005735-0 (17,500 Watt)
Owner's Manual GP Series Portable Generator

DEADLY EXHAUST FUMES! ONLY use OUTSIDE far away from windows, doors and vents!
NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS.
SAVE this Manual. Provide this manual to any operator of the generator.



INTRODUCTION Thank you for purchasing this model by Generac Power Systems, Inc. This model is a compact, high performance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads where no utility power is available or in place of utility due to a power outage.
These safety warnings cannot eliminate the hazards that they indicate. Common sense and strict compliance with the special instructions while performing the action or service are essential to preventing accidents.
READ THIS MANUAL THOROUGHLY If any portion of this manual is not understood, contact the nearest Authorized Dealer for starting, operating and servicing procedures.
Four commonly used safety symbols accompany the DANGER, WARNING and CAUTION blocks. The type of information each indicates is as follows:
This symbol points out important safety information that, if not followed, could endanger personal safety and/or property of others.
The operator is responsible for proper and safe use of the equipment. We strongly recommend that the operator read this manual and thoroughly understand all instructions before using the equipment. We also strongly recommend instructing other users to properly start and operate the unit. This prepares them if they need to operate the equipment in an emergency.
This symbol points out potential explosion hazard.
This symbol points out potential fire hazard.
The generator can operate safely, efficiently and reliably only if it is properly located, operated and maintained. Before operating or servicing the generator:
This symbol points out potential electrical shock hazard.
The manufacturer cannot anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and on tags and decals affixed to the unit are, therefore, not all inclusive. If using a procedure, work method or operating technique that the manufacturer does not specifically recommend, ensure that it is safe for others. Also make sure the procedure, work method or operating technique utilized does not render the generator unsafe.
THE INFORMATION CONTAINED HEREIN WAS BASED ON MACHINES IN PRODUCTION AT THE TIME OF PUBLICATION. GENERAC RESERVES THE RIGHT TO MODIFY THIS MANUAL AT ANY TIME.
SAFETY RULES Throughout this publication, and on tags and decals affixed to the generator, DANGER, WARNING, CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular operation that may be hazardous if performed incorrectly or carelessly. Observe them carefully. Their definitions are as follows:
Indicates a hazardous situation or action which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation or action which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation or action which, if not avoided, could result in minor or moderate injury.

SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted near the unit's installation site. Safety should be stressed to all operators and potential operators of this equipment.
ELECTRICAL HAZARDS


MODEL NO:
In the absence of pertinent standards, codes, regulations and laws, the published information listed below may be used as a guideline for operation of this equipment. Always reference the latest revision available for the standards listed.

CALIFORNIA PROPOSITION 65 WARNING Engine exhaust and some of its constituents are known
to the State of California to cause cancer, birth defects
and other reproductive harm.
CALIFORNIA PROPOSITION 65 WARNING This product contains or emits chemicals known to the
State of California to cause cancer, birth defects and
other reproductive harm.
ID Plate

1.1 UNPACKING • Set the palleted carton on a rigid flat surface.
1.2 ASSEMBLY The generator requires some assembly prior to using it. If problems arise when assembling the generator, please call the Generator Helpline at 1-888-436-3722.
The wheel kit is designed to greatly improve the portability of the generator. A socket wrench with a 9/16” socket, a 1/2” socket, a 1/2” wrench and a pair of pliers are the tools that will be needed for assembly of the wheel kit.

The wheel kit is not intended for over-the-road use.
Check all contents. If any parts are missing or damaged locate an authorized dealer at 1-888-436-3722.
Contents include:


Figure 3 - Battery Connections

Negative
Cable
Cable
A battery may lose some of it’s charge when not in use for prolonged periods of time.

