter Saw - 10”18001800 Table Planer - 6”18001800 Table Saw/Radial Arm Saw - 10”20002000 Air Compressor - 1-1/2 HP25002500

Example:

Tool or ApplianceRated (Running) WattsAdditional Surge (Starting) Watts Window Air Conditioner12001800 Refrigerator8001600 Deep Freezer500500 Television500- Light (75 Watts)75- 3075 Total Running Watts1800 Highest Surge Watts

Total Rated (Running) Watts = 3075 Highest Additional Surge Watts = 1800 Total Generator Output Required = 4875

Power Management To prolong the life of your generator and attached devices, it is important to take care when adding electrical loads to your generator.There should be nothing connected to the generator outlets before starting it's engine.The correct and safe way to manage generator power is to sequentially add loads as follows: 1. With nothing connected to the generator, start the engine as described in this manual. 2. Plug in and turn on the first load, preferably the largest load you have. 3. Permit the generator output to stabilize (engine runs smoothly and attached device operates properly.

*Wattages listed are approximate only. Check tool or appliance for actual wattage.

Page 10 of the Generac 1654-0 user manual — Engine Maintenance
Page 10 · click to enlarge
Page 10
Generac 1654-0 — SPECIFICATIONS diagram (page 10)
Fig. 15
Generac 1654-0 — SPECIFICATIONS diagram (page 10)
Fig. 16

SPECIFICATIONS

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.

Maximum Surge Watts 8,500 watts Continuous Wattage Capacity 5,500 watts Power Factor 1.0 Rated Maximum Continuous AC Load Current:

At 120 Volts 45.8 Amps At 240 Volts 22.9 Amps Phase 1–phase Rated Frequency 60 Hertz Fuel Tank Capacity 7 U.S. gallons Shipping Weight 175 lbs. GENERAL MAINTENANCE

NOTE: Do Not use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation.Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

RECOMMENDATIONS

To Clean the Generator

The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. Never operate a damaged or defective generator.

  • Use a damp cloth to wipe exterior surfaces clean.
  • A soft bristle brush may be used to loosen caked on dirt or oil.
  • A vacuum cleaner may be used to pick up loose dirt and debris.
  • Low pressure air (not to exceed 25 psi) may be used to blow away dirt. Inspect cooling air slots and opening on generator.These openings must be kept clean and unobstructed.

Engine Maintenance

See engine owner’s manual for instructions.

If you need service for your engine, you need to determine the engine identification number.To do so, remove the rocker arm cover hood, item number 55 shown on page 16, by removing the four nuts and washers holding it in place.The engine model-type-trim number is stamped on the side of the inner cover attached to the engine. Have this number in hand when you call the engine service center for assistance.

Page 11 of the Generac 1654-0 user manual — Generator Storage
Page 11 · click to enlarge
Page 11

STORAGE

The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage.

Engine Storage

See engine owner’s manual for instructions.

Generator Storage

Other Storage Tips

  • Clean the generator as outlined in “To Clean the Generator.”
  • Do Not store gasoline from one season to another.
  • Replace fuel container if it starts to rust. Rust and/or dirt in fuel can cause problems if it's used with this unit.
  • Check that cooling air slots and openings on generator are open and unobstructed.
  • Store in clean and dry area.
Page 12 of the Generac 1654-0 user manual — TROUBLESHOOTING
Page 12 · click to enlarge
Page 12
Generac 1654-0 — TROUBLESHOOTING diagram (page 12)
Fig. 17
Generac 1654-0 — TROUBLESHOOTING diagram (page 12)
Fig. 18

