GE Operator Interface Terminal (HE500TIU110)

43 pages·563 KB·Cell Phone·PDF·ENDEFRITNLJA
GE Operator Interface Terminal (HE500TIU110)
Table of Contents 72 sections Hardware Manual for the · HE500TIU050 HE500TIU100 · IC300TIU101 HE500TIU102 HE500TIU103 HE500TIU110 · IC300TIU111 HE500TIU112 HE500TIU113 HE500TIU200 · … ShowHide
Page 1 of the GE Operator Interface Terminal (HE500TIU110) user manual — 06 April 2000 GFK-1819
Page 1 · click to enlarge
Page 1

Hardware Manual for the

HE500TIU050 HE500TIU100

IC300TIU101 HE500TIU102 HE500TIU103 HE500TIU110

IC300TIU111 HE500TIU112 HE500TIU113 HE500TIU200

IC300TIU201 HE500TIU202 HE500TIU203 And SmartStack Modules

Operator Station Hardware Manual

06 April 2000 GFK-1819

Page 2 of the GE Operator Interface Terminal (HE500TIU110) user manual — Note
Page 2 · click to enlarge
Page 2

PREFACE 06 Apr 2000 PAGE 3

Warnings, Cautions, and Notes as Used in this Publication

Warning

In situations where inattention could cause either personal injury or damage to equipment, a Warning notice is used.

Caution

Note

This document is based on information available at the time of its publication. While efforts have been made to be accurate, the information contained herein does not purport to cover all details or variations in hardware or software, nor to provide for every possible contingency in connection with installation, operation, or maintenance. Features may be described herein which are not present in all hardware and software systems. GE Fanuc Automation assumes no obligation of notice to holders of this document with respect to changes subsequently made.

GE Fanuc Automation makes no representations or warranty, expressed, implied, or statutory with respect to, and assumes no responsibility for the accuracy, completeness, sufficiency, or usefulness of the information contained herein. No warranties of merchantability or fitness for purpose shall apply.

The following are trademarks of GE Fanuc Automation North America, Inc.

Alarm Master CIMSTAR Helpmate PROMACRO Series Six CIMPLICITY GEnet Logicmaster Series One Series 90 CIMPLICITY 90 – ADS Genius ModelMaster Series Three VuMaster CIMPLICITY Power TRAC Genius PowerTRAC ProLoop Series Five Workmaster

The following are trademarks of Horner Electric, APG, LLC.

Copyright 2000 GE Fanuc Automation North America, Inc.

Cscape SmartStack CsCAN · All Rights Reserved

Page 3 of the GE Operator Interface Terminal (HE500TIU110) user manual — DECLARATION OF EMC CONFORMITY
Page 3 · click to enlarge
Page 3

PAGE 4 06 Apr 2000 PREFACE GFK-1819

ABOUT PROGRAMMING EXAMPLES

Any example programs and program segments in this manual or provided on accompanying diskettes are included solely for illustrative purposes. Due to the many variables and requirements associated with any particular installation, GE Fanuc cannot assume responsibility or liability for actual use based on the examples and diagrams. It is the sole responsibility of the system designer utilising the Operator Station to appropriately design the end system, to appropriately integrate the Operator Station and to make safety provisions for the end equipment as is usual and customary in industrial applications as defined in any codes or standards which apply.

DECLARATION OF EMC CONFORMITY

Manufacturer's NameHorner Ireland Ltd. Manufacturer's Address: Unit 1, Centrepoint, Centre Park Road, Cork, Ireland

Declares that the products Models: HE500TIU050, HE500TIU100, IC300TIU101, HE500TIU102, HE500TIU110, IC300TIU111, HE500TIU200, IC300TIU201 and HE500TIU202. Conforms to the following EMC standards:

EMCEN 55 022, Radiated and Conducted Emissions EN 50 082-1, RF, EFT/EFB, ESD Immunity

Supplementary Information:

The above conformity only relates to the products in a stand-alone capacity. The products are used as part of a system and are therefore classified as a component. As a component, the products are prohibited by EC regulations to carry a CE Mark for EMC conformity. Static discharge tests only apply to normal operation of the keyboards via the front panel. We would stress that the use of our products within your system, while helping to ensure compliance of your system to the same directives, do not necessarily guarantee that compliance will be achieved. We would also like to point out that the interpretation of the law concerning CE marking and its application to sub-assemblies and components is open to interpretation.

