EN
GE logo
Official user manual

GE PFMN440

156 pages·12.8 MB·Clothes Dryer·PDF·ENDEITNLJA
GE PFMN440
Table of Contents 1 sections 49-90396 ENv11.pdf ShowHide
Page 1 of the GE PFMN440 user manual — 234D1050P003 49-90396-1 08/06/10 GE
Page 1 · click to enlarge
Page 1

GEAppliances.com

Profile

Dryers

Safety Instructions 2–4

Owner’s Manual & Installation Instructions

Operating Instructions Controls 5–8 Cycle Options 9, 10 Smart Appliance 13 Dryer Features 10, 11 Quick Start Guide 5 Settings Option 10 Using the Dryer 12

PFDS450 PFDS455 PFDN440 PFDN445 PFMS450 PFMS455 PFMN440 PFMN445

Installation Instructions Before You Begin 14, 15 Connecting the Inlet Hoses 17 Connecting a Gas Dryer 18–21 Connecting an Electric Dryer 22–24 Exhausting the Dryer 25–31 Final Setup 32 Installing the Pedestal 43–45 Location of your Dryer 15, 16 Reversing the Door Swing 33–39 Stacking the Washer and Dryer 40–42

Sécheuses

Profile

Manuel d’utilisation

et d’installation

La section française commence à la page 51

Secadoras

Troubleshooting Tips 46–49

Profile

Consumer Support Consumer Support Back Cover Warranty (Canada) 51 Warranty (U.S.) 50

Manual del propietario

e instalación

La sección en español empieza en la página 103

SAVE THESE INSTRUCTIONS

Write the model and serial numbers here:

Model # ______________

Serial #________________

They are on the label on the front of the dryer behind the door.

234D1050P003 49-90396-1 08/06/10 GE

Page 2 of the GE PFMN440 user manual — Exhaust/Ducting
Page 2 · click to enlarge
Page 2

n Do not store or use gasoline or other

n Installation and service must be

flammable vapors and liquids in the vicinity of this or any other appliance.

performed by a qualified installer, service agency or the gas supplier.

WHAT TO DO IF yOU SMELL GAS:

Do not try to light a match, or cigarette, or turn on any gas or electrical appliance.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions carefully.

Do not touch any electrical switch; do not use any phone in your building.

If you cannot reach your gas supplier, call the fire department. 5

Clear the room, building or area of all occupants.

California Safe Drinking Water and Toxic Enforcement Act

This act requires the governor of California to publish a list of substances known to the state to cause cancer, birth defects or other reproductive harm and requires businesses to warn customers of potential exposure to such substances.

Gas appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde and soot, caused primarily by the incomplete combustion of natural gas or LP fuels.

Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances can be minimized further by properly venting the dryer to the outdoors.

PROPER INSTALLATION

This dryer must be properly installed and located in accordance with the Installation Instructions before it is used. Installation Instructions are included in the back of this manual.

n Properly ground dryer to conform with all

Exhaust/Ducting

governing codes and ordinances. Follow details in Installation Instructions.

Dryers MUST be exhausted to the outside to prevent large amounts of moisture and lint from being blown into the room.

n Install or store where it will not be exposed to

temperatures below freezing or exposed to water or weather.

Use only rigid metal 4″ diameter ductwork inside the dryer cabinet. Use only UL approved rigid metal or flexible metal 4-in diameter ductwork for exhausting to the outdoors. Never use plastic or other combustible, easy-to-puncture ductwork.

n Connect to a properly rated, protected and sized

power supply circuit to avoid electrical overload.

n Remove all sharp packing items and dispose of

all shipping materials properly.

For complete details, follow the Installation Instructions.

Page 3 of the GE PFMN440 user manual — WHEN USING YOUR DRYER
Page 3 · click to enlarge
Page 3

GEAppliances.com

WARNING!

YOUR LAUNDRY AREA

n Keep the area underneath and around your

n Keep the area around the exhaust opening

appliances free of combustible materials, (lint, paper, rags, etc.), gasoline, chemicals and other flammable vapors and liquids.

and adjacent surrounding areas free from the accumulation of lint, dust and dirt.

n Keep all laundry aids (such as detergents,

n Keep the floor around your appliances clean

bleaches, etc.) out of the reach of children, preferably in a locked cabinet. Observe all warnings on container labels to avoid injury.

and dry to reduce the possibility of slipping.

n Close supervision is necessary if this appliance is

used by or near children. Do not allow children to play on, with or inside this or any other appliance.

n Never climb on or stand on the dryer top.

WHEN USING YOUR DRYER

n Never reach into the dryer while the drum is

n The laundry process can reduce the flame

moving. Before loading, unloading or adding clothes, wait until the drum has completely stopped.

retardancy of fabrics. To avoid such a result, carefully follow the garment manufacturer’s care instructions.

n Clean the lint filter before each load to prevent lint

n Do not dry articles containing rubber, plastic

accumulation inside the dryer or in the room. DO NOT OPERATE THE DRyER WITHOUT THE LINT FILTER IN PLACE.

or similar materials such as padded bras, tennis shoes, galoshes, bath mats, rugs, bibs, baby pants, plastic bags, pillows, etc. that may melt or burn. Some rubber materials, when heated, can under certain circumstances produce fire by spontaneous combustion.

n Do not wash or dry articles that have been

cleaned in, washed in, soaked in or spotted with combustible or explosive substances (such as wax, oil, paint, gasoline, degreasers, dry-cleaning solvents, kerosene, etc.). These substances give off vapors that may ignite or explode. Do not add these substances to the wash water. Do not use or place these substances around your washer or dryer during operation.

n Do not store plastic, paper or clothing that may

burn or melt on top of the dryer during operation.

n Garments labeled Dry Away from Heat or Do Not

Tumble Dry (such as life jackets containing Kapok) must not be put in your dryer.

n Do not dry fiberglass articles in your dryer.

n Do not place items exposed to cooking oils in

Skin irritation could result from the remaining particles that may be picked up by clothing during subsequent dryer uses.

your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a clothes load to catch fire.

n To minimize the possibility of electric shock, unplug

n Any article on which you have used a cleaning

this appliance from the power supply or disconnect the dryer at the household distribution panel by removing the fuse or switching off the circuit breaker before attempting any maintenance or cleaning (except the removal and cleaning of the lint filter). NOTE: Pressing START/PAUSE or POWER does NOT disconnect the appliance from the power supply.

solvent or that contains flammable materials (such as cleaning cloths, mops, towels used in beauty salons, restaurants or barber shops, etc.) must not be placed in or near the dryer until solvents or flammable materials have been removed. There are many highly flammable items used in homes such as acetone, denatured alcohol, gasoline, kerosene, some household cleaners, some spot removers, turpentines, waxes, wax removers and products containing petroleum distillates.

n If you see water on the floor around the dryer,

call for service.

Page 4 of the GE PFMN440 user manual — READ AND FOLLOW THIS SAFETY INFORMATION cAREFULLY. SAVE THESE INSTRUCTIONS
Page 4 · click to enlarge
Page 4

WARNING!

WHEN USING YOUR DRYER (cont.)

n Never attempt to operate this appliance if it is

n Do not use steam cycles on new clothes without

damaged, malfunctioning, partially disassembled, or has missing or broken parts, including a damaged cord or plug.

first washing.

n You may wish to soften your laundered fabrics

or reduce the static electricity in them by using a dryer-applied fabric softener or an anti-static conditioner. We recommend you use either a fabric softener in the wash cycle, according to the manufacturer’s instructions for those products, or try a dryer-added product for which the manufacturer gives written assurance on the package that their product can be safely used in your dryer. Service or performance problems caused by use of these products are the responsibility of the manufacturers of those products and are not covered under the warranty of this appliance.

n The interior of the machine and the exhaust duct

connection inside the dryer should be cleaned at least once a year by a qualified technician. See the Sorting and Loading Hints section on page 12.

n If yours is a gas dryer, it is equipped with an

automatic electric ignition and does not have a pilot light. DO NOT ATTEMPT TO LIGHT WITH A MATCH. Burns may result from having your hand in the vicinity of the burner when the automatic ignition turns on.

n Do not open the dryer door during steam cycles.

The steam is very hot and it will continue to exhaust from the port for several seconds after opening. Do not touch the steam port after a steam cycle.

n Never attempt to use the Steam Dewrinkle or

Steam Refresh cycles without clothes in the drum. Additionally, it is highly recommended to select the appropriate load size for best results. Selecting large load cycles for small loads may result in wetting of clothes, and selecting small load cycles for large loads may result in poor dewrinkling performance.

n Do not use a steam cycle with items such

as wool, leather, silk, lingerie, foam products or electric blankets.

WHEN NOT USING YOUR DRYER

n Grasp the plug firmly when disconnecting this

n Before discarding a dryer, or removing it from

appliance to avoid damage to the cord while pulling. Place the cord away from traffic areas so it will not be stepped on, tripped over or subjected to damage.

service, remove the dryer door to prevent children from hiding inside.

n Do not tamper with controls.

n Do not attempt to repair or replace any part of

this appliance or attempt any servicing unless specifically recommended in this Owner’s Manual or in published user-repair instructions that you understand and have the skills to carry out.

READ AND FOLLOW THIS SAFETY INFORMATION cAREFULLY. SAVE THESE INSTRUCTIONS

Page 5 of the GE PFMN440 user manual — Select a cycle by turning the Cycle Knob. 2
Page 5 · click to enlarge
Page 5

About the dryer control panel. GEAppliances.com

INSTRUcTIONS before operating this appliance.

Throughout this manual, features and appearance may vary from your model. Quick Start

GE PFMN440 — About the dryer control panel. GEAppliances.com diagram (page 5)
Fig. 1 · About the dryer control panel. GEAppliances.com

If the screen is dark, press the POWER button to “wake up” the display.

If you selected a TIME DRy CyCLE - select your heat setting and the amount of time you want your items to dry by using the cursor buttons. Then press the START/PAUSE button.

Select a cycle by turning the Cycle Knob. 2

If you selected a SENSOR CyCLE – just press the START/PAUSE button. 3

Push to Lock Control Hold 3 Secs to Unlock

DEWRINKLE WARM UP TIMED DRY

Push to Lock Control Hold 3 Secs to Unlock

Power Press to “wake up” the display. If the display is active, press to turn the dryer off.

Page 6 of the GE PFMN440 user manual — 49-90396 ENv11.pdf
Page 6 · click to enlarge
Page 6

About the dryer control panel.

Dry Cycles The dry cycle controls the cycle time for the drying process. The chart below will help you match the dry setting with the loads.

COTTONS For cottons and most linens.

NORMAL/ For loads consisting of cottons and poly-blends. MIXED LOAD

WRINKLE FREE For wrinkle-free/easy care and permanent press items.

