Page 3 of the Generac 000 & 8 user manual — Indicates a hazardous situation or action which, if not
Page 3 · click to enlarge
Page 3

INTRODUCTION Thank you for purchasing this model by Generac Power Systems, Inc. This model is a compact, high performance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads where no utility power is available or in place of utility due to a power outage.

These safety warnings cannot eliminate the hazards that they indicate. Common sense and strict compliance with the special instructions while performing the action or service are essential to preventing accidents.

READ THIS MANUAL THOROUGHLY If any portion of this manual is not understood, contact the nearest Authorized Dealer for starting, operating and servicing procedures.

Four commonly used safety symbols accompany the DANGER, WARNING and CAUTION blocks. The type of information each indicates is as follows:

This symbol points out important safety information that, if not followed, could endanger personal safety and/or property of others.

The operator is responsible for proper and safe use of the equipment. We strongly recommend that the operator read this manual and thoroughly understand all instructions before using the equipment. We also strongly recommend instructing other users to properly start and operate the unit. This prepares them if they need to operate the equipment in an emergency.

This symbol points out potential explosion hazard.

This symbol points out potential fire hazard.

The generator can operate safely, efficiently and reliably only if it is properly located, operated and maintained. Before operating or servicing the generator:

This symbol points out potential electrical shock hazard.

  • Become familiar with and strictly adhere to all local, state and
  • national codes and regulations. Study all safety warnings in this manual and on the product
  • carefully. Become familiar with this manual and the unit before use.
  • The manufacturer cannot anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and on tags and decals affixed to the unit are, therefore, not all inclusive. If using a procedure, work method or operating technique that the manufacturer does not specifically recommend, ensure that it is safe for others. Also make sure the procedure, work method or operating technique utilized does not render the generator unsafe.

GENERAL HAZARDS

  • Never operate in an enclosed area or indoors.
  • For safety reasons, the manufacturer recommends that the
  • maintenance of this equipment is carried out by an Authorized Dealer. Inspect the generator regularly, and contact the nearest Authorized Dealer for parts needing repair or replacement. Operate generator only on level surfaces and where it will not be
  • exposed to excessive moisture, dirt, dust or corrosive vapors. Keep hands, feet, clothing, etc., away from drive belts, fans,
  • and other moving parts. Never remove any fan guard or shield while the unit is operating. Certain parts of the generator get extremely hot during
  • operation. Keep clear of the generator until it has cooled to avoid severe burns. Do NOT operate generator in the rain.
  • Do not alter the construction of the generator or change controls
  • which might create an unsafe operating condition. Never start or stop the unit with electrical loads connected
  • to receptacles AND with connected devices turned ON. Start the engine and let it stabilize before connecting electrical loads. Disconnect all electrical loads before shutting down the generator. Do not insert objects through unit’s cooling slots.
  • When working on this equipment, remain alert at all times.
  • Never work on the equipment when physically or mentally fatigued. Never use the generator or any of its parts as a step. Stepping
  • on the unit can stress and break parts, and may result in dangerous operating conditions from leaking exhaust gases, fuel leakage, oil leakage, etc. On electric start models, disconnect the POSITIVE (+) Battery
  • cable from the engine starter OR the NEGATIVE (-) Battery cable from the battery terminal, whichever is easier, before transporting the generator.

THE INFORMATION CONTAINED HEREIN WAS BASED ON MACHINES IN PRODUCTION AT THE TIME OF PUBLICATION. GENERAC RESERVES THE RIGHT TO MODIFY THIS MANUAL AT ANY TIME.

SAFETY RULES Throughout this publication, and on tags and decals affixed to the generator, DANGER, WARNING, CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular operation that may be hazardous if performed incorrectly or carelessly. Observe them carefully. Their definitions are as follows:

INDICATES A HAZARDOUS SITUATION OR ACTION WHICH, IF NOT AVOIDED, WILL RESULT IN DEATH OR SERIOUS INJURY.

Indicates a hazardous situation or action which, if not

avoided, could result in death or serious injury.

Indicates a hazardous situation or action which, if not

avoided, could result in minor or moderate injury.

Page 4 of the Generac 000 & 8 user manual — ELECTRICAL HAZARDS
Page 4 · click to enlarge
Page 4

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted near the unit's installation site. Safety should be stressed to all operators and potential operators of this equipment.

EXHAUST & LOCATION HAZARDS

  • The National Electric Code (NEC) requires the frame and external
  • electrically conductive parts of the generator be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of the generator. Consult with a local electrician for grounding requirements in the area. Use a ground fault circuit interrupter in any damp or highly
  • conductive area (such as metal decking or steel work). Do not use worn, bare, frayed or otherwise damaged electrical
  • cord sets with the generator. Before performing any maintenance on the generator, disconnect
  • the engine starting battery (if equipped) to prevent accidental start up. Disconnect the cable from the battery post indicated by a NEGATIVE, NEG or (–) first. Reconnect that cable last. In case of accident caused by electric shock, immediately shut
  • down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a non-conducting implement, such as a rope or board, to free the victim from the live conductor. If the victim is unconscious, apply first aid and get immediate medical help.

Never operate in an enclosed area or indoors! NEVER use in the home, or in partly enclosed areas such as garages, even if doors and windows are open! ONLY use outdoors and far from open windows, doors, vents, and in an area that will not accumulate deadly exhaust.

Using a generator indoors CAN KILL YOU IN MINUTES.

Utiliser un générateur à l'intérieur PEUT VOUS TUER EN QUELQUES MINUTES.

Si usa un generador en interiores, MORIRÁ EN POCOS MINUTOS.

Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.

Les gaz d'échappement du générateur contiennent du monoxyde de carbone. C'est un gaz toxique invisible et inodore.

El escape del generador contiene monóxido de carbono. Es un veneno que no tiene olor ni se puede ver.

NEVER use inside a home or garage, EVEN IF doors and windows are open. Only use OUTSIDE and far away from windows, doors, and vents. NE JAMAIS utiliser à l'intérieur d'une maison ou d'un garage, MÊME SI les portes et les fenêtres sont ouvertes. Utiliser UNIQUEMENT à l'EXTÉRIEUR et loin des fenêtres, portes et ventilations. NUNCA lo use dentro de una casa o garaje, AUN si las puertas y ventanas están abiertas. Sólo úselo EN EXTERIORES y lejos de ventanas, puertas y ductos de ventilación.

  • The engine exhaust fumes contain carbon monoxide, which
  • can you cannot see or smell. This poisonous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. Adequate, unobstructed flow of cooling and ventilating air
  • is critical to correct generator operation. Do not alter the installation or permit even partial blockage of ventilation provisions, as this can seriously affect safe operation of the generator. The generator MUST be operated outdoors. This exhaust system must be properly maintained. Do nothing
  • that might render the exhaust system unsafe or in noncompliance with any local codes and/or standards. The manufacturer recommends installing a battery operated
  • carbon monoxide alarm indoors, according to the manufacturers instructions.

