Merlin™
Point of Use
Drinking Water System
Installation and Maintenance Manual


Read and follow all steps and guides carefully before installing and using your reverse osmosis system.
Do not use this product to make safe drinking water from non-potable water sources. Do not use the system on microbiologically unsafe water, or water of unknown quality without adequate disinfection before or after the system.
This reverse osmosis system contains replaceable components (membrane elements). These components are critical for the effective reduction of total dissolved solids and specific contaminants that are listed in the Appendix.
The Merlin drinking water system does not have a monitoring device for contaminants. To verify that the system is performing satisfactorily the product water should be tested periodically by the system’s installing dealer every six months. See the back cover of this manual for the installing dealer’s contact information.
Consult your local public works department for plumbing and sanitation codes. Follow your local codes if they differ from this manual.
The reverse osmosis system works on water pressures of 40 psi (2.8 bar) minimum to 80 psi (5.5 bar) maximum. Water pressure can be reduced by installing a pressure reducing valve in the water supply pipe to the RO system. A booster pump should be used for low pressure applications.
Do not install the reverse osmosis system in extreme hot or cold temperatures. Temperature of the water supply to the reverse osmosis system must be between 40°F (°C) and 100°F (38°C). Do not install on hot water lines.
The reverse osmosis membranes contain a foodgrade preservative for storage and shipment. New membranes should be flushed for one hour prior to use. This flush removes the preservative. The preservative is not harmful but makes the product water taste objectionable.
2 SAFETY GUIDES Rev B

Your Merlin™ Reverse Osmosis (RO) Drinking Water System is a water treatment unit. It uses water pressure to reverse a natural physical process called osmosis. Water, under pressure, is forced through a semi-permeable membrane to filter out minerals and impurities. Clean drinking water goes to the faucet. Minerals and impurities are sent to the drain with RO waste water.
The system includes replaceable filters and membrane elements. The prefilter removes sand, silt, dirt, rust particles, other sediments, and chlorine from the water supply before they enter the RO membrane elements. The postfilter removes any tastes and/or odors that may remain in the water after passing through the RO membrane elements.

The reverse osmosis system is purchased as an installation kit. Before starting installation check that the following components are available:

The reverse osmosis system is designed for installation under a sink, usually in the kitchen or bathroom. The RO assembly can be placed on the cabinet floor in any position that does not apply pressure on the disconnect elbows. The RO product water faucet installs on the sink or on the countertop next to the sink.
The RO system can also be located in a location away from the faucet. A nearby water source and drain point are required.
Water Supply: To provide supply water to the RO system inlet, a feed supply fitting is required or install pipe fittings as needed.
Drain Point: A suitable drain point is needed for reject water from the RO system. A floor drain, laundry tub, standpipe, sump, etc. are all acceptable. A sink p-trap drain adapter is included to install as an optional drain point where codes permit.
All components and tubing should be located in an area which is not exposed to freezing temperatures. Do not expose unit or tubing to direct sunlight.
Dispensing Faucet: The faucet should be placed near the sink where drinking water is normally obtained. Convenience of use (filling of water pitchers and glasses) and an open area beneath the faucet under the sink for attaching product and drain tubing are considerations. A 2-inch diameter flat surface is required above and below the installation site. The thickness of mounting surface should not exceed 1-1/4 inches. Avoid any strengthening webbing on the underside of the sink.
RO Manifold Assembly: The manifold can be installed on either the right or left side of the under-sink area or cabinet. Installation in the basement is also an option. One possible location is near the laundry/utility sink where cold potable water and drain access are close. The location chosen should allow adequate clearance and accessibility for membrane element changes.
Feed Water Connection: The feed water valve should be located as close to the manifold assembly as possible. USE A POTABLE COLD WATER SUPPLY ONLY. Softened water is preferred as it will extend the life of the RO membrane element.

Drain Connection - Depending on plumbing codes, the waste water may need to go to drain through an anti-siphon air gap. A detachable faucet air gap is included with the system. If discharging into the utility sink or standpipe, an air gap of greater than 1.5 inches above the flood rim must be provided.
Do not connect the system drain line to the dishwasher drain or near the garbage disposal. Back pressure from these units may cause the air gap to overflow.

