BEFORE YOU BEGIN Read these instructions completely and carefully.
manufacturer. If you have any questions, contact the manufacturer. B. Before servicing or cleaning unit, switch power off at
the service panel and lock service panel to prevent power from being switched on accidentally. If the service panel cannot be locked, fasten a tag or prominent warning label to the panel. ADVERTISSEMENT : POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES, IL FAUT OBSERVER LES REGLES SUIVANTES: A. Utiliser cet appareil uniquement de la maniére prévue
par le fabricant. En cas de question, consulter le fabricant. B. Avant toute intervention ou nettoyage, couper


POWER SUPPLY IMPORTANT – (Please read carefully) WARNING: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. ADVERTISSEMENT : POUR DES RAISONS DE SÉCURITÉ, CET APPAREIL DOIT ÊTRE CORRECTEMENT MIS À LA TERRE. Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordinances.
Grounding instructions The grounding conductor must be connected to a ground metal, permanent wiring system, or an equipment-grounding terminal or lead on the hood. WARNING: The improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded. ADVERTISSEMENT : Le mauvais branchement du fil de mise à la terre peut causer un choc électrique. En cas de doute, consulter un électricien qualifié ou un technicien pour déterminer si l’appareil est à la terre.

DUCT FITTINGS Use this chart to compute maximum permissable lengths for duct runs to outdoors.
Total Equivalent Quantity Equivalent Duct Piece Dimensions Length* Used Length Round, 1 ft. straight (per foot length)
3-1/4” x 12” 1 ft. 3-1/4” x 24” (per foot straight length)
6” Round 90° elbow 15 ft.
Flexible ducting: If flexible metal ducting is used, all the equivalent feet values in the table should be doubled. The flexible metal duct should be straight and smooth and extended as much as possible.
6” Round 45° elbow 8 ft.
3-1⁄4” x 12” 90° elbow 11 ft.
3-1/4” x 12” or 45° elbow 6 ft.
DO NOT use flexible plastic ducting.
3-1/4” x 12” 90° flat elbow 24 ft.
NOTE: Any home ventilation system, such as a ventilation hood, may interrupt the proper flow of combustion air and exhaust required by fireplaces, gas furnaces, gas water heaters and other naturally vented systems. To minimize the chance of interruption of such naturally vented systems, follow the heating equipment manufacturer’s guidelines and safety standards such as those published by NFPA and ASHRAE.
6” round to 3-1/4” x 12” or 3-1/4” x 24” transition 1 ft.
3-1/4” x 12” to 6” round transition 8 ft.
6” round to 3-1/4” x 12” or transition 90° elbow 16 ft.
3-1/4” x 12” to 6” round round transition 90° elbow 17 ft.
6” round wall cap with damper 30 ft.
This Hood Must Use a
6” Round Duct. It Can Transition To
3-1/4” x 12” wall cap with damper 30 ft.
3-1/4” x 12” Duct
6” Round roof cap 26 ft.
6” Round roof vent 26 ft.
*Actual length of straight duct plus duct fitting equivalent. Equivalent length of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reflect requirements for good venting performance with any ventilation hood.
Total Duct Run


Tape measure Knife Spirit level Wire cutter/stripper Wire nuts Electric drill with 1/8" and 3/8" bits Phillips and flat blade screwdrivers Hammer Pliers Safety glasses Duct tape Tape to mount template Gloves to protect against sharp edges 120V 60Hz. 15 or 20 Amp, 2 wire with
ground Properly grounded branch circuit Strain relief for junction cover 6" round metal duct, length to suit
installation Saw or jig saw Conduit for house wiring


Actual *Possible Celing *Possible VENTED RECIRCULATING Height Installation Height Installation Height
7’11” 24” to 27” 24” to 25”
8’ 0” 24” to 28” 24” to 26”
8’ 1” 24” to 30” 24” to 27”
8’ 2” 24” to 30” 24” to 28”
8’ 3” 24” to 30” 24” to 29”
8’ 4” 24” to 30” 24” to 30”
8’ 5” 24” to 30” 24” to 30”
8’ 6” 24” to 30” 24” to 30”
8’ 7” 24” to 30” 24” to 30”
8’ 8” 24” to 30” 24” to 30”
8’ 9” 24” to 30” 24” to 30”
24” Min. 30” Max.
8’ 10” 24” to 30” 24” to 30”
8’ 11” 24” to 30” 24” to 30”
9’ 0” 24” to 30” 24” to 30”
9’ 1” 24” to 30” 24” to 30”
9’ 2” 24” to 30” 24” to 30”
9’ 3” 24” to 30” 24” to 30”
36” Min.
9’ 4” 24” to 30” 24” to 30”
9’ 5” 24” to 30” 24” to 30”
9’ 6” 24” to 30” 24” to 30”
9’ 7” 25” to 30” 24” to 30”
The vent hood must be installed 24” min. and 30” max. above the cooking surface. The hood installation height, from the cooking surface to the bottom of the hood, depends upon ceiling height.
9’ 8” 26” to 30” 24” to 30”
9’ 9” 27” to 30” 24” to 30”
9’ 10” 28” to 30” 24” to 30”
9’ 11” 29” to 30” 25” to 30”
10’ 30” 26” to 30”
*Based on 36” countertop height.
*20” Min.
24” Min.
*The cabinet must measure at least 20” from the bottom frame to the inside top. The hood housing will occupy the interior cabinet space.