FIRE HAZARDS

  • Gasoline is highly FLAMMABLE and its vapors are EXPLOSIVE.
  • Do not permit smoking, open flames, sparks or heat in the vicinity while handling gasoline. Never add fuel while unit is running or hot. Allow engine to
  • cool completely before adding fuel. Never fill fuel tank indoors.
  • Comply with all laws regulating storage and handling of gasoline. Do not overfill the fuel tank. Always allow room for fuel
  • expansion. If tank is over-filled, fuel can overflow onto a hot engine and cause FIRE or an EXPLOSION. Never store generator with fuel in tank where gasoline vapors might reach an open flame, spark or pilot light (as on a furnace, water heater or clothes dryer). FIRE or EXPLOSION may result. Allow unit to cool entirely before storage. Wipe up any fuel or oil spills immediately. Ensure that no
  • combustible materials are left on or near the generator. Keep the area surrounding the generator clean and free from debris and keep a clearance of five (5) feet on all side to allow for proper ventilation of the generator. Do not insert objects through unit’s cooling slots.
  • Do not
  • operate the generator if connected electrical devices overheat, if electrical output is lost, if engine or generator sparks or if flames or smoke are observed while unit is running. Keep a fire extinguisher near the generator at all times.

ELECTRICAL HAZARDS

  • The generator produces dangerously high voltage when in
  • operation. Avoid contact with bare wires, terminals, connections, etc., while the unit is running, even on equipment connected to the generator. Ensure all appropriate covers, guards and barriers are in place before operating the generator. Never handle any kind of electrical cord or device while
  • standing in water, while barefoot or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK MAY RESULT.
Page 5 of the Generac 000 & 8 user manual — IMPORTANT SAFETY INSTRUCTIONS
Page 5 · click to enlarge
Page 5

IMPORTANT SAFETY INSTRUCTIONS

STANDARDS INDEX

CALIFORNIA PROPOSITION 65 WARNING Engine exhaust and some of its constituents are known

In the absence of pertinent standards, codes, regulations and laws, the published information listed below may be used as a guideline for operation of this equipment. Always reference the latest revision available for the standards listed.

to the State of California to cause cancer, birth defects

and other reproductive harm.

1. NFPA No. 70, NFPA HANDBOOK OF NATIONAL ELECTRIC CODE. 2. Article X, NATIONAL BUILDING CODE, available from the American Insurance Association, 85 John Street, New York, N.Y. 10038. 3. AGRICULTURAL WIRING HANDBOOK, available from the Food and Energy Council, 909 University Avenue, Columbia, MO 65201. 4. ASAE EP-3634, INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS, available from the American Society of Agricultural Engineers, 2950 Niles Road, St. Joseph, MI 49085.

CALIFORNIA PROPOSITION 65 WARNING This product contains or emits chemicals known to the

State of California to cause cancer, birth defects and

other reproductive harm.

Page 6 of the Generac 000 & 8 user manual — 1.2.2 STARTER CONNECTION (ELECTRIC START ONLY)
Page 6 · click to enlarge
Page 6

Section 1 – General Information

1.1 UNPACKING

Figure 1 – Wheel Assembly

  • Remove all packaging material.
  • Remove separate accessory box.
  • Remove the generator from carton.
Generac 000 & 8 — Section 1 – General Information diagram (page 6)
Fig. 2 · Section 1 – General Information

1.1.1 ACCESSORY BOX

Check all contents. If any parts are missing or damaged locate an authorized dealer at 1-888-436-3722.

Contents Include:

  • 1 – Owner’s Manual
  • 1 - Left Handle Assembly
  • 1 - Quart Oil SAE 30
  • 1 - Right Handle Assembly
  • 2 - Never-Flat Wheels
  • 1 - Frame Foot
  • 1 - 12 volt Adapter Plug
  • 1 - Foot Support
  • Charger* 1 - Hardware Bag (containing the following):
  • 2 - Rubber Feet 2 - 5/16” Bolts 2 - 5/16” Flat Washers 4 - 5/16” Locking Flange Nuts 4 - 5/16” Carriage Bolts 2 - 5/16” Locking Cap Nuts 2 - 1/2” Axle Bolts 2 - 1/2” Locking Flange Nuts 2 - 1/2" Flat Washers * Electric start units only.

Figure 2 – Install Handle Kit

Generac 000 & 8 — Figure 2 – Install Handle Kit diagram (page 6)
Fig. 3 · Figure 2 – Install Handle Kit

1.2 ASSEMBLY The generator requires some assembly prior to using it. If problems arise when assembling the generator, please call the Generator Helpline at 1-888-436-3722.

1.2.1 ASSEMBLING THE ACCESSORY KIT

The wheels are designed into the unit to greatly improve the portability of the generator.

The wheels are not intended for over-the-road use.

1.2.2 STARTER CONNECTION (ELECTRIC START ONLY)

  • 1. Refer to Figure 1 and install Wheels as follows:
  • Slide the 1/2” Axle Bolt through the 1/2" Washer, the Wheel and Wheel bracket on frame.
  • Install 1/2” Locking Flange Nuts onto 1/2” Flange Bolt. 2. Refer to Figure 1 and install Frame Foot, Foot Support and Rubber Feet as shown.
  • Slide Rubber Foot stud through the Foot Support and Frame Foot; Install 5/16” Locking Flange Nuts Slide 5/16” Bolt through 5/16” Flat Washer and then through holes in Frame Rail.
  • Slide Frame Foot onto 5/16” Bolts; Install 5/16” Locking Flange Nuts. 3. Refer to Figure 2 and install Handles as shown.
  • Remove top Curved Head Bolts and Cap Nuts (Cap Nuts will be re-used).
  • Slide Handle Assembly over Frame Tube, aligning 2 holes.
  • Slide 5/16” Carriage Bolts through; Install 5/16” Cap Nuts.

The unit has been deliberately shipped with the starter cable disconnected.

