Page 1 of the GE JVB98 user manual — 49-80437 11-06 JR
Page 1 · click to enlarge
Page 1

ge.com

Vent Systems

Downdraft

Safety Instructions 2, 3, 7

Owner’s Manual

& Installation

Operating Instructions Cooking Tips 5 Raise/Lower Switch 4 Using the Cooktop 4 Using the Downdraft System . . .4

Instructions

JVB37 JVB67 JVB94 JVB98

Care and Cleaning Grease Filters 5 Painted or Metal Surfaces 5 Stainless Steel Surfaces 5

Installation Instructions Advance Planning 8, 9 Before You Begin 6 30″ Cooktop/Downdraft Units JVB37 and JVB94 10 36″ Cooktop/Downdraft Units JVB67 and JVB98 11 Dimensions and Clearances . .7, 8 Ductwork 8, 13, 15 Electrical and Gas Location 8 Installation Possibilities 9 Installing the Downdraft Vent System 10–17 Optional Kits 17 Power Supply 12 Raise/Lower Switch 16 Venting Options 14

Troubleshooting Tips 18

Consumer Support Consumer Support 20 Warranty 19

Write the model and serial numbers here:

You can find them on a label on the side of the blower housing.

49-80437 11-06 JR

Model # · Serial #

Page 2 of the GE JVB98 user manual — Operating Instructions Safety Instructions Installation Instructions Troubleshooting Tips Consumer Support
Page 2 · click to enlarge
Page 2

Operating Instructions Safety Instructions Installation Instructions Troubleshooting Tips Consumer Support

PLEASE NOTE: The downdraft vent system you have purchased was designed to be used with GE, GE Profile and GE Profile Performance cooktops listed in this manual.

SAFETY PRECAUTIONS WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended

by the manufacturer. If you have questions, contact the manufacturer. B. Before servicing or cleaning unit, switch

lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. B. NEVER PICK UP A FLAMING PAN—

power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. C. Do not use this unit with any solid-state speed

You may be burned. C. DO NOT USE WATER, including wet

dishcloths or towels—a violent steam explosion will result. D. Use an extinguisher ONLY if:

control device. D. This unit must be grounded. CAUTION – For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. CAUTION – To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.

1. You know you have a Class ABC extinguisher, and you already know how to operate it. 2. The fire is small and contained in the area where it started. 3. The fire department is being called. 4 . You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.
Page 3 of the GE JVB98 user manual — READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS
Page 3 · click to enlarge
Page 3

ge.com

Consumer Support Operating Instructions Safety Instructions Installation Instructions Troubleshooting Tips

SAFETY PRECAUTIONS WARNING – TO REDUCE THE RISK OF A COOKTOP GREASE FIRE: A. Never leave surface units unattended at high

settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. B. Always turn hood ON when cooking on high

part of your hood unless it is specifically recommended in this manual. All other servicing should be referred to a qualified technician.

heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). C. Clean ventilating fans frequently. Grease should

IPVC sewer pipe can be used as duct under

concrete slab if allowed by local code board.

IMake sure all fingers are away from the

not be allowed to accumulate on fan or filter. D. Use proper pan size. Always use cookware

downdraft top when it is lowered.

appropriate for the size of the surface element. WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Installation work and electrical wiring must be

done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. B. Sufficient air is needed for proper

combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. C. When cutting or drilling into wall or ceiling,

do not damage electrical wiring and other hidden utilities. D. Ducted fans must always be vented

to the outdoors.

SERVICING

Be sure electrical power is off before servicing the unit.

It may be necessary to remove the downdraft blower system in order to service components such as the blower motor or air vent mechanism.

Disconnect power to the cooktop and remove it first. Reverse the steps in the Install the Downdraft section to remove the blower.