ACTIVE WEAR Clothing worn for active sports exercise and some casual wear. Fabrics include new technology finishes and stretch fibers such as Spandex.

DELICATES For lingerie and special-care fabrics.

SPEED DRY For small loads that are needed in a hurry, such as sports or school uniforms. Can also be used if the previous cycle left some items damp, such as collars or waistbands.

STEAM For slightly wrinkled dry garments. Significantly reduces wrinkles on 1–5 garments. REFRESH Selecting a higher number of garments for the cycle (e.g., selecting 5-garment load for a 1-garment load) may result in excessive wetting of clothes. After the STEAM REFRESH Cycle, the unit will beep and display “Garments Ready” and “0:00.” If the unit is not turned off or if the door is not opened, the dryer will continue to tumble for 30 minutes. At the end of 30 minutes, it will display “0:00” and “Cycle Complete.” NOTE: When STEAM REFRESH is selected, “EXTENDED TUMBLE” will automatically turn on and cannot be turned off. A single extremely light fabric item may need to have an additional item included in the steam refresh cycle to achieve optimum results.

DEWRINKLE For removing wrinkles from items that are dry or slightly damp. This cycle is not reccomended for delicate (on some models) fabrics.

STEAM For use with larger loads than STEAM REFRESH. Ideal for loads left in dryer for an extended DEWRINKLE time. Selecting a larger cycle than needed (e.g., selecting Large Load for a half-full dryer) (on some models) may result in excessive wetting of clothes.

WARM UP Provides 10 minutes of warming time to warm up clothes.

My Cycle (on some models)

MY CYCLE Press to use, create or modify custom dry cycles.

Timed Dry Use to set your own dry time. TIMED DRy is also recommended for small loads. To use TIMED DRy: 1. Turn dry cycle dial to TIMED DRy. 2. Select the drying time by pressing the ▲and ▼buttons. You can increase the time in 10-minute increments up to 2 hours, 5 minutes. 3. Select the DRy TEMP. 4. Close the door. 5. Press START/PAUSE.

Sensor Dry The sensor continuously monitors the amount of moisture in the load. When the moisture in your clothes reaches your selected dry level, the dryer will stop.

EXTRA DRY Use for heavy-duty fabrics or items that should be very dry, such as towels.

MORE DRY Use for heavy or mixed type of fabrics.

DRY Use for normal dryness level suitable for most loads. This is the preferred cycle for energy saving.

LESS DRY Use for lighter fabric (ideal for ironing).

DAMP For leaving items partially damp.

Sensor Cycles · Timed Dry Cycles · (on some models)

Page 7 of the GE PFMN440 user manual — Display
Page 7 · click to enlarge
Page 7

GEAppliances.com

Dry Temp You can change the temperature of your dry cycle.

ANTI-BACTERIAL This option may only be used with COTTONS or MIXED LOAD cycles. This option reduces certain types of bacteria by 99.9%, including: Staphylococcus aureus, Pseudomonas aeruginosa and Klebsiella pneumoniae*. The anti-bacterial process occurs when high heat is used during a portion of this drying cycle. NOTE: Do not use this cycle on delicate fabrics. * The Anti-Bacterial Cycle is Certified by NSF International (formerly National Sanitation Foundation) to NSF Protocol P154 Sanitization Performance of Residential clothes Dryers.

HIGH For regular to heavy cottons.

MEDIUM For synthetics, blends and items labeled permanent press.

LOW For delicates, synthetics and items labeled Tumble Dry Low.

EXTRA LOW For lingerie and special-care fabrics.

START/PAUSE Press to start a dry cycle. If the dryer is running, press it once and it will pause the dryer. Press it again to resume the dry cycle.

My Cycle (on some models) Set up your favorite combination of settings and save them here for one touch recall. These custom settings can be set while a cycle is in progress.

M Y

C YCLE

S TORE M Y C YCLE

To store a My CyCLE combination of settings: 1. Select your drying cycle. 2. Change DRy TEMP and SENSOR DRy settings to fit your needs. 3. Select any drying OPTIONS you want. 4. Press and hold the My CyCLE button for 3 seconds to store your selection. A beep will sound the button will light up, and the unit will display “My cycle is now programed with the current cycle settings”.

To recall your stored My CyCLE combination: Press the My CyCLE button before drying a load. The light in the center of the button will light up when My CyCLE is selected.

To change your stored My CyCLE combination: Follow Steps 1–4 in “To store a My CyCLE combination of settings.”

Display

GE PFMN440 — Display diagram (page 7)
Fig. 2 · Display

Special Cycle Status OR Dryer Rack OR Timed Dry

“CLEAN LINT FILTER” (message) This message appears periodically. It is only a reminder.

Page 8 of the GE PFMN440 user manual — Washer Communicated Cycles
Page 8 · click to enlarge
Page 8

About the dryer control panel.

Specialty Cycles 1. Turn the CyCLE knob to SPECIALTy CyCLES. A list of cycle options will appear in the display. 2. Using the cursor buttons, select a CATEGORy. 3. Using the cursor buttons, select a CyCLE. Press the BACK button to take you back to the CATEGORIES. 4. Press ENTER to select. 5. Press the START/PAUSE button.

SPECIALTy CyCLES include:

Garment n coats n Hosiery/Bras (use mesh bag) n Jeans n Khakis

Bed and Bath n Blankets (Cotton) n Comforters n Sheets n Towels

Specialty Cycles n Air Fluff n Dryel n Fleece n Fragile Cottons n Performance Fabrics n Pet Bedding n Play Clothes n Rack Dry n Sleeping Bag n Throw Rugs

Washer Communicated Cycles

To turn on communication, press the SETTINGS button on the washer control panel. When “DRYER LINK” appears in the display, press ENTER. Using the arrow keys, select ON; then press ENTER.

The dryer will only communicate with the washer if the dryer is not running a cycle.

If the washer starts a new cycle before the dryer has a chance to communicate with it, the information will be lost.

When the washer cycle is completed, the washer will communicate with the dryer when any button on the control panel is touched or the door is opened.

The washer will display, “TRANSFERRING CYCLE INFORMATION TO THE DRYER” and the dryer will display, “RECEIVING CYCLE INFORMATION TO THE DRYER”.

Page 9 of the GE PFMN440 user manual — Delay Start
Page 9 · click to enlarge
Page 9

About cycle options.

E XTENDED

Extended Tumble

T UMBLE

Minimizes wrinkles by adding approximately 60 minutes of no-heat tumbling after clothes are dry.

Extended Tumble is automatically selected for the SteamRefresh cycle and cannot be deselected. Dryer will beep and display “Garments Ready” when SteamRefresh is complete. The dryer will continue in Extended Tumble until the door is opened.

The light in center of the button will light up when EXTENDED TUMBLE is on.

D AMP A LERT

Damp Alert

Removing clothes and hanging them when they are damp can reduce the need to iron some items.

This option causes the dryer to beep when clothes have dried to a damp level. Remove items that you wish to hang dry. The DAMP ALERTwill only beep when this option is selected.

The light in center of the button will light up when DAMP ALERT is on.

D RUM

Drum Light

L IGHT S ETTINGS

Press this button to turn on the light in the dryer.

The light in center of the button will light up when DRUM LIGHT is on.

Press the button again to turn the light off.

This only controls the light when the door is shut. NOTE: The light will turn off by itself after one minute when the door is shut.

When the door is opened, the light comes on automatically.

e

e-Dry

DRY

Reduces the total energy consumption of specific dryer cycles by adjusting certain heat settings.

This cycle can be used with DELICATES, ACTIVE WEAR, EASy CARE, NORMAL/MIXED LOADS and COTTONS.

Delay Start

Use to delay the start of your dryer.

1. Choose your dry cycle and any options.

in DELAy, the countdown time will not restart unless the door is closed and START/PAUSE button has been pressed again.

2. Press DELAy START . You can change the delay time in 1/2-hour increments, using the ▲ or ▼ arrow pads.

n You can delay the start of a dry cycle up to 24

3. Press the START/PAUSE button to start the countdown.

hours.

The light in center of the button will light up when DELAy START is on.

The countdown time will be shown in the ESTIMATED TIME REMAININGdisplay.

Page 10 of the GE PFMN440 user manual — Drum Lamp
Page 10 · click to enlarge
Page 10

About cycle options.

L OCK

Lock

You can lock the controls to prevent any selections from being made. Or you can lock the controls after you have started a cycle.

To lock the dryer, press the LOCK button. To unlock the dryer, press and hold the LOCK button for 3 seconds.

children cannot accidentally start the dryer by touching pads with this option selected.

The light in center of the LOCK button will light up when the controls are locked.

Push to Lock Control Hold 3 Secs to Unlock

Even though the controls are locked, the POWER button is still active in case you have to turn the unit off.

D RUM

Settings

L IGHT S ETTINGS

Under the SETTINGS option, you can adjust the volume or the brightness of the display.

DISPLAy BRIGHTNESS can be set from HIGH, MED or LOW.

After you have made your selection, press ENTER.

VOLUME

n End of Cycle (signal) volume can be set from

HIGH, MED, LOW or OFF.

n Control Sounds volume can be set from

Press & hold for 3 seconds for secondary options

HIGH, MED, LOW or OFF.

About dryer features.

Drum Lamp

Before replacing the light bulb, be sure to unplug the dryer power cord or disconnect the dryer at the household distribution panel by removing the fuse or switching off the circuit breaker. Reach above dryer opening from inside the drum. Remove the bulb and replace with the same size bulb.

Page 11 of the GE PFMN440 user manual — Reverse Tumble ™
Page 11 · click to enlarge
Page 11

About dryer features (cont.). GEAppliances.com

Built-In Rack Dry System

A handy drying rack may be used for drying items such as tennis shoes. Place items flat on the drying rack and block such items as wool sweaters and delicate fabrics. Dry with low heat.

To install the Built-In Rack Dry System 1. Make sure the drum of the dryer is oriented so the rack drying system is on the left side of the dryer. 2. Pull the drying rack screen out from the left side and engage the handle “posts” in the opposite baffle slots. 3. Place the garment on the rack and close the door. 4. Press the DRyER RACK button. 5. Select desired time. 6. Press the START/PAUSE button.

Engage the handle posts

n Make sure to detach the drying rack at the end of the cycle and fully retract the

screen back into the baffle.

GE PFMN440 — Built-In Rack Dry System diagram (page 11)
Fig. 3 · Built-In Rack Dry System
1. Make sure the drum of the dryer is oriented so the hook is on the top center of the dryer. 2. Using your finger, pull the hook out of the baffle. 3. Hang the garment on a hanger, hang the hanger on the hook and close the door. 4. Press the DRyER RACK button. 5. Select the desired time. 6. Press the START/PAUSE button.