2.1 KNOW THE GENERATOR Read the Owner’s Manual and Safety Rules before operating this generator.
12. Grounding Lug – Ground the generator to an approved earth ground here. See "Grounding the Generator" for details. 13. Idle Control Switch – The idle control runs the engine at normal (high) speeds when there is an electrical load present and runs the engine at idle (low) speeds when a load is not present. 14. Start/Run/Stop Switch – Controls the operation of the generator. 15. Oil Fill – Use this point to add oil to engine. 16. Fuse - 10 Amp (Located at rear of control panel) – Protects the DC control circuit from overload. If this fuse element has melted open the engine will not be able to crank and start. 17. Hourmeter - Tracks hours of operation.
Compare the generator to Figures 4 through 7 to become familiarized with the locations of various controls and adjustments. Save this manual for future reference.
1. 12 Volt DC, 10 Amp Receptacle – This receptacle allows the capability to recharge a 12 volt DC storage battery with provided battery charge cables. 2. 120 Volt AC, 20 Amp, Duplex Receptacle – Supplies electrical power for the operation of 120 Volt AC, 20 Amp, single-phase, 60 Hz electrical lighting, appliance, tool and motor loads. 3. 120 Volt AC, 20A Duplex GFCI Receptacle – Supplies ground fault protected electrical power for operation of 120 volt AC 20 amp, single-phase, 60 Hz electric lighting, appliances, tools and motor loads. 4. 120 Volt AC, 30 Amp Locking Receptacle – Supplies electrical power for the operation of 120 Volt AC, 30 Amp, single-phase, 60 Hz electrical lighting, appliance, tool and motor loads. 5. 120/240 Volt AC, 30 Amp Locking Receptacle – Supplies electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single- phase, 60 Hz, electrical lighting, appliance, tool and motor loads. 6. 120/240 Volt AC, 50 Amp Receptacle (17.5kW, Located on underside of control panel)– Supplies electrical power for the operation of 120/240 Volt AC, 50 Amp, single-phase, 60 Hz, welder or motor loads. 7. Air Cleaner – Filters intake air as it is drawn into the engine. 8. Choke Knob – Used when starting a cold engine. 9. Winter/Summer Valve – See “Cold Weather Operation/De-icer” section. 10. Circuit Breakers (AC) – Each receptacle is provided with a push- to-reset circuit breaker to protect the generator against electrical overload. (50 amp uses toggle reset) 11. Fuel Tank – Tank holds 16 U.S. gallons of fuel.




Figure 8 - 120 Volt AC, 20 Amp, Duplex Receptacle

This unit is equipped with a ground fault circuit interrupter (GFCI). This device meets applicable federal, state and local codes (Figure 9).
There will be a one time break in "CHG OIL" message that flashes with the elapsed time in hours and tenths after the first 30 hours of operation.
A GFCI receptacle is different from conventional receptacles. In the event of a ground fault, a GFCI will trip and quickly stop the flow of electricity to prevent serious injury.
This message will actually begin flashing at 29 hours and disable itself at 31 hours providing a two hour window to perform the service.
Definition: Instead of following its normal safe path, electricity passes through a persons body to reach the ground. For example, a defective appliance can cause a ground fault.
There will be a subsequent "CHG OIL" message every 100 hours. The message will flash one hour before and one hour after each 100 hour interval, again providing a two hour window to perform service.
Every 200 hours the "SVC" icon on the lower left hand corner of the display will flash. The message will flash one hour before and one hour after each 200 hour interval providing a two hour window to perform service.
A GFCI receptacle does NOT protect against circuit overloads, short circuits, or shocks. For example, electric shock can still occur if a person touches charged electrical wires while standing on a non-conducting surface, such as a wood floor.
When the hour meter is in the Flash Alert mode, the maintenance message will always alternate with elapsed time in hours and tenths. The hours will flash four times, then alternate with the maintenance message four times until the meter resets itself.

This is a 120 Volt outlet protected against overload by a 20 Amp push- to-reset circuit breaker (Figure 8). Use each socket to power 120 Volt AC, single phase, 60 Hz electrical loads requiring up to a combined 2400 watts (2.4 kW) or 20 Amps of current. Use only high quality, well- insulated, 3-wire grounded cord sets rated for 125 Volts at 20 Amps (or greater).
Keep extension cords as short as possible, preferably less than 15 feet long, to prevent voltage drop and possible overheating of wires.

Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps or 240 Volt AC, 60 Hz, single phase loads requiring up to 7200 watts (7.2 kW) of power at 30 Amps. The outlet is protected by two 30 Amp push-to-reset circuit breakers.
This receptacle permits recharging a 12-Volt automotive or utility style storage battery with the battery charge cables provided (Figure 12). This receptacle can not recharge 6-Volt batteries and can not be used to crank an engine having a discharged battery. See the section "Charging a Battery" before attempting to recharge a battery.
2.3.3 120 VAC, 30 AMP RECEPTACLE
Use a NEMA L5-30 plug with this receptacle. Connect a 3-wire cord set rated for 125 Volts AC at 30 Amps (or greater) to the plug (Figure 10).
2.3.6 120/240 VAC, 50 AMP RECEPTACLE
Use a NEMA 14-50 plug with this receptacle. Connect a 4-wire cord set rated for 250 Volts AC at 50 Amps to the plug (Figure 13).
Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps. The outlet is protected by a 30 Amp push-to-reset circuit breaker.
Use a NEMA L14-30 plug with this receptacle. Connect a suitable 4-wire grounded cord set to the plug and to the desired load. The cord set should be rated for 250 Volts AC at 30 Amps (or greater) (Figure 11).
Figure 11 - 120/240 VAC, 30 Amp Receptacle
Use this receptacle to operate 120/240 Volt AC, 60 Hz electrical loads requiring up to 12,000 watts (12.0 kW) of power. This receptacle is protected by a 50 Amp 2-pole circuit breaker.

2.4 HOW TO USE THE GENERATOR If there are any problems operating the generator, please call the generator helpline at 1-888-436-3722.
2.5 DON’T OVERLOAD THE GENERATOR Overloading a generator in excess of its rated wattage capacity can result in damage to the generator and to connected electrical devices. Observe the following to prevent overloading the unit:
The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground (Figure 14). Local electrical codes may also require proper grounding of the unit. For that purpose, generally, connecting a No. 10 AWG (American Wire Gauge) stranded copper wire to the grounding wing nut and to an earth-driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. However, local codes may vary widely. Consult with a local electrician for grounding requirements in the area.

The Wattage Reference Guide is provided to assist in determining how many items the generator can operate at one time.
Device Running Watts *Air Conditioner (12,000 Btu) 1700 *Air Conditioner (24,000 Btu) 3800 *Air Conditioner (40,000 Btu) 6000 Battery Charger (20 Amp) 500 Belt Sander (3") 1000 Chain Saw 1200 Circular Saw (6-1/2") 800 to 1000 *Clothes Dryer (Electric) 5750 *Clothes Dryer (Gas) 700 *Clothes Washer 1150 Coffee Maker 1750 *Compressor (1 HP) 2000 *Compressor (3/4 HP) 1800 *Compressor (1/2 HP) 1400 Curling Iron 700 *Dehumidifier 650 Disc Sander (9") 1200 Edge Trimmer 500 Electric Blanket 400 Electric Nail Gun 1200 Electric Range (per element) 1500 Electric Skillet 1250 *Freezer 700 *Furnace Fan (3/5 HP) 875 *Garage Door Opener 500 to 750 Hair Dryer 1200 Hand Drill 250 to 1100 Hedge Trimmer 450 Impact Wrench 500 Iron 1200 *Jet Pump 800
Proper grounding of the generator will help prevent electrical shock in the event of a ground fault condition in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices.
DO NOT connect 240 Volt loads to 120 Volt receptacles. DO NOT connect 3-phase loads to the generator. DO NOT connect 50 Hz loads to the generator.
Generator Ground Lug

Lawn Mower 1200 Light Bulb 100 Microwave Oven 700 to 1000 *Milk Cooler 1100 Oil Burner on Furnace 300 Oil Fired Space Heater (140,000 Btu) 400 Oil Fired Space Heater (85,000 Btu) 225 Oil Fired Space Heater (30,000 Btu) 150 *Paint Sprayer, Airless (1/3 HP) 600 Paint Sprayer, Airless (handheld) 150 Radio 50 to 200 *Refrigerator 700 Slow Cooker 200 *Submersible Pump (1-1/2 HP) 2800 *Submersible Pump (1 HP) 2000 *Submersible Pump (1/2 HP) 1500 *Sump Pump 800 to 1050 *Table Saw (10") 1750 to 2000 Television 200 to 500 Toaster 1000 to 1650 Weed Trimmer 500 * Allow 3 times the listed watts for starting these devices.
Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Allow unit/engine to cool entirely before adding fuel. DO NOT light a cigarette or smoke when filling the fuel tank.
Do not overfill the fuel tank. Always leave room for fuel expansion.
2.7 BEFORE STARTING THE GENERATOR Prior to operating the generator, engine oil and gasoline will need to be added, as follows:
All oil should meet minimum American Petroleum Institute (API) Service Class SJ, SL or better. Use no special additives. Select the oil's viscosity grade according to the expected operating temperature (also see chart).
Any attempt to crank or start the engine before it has been properly serviced with the recommended oil may result in an engine failure.
IMPORTANT: It is important to prevent gum deposits from forming in fuel system parts such as the carburetor, fuel hose or tank during storage. Alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage. To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. See the "Storage" section. Never use engine or carburetor cleaner products in the fuel tank as permanent damage may occur.
Synthetic 5W-30

