MODEL: 005789-0
Owner’s Manual


www.generac.com
or 1-888-GENERAC


INTRODUCTION Thank you for purchasing this model by Generac Power Systems, Inc. This model is a compact, high performance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads on job sites, or remote locations where no utility power is available or in place of utility due to a power outage.
The operator is responsible for proper and safe use of the equipment. We strongly recommend that the operator read this manual and thoroughly understand all instructions before using the equipment.
We also strongly recommend instructing other users to properly start and operate the unit. This prepares them if they need to operate the equipment in an emergency.
READ THIS MANUAL THOROUGHLY If any portion of this manual is not understood, contact the nearest Authorized Dealer for starting, operating and servicing procedures.
MINUTES. Exhaust contains carbon monoxide, a poison gas you cannot see or smell. NEVER use in the home, or in partly enclosed
Throughout this publication, and on tags and decals affixed to the generator, DANGER, WARNING, CAUTION and NOTICE blocks are used to alert personnel to special instructions about a particular operation that may be hazardous if performed incorrectly or carelessly. Observe them carefully. Their definitions are as follows:
areas such as garages. ONLY use outdoors and far from open windows, doors, vents, and in an area that will not accumulate deadly exhaust gas.

Using a generator indoors WILL KILL YOU IN MINUTES. Exhaust contains carbon monoxide, a poison gas you cannot see or smell.
not strictly complied with, will result in serious personal injury, including death and/or property damage.
NEVER use in the home or in partly enclosed areas such as garages. ONLY use outdoors and far from open windows, doors and vents.
strictly complied with, may result in serious personal injury and/or property damage.
strictly complied with, could result in damage to equipment and/or property, and minor injury.
After this heading, read explanatory statements that require
special emphasis and relate to property damage.
These safety warnings cannot eliminate the hazards that they indicate. Common sense and strict compliance with the special instructions while performing the service are essential to preventing accidents.
Four commonly used safety symbols accompany the DANGER, WARNING and CAUTION blocks. The type of information each indicates is as follows: This symbol points out important safety
information that, if not followed, could endanger personal safety and/or property of others. This symbol points out potential explosion
hazard. This symbol points out potential fire hazard.
hazard.
generator and engine to cool entirely before adding fuel.

SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted near the unit's
installation site. Safety should be stressed to all operators and potential operators of this equipment.
Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this manual and with the unit. The generator can operate safely, efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental rules or precautions.
The manufacturer cannot anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and on tags and decals affixed to the unit are, therefore, not all inclusive. If using a procedure, work method or operating technique that the manufacturer does not specifically recommend, ensure that it is safe for others. Also make sure the procedure, work method or operating technique utilized does not render the generator unsafe.
operating this equipment imprudently, neglecting its maintenance or being careless can cause possible injury or death. Permit only responsible and capable persons to operate or maintain this equipment. Potentially lethal voltages are generated by
garage, near an open window, door, ventilated intake, crawl space, other opening, or in an area that could accumulate exhaust gas.
these machines. Ensure all steps are taken to render the machine safe before attempting to work on the generator. Parts of the generator are rotating and/or hot
during operation. Exercise care near running generators. Do not touch hot surfaces such as the muffler. Severe burns can occur on contact. Allow generator to cool before touching.
Th e engine exhaust from this product contains chemicals known to the state of California to cause cancer, birth de-
fects or other reproductive harm.
known to the state of California to cause cancer, birth defects or other reproductive harm.

In the absence of pertinent standards, codes, regulations and laws, the published information listed below may be used as a guideline for operation of this equipment. Always reference the latest revision available for the standards listed.
1. NFPA No. 70, NFPA HANDBOOK OF NATIONAL ELECTRIC CODE. 2. Article X, NATIONAL BUILDING CODE, available from the American Insurance Association, 85 John Street, New York, N.Y. 10038. 3. AGRICULTURAL WIRING HANDBOOK, available from the Food and Energy Council, 909 University Avenue, Columbia, MO 65201. 4. ASAE EP-3634, INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS, available from the American Society of Agricultural Engineers, 2950 Niles Road, St. Joseph, MI 49085. 5. NFPA No. 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE.

1.1 UNPACKING
Figure 1 – Wheel Assembly

Check all contents. If any parts are missing or damaged, locate an authorized dealer at 1-888-436-3722.
1.2 ASSEMBLY The generator requires some assembly prior to using it. If problems arise when assembling the generator, please call the Generator Helpline at 1-888-436-3722.