Reverse Tumble ™

All Profile front-load matching dryers are equipped with the Reverse Tumble™feature, as part of the Duo Dry Plus system™. By reversing the direction of drum rotation during the drying cycle, your dryer will tangle the clothes load less, dry more evenly and improve drying times. Typical loads such as bed and bath mixed loads, where sheets, towels and pillow cases are laundered together, benefit from this capability. When the dryer reverses direction, there will be a slight pause and sound change. This is normal. All dryer cycles utilize this feature, except when the rack dry option is selected, in which case the drum does not tumble.

Page 12 of the GE PFMN440 user manual — Heat setting
Page 12 · click to enlarge
Page 12

Using the dryer.

Always follow fabric manufacturer’s care label when laundering.

Sorting and Loading Hints As a general rule, if clothes are sorted properly for the washer, they are sorted properly for the dryer. Try also to sort items according to size. For example, do not dry a sheet with socks or other small items. Do not add fabric softener sheets once the load has become warm. They may cause fabric softener stains. Bounce® Fabric Conditioner Dryer Sheets have

been approved for use in this dryer when used in accordance with the manufacturer’s instructions. See below for lint filter cleaning instructions. Do not overload. This wastes energy and causes wrinkling. Do not dry the following items: fiberglass items, woolens, rubber-coated items, plastics, items with plastic trim and foam-filled items.

Fabric Care Labels

Below are fabric care label “symbols” that affect the clothing you will be laundering.

Dry Labels

Tumble dry

Do not dry (used with do not wash)

Dry Normal Permanent Press/

Do not tumble dry

Heat setting

High Medium Low No heat/air

Line dry/ hang to dry

Drip dry Dry flat In the shade

Care and Cleaning of the Dryer Dryer Interior and Duct: The interior of the appliance and exhaust duct should be cleaned once a year by qualified service personnel. The Exterior: Wipe or dust any spills or washing compounds with a damp cloth. Dryer control panel and finishes may be damaged by some laundry pretreatment soil and stain remover products. Apply these products away from the dryer. The fabric may then be washed and dried normally. Damage to your dryer caused by these products is not covered by your warranty. Do not touch the surface or the display with sharp objects. The Lint Filter: Clean the lint filter before each use. Remove by pulling straight up. Run your fingers across the filter. A waxy buildup may form on the lint filter from using dryer-added fabric softener sheets. To remove this buildup, wash the lint screen in warm, soapy water. Dry thoroughly and

replace. Do not operate the dryer without the lint filter in place. Vacuum the lint from the dryer lint filter if you notice a change in dryer performance. Stainless Steel: To clean stainless steel surfaces, use a damp cloth with a mild, nonabrasive cleaner suitable for stainless steel surfaces. Remove the cleaner residue, and then dry with a clean cloth. The stainless steel used to make the dryer drum provides the highest reliability available in a GE dryer. If the dryer drum should be scratched or dented during normal use, the drum will not rust or corrode. These surface blemishes will not affect the function or durability of the drum. The Exhaust Hood: Check with a mirror that the inside flaps of the hood move freely when operating. Make sure that there is no wildlife (birds, insects, etc.) nesting inside the duct or hood.

Gentle/ delicate · wrinkle resistant · Special instructions

Page 13 of the GE PFMN440 user manual — DRY
Page 13 · click to enlarge
Page 13

SMART APPLIANCE (on some models) GEAppliances.com

Models PFDS450, PFDS455, PFDN440, PFDN445 are compatible with the GE Smart Appliance Module (SAM) which can be purchased separately. Contact your local utility or visit www.GEAppliances.com/smart-appliances to see if your area is using Demand Response (DR) technology. Installation The preferred location for the module installation is on top of the clothes dryer. Details on how to connect the cables to the module are in the instructions that come with the module.

Settings Menu Press SETTINGS; then select Energy Management.

Delay EP Override If you are starting a cycle in a Critical or High utility rate, this option allows the unit to automatically run on an EP Cycle. This setting will operate with less energy than normal cycles. Default setting is YES.

GE PFMN440 — SMART APPLIANCE (on some models) GEAppliances.com diagram (page 13)
Fig. 4 · SMART APPLIANCE (on some models) GEAppliances.com

Wait 5 minutes; then press the Settings button. Scroll and look for the energy management screen as seen below.

Auto-Extend Delays If a timed delay is selected, this option allows for the scheduled start to extend if the utility rate is Critical or High at the scheduled start. The default setting will automatically extend these cycles.

This screen means the module is attached correctly and you can begin to use your Smart Appliance following the instructions below. If the Energy Management Screen is not available, refer to the SAM module troubleshooting guide. Quick Guide There are 4 power levels available: Critical, High, Medium and Low. On the Medium and Low levels, the unit runs as normal. The following steps show how the unit reacts during startup at Critical and High power levels. Option 1 (Delay EP) During startups at Critical and High levels, the unit will delay starting until the level becomes Medium or Low. Press the START/PAUSE button.

Critical Rate Option This option allows your smart appliance to respond to Critical Rate information by automatically engaging the Critical Response Mode. The Critical Response Mode is designed to maximize energy savings when a cycle is run during a Critical Rate period. The default setting is YES. Setting this option to NO will disable the Critical Response Mode.

Timed Dry EP Option If the unit is running in Timed Dry Mode and the utility rate switches to Critical or High, the unit will conserve energy by decreasing heat if YES (default) is selected. If NO is selected, the unit will operate normally.

Option 2 (Override Delay EP) To start the unit when Delay EP is shown, press the DELAy STARTbutton to turn the delay off. Then press START/PAUSEto begin the cycle. During a Critical Rate period, the Critical Response Mode** will also be activated to maximize energy savings. EP will be displayed.

DRY

D ELAY

D RYER

R ACK

B ACK

B ACK

ENTER

Option 3 (Override "e" DRy) After overriding the delay function, pressing the “e”DRy button will disable the “e”DRysetting. Pressing the START/PAUSEkey will begin the selected cycle. During a Critical Rate period, the Critical Response Mode** will be activated to maximize energy savings. EP will be displayed. **Note: The Critical Response Mode can be disabled at any time by pressing and holding the “e”DRyButton for 3 seconds. EP will be removed from the display

In order for the Smart Appliance features on the appliance to work, additional equipment is required to be installed to interface with the local utility. Such equipment may be sold separately and/or is available through your utility as part of the pilot test program. Check with your utility company to see if a pilot test program is available in your area and for full details.

PLEASE NOTE: If you move to an area where the program is not available, the demand response features cannot be activated and utilized on the appliance. The appliance will function as normal after the demand response equipment has been deactivated or disconnected.

START e

Page 14 of the GE PFMN440 user manual — CALIFORNIA SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT
Page 14 · click to enlarge
Page 14

Installation Dryer Instructions

PFDS450 / PFDS455 /PFDN440 / PFDN445 / PFMS450 / PFMS455 / PFMN440 / PFMN445

Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at: GEAppliances.com In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca

BEFORE YOU BEGIN

FOR YOUR SAFETY:

WARNING – Risk of Fire

Read these instructions completely and carefully.

  • IMPORTANT – Save these instructions for local electrical inspector’s use.
  • To reduce the risk of severe injury or death, follow all installation instructions.
  • Clothes dryer installation must be performed by a qualified installer.
  • Install the clothes dryer according to these instructions and in accordance with local codes.
  • This dryer must be exhausted to the outdoors.
  • Use only rigid metal 4 ″ diameter ductwork inside the dryer cabinet and use only UL approved transition ducting between the dryer and the home duct.
  • DO NOT install a clothes dryer with flexible plastic ducting materials. If flexible metal (semi-rigid or foil-type) duct is installed, it must be UL-listed and installed in accordance with the instructions found in “Connecting the Dryer to House Vent” on page 26 of this manual. Flexible ducting materials are known to collapse, be easily crushed and trap lint. These conditions will obstruct dryer airflow and increase the risk of fire.
  • Do not install or store this appliance in any location where it could be exposed to water and/or weather.
  • Save these instructions. (Installers: Be sure to leave these instructions with the customer.)
  • IMPORTANT – Observe all governing codes and ordinances.
  • Install the clothes dryer according to the manufacturer’s instructions and local codes.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Clothes dryer installation must be performed by a qualified installer.
  • This dryer must be exhausted to the outdoors.
  • Before the old dryer is removed from service or discarded, remove the dryer door.
  • Service information and the wiring diagram are located in the control console.
  • Do not allow children on or in the appliance. Close supervision of children is necessary when the appliance is used near children.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the Warranty .
  • Install the dryer where the temperature is above 50°F for satisfactory operation of the dryer control system.
  • Remove and discard existing plastic or metal foil duct and replace with UL-listed duct.

CALIFORNIA SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

FOR GAS MODELS ONLY:

This act requires the governor of California to publish a list of substances known to the state to cause cancer, birth defects or other reproductive harm and requires businesses to warn customers of potential exposure to such substances. Gas appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde and soot, caused primarily by the incomplete combustion of natural gas or LP fuels. Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances can be minimized further by properly venting the dryer to the outdoors.

  • NOTE: Installation and service of this dryer must be performed by a qualified installer, service agency or the gas supplier. In the Commonwealth of Massachusetts:
  • This product must be installed by a licensed plumber or gas fitter.
  • When using ball-type gas shut-off valves, they shall be T-handle-type.
  • A flexible gas connector, when used, must not exceed 3 feet.
Page 15 of the GE PFMN440 user manual — 49-90396 ENv11.pdf
Page 15 · click to enlarge
Page 15
GE PFMN440 — 49-90396 ENv11.pdf diagram (page 15)
Fig. 5 · 49-90396 ENv11.pdf

Tilt the dryer sideways and remove the foam shipping pads by pulling at the sides and breaking them away from the dryer legs. Be sure to remove all of the foam pieces around the legs.

Remove the bag containing the literature and serial cable.

GE PFMN440 — 49-90396 ENv11.pdf diagram (page 15)
Fig. 6 · 49-90396 ENv11.pdf

Minimum clearance to combustible surfaces and for air openings are:

Consideration must be given to provide adequate clearance for proper operation and service.

Page 16 of the GE PFMN440 user manual — RESIDENTIAL GARAGE INSTALLATION
Page 16 · click to enlarge
Page 16
  • REQUIREMENTS FOR ALCOVE OR CLOSET INSTALLATION
  • Your dryer is approved for installation in an alcove or closet, as stated on a label on the dryer back.
  • The dryer MUST be vented to the outdoors. See the EXHAUSTING THE DRYER section.
  • Minimum clearance between dryer cabinet and adjacent walls or other surfaces is:

BATHROOM OR BEDROOM INSTALLATION

  • The dryer MUST be vented to the outdoors. See EXHAUSTING THE DRYER.
  • The installation must conform with local codes or, in the absence of local codes, with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70 (for electric dryers) or NATIONAL FUEL GAS CODE, ANSI Z223 (for gas dryers).
  • 0 ″ either side 3 ″ front and rear
  • Minimum vertical space from floor to overhead shelves, cabinets, ceilings, etc., is 52 ″ .
  • Closet doors must be louvered or otherwise ventilated and have at least 60 square inches of open area equally distributed. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 square inches of open area equally distributed.
  • The closet should be vented to the outdoors to prevent gas pocketing in case of gas in the supply line.
  • No other fuel-burning appliance shall be installed in the same closet with the dryer (gas models only). NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF THE DRYER, MINIMUM CLEARANCE FROM THE WALL IS 5.5 INCHES.