The manufacturer does not recommend using any gasoline containing alcohol (such as “gasohol”). If using any gasoline containing alcohol, it must not contain more than 10 percent ethanol, and it must be removed from the generator during storage. Do NOT use any gasoline containing methanol. If using gasoline with alcohol, inspect more frequently for fuel leaks and other abnormalities.
2.8 TO START THE ENGINE
Never start or stop engine with electrical devices plugged into the receptacles AND devices turned on.

Never operate in an enclosed area or indoors! NEVER use in the home, or in partly enclosed areas such as garages, even if doors and windows are open! ONLY use outdoors and far from open windows, doors, vents, and in an area that will not accumulate deadly exhaust.

If engine fires, but does not continue to run, move choke lever to “Full Choke” and repeat starting instructions.

2.9 STOPPING THE ENGINE • Shut off all loads, then unplug the electrical loads from generator panel receptacles. Never start or stop the engine with electrical devices plugged in and turned on.
Storage batteries give off explosive hydrogen gas while recharging. An explosive mixture will remain around the battery for a long time after it has been charged. The slightest spark can ignite the hydrogen and cause an explosion. Such an explosion can shatter the battery and cause blindness or other serious injury.
2.10 AUTOMATIC IDLE CONTROL This feature is designed to greatly improve fuel economy. When this switch is turned “On,” the engine will only run at its normal fast governed engine speed when electrical load is connected. When the load is removed, the engine will run at a reduced speed of 2100 RPM. With the switch “Off,” the engine runs at the normal fast engine speed all the time. Always have the switch OFF when starting and stopping the engine.
Do not permit smoking, open flame, sparks or any other source of heat around a battery. Wear protective goggles, rubber apron and rubber gloves when working around a battery. Battery electrolyte fluid is an extremely caustic sulfuric acid solution that can cause severe burns. If spill occurs flush area with clear water immediately.
2.11 COLD WEATHER OPERATION/DE-ICER Under certain weather conditions (temperatures below 40° F (4° C) and a high dew point), the engine may experience icing of the carburetor and/or the crankcase breather system. To eliminate this problem, this generator engine is fitted with a winter/summer valve. This directs hot air into the carburetor during cold weather operation. Always make sure the winter/ summer valve is in the correct location relative to the weather conditions.
This generator has the capability of recharging a discharged 12 Volt automotive or utility style storage battery. Do not use the unit to charge any 6 Volt batteries. Do not use the unit to crank an engine having a discharged battery.
This battery charger is a pulse type designed to provide a quality charge current into the battery. The voltage measured at the outlet should be 8-12 VDC. This is normal and does not indicate a faulty charging system.
To recharge 12 Volt batteries, proceed as follows:
2.12 LOW OIL PRESSURE SHUTDOWN SYSTEM The engine is equipped with a low oil pressure sensor that shuts down the engine automatically when the oil pressure drops below 10 psi. If the engine shuts down by itself and the fuel tank has enough gasoline, check engine oil level.
A delay built into the low oil shutdown system allows oil pressure to build during starting. The delay allows the engine to run for about 10 seconds before sensing oil pressure.
If the system senses low oil pressure during operation, the engine shuts down.
Use an automotive hydrometer to test battery state of charge and condition. Follow the hydrometer manufacturer's instructions carefully. Generally, a battery is considered to be at 100% state of charge when specific gravity of its fluid (as measured by hydrometer) is 1.260 or higher.
If trying to restart the engine within 10 seconds after it shuts down, the engine may NOT start. The system needs five (5) to 10 seconds to reset.
If the engine is restarted after such a shutdown and the low oil pressure has not been corrected, the engine will run for about 10 seconds as described above and then stop.

3.1 PERFORMING SCHEDULED MAINTENANCE It is important to perform service as specified in the Maintenance Schedule for proper generator operation, and to ensure that the generator complies with the applicable emission standards for the duration of its useful life. Service and repairs may be performed by any capable person or repair shop. Additionally, emissions critical maintenance must be performed as scheduled in order for the Emissions Warranty to be valid. Emissions critical maintenance consists of servicing the air filter and spark plugs in accordance with the Maintenance Schedule.