Date31 Mar 1999
Page 4 of the GE Operator Interface Terminal (HE500TIU110) user manual — ABOUT PROGRAMMING EXAMPLES
Page 4 · click to enlarge
Page 4
Page 4 of the GE Operator Interface Terminal (HE500TIU110) user manual — ABOUT PROGRAMMING EXAMPLES
Page 5 of the GE Operator Interface Terminal (HE500TIU110) user manual — ABOUT PROGRAMMING EXAMPLES
Page 5 · click to enlarge
Page 5

PAGE 6 06 Apr 2000 PREFACE GFK-1819

7.1.2 Display Test 35 7.1.3 Keyboard Test 35 7.1.4 RAM Test 35 7.1.5 Serial Loop-back Tests 35 7.2 Updating the Protocol 36 7.3 Updating the Operating System 36 CHAPTER 8 : NETWORKS 37

8.1 Scope 37 8.2 Controller Area Network (CAN) Overview 37 8.2.1 CAN Features 37 8.3 CsCAN Network Overview 37 8.3.1 CsCAN Network Features 37 8.3.2 CsCAN Network Operation 37 8.4 DeviceNet Overview 38 8.4.1 DeviceNet Features 38 8.4.2 DeviceNet Protocol 39 8.4.3 DeviceNet Operation 39 8.5 CAN Wiring Rules 40 8.6 Profibus 41 8.6.1 Profibus Wiring 41 CHAPTER 9: SMARTSTACK 43

9.1 Scope 43 9.2 Installing and Removing a SmartStack Module 43 9.2.1 Installing SmartStack Modules 43 9.2.2 Removing SmartStack Modules 43

Page 6 of the GE Operator Interface Terminal (HE500TIU110) user manual — HE500TIU112-02
Page 6 · click to enlarge
Page 6
CH.1INTRODUCTION 06 Apr 2000 PAGE 7

CHAPTER 1: INTRODUCTION

1.1 Scope The Operator Station (TIU050/10X/11X/20X) is an Operator Station (OS) that provides extensive monitoring and control in an extremely small package. The Operator Station “OS” product line offers four distinct categories of products as described in Table 1.1.

Table 1.1 – Operator Station (OS) Product Line Note: Only IC300 TIU101 / IC300 TIU111 IC300 TIU201 models are available through GE Fanuc Channels. ModelDescription TIU050: Text Only HE500TIU050-001 HE500TIU050-0022 lines x 20 characters. 2 lines x 20 characters with Real Time Clock. TIU10x: Text / Semi-Graphics HE500TIU100-01 HE500TIU100-02 HE500TIU100-03 HE500TIU100-04 HE500TIU100-05 HE500TIU100-06 HE500TIU100-07 HE500TIU100-098 Lines x 20 Characters plus 128 x 64 pixels. 8 Lines x 20 Characters plus 128 x 64 pixels with Real Time Clock. 8 Lines x 20 Characters plus 128 x 64 pixels with Current Loop. 8 Lines x 20 Characters plus 128 x 64 pixels with Current Loop and Real Time Clock. 8 Lines x 20 Characters plus 128 x 64 pixels with Stud Type Metalwork 8 Lines x 20 Characters plus 128 x 64 pixels with wide temperature display. 8 Lines x 20 Characters plus 128 x 64 pixels with Bezel 8 Lines x 20 Characters plus 128 x 64 pixels with no metal and dill connectors IC300TIU101-01 IC300TIU101-028 Lines x 20 Characters plus 128 x 64 pixels with CsCAN Network. 8 Lines x 20 Characters plus 128 x 64 pixels with CsCAN Network and Real Time Clock. HE500TIU102-01 HE500TIU102-028 Lines x 20 Characters plus 128 x 64 pixels with a Profibus Network. 8 Lines x 20 Characters plus 128 x 64 pixels with Profibus Network and Real Time Clock. HE500TIU103-01 HE500TIU103-028 Lines x 20 Characters plus 128 x 64 pixels with DeviceNet Networks. 8 Lines x 20 Characters plus 128 x 64 pixels with DeviceNet Networks and Real Time Clock. TIU11X: Text / Semi Graphics with Numeric Keypad HE500TIU110-01 HE500TIU110-02 HE500TIU110-03 HE500TIU110-04 HE500TIU110-05 HE500TIU110-06 HE500TIU110-07 HE500TIU110-098 Lines x 20 Characters plus 128 x 64 pixels plus a Numeric keypad. 8 Lines x 20 Characters plus 128 x 64 pixels plus a Numeric keypad with Real Time Clock. 8 Lines x 20 Characters plus 128 x 64 pixels plus a Numeric keypad with Current Loop. 8 Lines x 20 Characters plus 128 x 64 pixels plus a Numeric keypad with Current Loop and Real Time Clock. 8 Lines x 20 Characters plus 128 x 64 pixels with Stud Type Metalwork. 8 Lines x 20 Characters plus 128 x 64 pixels with wide temperature display. 8 Lines x 20 Characters plus 128 x 64 pixels with Bezel 8 Lines x 20 Characters plus 128 x 64 pixels with no metal and dill connectors IC300TIU111-01 IC300TIU111-028 Lines x 20 Characters plus 128 x 64 pixels plus a Numeric keypad with CsCAN Network. 8 Lines x 20 Characters plus 128 x 64 pixels plus a Numeric keypad with CsCAN Network and Real Time Clock.