To connect starter:

1. Locate starter cable (a hang tag is attached as shown in Figure 3). 2. Pull vinyl boot back onto starter cable. 3. Remove nut and washer from starter post. 4. Put starter cable onto post and re-install washer and nut.
Page 7 of the Generac 000 & 8 user manual — Figure 6 - Generator Controls
Page 7 · click to enlarge
Page 7

Figure 3 – Starter Connection

11. Handles – Pivot and retract for storage. Press the spring- loaded button to move handles. 12. Gas Cap – Fuel fill location. 13. Fuel Gauge – Shows fuel level in tank. 14. Oil Fill – Add oil here. 15. Recoil Starter – Use to start engine manually. 16. Fuel Shut Off – Valve between fuel tank and carburetor. 17. Oil Drain – Use to drain engine oil. 18*. Battery Charger Input – This receptacle allows the capability to recharge the 12 volt DC storage battery provided with the 12 Volt Adaptor Plug Charger which is included in the Accessory Box. Located behind the battery charger input is a 1.50 Amp in-line fuse which is inside the control panel to protect the battery. 19*. Battery – Powers the electric starter. * Electric start only.

Generac 000 & 8 — Figure 3 – Starter Connection diagram (page 7)
Fig. 4 · Figure 3 – Starter Connection

2.1 KNOW THE GENERATOR Read the Owner’s Manual and Safety Rules before operating this generator.

Figure 5 - Generator Controls

Generac 000 & 8 — Figure 5 - Generator Controls diagram (page 7)
Fig. 5 · Figure 5 - Generator Controls

Compare the generator to Figures 4 through 6 to become familiarized with the locations of various controls and adjustments. Save this manual for future reference.

1. 120 Volt AC, 20 Amp, Duplex Receptacle – Supplies electrical power for the operation of 120 Volt AC, 20 Amp, single-phase, 60 Hz electrical lighting, appliance, tool and motor loads. 2. 120/240 Volt AC, 30 Amp Locking Receptacle – Supplies electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single-phase, 60 Hz, electrical lighting, appliance, tool and motor loads. 3. Circuit Breakers (AC) – Each receptacle is provided with a push-to-reset circuit breaker to protect the generator against electrical overload.

Figure 4 - Control Panel

Generac 000 & 8 — Figure 4 - Control Panel diagram (page 7)
Fig. 6 · Figure 4 - Control Panel

Figure 6 - Generator Controls

Generac 000 & 8 — Figure 6 - Generator Controls diagram (page 7)
Fig. 7 · Figure 6 - Generator Controls
4. Hourmeter – Tracks hours of operation. 5. Air Filter – Filters intake air as it is drawn into the engine. 6. Choke Knob – Used when starting a cold engine. 7. Fuel Tank – Tank holds 6.6 U.S. gallons of fuel. 8. Grounding Lug – Ground the generator to an approved earth ground here. See "Grounding the Generator" for details. 9. Run/Stop Switch – Controls the operation of the generator. 10. Muffler – Quiets the engine.
Page 8 of the Generac 000 & 8 user manual — 2.4.1 GROUNDING THE GENERATOR
Page 8 · click to enlarge
Page 8

2.2 HOURMETER The Hourmeter tracks hours of operation for scheduled maintenance:

2.3.2 120/240 VAC, 30 AMP RECEPTACLE

Use a NEMA L14-30 plug with this receptacle (rotate to lock/ unlock). Connect a suitable 4-wire grounded cord set to the plug and to the desired load. The cord set should be rated for 250 Volts AC at 30 Amps (or greater) (Figure 8).

There will be a "CHG OIL" message every 100 hours. The message will flash one hour before and one hour after each 100 hour interval, again providing a two hour window to perform service.

Figure 8 - 120/240 VAC, 30 Amp Receptacle

This message will actually begin flashing at 99 hours and disable itself at 101 hours providing a two hour window to perform the service.

Every 200 hours the "SVC" icon on the lower left hand corner of the display will flash. The message will flash one hour before and one hour after each 200 hour interval providing a two hour window to perform service.

When the hour meter is in the Flash Alert mode, the maintenance message will always alternate with elapsed time in hours and tenths. The hours will flash four times, then alternate with the maintenance message four times until the meter resets itself.

  • 100 hours - CHG OIL — Oil Change Interval (Every 100 hrs)
  • 200 hours - SVC — Air Filter Interval (Every 200 hrs)

Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps or 240 Volt AC, 60 Hz, single phase loads requiring up to 7200 watts (7.2 kW) of power at 30 Amps. The outlet is protected by two 30 Amp push-to-reset circuit breakers.

2.3 CORD SETS AND CONNECTION PLUGS

2.3.1 120 VAC, 20 AMP, DUPLEX RECEPTACLE

This is a 120 Volt outlet protected against overload by a 20 Amp push-to-reset circuit breaker (Figure 7). Use each socket to power 120 Volt AC, single phase, 60 Hz electrical loads requiring up to a combined 2400 watts (2.4 kW) or 20 Amps of current. Use only high quality, well-insulated, 3-wire grounded cord sets rated for 125 Volts at 20 Amps (or greater).

2.4 HOW TO USE THE GENERATOR If there are any problems operating the generator, please call the generator helpline at 1-888-436-3722.

Keep extension cords as short as possible, preferably less than 15 feet long, to prevent voltage drop and possible overheating of wires.

Using a generator indoors CAN KILL YOU IN MINUTES.

Utiliser un générateur à l'intérieur PEUT VOUS TUER EN QUELQUES MINUTES.

Si usa un generador en interiores, MORIRÁ EN POCOS MINUTOS.

Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.

Les gaz d'échappement du générateur contiennent du monoxyde de carbone. C'est un gaz toxique invisible et inodore.

El escape del generador contiene monóxido de carbono. Es un veneno que no tiene olor ni se puede ver.

Figure 7 - 120 Volt AC, 20 Amp, Duplex Receptacle

NEVER use inside a home or garage, EVEN IF doors and windows are open. Only use OUTSIDE and far away from windows, doors, and vents. NE JAMAIS utiliser à l'intérieur d'une maison ou d'un garage, MÊME SI les portes et les fenêtres sont ouvertes. Utiliser UNIQUEMENT à l'EXTÉRIEUR et loin des fenêtres, portes et ventilations. NUNCA lo use dentro de una casa o garaje, AUN si las puertas y ventanas están abiertas. Sólo úselo EN EXTERIORES y lejos de ventanas, puertas y ductos de ventilación.

2.4.1 GROUNDING THE GENERATOR

The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground (Figure 9). Local electrical codes may also require proper grounding of the unit. For that purpose, connecting a No. 10 AWG (American Wire Gauge) stranded copper wire to the grounding lug and to an earth-driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. However, local codes may vary widely. Consult with a local electrician for grounding requirements in the area.