TROUBLESHOOTING

ProblemCauseSolution Engine is running, but no AC output is available.1. Circuit breaker is open. 2. Poor connection or defective cord set. 3. Connected device is bad. 4. Fault in generator.1. Reset circuit breaker. 2. Check and repair. 3. Connect another device that is in good condition. 4. Contact Generac service facility. Engine runs good but bogs down when loads are connected.1. Short circuit in a connected load. 2. Generator is overloaded. 3. Engine speed is too slow. 4. Shorted generator circuit.1. Disconnect shorted electrical load. 2. See “Don’t Overload the Generator” on page 9. 3. Contact Briggs and Stratton service facility. 4. Contact Generac service facility. Engine will not start; or starts and runs rough.1. Rocker switch set to “Off”. 2. Fuel valve is in the “Closed” position. 3. Low oil level. 4. Dirty air cleaner. 5. Out of gasoline. 6. Stale gasoline. 7. Spark plug wire not connected to spark plug. 8. Bad spark plug. 9. Water in gasoline. 10. Overchoking. 11. Excessively rich fuel mixture. 12. Intake valve stuck open or closed. 13. Engine has lost compression.1. Set switch to “On”. 2. Turn fuel valve to the “Open” position. 3. Fill crankcase to proper level. 4. Clean or replace air cleaner. 5. Fill fuel tank. 6. Drain gas tank and fill with fresh fuel. 7. Connect wire to spark plug. 8. Replace spark plug. 9. Drain gas tank; fill with fresh fuel. 10. Set choke to “Off” position. 11. Contact Briggs service facility. 12. Contact Briggs service facility. 13. Contact Briggs service facility. Engine shuts down during operation.1. Out of gasoline. 2. Fault in engine.1. Fill fuel tank. 2. Contact Briggs service facility. Engine lacks power.1. Load is too high. 2. Dirty air filter.1. See “Don’t Overload the Generator” on page 9. 2. Replace air filter. Engine “hunts” or falters.1. Choke is opened too soon. 2. Carburetor is running too rich or too lean.1. Move choke to halfway position till engine runs smoothly. 2. Contact Briggs service facility.
Page 13 of the Generac 1654-0 user manual — NOTES
Page 13 · click to enlarge
Page 13
Generac 1654-0 — NOTES diagram (page 13)
Fig. 19

NOTES

Page 14 of the Generac 1654-0 user manual — SCHEMATIC
Page 14 · click to enlarge
Page 14
Generac 1654-0 — SCHEMATIC diagram (page 14)
Fig. 20

SCHEMATIC

Page 15 of the Generac 1654-0 user manual — SCHEMATIC
Page 15 · click to enlarge
Page 15
Generac 1654-0 — SCHEMATIC diagram (page 15)
Fig. 21
Generac 1654-0 — SCHEMATIC diagram (page 15)
Fig. 22
Page 16 of the Generac 1654-0 user manual — EXPLODED VIEW – MAIN UNIT
Page 16 · click to enlarge
Page 16
Generac 1654-0 — EXPLODED VIEW – MAIN UNIT diagram (page 16)
Fig. 23
Generac 1654-0 — EXPLODED VIEW – MAIN UNIT diagram (page 16)
Fig. 24

EXPLODED VIEW – MAIN UNIT

Generac 1654-0 — EXPLODED VIEW – MAIN UNIT diagram (page 16)
Fig. 25
Page 17 of the Generac 1654-0 user manual — PARTS LIST – MAIN UNIT
Page 17 · click to enlarge
Page 17

