Gefen delivers innovative, progressive computer and electronics add-on solutions that harness integration, extension, distribution and conversion technologies. Gefen’s reliable, plug-and-play products supplement cross-platform computer systems, professional audio/video environments and HDTV systems of all sizes with hard-working solutions that are easy to implement and simple to operate.
The Gefen 4x1 DPKVM Switcher
Easily switch between four computers using DisplayPort with the Gefen 4x1 DPKVM Switcher.
The rack-mountable Gefen 4x1 DPKVM Switcher offers an economical solution for switching between four different computers to one display location. In addi- tion, USB peripherals and audio are carried at the same time from each source making this a very versatile solution.
Eliminating the need to purchase many displays, keyboards and other acces- sories for each computer in a studio or professional environment, this versatile solution saves money, supports both Mac and PC-type computers, and offers uncluttered and increased desktop space.
The 4x1 DPKVM Switcher outputs are: One DisplayPort, two USB 2.0 ports (used for keyboard, mouse and other USB 2.0 peripherals) and an analog L/R audio. This Switcher can be controlled using front panel discrete switching, the included IR Remote control, or the RS-232 port for switching automation.
The 4x1 DPKVM Switcher is compatible with all operating systems using Display- Port and USB.
Connect the four included 6-foot DisplayPort cables between the computers and the Switcher inputs. Connect the four included USB cables between the computers and the USB inputs. Connect the four included audio cables between the computers and the audio inputs. Connect the Switcher output to the monitor using a DisplayPort cable. Connect the Switcher USB outputs to the USB pe- ripherals. Connect the Switcher audio cables to the audio devices. Connect the included 5V DC locking power supply to the 4x1 Switcher and connect the AC power cord to an available electrical outlet. The currently selected source will be displayed.
Gefen · How It Works

READ THESE NOTES BEFORE INSTALLING OR
OPERATING THE 4X1 DPKVM SWITCHER

(1) 4x1 DPKVM Switcher (4) 6 ft. DisplayPort cables (4) 6 ft. USB 2.0 cables (A - B) (4) 6 ft. 3.5 mm mini-stereo audio cables (1) IR Remote Control Unit (EXT-RMT-4IR) (1) 5V / 4A DC Locking Power Supply (EXT-PS54AULP) (1) Set Rack ears (1) User Manual
Features · Package Includes


4 2 1 3
Front Panel

1 Input Indicators (1 - 4) Each of these LED indicators glows bright blue according to the input selection (see Input Buttons, below)
2 IR Receives IR signals from the included IR Remote Control Unit.
3 Input Buttons (1 - 4) Pressing each of these buttons selects the desired input source (1-4). 4 Power This LED indicator will glow bright red when the unit is powered.


8 9 6 7
Back Panel

1 5V DC Connect the included 5V DC locking power supply to this receptacle.
2 DP In 1 - In 4 Each of these ports will accept a standard DisplayPort source device.
3 Ext IR Connect an IR extender cable to this port.
4 USB Out (1 - 2) Connect USB devices (e.g. mouse devices, keyboards, etc.) to these ports.
5 Ethernet Use an Ethernet cable to connect the Switcher to a network in order to communicate via Telnet.
6 RS-232 Serial Port This port is used for serial communication using an RS-232 control device. For details, refer to page 14.
7 USB In (1 - 4) Connect USB source devices to these ports.
8 DP Out This port will accept a single standard DisplayPort output device. The currently selected DisplayPort input source will be output via this port.
9 Audio Out Connect an audio output device to this connector using a 3.5 mm mini-stereo cable. The audio output will be for the currently selected input source.
10 Audio IN Connect audio source device to this port using the 3.5 mm mini-stereo cable.


1 Activity Indicator This LED will be activated momentarily each time a button is pressed.
2 Source Selection Buttons (1 - 4) These buttons are used to select which source is routed to a monitor.
Layout and Description

The Remote Control unit ships with two batteries. One battery is required for operation and the other battery is a spare.