Oil Type Summer – SAE 30, Winter – 5W-30 Synthetic or 10W-30
Oil Capacity w/ Filter Change = 1.7 Qts., w/o Filter Change = 1.4 Qts.
3.2 MAINTENANCE SCHEDULE Follow the calendar intervals. More frequent service is required when operating in adverse conditions noted below.
Check Oil Level At Each Use Change Oil ‡ *Every 100 hours or Every Season Check Valve Clearance ***Every Season Service Air Filter ** Every 200 hours or Every Season Replace Spark Plug Every Season
The Environmental Protection Agency (and California Air Resource Board for generators certified to CA standards) require(s) that this generator comply with exhaust and evaporative emission standards. Locate the emissions compliance decal on the engine to determine what standards the generator meets. This generator is certified to operate on gasoline. The emission control system consists of the following:
‡ Change oil after first 30 hours of operation then every season. * Change oil and oil filter every month when operating under heavy load or in high temperatures. ** Clean more often under dirty or dusty operating conditions. Replace air filter parts if they cannot be adequately cleaned. *** Check valve clearance and adjust if necessary after first 50 hours of operation and every 100 hours thereafter.

3.4 GENERAL RECOMMENDATIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.
Rated Frequency 60 Hz @ 3600 RPM 60 Hz @ 3600 RPM
Some adjustments will need to be made periodically to properly maintain the generator.
All adjustments in the Maintenance section of this manual should be made at least once each season. Follow the requirements in the "Maintenance Schedule" chart.
Once a year, replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help the engine run better and last longer.

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material.
Whenever possible, run engine for approximately five (5) minutes to get the engine oil hot. This will aid in draining the oil.
Use the following instructions to change the oil while the engine is still warm:
Check the cleanliness of the generator frequently and clean when dust, dirt, oil, moisture or other foreign substances are visible on its exterior surface.
Never insert any object or tool through the air cooling slots, even if the engine is not running.
DO NOT use a garden hose to clean generator. Water can enter the engine fuel system and cause problems. In addition, if water enters the generator through cooling air slots, some water will be retained in voids and crevices of the rotor and stator winding insulation. Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.
3.4.2 TO CLEAN THE GENERATOR
Use Champion RC14YC spark plug or equivalent. The correct air gap is 1.01 mm (0.040 in.). Replace the plugs once each year. This will help the engine start easier and run better.
Figure 19 - Spark Plug Gap

When working on the generator, always disconnect negative cable from battery. Also disconnect spark plug wires from spark plugs and keep wire away from spark plugs.
See the “BEFORE STARTING THE GENERATOR” section for information on checking the oil level. The oil level should be checked before each use, or at least every eight hours of operation. Keep the oil level maintained.
3.5 SERVICE AIR CLEANER The engine will not run properly and may be damaged if using a dirty air cleaner. Clean or replace the air cleaner paper filter every 200 hours. Clean or replace more often if operating under dusty conditions. Clean foam pre- cleaner every month or more often under dusty conditions.
Hot oil may cause burns. Allow engine to cool before draining oil. Avoid prolonged or repeated skin exposure with used oil. Thoroughly wash exposed areas with soap.
To clean or replace foam pre-cleaner:
Change the oil and filter after the first 30 hours of operation. Change the oil every 100 hours thereafter. If running this unit under dirty or dusty conditions, or in extremely hot weather, change the oil more often.

To clean or replace paper air filter:

To order a new air filter, please contact the nearest authorized service center at 1-800-333-1322.

3.7 ADJUSTING VALVE CLEARANCE After the first 50 hours of operation, check the valve clearance in the engine and adjust if necessary.
To check valve clearance:
3.6 CLEAN SPARK ARRESTOR SCREEN The engine exhaust muffler has a spark arrestor screen. Inspect and clean the screen at least once each year (Figure 20). If unit is used regularly, inspect and clean more often.
If using the generator on any forest-covered, brush-covered or grass- covered unimproved land, it must equipped with a spark arrestor. The spark arrestor must be maintained in good condition by the owner/ operator.
Clean and inspect the spark arrestor as follows:
To adjust valve clearance:
The rocker arm jam nut must be held in place as the pivot ball stud is turned.