PARTS LIST – MAIN UNIT

Item Part # Qty Description 1 A189503GS 1 CRADLE 2 70642GS 2 MOUNT,Vibration, 45° 3 76222GS 4 PPHMS, M8 - 1.25 x 40 mm 4 66365GGS 1 HOUSING, Engine Adapter 5 187746GS 1 ASSEMBLY, Rotor (Inclds Item 7) 6 187745GS 1 ASSEMBLY, Stator 7 65791GS 1 BEARING 8 96796GS 1 WASHER, M8 Flat 9 189949GS 1 DECAL, Cover,Air Cleaner 10 86307GS 4 SCREW, SEMS 11 99383GS 1 SCREW 12 67022GS 1 GROMMET, Rubber 13 189127GS 1 GROMMET, Rubber 14 189009GS 1 BRACKET, Muffler 15 188551GS 1 GASKET, Exhaust 16 66476GS 2 SCREW, w/Lock Washer 17 189008GS 1 MUFFLER 18 60706GS 2 SCREW 19 83083GS 1 SCREEN, Spark Arrest 20 81917GS 1 PIN, 4mm x 10 Roll 21 67989GS 10 NUT, Flange Serrated 22 20566GS 1 DECAL, 1-800 # 23 86292GS 1 SCREW, Self Drilling 24 J190061GS 1 SHIELD, Heat 25 SRV66825DGS 1 CARRIER, Rear Bearing 26 74908GS 5 TAPTITE 27 86308AGS 4 BOLT, Stator 28 84409GS 1 SLEEVING, Flexo 29 22695GS 1 FASTEN, On Tab Housing 6P 30 84242GS 1 GROMMET, Plastic 31 77816GS 1 DECAL, Hot Muffler 32 91825GS 1 ASSEMBLY, Brush Holder 33 66849GS 2 TAPTITE 34 B4871GS 1 COVER, Bearing Carrier 35 23762GS 2 WASHER, Ext. Shakeproof 36 86494GS 1 SCREW,Wing

Item Part # Qty Description 37 B2153GS 2 SCREW, Self Drilling 38 56893GS 5 SCREW, Crimptite 39 189948GS 2 DECAL, Heat Shield 40 77395GS 4 NUT, M6 Flange Lock 41 80270GS 1 VALVE,Tank 42 78299GS 1 BUSHING, Plastic Tank 43 83465GS 4 GROMMET,Tank 44 78831BGS 4 HHCS, SEMS 45 B4363GS 1 CAP, Fuel Gauge 46 22097GS 4 WASHER, Lock 47 22127GS 4 NUT 48 14353621GS 1 WIRE, Ground 49 26850GS 2 WASHER, M6 Shakeproof 50 B4986GS 1 DECAL, Ground, Green 51 92982GS 1 DECAL, Danger 52 189235GS 1 DECAL, Start Instructions 53 85652GS 2 MOUNT,Vibration 54 92665GS 1 INSULATION 55 187330GS 1 HOOD, Rocker Arm Cover 56 85000GS 1 CLIP, Insulation 57 B1998GS 1 ASSY.,Tank, Fuel 7-Gallon (Includes Items 41 & 42) 58 189157GS 1 ASSEMBLY, Control Panel 59 189164GS 4 NUT, Palnut 60 J92039GS 1 SHIELD, Heat 61 189828GS 1 MANUAL, Owners 62 BB3061GS 1 BOTTLE, Oil, 28 oz 63 43438GS 1 PLUG, 250V, 30A 64 189521AGS 1 WIRE, Ground, Panel 65 188826GS 1 MANUAL, Engine 66 189949GS 1 DECAL, Panel, Control 67 73054GS 1 DECAL, Fuel Shut-off 68 L190018GS 1 PLATE, Stiffener 69 28739AGS 1 TIE WRAP 900 NSP 1 ENGINE

Page 18 of the Generac 1654-0 user manual — EXPLODED VIEW AND PARTS LIST – WHEEL KIT
Page 18 · click to enlarge
Page 18
Generac 1654-0 — EXPLODED VIEW AND PARTS LIST – WHEEL KIT diagram (page 18)
Fig. 26

EXPLODED VIEW AND PARTS LIST – WHEEL KIT

Generac 1654-0 — EXPLODED VIEW AND PARTS LIST – WHEEL KIT diagram (page 18)
Fig. 27

Item Part # Qty Description 1 189715GS 1 ASSEMBLY, Handle 2 B187101GS 1 LEG, Mounting 3 52858GS 5 NUT, Locking Hex 4 39287GS 2 HHCS, M8 - 1.25 x 45 5 93693GGS 1 AXLE 6 B4966GS 2 WHEEL 7 87005AGS 2 PIN, Retaining 8 22247GS 2 WASHER, Flat 9 39253GS 1 HHCS, M8 - 1.25 x 20 10 42909GS 2 HHCS, M8 - 1.25 x 30 11 22145GS 2 WASHER, Flat 12 27007GS 2 MOUNT,Vibration

