GE Monogram ® Installation Instr uctions Professional V ent Hoods 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS 36" Models ZV671WSS, ZV681YSS ZV670WSS, ZV680YSS 30" Models ZV370YSS,.
2 Before you begin—Read these instr uctions completely and car efully . IMPORT ANT: Save these instr uctions for local inspector’s use. IMPORT ANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES. NOTE TO INST ALLER: Be sur e to leave these instr uctions with the Consumer .
3 Design Information Professional Vent Hoods Models Available These hoods can be installed into a soffit, or when there is no soffit, they can be installed directly onto a wall. 48" and 36" wide models are available with different appearances.
4 Design Information Professional Vent Hoods These vent hoods must be installed 30" Min. and 36" Max. above the cooking surface. Installation will be easier if the vent hood is installed before the range or cooktop installation. Product Dimensions & Clearances The rating plate is located behind filter cutouts.
5 Design Infor mation Professional Vent Hoods Advance Planning Ductwork planning • Deter mine the exact location of the vent hood. • Plan the route for venting exhaust to the outdoors.
6 Installation Preparation Professional Vent Hoods Duct fittings T otal Equivalent Quantity Equivalent Duct Piece Dimensions Length* Used Length Round, 1 ft. straight (per foot length) 3 -1 ⁄ 4" x 12" or 1 ft. 3-1/4" x 24" (per foot straight length) 90 ° elbow 15 ft.
7 Installation Professional Vent Hoods T ools & Materials Required (not supplied) W all Mount Installation: • Six, 5/16" lag scr ews, 2" long with washers, all models (provided). Sof fit Installation: • Six, 5/16" lag scr ews, 2" long with washers, all models (provided).
8 Installation Professional Vent Hoods Locate the hardware accessor y box packed with range hood and check contents. 2 Check Installation Hardware Step W e recommend that the vent hood and/or duct cover be on site befor e final framing and wall finishing to mor e accurately locate the ductwork and electrical ser vice.
9 Installation Professional Vent Hoods NOTE: A decorative duct cover is available for wall mount installations. The duct cover conceals the duct run fr om the top of the hood to the ceiling. Choose the 6" or 12" cover based upon installation height of the vent hood.
10 Installation Professional Vent Hoods • Drill 3/16" pilot holes through the shims and into the soffit studs. • Hold the hood against the soffit and secure with 6 lag screws with washers. • For additional support and to minimize vibration during operation, we recommend that the hood be secured to the back wall.
11 Installation Professional Vent Hoods • Drill 3/16" pilot holes, approximately 1-1/2" deep, in all mounting screw locations. • Hold the hood in position and drive lag screws in top left and right mounting holes. NOTE: 5/16" hanger bolts can be used in the two top locations.
12 Installation Professional Vent Hoods 5 Step Connect Electrical V erify that power is turned off at the sour ce. CAUTION If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer . When house wiring is aluminum, be sure to use U.
13 Installation Professional Vent Hoods Install Duct Cover 8 “WSS” Duct Covers • Fasten the duct cover to the top of the hood with 2 screws. Step Secure with Screws “YSS” Duct Covers • Install one side piece to the top of the hood with 2 screws.
14 Notes Professional Vent Hoods.
15 Notes Professional Vent Hoods.
Pub. No. 49-8816-1 Dwg. No. 164D3333P060 1999 GE Appliances (N.D. 173) 5/99 10657-1 Monogram. ® General Electric Company Louisville, KY 40225 Note: While performing installations described in this book, safety glasses or goggles should be worn.
An important point after buying a device GE Monogram ZV881WSS (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought GE Monogram ZV881WSS yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data GE Monogram ZV881WSS - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, GE Monogram ZV881WSS you will learn all the available features of the product, as well as information on its operation. The information that you get GE Monogram ZV881WSS will certainly help you make a decision on the purchase.
If you already are a holder of GE Monogram ZV881WSS, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime GE Monogram ZV881WSS.
However, one of the most important roles played by the user manual is to help in solving problems with GE Monogram ZV881WSS. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device GE Monogram ZV881WSS along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center