Parts Included* / Piezas Incluidas* Table of Contents / Tabla de Contenidos
Safety Rules / Reglas De Seguridad 2-3 / 20-21 Assembly / Ensamblaje 4-5 / 22-23 Know Your Generator / Conozca Su Generador 6 / 24 Operation / Funcionamiento 7-9 / 25-27 Product Specifications / Especificaciones Del Producto 10 / 28 Maintenance / Mantenimiento 10 / 28 Storage / Almacenamiento 11 / 29 Troubleshooting / Diagnosticos De Averías 12 / 30 Schematic / Esquemático 14 Wiring Diagram / Digrama Eléctrico 15 Replacement Parts / Piezas De Recambio 16-19 Notes / Notas 13 Garantia 31 Warranty Last Page
Questions? Help is just a moment away! Preguntas? La ayuda es justa un momento lejos! Call: Generac Generator Helpline - 1-800-270-1408 M-F 8-5 CT Llamada: Generador Helpline De Generac - 1-800-270-1408 M-F 8-5 CT Web: www.generac-portables.com or www.briggsandstratton.com
Model No. 1654-0 (5,500 Watt AC Generator) Manual No. 189828GS Revision 1 (02/05/2002)


DANGER
DESCRIPTION Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved. This generator is an engine–driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliances, tools and motor loads.The generator’s revolving field is driven at about 3,600 rpm by a single-cylinder engine.
Running generator gives off carbon monoxide, an ordorless, colorless, poison gas. Breathing carbon monoxide will cause nausea, fainting or death.
Every effort has been made to ensure that information in this manual is accurate and current. However, Generac reserves the right to change, alter or otherwise improve the product and this document at any time without prior notice. The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency. For warranty information refer to the engine owner’s manual.
Gasoline and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
The safety alert symbol ( ) is used with a signal word (DANGER, CAUTION,WARNING), a pictorial and/or a safety message to alert you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury. WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. CAUTION, when used without the alert symbol, indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.
WHEN STORING GASOLINE OR EQUIPMENT WITH FUEL IN TANK


WARNING
Generator produces powerful voltage. Failure to properly ground generator can result in electrocution. Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.
Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C). Severe burns can occur on contact.
Excessively high operating speeds increase risk of injury and damage to generator. Excessively low speeds impose a heavy load.
Exceeding generators wattage/amperage cappacity can damage generator and/or electrical devices connected to it.
Improper treatment of generator can damage it and shorten its life.



Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel.
If you have any problems with the assembly of your generator, please call the generator helpline at 1-800-270-1408.
FROM CARTON
Refer to Figure 1 and install the wheel kit as follows: 1. Place the generator on a hard flat surface. 2. Stand at the engine end of the generator and gently tilt the generator forward, high enough to place wooden blocks beneath the cradle.This will allow you to add the wheels.

Use existing hardware to attach left side of support leg to unit

Figure 2 — Typical Fuel Expansion Space
1.5” Airspace
IMPORTANT: It is important to prevent gum deposits from forming in essential fuel system parts, such as the carburetor, fuel filter, fuel hose or tank during storage.Also, experience indicates that alcohol–blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic fuel can damage the fuel system of an engine while in storage.
ENGINE
Add Oil
To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. See “Storage” on page 11. Never use engine or carburetor cleaner products in the fuel tank or permanent damage may occur.
Tank · Fuel



Read this owner’s manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.