HE500TIU112-02

Page 7 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 1: INTRODUCTION
Page 7 · click to enlarge
Page 7

PAGE 8 06 Apr 2000 CH. 1: INTRODUCTION GFK-1819

HE500TIU113-01 HE500TIU113-028 Lines x 20 Characters plus 128 x 64 pixels with DeviceNet Network. 8 Lines x 20 Characters plus 128 x 64 pixels with DeviceNet Network and Real Time Clock. TIU20X: Text / Full Graphics with Numeric / Function Keypad HE500TIU20016 Lines x 40 Characters plus 240 x 128 pixels plus a Numeric keypad / Function keypad. Optional SmartStack I/O. IC300TIU20116 Lines x 40 Characters plus 240 x 128 pixels plus a Numeric keypad / Function keypad. Optional SmartStack I/O. Can be used with CsCAN Network. HE500TIU20216 Lines x 40 Characters plus 240 x 128 pixels plus a Numeric keypad / Function keypad. Optional SmartStack I/O. Can be used in a Profibus Network. HE500TIU20316 Lines x 40 Characters plus 240 x 128 pixels plus a Numeric keypad / Function keypad. Optional SmartStack I/O. Can be used with DeviceNet Network.

The front panel of the OS has a bright and clear display (LCD with adjustable back lit) and easy-to-use push buttons. On the back panel are communication ports for connection to automation equipment (programmable logic controller, drive, weighing equipment or other equipment) and a PC (IBM or compatible computer). Also located on the back panel or end of the back panel depending on the model, the OS has clearly displayed features such as power input, PC and PLC port, Tx and Rx LEDs. Also, depending on the model, a network port is provided for connection to whichever OS network you have chosen.

The OS supports a variety of protocols. Various protocols can be downloaded through the PC port and stored in the unit’s flash memory. The operating system can also be downloaded through the PC port.

The OS range supports 3 network options. CsCAN (TIUXX1) and Device (TIUXX3) and Profibus with the TIUXX2 range.

HE500TIU050HE500TIU10XHE500TIU11XHE500TIU20X Software CbreezeIncludedIncludedIncludedIncluded Programming Port RS232StandardStandardStandardStandard Communication Port 232/4851111 Flash Ram64 K Words256 K Words256 K Words512 K Words Memory UpgradeNoNoNo1 Meg Words SRam32 K Bytes128 K Bytes128 K Bytes128 K Bytes Memory UpgradeNoNoNo512 K Bytes Total Pages300300300300 Characters per Page2x208x208x2016x40 Graphics pixelsText Only128 x 64128 x 64240 x 128 Data fields/page88824 No. of Text tables249249249249 Text table size Rows & ColumnsNoNoNo256 Recipe Memory064K64K64K RecipesNoStandardStandardStandard Editable FontsNoStandardStandardStandard Scaling Range checkingStandardStandardStandardStandard TendingNoStandardStandardStandard GraphingNoStandardStandardStandard Editable GraphicsNoNoNoStandard
Page 8 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 1: INTRODUCTION
Page 8 · click to enlarge
Page 8
CH.1INTRODUCTION 06 Apr 2000 PAGE 9
Animated BitmapsNoNoNoStandard Alarms and Status pagesStandardStandardStandardStandard Numeric keysStandardNoStandardStandard System keys4444 Function keys *10No1218 LED'sNoNoNo10 SmartStack optionNoNoNoStandard Battery Back Ram + Real Time ClockOptionalOptionalOptionalStandard Comprehensive Math's FacilitiesNo1024 lines1024 lines1024 lines Day & Time Scheduling, Background TaskNoStandardStandardStandard Internal RegistersNo1024 %R1024 %R1024 %R Operating Temperature C°0 to 500 to 500 to 500 to 50 Storage Temperature C°-10 to 70-10 to 70-10 to 70-10 to 70 Humidity Non Condensing Storage10-90%10-90%10-90%10-90% Environmental NEMA4 / IP65YesYesYesYes Y2K Certified CE ApprovedYesYesYesYes Size -Width ,Height ,Depth mm180 X 120 X 60121 X 105 X 38172 X 105 X 38281 X 192 X 58 Cut-out -- Width , Height mm151 X 89100 X 85153 X 85242 X 158 Screen dimensions mm80 X 1770 X 3870 X 38130 X 75 Input Voltage Range9-35 Vdc9-35 Vdc9-35 Vdc9-35 Vdc Weight (grams)3253704501855 NetworkDeviceNet, CsCANNoOptionalOptionalOptional Data xfer from Automated device via network - ProfibusNoOptionalOptionalOptional