Service parts are available from a GE Service and Parts Center.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS

Page 4 of the GE JVB98 user manual — Raise/Lower Switch
Page 4 · click to enlarge
Page 4
Safety InstructionsUsing the downdraft system. Raise/Lower Switch (30″ models only) Turn the downdraft blower ON by pressing NOTE: For most convenient operation, set the the raise/lower switch located at the top blower to the speed you use most often. The right of the vent. Place your finger on the blower will come on to this speed whenever “center” of the switch and hold until you the unit is raised. observe the vent moving, then release. The air vent will rise. Use the selector switch to turn the blower ON, OFF or to change the blower speed. The vent may be lowered by again pressing the raise/lower switch at the top right side of the vent. The blower, if left on, will automatically go off when the vent is On some models, the Raise/Lower lowered. switch is located at the top right of the vent. Use the selector switch to turn the blower ON, OFF or to change the blower speed. Remote Raise/Lower Switch (36″ models only) The 36″ models have a remote raise/lower switch. It operates in the same manner as the switch located on the vent. This switch may be located beside the cooktop or in a convenient location. Raise/Lower switch location may vary. Using the Cooktop CAUTION: I To avoid injury, be sure fingers are clear Be careful when raising of the downdraft cover when it is being or lowering the downdraft. Be sure pots, pot handles lowered. and other objects are clear of the downdraft I Keep hands and fingers away from all and cannot be struck or tipped by the downdraft downdraft parts. being raised. NOTE: There is a slight trim overhang at each end of the vent. 4 Operating Instructions Installation Instructions Troubleshooting Tips Consumer Support
Page 5 of the GE JVB98 user manual — Painted or Metal Surfaces
Page 5 · click to enlarge
Page 5

ge.com

Consumer Support Operating Instructions Safety Instructions Installation Instructions Troubleshooting Tips

Cooking Tips

The high air movement of this downdraft system can increase the cooking times for some foods. It may take longer to reach high cooking temperatures if the downdraft is turned to high right away. Adjust the fan speed for best cooking results.

Canning

When canning foods in a water-bath canner, a gentle but steady boil must be maintained continuously for the required time.

When canning foods in a pressure canner, the pressure must be maintained continuously for the required time.

For best results when heating oil for deep frying or when boiling water, use the front surface units or wait until the water is boiling or the oil is at frying temperatures before turning on the downdraft.

Use of the blower at HIGH speed when canning may reduce the temperature enough to stop boiling. While canning, we recommend using the downdraft at LOW speed and using the front surface unit.

The downdraft may not completely capture all the steam from pans on the front burners.

Care and cleaning of the downdraft system.

Grease Filters

The efficiency of your downdraft depends on a clean filter. Frequency of cleaning depends on the type of cooking you do. Grease filters should be cleaned at least once a month. Never operate the downdraft without the filters in place.

be used to remove embedded soil. Rinse, shake and remove moisture before replacing.

Filters may also be cleaned in the dishwasher.

With careful handling, the filter will last for years. If replacement becomes necessary, order the part from your dealer.

To remove: Pull the filters out by grasping them and pulling straight up.

To cleanSoak and then agitate in a hot detergent solution. Light brushing may

Painted or Metal Surfaces

Clean greasy surfaces frequently, using a mild detergent.

Do not use abrasive cloth, steel wool pads or scouring powder because they will mar the surface.

Stainless Steel Surfaces (on some models)

Do not use a steel wool pad; it will scratch the surface.

To inquire about purchasing stainless steel appliance cleaner or polish, or to find the location of a dealer nearest you, please call our toll-free number:

To clean the stainless steel surface, use warm sudsy water or a stainless steel cleaner or polish. Always wipe the surface in the direction of the grain. Follow the cleaner instructions for cleaning the stainless steel surface.

National Parts Center 1.800.626.2002

ge.com

Page 6 of the GE JVB98 user manual — PARTS INCLUDED
Page 6 · click to enlarge
Page 6

Installation Downdraft Vent Instructions System

If you have questions, call 800.GE.CARES or visit our Website at: ge.com

BEFORE YOU BEGIN

REMOVE PACKAGING

Read these instructions completely and carefully.

Open the carton and remove parts package. Check contents to be sure all pieces are present. (The parts package may be attached to the power cord.)

  • IMPORTANT — Save these instructions for local inspector’s use.

Remove the shipping materials. Remove the carton and set aside. The carton can be used as a pad when changing or adjusting vent direction.