The wheels are designed to the unit to greatly improve the portability of the generator.
The wheels are not intended for over-the-road-use.
2.1 KNOW THE GENERATOR Read the Owner’s Manual and Safety Rules before operating this generator.
Compare the generator to Figures 3 through 6 to become familiarized with the locations of various controls and adjustments. Save this manual for future reference.

4. Choke Knob – Used when starting a cold engine. 5. Fuel Tank – Tank holds 4 U.S. gallons of fuel. 6. Grounding Lug – Ground the generator to an approved earth ground here. See "Grounding the Generator" for details. 7. On/OFF Switch – Controls the operation of the generator. 8. Muffler – Quiets the engine. 9. Handle – Pivot and retract for storage. 10. Gas Cap – Fuel fill location. 11. Fuel Gauge – Shows fuel level in tank. 12. Oil Check/Fill – Check and fill oil here. 13. Recoil Starter – Use to start engine manually. 14. Fuel Shut Off – Valve between fuel tank and carburetor. 15. Oil Drain Plug – Used to drain engine oil. 16. Spark Arrestor – Reduces fire hazard by containing sparks. 17. Roll Over Valve – Passes fuel vapors to the carbon canister. 18. Carbon Canister – Absorbs fuel tank vapors. 19. Recovery Hose – Installed between items 17 & 18.

Figure 6 - Generator Controls




2.2 CORD SETS AND CONNECTION PLUGS
Figure 7 - Grounding the Generator

This is a 120 Volt outlet protected against overload by a 13.5 Amp push-to-reset circuit breaker (Figure 6). 13.5 Amps of current may be drawn from each socket, however, total power drawn must be kept within data plate ratings. Use only high quality, well insulated, 3-wire grounded cord sets rated for 125 Volts at 20 Amps (or greater).
2.3 HOW TO USE THE GENERATOR If there are any problems operating the generator, please call the generator helpline at 1-888-436-3722.
MINUTES. Exhaust contains carbon monoxide, a poison gas you cannot see or smell. NEVER use in the home, or in partly enclosed
DO NOT connect 240 Volt loads to 120 Volt receptacles. DO NOT connect 3-phase loads to the generator. DO NOT connect 50 Hz loads to the generator.
areas such as garages. ONLY use outdoors and far from open windows, doors, vents, and in an area that will not accumulate deadly exhaust gas.

Using a generator indoors WILL KILL YOU IN MINUTES. Exhaust contains carbon monoxide, a poison gas you cannot see or smell.
2.4 DON’T OVERLOAD THE GENERATOR Overloading a generator in excess of its rated wattage capacity can result in damage to the generator and to connected electrical devices. Observe the following to prevent overloading the unit:
NEVER use in the home or in partly enclosed areas such as garages. ONLY use outdoors and far from open windows, doors and vents.
The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground (Figure 7). Local electrical codes may also require proper grounding of the unit. For that purpose, connecting a No. 10 AWG (American Wire Gauge) stranded copper wire to the grounding lug and to an earth-driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. However, local codes may vary widely. Consult with a local electrician for grounding requirements in the area.
Proper grounding of the generator will help prevent electrical shock in the event of a ground fault condition in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices.