MOBILE OR MANUFACTURED HOME INSTALLATION

  • The installation must conform to the MANUFACTURED HOME CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART 32–80 or, when such standard is not applicable, with AMERICAN NATIONAL STANDARD FOR MOBILE HOME, NO. 501B.
  • The dryer MUST be vented to the outdoors with the termination securely fastened to the mobile home structure. (See EXHAUSTING THE DRYER.)
  • The vent MUST NOT be terminated beneath a mobile or manufactured home.
  • The vent duct material MUST BE METAL.
  • FOR GAS MODELS ONLY: KIT 14-D346-33 MUST be used to attach the dryer securely to the structure.
  • FOR GAS MODELS ONLY: The vent MUST NOT be connected to any other duct, vent or chimney.
  • Do not use sheet metal screws or other refastening devices which extend into the interior of the exhaust vent.
  • Provide an opening with a free area of at least 25 sq. in. for introduction of outside air into the dryer room.

RESIDENTIAL GARAGE INSTALLATION

  • Dryers installed in residential garages must be elevated 18 inches (46cm) above the floor.
Page 17 of the GE PFMN440 user manual — WATER SUPPLY REQUIREMENTS
Page 17 · click to enlarge
Page 17

CONNECTING INLET HOSES

CONNECTING INLET HOSES

CONNECTING INLET HOSES (cont.)

To produce steam, the dryer must connect to the cold water supply. Since the washer must also connect to the cold water, a “Y” connector is inserted to allow both inlet hoses to make that connection at the same time.

1. Turn the cold water faucet off. Remove the washer inlet hose from the washer fill valve connector (cold). 2. Ensure the rubber flat washer is in place and screw the female coupling of the short hose onto the washer fill valve connector. Tighten by hand until firmly seated. 3. Attach the female end of the ‘’Y’’ connector to the male coupling of the short hose. Ensure the rubber flat washer is in place. Tighten by hand until firmly seated.
7. Using pliers, tighten all the couplings with an additional two–thirds turn.
8. Turn the water faucet on.
9. Check for leaks around the ‘’Y’’ connector, faucet and hose couplings.

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets MUST be installed within 42 in. (107 cm) of your washer’s water inlet. The faucets MUST be 3/4 in. (1.9 cm) garden hose-type so inlet hoses can be connected. Water pressure MUST be between 10 and 120 pounds per square inch. Your water department can advise you of your water pressure.

4. Insert the filter screen in the coupling of the washer ’s inlet hose. If a rubber flat washer is already in place remove it before installing the filter screen. Attach this coupling to one male end of the ‘’Y’’ connector. Tighten by hand until firmly seated. 5. Ensure the rubber flat washer is in place and attach the dryer ’s long inlet hose to the other male end of the ‘’Y’’ connector. Tighten by hand until firmly seated.
6. Ensure the rubber flat washer is in place and attach the other end of the dryer ’s long inlet hose to the fill valve connector at the bottom of the dryer back panel. Tighten by hand until firmly seated.
Page 18 of the GE PFMN440 user manual — 49-90396 ENv11.pdf
Page 18 · click to enlarge
Page 18
GE PFMN440 — 49-90396 ENv11.pdf diagram (page 18)
Fig. 7 · 49-90396 ENv11.pdf

Before beginning the installation, turn off the circuit breaker(s) or remove the dryer’s circuit fuse(s) at the electrical box. Be sure the dryer cord is unplugged from the wall.

Turn the dryer’s gas shut-off valve in the supply line to the OFF position.

Disconnect and discard old flexible gas connector and ducting material.

Page 19 of the GE PFMN440 user manual — DRYER GAS SUPPLY CONNECTION
Page 19 · click to enlarge
Page 19

GAS REQUIREMENTS

GAS SUPPLY

WARNING

  • A 1/8 ″ National Pipe Taper thread plugged tapping, accessible for test gauge connection, must be installed immediately upstream of the gas supply connection to the dryer. Contact your local gas utility should you have questions on the installation of the plugged tapping.
  • Supply line is to be 1/2 ″ rigid pipe and equipped with an accessible shutoff within 6 feet of, and in the same room with, the dryer.
  • Use pipe thread compound appropriate for natural or LP gas or use Teflon ® tape.
  • Connect flexible metal connector to dryer and gas supply.
  • Installation must conform to local codes and ordinances, or in their absence, the NATIONAL FUEL GAS CODE, ANSI Z223.
  • This gas dryer is equipped with a Valve and Burner Assembly for use only with natural gas. Using conversion kit 14-A048, your local service organization can convert this dryer for use with propane (LP) gas. ALL CONVERSIONS MUST BE MADE BY PROPERLY TRAINED AND QUALIFIED PERSONNEL AND IN ACCORDANCE WITH LOCAL CODES AND ORDINANCE REQUIREMENTS.
  • The dryer must be disconnected from the gas supply piping system during any pressure testing of that system at a test pressure in excess of 0.5 PSI (3.4 KPa).
  • The dryer must be isolated from the gas supply piping system by closing the equipment shut-off valve during any pressure testing of the gas supply piping of test pressure equal to or less than 0.5 PSI (3.4KPa).

IN THE COMMONWEALTH OF MASSACHUSETTS

  • This product must be installed by a licensed plumber or gas fitter.
  • When using ball-type gas shut-off valves, they shall be the T-handle type.
  • A flexible gas connector, when used, must not exceed 3 feet.

DRYER GAS SUPPLY CONNECTION

2 ″ (5.1 cm) ADjUSTING FOR ELEVATION

  • Gas clothes dryers input ratings are based on sea level operation and need not be adjusted for operation at or below 2000 ft. elevation. For operation at elevations above 2000 ft., input ratings should be reduced at a rate of 4 percent for each 1000 ft. above sea level.
  • Installation must conform to local codes and ordinances or, in their absence, the NATIONAL FUEL GAS CODE, ANSI Z223.

3/8″ NPT MALE THREAD GAS SUPPLY NOTE: Add to vertical dimension the distance between cabinet bottom to floor.

25⁄8″ (6.7 cm)

Page 20 of the GE PFMN440 user manual — 3/8 ″ NPT
Page 20 · click to enlarge
Page 20

CONNECTING A GAS DRYER (cont.)

CONNECTING THE DRYER TO THE GAS SUPPLY

CONNECTING THE DRYER TO THE GAS SUPPLY (cont.)

Install a female 3/8″ NPT elbow at the end of the dryer gas inlet. Install a 3/8″ flare union adapter to the female elbow. IMPORTANT: Use a pipe wrench to securely hold on to the end of the dryer gas inlet to prevent twisting the inlet. NOTE: Apply pipe compound or Teflon® tape to the threads of the adapter and dryer gas inlet.

A

D

Install a 1/8″ NPT plugged tapping to the dryer gas line shut-off valve for checking gas inlet pressure.

Install a flare union adapter to the plugged tapping.

New Metal Flexible Gas Line Connector

Apply pipe compound or Teflon® tape to all male threads.

1/8″ NPT Pipe Plug for Checking Gas Inlet Pressure

3/8 ″ NPT

Pipe size at least 1/2″

Attach the flexible metal gas line connector to the adapter. B

Tighten all connections, using two adjustable wrenches. Do not overtighten. E

Apply pipe compound to the adapter and dryer gas inlet.

Tighten the flexible gas line connection, using two adjustable wrenches. C

Open the gas shut-off valve. F

Show 7 more labels / short text on this page
Adapter · Plugged Tapping · Adapter · Elbow · Shut-Off Valve · Items not supplied · Shut-Off Valve
Page 21 of the GE PFMN440 user manual — ELECTRICAL CONNECTION INFORMATION FOR GAS DRYERS
Page 21 · click to enlarge
Page 21

TEST FOR LEAKS

ELECTRICAL REQUIREMENTS FOR GAS DRYERS

This appliance must be supplied with 120V, 60Hz, and connected to a properly grounded branch circuit, protected by a 15- or 20-amp circuit breaker or time-delay fuse.

Check all connections for leaks with soapy solution or equivalent.

Apply a soap solution. The leak test solution must not contain ammonia, which could cause damage to the brass fittings.

If electrical supply provided does not meet the above specifications, it is recommended that a licensed electrician install an approved outlet.

If leaks are found, close the valve, retighten the joint and repeat the soap test.

Ensure proper ground exists before use.

ELECTRICAL CONNECTION INFORMATION FOR GAS DRYERS

If local codes permit, an external ground wire (not provided), which meets local codes, may be added by attaching to the green ground screw on the rear of the dryer, and to an alternate established ground.

Ensure proper ground exists before use.

  • Do not use an extension cord or an adapter plug with this appliance.
  • The dryer must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, in accordance with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70.

Open Gas Valve · Ground Screw

Page 22 of the GE PFMN440 user manual — ELECTRICAL CONNECTION INFORMATION FOR ELECTRIC DRYERS
Page 22 · click to enlarge
Page 22

CONNECTING AN ELECTRIC DRYER (skip for gas dryers)

TOOLS YOU WILL NEED

FOR YOUR SAFETY:

WARNING

Before making the electrical connection, turn off the circuit breaker(s) or remove the dryer’s circuit fuse(s) at the electrical box. Be sure the dryer cord is unplugged from the wall. NEVER LEAVE THE ACCESS COVER OFF THE TERMINAL BLOCK.

MATERIALS YOU WILL NEED

r4″ dia. metal elbow

ELECTRICAL CONNECTION INFORMATION FOR ELECTRIC DRYERS

r3/4″ strain relief

r4″ duct clamps (2) or

4″ spring clamps (2)

  • Do not use an extension cord or an adapter plug with this appliance.
  • The dryer must be electrically grounded in accordance with local codes and ordinances or, in the absence of local codes, in accordance with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70.

rDryer power cord kit

(not provided with dryer) UL rated 120/240V, 30A with 3 or 4 prongs. Identify the plug type as per the house receptacle before purchasing line cord.

r4″ dia. metal duct

r4″ dia., UL-listed flexible

metal duct (if needed)

Show 10 more labels / short text on this page
rPhillips screwdriver · rSlip-joint pliers · rLevel · rFlat-blade screwdriver · rGloves · (UL recognized) · rExhaust hood · rDuct tape · rSafety glasses · (recommended)
Page 23 of the GE PFMN440 user manual — CONNECTING DRYER USING 4-WIRE CONNECTION (MUST BE USED FOR MOBILE HOME INSTALLATION)
Page 23 · click to enlarge
Page 23

ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS

CONNECTING DRYER USING 4-WIRE CONNECTION (MUST BE USED FOR MOBILE HOME INSTALLATION) (cont.)