  • IMPORTANT — Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Note – This appliance must be properly grounded.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the Warranty.

PARTS INCLUDED

TOOLS YOU WILL NEED

Remote raise/lower assembly (for 36″ models only)

Wire box (2) and screws (4)

Show 17 more labels / short text on this page
Stabilizing brackets · (all models) (4) · Flat-blade screwdriver · Carpenter square · Pliers · Duct tape · Plastic strain · Wire and white · relief (2) · connector (1) · Jig saw · Ductwork to suit · Switch cover · Attachment · plate (1) · the installation · bracket (1)
Page 7 of the GE JVB98 user manual — B
Page 7 · click to enlarge
Page 7

DIMENSIONS AND CLEARANCES

81⁄2″

A

71⁄2″

21⁄4″

B

31⁄8″

33⁄4″

61⁄4″

71⁄8″

101⁄2″

33⁄8″

A B 30″ Models 30″ 281⁄4″ 36″ Models 36″ 333⁄4″

WARNING! INSTALLATION SAFETY INSTRUCTIONS

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

The countertop must be at least 26″ deep with a flat surface area of 231⁄2″ or more, front to back. (NOTE: Curved front models require 235⁄8″ minimum flat surface area.) In addition, other clearances to the front edge of the countertop must be considered.

A

Installation work and electric wiring

must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

  • See specific cutout illustrations with your cooktop model to determine requirements.

B

Ducted fans must always be vented to

the outdoors.

  • A countertop with a raised lip or rolled front edge may not allow enough flat area for installation.

When cutting or drilling into wall or

ceiling, do not damage electrical wiring and other hidden utilities. WARNING — To reduce the risk of fire, use only metal ductwork.

Show 4 more labels / short text on this page
2″ · 27″ · Flat surface area · 24″
Page 8 of the GE JVB98 user manual — REMOTE SWITCH (for 36 ″ models only)
Page 8 · click to enlarge
Page 8

ADVANCE PLANNING

CLEARANCES

DUCTWORK

  • Installation must conform with local codes.
  • The downdraft system with blower, motor and duct work will occupy the cabinet below the countertop and cooktop.
  • The blower/motor assembly can be located below the cabinet floor. The assembly will fit between 16 ″ floor joists. In this installation a transition to 6 ″ round is required.
  • The blower motor assembly can also be installed outdoors. Order JXBC67 for remote blower installations outdoors.
  • Refer to Dimensions and Clearances for information on appropriate placement and necessary clearances when planning installation.
  • Refer to your specific cooktop installation instruction for other appropriate clearances.
  • Avoid placing cabinetry directly above the cooking surface when possible.
  • If cabinetry is used above the cooking surface: Installation must conform with local codes. Use cabinets no more than 13 ″ deep. Maintain 30 ″ minimum clearance between cooktop and unprotected cabinets directly above cooktop. If clearance is less than 30 ″ , protect cabinet bottoms with flame-retardant millboard at least 1/4 ″ thick or gypsum board at least 3/16 ″ thick covered with 28 gauge sheet steel or .02 ″ thick copper. Clearance between cooktop and protected cabinetry must not be less than 24 ″. EXCEPTION: Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.
  • Working areas adjacent to the cooktop should maintain 18 ″ minimum clearance between countertop and cabinet bottom.

Prepare ductwork to vent to the outdoors.

  • Use the shortest and straightest duct run possible. The maximum permissible length for duct run is 150 feet. Refer to Duct Fittings chart to calculate equivalent length for various duct configurations.
  • The downdraft blower system is designed to use 3 1 ⁄ 4 ″ x 10 ″ ductwork. It can be transitioned to 6 ″ round.
  • Ductwork MUST be vented to the outside— never into a crawl space, attic or other enclosed space.
  • Determine the need for a wall cap or roof cap. Purchase the cap in advance from your home building center or plumbing supply.

COOKTOP ELECTRICAL AND GAS LOCATION

  • Plan the placement of the electrical outlet and gas (if used) carefully. Gas or electrical outlets cannot be placed on the back wall of the cabinet because it may interfere with the downdraft plenum. Install a standard electrical outlet within reach of the vents’ 2 foot long power cord.
  • The vent and a gas cooktop combination can operate from the same 120V standard duplex outlet.
  • Electric cooktops must operate from a separate 240V junction box.