2.6 BEFORE STARTING THE GENERATOR Prior to operating the generator, engine oil and gasoline will need to be added, as follows:
2.5 WATTAGE REFERENCE GUIDE Device Running Watts *Air Conditioner (12,000 Btu) 1700 *Air Conditioner (24,000 Btu) 3800 *Air Conditioner (40,000 Btu) 6000 Battery Charger (20 Amp) 500 Belt Sander (3") 1000 Chain Saw 1200 Circular Saw (6-1/2") 800 to 1000 *Clothes Dryer (Electric) 5750 *Clothes Dryer (Gas) 700 *Clothes Washer 1150 Coffee Maker 1750 *Compressor (1 HP) 2000 *Compressor (3/4 HP) 1800 *Compressor (1/2 HP) 1400 Curling Iron 700 *Dehumidifier 650 Disc Sander (9") 1200 Edge Trimmer 500 Electric Blanket 400 Electric Nail Gun 1200 Electric Range (per element) 1500 Electric Skillet 1250 *Freezer 700 *Furnace Fan (3/5 HP) 875 *Garage Door Opener 500 to 750 Hair Dryer 1200 Hand Drill 250 to 1100 Hedge Trimmer 450 Impact Wrench 500 Iron 1200 *Jet Pump 800 Lawn Mower 1200 Light Bulb 100 Microwave Oven 700 to 1000 *Milk Cooler 1100 Oil Burner on Furnace 300 Oil Fired Space Heater (140,000 Btu) 400 Oil Fired Space Heater (85,000 Btu) 225 Oil Fired Space Heater (30,000 Btu) 150 *Paint Sprayer, Airless (1/3 HP) 600 Paint Sprayer, Airless (handheld) 150 Radio 50 to 200 *Refrigerator 700 Slow Cooker 200 *Submersible Pump (1-1/2 HP) 2800 *Submersible Pump (1 HP) 2000 *Submersible Pump (1/2 HP) 1500 *Sump Pump 800 to 1050 *Table Saw (10") 1750 to 2000 Television 200 to 500 Toaster 1000 to 1650 Weed Trimmer 500 * Allow 3 times the listed watts for starting these devices.
All oil should meet minimum American Petroleum Institute (API) Service Class SJ, SL or better. Use no special additives. Select the oil's viscosity grade according to the expected operating temperature (also see chart).

Never fill fuel tank indoors. Never fill fuel tank
when engine is running or hot. Allow engine to cool entirely before filling fuel tank. Avoid spilling gasoline on HOT engine. DO NOT light a cigarette or smoke when filling the fuel tank. Gasoline is highly FLAMMABLE and its vapors are EXPLOSIVE.

If engine fires, but does not continue to run, move choke lever to the START position and repeat starting instructions.
CHOKE
Figure 8 - Fuel Tank

ON/OFF SWITCH
RECOIL HANDLE
IMPORTANT: It is important to prevent gum deposits from forming in fuel system parts such as the carburetor, fuel hose or tank during storage. Alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage. To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. See the "Storage" section. Never use engine or carburetor cleaner products in the fuel tank as permanent damage may occur.

2.7 TO START THE ENGINE

2.8 STOPPING THE ENGINE
3.2.2 ENGINE SPECIFICATIONS
Displacement 208 cc Spark Plug Type F6TC, NGK BPR4ES or Champion RN14YC Spark Plug Gap 0.028-0.031 inch or (0.70-0.80 mm) Gasoline Capacity 15.14 L (4 U.S. gallons) Oil Type See Chart in "Before Starting the Generator" Section Oil Capacity 0.6 L (0.634 Qts.) Run Time 12.5 Hours at 1/2 Load Class II Emission Certified* * The engine manufacturer must warrant the emission control system for a period of two years. This warranty coverage is in addition to the warranty provided by Generac, and may cover the engine even if Generac’s warranty does not.
2.9 LOW OIL LEVEL SHUTDOWN SYSTEM The engine is equipped with a low oil level sensor that shuts down the engine automatically when the oil level drops below a specified level. If the engine shuts down by itself and the fuel tank has enough gasoline, check engine oil level.
3.3 GENERAL RECOMMENDATIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.
If the system senses a low oil level during operation, the engine shuts down. The engine will not run until the oil has been refilled to the proper level.
Some adjustments will need to be made periodically to properly maintain the generator.
3.1 MAINTENANCE SCHEDULE Follow the calendar intervals. More frequent service is required when operating in adverse conditions noted below.
All adjustments in the Maintenance section of this manual should be made at least once each season. Follow the requirements in the "Maintenance Schedule".
Check Oil Level At Each Use Change Oil + *Every Season Check Valve Clearance ***Every Season Service Air Filter **Every Season Replace Spark Plug Every Season
Once a year replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help the engine run better and last longer.
+ Change oil after first 20 hours of operation, then every season. * Change oil every month when operating under heavy load or in high temperatures. ** Clean more often under dirty or dusty operating conditions. Replace air filter parts if they cannot be adequately cleaned. *** Check valve clearance and adjust if necessary after first 50 hours of operation and every 100 hours thereafter.
Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material.
Check the cleanliness of the generator frequently and clean when dust, dirt, oil, moisture or other foreign substances are visible on its exterior surface.
Rated. Power 3.25 kW** Surge Power 3.75 kW Rated AC Voltage 120 Rated Current 27 Amps** Rated Frequency 60 Hz @ 3600 RPM Phase Single Phase
cooling slots, even if the engine is not running.
DO NOT use a garden hose to clean generator. Water can enter the engine fuel system and cause problems. In addition, if water enters the generator through cooling air slots, some water will be retained in voids and crevices of the rotor and stator winding insulation. Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.
** Maximum wattage is subject to, and limited by, such factors as fuel Btu content, ambient temperature, altitude, engine condition, etc.. Maximum power decreases about 3.5% for each 1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F) ambient temperature.