Installing the Battery · Battery Slot

Setting the IR Channel
In the event that IR commands from other remote controls interfere with the supplied IR Remote Control unit, changing the IR Remote Control’s IR channel will fi x the problem. The IR Remote Control unit has a bank of DIP switches used for setting the IR channel. The DIP switch bank is located underneath the battery cover.

Left: Picture of the opened rear battery compartment of the IR remote showing the exposed DIP Switch bank between the battery chambers.
Corresponding DIP Switch Settings for each IR Channel
IR Channel 0 (default)
ON IR Channel 1
ON
ON
It is important that the IR channel on the Remote Control unit, matches the IR channel set on the 4x1 DPKVM Switcher. For example, if both DIP switches on the IR Remote Control unit are set to IR channel 0 (both DIP switches down), then the 4x1 DPKVM Switcher must also be set to IR channel 0. See page 21 on how to change the IR channel on the 4x1 DPKVM Switcher.
IR Channel 2 · IR Channel 3

How to Connect the 4x1 DPKVM Switcher
1 Connect up to four (4) DisplayPort source devices to the DisplayPort inputs on the back panel of the Switcher using DisplayPort cables.
2 Connect a DisplayPort-supported display to the DisplayPort output on the back panel of the Switcher.
a OPTIONAL: To use the RS-232 communication feature, connect an RS-232 cable between the Switcher and RS-232 host controller.
b OPTIONAL: To communicate with the Switcher using Telnet, connect an Ethernet cable from the Ethernet jack on the back of the Switcher to the network. See page 24 for more information on using the Telnet feature.
c OPTIONAL: To extend the range of the IR control, connect an IR Extender (Gefen part no. EXT-RMT-EXTIR) to the back of the Switcher.
3 Connect the included 5V locking power supply to the power receptacle on the 4x1 DPKVM Switcher
4 Connect the opposite end of the power supply to an open wall socket power source.
Wiring Diagram for the 4x1 DPKVM Switcher
DISPLAYPORT CABLE

Computer · Powered Speakers

Front Panel Buttons and LED Indicators
The front panel of the 4x1 DPKVM Switcher has a set of four (4) LED indicators, displaying which input (source) is being displayed. Each of these LED indicators corresponds to one of the push-buttons on the front panel.
Switching sources using the front panel buttons
1 Press button 3 on the front panel of the 4x1 DPKVM Switcher.
2 The LED indicator for input 3 will glow bright blue on the front panel.




Switching sources using the IR Remote Control
1 Press button 1 on the IR Remote Control Unit. The Activity Indicator on the IR Remote Control Unit will glow yellow, indicating that a button was pressed.
2 The LED indicator for input 1 will glow bright blue.





Switching sources using RS-232
Confi gure the Switch for use with RS-232 (see page 14 for details).
1 Use the command r 4 to route the Switcher to Input 4. See page 15 for important information on RS-232 commands. RS-232 commands are case-sensitive.
2 The LED indicator for Input 4 will glow bright blue on the front panel.


r 4 Route to Input 4
Switching sources using Telnet
Confi gure the Switch for use with Telnet. See page 24 for details.
1 Use the command r 2 to route the Switcher to Input 2.
2 The LED indicator for Input 2 will glow bright blue.


Route to Input 2

Only pins 2 (Receive), 3 (Transmit), and 5 (Ground) are used for communication. A null-modem adapter should not be used with this product.
5 4 3 2 1
1 2 3 4 5
9 8 7 6
6 7 8 9
Only Pins 2 (RX), 3 (TX), and 5 (Ground) are used on the RS-232 serial interface
Bits per second 19200
Data bits 8
Parity None
Stop bits 1
Flow Control None
Serial Port Settings

All RS-232 commands are case-sensitive and must be entered in lowercase. Each command must be preceded by the ‘#’ character. A carriage return must also be appended to every command.
Example:
#get_pass Prompts for the Telnet password
#get_user_name Prompts for the Telnet username
#ipconfi g Displays all TCP/IP settings
#rstip Sets IP confi guration to default settings
#set_http_port Sets the Web server listening port
#set_pass Sets the Telnet password
#set_telnet_port Sets the Telnet listening port
#set_user_name Sets the Telnet user name
#sgateway Specifi es the new gateway
#sipadd Specifi es a new IP address
#snetmask Specifi es a new net mask
#use_telnet_pass Toggles Telnet password prompt
The #GET_PASS command prompts for the Telnet password.