120 Volt AC, 20 Amp Duplex Receptacles
120 Volt AC, 20 Amp, Duplex Receptacles — May be used to supply electrical power for the operation of 120 Volt AC, 20 Amp, single phase, 60 Hz electrical, lighting, appliance, tool and motor loads. 120/240 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz electrical, lighting, appliance, tool and motor loads. Air Cleaner — Uses a dry type filter element to limit the amount of dirt and dust sucked into the engine. Choke Lever — Used when starting a cold engine.
Circuit Breakers (AC) — Push to reset circuit breakers are provided to protect the generator against electrical overload. Fuel Tank — Capacity of seven (7) U.S. gallons. Grounding Wing Nut — Used for proper grounding of unit (see page 7). Oil Fill — Add engine oil here. Recoil starter — Used to start the engine. Rocker Switch — Set this switch to "On" before using recoil starter. Set switch to "Off" to switch off engine. Spark Arrester Muffler — Exhaust muffler lowers engine noise and is equipped with a spark arrester screen.
Choke Lever




The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of the unit. For that purpose, a GROUNDING WING NUT is provided on the generator end (Figure 3).
Generally, connecting a No. 12 AWG (American Wire Gauge) stranded copper wire to the grounding wing nut and to an earth–driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. Be careful to keep the grounding wire attached after connecting the stranded copper wire. However, local codes may vary widely. Consult with a local electrician for grounding requirements in your area.

Properly grounding the generator helps prevent electrical shock if a ground fault condition exists in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices.
GENERATOR
Refer to the engine owner’s manual for more detailed starting instructions.
Disconnect all electrical loads from the generator. Use the following start instruction steps by numerical order:

Figure 7 — 120/240 Volt AC, 30 Amp Receptacle
120V 120V W (Neutral)
X (Hot) Y (Hot)
120 Volt AC, 20 Amp, Duplex Receptacles
Each duplex receptacle (Figure 8) is protected against overload by a push–to–reset circuit breaker.
Figure 8 — 120 Volt, 20 Amp Duplex Receptacle
Use a NEMA L14–30 plug with this receptacle. Connect a 4–wire cord set rated for 250 Volt AC loads at 30 Amps (or greater) (Figure 7).You can use the same 4–wire cord if you plan to run a 120 Volt load.
This receptacle powers 120/240 Volt AC, 60 Hz, single phase loads requiring up to 5,500 watts of power (5.5 kW) at 30 Amps for 120 Volts or 240 Volts.The outlet is protected by a push–to–reset circuit breaker.
Use each receptacle to operate 120 Volt AC, single–phase, 60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at 20 Amps of current. Use cord sets that are rated for 125 Volt AC loads at 20 Amps (or greater).
4-Wire Cord Set


Capacity You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: 1. Select the items you will power at the same time. 2. Total the rated (running) watts of these items.This is the amount of power your generator must produce to keep your items running. See Figure 9. 3. Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.
Total Rated (Running) Watts = 3075 Highest Additional Surge Watts = 1800 Total Generator Output Required = 4875
Power Management To prolong the life of your generator and attached devices, it is important to take care when adding electrical loads to your generator.There should be nothing connected to the generator outlets before starting it's engine.The correct and safe way to manage generator power is to sequentially add loads as follows: 1. With nothing connected to the generator, start the engine as described in this manual. 2. Plug in and turn on the first load, preferably the largest load you have. 3. Permit the generator output to stabilize (engine runs smoothly and attached device operates properly.
*Wattages listed are approximate only. Check tool or appliance for actual wattage.



Generator Maintenance
Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.
Maximum Surge Watts 8,500 watts Continuous Wattage Capacity 5,500 watts Power Factor 1.0 Rated Maximum Continuous AC Load Current:
At 120 Volts 45.8 Amps At 240 Volts 22.9 Amps Phase 1–phase Rated Frequency 60 Hertz Fuel Tank Capacity 7 U.S. gallons Shipping Weight 175 lbs. GENERAL MAINTENANCE
NOTE: Do Not use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation.Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.
To Clean the Generator
The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. Never operate a damaged or defective generator.
See engine owner’s manual for instructions.
If you need service for your engine, you need to determine the engine identification number.To do so, remove the rocker arm cover hood, item number 55 shown on page 16, by removing the four nuts and washers holding it in place.The engine model-type-trim number is stamped on the side of the inner cover attached to the engine. Have this number in hand when you call the engine service center for assistance.