* System keys can be programmed to be function keys at specific times in the project. See Function keys in CBREEZE Software Manual MAN0023

** The TIU100/110 is available with two non-standard features: 20mA current loop communication and a real-time clock (RTC). Both can be ordered at the time of purchase. The current loop can be re-fit by the user later. The RTC requires factor re-fit. The TIU050 is only available with the real-time clock option.

*** The TIU20X provides for the display of both text and full graphics and has a Numeric/Function Keypad. It also allows the use of a wide range of SmartStack I/O options.

1.2 Equipment Needed 1. The current version of CBREEZE software install on a PC running Windows 95, Windows 98 or Windows NT. 2. TIU050/10X/11X/20X Interface Unit.

Page 9 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 1: INTRODUCTION
Page 9 · click to enlarge
Page 9

PAGE 10 06 Apr 2000 CH. 1: INTRODUCTION GFK-1819

3. PC to TIU Programming Cable HE693CBL232 or equivalent See Chapter on Communications
Page 10 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 1: INTRODUCTION
Page 10 · click to enlarge
Page 10
CH.1INTRODUCTION 06 Apr 2000 PAGE 11
Table 1.2 – Technical Specifications ParameterConditionsMin.TypicalMax.Units Input voltage (V) I102432VDC Typical power consumption TIU050 TIU10X TIU11X TIU20XV = 24VDC I V = 24VDC I V = 24VDC I V = 24VDC I130 130 130 350mA Inrush input currentV = 24VDC for 4ms I260mA Operating temperature TIU050 TIU10X TIU10X-6 TIU11X TIU11X-6 TIU20XA TIU20XB or higher0 0 -10 0 -10 0 050 50 60 50 60 45 50°C Storage temperature-2070°C Relative Humidity(non-condensing)1090% Weight TIU050 TIU10X TIU11X TIU20X320 370 470 1870350 400 500 1900g Dimensions TIU050 TIU10X TIU11X TIU20X179 x 111 x 60 121 x 105 x 38 172 x 105 x 38 282 x 194 x 62mm Cable Lengths † RS-232 RS-485115 1500m IP ratingNEMA 4-12/IP65 EMC ConformanceEN 55 022, Radiated and Conducted Emissions EN 61000-4-3, Radiated and Conducted RF Immunity ENV 50144 † Cables beyond the maximum recommended length may create communication problems. Both ends of an RS-485 network must be properly terminated at 120Ω and grounded.
Page 11 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 1: INTRODUCTION
Page 11 · click to enlarge
Page 11

PAGE 12 06 Apr 2000 CH. 1: INTRODUCTION GFK-1819

1.4 Upgrade Revision Software & Firmware

1.4.1 Scope To avail of any new features that are included in this new release on units that were purchased previous to this release, both software and firmware require updating by the user. Any new unit will be set-up for the latest version released.

1.4.2 Software Upgrade To update the software requires that the user install the new version of software from the installation CD. You may install the new software over any previous version installed. See section 1.4 Software Installation Instructions. To update existing projects simple open the project from the newly installed version of the software. Once the project is saved to disk the update is complete. For backup reasons we recommend that you save the new version of your project in a different location or under a different file name.