This dryer must be connected to an individual branch circuit, protected by the required time- delay fuses or circuit breakers. A three- or four- wire, single-phase, 120/240V, 60Hz, 30-amp circuit is required.

1. Turn off the circuit breaker(s) (30 amp) or remove the dryer’s circuit fuse at the electrical box. 2. Be sure the dryer cord is unplugged from the wall receptacle. 3. Remove the power cord cover located at the lower back. 4. Remove and discard ground strap. Keep the green ground screw for Step 7. 5. Install 3/4 in. UL-recognized strain relief to power cord entry hole. Bring power cord through strain relief. 6. Connect power cord as follows: A. Connect the 2 hot lines to the outer screws

If the electric supply does not meet the above specifications, then call a licensed electrician.

GROUNDING INSTRUCTIONS

This dryer must be connected to a grounded metal, permanent wiring system, or an equipment- grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal on the appliance.

of the terminal block (marked L1 and L2). B. Connect the neutral (white) line to the center

of the terminal block (marked N). 7. Attach ground wire of power cord with the green ground screw (hole above strain relief bracket). Tighten all terminal block screws (3) completely. 8. Properly secure power cord to strain relief. 9. Reinstall the cover.

CONNECTING DRYER USING 4-WIRE CONNECTION (MUST BE USED FOR MOBILE HOME INSTALLATION)

Remove ground strap and discard. Keep green ground screw

Relocate green ground screw here

Hot Wire Neutral (white)

3/4″ UL Recognized Strain Relief

Cover 4 #10 AWG minimum copper conductors or 120/240V 30A power supply cord kit marked for use with dryers and provided with closed loop or spade terminals with upturned ends (not supplied)

Show 4 more labels / short text on this page
Hot Wire · Green Wire · Strain Relief Bracket · Screws (3)
Page 24 of the GE PFMN440 user manual — CONNECTING DRYER USING 3-WIRE CONNECTION
Page 24 · click to enlarge
Page 24

CONNECTING AN ELECTRIC DRYER (cont.)

CONNECTING DRYER USING 3-WIRE CONNECTION

If required, by local code, install external ground (not provided) to grounded metal, cold water pipe, or other established ground determined by a qualified electrician.

Hot Wire Neutral (white)

3/4″ UL Recognized Strain Relief

Cover 3 #10 AWG minimum copper conductors or 120/240V 30A power supply cord kit marked for use with dryers and provided with closed loop or spade terminals with upturned ends (not supplied)

1. Turn off the circuit breaker(s) (30 amp) or remove the dryer’s circuit fuse at the electrical box. 2. Be sure the dryer cord is unplugged from the wall receptacle. 3. Remove the power cord cover located at the lower back. 4. Install 3/4-in. UL-recognized strain relief to power cord entry hole. Bring power cord through strain relief. 5. Connect power cord as follows: A. Connect the 2 hot lines to the outer screws

of the terminal block (marked L1 and L2). B. Connect the neutral (white) line to the center

of the terminal block (marked N). 6. Be sure ground strap is connected to neutral (center) terminal of block and to green ground screw on cabinet rear. Tighten all terminal block screws (3) completely. 7. Properly secure power cord to strain relief. 8. Reinstall the cover.

Show 5 more labels / short text on this page
Green Ground Screw · Ground Strap · Strain Relief Bracket · Hot Wire · Screws (3)
Page 25 of the GE PFMN440 user manual — TOOLS AND MATERIALS YOU WILL NEED TO INSTALL EXHAUST DUCT
Page 25 · click to enlarge
Page 25

EXHAUSTING THE DRYER

  • WARNING – To reduce the risk of fire or personal injury:
  • This clothes dryer must be exhausted to the outdoors.
  • Use only 4 ″ rigid metal ducting for the home exhaust duct.
  • Use only 4 ″ rigid metal or UL-listed flexible metal (semi-rigid or foil-type) duct to connect the dryer to the home exhaust duct. It must be installed in accordance with the instructions found in “Connecting the Dryer to House Vent” on page 26 of this manual.
  • Do not terminate exhaust in a chimney, a wall, a ceiling, gas vent, crawl space, attic, under an enclosed floor, or in any other concealed space of a building.
  • Never terminate the exhaust into a common duct with a kitchen exhaust system. A combination of grease and lint creates a potential fire hazard.
  • Do not use duct longer than specified in the exhaust length table. Longer ducts can accumulate lint, creating a potential fire hazard.
  • Never install a screen in or over the exhaust duct. This will cause lint to accumulate, creating a potential fire hazard.
  • Do not assemble ductwork with any fasteners that extend into the duct. These fasteners can accumulate lint, creating a potential fire hazard.
  • Do not obstruct incoming or exhausted air.
  • Provide an access for inspection and cleaning of the exhaust system, especially at turns and joints. Exhaust system shall be inspected and cleaned at least once a year.
  • This dryer comes ready for rear exhausting. If space is limited, use the instructions on pages 29–31 to exhaust directly from the sides or bottom of the cabinet.

EXHAUST SYSTEM CHECKLIST

  • HOOD OR WALL CAP
  • Terminate in a manner to prevent back drafts or entry of birds or other wildlife.
  • Termination should present minimal resistance to the exhaust airflow and should require little or no maintenance to prevent clogging.
  • Never install a screen in or over the exhaust duct.
  • Wall caps must be installed at least 12 ″ above ground level or any other obstruction with the opening pointed down.

SEPARATION OF TURNS • For best performance, separate all turns by at least 4 ft. of straight duct, including distance between last turn and dampened wall cap.

  • SEALING OF jOINTS
  • All joints should be tight to avoid leaks. The male end of each section of duct must point away from the dryer.
  • Do not assemble the ductwork with fasteners that extend into the duct. They will serve as a collection point for lint.
  • Duct joints should be made airand moisture-tight by wrapping the overlapped joints with duct tape or aluminum tape.
  • Horizontal runs should slope down towards the outdoors 1/4 ″ per foot.

INSULATION • Ductwork that runs through an unheated area or is near air conditioning should be insulated to reduce condensation and lint buildup.

TOOLS AND MATERIALS YOU WILL NEED TO INSTALL EXHAUST DUCT

rDrill with 1/8″ drill bit

rDuct tape or duct clamp

rRigid or UL-listed flexible

metal 4″ (10.2 cm) duct

Show 4 more labels / short text on this page
rPhillips-head screwdriver · (for bottom venting) · rHacksaw · rVent hood
Page 26 of the GE PFMN440 user manual — DO NOT:
Page 26 · click to enlarge
Page 26

EXHAUSTING THE DRYER (cont.)

CONNECTING THE DRYER TO HOUSE VENT

FOR TRANSITION VENTING (DRYER TO WALL), DO:

  • RIGID METAL TRANSITION DUCT
  • For best drying performance, a rigid metal transition duct is recommended.
  • Rigid metal transition ducts reduce the risk of crushing and kinking.
  • DO cut duct as short as possible and install straight into wall.
  • UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT
  • If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit WX08X10077).
  • Never install flexible metal duct in walls, ceilings, floors or other enclosed spaces.
  • Total length of flexible metal duct should not exceed 8 feet (2.4 m).
  • For many applications, installing elbows at both the dryer and the wall is highly recommended (see illustrations at right). Elbows allow the dryer to sit close to the wall without kinking and/or crushing the transition duct, maximizing drying performance.
  • Avoid resting the duct on sharp objects.
  • DO use elbows when turns are necessary.

DO NOT:

  • UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT
  • In special installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4 ″ diameter can be maintained throughout the entire length of the transition duct.
  • In Canada and the United States, only the flexible metal (foil-type) ducts that comply with the “Outline for Clothes Dryer Transition Duct Subject 2158A” shall be used.
  • Never install flexible metal duct in walls, ceilings, floors or other enclosed spaces.
  • Total length of flexible metal duct should not exceed 8 feet (2.4 m).
  • Avoid resting the duct on sharp objects.
  • For best drying performance: 1. Slide one end of the duct over the clothes dryer outlet pipe. 2. Secure the duct with a clamp. 3. With the dryer in its permanent position, extend the duct to its full length. Allow 2 ″ of duct to overlap the exhaust pipe. Cut off and remove excess duct. Keep the duct as straight as possible for maximum airflow. 4. Secure the duct to the exhaust pipe with the other clamp.
  • DO NOT bend or collapse ducting. Use elbows if turns are necessary.
  • DO NOT use excessive exhaust length. Cut duct as short as possible.
  • DO NOT crush duct against the wall.
  • DO NOT set dryer on duct.

Elbows

Page 27 of the GE PFMN440 user manual — INSULATION
Page 27 · click to enlarge
Page 27

EXHAUST SYSTEM CHECKLIST

HOOD OR WALL CAP

  • Terminate in a manner to prevent back drafts or entry of birds or other wildlife.
  • Termination should present minimal resistance to the exhaust airflow and should require little or no maintenance to prevent clogging.
  • Never install a screen in or over the exhaust duct. This could cause lint buildup.
  • Wall caps must be installed at least 12 ″ above ground level or any other obstruction with the opening pointed down.

Using exhaust longer than specified length will:

  • Increase the drying times and the energy cost.
  • Reduce the dryer life.
  • Accumulate lint, creating a potential fire hazard. The correct exhaust installation is YOUR RESPONSIBILITY.

Problems due to incorrect installation are not covered by the warranty.

SEPARATION OF TURNS

The MAXIMUM ALLOWABLE length of the exhaust system depends upon the type of duct, number of turns, the type of exhaust hood (wall cap) and all conditions noted below.

For best performance, separate all turns by at least 4 ft. of straight duct, including the distance between the last turn and the exhaust hood.

TURNS OTHER THAN 90º

EXHAUST LENGTH

  • One turn of 45º or less may be ignored.
  • Two 45º turns should be treated as one 90º turn.
  • Each turn over 45º should be treated as one 90º turn.

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended Use only for short-

4 ″ DIA 4 ″ DIA

SEALING OF jOINTS

  • All joints should be tight to avoid leaks. The male end of each section of duct must point away from the dryer.
  • Do not assemble the ductwork with fasteners that extend into the duct. They will serve as a collection point for lint.
  • Duct joints can be made airand moisture-tight by wrapping the overlapped joints with duct tape.
  • Horizontal runs should slope down toward the outdoors 1/2 ″ per foot.