Page 9 of the Generac 000 & 8 user manual — 2.4.2 CONNECTING ELECTRICAL LOADS
Page 9 · click to enlarge
Page 9

Figure 9 - Grounding the Generator

1. Figure the watts needed to start the largest motor. 2. Add to that figure the running watts of all other connected loads. The Wattage Reference Guide is provided to assist in determining how many items the generator can operate at one time.
Generac 000 & 8 — Figure 9 - Grounding the Generator diagram (page 9)
Fig. 8 · Figure 9 - Grounding the Generator

2.6 WATTAGE REFERENCE GUIDE

Device Running Watts *Air Conditioner (12,000 Btu) 1700 *Air Conditioner (24,000 Btu) 3800 *Air Conditioner (40,000 Btu) 6000 Battery Charger (20 Amp) 500 Belt Sander (3") 1000 Chain Saw 1200 Circular Saw (6-1/2") 800 to 1000 *Clothes Dryer (Electric) 5750 *Clothes Dryer (Gas) 700 *Clothes Washer 1150 Coffee Maker 1750 *Compressor (1 HP) 2000 *Compressor (3/4 HP) 1800 *Compressor (1/2 HP) 1400 Curling Iron 700 *Dehumidifier 650 Disc Sander (9") 1200 Edge Trimmer 500 Electric Blanket 400 Electric Nail Gun 1200 Electric Range (per element) 1500 Electric Skillet 1250 *Freezer 700 *Furnace Fan (3/5 HP) 875 *Garage Door Opener 500 to 750 Hair Dryer 1200 Hand Drill 250 to 1100 Hedge Trimmer 450 Impact Wrench 500 Iron 1200 *Jet Pump 800 Lawn Mower 1200 Light Bulb 100 Microwave Oven 700 to 1000 *Milk Cooler 1100 Oil Burner on Furnace 300 Oil Fired Space Heater (140,000 Btu) 400 Oil Fired Space Heater (85,000 Btu) 225 Oil Fired Space Heater (30,000 Btu) 150 *Paint Sprayer, Airless (1/3 HP) 600 Paint Sprayer, Airless (handheld) 150 Radio 50 to 200 *Refrigerator 700 Slow Cooker 200

Proper grounding of the generator will help prevent electrical shock in the event of a ground fault condition in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices.

2.4.2 CONNECTING ELECTRICAL LOADS

DO NOT connect 240 Volt loads to 120 Volt receptacles. DO NOT connect 3-phase loads to the generator. DO NOT connect 50 Hz loads to the generator.

  • Let engine stabilize and warm up for a few minutes after
  • starting. Plug in and turn on the desired 120 or 240 Volt AC, single
  • phase, 60 Hz electrical loads. Add up the rated watts (or amps) of all loads to be connected
  • at one time. This total should not be greater than (a) the rated wattage/amperage capacity of the generator or (b) circuit breaker rating of the receptacle supplying the power. See "Don't Overload the Generator".

2.5 DON’T OVERLOAD THE GENERATOR Overloading a generator in excess of its rated wattage capacity can result in damage to the generator and to connected electrical devices. Observe the following to prevent overloading the unit:

  • Add up the total wattage of all electrical devices to be connected
  • at one time. This total should NOT be greater than the generator's wattage capacity. The rated wattage of lights can be taken from light bulbs. The
  • rated wattage of tools, appliances and motors can usually be found on a data label or decal affixed to the device. If the appliance, tool or motor does not give wattage, multiply
  • volts times ampere rating to determine watts (volts x amps = watts). Some electric motors, such as induction types, require about
  • three times more watts of power for starting than for running. This surge of power lasts only a few seconds when starting such motors. Make sure to allow for high starting wattage when selecting electrical devices to connect to the generator:
Page 10 of the Generac 000 & 8 user manual — DO NOT Fill Above Lip Fuel
Page 10 · click to enlarge
Page 10

*Submersible Pump (1-1/2 HP) 2800 *Submersible Pump (1 HP) 2000 *Submersible Pump (1/2 HP) 1500 *Sump Pump 800 to 1050 *Table Saw (10") 1750 to 2000 Television 200 to 500 Toaster 1000 to 1650 Weed Trimmer 500 * Allow 3 times the listed watts for starting these devices.

Figure 10 – Oil Level

Generac 000 & 8 — Figure 10 – Oil Level diagram (page 10)
Fig. 9 · Figure 10 – Oil Level

2.7 BEFORE STARTING THE GENERATOR Prior to operating the generator, engine oil and gasoline will need to be added, as follows:

2.7.1 ADDING ENGINE OIL

All oil should meet minimum American Petroleum Institute (API) Service Class SJ, SL or better. Use no special additives. Select the oil's viscosity grade according to the expected operating temperature (also see chart).

2.7.2 ADDING GASOLINE

DANGER

  • Above 40° F, use SAE 30
  • Below 40° F and down to 10° F, use 10W-30
  • Below 10° F, use synthetic 5W-30

Never fill fuel tank indoors. Avoid spilling

gasoline on hot engine. Allow engine to cool entirely before adding fuel. Never fill fuel tank when engine is running or hot. DO NOT light a cigarette or smoke when filling the fuel tank. Gasoline is highly flammable and its vapors are explosive. Do not overfill the fuel tank. Always leave room

Generac 000 & 8 — Never fill fuel tank indoors. Avoid spilling diagram (page 10)
Fig. 10 · Never fill fuel tank indoors. Avoid spilling
  • for fuel expansion. If the fuel tank is overfilled, fuel can over flow onto a hot engine and cause fire or an explosion. Wipe up any spilled fuel immediately. Use regular UNLEADED gasoline with the generator engine. Do
  • not use premium gasoline. Do not mix oil with gasoline. Clean area around fuel fill cap, remove cap.
  • Slowly add unleaded regular gasoline to fuel tank. Fill to bottom
  • of screen filter. Be careful not to overfill (Figure 11). Install fuel cap and wipe up any spilled gasoline.

Any attempt to crank or start the engine before

  • it has been properly serviced with the recommended oil may result in an engine failure. Place generator on a level surface.
  • Clean area around oil fill and remove oil fill cap.
  • Slowly fill engine with oil until it reaches the threads of the oil
  • fill opening (see Figure 10). Stop filling occasionally to check oil level. Install oil fill cap and finger tighten securely.
  • Check engine oil level before starting each time thereafter.

Figure 11 - Fuel Tank

Fuel Tank

Generac 000 & 8 — Figure 11 - Fuel Tank diagram (page 10)
Fig. 11 · Figure 11 - Fuel Tank

DO NOT Fill Above Lip Fuel

Page 11 of the Generac 000 & 8 user manual — Figure 14 - Fuel Shut-off Valve
Page 11 · click to enlarge
Page 11

IMPORTANT: It is important to prevent gum deposits from forming in fuel system parts such as the carburetor, fuel hose or tank during storage. Alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage. To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. See the "Storage" section. Never use engine or carburetor cleaner products in the fuel tank as permanent damage may occur.