REMOTE SWITCH (for 36 ″ models only)

The downdraft vent has a separate raise/lower switch. Plan to install the switch in a convenient location outside of the vent/cooktop cutout.

Page 9 of the GE JVB98 user manual — INSTALLATION POSSIBILITIES
Page 9 · click to enlarge
Page 9

INSTALLATION POSSIBILITIES

When the kitchen design calls for an against the wall installation, move 24″ deep base cabinet forward, 3″ to 5″. Filler panels can be angled or flat to fill the space between adjacent cabinets.

In an island or peninsula, the countertop can be extra deep to provide seating opposite of the cooktop. Adding base cabinets on each side of the cooktop provides extra storage and countertop work space.

Maintain cutout clearances to front edge as specified.

Countertop overhang per cooktop clearances must be maintained

30″ to 42″

Base sink 30″ Min. for JVB37 and JVB94 36″ Min. for JVB67 and JVB98

Show 9 more labels / short text on this page
18″ · Base to sink · 18″ · Filler panel · Filler panel · Base cabinet · End panel · Cover · panel
Page 10 of the GE JVB98 user manual — 30 ″ COOKTOP/DOWNDRAFT UNITS JVB37 AND JVB94
Page 10 · click to enlarge
Page 10

INSTALLING THE DOWNDRAFT VENT SYSTEM

30 ″ COOKTOP/DOWNDRAFT UNITS JVB37 AND JVB94

81⁄2″

  • NOTE: Before you begin, measure and mark depth to ensure that adequate flat countertop surface is available. Identify the cutout illustration for the cooktop model you are installing with this downdraft vent system.
  • Draw lines on the countertop to follow as a cutting guide.
  • Make sure sides of the opening are parallel and rear and front cuts are exactly perpendicular (right angle) to sides.

21⁄8″*

3/8″ Minimum flat countertop behind

21⁄2″ Minimum**

281⁄2″

Model NumberCombined Cutout Depth JP340 JP346 JP355 JP356 JP910 JP930 JP940 JP950 PP912 PP932 PP942 PP945 PP950 JGP337 JGP94022-1/4″ JP328 JGP328 JGP330 JGP933 JGP94522-3/8″

**Includes 1/8″ gap between cooktop and vent trim **Required to maintain UL or CSA approvals

30″ · cutout required · See table

Page 11 of the GE JVB98 user manual — 36 ″ COOKTOP/DOWNDRAFT UNITS JVB67 AND JVB98
Page 11 · click to enlarge
Page 11

36 ″ COOKTOP/DOWNDRAFT UNITS JVB67 AND JVB98

81⁄2″

  • NOTE: Before you begin, measure and mark depth to ensure that adequate flat countertop surface is available. Identify the cutout illustration for the cooktop model you are installing with this downdraft vent system.
  • Draw lines on the countertop to follow as a cutting guide.
  • Make sure sides of the opening are parallel and rear and front cuts are exactly perpendicular to sides.

21⁄8″*

3/8″ Minimum flat countertop behind

21⁄2″ Minimum**

Model NumberCombined Cutout Depth JP62621-1/8″ JP655 JP960 JP970 JP980 PP962 PP972 PP975 PP980 JGP97021-3/4″ JGP628 JGP630 JGP637 JGP963 JGP97521-7/8″

**Includes 1/8″ gap between cooktop and vent trim **Required to maintain UL or CSA approvals

Show 4 more labels / short text on this page
36″ · cutout required · 34″ · See table
Page 12 of the GE JVB98 user manual — POWER SUPPLY
Page 12 · click to enlarge
Page 12

INSTALLING THE DOWNDRAFT VENT SYSTEM

POWER SUPPLY

This downdraft vent must be supplied with 120V, 60Hz., and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse.

Gas Cooktops If this vent is installed in combination with a gas cooktop, it may operate from the same duplex outlet.