In restricted under-sink areas, it may be easier to install the faucet first. Allow adequate tubing lengths for final system placement.

Figure 1 Typical Under-Sink Installation



Comply with local plumbing codes. A typical connection using a water supply valve is shown. The feed water valve is not included with system. Contact supplier for this item.
Cold water pipes vary in size and style. The installer will determine type of valve that will be used. Install a valve on the cold water supply pipe to adapt 1/2-inch OD tubing. If threaded fittings are used, be sure to use pipe joint compound or Teflon tape on outside threads.
Turn the valve off.
Water Supply Valve

Follow the instructions in the Appendix for installation of the Drain Boa™.
The drain adapter is designed to fit 1-1/2-inch (3.8 cm) sink drain pipe.
The adapter installs directly to the sink tailpiece.
A. Prepare Mounting Hole
Gasket Air Gap Module

B. Assemble Faucet
The tubing and fasteners are assembled to the faucet before the faucet is placed in position. If not using the air gap module, skip to step #3.
The connections to the faucet should be complete, the remaining connections are:
A typical connection is shown in Figure 4.

Figure 4 Side View and Cutaway of Tubing Fitting
Install the postfilter inline with the blue permeate tubing. Secure tubing with collet lock clips.
The drain adapter has a rubber inlet that accepts the 3/8-inch black drain tube or the 1/2-inch red tube. The 3/8-inch black tubing will connect here if the faucet is not using the air gap module.
When the tubing is in position, use the supplied hose clamps to secure the connection.

Feed Water Valve (Not Supplied)
The feed water valve attaches to a nearby cold water supply line. The installer will determine the type and size of valve that will be installed. This valve connects to the 1/2-inch natural tubing.
If the flush tank is used, the 1/4-inch blue tubing will be used to connect to the top fitting of the RO assembly manifold. Remove the plug and push the tubing into the fitting until it stops.
The RO Assembly includes the following components: sumps (3), support leg, prefilter, RO membrane elements (2), and postfilter. The tubing is attached to the manifold by the elbow connectors. When choosing a location for the system, allow enough tubing for it to be moved for periodic servicing of the filters and membrane elements.
Figure 5 Merlin RO Assembly
Flush Tank (Optional)

The Merlin assembly should be positioned in one of two ways.
The first position is with the unit standing upright using the support leg with the sumps horizontal. The tubing is directed to provide the best fit.
The second position, sets the unit on end so the manifold is horizontal and the sumps are pointing up. The tubing is directed upward and the locking bar is down to lock the tubing connections.
See illustrations at left.
The table below shows the coding system for the fitting connections. Each fitting has a unique “keyed” socket on the manifold. Each fitting also has a graphic symbol molded into the elbow with a corresponding symbol on the manifold.
Connector Symbol Connection Tubing Color
C Feed-Inlet Natural
U Concentrate Black Product Blue

When all of the connections have been made, use the locking bar to hold the fittings in position. Match the symbols on the locking bar to the corresponding symbols on the manifold.
Figure 6 Locking Bar
To check for leaks, the system must be filled with water and brought up to operating pressure.
Symbols · Pressure Test System

The RO system is now ready for use.
The components of the RO system are designed to function with minimal maintenance. However, the membrane elements and filters will need to be replaced on a regular schedule.
Run the system for at least two minutes each day for optimal performance.
The carbon/sediment prefilter removes sediment and certain chemicals, such as chlorine, from the water. Depending on water use and the amount of impurities, this filter should be replaced every six to twelve months.
Whenever the prefilter is replaced, the postfilter should also be replaced.
The functional life of the RO membrane elements will vary based on feed water quality. Product water should be tested periodically to verify the membrane elements are performing properly. For most residential applications, the RO membrane elements should be replaced every two to four years.
TO CARE FOR THE RO SYSTEM 15 Rev B

If changing the membrane elements, the prefilter and postfilter should also be changed.
16 REPLACEMENT OF THE PREFILTER, POSTFILTER, AND RO MEMBRANE ELEMENTS Rev B

