EN
Generac logo
Official user manual

Generac 005520-1

4 pages·698 KB·Portable Generator·PDF·ENDEFRITNLJA
Generac 005520-1
Table of Contents 7 sections STANDBY GENERATORS · 8 kW - 10 kW - 14 kW · Air-Cooled Gas Engine Generator Sets · Includes: · … ShowHide
Page 1 of the Generac 005520-1 user manual — FEATURES
Page 1 · click to enlarge
Page 1

STANDBY GENERATORS

Generac 005520-1 — STANDBY GENERATORS diagram (page 1)
Fig. 1

8 kW - 10 kW - 14 kW

Generac 005520-1 — 8 kW - 10 kW - 14 kW diagram (page 1)
Fig. 2 · 8 kW - 10 kW - 14 kW

Air-Cooled Gas Engine Generator Sets

Includes:

Continuous Standby Power Rating Model 005518-1 (Steel - Bisque) - 8 kW 60Hz Model 005520-1 (Steel - Bisque) - 10 kW 60Hz Model 005522-1 (Steel - Bisque) - 14 kW 60Hz

  • True Power ® Electrical Technology
  • Two Line LCD Digital Controller (10 kW & 14 kW)
  • Electronic Governor (10 kW & 14 kW)
Generac 005520-1 — Includes: diagram (page 1)
Fig. 3 · Includes:
  • External Main Circuit Breaker & System Status LED (10 kW & 14 kW)
  • Flexible Fuel Line Connector
  • Composite Mounting Pad
  • Natural Gas or LP Gas Operation
  • UL 2200 Listed

FEATURES

¡ INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance.

¡ SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine.

¡ SINGLE SOURCE SERVICE RESPONSE from Generac’s dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.

¡ TRUE POWER® ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC.

¡ GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.

¡ TEST CRITERIAPROTOTYPE TESTED NEMA MG1-22 EVALUATION SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY

®

Page 2 of the Generac 005520-1 user manual — FEATURES Standby Generator - 8 kW - 10 kW - 14 kW
Page 2 · click to enlarge
Page 2