Electric Cooktops If this vent is installed in combination with an electric cooktop, the vent must operate from a separate 120V outlet.

A properly grounded 3-prong receptacle should be located within reach of the vent’s 2 foot power cord.

  • Locate the receptacle inside the cabinet on the right side wall. The receptacle cannot be placed on the back of the cabinet wall where it may interfere with the downdraft plenum. See illustration.

Do not leave gas or electrical connections within shaded area.

291⁄2″

Electrical outlet 12″ above cabinet floor

34″ for 36″ models 281⁄2″ for 30″ models

Page 13 of the GE JVB98 user manual — NOTE: Do not exceed 150 foot maximum permissible equivalent lengths!
Page 13 · click to enlarge
Page 13

DUCTWORK LENGTH AND DUCT FITTINGS

NOTE: Do not exceed 150 foot maximum permissible equivalent lengths!

Flexible ducting: If flexible metal ducting is used, all equivalent feet values in the table should be doubled. The flexible metal duct should be straight and smooth and extended as much as possible.

DO NOT use flexible plastic ducting.

Add equivalent lengths for all duct pieces and transitions used to ensure that the duct run does not exceed the maximum 150 feet.

Duct Equivalent Duct Equivalent Duct Equivalent Pieces Length* Pieces Length* Pieces Length*

31⁄4″ x 10″ to 6″ Round 6″ Round 1 ft. (per 31⁄4″ x 10″ Transition 4 ft.

Straight foot length) 45° Elbow 8 ft. 90° Elbow

6″ Round 31⁄4″ x 10″ 1 ft. (per 31⁄4″ x 10″ Wall Cap 24 ft. Straight foot length) 90° Flat Elbow 33 ft. with Damper

6″ Round 31⁄4″ x 10″ 6″ 12 ft. to 31⁄4″ x 10″ 2 ft. Wall Cap 24 ft. 90° Elbow Transition with Damper

31⁄4″ x 10″ 6″ to 6″ Round 2 ft. 6″ Round 45° Elbow 7 ft. Transition Roof Cap 33 ft.

6″ Round to 31⁄4″ x 10″ 31⁄4″ x 10″ Transition 4 ft.

90° Elbow 14 ft. 90° Elbow

SHOULD NOT EXCEED 150 EQUIVALENT FEET *Equivalent lengths of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reflect requirements for good venting performance. See chart for CFM Duct Length.

Page 14 of the GE JVB98 user manual — To Locate the Ductwork Holes in the Cabinet Floor or Side Walls
Page 14 · click to enlarge
Page 14

INSTALLING THE DOWNDRAFT VENT SYSTEM

VENTING OPTIONS

To Change to a Left or Right Discharge

Remove the 4 screws holding the blower

Side-to-Side Adjustments The entire blower mounting plate can be adjusted 31⁄2″ to the left or right. This will help to align vent discharge to house ductwork.

to the mounting plate assembly. Retain screws.

Remove the blower assembly, turn it

over to access the 4 nuts holding the blower to the mounting plate. Remove the nuts.

Loosen screws to adjust blower left to right

Turn the blower to the left or right

discharge direction and reinstall the 4 nuts.

Discharge Direction The blower assembly may be removed and turned 90° for a left or right side discharge.

  • The downdraft vent is shipped with the discharge outlet pointing straight down and can be changed to the left or right side.

Discharge right Discharge left

Reinstall the blower and mounting plate

with original screws.

To Locate the Ductwork Holes in the Cabinet Floor or Side Walls

Temporarily, put vent into the countertop

opening.

Push the vent all the way to the back of

the opening.

  • A left or right 90° direction adjustment should be performed before dropping into the countertop opening.

If you are transitioning to 6″ round,

place transition (obtained locally) over the discharge outlet.

  • Flatten the shipping box to use as a pad.
  • Mark the location and remove the assembly.
  • Lay the vent on its back onto the pad.
  • Cut holes and install ductwork connections.

Order JXRB67 for installation of the blower and motor below the floor.

Order JXBC67 for installation of the blower and motor outdoors.