The #GET_USER_NAME command prompts for the Telnet username.
The #IPCONFIG command displays all TCP/IP settings.
The #RSTIP command resets the IP confi guration to the default settings.

The #SET_HTTP_PORT command sets the Web server listening port.
param1 Port [0 - 255]
The #SET_PASS command sets Telnet password.
The maximum length of the password string is 20 characters.
The #SET_TELNET_PORT command sets the Telnet server listening port.
param1 Port [0 - 255]

The #SET_USER_NAME command sets the Telnet user name.
The maximum length of the username string is 20 characters.
Specifi es the new IP gateway. Dot-decimal notation must be used when specify- ing the IP address. A reboot is required after the new IP gateway address has been assigned.
#sgateway param1.param2.param3.param4
param1 Gateway address [0 - 255]
param2 Gateway address [0 - 255]
param3 Gateway address [0 - 255]
param4 Gateway address [0 - 255]
Example:
#sgateway 192.168.1.1

The #SIPADD command specifi es a new IP address. Dot-decimal notation must be used when specifying the IP address. A reboot is required after the new IP address is set.
#sipadd param1.param2.param3.param4
param1 IP address [0 - 255]
param2 IP address [0 - 255]
param3 IP address [0 - 255]
param4 IP address [0 - 255]
Example:
#sipadd 192.168.2.240
The #SNETMASK command specifi es a new net mask. Dot-decimal notation must be used when specifying the IP address. A reboot is required after the new IP address is set.
#snetmask param1.param2.param3.param4
param1 IP address [0 - 255]
param2 IP address [0 - 255]
param3 IP address [0 - 255]
param4 IP address [0 - 255]
Example:
#snetmask 255.255.255.0
#SIPADD Command · #SNETMASK Command

The #USE_TELNET_PASS command enables / disabled the use of a Telnet password during the login process.
param1 State [0 - 1]
#activebolo Activates the bootloader
#fadefault Resets the Switcher to the default routing state
#irrmtadd Sets the IR address for the Switcher
#lockpower Toggles the lock power state
#stbymode Toggles Standby (power OFF) Mode
The #ACTIVEBOLO function activates the bootloader. This command is required in order to begin the fi rmware update procedure. See page 26 for details.
This command must be executed twice, in order to active the bootloader.

The #FADEFAULT function will reset the Switcher to the default routing settings.
The #IRRMTADD sets the IR channel. The IR channel for the Switcher and the IR Remote Control Unit must be the same.
param1 State [0 - 3]
0 IR channel 0
1 IR channel 1
2 IR channel 2
3 IR channel 3

The #LOCKPOWER enables/disables the power lock state. Enabling this feature will store the 5V status for each input prior to shutting the unit down. This preserves the 5V state when the unit is restarted.
param1 State [0 - 1]
0 Disable Power Lock
1 Enable Power Lock
The #STBYMODE command toggles the Standby Mode state. When the Switcher is powered OFF (not unplugged), then the unit is in Standby Mode. Executing this command from Standby Mode will power ON the Switcher.
param1 Mode [0 - 1]

The following command does not require the ‘#’ character. A carriage return must be added to the end of the command.
The R command switches to the specifi ed input.
param1 DisplayPort Input [1 - 4]