FEATURES Standby Generator - 8 kW - 10 kW - 14 kW

ENGINE•Generac (OHVI) Design •”Spiny-lok” cast iron cylinder walls •Electronic ignition/spark advance •Full pressure lubrication system •Low oil pressure shutdown system •High temperature shutdownMaximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help engine run cooler, reducing oil consumption. Because heat is the primary cause of engine wear, the OHVI has a significantly longer life than competitive engines. Rigid construction and added durability provide long engine life. These features combine to assure smooth, quick starting every time. Superior lubrication to all vital bearings means better performance, less maintenance and significantly longer engine life. Now featuring a 2 year/200 hour oil change interval. Superior shutdown protection prevents catastrophic engine damage due to low oil. Prevents damage due to overheating. GENERATOR•Revolving field •Skewed rotor (8 & 10 kW) Skewed stator (14 kW) •Displaced phase excitation •Automatic voltage regulation •UL 2200 ListedAllows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. Produces a smooth output waveform for compatibility with electronic equipment. Maximizes motor starting capability. Regulates the output voltage to ±2% prevents damaging voltage spikes. For your safety TRANSFER SWITCHSold separately CONTROLS•Manual/Auto/Off switch •Utility voltage sensing •Utility interrupt delay •Engine warm-up •Engine cool-down •Seven day exerciser •Timed Trickle Battery charger •Main Line Circuit Breaker •Electronic governor (10 & 14 kW)Selects the operating mode. Constantly monitors utility voltage, setpoints 65% dropout, 75% pick-up, of standard voltage. Prevents nuisance start-ups of the engine, setpoint approximately 10 seconds. Ensures engine is ready to assume the load, setpoint approximately 10 seconds. Allows engine to cool prior to shutdown, setpoint approximately 1 minute. Operates engine to prevent oil seal drying and damage between power outages. Maintains battery charge level to insure starting. Protects generator from overload. Maintains constant 60 Hz frequency. UNIT•Weather protective enclosure •Enclosed critical grade muffler •Small, compact, attractiveEnsures protection against mother nature. Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Makes for an easy, eye appealing installation. INSTALLATION SYSTEM•1’ Flexible Fuel Line Connector •Composite Mounting PadEasy Installation
Page 3 of the Generac 005520-1 user manual — FEATURES Standby Generator - 8 kW - 10 kW - 14 kW
Page 3 · click to enlarge
Page 3
GENERATORModel 05518 (8 kW)Model 05520 (10 kW)Model 05522 (14 kW) Rated Maximum Continuous Power Capacity (LP)8,000 Watts*10,000 Watts*14,000 Watts* Rated Maximum Continuous Power Capacity (NG) 7,000 Watts* 9,000 Watts* 13,000 Watts* Rated Voltage120/240120/240120/240 Rated Maximum Continuous Load Current 240 Volts 33.3 LP/29.2 NG 41.6 LP/37.5 NG 58.3 LP/54.2 NG Total Harmonic DistortionLess than 5%Less than 5%Less than 5% Main Line Circuit Breaker 35 Amp 45 Amp 60 Amp Phase111 Number of Rotor Poles 2 2 2 Rated AC Frequency60Hz60Hz60Hz Power Factor 1 1 1 Battery Requirement (not included)Group 26R 12 Volts and 350 Cold-cranking Amperes MinimumGroup 26R 12 Volts and 525 Cold-cranking Amperes MinimumGroup 26R 12 Volts and 525 Cold-cranking Amperes Minimum Unit Weight 340 Pounds 387 Pounds 439 Pounds Dimensions (L” x W” x H”)48 x 25 x 2948 x 25 x 2948 x 25 x 29 Sound output in dB(A) at 23 ft. with generator operating at normal load 62 63 66 ENGINEModel 05518 (8 kW)Model 05520 (10 kW)Model 05522 (14 kW) Type of EngineGENERAC OHVIGENERAC OHVI V-TWINGENERAC OHVI V-TWIN Number of Cylinders 1 2 2 Rated Horsepower14.8 @ 3,600 rpm18 @ 3,600 rpm32 @ 3,600 rpm Displacement 410cc 530cc 992cc Cylinder BlockAluminum w/Cast Iron SleeveAluminum w/Cast Iron SleeveAluminum w/Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition SystemSolid-state w/MagnetoSolid-state w/MagnetoSolid-state w/Magneto Governor System Mechanical Electronic Electronic Compression Ratio9.4:19.5:19.5:1 Starter 12 Vdc 12 Vdc 12 Vdc Oil Capacity Including FilterApprox. 1.5 Qts.Approx. 1.7 Qts.Approx. 1.9 Qts. Operating RPM 3,600 3,600 3,600 Fuel Consumption Natural Gas cu.ft./hr. 1/2 Load Full Load Liquid Propane ft3/hr (gal/hr) 1/2 Load Full Load77 139 34 (0.94) 62 (1.68)102 156 46 (1.25) 70 (1.93)156 220 58 (1.56) 84 (2.30) Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 10 to 12 inches of water column for LP gas CONTROLS 2-Line Plain Text LCD Display (10 & 14 kW)Simple user interface for ease of operation Mode Switch -Auto Automatic Start on Utility failure. 7 day exerciser -OffStops unit. Power is removed. Control and charger still operate. -Manual/Test (start) Start with starter control, unit stays on. If utility fails, transfer to load takes place. Engine Start SequenceCyclic cranking: 16 sec. on, 7 rest (90 sec. maximum duration) Engine Warm-up 10 seconds Engine Cool-Down1 minute Starter Lock-out Starter cannot re-engage until 5 sec. after engine has stopped. 2.5 Amp Timed Trickle Battery ChargerStandard Automatic Voltage Regulator w/Overvoltage Protection Standard Automatic Low Oil Pressure ShutdownStandard Overspeed Shutdown Standard, 72Hz High Temperature ShutdownStandard Overcrank Protection Standard Safety FuseStandard

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F).

®

Page 4 of the Generac 005520-1 user manual — Standby Generator - 8 kW - 10 kW - 14 kW
Page 4 · click to enlarge
Page 4

Standby Generator - 8 kW - 10 kW - 14 kW

Generac 005520-1 — Standby Generator - 8 kW - 10 kW - 14 kW diagram (page 4)
Fig. 4 · Standby Generator - 8 kW - 10 kW - 14 kW

Design and specifications subject to change without notice. Dimensions shown are approximate. Contact your Generac dealer for certified drawings. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.

  • Generac Power Systems, Inc.
  • S45 W29290 HWY. 59, Waukesha, WI 53189
  • <a href="http://generac.com" rel="nofollow noopener" target="_blank">generac.com</a>

©2009 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0181640SBY-A Printed in U.S.A. 08/27/09

®

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Generac 005520-1

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.