3.9 LONG TERM STORAGE
It is important to prevent gum deposits from forming in essential fuel system parts such as the carburetor, fuel hose or tank during storage. Also, experience indicates that alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage.

To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer, as follows:
Drain fuel into approved container outdoors, away from open flame. Be sure engine is cool. Do not smoke.
When valve clearance is correct, hold the pivot ball stud in place with the allen wrench and tighten the rocker arm jam nut. Tighten the jam nut to 174 in/lbs. torque. After tightening the jam nut, recheck valve clearance to make sure it did not change.
Start all four screws before tightening or it will not be possible to get all the screws in place. Make sure the valve cover gasket is in place.
Avoid spray from spark plug holes when cranking engine.
The generator should be started at least once every seven days and be allowed to run at least 30 minutes. If this cannot be done and the unit must be stored for more than 30 days, use the following information as a guide to prepare it for storage.
3.10 OTHER STORAGE TIPS • Do not store gasoline from one season to another.
NEVER store engine with fuel in tank indoors or in enclosed, poorly ventilated areas where fumes may reach an open flame, spark or pilot light as on a furnace, water heater, clothes dryer or other gas appliance.
NEVER cover the generator while engine and/or exhaust area are warm.

4.1 TROUBLESHOOTING GUIDE
Engine is running, but no AC output is available.
Engine runs good but bogs down when loads are connected.
Engine will not crank. 1. 10 amp fuse at rear of generator control panel has melted open. 2. Battery weak or dead.
Engine will not start; or starts and runs rough.
Engine shuts down during operation.
Engine lacks power. 1. Load is too high. 2. Dirty air filter. 3. Engine needs to be serviced.
Engine “hunts” or falters. 1. Choke is opened too soon. 2. Carburetor is running too rich or too lean. 1. Move choke to halfway position until engine runs smoothly. 2. Contact Authorized Service Facility.
No Battery Charge DC output.



YOUR WARRANTY RIGHTS AND OBLIGATIONS
The United States Environmental Protection Agency (EPA) and Generac Power Systems, Inc. (Generac) are pleased to explain the Emission Control System Warranty (ECS Warranty) on your new 2011 and later equipment. New equipment that use small spark-ignited engines must be designed, built, and equipped to meet stringent anti-smog standards for the federal government. Generac will warrant the emission control system on your equipment for the period of time listed below provided there has been no abuse, neglect, unapproved modification or improper maintenance of your equipment. The emission control system on this equipment includes all components whose failure would increase the emissions of any regulated pollutant. These components are listed in the Emissions Information section of this manual.
MANUFACTURER’S WARRANTY COVERAGE: This ECS Warranty is valid for two years, or for the same period as specified in the Generac Limited Warranty, whichever is longer. For equipment with hour meters, the warranty period is a number of hours equal to half the Useful Life to which the equipment is certified, or the warranty period specified above in years, whichever is less. The Useful Life can be found on the Emission Control Label on the engine. If, during such warranty period, any emission-related part on your equipment is found to be defective in materials or workmanship, repairs or replacement will be performed by a Generac Authorized Warranty Service Dealer.
As the equipment owner, you are responsible for the completion of all required maintenance as listed in your factory supplied Owner's Manual. For warranty purposes, Generac recommends that you retain all receipts covering maintenance on your generator, but Generac cannot deny warranty solely due to the lack of receipts.
You should be aware that Generac may deny any and/or all warranty coverage or responsibility if your equipment, or a part/component thereof, has failed due to abuse, neglect, improper maintenance, or unapproved modifications.
You are responsible for contacting a Generac Authorized Warranty Dealer as soon as a problem occurs. The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.
Warranty service can be arranged by contacting either your selling dealer or a Generac Authorized Warranty Service Dealer. To locate the Generac Authorized Warranty Service Dealer nearest you, call our toll free number below, or email emissions@generac.com.
IMPORTANT NOTE: This warranty statement explains your rights and obligations under the Emission Control System Warranty, which is provided to you by Generac pursuant to federal law. See also the "Generac Limited Warranties for Generac Power Systems, Inc.," which is enclosed herewith on a separate sheet, also provided to you by Generac. Note that this warranty shall not apply to any incidental, consequential or indirect damages caused by defects in materials or workmanship or any delay in repair or replacement of the defective part(s). This warranty is in place of all other warranties, expressed or implied. Specifically, Generac makes no other warranties as to the merchantability or fitness for a particular purpose. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
The ECS Warranty applies only to the emission control system of your new equipment. Both the ECS Warranty and the Generac Warranty describe important rights and obligations with respect to your new engine.
Warranty service can be performed only by a Generac Authorized Warranty Service Facility. When requesting warranty service, evidence must be presented showing the date of the sale to the original purchaser/owner.
If you have any questions regarding your warranty rights and responsibilities, you should contact Generac at the following address:
GENERAC POWER SYSTEMS, INC. P.O. BOX 297 • WHITEWATER, WI 53190
Part No. 0J3335 Rev. A 12/10
Part 1