1.4.3 Firmware Upgrade The following steps assume that a project or configuration is loaded to the Operator Station and that the user is running the latest version of software.

a) Upload the project/configuration from the unit. b) If a customised character set is loaded to the unit then upload the character set also. c) Choose Automation Device from main menu Configure/Communication Settings. d) From File menu choose Update TIU Operating System. (See Updating Operating System for more

details). e) From File menu choose Update TIU Protocol. If you are updating from firmware version 2.00 or later

then you just have to update to the latest protocol file. However if you are updating from firmware version 1.24 or earlier you most update to a Upgrade.1xx protocol file first, then update to the latest firmware revision. See Note. (See updating protocol for further information). f) Choose Download Character Sets to TIU from File menu. g) Choose Download Project to TIU from File menu.

Page 12 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 1: INTRODUCTION
Page 12 · click to enlarge
Page 12
CH.1INTRODUCTION 06 Apr 2000 PAGE 13
Page 13 of the GE Operator Interface Terminal (HE500TIU110) user manual — NOTES
Page 13 · click to enlarge
Page 13

PAGE 14 06 Apr 2000 CH. 1: INTRODUCTION GFK-1819

NOTES

Page 14 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 2: TIU050
Page 14 · click to enlarge
Page 14
CH.2TIU050 06 Apr 2000 PAGE 15

CHAPTER 2: TIU050

2.1 Scope The TIU050 is a 2 line text only display terminal. The hardware description is detailed in this chapter.

GE Operator Interface Terminal (HE500TIU110) — CHAPTER 2: TIU050 diagram (page 14)
Fig. 1

2 AB C 3 DE F 4 GH I 5 JKL F2 F3 F4 F5

2.2 TIU050 Button Selection Actions a) PAUSE key selects data for editing OR exits from data editing. b) PAUSE & DOWN keys pressed together, enters sub menu pages. c) PAUSE & UP keys pressed together, exits sub menus to the parent menu pages. d) UP key selects the previous menu page, sub menu page, alarms, and increments data e) DOWN key selects the next menu page, sub menu page, alarms and also decrements data. f) ENTER key sends data to the automation equipment, accepts alarms, and displays accepted alarms. g) ALPHANUMERIC KEYPAD and FUNCTION KEYS can be used to enter data or can be used to

preform some pre-programmed action.

2.3 TIU050 Contrast Adjustment On menu page 1 (after the start-up screen), hold the ENTER key and press the UP or DOWN key to adjust the contrast. The contrast setting is stored and not lost after removing power.

CONTRAST BAND - allows the user to set the lower and upper limits of contrast. Adjust the lower limit using the UP or DOWN key and press Enter when done. Do the same for the upper limit. WARNING: - Changes to the lower or upper limits may allow the user to set the contrast to a setting where the display may appear blank. It is recommended that the factory setting are used (Min 8A, Max FE).

Page 15 of the GE Operator Interface Terminal (HE500TIU110) user manual — OFF
Page 15 · click to enlarge
Page 15

PAGE 16 06 Apr 2000 CH. 2: TIU050 GFK-1819

2.4 TIU050 Ports

GE Operator Interface Terminal (HE500TIU110) — OFF diagram (page 15)
Fig. 2

2.4.1 TIU050 Configuration of the RS-485 Port

GE Operator Interface Terminal (HE500TIU110) — OFF diagram (page 15)
Fig. 3

OFF

ON

SW 1

Figure 2.3 – Power Connector Powered by +24VDC and Ground.

Figure 2.4 – Configuration Bank

The configuration bank (shown in Figure 2.5) sets the parameters of the RS-485 port as described in Table 2.1.

GE Operator Interface Terminal (HE500TIU110) — OFF diagram (page 15)
Fig. 4

Table 2.1 – Configuration Bank Switch 1 ON: Pull-up (must be used together with switch 3) OFF: no Pull-up Switch 2 ON: 120Ω termination OFF: no termination Switch 3 ON: Pull-down (must be used together with switch 1) OFF: no Pull-down Switch 4 Reserved for future use NOTE: Switch 1 and 3 must be used together. Either both pull-up and pull-down are used or neither is used.

Page 16 of the GE Operator Interface Terminal (HE500TIU110) user manual — TIU050 CUTOUT DETAILS
Page 16 · click to enlarge
Page 16
CH.2TIU050 06 Apr 2000 PAGE 17

Pull-up and Pull-down switches are used to increase the signal level on the RS-485 bus. This is useful if there is a long bus and a significant amount of attenuation is anticipated.

Termination resistance of 120Ω must be placed across each end of the RS-485 bus. With switch 2 ON, a 120Ω resistance is placed across the bus. This is only used if the TIU050/100/110 is the last device at either end of the bus.