Locate the hardware accessory box packed with the hood and check contents.
4 Phillips head decorative screws to secure duct cover
TOP CABINET TEMPLATE Align template with centerline and tape to bottom of the cabinet.

INSTALL FRAMING FOR HOOD SUPPORT IMPORTANT — Framing must be capable of supporting 100 lbs.
Determine the exact location of the vent hood.
surface. Add hood installation height determined on page 7. Mark that location. – Use a level to draw a straight pencil line on the wall.
6” min. opening for ductwork
8" Min. Opening for Ductwork
3-3/4” centerline to wall
6-1/2” dia. hole
min. above top mounting bracket
holes FOR WALL VENT DUCT
1" x 6" Min. Mounting
1” x 6” min. mounting
Drill 1/8" Pilot Holes
Drill 1/8" Pilot Holes
Drill 1/8" Pilot Holes Drill 1/8" Pilot Holes
Drill 1/8" Pilot Holes
Drill 1/8" Pilot Holes
PENCIL LINE INDICATING
BOTTOM OF THE HOOD.
Centerline of Installation Space
– Tape the template in position along the penciled
line. CHECK TO BE SURE THE TEMPLATE IS LEVEL.

INSTALL DUCT BRACKET
The duct bracket must be intalled against the ceiling. This bracket will hold the duct cover in place at the top. Secure the bracket to the ceiling and wall:




Duct tape over seam and screw Screw
PRUDENCE : Il ne faut pas utiliser de vis autoraurdeuses à la connexion du collet de la hotte. Ceci empêcherait le bon fonctionnement du registre. N’utiliser que du ruban adhésif pour assurer l’étanchéité du raccord.
Verify that power is turned off at the source. WARNING: If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use U.L. approved anti-oxidant compound and aluminum-to-copper connectors. ADVERTISSEMENT : Si la maison n’est pas câblee avec deux fils et un fil de terre, l’installateur doit installer un fil de terre. Quand les fils sont en aluminium, il faut prendre soin d’utiliser des connecteurs aluminium à cuivre avec une pâte antioxydante approuvée par U.L.
Air flow


The inside duct piece must slip into the folded ends of the outer section.

Install 2 bottom duct cover screws

INSTALL FRAMING FOR HOOD SUPPORT IMPORTANT: Framing must be capable of supporting 100 lbs.
1" x 6" Min. Mounting
1” x 6” min. mounting
Drill 1/8" Pilot Holes
Drill 1/8" Pilot Holes
Drill 1/8" Pilot Holes Drill 1/8" Pilot Holes
Centerline of Installation Space
Drill 1/8" Pilot Holes
Drill 1/8" Pilot Holes
PENCIL LINE INDICATING
BOTTOM OF THE HOOD.


This vent hood must be secured to the horizontal support or wall studs.

MOUNT THE HOOD
Install a wood screw
on each side of the

Verify that power is turned off at the source. WARNING: If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use U.L. approved anti-oxidant compound and aluminum-to-copper connectors. ADVERTISSEMENT Si la maison n’est pas câblee avec deux fils et un fil de terre, l’installateur doit installer un fil de terre. Quand les fils sont en aluminium, il faut prendre soin d’utiliser des connecteurs aluminium à cuivre avec une pâte antioxydante approuvée par U.L.
The inside duct piece must slip into the folded ends on the outer section.
Install 2 bottom duct cover screws



Charcoal filter • Remove protective film on the filters.
Metal grease filters • Tip filters into the slots at the rear of the opening. Lift the filter lock and pull forward until the filter rests in the slots.

DUCTWORK, WIRING
This hood may be installed beneath a wall-mounted cabinet. • If the cabinet has been installed, it must be removed so that wall framing supports can be added.
20” Min.
3-3/4” centerline to wall
24” Min.
Drill 1/8" Pilot Holes
Drill 1/8" Pilot Holes
Drill 1/8" Pilot Holes Drill 1/8" Pilot Holes
Drill 1/8" Pilot Holes
Drill 1/8" Pilot Holes
PENCIL LINE INDICATING
BOTTOM OF THE HOOD.


INSTALL FRAMING FOR HOOD SUPPORT IMPORTANT: Framing must be capable of supporting 100 lbs.
1" x 6" Min. Mounting
1” x 6” min. mounting
Centerline of Installation Space



The top center screw on both sides of the hood can be used to close up any noticeable gaps at the outside edges. See illustration.
Cabinet Frame.
Equivalent to Depth of Cabinet

COMPLETE THE INSTALLATION AND CONNECT DUCTWORK
Install a wood screw
on each side of the
Install 2 Screws into
Install original top screws
If there is a noticeable gap between the hood and the bottom of the cabinet on the sides: • Slide canopy forward and install original top screws through the bottom of the hood and into cabinet bottom or frame. NOTE: Install wood filler blocks if necessary to accept the screws.
mounting frame · Each Side Bracket


Install 2 Wood Screws

For Monogram® local service in your area, call 1.800.444.1845.
Pub. No. 49-80267
Printed in Italy