Downdraft Vent System


Installation .....................................5–11 Ductwork Table...............................................8 Plan Ductwork.................................................8 Plan Wiring.......................................................9 Install Ductwork...........................................10 Install Wiring.................................................10

Read and save these instructions.
D. Use an extinguisher ONLY if:
1. You know you have Class ABC extinguisher, and you already know how to operate it. 2. The fire is small and contained in the area where it started. 3. The fire department is being called. 4. You can fight the fire with your back to an exit. *Based on “Kitchen Fire Safety Tips” published by NFPA. CAUTION—For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. • Make sure all fingers are away from the downdraft top when it is lowered.
manufacturer. If you have questions, contact the manufacturer. B. Before servicing or cleaning unit, switch power
off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel-burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. This unit must be grounded. WARNING—TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: A. Keep fan, filters and grease laden surfaces clean. B. Always turn hood ON when cooking at high heat. C. Use high range settings on range only when
must be done by qualified persons(s) in accordance with all applicable codes and standards, including fire-rated construction. B. Ducted fans must always be vented to the
outdoors. WARNING—To reduce the risk of fire, use only metal ductwork. Important—Save for the local electrical inspector’s use.
necessary. Heat oil slowly on low to medium setting. D. Don’t leave range unattended when cooking. E. Always use cookware and utensils appropriate
for the type and amount of food being prepared. WARNING—TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*: A. SMOTHER FLAMES with a close-fitting lid,
If You Need Service...
cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. B. NEVER PICK UP A FLAMING PAN—
You may be burned. C. DO NOT USE WATER, including wet dishcloths
or towels — a violent steam explosion will result.

Safety Instructions Servicing Using Vent System Cooking Tips
Disconnect power to the cooktop and remove it first. Reverse the steps in the Install the Downdraft section to remove the downdraft from the cabinet. Service parts are available from your local GE distributor or from a GE Service and Parts Center.
Turn the downdraft blower ON by pressing down on the activating switch. The air vent will rise.
Turn the downdraft blower OFF by pressing the activating switch again. The air vent will go down and the blower will shut off.
The blower can be ON or OFF and its speed can be adjusted with the recessed knob on the right side of the air vent.
When canning foods in a water-bath canner, a gentle but steady boil must be maintained continuously for the required time. When canning foods in a pressure canner, the pressure must be maintained continuously for the required time. Use of the blower at a high speed when canning may reduce the temperature enough to stop boiling. While canning, we recommend using the downdraft at LOW speed and using the front surface unit.
Knob

The efficiency of your downdraft depends on a clean filter. Frequency of cleaning depends on the type of cooking you do. Grease filters should be cleaned at least once a month. Never operate the downdraft without the filters in place. To remove: Pull the filters out by grasping them and pulling straight up. To clean: Soak and then agitate in a hot detergent solution. Light brushing may be used to remove imbedded soil. Rinse, shake and remove moisture before replacing. With careful handling, the filter will last for years. If replacement becomes necessary, order the part from your dealer.

Clean greasy surfaces frequently, using a mild detergent. Do not use abrasive cloth, steel wool pads or scouring powder because they will mar the surface.
Clean with warm sudsy water, a stainless steel cleaner such as Kleen King®, or an all-purpose liquid or spray cleaner. Always scrub in the direction of the grain. Rinse thoroughly with a sponge or cloth and clean water. Dry with a soft, clean cloth. Do not use a soap-filled steel wool pad; it will scratch the surface.


If you need more help…call toll free: GE Answer Center® 800.626.2000 consumer information service

Before Starting Installation Check the Following Requirements This downdraft blower system is designed to be used to exhaust smoke and odors when cooking with all GE electric and sealed burner gas cooktops (not approved for standard burner gas cooktops). It can be mounted in either an island or peninsula location.
Minimum 26″ Cabinet depth required
A countertop with a raised lip may not allow enough flat countertop for a proper installation. Before starting installation review the following pages carefully. Cutout dimension and illustrations are given for 30″ and 36″ cooktops.





Plan the Ductwork
Steps to Determine Flexible Ducting’s Equivalent Length 1. Measure the actual amount of offset (Maximum 3″ recommended). The effect upon airflow is dependent upon the amount of offset. 2. Calculate the equivalent ducting allowances using:
( ___ in. offset) x (14 Ft. per inch) = ___ Ft. equivalent length. 3. Ensure that the total equivalent length of ducting does not exceed the maximum recommendation of 100 feet.
Down discharge (as shipped)
1. This downdraft blower system is designed for use with 31⁄4″ x 10″ ductwork (can be transitioned to 6″ round). Three different discharge directions are available with side--to-side adjustment for accurate alignment of ductwork. 2. For best performance: Choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions. Check location of floor joists, wall joists, wall studs, electrical wiring or plumbing for possible interference. NOTE: The unit is shipped with the 31⁄4″ x 10″ discharge facing DOWN. See the Changing Blower Direction section, if necessary.
Venting Island to Outside Wall
24″ Power Cord provided (on-right-hand side)
291/2″