Discharge down · (as supplied)

Page 15 of the GE JVB98 user manual — B
Page 15 · click to enlarge
Page 15

2 INSTALL THE DOWNDRAFT VENT

INSTALL THE DUCTWORK

Use minimum 26″ gauge galvanized or 24 gauge aluminum duct 3 1⁄4″ x 10″ or 6″ round. PVC duct should be used if installing under a poured concrete slab.

DO NOT USE flexible ducting.

Preferred method Secure the upper brackets with screws located on the side of case and attach to back of cabinet

  • Always use appropriate roof or wall cap with damper. Laundry type wall caps should never be used. See the Ductwork Length and Duct Fittings chart.
  • Use the straightest duct run possible.
  • For satisfactory performance the duct run should not exceed 150 feet or its equivalent length when bends or various fittings are used. Refer to the table of equivalent lengths to calculate your installation.

Secure the lower brackets

Place the downdraft vent into the countertop cutout, against the back side.

Duct tape over seam and screw

A

Secure the downdraft to the countertop

supplied brackets. See illustration.

B

Fasten 2 brackets to vent side and secure

to cabinet back wall.

Install 2 brackets on the bottom of the

  • Install ductwork so the piece of duct nearest the downdraft unit slots INTO the next piece of the duct. Secure the joints with self-tapping screws and apply duct tape around the joints to ensure an airtight seal.

vent. Attach brackets to slide screws on the vent and to the floor using wood screws (not supplied).

When installing in a tile countertop surface, it may be necessary to apply a locally approved caulking to cover any gaps.

to blower housing · Airflow · Screw

Page 16 of the GE JVB98 user manual — D
Page 16 · click to enlarge
Page 16

INSTALLING THE DOWNDRAFT VENT SYSTEM

INSTALL THE RAISE/LOWER SWITCH

E

Remove protective film from the top of the switch trim.

F

Peel film from the adhesive strips on the back of the switch trim. Thread the wire lead through the mounting bracket and countertop. Press trim over the mounting bracket to set the adhesive.

Connect Raise/Lower Wire Lead to Wire Box

A

Thread wire end with the connector through the hole on the end of a wire box. Pull approximately 3″ additional wire length beyond the open end of the box.

B

Connect the mating wire connectors.

Install the wire box onto the bottom of the countertop or directly behind the switch. Use screws or adhesive appropriate for the type of countertop.

D

Place plastic strain relief over the wire, just outside of the hole at the end of the wire box. Do not pinch or twist the wire. Snap the strain relief closed and press into the hole.

Pull 3″ length out of box Control box

A

Drill a 3/8″ hole into the desired location. Use the mounting bracket as a template to locate the hole accurately. Check for interference between the switch cover, adjacent objects and cooktop/vent overlaps.

Connect Wire Lead to Control Box

A

Thread the long 68″ wire lead through the end of the other wire box.

B

Push wire leads into the white connector provided.

B

If switch is mounted into a tile surface, drill the hole between tiles. Use locally approved caulking to cover any gaps.

Push wire connector into the mating connector on the control box. Install the wire box onto the end of the control box with screws provided.

Center the mounting bracket over the hole and mark pilot holes. Remove and drill holes according to type of countertop.

D

Place plastic strain relief over the wire, just outside of the hole at the end in the wire box. Do not pinch or twist the wire. Snap the strain relief closed and press into the hole.

D

Mount the metal switch bracket with screws (not provided). Choose screws for your type of countertop or use locally approved adhesive.

Coil the excess wire and position away from moving parts and cabinet contents. E

Show 6 more labels / short text on this page
Raise/Lower switch · Trim · Mounting bracket · 3/8″ Hole · 2 Pin connector · Strain relief
Page 17 of the GE JVB98 user manual — INSTALL THE COOKTOP
Page 17 · click to enlarge
Page 17

OPTIONAL KITS

CONNECT THE POWER

JXRB67 optional accessory for indoor remote location of the blower/motor assembly. Use this kit when the blower and motor assembly will be located below the cabinet floor.

Plug power cord into a properly grounded receptacle.