4 ″ DIA

4″ 21⁄2″

No. of 90º Rigid Rigid Elbows Metal Metal

0 150 Feet 125 Feet 1 135 Feet 115 Feet 2 125 Feet 105 Feet 3 115 Feet 95 Feet 4 105 Feet 85 Feet 5 95 Feet 75 Feet

INSULATION

Ductwork that runs through an unheated area or is near air conditioning should be insulated to reduce condensation and lint buildup.

run installations

Page 28 of the GE PFMN440 user manual — 49-90396 ENv11.pdf
Page 28 · click to enlarge
Page 28
GE PFMN440 — 49-90396 ENv11.pdf diagram (page 28)
Fig. 8 · 49-90396 ENv11.pdf
  • Remove and discard existing plastic or metal foil duct and replace with UL-listed duct.
  • Remove any lint from the wall exhaust opening.

Using duct elbows will prevent duct kinking and collapsing.

Check that exhaust hood damper opens and closes freely.

We recommend that you install your dryer before installing your washer. This will permit direct access for easier exhaust connection.

Slide the end of the exhaust duct on the back of the dryer and secure with duct tape or a hose clamp.

  • For straight-line installation, connect the dryer exhaust to the wall, using duct tape.
Page 29 of the GE PFMN440 user manual — TAB LOCATION
Page 29 · click to enlarge
Page 29

SIDE VENTING:

ADDING A NEW DUCT

Dryer Exhaust to right of cabinet for Electric models only. Dryer Exhaust to left of cabinet for Gas and Electric models.

Reconnect the cut portion (A) of the duct to the blower housing. Make sure that the shortened duct is aligned with the tab in the base. Use the screw saved previously to secure the duct in place through the tab on the appliance base.

Remove screw and save

ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT OR RIGHT SIDE OF CABINET

Remove desired knockout (one only)

Detach and remove the bottom, right or left side knockout as desired. Remove the screw inside the dryer exhaust duct and save. Pull the duct out of the dryer.

  • Insert the 4 ″ elbow through the rear opening and connect the elbow to the dryer internal duct.

A

13 1⁄2″

  • Insert the 4 ″ duct through the side opening and connect it to the elbow.

Cut the duct as shown and keep portion A.

TAB LOCATION

Bend tab up 45°

Through the rear opening, locate the tab in the middle of the appliance base. Lift the tab to about 45°, using a flat-blade screwdriver.

Show 10 more labels / short text on this page
Fixing hole · Portion “A” · Left side exhaust · Right · Internal duct · Left Bottom · Rear opening · Fixing hole · Side opening · Not for gas
Page 30 of the GE PFMN440 user manual — WARNING – NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE. (Kit WE1M454)
Page 30 · click to enlarge
Page 30

EXHAUSTING THE DRYER (cont.)

SIDE VENTING (cont.)

BOTTOM VENTING:

ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT OR RIGHT SIDE OF CABINET (cont.)

Dryer Exhaust to the bottom of cabinet for Gas and Electric models.

  • Apply duct tape as shown on the joint between the dryer internal duct and the elbow, and also the joint between the elbow and the side duct.

Duct tape WARNING – BEFORE PERFORMING THIS EXHAUST INSTALLATION, BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY. PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET. BE SURE TO WEAR GLOVES.

Remove screw and save

ADDING COVER PLATE TO REAR OF CABINET (SIDE EXHAUST)

Remove desired knockout (one only)

Remove the screw inside the dryer exhaust duct and save. Pull the duct out of the dryer. Detach and remove the bottom knockout.

A

Connect standard metal elbows and ducts to complete the exhaust system. Cover back opening with a plate (Kit WE1M454) available from your local service provider. Place dryer in final location.

13 1⁄4″

Cut the duct as shown and keep portion A.

WARNING – NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE. (Kit WE1M454)

Bottom · Fixing hole · Plate (Kit WE1M454)

Page 31 of the GE PFMN440 user manual — WARNING – NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE. (Kit WE1M454)
Page 31 · click to enlarge
Page 31

BOTTOM VENTING (cont.)

  • While still holding down the pipe and elbow from the rear opening, screw the pipes in place with the previously saved screw.

ADDING A NEW DUCT

  • Reconnect the cut portion A of the duct to the blower housing.
  • Apply duct tape as shown on the joint between the dryer internal duct and the elbow.
  • Tape the elbow in a 90-degree position to prevent rotation.
  • Insert the elbow through the rear hole and connect it to portion A. Rotate the elbow through the bottom opening.

Dryer Exhaust to the bottom of cabinet for Gas and Electric models.

ADDING COVER PLATE TO REAR OF CABINET (BOTTOM EXHAUST)

  • While holding down the pipe and elbow, using your hand through the rear opening, drill a 1/8 ″ hole through the bottom tab hole and the pipe as shown in the illustration.

Connect standard metal elbows and ducts to complete the exhaust system. Cover back opening with a plate (Kit WE1M454) available from your local service provider. Place dryer in final location.

WARNING – NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE. (Kit WE1M454)

Show 7 more labels / short text on this page
Portion “A” · Fixing hole · Duct tape · Rear hole · Bottom opening · Bottom view · Plate (Kit WE1M454)
Page 32 of the GE PFMN440 user manual — PLUG DRYER IN
Page 32 · click to enlarge
Page 32

FINAL SETUP

LEVEL THE DRYER

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Stand the dryer upright near the final location and adjust the four leveling legs at the corners to ensure that the dryer is level from side to side and front to rear.

DRYER STARTUP

Press the POWER button.

ATTACH SERIAL CABLE

Attach the serial cable for washer and dryer connection to the serial port on the back of the dryer.

Attach the other end of the cable to the washer before pushing the washer into its final position.

SERVICING

For replacement parts and other information, refer to the back cover for servicing phone numbers.

PLUG DRYER IN

Ensure proper ground exists before use.

Lower Raise · Serial Port · Rear of Dryer

Page 33 of the GE PFMN440 user manual — 49-90396 ENv11.pdf
Page 33 · click to enlarge
Page 33
GE PFMN440 — 49-90396 ENv11.pdf diagram (page 33)
Fig. 9 · 49-90396 ENv11.pdf
  • Read the instructions all the way through before starting.
  • Provide a non-scratching work surface for the doors.
  • Set screws down by their related parts to avoid using them in the wrong places.
  • Normal completion time to reverse the door swing is 30–60 minutes.

These instructions are for changing the hinges from the right side to the left side—if you ever want to switch them back to the right side, follow these same instructions and reverse all references to the left and right.

Page 34 of the GE PFMN440 user manual — 49-90396 ENv11.pdf
Page 34 · click to enlarge
Page 34
GE PFMN440 — 49-90396 ENv11.pdf diagram (page 34)
Fig. 10 · 49-90396 ENv11.pdf
Page 35 of the GE PFMN440 user manual — DISASSEMBLE THE DOOR ASSEMBLY
Page 35 · click to enlarge
Page 35

REVERSING THE DOOR SWING (if desired)

BEFORE YOU START

REMOVE THE DOOR ASSEMBLY (cont.) 1

Unplug the dryer from its electrical outlet.

Close and hold the door, remove the 2 hinge screws (#10 x 0.75″ tapping screws). Pull the door away from the dryer front panel.

2 x B Screws

REMOVE THE DOOR ASSEMBLY

Remove the side hinge cap by opening the dryer door and removing the screw from behind the hinge (#8 x .375″ tapping screw). Then using your hand, pop the hinge cap off the dryer.

DISASSEMBLE THE DOOR ASSEMBLY

1 x C Screw

Lay the door down on a soft, protected, flat surface so that the inner part faces upward (door resting on the handle side).

Remove the 7 screws (#10 x 1.125″ tapping screws) located around the perimeter of the door.

7 x A Screws

Turn the door assembly over and separate the chrome cover from the inner door. Put the inner door aside on a soft, protected flat surface.

Hinge cap

Page 36 of the GE PFMN440 user manual — 49-90396 ENv11.pdf
Page 36 · click to enlarge
Page 36
GE PFMN440 — 49-90396 ENv11.pdf diagram (page 36)
Fig. 11 · 49-90396 ENv11.pdf

A Lay the chrome cover down on a soft,

C Pop the 2 handle caps out toward you and

protected, flat surface so that the inner part faces upward (resting on the handle side). Disassemble the door cap from the chrome cover on the handle side by removing 2 screws (#8 x 0.625″ tapping screws).

reassemble on the opposite side of the chrome cover, where you removed the outer handle.

D Assemble the inner handle onto the opposite side

of the chrome cover, using 4 screws (#8 x 0.625″ tapping screws).

handle by removing 3 screws (#8 x 0.625″ tapping screws). Disassemble the inner handle from the chrome cover by removing 4 screws (#8 x 0.625″ tapping screws).

Page 37 of the GE PFMN440 user manual — REVERSE HINGE AND CAPS
Page 37 · click to enlarge
Page 37

REVERSE DOOR HANDLE AND CAPS (CONT.)

REVERSE HINGE AND CAPS (CONT.)

E Reassemble the outer handle to the inner handle,

using 3 screws (#8 x 0.625″ tapping screws).

3 x D Screws (inner handle)

F Assemble the new right-side door cap

(from reversibility kit), using 2 screws (#8 x 0.625″ tapping screws).

2 x D Screws

  • Turn the inner door on a soft , protected flat surface so that the inner part faces up.
  • Remove the screws, nuts and washers on the opposite side of the hinge, using a quadrex screwdriver.
  • Disassemble the inner door cap from the inner door by removing 2 screws (#8 x 0.75 ″ tapping screws).
  • Disassemble the hinge from the inner door by removing 4 screws (#8-32 x 0.50 ″ machine screws).

Put the chrome cover aside on a soft, protected flat surface.

2 screws, 2 nuts and 2 washers

2 x D Screws

REVERSE HINGE AND CAPS

Remove 4 x E screws

  • Lay the inner door down on a soft , protected flat surface so that the inner part faces down. Disassemble the outer window by opening 2 snaps, lay the outer window on a soft, protected flat surface.
  • Disassemble the inner cover (mask) by opening 2 snaps, lay the inner cover (mask) on a soft, protected flat surface.
Show 9 more labels / short text on this page
Outer window · Snap · Outer handle · Inner cover · (Mask) · Snap · Door cap · Inner door cap · Hinge
Page 38 of the GE PFMN440 user manual — REVERSE HINGE AND CAPS (CONT.)
Page 38 · click to enlarge
Page 38

REVERSING THE DOOR SWING (if desired)

REVERSE HINGE AND CAPS (CONT.)

REASSEMBLE DOOR ASSEMBLY

  • Assemble the hinge to the opposite side of the inner door, using 4 screws (#8-32 x 0.50 ″ machine screws).
  • Assemble the new inner door cap (from reversibility kit) on the opposite side of the hinge, using 2 screws (#8 x 0.75 ″ tapping screws).
  • Install the the screws, nuts and washers on the opposite side of the hinge in the 2 remaining holes.