Emission Control System Warranty (ECS Warranty) for equipment using small spark-ignited engines:
(a) Applicability: This warranty shall apply to equipment that uses small off-road engines. The ECS Warranty period shall begin on the date the new
equipment is purchased by/delivered to its original, end-use purchaser/owner and shall continue for the lesser of: (1) The period of time specified in the Generac Limited Warranty enclosed herewith, but not less than 24 months, or (2) For engines equipped with hour meters, a number of operating hours equal to half of the engine’s useful life. The useful life is specified on the
Emissions Control Label on the engine.
(b) General Emissions Warranty Coverage: Generac warrants to the original, end-use purchaser/owner of the new engine or equipment and to each
subsequent purchaser/owner that the ECS when installed was: (1) Designed, built and equipped so as to conform with all applicable regulations; and (2) Free from defects in materials and workmanship which cause the failure of a warranted part at any time during the ECS Warranty Period.
(c) The warranty on emissions-related parts will be interpreted as follows: (1) Any warranted part that is not scheduled for replacement as required maintenance in the Owner's Manual shall be warranted for the ECS
Warranty Period. If any such part fails during the ECS Warranty Period, it shall be repaired or replaced by Generac according to Subsection (4) below. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period. (2) Any warranted part that is scheduled only for regular inspection as specified in the Owner's Manual shall be warranted for the ECS Warranty
Period. A statement in the Owner’s Manual to the effect of "repair or replace as necessary" shall not reduce the ECS Warranty Period. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period. (3) Any warranted part that is scheduled for replacement as required maintenance in the Owner's Manual shall be warranted for the period of time
prior to first scheduled replacement point for that part. If the part fails prior to the first scheduled replacement, the part shall be repaired or replaced by Generac according to Subsection (4) below. Any such emissions-related part repaired or replaced under the ECS warranty shall be warranted for the remainder of the period prior to the first scheduled replacement point for that part. (4) Repair or replacement of any warranted, emissions-related part under this ECS Warranty shall be performed at no charge to the owner at a
Generac Authorized Warranty Service Facility. (5) Notwithstanding the provisions of subsection (4) above, warranty services or repairs must be provided at Generac Authorized Service Facilities. (6) When the engine is inspected by a Generac Authorized Warranty Service Facility, the purchaser/owner shall not be held responsible for
diagnostic costs if the repair is deemed warrantable. (7) Throughout the ECS Warranty Period, Generac shall maintain a supply of warranted emission-related parts sufficient to meet the expected
demand for such parts. (8) Any Generac authorized and approved emission-related replacement parts may be used in the performance of any ECS Warranty maintenance or
repairs and will be provided without charge to the purchaser/owner. Such use shall not reduce Generac ECS Warranty obligations. (9) No modifications, other than those explicitly approved by Generac, may be made to the generator. Unapproved modifications void this ECS
Warranty and shall be sufficient ground for disallowing an ECS Warranty claim. (10) Generac shall not be held liable hereunder for failures of any non-authorized replacement parts, or failures of any authorized parts caused by the
use of non-authorized replacement parts.
Part No. 0J3335 Rev. A 12/10
Part 2