The Gefen 4x1 DPKVM Switcher supports Telnet for controlling the Switcher over a network. To access this feature, an IP address, subnet, gateway, and port numbers need to be set correctly. Consult the network administrator to obtain the proper IP address and settings for this product to properly communicate with the Switcher over a network.
The Telnet control must be confi gured using RS-232 commands. Once properly confi gured, enter the IP address that was assigned to the Switcher using a terminal program or other Telnet client.
=================================================== GEFEN DISPLAY PORT 441 FW version: 1.3 ===================================================
TCP/IP settings
MAC addr = 00:1C:91:02:40:00 IP addr = 192.168.0.70 Net Mask = 255.255.255.0 Gateway = 192.168.0.1 Web Server Port = 80 Telnet Server Port = 23 Telnet password on login is set to ON
#ipconfi g

#sipadd 192.168.2.234
After setting the IP address, power-cycle the Switcher for the changes to take effect.
6 Specify the IP of the Switcher in the Telnet client. In this example, the IP address is set to 192.168.2.234. Once connected to the Switcher, the Telnet client will display a screen similar to the following:
Welcome to DP441 Telnet Server You are user number 1 of 3 allowed. You will be disconnected after 10 minutes of inactivity.
Type Cmd:
By default, the user name and password options are enabled by use of the #use_telnet_pass command (see page 20). Once this command is enabled, the Switcher will prompt for both the user name and password. The password cannot be disabled from the login process. Once logged in, the Type Cmd prompt will be displayed.
The Telnet interface uses the same commands and syntax that are used with RS-232 control. See the command list, starting on page 15.

Any terminal emulation program can be used to perform the upgrade process. The instructions below is outlined for Windows® HyperTerminal.
The following will be displayed on the screen:
================== Main Menu ========================
Download new program 1 Cancel 2 =====================================================
Waiting for the fi le to be sent ... (press ‘a’ to abort)
Firmware Update Procedure · Programming Completed Successfully!

Installing the Rack Ears
Rack mount ears are provided for installation of this unit into a 1U rack mount space.














Front of unit · Rear of unit

Maximum Pixel Clock 360 MHz
Video Input Connectors (4) DisplayPort, female
Video Output Connector (1) DisplayPort, female
USB Input Connectors (4) USB 2.0 Type B
USB Output Connectors (2) USB 2.0 Type A
Audio Input Connectors (4) 3.5 mm mini-stereo
Audio Output Connector (1) 3.5 mm mini-stereo
RS-232 Connector (1) DB-9, female
Ethernet Connector (1) RJ-45, shielded
IR Extender Connector (1) 3.5 mm mini-stereo
Power Supply 5V DC
Power Consumption 10W (max.)
Dimensions 17.1” W x 1.75” H x 4.25” D
Shipping Weight 4 lbs.

Gefen warrants the equipment it manufactures to be free from defects in material and workmanship.
If equipment fails because of such defects and Gefen is notifi ed within two (2) years from the date of shipment, Gefen will, at its option, repair or replace the equipment, provided that the equipment has not been subjected to mechanical, electrical, or other abuse or modifi cations. Equipment that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair. Such repairs are warranted for ninety (90) days from the day of reshipment to the Buyer.
This warranty is in lieu of all other warranties expressed or implied, including without limitation, any implied warranty or merchantability or fi tness for any particular purpose, all of which are expressly disclaimed.
The information in this manual has been carefully checked and is believed to be accurate. However, Gefen assumes no responsibility for any inaccuracies that may be contained in this manual. In no event will Gefen be liable for direct, indirect, special, incidental, or consequential damages resulting from any defect or omission in this manual, even if advised of the possibility of such damages. The technical information contained herein regarding the features and specifi cations is subject to change without notice.
For the latest warranty coverage information, refer to the Warranty and Return Policy under the Support section of the Gefen Web site at www.gefen.com
Please register your product online by visiting the Register Product page
under the Support section of the Gefen Web site.

20600 Nordhoff St., Chatsworth CA 91311
www.gefen.com support@gefen.com
This product uses UL listed power supplies.
Rev A2
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.