The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage.
See engine owner’s manual for instructions.
Other Storage Tips















Item Part # Qty Description 1 A189503GS 1 CRADLE 2 70642GS 2 MOUNT,Vibration, 45° 3 76222GS 4 PPHMS, M8 - 1.25 x 40 mm 4 66365GGS 1 HOUSING, Engine Adapter 5 187746GS 1 ASSEMBLY, Rotor (Inclds Item 7) 6 187745GS 1 ASSEMBLY, Stator 7 65791GS 1 BEARING 8 96796GS 1 WASHER, M8 Flat 9 189949GS 1 DECAL, Cover,Air Cleaner 10 86307GS 4 SCREW, SEMS 11 99383GS 1 SCREW 12 67022GS 1 GROMMET, Rubber 13 189127GS 1 GROMMET, Rubber 14 189009GS 1 BRACKET, Muffler 15 188551GS 1 GASKET, Exhaust 16 66476GS 2 SCREW, w/Lock Washer 17 189008GS 1 MUFFLER 18 60706GS 2 SCREW 19 83083GS 1 SCREEN, Spark Arrest 20 81917GS 1 PIN, 4mm x 10 Roll 21 67989GS 10 NUT, Flange Serrated 22 20566GS 1 DECAL, 1-800 # 23 86292GS 1 SCREW, Self Drilling 24 J190061GS 1 SHIELD, Heat 25 SRV66825DGS 1 CARRIER, Rear Bearing 26 74908GS 5 TAPTITE 27 86308AGS 4 BOLT, Stator 28 84409GS 1 SLEEVING, Flexo 29 22695GS 1 FASTEN, On Tab Housing 6P 30 84242GS 1 GROMMET, Plastic 31 77816GS 1 DECAL, Hot Muffler 32 91825GS 1 ASSEMBLY, Brush Holder 33 66849GS 2 TAPTITE 34 B4871GS 1 COVER, Bearing Carrier 35 23762GS 2 WASHER, Ext. Shakeproof 36 86494GS 1 SCREW,Wing
Item Part # Qty Description 37 B2153GS 2 SCREW, Self Drilling 38 56893GS 5 SCREW, Crimptite 39 189948GS 2 DECAL, Heat Shield 40 77395GS 4 NUT, M6 Flange Lock 41 80270GS 1 VALVE,Tank 42 78299GS 1 BUSHING, Plastic Tank 43 83465GS 4 GROMMET,Tank 44 78831BGS 4 HHCS, SEMS 45 B4363GS 1 CAP, Fuel Gauge 46 22097GS 4 WASHER, Lock 47 22127GS 4 NUT 48 14353621GS 1 WIRE, Ground 49 26850GS 2 WASHER, M6 Shakeproof 50 B4986GS 1 DECAL, Ground, Green 51 92982GS 1 DECAL, Danger 52 189235GS 1 DECAL, Start Instructions 53 85652GS 2 MOUNT,Vibration 54 92665GS 1 INSULATION 55 187330GS 1 HOOD, Rocker Arm Cover 56 85000GS 1 CLIP, Insulation 57 B1998GS 1 ASSY.,Tank, Fuel 7-Gallon (Includes Items 41 & 42) 58 189157GS 1 ASSEMBLY, Control Panel 59 189164GS 4 NUT, Palnut 60 J92039GS 1 SHIELD, Heat 61 189828GS 1 MANUAL, Owners 62 BB3061GS 1 BOTTLE, Oil, 28 oz 63 43438GS 1 PLUG, 250V, 30A 64 189521AGS 1 WIRE, Ground, Panel 65 188826GS 1 MANUAL, Engine 66 189949GS 1 DECAL, Panel, Control 67 73054GS 1 DECAL, Fuel Shut-off 68 L190018GS 1 PLATE, Stiffener 69 28739AGS 1 TIE WRAP 900 NSP 1 ENGINE