3.3.2 TO CLEAN THE GENERATOR
Use the following instructions to change the oil while the engine is still warm:
3.3.6 REPLACING THE SPARK PLUG
Use spark plug F6TC, NGK BPR4ES or Champioin RN14YC. Replace the plug once each year. This will help the engine start easier and run better.
disconnect spark plug wire from spark plug and keep wire away from spark plug.
See the “Before Starting the Generator” section for information on checking the oil level. The oil level should be checked before each use, or at least every eight hours of operation. Keep the oil level maintained (Figure 11).
Figure 12 - Spark Plug Gap


Oil Check & Fill
Change the oil after the first eight hours of operation, then every 20 hours thereafter. If running this unit under dirty or dusty conditions, or in extremely hot weather, change the oil more often.
3.4 SERVICE AIR FILTER The engine will not run properly and may be damaged if using a dirty air filter. Clean the air filter once a year (Figure 13). Clean or replace more often if operating under dusty conditions.
before draining oil. Avoid prolonged or repeated skin exposure with used oil. Thoroughly wash exposed areas with soap.

NOTE:
3.7 LONG TERM STORAGE It is important to prevent gum deposits from forming in essential fuel system parts such as the carburetor, fuel hose or tank during storage. Also, experience indicates that alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage.
To order a new air filter, please contact the nearest authorized service center at 1-888-436-3722.

To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer, as follows:
Remove all gasoline from the fuel tank. •
3.6 GENERAL The generator should be started at least once every seven days and be allowed to run at least 30 minutes. If this cannot be done and the unit must be stored for more than 30 days, use the following information as a guide to prepare it for storage.
or in enclosed, poorly ventilated areas where fumes may reach an open flame, spark or pilot light as on a furnace, water heater, clothes dryer or other gas appliance.
exhaust areas are warm.
Air Cleaner Cover · Air Filter

4.1 TROUBLESHOOTING GUIDE
PROBLEM CAUSE CORRECTION
Engine is running, but no AC output is available.
Engine runs good but bogs down when loads are connected.
Engine will not start; or starts and runs rough.
Engine shuts down during operation.
Engine lacks power. 1. Load is too high. 2. Dirty air filter. 3. Engine needs to be serviced.
Engine “hunts” or falters. 1. Choke is opened too soon.


FEDERAL EMISSION CONTROL WARRANTY STATEMENT
YOUR WARRANTY RIGHTS AND OBLIGATIONS
The United States Environmental Protection Agency (EPA) and Generac Power Systems, Inc. (Generac) are pleased to explain the Emission Control System warranty on your new 2008 and later equipment. New equipment that use small spark-ignited engines must be designed, built, and equipped to meet stringent anti-smog standards for the federal government. Generac will warrant the emission control system on your generator for the period of time listed below provided there has been no abuse, neglect, unapproved modification or improper maintenance of your equipment. Your emission control system may include parts such as the: carburetor, ignition system, fuel system, catalytic converter, and other associated emission-related components (if equipped).
MANUFACTURER’S WARRANTY COVERAGE: This emission control system is warranted for two years. If, during such warranty period, any emission-related part on your equipment is found to be defective in materials or workmanship, repairs or replacement will be performed by a Generac Authorized Warranty Service Dealer.
OWNER'S WARRANTY RESPONSIBILITIES: As the generator owner, you are responsible for the completion of all required maintenance as listed in your factory supplied Owner's Manual. For warranty purposes, Generac recommends that you retain all receipts covering maintenance on your generator, but Generac cannot deny warranty solely due to the lack of receipts.
As the generator owner, you should be aware that Generac may deny any and/or all warranty coverage or responsibility if your generator, or a part/component thereof, has failed due to abuse, neglect, improper maintenance or unapproved modifications, or the use of counterfeit and/or "grey market" parts not made, supplied or approved by Generac.
You are responsible for contacting a Generac Authorized Warranty Dealer as soon as a problem occurs. The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.
Warranty service can be arranged by contacting either your selling dealer or a Generac Authorized Warranty Service Dealer. To locate the Generac Authorized Warranty Service Dealer nearest you, call our toll free number:
IMPORTANT NOTE: This warranty statement explains your rights and obligations under the Emission Control System Warranty (ECS Warranty), which is provided to you by Generac pursuant to federal law. See also the "Generac Limited Warranties for Generac Power Systems, Inc.," which is enclosed herewith on a separate sheet, also provided to you by Generac. Note that this warranty shall not apply to any incidental, consequential or indirect damages caused by defects in materials or workmanship or any delay in repair or replacement of the defective part(s). This warranty is in place of all other warranties, expressed or implied. Specifically, Generac makes no other warranties as to the merchantability or fitness for a particular purpose. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
The ECS Warranty applies only to the emission control system of your new equipment. If there is any conflict in terms between the ECS Warranty and the Generac Warranty, the Generac Warranty shall apply. Both the ECS Warranty and the Generac Warranty describe important rights and obligations with respect to your new engine.
Warranty service can be performed only by a Generac Authorized Warranty Service Facility. When requesting warranty service, evidence must be presented showing the date of the sale to the original purchaser/owner.
If you have any questions regarding your warranty rights and responsibilities, you should contact Generac at the following address:
GENERAC POWER SYSTEMS, INC. P.O. BOX 297 • WHITEWATER, WI 53190
Part No. 0H1913 Rev. A 08/09 Part 1