2.5 TIU050 Dimensions

5.95” [151mm]

3.27” [83 mm] +0.02 -0.00

+0.5 -0.0

UP TO 0.04”[1mm] CORNER RADIUS IS ACCEPTABLE

TIU050 CUTOUT DETAILS

TOLERANCES ARE +/- 0.01” [0.3mm] UNLESS STATED OTHERWISE

Figure 2.5 – TIU050 Cutout

Page 17 of the GE Operator Interface Terminal (HE500TIU110) user manual — NOTES
Page 17 · click to enlarge
Page 17

PAGE 18 06 Apr 2000 CH. 2: TIU050 GFK-1819

NOTES

Page 18 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 3: TIU100/101/102/103
Page 18 · click to enlarge
Page 18
CH. 3TIU100/101/102/103 06 Apr 2000 PAGE 19

CHAPTER 3: TIU100/101/102/103

3.1 Scope The TIU10X 128 x 64 pixel display, which allows for some graphics and various fonts to be displayed. . The hardware description is detailed in this chapter.

GE Operator Interface Terminal (HE500TIU110) — CHAPTER 3: TIU100/101/102/103 diagram (page 18)
Fig. 5

3.2 TIU10X Button Selection Actions a) PAUSE key selects data for editing OR exits from data editing. b) PAUSE & DOWN keys pressed together, enters sub menu pages. c) PAUSE & UP keys pressed together, exits sub menus to the parent menu pages. d) UP key selects the previous menu page, sub menu page, alarms, and increments data e) DOWN key selects the next menu page, sub menu page, alarms and also decrements data. f) ENTER key sends data to the automation equipment, accepts alarms, and displays accepted alarms.

3.3 TIU10X Contrast Adjustment On menu page 1 (after the start-up screen), hold the ENTER key and press the UP or DOWN key to adjust the contrast. The contrast setting is stored and not lost after removing power.

CONTRAST BAND - allows the user to set the lower and upper limits of contrast. Adjust the lower limit using the UP or DOWN key and press Enter when done. Do the same for the upper limit. WARNING: - Changes to the lower or upper limits may allow the user to set the contrast to a setting where the display may appear blank. It is recommended that the factory setting are used (Min 8A, Max FE).

Page 19 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 3: TIU100/101/102/103
Page 19 · click to enlarge
Page 19

PAGE 20 06 Apr 2000 CH.3: TIU100/101/102/103 GFK-1819

3.4 TIUX Rear View

GE Operator Interface Terminal (HE500TIU110) — CHAPTER 3: TIU100/101/102/103 diagram (page 19)
Fig. 6

3.5 TIU100 Ports

GE Operator Interface Terminal (HE500TIU110) — CHAPTER 3: TIU100/101/102/103 diagram (page 19)
Fig. 7
Page 20 of the GE Operator Interface Terminal (HE500TIU110) user manual — Rx
Page 20 · click to enlarge
Page 20
CH. 3TIU100/101/102/103 06 Apr 2000 PAGE 21

Rx

Rx

Tx

Tx

Serial Port

PC Port

Figure 3.4 – Automation Equipment Port Receive &

Figure 3.5 – PC Port Receive &

Transmit LEDs The LED’s flash when the PC is communicating with the TIU10X

Transmit LEDs The LED’s flash when the TIU10X

is communicating with the AE.

Figure 3.3 – Automation Equipment Serial Port

3.5.1 TIU10X Configuration of the RS-485 Port The configuration bank (shown in Figure 3.8) sets the parameters of the RS-485 port as described in Table 3.1.

Table 3.1 – Configuration Bank Switch 1 ON: Pull-up (must be used together with switch 3) OFF: no Pull-up Switch 2 ON: 120Ω termination OFF: no termination Switch 3 ON: Pull-down (must be used together with switch 1) OFF: no Pull-down Switch 4 Reserved for future use NOTE: Switch 1 and 3 must be used together. Either both pull-up and pull-down are used or neither is used.

Pull-up and Pull-down switches are used to increase the signal level on the RS-485 bus. This is useful if there is a long bus and a significant amount of attenuation is anticipated.

Page 21 of the GE Operator Interface Terminal (HE500TIU110) user manual — TIU10X CUTOUT DETAILS
Page 21 · click to enlarge
Page 21

PAGE 22 06 Apr 2000 CH.3: TIU100/101/102/103 GFK-1819

GE Operator Interface Terminal (HE500TIU110) — TIU10X CUTOUT DETAILS diagram (page 21)
Fig. 8

Figure 3.6 – Power Connector Powered by +24VDC and Ground.