Item Part # Qty Description 1 189715GS 1 ASSEMBLY, Handle 2 B187101GS 1 LEG, Mounting 3 52858GS 5 NUT, Locking Hex 4 39287GS 2 HHCS, M8 - 1.25 x 45 5 93693GGS 1 AXLE 6 B4966GS 2 WHEEL 7 87005AGS 2 PIN, Retaining 8 22247GS 2 WASHER, Flat 9 39253GS 1 HHCS, M8 - 1.25 x 20 10 42909GS 2 HHCS, M8 - 1.25 x 30 11 22145GS 2 WASHER, Flat 12 27007GS 2 MOUNT,Vibration



Item Part # Qty Description 1 188914GS 1 COVER, Lid, Control Panel 2 188889GS 1 CONTROL PANEL, Compact 3 189167GS 2 CLIP, Hinge Pin Retainer 4 189182GS 2 SPRING, Hinge, Pin 5 189166GS 2 PIN, Hinge, Cover, Compact 6 68759GS 2 OUTLET, 120V, 20Amp, Duplex 7 189165GS 4 NUT, Palnut, Pushnut 8 84198GS 2 CAP, Circuit Breaker 9 75207GS 2 CIRCUIT BREAKER 10 43437GS 1 OUTLET, 120/240 Locking, 30A 11 189164GS 2 NUT, Palnut, Pushnut 12 84543CGS 2 SCREW, Phillips, Head 13 93857GS 1 BAR, Retaining 14 188890GS 1 COVER, Back, Control Panel 15 82308GS 6 SCREW, Self Tapping 16 22694GS 1 HOUSING, Receptacle
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Engine is running, but no AC output is available. | 1. Circuit breaker is open. 2. Poor connection or defective cord set. 3. Connected device is bad. 4. Fault in generator. | 1. Reset circuit breaker. 2. Check and repair. 3. Connect another device that is in good condition. 4. Contact Generac service facility. | p.12 |
| Engine runs good but bogs down when loads are connected. | 1. Short circuit in a connected load. 2. Generator is overloaded. 3. Engine speed is too slow. 4. Shorted generator circuit. | 1. Disconnect shorted electrical load. 2. See “Don’t Overload the Generator” on page 9. 3. Contact Briggs and Stratton service facility. 4. Contact Generac service facility. | p.12 |
| Engine will not start; or starts and runs rough. | 1. Rocker switch set to “Off”. 2. Fuel valve is in the “Closed” position. 3. Low oil level. 4. Dirty air cleaner. 5. Out of gasoline. 6. Stale gasoline. 7. Spark plug wire not connected to spark plug. 8. Bad spark plug. 9. Water in gasoline. 10. Overchoking. 11. Excessively rich fuel mixture. 12. Intake valve stuck open or closed. 13. Engine has lost compression. | 1. Set switch to “On”. 2. Turn fuel valve to the “Open” position. 3. Fill crankcase to proper level. 4. Clean or replace air cleaner. 5. Fill fuel tank. 6. Drain gas tank and fill with fresh fuel. 7. Connect wire to spark plug. 8. Replace spark plug. 9. Drain gas tank; fill with fresh fuel. 10. Set choke to “Off” position. 11. Contact Briggs service facility. 12. Contact Briggs service facility. 13. Contact Briggs service facility. | p.12 |
| Engine shuts down during operation. | 1. Out of gasoline. 2. Fault in engine. | 1. Fill fuel tank. 2. Contact Briggs service facility. | p.12 |
| Engine lacks power. | 1. Load is too high. 2. Dirty air filter. | 1. See “Don’t Overload the Generator” on page 9. 2. Replace air filter. | p.12 |
| Engine “hunts” or falters. | 1. Choke is opened too soon. 2. Carburetor is running too rich or too lean. | 1. Move choke to halfway position till engine runs smoothly. 2. Contact Briggs service facility. | p.12 |