Turn the inner door over and place on a soft, protected flat surface so that the inner part is facing down. Assemble the chrome cover to the inner door by placing them together. Flip the door assembly over and assemble, using 7 screws (#10 x 1.125″ tapping screws).

Replace 2 x D screws

Replace 4 x E screws

Replace 2 screws, 2 nuts and 2 washers

7 x A Screws

  • Flip the inner door so that the inner part faces down. Assemble the inner cover (mask), be sure the snaps have clamped the inner cover. Assemble the outer window, be sure the 2 snaps have clamped the outer window.

REVERSE FRONT PANEL PLUG BUTTONS AND STRIKE PLATE Remove the 2 plug buttons on the dryer front panel, using a putty knife or other flat tool as shown, and reinstall on the opposite side. Switch the strike bracket and its cover by removing 2 screws (#8 x 0.625″ tapping screws) for each and reinstalling on opposite sides.

Protective piece of tape

Show 9 more labels / short text on this page
Hinge · Inner door cap · Outer window · Snap · 2 Plug buttons · Inner cover · (Mask) · Snap · Strike bracket
Page 39 of the GE PFMN440 user manual — 49-90396 ENv11.pdf
Page 39 · click to enlarge
Page 39
GE PFMN440 — 49-90396 ENv11.pdf diagram (page 39)
Fig. 12 · 49-90396 ENv11.pdf

Place the door back on the dryer front panel, making sure the latch is engaged and the hinge is sitting in the two openings in the dryer front. Assemble the door to the front cabinet, using 2 screws (#10 x 0.75″ tapping screws).

Install the new left-hand hinge cap (from the reversibility kit) onto the hinge, by opening the dryer door and screwing the hinge cap into place.

Page 40 of the GE PFMN440 user manual — FOR YOUR SAFETY:
Page 40 · click to enlarge
Page 40

STACKING THE WASHER AND DRYER (if desired)

BEFORE YOU BEGIN

MINIMUM CLEARANCE OTHER THAN ALCOVE OR CLOSET INSTALLATION

Read these instructions completely and carefully.

  • IMPORTANT – Save these instructions for local electrical inspector’s use.

Minimum clearance to combustible surfaces and for air opening are: 0″ both sides, 1″ front and 3″ rear. Consideration must be given to provide adequate clearance for installation and service.

  • IMPORTANT – Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • REQUIREMENTS FOR ALCOVE OR CLOSET INSTALLATION
  • Your dryer is approved for installation in an alcove or closet, as stated on a label on the dryer back.
  • The dryer MUST be vented to the outdoors. See the EXHAUSTING THE DRYER section.
  • Minimum clearance between dryer cabinet and adjacent walls or other surfaces is:
  • Note to Consumer – Keep these instructions for future reference.
  • Service must be performed by a qualified installer.
  • Proper installation is the responsibility of the installer.
  • 0 ″ either side 3 ″ front and rear
  • Minimum vertical space from floor to overhead shelves, cabinets, ceilings, etc., is 52 ″ .
  • Closet doors must be louvered or otherwise ventilated and have at least 60 square inches of open area equally distributed. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 square inches of open area equally distributed.
  • The closet should be vented to the outdoors to prevent gas pocketing in case of gas in the supply line.
  • No other fuel-burning appliance shall be installed in the same closet with the dryer (gas models only). NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF THE DRYER, MINIMUM CLEARANCE FROM THE WALL IS 5.5 INCHES.

FOR YOUR SAFETY:

WARNING –

  • Electric Shock Hazard. Disconnect power before installing. Failure to do so could result in serious injury or death.
  • Potential Personal Injury. More than two people are recommended to lift the dryer into position because of its weight and size. Failure to do so could result in personal injury or death.
  • Avoid Tipping and Rupture of Utility Services. Dryer must be securely attached to the washer. DO NOT place the washer on top of the dryer. Failure to do so could result in personal injury/death or property damage.
  • Mobile Home or Manufactured Home Installation – Stacking of a gas dryer is not permitted in a mobile home or manufactured home.
Page 41 of the GE PFMN440 user manual — 49-90396 ENv11.pdf
Page 41 · click to enlarge
Page 41
GE PFMN440 — 49-90396 ENv11.pdf diagram (page 41)
Fig. 13 · 49-90396 ENv11.pdf

A. Carefully lay the dryer on its side. Use the

packing material so you don’t scratch the finish on the dryer.

B. Use an open-end wrench or pliers to remove

Locate the 4 rubber pads in the parts package. Remove the adhesive backing and firmly place over on the bracket where you removed the leveling legs.

Flatten the product carton to use as a pad to lay the dryer down on its side. Continue using the carton to protect the finished floor in front of the installation location.

Page 42 of the GE PFMN440 user manual — INSTALL DRYER AND BRACKET ON WASHER
Page 42 · click to enlarge
Page 42

INSTALL BRACKET TO DRYER

FINALIzE THE INSTALLATION

A. Align the holes in the left bracket with the holes

A. Refer to the washer Installation Instructions

in the bottom left corner of the dryer. Use a Phillips screwdriver to install the 2 #12 x 1″ tapping screws.

to complete the washer installation.

B. Refer to the dryer Installation Instructions

to complete the dryer installation.

B. Repeat the above step with the right bracket

C. Carefully slide or walk the stacked washer and

on the bottom right corner of the dryer.

dryer into place. Use felt pads or other sliding device to assist moving and to protect flooring.

C. Set the dryer upright.

INSTALL DRYER AND BRACKET ON WASHER

A. Lift the dryer on top of the washer. Be careful

not to scratch the top of the washer with the brackets. Protect the washer control panel with cardboard or other protection. Be sure to lift the dryer high enough to clear the washer control panel.

B. Align the holes in the bracket with the holes

in the back of the washer. Using a Phillips screwdriver, attach the 2 #8 x 1/2″ tapping screws. Repeat on both sides of the washer.

Place hands here · Place hands here

Page 43 of the GE PFMN440 user manual — TOOLS YOU WILL NEED
Page 43 · click to enlarge
Page 43

INSTALLING THE PEDESTAL (if desired)

INSTALLATION PREPARATION Remove the packaging. The drawer divider is taped at the top of the shipping carton. Remove the divider and set aside for final installation. Flatten the product carton to use as a pad to lay the washer or dryer down on its side. Continue using the carton to protect the finished floor in front of the installation location.

KIT CONTENTS

r4 Support pads

REMOVE THE LEVELING LEGS

Carefully lay the washer or dryer on its side to access the leveling legs on the bottom of the appliance. IMPORTANT: Do not lay the washer or dryer on its back! Do not remove the shipping bolts on the back side of the washer. The bolts must remain in place until the washer is returned to an upright position.

A

r4 Mounting screws

TOOLS YOU WILL NEED

Use an open-end wrench to remove the washer or dryer leveling legs. B

r7 mm Socket wrench

r9/16″ Open-end wrench

Back out and remove all 4 leveling legs

Show 4 more labels / short text on this page
rDrawer divider · rPhillips-head · screwdriver · or adjustable wrench
Page 44 of the GE PFMN440 user manual — B
Page 44 · click to enlarge
Page 44

3 PREPARE THE PEDESTAL

INSTALL THE PEDESTAL TO THE WASHER OR DRYER

A

Pull the drawer out as far as it will go.

Place the pedestal against the bottom of the unit. Check to be sure the drawer front is at the front of the washer. Align the holes in the pedestal with the holes in the bottom of the unit. Use a Phillips screwdriver to install the 4 bolts through the pedestal and into the unit—do not tighten.

A

B

Remove screws from drawer slides. Slide drawer out of the base and set aside.

B

FOR DRYERS ONLY:

Locate the 4 support pads from the parts package. Each pad has 2 protrusions that fit into the holes on top of the pedestal. Press the rubber pads into each set of corner holes on the top of the pedestal as shown.

Slide the pedestal toward the unit, until it is aligned front to back. Use a 7 mm socket wrench to securely tighten the bolts.

Page 45 of the GE PFMN440 user manual — B
Page 45 · click to enlarge
Page 45

INSTALLING THE PEDESTAL (if desired) (cont.)

LEVEL THE WASHER OR DRYER

REMOVE SHIPPING SCREWS

Stand the washer or dryer upright. Move it close to its final location. Make sure that the washer or dryer is level by placing a level on top. Check side to side and front to back. Use an open ended wrench to adjust the legs in and out. Tighten the lock nut against the bottom of the pedestal. NOTE: To minimize vibration, the locking nuts must be tight.

A

Remove the 4 shipping screws on the back side of the washer.

B

FINALIzE THE INSTALLATION

Refer to the washer or dryer Installation Instructions to complete the installation.

REINSTALL THE DRAWER

A

Check to be sure the slides are closed. Slide the drawer into the opening. Align the drawer supports to the slides on each side. Reinstall the original screws into each drawer slide. Tighten both screws. Open the drawer fully. Slide drawer divider into slots in the center of the drawer. The drawer should slide smoothly when you push it closed.

B

D

Drawer Divider

Page 46 of the GE PFMN440 user manual — PROBLEM Possible Causes What To Do
Page 46 · click to enlarge
Page 46

Before you call for service…

Troubleshooting Tips Save time and money! Review the charts on the following pages, or visit GEAppliances.com. You may not need to call for service.

PROBLEM Possible Causes What To Do

Dryer shakes or Some shaking/noise is normal. • Move dryer to an even floor space, or adjust leveling legs makes noise Dryer may be sitting unevenly as necessary until even.

  • Clothes take too long Improper or obstructed ducting
  • Check the Installation Instructions to make sure the to dry dryer venting is correct.
  • Make sure ducting is clean, free of kinks and unobstructed.
  • Check to see if outside wall damper operates easily.

Improper sorting • Separate heavy items from lightweight items (generally, a well-sorted washer load is a well-sorted dryer load).

Large loads of heavy fabrics • Large, heavy fabrics contain more moisture and take (like beach towels) longer to dry. Separate large, heavy fabrics into smaller loads to speed drying time.

Controls improperly set • Match control settings to the load you are drying.

Lint filter is full • Clean lint filter before every load.

Blown fuses or tripped circuit • Replace fuses or reset circuit breakers. Since most breaker dryers use 2 fuses/breakers, make sure both are operating.

Overloading/combining loads • Do not put more than one washer load in the dryer at a time.

Underloading • If you are drying only one or two items, add a few items to ensure proper tumbling.

The DRy dryness level Load consists of a mixture • When combining heavy and light fabrics in a load, was chosen but load is of heavy and light fabrics choose MORE DRy. still damp

Exhaust system is blocked • Inspect and clean exhaust system.