A. Remove membrane sumps. Remove and discard used
elements. B. Remove new elements from packaging.
C. Lubricate element O-rings, brine seals, and sump O-rings
with silicone lubricant. D. Securely insert O-ring end of elements into manifold. See
Figure 8. E. Replace sumps and hand-tighten.
A. The manifold should be positioned flat with the sump
connections facing up.
Prefilter Center Opening Membrane Element Locations
REPLACEMENT OF THE PREFILTER, POSTFILTER, AND RO MEMBRANE ELEMENTS 17 Rev B

B. Pour a tablespoon (15 milliliters) of chlorine bleach into the
center opening of the prefilter sump connection. See Figure 8.
A. Remove new prefilter from packaging. Ensure gaskets are
secure. Insert prefilter into proper opening on manifold. B. Lubricate sump O-ring with silicone lubricant. C. With the prefilter element in place, screw the sump into the
connection. Do not overtighten.
A. To unlock the fittings from the tubing, push down on the collet
sleeves and pull the tubing out. B. Discard the exhausted postfilter. C. To prevent leaks, cut the tubing back approximately
1/4 inch prior to connecting the new postfilter. Make sure flow direction arrow aligns with water path. Reinsert tubing and collect locks.
18 REPLACEMENT OF THE PREFILTER, POSTFILTER, AND RO MEMBRANE ELEMENTS Rev B

The RO system is now ready for use.
REPLACEMENT OF THE PREFILTER, POSTFILTER, AND RO MEMBRANE ELEMENTS 19 Rev B

20 APPENDIX Rev B

MERLIN COMPONENTS 21 Rev B
OnDemand RO

1255052 Complete Merlin system
1239705 Sump - interchangeable for all 3 positions
1244617 Manifold - complete
1240564 Drain Boa Kit
1240620 3/8-inch Black Tubing - 500 foot roll - John Guest Brand
1240621 3/8-inch Blue Tubing - 500 foot roll - John Guest Brand
1240622 1/2-inch Natural (clear) - 250 foot roll - John Guest Brand
1240623 1/2-inch Red Tubing - 250 foot roll - John Guest Brand
1240117 1/2-inch Feed Disconnect Elbow - White
1240118 3/8-inch Permeate Disconnect Elbow - Blue
1240116 3/8-inch Drain Disconnect Elbow - Dark Gray
1240119 1/4-inch Flush Disconnect Elbow - Light Blue
1255693 Complete Fittings and Locking Bar Kit
1255736 Complete Tubing Install Kit
Spare parts are available through your installing water treatment dealer.
22 MERLIN PARTS LIST Rev B

1261345 Merlin Flush Kit (Accumulator tank and 1/4-inch tubing)
1240619 1/4-inch Blue Tubing - 500 foot roll - John Guest Brand
1240632 Inlet Booster Pump, 110V/60Hz
1013501 Silicone Lubricant Pack
1240629 Feed Valve Tee - 1/2" x 1/2" x 1/2" OD Tubing - G.A. Murdock USA
1240630 Feed Valve Tee - 5/8" x 5/8" x 1/2" OD Tubing - G.A. Murdock USA
1262403 Feed Valve Tee - 5/8" x 5/8" x 1/2" OD Tubing -SeaTech
1262404 Feed Valve Tee - 14 mm x 14 mm x 1/2" OD Tubing -SeaTech
1262406 Feed Valve Tee - 15 mm x 15 mm x 1/2" OD Tubing -SeaTech
1262407 Feed Valve Tee - 3/8" x 3/8" threaded x 1/2" Tubing -SeaTech
1262408 Feed Valve Tee - 1/2" x 1/2" threaded x 1/2" Tubing -SeaTech
1262847 10-micron Sediment Prefilter
— Post Filter Mounting Clip Kit
Part Number Description Recommended
1240626 Individual Collet Lock Clip- 1/4-inch Red - John Guest PN PIC1808R-X John Guest USA
1240627 Individual Collet Lock Clip- 3/8-inch White - John Guest PN PIC1812W-X John Guest USA
1240628 Individual Collet Lock Clip- 1/2-inch Blue - John Guest PN PIC1816B-X John Guest USA
1240624 1/4-inch JG Plug - John Guest PN P10808S John Guest USA
1240625 Faucet Connection Fitting - John Guest PN CI3212U7S John Guest USA
Spare parts are available through your installing water treatment dealer.
MERLIN PARTS LIST 23 Rev B
Part Number Description · Source