EMISSION CONTROL SYSTEM WARRANTY
Emission Control System Warranty (ECS warranty) for equipment using small spark-ignited engines:
(a) Applicability: This warranty shall apply to equipment that uses small off-road engines. The ECS Warranty period shall begin
on the date the new equipment is purchased by/delivered to its original, end-use purchaser/owner and shall continue for 24 consecutive months thereafter.
equipment and to each subsequent purchaser/owner that the ECS when installed was: (1) Designed, built and equipped so as to conform with all applicable regulations; and (2) Free from defects in materials and workmanship which cause the failure of a warranted part at any time during the ECS
Warranty Period.
(c) The warranty on emissions-related parts will be interpreted as follows: (1) Any warranted part that is not scheduled for replacement as required maintenance in the Owner's Manual shall be
warranted for the ECS Warranty Period. If any such part fails during the ECS Warranty Period, it shall be repaired or replaced by Generac according to Subsection (4) below. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period. (2) Any warranted part that is scheduled only for regular inspection as specified in the Owner's Manual shall be warranted
for the ECS Warranty Period. A statement in the Owner’s Manual to the effect of "repair or replace as necessary" shall not reduce the ECS Warranty Period. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period. (3) Any warranted part that is scheduled for replacement as required maintenance in the Owner's Manual shall be warranted
for the period of time prior to first scheduled replacement point for that part. If the part fails prior to the first scheduled replacement, the part shall be repaired or replaced by Generac according to Subsection (4) below. Any such emissions- related part repaired or replaced under the ECS warranty shall be warranted for the remainder of the period prior to the first scheduled replacement point for that part. (4) Repair or replacement of any warranted, emissions-related part under this ECS Warranty shall be performed at no charge
to the owner at a Generac Authorized Warranty Service Facility. (5) Notwithstanding the provisions of subsection (4) above, warranty services or repairs must be provided at Generac
Authorized Service Facilities. (6) When the engine is inspected by a Generac Authorized Warranty Service Facility, the purchaser/owner shall not be held
responsible for diagnostic costs if the repair is deemed warrantable. (7) Throughout the ECS Warranty Period, Generac shall maintain a supply of warranted emission-related parts sufficient to
meet the expected demand for such parts. (8) Any Generac authorized and approved emission-related replacement parts may be used in the performance of any ECS
warranty maintenance or repairs and will be provided without charge to the purchaser/owner. Such use shall not reduce Generac ECS Warranty obligations. (9) Unapproved, add-on, modified, counterfeit and/or "grey market" parts may not be used to modify or repair a Generac
engine. Such use voids this ECS Warranty and shall be sufficient grounds for disallowing an ECS Warranty claim. Generac shall not be held liable hereunder for failures of any warranted parts of Generac equipment caused by the use of such an unapproved, add-on, modified, counterfeit and/or "grey market" part.
*NOTE: As they relate to the Emission Control System.
Part No. 0H1913 Rev. A ??/?? Part 2