Figure 13 - Choke Position

Choke

Generac 000 & 8 — Figure 13 - Choke Position diagram (page 11)
Fig. 12 · Figure 13 - Choke Position

2.8 STARTING PULL START ENGINES

Never start or stop engine with electrical

  • devices plugged into the receptacles AND devices turned on. Unplug all electrical loads from the unit's receptacles before
  • starting the engine. Make sure the unit is in a level position.
  • OPEN
  • the Fuel Shut-off Valve (Figures 12 and 14). Turn engine RUN/STOP switch to
  • ON position (Figure 15). Pull engine CHOKE knob outward to
  • FULL CHOKE position (Figure 13). To start engine, firmly grasp the recoil handle and pull slowly
  • until increased resistance is felt. Pull rapidly up and away. When engine starts, move choke knob to
  • 1/2-CHOKE position until engine runs smoothly and then fully into RUN position. If engine falters, move choke back out to 1/2-CHOKE position until engine runs smoothly and then to RUN position.

Never start or stop engine with electrical

  • devices plugged into the receptacles AND devices turned on. Unplug all electrical loads from the unit's receptacles before
  • starting the engine. Make sure the unit is in a level position.
  • Open the fuel shut-off valve (Figures 12 and 14).
  • Move engine CHOKE knob outward to
  • “Full Choke” position (Figure 15).

Figure 12 - Fuel Shut-off Valve

Generac 000 & 8 — Figure 12 - Fuel Shut-off Valve diagram (page 11)
Fig. 13 · Figure 12 - Fuel Shut-off Valve

Figure 14 - Fuel Shut-off Valve

Generac 000 & 8 — Figure 14 - Fuel Shut-off Valve diagram (page 11)
Fig. 14 · Figure 14 - Fuel Shut-off Valve
  • To start engine, press and hold the Start/Run/Stop switch in
  • the “Start” position. The engine will crank and attempt to start. When the engine starts, release the switch to the run position. When the engine starts, move choke knob to “1/2 Choke”
  • position until the engine runs smoothly and then fully in to the “Run” position. If engine falters, move choke knob back out to “1/2 Choke” position until the engine runs smoothly and then to “Run” position.

If engine fires, but does not continue to run, move choke lever to FULL CHOKE and repeat starting instructions.

Page 12 of the Generac 000 & 8 user manual — BATTERY
Page 12 · click to enlarge
Page 12

This generator is also equipped with a manual recoil starter • which may be used if the battery is discharged.

2.11.1 SENSING LOW OIL LEVEL

If the system senses a low oil level during operation, the engine shuts down. The engine will not run until the oil has been refilled to the proper level.

The switch must be in the RUN position.

To start manually, firmly grasp the recoil handle and pull slowly • until increased resistance is felt. Pull rapidly up and away to start engine. Then follow the same choke sequence.

2.12 CHARGING THE BATTERY (ELECTRIC START UNITS ONLY)

DANGER

If engine fires, but does not continue to run, move choke lever to “Full Choke” and repeat starting instructions.

Storage batteries give off explosive hydrogen

gas while recharging. An explosive mixture will remain around the battery for a long time after it has been charged. The slightest spark can ignite the hydrogen and cause an explosion. Such an explosion can shatter the battery and cause blindness or other serious injury.

Figure 15 - Choke Position

Choke

Generac 000 & 8 — Figure 15 - Choke Position diagram (page 12)
Fig. 15 · Figure 15 - Choke Position

DANGER

Do not permit smoking, open flame, sparks or

any other source of heat around a battery. Wear protective goggles, rubber apron and rubber gloves when working around a battery. Battery electrolyte fluid is an extremely corrosive sulfuric acid solution that can cause severe burns. If spill occurs flush area with clear water immediately.

The battery shipped with the generator has been fully charged. A battery may lose some of its charge when not in use for prolonged periods of time. If the battery is unable to crank the engine, plug in the 12V charger included in the accessory box (see section "Charging the Battery"). RUNNING THE GENERATOR DOES NOT CHARGE THE BATTERY.

Use battery charger plug to keep the battery charged and ready for use. Battery charging should be done in a dry location.

2.10 STOPPING THE ENGINE

  • Shut off all loads, then unplug the electrical loads from generator
  • panel receptacles. Never start or stop the engine with electrical devices plugged in and turned on. Let engine run at no-load for several minutes to stabilize the
  • internal temperatures of engine and generator. Move Run/Stop switch to
  • OFF position. Close fuel valve.
1. Plug charger into “Battery Charger Input” jack, located on the control panel. Plug wall receptacle end of the battery charger into a 120 Volt AC wall outlet (Figure 16). 2. Unplug battery charger from wall outlet and control panel jack when generator is going to be in use.

Figure 16 - Battery Charger Jack

2.11 LOW OIL LEVEL SHUTDOWN SYSTEM The engine is equipped with a low oil level sensor that shuts down the engine automatically when the oil level drops below a specified level. If the engine shuts down by itself and the fuel tank has enough gasoline, check engine oil level.

BATTERY

CHARGER

INPUT

Page 13 of the Generac 000 & 8 user manual — 3.3.2 TO CLEAN THE GENERATOR
Page 13 · click to enlarge
Page 13

Section 3 — Maintenance

3.3 GENERAL RECOMMENDATIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.

Do not use the battery charger for more than 48 hours at one charge.

3.1 MAINTENANCE SCHEDULE Follow the calendar intervals. More frequent service is required when operating in adverse conditions noted below.

Some adjustments will need to be made periodically to properly maintain the generator.

All adjustments in the Maintenance section of this manual should be made at least once each season. Follow the requirements in the "Maintenance Schedule".

Check Oil Level At Each Use Change Oil ‡ *Every 100 hours or Every Season Check Valve Clearance ***Every Season Service Air Filter ** Every 200 hours or Every Season Replace Spark Plug Every Season

‡ Change oil after first 30 hours of operation then every season. * Change oil and oil filter every month when operating under heavy load or in high temperatures. ** Clean more often under dirty or dusty operating conditions. Replace air filter parts if they cannot be adequately cleaned. *** Check valve clearance and adjust if necessary after first 50 hours of operation and every 100 hours thereafter.

3.3.1 GENERATOR MAINTENANCE

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material.

3.2 PRODUCT SPECIFICATIONS

3.2.1 GENERATOR SPECIFICATIONS

Check the cleanliness of the generator frequently and clean when dust, dirt, oil, moisture or other foreign substances are visible on its exterior surface.

Rated. Power 7.0/8.0 kW** Surge Power 8.7/12.0 kW Rated AC Voltage 120/240 Rated Max AC Load Current @ 240V (7.0/8.0 kW) 25 Amps/30 Amps** Current @ 120V 20 Amps** Rated Frequency 60 Hz @ 3600 RPM Phase Single Phase

Never insert any object or tool through the air

cooling slots, even if the engine is not running.