Termination resistance of 120Ω must be placed across each end of the RS-485 bus. With switch 2 ON, a 120Ω resistance is placed across the bus. This should only be used if the TIU050/100/110 is the last device at either end of the bus.

3.6 TIU10X Dimensions

GE Operator Interface Terminal (HE500TIU110) — TIU10X CUTOUT DETAILS diagram (page 21)
Fig. 9

3.27” [83 mm] + 0.02 -0.00

+ 0.5 -0.0

TIU10X CUTOUT DETAILS

TOLERANCES ARE +/- 0.01” [0.3mm] UNLESS STATED OTHERWISE

Figure 3.8 – TIU10X Cutout

Page 22 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 4: TIU110/111/112/113
Page 22 · click to enlarge
Page 22
CH. 4TIU110/111/112/113 06 Apr 2000 PAGE 23

CHAPTER 4: TIU110/111/112/113

4.1 Scope The TIU11X 128 x 64 pixel display, which allows for some graphics and various fonts to be displayed. The hardware description is detailed in this chapter.

GE Operator Interface Terminal (HE500TIU110) — CHAPTER 4: TIU110/111/112/113 diagram (page 22)
Fig. 10

Figure 4.1 – Front View of TIU110

4.2 TIU11X Button Selection Actions a) PAUSE key selects data for editing OR exits from data editing. b) PAUSE & DOWN keys pressed together, enters sub menu pages. c) PAUSE & UP keys pressed together, exits sub menus to the parent menu pages. d) UP key selects the previous menu page, sub menu page, alarms, and increments data e) DOWN key selects the next menu page, sub menu page, alarms and also decrements data. f) ENTER key sends data to the automation equipment, accepts alarms, and displays accepted alarms. g) ALPHANUMERIC KEYPAD and PROGRAMMABLE KEYS can be used to enter data or can be

used to preform some pre-programmed action.

4.3 TIU11X Contrast Adjustment On menu page 1 (after the start-up screen), hold the ENTER key and press the UP or DOWN key to adjust the contrast. The contrast setting is stored and not lost after removing power.

CONTRAST BAND - allows the user to set the lower and upper limits of contrast. Adjust the lower limit using the UP or DOWN key and press Enter when done. Do the same for the upper limit. WARNING: - Changes to the lower or upper limits may allow the user to set the contrast to a setting where the display may appear blank. It is recommended that the factory setting are used (Min 8A, Max FE).

Page 23 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 4: TIU110/111/112/113
Page 23 · click to enlarge
Page 23

PAGE 24 06 Apr 2000 CH. 4: TIU110/111/112/113 GFK-1819

4.4 TIU11X Rear View

GE Operator Interface Terminal (HE500TIU110) — CHAPTER 4: TIU110/111/112/113 diagram (page 23)
Fig. 11

4.5 TIU110 Ports

GE Operator Interface Terminal (HE500TIU110) — CHAPTER 4: TIU110/111/112/113 diagram (page 23)
Fig. 12
Page 24 of the GE Operator Interface Terminal (HE500TIU110) user manual — OFF
Page 24 · click to enlarge
Page 24
CH. 4TIU110/111/112/113 06 Apr 2000 PAGE 25

Rx

Rx

Tx

Tx

Serial Port

PC Port

Figure 4.4 – Automation Equipment Port Receive &

Figure 4.5 – PC Port Receive &

Transmit LEDs The LED’s flash when the PC is communicating with the TIU110

Transmit LEDs The LED’s flash when the TIU110

is communicating with the AE.

OFF

ON

SW 1

Figure 4.6 – Power Connector Powered by +24VDC and Ground. Figure 4.7 – Configuration Bank

Page 25 of the GE Operator Interface Terminal (HE500TIU110) user manual — TIU11X CUTOUT DETAILS
Page 25 · click to enlarge
Page 25

PAGE 26 06 Apr 2000 CH. 4: TIU110/111/112/113 GFK-1819

4.5.1 TIU11X Configuration of the RS-485 Port

The configuration bank (shown in Figure 4.8) sets the parameters of the RS-485 port as described in Table 4.1.

Table 4.1 – Configuration Bank Switch 1 ON: Pull-up (must be used together with switch 3) OFF: no Pull-up Switch 2 ON: 120Ω termination OFF: no termination Switch 3 ON: Pull-down (must be used together with switch 1) OFF: no Pull-down Switch 4 Reserved for future use NOTE: Switch 1 and 3 must be used together. Either both pull-up and pull-down are used or neither is used.