GENERAC POWER SYSTEMS “TWO YEAR” LIMITED WARRANTY FOR
GP SERIES PORTABLE GENERATORS
For a period of two years from the date of original sale, Generac Power Systems, Inc. (Generac) warrants its GP Series generators will be free from defects in materials and workmanship for the items and period set forth below. Generac will, at its option, repair or replace any part which, upon examination, inspection and testing by Generac or a Generac Authorized Warranty Service Dealer, is found to be defective. Any equipment that the purchaser/owner claims to be defective must be returned to and examined by the nearest Generac Authorized Warranty Service Dealer. All transportation costs under the warranty, including return to the factory, are to be borne and prepaid by the purchaser/owner. This warranty applies only to Generac GP Series portable generators and is not transferable from original purchaser. Save your proof-of-purchase receipt. If you do not provide proof of the initial purchase date, the manufacturer’s shipping date of the product will be used to determine the warranty period.
Consumer applications are warranted for two (2) years. Commercial and Rental applications are warranted for one (1) year or 1000 hours maximum, whichever comes first.
used for Prime Power in place of utility where utility power service is present or where utility power service does not normally exist. Once a generator has experienced commercial or rental use, it shall thereafter be considered a non-consumer use generator for the purpose of this warranty.
All warranty expense allowances are subject to the conditions defined in Generac’s Warranty Policies, Procedures and Flat Rate Manual.
THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. SPECIFICALLY, GENERAC MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. GENERAC’S ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC’S NEGLIGENCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights. You also have other rights from state to state.
Part No. 0H3172 Revision A (05/15/09) Printed in China
Manual Part No. 0H2379 Rev A (08/04/09) Printed in China

MODELO: 005789-0


LIMITADA
2 AÑOS
ASISTENCIA DE CONCESIONARIOS
AUTORIZADOS:
www.generac.com
o 1-888-GENERAC
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Engine is running, but no AC output is available. | 1. Circuit breaker is open. 2. Poor connection or defective cord set. 3. Connected device is bad. 4. Fault in generator. | 1. Reset circuit breaker. 2. Check and repair. 3. Connect another device that is in good condition. 4. Contact Authorized Service Facility. | p.14 |
| Engine is running, but no AC output is available. | p.14 | ||
| Engine runs good but bogs down when loads are connected. | 1. Short circuit in a connected load. 2. Generator is overloaded. 3. Engine speed is too slow. 4. Shorted generator circuit. | 1. Disconnect shorted electrical load. 2. See “Don’t Overload the Generator” . 3. Contact Authorized Service Facility. 4. Contact Authorized Service Facility. | p.14 |
| Engine runs good but bogs down when loads are connected. | p.14 | ||
| Engine will not start; or starts and runs rough. | 1. Dirty air filter. 2. Out of gasoline. 3. Stale gasoline. 4. Spark plug wire not connected to spark plug. 5. Bad spark plug. 6. Water in gasoline. 7. Over-choking. 8. Low oil level. 9. Excessive rich fuel mixture. 10. Intake valve stuck open or closed. 11. Engine has lost compression. | 1. Clean or replace air filter. 2. Fill fuel tank. 3. Drain fuel tank and fill with fresh fuel. 4. Connect wire to spark plug. 5. Replace spark plug. 6. Drain fuel tank; fill with fresh fuel. 7. Put choke knob to No Choke position. 8. Fill crankcase to proper level. 9. Contact Authorized Service Facility. 10. Contact Authorized Service Facility. 11. Contact Authorized Service Facility. | p.14 |
| Engine will not start; or starts and runs rough. | p.14 | ||
| Engine shuts down during operation. | 1. Out of gasoline. 2. Low oil level. 3. Fault in engine. | 1. Fill fuel tank. 2. Fill crankcase to proper level. 3. Contact Authorized Service Facility. | p.14 |
| Engine shuts down during operation. | p.14 | ||
| Engine lacks power. | 1. Load is too high. 2. Dirty air filter. 3. Engine needs to be serviced. | 1. See “Don’t Overload the Generator”. 2. Replace air filter. 3. Contact Authorized Service Facility. | p.14 |
| Engine lacks power. | p.14 | ||
| Engine “hunts” or falters. | 1. Choke is opened too soon. 2. Carburetor is running too rich or too lean. | 1. Move choke to halfway position until engine runs smoothly. 2. Contact Authorized Service Facility. | p.14 |
| 14 | p.16 |