NOTE: DO NOT use a garden hose to clean generator. Water can enter the engine fuel system and cause problems. In addition, if water enters the generator through cooling air slots, some water will be retained in voids and crevices of the rotor and stator winding insulation. Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

** Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambient temperature, altitude, engine condition, etc.. Maximum power decreases about 3.5% for each 1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F) ambient temperature.

3.2.2 ENGINE SPECIFICATIONS

Rated Horsepower @ 3600 RPM 14.5 Displacement 410cc Spark Plug Type Champion RC14YC or Equivalent Spark Plug Gap 0.030 inch or (0.76 mm) Gasoline Capacity 8 U.S. gallons Oil Type See Chart in "Adding Engine Oil" Section Oil Capacity w/ Filter Change = 1.5 Qts. w/o Filter Change = 1.2 Qts. Run Time/Fuel Consumption-1/2 Load .. 10 Hours / .80 gallons per hour Class II Emission Certified

3.3.2 TO CLEAN THE GENERATOR

  • Use a damp cloth to wipe exterior surfaces clean.
  • A soft, bristle brush may be used to loosen caked on dirt, oil,
  • etc. A vacuum cleaner may be used to pick up loose dirt and
  • debris. Low pressure air (not to exceed 25 psi) may be used to
  • blow away dirt. Inspect cooling air slots and openings on the generator. These openings must be kept clean and unobstructed.
Page 14 of the Generac 000 & 8 user manual — CABLE (RED) SCREW
Page 14 · click to enlarge
Page 14

Section 3 — Maintenance

3.3.3 ENGINE MAINTENANCE

Figure 17 - Spark Plug Gap

Generac 000 & 8 — Section 3 — Maintenance diagram (page 14)
Fig. 16 · Section 3 — Maintenance

DANGER

When working on the generator, always

disconnect negative cable from battery. Also disconnect spark plug wire from spark plug and keep wire away from spark plug.

3.3.4 CHECKING OIL LEVEL

See the “Before Starting the Generator” section for information on checking the oil level. The oil level should be checked before each use, or at least every eight hours of operation. Keep the oil level maintained.

3.3.7 BATTERY REPLACEMENT

The battery shipped with the generator has been fully charged. A battery may lose some of its charge when not in use for prolonged periods of time. If the battery is unable to crank the engine, plug in the 12V charger included in the accessory box (see the Charging a Battery section). RUNNING THE GENERATOR DOES NOT CHARGE THE BATTERY.

3.3.5 CHANGING THE OIL

Change the oil after the first 30 hours of operation. Change the oil every 100 hours or every season thereafter. If running this unit under dirty or dusty conditions, or in extremely hot weather, change the oil more often.

The NEGATIVE battery terminal should:

Hot oil may cause burns. Allow engine to cool

before draining oil. Avoid prolonged or repeated skin exposure with used oil. Thoroughly wash exposed areas with soap. Use the following instructions to change the oil while the engine is still warm:

1. Always be DISCONNECTED FIRST. 2. Always be CONNECTED LAST.

Figure 18 - Battery Connections

  • Clean area around oil drain plug.
  • Remove oil drain plug from engine and oil fill plug to drain oil
  • completely into a suitable container. When oil has completely drained, install oil drain plug and
  • tighten securely. Fill oil sump with recommended oil. (See “Before Starting the
  • Generator” for oil recommendations). Wipe up any spilled oil.
  • Dispose of used oil at a proper collection center.

(BLACK)

NUT

Generac 000 & 8 — (BLACK) diagram (page 14)
Fig. 17

LOCK WASHER

FLAT WASHER

CABLE BOOT

3.3.6 REPLACING THE SPARK PLUG

Use Champion RC14YC spark plug or equivalent. Replace the plug once each year. This will help the engine start easier and run better.

CABLE (RED) SCREW

1. Stop the engine and pull the spark plug wire off of the spark plug. 2. Clean the area around the spark plug and remove it from the cylinder head. 3. Set the spark plug's gap to 0.70-0.80 mm (0.028-0.031 in.). Install the correctly gapped spark plug into the cylinder head (Figure 17).
Page 15 of the Generac 000 & 8 user manual — Clean and inspect the spark arrestor as follows:
Page 15 · click to enlarge
Page 15

Section 3 — Maintenance

3.4 SERVICE AIR CLEANER The engine will not run properly and may be damaged if using a dirty air cleaner. Clean or replace the air cleaner paper filter once a year (Figure 19). Clean or replace more often if operating under dusty conditions.

Figure 20 - Spark Arrestor

Generac 000 & 8 — Figure 20 - Spark Arrestor diagram (page 15)
Fig. 18 · Figure 20 - Spark Arrestor

Figure 19 - Air Cleaner

Generac 000 & 8 — Figure 19 - Air Cleaner diagram (page 15)
Fig. 19 · Figure 19 - Air Cleaner

3.6 ADJUSTING VALVE CLEARANCE After the first 50 hours of operation, check the valve clearance in the engine and adjust if necessary.

To clean or replace paper air filter:

  • Remove air cleaner cover and remove paper filter.
  • Clean paper filter by tapping it gently on a solid surface. If the
  • filter is too dirty, replace it with a new one. Dispose of the old filter properly. Clean air cleaner cover, then insert new paper filter into the base
  • of the air cleaner. Re-install air cleaner cover.

To check valve clearance:

  • Make sure the engine is at room temperature (60° - 80° F).
  • Make sure that the spark plug wire is removed from the spark
  • plug and out of the way. Remove spark plug. Remove the four screws attaching the valve cover.
  • Make sure the piston is at Top Dead Center (TDC) of its
  • compression stroke (both valves closed). To get the piston at TDC, remove the intake screen at the front of the engine to gain access to the flywheel nut. Use a large socket and socket wrench to rotate the nut and hence the engine in a clockwise direction while watching the piston through the spark plug hole. The piston should move up and down. The piston is at TDC when it is up as high as it can go. Insert a 0.002 - 0.004 inch (0.05 - 0.1mm) feeler gauge
  • between the rocker arm and valve stem. Correct clearance is when a slight drag is felt when sliding the gauge back and forth. If the clearance is either excessively loose or tight the rocker arms will need adjusting. To adjust valve clearance:

To order a new air filter, please contact the nearest authorized service center at 1-800-333-1322.

3.5 CLEAN SPARK ARRESTOR SCREEN The engine exhaust muffler has a spark arrestor screen. Inspect and clean the screen at least once each year (Figure 20). If unit is used regularly, inspect and clean more often.