GP SERIES PORTABLE GENERATORS
For a period of two years from the date of original sale, Generac Power Systems, Inc. (Generac) warrants its GP Series generators will be free from defects in materials and workmanship for the items and period set forth below. Generac will, at its option, repair or replace any part which, upon examination, inspection and testing by Generac or a Generac Authorized Warranty Service Dealer, is found to be defective. Any equipment that the purchaser/owner claims to be defective must be returned to and examined by the nearest Generac Authorized Warranty Service Dealer. All transportation costs under the warranty, including return to the factory, are to be borne and prepaid by the purchaser/owner. This warranty applies only to Generac GP Series portable generators and is not transferable from original purchaser. Save your proof-of-purchase receipt. If you do not provide proof of the initial purchase date, the manufacturer’s shipping date of the product will be used to determine the warranty period.
Consumer applications are warranted for two (2) years. Commercial and Rental applications are warranted for one (1) year or 1000 hours maximum, whichever comes first.
used for Prime Power in place of utility where utility power service is present or where utility power service does not normally exist. Once a generator has experienced commercial or rental use, it shall thereafter be considered a non-consumer use generator for the purpose of this warranty.
All warranty expense allowances are subject to the conditions defined in Generac’s Warranty Policies, Procedures and Flat Rate Manual.
THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. SPECIFICALLY, GENERAC MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Any implied warranties allowed by law shall be limited in duration to the terms of the express warranty provided herein. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. GENERAC’S ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC’S NEGLIGENCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights. You also have other rights from state to state.
Part No. 0H0676 Rev. D (06/07/11) Printed in U.S.A.
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| 10 | p.12 | ||
| Engine is running, but no AC output is available. | 1. Circuit breaker is open. 2. Poor connection or defective cord set. 3. Connected device is bad. 4. Fault in generator. | 1. Reset circuit breaker. 2. Check and repair. 3. Connect another device that is in good condition. 4. Contact Authorized Service Facility. | p.19 |
| Engine is running, but no AC output is available. | p.19 | ||
| Engine runs good but bogs down when loads are connected. | 1. Short circuit in a connected load. 2. Generator is overloaded. 3. Engine speed is too slow. 4. Shorted generator circuit. | 1. Disconnect shorted electrical load. 2. See “Don’t Overload the Generator” . 3. Contact Authorized Service Facility. 4. Contact Authorized Service Facility. | p.19 |
| Engine runs good but bogs down when loads are connected. | p.19 | ||
| Engine will not crank. | 1. 10 amp fuse at rear of generator control panel has melted open. 2. Battery weak or dead. | 1. Replace fuse with only an identical 10-amp replacement fuse. 2. Recharge or replace battery. | p.19 |
| Engine will not crank. | p.19 | ||
| Engine will not start; or starts and runs rough. | 1. Dirty air cleaner. 2. Out of gasoline. 3. Stale gasoline. 4. Spark plug wire not connected to spark plug. 5. Bad spark plug. 6. Water in gasoline. 7. Overchoking. 8. Low oil level. 9. Excessive rich fuel mixture. 10. Intake valve stuck open or closed. 11. Engine has lost compression. | 1. Clean or replace air cleaner. 2. Fill fuel tank. 3. Drain fuel tank and fill with fresh fuel. 4. Connect wire to spark plug. 5. Replace spark plug. 6. Drain fuel tank; fill with fresh fuel. 7. Put choke knob to No Choke position. 8. Fill crankcase to proper level. 9. Contact Authorized Service Facility. 10. Contact Authorized Service Facility. 11. Contact Authorized Service Facility. | p.19 |
| Engine will not start; or starts and runs rough. | p.19 | ||
| Engine shuts down during operation. | 1. Out of gasoline. 2. Low oil level. 3. Fault in engine. | 1. Fill fuel tank. 2. Fill crankcase to proper level. 3. Contact Authorized Service Facility. | p.19 |
| Engine shuts down during operation. | p.19 | ||
| Engine lacks power. | 1. Load is too high. 2. Dirty air filter. 3. Engine needs to be serviced. | 1. See “Don’t Overload the Generator”. 2. Replace air filter. 3. Contact Authorized Service Facility. | p.19 |
| Engine lacks power. | p.19 | ||
| Engine “hunts” or falters. | 1. Choke is opened too soon. 2. Carburetor is running too rich or too lean. | 1. Move choke to halfway position until engine runs smoothly. 2. Contact Authorized Service Facility. | p.19 |
| Engine “hunts” or falters. | p.19 | ||
| No Battery Charge DC output. | 1. Battery posts are corroded. 2. Battery cable is bad. 3. Battery is defective. 4. Receptacle is bad. | 1. Clean battery posts. 2. Replace cable. 3. Check battery condition; replace if defective. 4. Contact Authorized Service Facility. | p.19 |