Control pads not Controls accidentally put in • Press START/PAUSE. responding service mode

Controls accidentally put in • Hold the LOCKbutton for 3 seconds to unlock the dryer. lock mode

Controls performed an • Reset the in-house breaker. incorrect operation

Dryer doesn’t start Control panel is “asleep” • This is normal. Press POWER to activate the control panel.

Dryer is unplugged • Make sure the dryer plug is pushed completely into the outlet.

Fuse is blown/circuit breaker • Check the building’s fuse/circuit breaker box and is tripped replace fuse or reset breaker. NOTE: Electric dryers use two fuses or breakers.

Dryer was accidentally paused • If the light on the START/PAUSE button is flashing, when starting Delay Start the dryer is paused. Press START/PAUSEto restart the countdown.

No numbers displayed Dryer is continuously • This is normal. When the dryer senses a low level of during cycle, only lights monitoring the amount of moisture in the load, the dryer will display the dry time moisture in the clothes remaining.

Page 47 of the GE PFMN440 user manual — PROBLEM Possible Causes What To Do
Page 47 · click to enlarge
Page 47

Before you call for service… GEAppliances.com

PROBLEM Possible Causes What To Do

Time Remaining The estimated time may change • This is normal. jumped to a when a smaller load than usual lower number is drying

Cannot make a The DRyNESS LEVEL, TEMP • This is normal. selection and the or OPTION that you are dryer beeps twice trying to select is incompatible with the chosen dry cycle

Dryer is running but The EXTEND TUMBLE • This is normal. During extended tumbling, the time 00 is displayed in option was chosen remaining is not displayed. The extended tumbling Time Remaining option lasts approximately 20 minutes.

Clean Lint Filter (message) POWER button was activated • Press START/PAUSE to begin a dry cycle and the message will disappear.

Dryer doesn’t heat Fuse is blown/circuit breaker • Check the building’s fuse/circuit breaker box and is tripped; the dryer may tumble replace both fuses or reset both breakers. Your dryer but not heat may tumble if only one fuse is blown or one breaker tripped.

Gas service is off • Make sure gas shutoff at dryer and main shutoff are fully open.

LP gas supply tank is empty • Refill or replace tank. Dryer should heat when utility or there has been a utility service is restored. interruption of natural gas (gas models)

Inconsistent drying times Type of heat • Drying time will vary according to the type of heat used. If you recently changed from an electric to a gas (natural or LP) dryer, or vice versa, the drying time could be different.

Type of load and • The load size, types of fabric, wetness of clothes and the drying conditions length and condition of the exhaust system will affect drying times.

Glow at the rear Heaters behind the drum • This is normal. Under certain drying conditions and of the drum room ambient lighting, the glow of the heaters may be visible at the rear of the drum.

Clothes are still wet The door was opened mid-cycle. • A dry cycle must be reselected each time a new load and dryer shut off The load was then removed from is put in. after a short time the dryer and a new load put in without selecting a new cycle

Small load • When drying 3 items or less, choose SPEED DRy or TIMED DRy.

Load was already dry except • Choose SPEED DRy or TIMED DRy to dry damp collars for collars and waistbands and waistbands. In the future, when drying a load with collars and waistbands, choose MORE DRy.

Dryer is not level • Move dryer to an even floor space or adjust leveling legs as necessary until even.

  • Clothes are wrinkled Overdrying
  • Select a shorter drying time.
  • Remove items while they still hold a slight amount of moisture. Select a LESS DRy or DAMP setting.

Letting items sit in dryer after • Remove items when cycle ends and fold or hang cycle ends immediately, or use the EXTEND TUMBLEoption.

Overloading • Separate large loads into smaller ones.

Page 48 of the GE PFMN440 user manual — PROBLEM Possible Causes What To Do
Page 48 · click to enlarge
Page 48

Before you call for service…

PROBLEM Possible Causes What To Do

  • Clothes shrink Some fabrics will naturally shrink
  • To avoid shrinkage, follow garment care labels exactly. when washed. Others can be safely washed, but will shrink
  • Some items may be pressed back into shape after drying.

in the dryer • If you are concerned about shrinkage in a particular item, do not machine wash or tumble dry it.

Greasy spots on clothes Improper use of fabric softener • Follow directions on fabric softener package.

Drying dirty items • Use your dryer to dry only clean items. Dirty items can with clean ones stain clean items and the dryer.

Clothes were not • Sometimes stains which cannot be seen when the completely clean clothes are wet appear after drying. Use proper washing procedures before drying.

Lint on clothes Lint filter is full • Clean lint screen before each load.

Improper sorting • Sort lint producers (like chenille) from lint collectors (like corduroy).

Static electricity can attract lint • See suggestions in this section under STATIC.

Overloading • Separate large loads into smaller ones.

Paper, tissue, etc., left in pockets • Empty all pockets before laundering clothes.

Static occurs No fabric softener was used • Try a fabric softener.

  • Bounce ® Fabric Conditioner Dryer Sheets have been approved for use in all GE Dryers when used in accordance with the manufacturer’s instructions.

Overdrying • Try a fabric softener.

  • Adjust setting to LESS DRy or DAMP .

Synthetics, permanent press • Try a fabric softener. and blends can cause static

Collars and waistbands The dryness monitor senses • Choose SPEED DRy or TIMED DRy to dry damp collars still wet at end of cycle that the body of the clothes and waistbands. In the future, when drying a load with is dry collars and waistbands, choose MORE DRy.

Slight variation This is normal • Due to the metallic properties of paint used for this unique in metallic color product, slight variations of color may occur due to viewing angles and lighting conditions.

Door is too foggy to see Steam condenses on inner door • This is normal. clothes during a steam cycle

Water seen on inside of Steam condenses on these • This is normal. door and top of lint filter surfaces when opening door after steam cycle

Small areas on clothes are Steam condenses on inner drum • Select a shorter cycle. damp after steam cycle

Cycle or cycle time selected too • Manually reduce cycle time for given cycle. long for size of load

Page 49 of the GE PFMN440 user manual — PROBLEM Possible Causes What To Do
Page 49 · click to enlarge
Page 49

Before you call for service… GEAppliances.com

PROBLEM Possible Causes What To Do

Small amount of water Inadequate load size for steam • Select a shorter cycle. Manually reduce cycle time on floor in front of dryer cycle selected, excess steam for given cycle. condenses inside cabinet and leaks out

Water on floor in back Loose water hose connection to • Tighten connection. of dryer valve

Hose missing rubber washer at • Install rubber washer provided with hose. connection with valve

Dryer makes water Water valve is open filling steam • This is normal. noises generator

Steam generator is dispensing • This is normal. steam into drum

Water drips from door Steam condenses on inner door • This is normal. when opened after a Steam Cycle

Cannot see steam at Steam released at different • This is normal. beginning of cycle

Cannot see steam at any The steam nozzle might be • CAll 800.GE.CARES to order nozzle replacement kit time during cycle clogged with debris from your WE25M71 or to request a technician to replace this for you. water supply

Garments still wrinkled Too many garments • Load fewer garments; manually increase time. after steam cycle

Dryer continues to Extend Tumble was selected • Ensure Extend Tumble option is not selected. tumble after display says Complete

Page 50 of the GE PFMN440 user manual — Warrantor: General Electric Company. Louisville, Ky 40225
Page 50 · click to enlarge
Page 50

GE Dryer Warranty. (For customers in the United States)

All warranty service provided by our Factory Service centers, or an authorized customer care® technician. To schedule service, on-line, visit us at GEAppliances.com, or call 800.GE.cARES (800.432.2737).

Staple your receipt here. Proof of the original purchase date is needed to obtain service

under the warranty.

Please have serial number and model number available when calling for service.

For The Period Of: We Will Replace:

One year Any part of the dryer which fails due to a defect in materials or workmanship. During this From the date of the limited one-year warranty, GE will also provide, free of charge, all labor and related service costs original purchase to replace the defective part.

Second year Any part of the dryer which fails due to a defect in materials or workmanship. During this From the date of the additional one-year limitedwarranty, you will be responsible for any labor or related service costs. original purchase

Second through The extra-large or super-capacity dryer drum and main electronic control board if any of these Fifth year parts should fail due to a defect in materials or workmanship. During this additional three-year From the date of the limited warranty, you will be responsible for any labor or related service costs. original purchase

What Is Not Covered (in the United States):

n Service trips to your home to teach you how to use

n Damage to the product caused by accident, fire, floods

the product.

or acts of God.

n Improper installation, delivery or maintenance.

n Incidental or consequential damage caused by possible

defects with this appliance.

n Failure of the product if it is abused, misused or used for

other than the intended purpose or used commercially.

n Damage caused after delivery.

n Replacement of the light bulb after its expected

n Product not accessible to provide required service.

useful life.

n Replacement of house fuses or resetting of circuit

breakers.

EXCLUSION OF IMPLIED WARRANTIES—your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor: General Electric Company. Louisville, Ky 40225

Page 51 of the GE PFMN440 user manual — What Is Not Covered (in Canada):
Page 51 · click to enlarge
Page 51

GE Dryer Warranty. (For customers in canada)

All warranty service provided by our Factory Service centres or an authorized technician. For service, call 1.800.561.3344.

Please have serial number and model number available when calling for service.

For The Period Of: We Will Replace:

One year Any part of the dryer which fails due to a defect in materials or workmanship. During this From the date of the limited one-year warranty, GE will also provide, free of charge, all labor and related service costs original purchase to replace the defective part.

Second year Any part of the dryer which fails due to a defect in materials or workmanship. During this From the date of the additional one-year limitedwarranty, you will be responsible for any labor or related service costs. original purchase

Second through The extra-large or super-capacity dryer drum and main electronic control board if any of these Fifth year parts should fail due to a defect in materials or workmanship. During this additional three-year From the date of the limited warranty, you will be responsible for any labor or related service costs. original purchase

What Is Not Covered (in Canada):

n Service trips to your home to teach you how to use

n Damage to the product caused by accident, fire, floods

the product.

or acts of God.

n Improper installation, delivery or maintenance.

n Incidental or consequential damage caused by possible

defects with this appliance.

n Failure of the product if it is abused, misused or used for

other than the intended purpose or used commercially.

n Damage caused after delivery.

n Replacement of the light bulb after its expected

n Product not accessible to provide required service.

useful life.

n Replacement of house fuses or resetting of circuit

breakers.

EXCLUSION OF IMPLIED WARRANTIES—your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

This warranty is extended to the original purchaser and any succeeding owner for products purchased in canada for home use within canada. In-home warranty service will be provided in areas where it is available and deemed reasonable by Mabe to provide.

WARRANTOR IS NOT RESPONSIBLE FOR CONSEQUENTIAL DAMAGES.

Warrantor: MABE CANADA INC.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the GE PFMN440

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE PFMN440

Be the first to ask — other owners or our team will answer.

Original document

GE PFMN440 manual PDF

156 pages·12.8 MB·Clothes Dryer·PDF
Click any page above to open it here