INSTALL THE COOKTOP

  • With the downdraft in the “down” position, place the cooktop into the cutout.
  • Push the cooktop back until the back edge of the cooktop just barely touches the front edge of the downdraft cover.
  • Using a dime as a thickness gauge, align the cooktop so that there is a minimum uniform gap of 0.05 ″ (the thickness of a dime) between the cooktop and the downdraft cover.

JXBC67 optional outdoor cover accessory for remote installation of blower and motor assembly on an outside wall.

  • Radiant cooktop cannot be flush mounted when using this downdraft vent.

Mounting brackets

Page 18 of the GE JVB98 user manual — Problem Possible Causes What To Do
Page 18 · click to enlarge
Page 18

Before you call for service…

Operating Instructions Safety Instructions Installation Instructions Troubleshooting Tips Consumer Support

Troubleshooting Tips Save time and money! Review the chart below first and you may not need to call for service.

Problem Possible Causes What To Do

Fan does not work The vent is not fully extended. • Press the Raise/Lower switch.

The blower control switch • Slide it to the right. may be in the OFF position.

Vent does not rise Vent not plugged into an outlet. • Plug vent into a 120V power outlet.

Raise/Lower switch did not • Hold switch down for a couple of seconds to engage lift motor. activate motor.

Circuit breaker may have • Check circuit breaker. Reset if necessary. tripped.

Remote switch not plugged in. • Check all connections between the remote switch and vent body.

Page 19 of the GE JVB98 user manual — Warrantor: General Electric Company. Louisville, KY 40225
Page 19 · click to enlarge
Page 19

GE Downdraft System Warranty.

Consumer Support Operating Instructions Safety Instructions Installation Instructions Troubleshooting Tips

All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, on-line, 24 hours a day, visit us at ge.com, or call 800.GE.CARES (800.432.2737). Please have serial number and model number available when calling for service.

Staple your receipt here. Proof of the original purchase date is needed to obtain service

under the warranty.

For The Period Of: GE Will Replace:

One Year Any part of the downdraft system which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor and in-home original purchase service to replace the defective part.

What GE Will Not Cover:

IService trips to your home to teach you how to use

IDamage to the product caused by accident, fire, floods

the product.

or acts of God.

IImproper installation, delivery or maintenance.

IIncidental or consequential damage caused by possible

defects with this appliance.

IFailure of the product if it is abused, misused,

IDamage caused after delivery.

or used for other than the intended purpose or used commercially.

IProduct not accessible to provide required service.

IReplacement of the replaceable filters.

IReplacement of house fuses or resetting of circuit

breakers.

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service Location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

If you have an installation problem, contact your dealer or installer. You are responsible for providing adequate electrical, gas, exhausting and other connecting facilities as described in the Installation Instructions provided with the product.

Warrantor: General Electric Company. Louisville, KY 40225

Page 20 of the GE JVB98 user manual — Consumer Support
Page 20 · click to enlarge
Page 20

Consumer Support.

GE JVB98 — Consumer Support diagram (page 20)
Fig. 1 · Consumer Support

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts or even schedule service on-line.

GE JVB98 — Consumer Support diagram (page 20)
Fig. 2 · Consumer Support

Expert GE repair service is only one step away from your door. Get on-line and schedule your service at your convenience 24 hours any day of the year! Or call 800.GE.CARES (800.432.2737) during normal business hours.

GE JVB98 — Consumer Support diagram (page 20)
Fig. 3 · Consumer Support

GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).

GE JVB98 — Consumer Support diagram (page 20)
Fig. 4 · Consumer Support

Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime, or call 800.626.2224 during normal business hours. GE Consumer Home Services will still be there after your warranty expires.

GE JVB98 — Consumer Support diagram (page 20)
Fig. 5 · Consumer Support

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.

Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

GE JVB98 — Consumer Support diagram (page 20)
Fig. 6 · Consumer Support

If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations

GE JVB98 — Consumer Support diagram (page 20)
Fig. 7 · Consumer Support

Register your new appliance on-line—at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material.

Printed in the United States

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the GE JVB98

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE JVB98

Be the first to ask — other owners or our team will answer.

Original document

GE JVB98 manual PDF

40 pages·717 KB·Ventilation Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…