Plan the Wiring 1. The downdraft blower system draws 4 AMPS and requires a 120 VAC, 60 Hz circuit. 2. The unit has a 2 ft. long power cord with a 3-pronged plug. Plan to provide a grounded outlet in a location which will allow the unit’s power cord to reach. The outlet cannot be located on a back wall. The outlet needs to be mounted on the side wall of the cabinet or it could be on the back wall of an adjacent cabinet with access through an opening in the side wall. (Based on local codes.)
1. Remove the 4 nuts and 2 clamp channels. 2. Loosen the screws holding the gear motor cover and slide it away from the blower. 3. Carefully lift the blower and disconnect the motor plug if necessary. Reposition the blower and reconnect the motor plug. 4. Use the supplied cover plate to close any open space. 5. Replace the clamp channels and use the nuts to secure the blower in its new position. 6. Reposition the gear motor covers and tighten the screws. 7. Use sheet metal screws through the bottom flange to secure the bottom of the blower.
Clamp channel Bottom flange

Install the Downdraft
Install the Ductwork CAUTION- BEFORE CUTTING A HOLE IN CABINET FOR DUCTWORK: Check for interference with floor joists, wall studs, electrical wiring or plumbing.
Leveling bracket– flange facing out
31⁄4″ x 10″ to 6″ RD. Transition
Leveling bracket– flange facing in
6″ RD. Elbow & ductwork
1. Set the downdraft into the opening. Extend the leveling brackets to the floor of the cabinet so the downdraft sits straight. (NOTE: Leveling brackets can be removed and re-attached in other positions. The bottom flange may have to face inward in tight cabinet installations.) 2. Secure the downdraft to the countertop as follows: Hold the downdraft against the back of the countertop cut-out and tighten the 2 mounting screws (one on each end of unit) on the underside of the countertop. Use a wood shim between the screw and the underside of granite countertops. 3. Screw the leveling brackets to the bottom of the cabinet. Tighten the screws holding the leveling bracket to the unit on each side.
1. Cut the hole in the cabinet as well as holes in the wall or floor as necessary. 2. Mount the roof or wall cap and work back towards the cabinet, attaching all ductwork, elbows and transitions as previously planned. Tape all ductwork connections to make them secure and air tight. 3. Connect the ductwork (and transition, if required) to the downdraft. If necessary, LOOSEN wing nuts and screws that hold the blower in place, and slide the blower left or right to meet the ductwork. Re-tighten the screws and wing nuts. NOTE: A 31⁄4″ x 10″ collar is provided for installers who prefer to rivet the cutwork to the unit. This will allow the blower to be removed and replaced easily in service situations without disturbing the ductwork.
Install the Electrical Wiring 1. Mount a standard wiring box, with 3-pronged outlet, inside the cabinet. Make sure the downdraft’s power cord can easily reach it. 2. Run the appropriate power cable into the cabinet and connect it to the outlet. 3. Plug the downdraft’s power cord into the outlet.

Install the Cooktop 1. Align the cooktop with the downdraft and fasten cooktop in place. NOTE: Accurate alignment of cooktop and downdraft is necessary to ensure that there is not interference when air vent is raised and lowered. There should be a gap of 1/32″–1/16″ between the back of the cooktop and the front of the downdraft cover.
Adjust the Switch The downdraft is factory-adjusted for proper operation. However, shipping and handling may affect the positions of the activating switch. To adjust position of activating switch:

YOUR DOWNDRAFT SYSTEM
WARRANTY
is needed to obtain service
under warranty.
WHAT IS COVERED FULL ONE-YEAR WARRANTY For one year from date of original purchase, we will provide, free of charge, parts and service labor in your home to repair or replace any part of the downdraft system that fails because of a manufacturing defect.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for ordinary home use in the 48 mainland states, Hawaii and Washington, D.C. In Alaska the warranty is the same except that it is LIMITED because you must pay to ship the product to the service shop or for the service technician’s travel costs to your home. All warranty service will be provided by our Factory Service Centers or by our authorized Customer Care® servicers during normal working hours. Should your appliance need service, during warranty period or beyond, call 800-GE-CARES (800-432-2737).
WHAT IS NOT COVERED • Service trips to your home to teach you how to use the product. Read your Use and Care material. If you then have any questions about operating the product, please contact your dealer or our Consumer Affairs office at the address below, or call, toll free: GE Answer Center® 800.626.2000 consumer information service
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
To know what your legal rights are in your state, consult your local or state consumer affairs office or your state’s Attorney General.
If further help is needed concerning this warranty, write: Manager—Consumer Affairs, GE Appliances, Louisville, KY 40225
JVB64 JVB65 JVB96 Part No. 164D3333P139 Pub No. 49-8904 99 04 2007B
3-98 CG
Printed in the United States
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| FAN DOES NOT WORK | • The vent must be fully extended before the downdraft will work. • The blower control knob must be turned in a clockwise direction to turn the blower on. | p.4 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.