If using the generator on any forest-covered, brush-covered or grass-covered unimproved land, it must equipped with a spark arrestor. The spark arrestor must be maintained in good condition by the owner/operator.

Clean and inspect the spark arrestor as follows:

  • Remove muffler heat shield from muffler, removing four
  • screws. Remove spark arrestor from muffler, removing four screws.
  • Inspect screen and replace if torn, perforated or otherwise
  • damaged. DO NOT USE a defective screen. If screen is not damaged, clean it with commercial solvent. Replace the spark arrestor and muffler heat shield.

Loosen the rocker jam nut (Figure 21). Use an 10mm allen • wrench to turn the pivot ball stud while checking clearance between the rocker arm and the valve stem with a feeler gauge. Correct clearance is 0.002-0.004 inch (0.05-0.1 mm).

Page 16 of the Generac 000 & 8 user manual — NEVER cover the generator while engine and
Page 16 · click to enlarge
Page 16

Section 3 — Maintenance

Figure 21 - Valve Clearance Adjustment

DANGER

Generac 000 & 8 — Section 3 — Maintenance diagram (page 16)
Fig. 20 · Section 3 — Maintenance

Drain fuel into approved container outdoors,

  • away from open flame. Be sure engine is cool. Do not smoke. Start and run engine until engine stops from lack of fuel.
  • Allow the engine to cool, then drain oil from crankcase. Refill
  • with recommended grade. Remove spark plug and pour about 1/2 ounce (15 ml) of engine
  • oil into the cylinder. Cover spark plug hole with rag. Pull the recoil starter a couple times to lubricate the piston rings and cylinder bore.

Avoid spray from spark plug hole when cranking

  • engine. Install and tighten spark plug. Do not connect spark plug wire.
  • Clean the generator's outer surfaces. Check that cooling air
  • slots and openings on generator are open and unobstructed. Store the unit in a clean, dry place.

The rocker arm jam nut must be held in place as the pivot ball stud is turned.

When valve clearance is correct, hold the pivot ball stud in place with the allen wrench and tighten the rocker arm jam nut. Tighten the jam nut to 174 in/lbs. torque. After tightening the jam nut, recheck valve clearance to make sure it did not change.

3.8 OTHER STORAGE TIPS

  • Do not store gasoline from one season to another.
  • Replace the gasoline can if it starts to rust. Rust and/or dirt in
  • the gasoline will cause problems with the carburetor and fuel system. If possible, store the unit indoors and cover it to give protection
  • from dust and dirt. BE SURE TO EMPTY THE FUEL TANK. If it is not practical to empty the fuel tank and the unit is to be
  • stored for some time, use a commercially available fuel stabilizer added to the gasoline to increase the life of the gasoline. Cover the unit with a suitable protective cover that does not
  • retain moisture.
  • Install new valve cover gasket.
  • Re-attach the valve cover.

Start all four screws before tightening or it will not be possible to get all the screws in place. Make sure the valve cover gasket is in place. Replace spark plug.

Re-attach the spark plug wire to the spark plug. •

3.7 LONG TERM STORAGE It is important to prevent gum deposits from forming in essential fuel system parts such as the carburetor, fuel hose or tank during storage. Also, experience indicates that alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage.

DANGER

NEVER cover the generator while engine and

exhaust area are warm.

To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer, as follows:

Remove all gasoline from the fuel tank. •

Page 17 of the Generac 000 & 8 user manual — Section 4 — Troubleshooting
Page 17 · click to enlarge
Page 17

Section 4 — Troubleshooting

4.1 TROUBLESHOOTING GUIDE

PROBLEM CAUSE CORRECTION

Engine is running, but no AC output is available.

1. Circuit breaker is open. 2. Poor connection or defective cord set. 3. Connected device is bad. 4. Fault in generator.
1. Reset circuit breaker. 2. Check and repair. 3. Connect another device that is in good condition. 4. Contact Authorized Service Facility.

Engine runs good but bogs down when loads are connected.

1. Short circuit in a connected load. 2. Generator is overloaded. 3. Engine speed is too slow. 4. Shorted generator circuit.
1. Disconnect shorted electrical load. 2. See “Don’t Overload the Generator” . 3. Contact Authorized Service Facility. 4. Contact Authorized Service Facility.

Engine will not start; or starts and runs rough.

1. Fuel Shut-off is OFF. 2. Dirty air filter. 3. Out of gasoline. 4. Stale gasoline. 5. Spark plug wire not connected to spark plug. 6. Bad spark plug. 7. Water in gasoline. 8. Over-choking. 9. Low oil level. 10. Excessive rich fuel mixture. 11. Intake valve stuck open or closed. 12. Engine has lost compression.
1. Turn Fuel Shut-off to ON. 2. Clean or replace air filter. 3. Fill fuel tank. 4. Drain fuel tank and fill with fresh fuel. 5. Connect wire to spark plug. 6. Replace spark plug. 7. Drain fuel tank; fill with fresh fuel. 8. Put choke knob to No Choke position. 9. Fill crankcase to proper level. 10. Contact Authorized Service Facility. 11. Contact Authorized Service Facility. 12. Contact Authorized Service Facility.

Engine shuts down during operation.

1. Out of gasoline. 2. Low oil level. 3. Fault in engine.
1. Fill fuel tank. 2. Fill crankcase to proper level. 3. Contact Authorized Service Facility.

Engine lacks power. 1. Load is too high. 2. Dirty air filter. 3. Engine needs to be serviced.

1. Reduce load (see “Don’t Overload the Generator”). 2. Clean or replace air filter. 3. Contact Authorized Service Facility.

Engine “hunts” or falters. 1. Choke is opened too soon.

1. Move choke to halfway position until engine runs smoothly. 2. Contact Authorized Service Facility.
2. Carburetor is running too rich or too lean.
Page 18 of the Generac 000 & 8 user manual — Section 5 — Notes
Page 18 · click to enlarge
Page 18

Section 5 — Notes

Page 19 of the Generac 000 & 8 user manual — Section 5 — Notes
Page 19 · click to enlarge
Page 19

Section 5 — Notes

Page 20 of the Generac 000 & 8 user manual — THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:
Page 20 · click to enlarge
Page 20

Section 6 — Warranty

GENERAC POWER SYSTEMS “TWO YEAR” LIMITED WARRANTY FOR

GP SERIES PORTABLE GENERATORS

For a period of two years from the date of original sale, Generac Power Systems, Inc. (Generac) warrants its GP Series generators will be free from defects in materials and workmanship for the items and period set forth below. Generac will, at its option, repair or replace any part which, upon examination, inspection and testing by Generac or a Generac Authorized Warranty Service Dealer, is found to be defective. Any equipment that the purchaser/owner claims to be defective must be returned to and examined by the nearest Generac Authorized Warranty Service Dealer. All transportation costs under the warranty, including return to the factory, are to be borne and prepaid by the purchaser/owner. This warranty applies only to Generac GP Series portable generators and is not transferable from original purchaser. Save your proof-of-purchase receipt. If you do not provide proof of the initial purchase date, the manufacturer’s shipping date of the product will be used to determine the warranty period.