Performance Specifications1, 2
Minimum Maximum Average Permeate Flow Rate 0.33 gals/min (1.25 Lpm) 0.75 gals/min (2.84 Lpm) 0.50 gals/min (1.89 Lpm) TDS Rejection (NaCl)3 90% 99% 93%
Minimum and Maximum Operating Conditions Condition Minimum Maximum Inlet Pressure 40 psi (2.76 bar) 80 psi (5.52 bar) Inlet Temperature 40°F (4.44°C) 100°F (37.78°C) Inlet TDS 50 mg/L 2,000 mg/L Inlet Hardness 0 mg/L (0 grain) 171 mg/L (10 grain) Inlet Chlorine 0 mg/L 1.0 mg/L Inlet Iron 0 mg/L 0.1 mg/L Inlet Manganese 0 mg/L 0.05 mg/L Inlet pH 4 10 Inlet Turbidity 0 1 NTU
24 DIMENSIONS Rev B


DIMENSIONS 25 Rev B

Contaminant Influent (avg.
Effluent (ave.
Effluent (max.
0.049 0.00265 0.00612 94.6%
Barium 11.1 0.189 1.9 98.3%
Cadmium 0.0307 0.0000704 0.0000704 99.8%
Chromium (VI) 0.353 0.00742 0.0147 97.9%
Chromium (III) 0.312 0.000624 0.00453 99.8%
Copper 3.22 0.0721 0.0721 97.8%
Fluoride 8.11 0.51 0.65 93.7%
Lead 0.159 0.000628 0.000628 99.6%
Nitrate/Nitrite (as N)b
28.96 6.26 7.55 78.4%
Selenium 0.113 0.00249 0.003 97.8%
Total Dissolved Solids (TDS) 726 74.8 94.8 89.7%
a. This system has been tested for the treatment of water containing pentavalent arsenic (also known as As(V),
As(+5), or arsenate) at concentrations of 0.050 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free-chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramines (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts section of the Merlin system performance data sheet.
b. This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L
nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 40 psi (2.76 bar) or greater.
To verify the level of nitrate/nitrite in the product water use the test strips that have been included with the system. Follow the instrucions that are on the test strip packaging.
The level of nitrate/nitrite in the product water should be within local standards before placing the Merlin system into operation.
Testing performed under standard laboratory conditions. Actual results may vary.
26 DIMENSIONS Rev B

Average System Recovery means the percentage of the influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when operated as designed (without a pressurized storage tank).
Average System Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage.
Efficiency rating is identical to recovery rating when the system is tested without a storage tank or when a storage tank is bypassed.
Minimum and Maximum Operating Conditions
Inlet Water Condition Minimum Maximum
Pressure 40 psi (2.76 bar) 80 psi (5.52 bar)
Temperature 40°F (4.44°C) 100°F (37.78°C)
TDS 50 mg/L 2,000 mg/L
Hardness 0 mg/L 171 mg/L
Chlorine 0.0 mg/L 1.0 mg/L
Iron 0.0 mg/L 0.1 mg/L
Manganese 0.0 mg/L 0.05 mg/L
Actual system performance will vary depending on varying water temperature and pressure, TDS levels and inlet water chemistry. Operating the system in water conditions outside the minimum or maximum operating parameters may result in reduced system performance and membrane element life.
System manufactured by:
GE Infrastructure Water & Process Technologies
5720 N. Glen Park Road Milwaukee, WI 53209-4454 U.S.A.
Direct spare parts and service inquiries to the system’s installing dealer.
DIMENSIONS 27 Rev B

Contact your installing dealer for spare parts or service:

©Copyright 2004 General Electric Company
Printed in the USA P/N 1262366 Rev B