Page 19 of the Generac 1654-0 user manual — EXPLODED VIEW AND PARTS LIST – CONTROL PANEL
Page 19 · click to enlarge
Page 19
Generac 1654-0 — EXPLODED VIEW AND PARTS LIST – CONTROL PANEL diagram (page 19)
Fig. 28

EXPLODED VIEW AND PARTS LIST – CONTROL PANEL

Generac 1654-0 — EXPLODED VIEW AND PARTS LIST – CONTROL PANEL diagram (page 19)
Fig. 29

Item Part # Qty Description 1 188914GS 1 COVER, Lid, Control Panel 2 188889GS 1 CONTROL PANEL, Compact 3 189167GS 2 CLIP, Hinge Pin Retainer 4 189182GS 2 SPRING, Hinge, Pin 5 189166GS 2 PIN, Hinge, Cover, Compact 6 68759GS 2 OUTLET, 120V, 20Amp, Duplex 7 189165GS 4 NUT, Palnut, Pushnut 8 84198GS 2 CAP, Circuit Breaker 9 75207GS 2 CIRCUIT BREAKER 10 43437GS 1 OUTLET, 120/240 Locking, 30A 11 189164GS 2 NUT, Palnut, Pushnut 12 84543CGS 2 SCREW, Phillips, Head 13 93857GS 1 BAR, Retaining 14 188890GS 1 COVER, Back, Control Panel 15 82308GS 6 SCREW, Self Tapping 16 22694GS 1 HOUSING, Receptacle

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Engine is running, but no AC output is available.1. Circuit breaker is open. 2. Poor connection or defective cord set. 3. Connected device is bad. 4. Fault in generator.1. Reset circuit breaker. 2. Check and repair. 3. Connect another device that is in good condition. 4. Contact Generac service facility. p.12
Engine runs good but bogs down when loads are connected.1. Short circuit in a connected load. 2. Generator is overloaded. 3. Engine speed is too slow. 4. Shorted generator circuit.1. Disconnect shorted electrical load. 2. See “Don’t Overload the Generator” on page 9. 3. Contact Briggs and Stratton service facility. 4. Contact Generac service facility. p.12
Engine will not start; or starts and runs rough.1. Rocker switch set to “Off”. 2. Fuel valve is in the “Closed” position. 3. Low oil level. 4. Dirty air cleaner. 5. Out of gasoline. 6. Stale gasoline. 7. Spark plug wire not connected to spark plug. 8. Bad spark plug. 9. Water in gasoline. 10. Overchoking. 11. Excessively rich fuel mixture. 12. Intake valve stuck open or closed. 13. Engine has lost compression.1. Set switch to “On”. 2. Turn fuel valve to the “Open” position. 3. Fill crankcase to proper level. 4. Clean or replace air cleaner. 5. Fill fuel tank. 6. Drain gas tank and fill with fresh fuel. 7. Connect wire to spark plug. 8. Replace spark plug. 9. Drain gas tank; fill with fresh fuel. 10. Set choke to “Off” position. 11. Contact Briggs service facility. 12. Contact Briggs service facility. 13. Contact Briggs service facility. p.12
Engine shuts down during operation.1. Out of gasoline. 2. Fault in engine.1. Fill fuel tank. 2. Contact Briggs service facility. p.12
Engine lacks power.1. Load is too high. 2. Dirty air filter.1. See “Don’t Overload the Generator” on page 9. 2. Replace air filter. p.12
Engine “hunts” or falters.1. Choke is opened too soon. 2. Carburetor is running too rich or too lean.1. Move choke to halfway position till engine runs smoothly. 2. Contact Briggs service facility. p.12

Ask about the Generac 1654-0

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Generac 1654-0

Be the first to ask — other owners or our team will answer.

Original document

Generac 1654-0 manual PDF

32 pages·2 MB·Portable Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…