WARRANTY SCHEDULE

Consumer applications are warranted for two (2) years. Commercial and Rental applications are warranted for one (1) year or 1000 hours maximum, whichever comes first.

  • CONSUMER APPLICATION YEARS ONE and TWO - 100% (one hundred percent) coverage on Labor and Part(s) listed (proof of purchase and maintenance is required):
  • EngineAll Components
  • AlternatorAll Components
  • COMMERCIAL/RENTAL APPLICATION YEAR ONE – 100% (one hundred percent) coverage on Labor and Part(s) listed (proof of purchase and maintenance is required):
  • EngineAll Components
  • AlternatorAll Components

used for Prime Power in place of utility where utility power service is present or where utility power service does not normally exist. Once a generator has experienced commercial or rental use, it shall thereafter be considered a non-consumer use generator for the purpose of this warranty.

All warranty expense allowances are subject to the conditions defined in Generac’s Warranty Policies, Procedures and Flat Rate Manual.

THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:

  • Generac built portable generators built prior to May 2008.
  • Generac portable generators that utilize non-Generac replacement parts.
  • Costs of normal maintenance and adjustments.
  • Failures caused by any contaminated fuels, oils or lack of proper oil levels.
  • Repairs or diagnostics performed by individuals other than Guardian/Generac authorized dealers not authorized in writing by Generac Power Systems.
  • Failures due, but not limited, to normal wear and tear, accident, misuse, abuse, negligence or improper use. As with all mechanical devices, the Generac engines need periodic
  • part(s) service and replacement to perform as designed. This warranty will not cover repair when normal use has exhausted the life of a part(s) or engine. Failures caused by any external cause or act of God, such as collision, theft, vandalism, riot or wars, nuclear holocaust, fire, freezing, lightning, earth-quake, windstorm, hail,
  • volcanic eruption, water or flood, tornado or hurricane. Damage related to rodent and/or insect infestation.
  • Products that are modified or altered in a manner not authorized by Generac in writing.
  • Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in repair or replacement of the defective part(s).
  • Failure due to misapplication.
  • Telephone, cellular phone, facsimile, internet access or other communication expenses.
  • Living or travel expenses of person(s) performing service, except as specifically included within the terms of a specific unit warranty period.
  • Expenses related to “customer instruction” or troubleshooting where no manufacturing defect is found.
  • Rental equipment used while warranty repairs are being performed.
  • Overnight freight or special shipping costs for replacement part(s).
  • Overtime, holiday or emergency labor.
  • Starting batteries, fuses, light bulbs and engine fluids.

THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. SPECIFICALLY, GENERAC MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. GENERAC’S ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC’S NEGLIGENCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights. You also have other rights from state to state.

  • GENERAC POWER SYSTEMS, INC. P.O. BOX 8
  • Waukesha, WI 53187 Ph: (888) GENERAC (436-3722)
  • Fax: (262) 544-4851 To locate the nearest Authorized Dealer visit our website <a href="http://www.generac.com" rel="nofollow noopener" target="_blank">www.generac.com</a>

Part No. 0G9451 Revision D (10/27/08) Printed in U.S.A.

Manual Part No. 0G8751 Rev D (01/07/10) Printed in U.S.A.

Page 21 of the Generac 000 & 8 user manual — Serie GP Generador portátil de 7.000 y 8.000 vatios
Page 21 · click to enlarge
Page 21

Serie GP Generador portátil de 7.000 y 8.000 vatios

Generac 000 & 8 — Serie GP Generador portátil de 7.000 y 8.000 vatios diagram (page 21)
Fig. 21 · Serie GP Generador portátil de 7.000 y 8.000 vatios
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Engine is running, but no AC output is available.1. Circuit breaker is open. 2. Poor connection or defective cord set. 3. Connected device is bad. 4. Fault in generator.1. Reset circuit breaker. 2. Check and repair. 3. Connect another device that is in good condition. 4. Contact Authorized Service Facility. p.17
Engine is running, but no AC output is available. p.17
Engine runs good but bogs down when loads are connected.1. Short circuit in a connected load. 2. Generator is overloaded. 3. Engine speed is too slow. 4. Shorted generator circuit.1. Disconnect shorted electrical load. 2. See “Don’t Overload the Generator” . 3. Contact Authorized Service Facility. 4. Contact Authorized Service Facility. p.17
Engine runs good but bogs down when loads are connected. p.17
Engine will not start; or starts and runs rough.1. Fuel Shut-off is OFF. 2. Dirty air filter. 3. Out of gasoline. 4. Stale gasoline. 5. Spark plug wire not connected to spark plug. 6. Bad spark plug. 7. Water in gasoline. 8. Over-choking. 9. Low oil level. 10. Excessive rich fuel mixture. 11. Intake valve stuck open or closed. 12. Engine has lost compression.1. Turn Fuel Shut-off to ON. 2. Clean or replace air filter. 3. Fill fuel tank. 4. Drain fuel tank and fill with fresh fuel. 5. Connect wire to spark plug. 6. Replace spark plug. 7. Drain fuel tank; fill with fresh fuel. 8. Put choke knob to No Choke position. 9. Fill crankcase to proper level. 10. Contact Authorized Service Facility. 11. Contact Authorized Service Facility. 12. Contact Authorized Service Facility. p.17
Engine will not start; or starts and runs rough. p.17
Engine shuts down during operation.1. Out of gasoline. 2. Low oil level. 3. Fault in engine.1. Fill fuel tank. 2. Fill crankcase to proper level. 3. Contact Authorized Service Facility. p.17
Engine shuts down during operation. p.17
Engine lacks power.1. Load is too high. 2. Dirty air filter. 3. Engine needs to be serviced.1. Reduce load (see “Don’t Overload the Generator”). 2. Clean or replace air filter. 3. Contact Authorized Service Facility. p.17
Engine lacks power. p.17
Engine “hunts” or falters.1. Choke is opened too soon. 2. Carburetor is running too rich or too lean.1. Move choke to halfway position until engine runs smoothly. 2. Contact Authorized Service Facility. p.17

Ask about the Generac 000 & 8

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Generac 000 & 8

Be the first to ask — other owners or our team will answer.

Original document

Generac 000 & 8 manual PDF

56 pages·7.5 MB·Portable Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…