Pull-up and Pull-down switches are used to increase the signal level on the RS-485 bus. This is useful if there is a long bus and a significant amount of attenuation is anticipated.

Termination resistance of 120Ω must be placed across each end of the RS-485 bus. With switch 2 ON, a 120Ω resistance is placed across the bus. This should only be used if the TIU050/100/110 is the last device at either end of the bus.

4.6 TIU11X Dimensions

5.95” [151mm]

3.27” [83 mm] +0.02 -0.00

+0.5 -0.0

UP TO 0.04”[1mm] CORNER RADIUS IS ACCEPTABLE

TIU11X CUTOUT DETAILS

TOLERANCES ARE +/- 0.01” [0.3mm] UNLESS STATED OTHERWISE

Figure 4.8 – TIU11X Cutout

Page 26 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 5: TIU200/201/202/203
Page 26 · click to enlarge
Page 26
CH. 5TIU200/201/202/203 06 Apr 2000 PAGE 27

CHAPTER 5: TIU200/201/202/203

5.1 Scope The TIU20X is 240 x 128 pixel display which allows for full graphic screen. The hardware description is cover under the following chapter

GE Operator Interface Terminal (HE500TIU110) — CHAPTER 5: TIU200/201/202/203 diagram (page 26)
Fig. 13

F 9 F 1 0 F 11 F 1 3 F 1 2

F 1 4 F 1 5 F 1 6 F 1 7 F 1 8

5.2 TIU20X Button Selection Actions a) PAUSE key selects data for editing OR exits from data editing. b) PAUSE & DOWN keys pressed together, enters sub menu pages. c) PAUSE & UP keys pressed together, exits sub menus to the parent menu pages. d) UP key selects the previous menu page, sub menu page, alarms, and increments data e) DOWN key selects the next menu page, sub menu page, alarms and also decrements data. f) ENTER key sends data to the automation equipment, accepts alarms, and displays accepted alarms. g) ALPHANUMERIC KEYPAD can be used to enter data h) PROGRAMMABLE KEYS can be used to preform some pre-programmed action.

Page 27 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 5: TIU200/201/202/203
Page 27 · click to enlarge
Page 27

PAGE 28 06 Apr 2000 CH. 5: TIU200/201/202/203 GFK-1819

5.3 TIU20X Contrast Adjustment On menu page 1 (after the start-up screen), hold the ENTER key and press the UP or DOWN key to adjust the contrast. The contrast setting is stored and not lost after removing power.

CONTRAST BAND - allows the user to set the lower and upper limits of contrast. Adjust the lower limit using the UP or DOWN key and press Enter when done. Do the same for the upper limit. WARNING: - Changes to the lower or upper limits may allow the user to set the contrast to a setting where the display may appear blank. It is recommended that the factory setting are used (Min 8A, Max FE).

5.4 TIU20X Rear View

GE Operator Interface Terminal (HE500TIU110) — CHAPTER 5: TIU200/201/202/203 diagram (page 27)
Fig. 14

5.5 TIU20X Ports

GE Operator Interface Terminal (HE500TIU110) — CHAPTER 5: TIU200/201/202/203 diagram (page 27)
Fig. 15
Page 28 of the GE Operator Interface Terminal (HE500TIU110) user manual — OFF
Page 28 · click to enlarge
Page 28
CH. 5TIU200/201/202/203 06 Apr 2000 PAGE 29

Rx

Rx

Tx

Tx

Serial Port

PC Port

Figure 5.4 – Automation Equipment Port Receive &

Figure 5.5 – PC Port Receive &

Transmit LEDs The LED’s flash when the PC is communicating with the TIU20X

Transmit LEDs The LED’s flash when the TIU20X

is communicating with the AE.

GE Operator Interface Terminal (HE500TIU110) — Rx diagram (page 28)
Fig. 16 · Rx

OFF

ON

SW 1

Figure 5.7 – Configuration Bank

Figure 5.6 – Power Connector Powered by +24VDC and Ground.

Page 29 of the GE Operator Interface Terminal (HE500TIU110) user manual — 7,8 ; &87287 '(7$,/6
Page 29 · click to enlarge
Page 29

PAGE 30 06 Apr 2000 CH. 5: TIU200/201/202/203 GFK-1819

5.5.1 TIU20X Configuration of the RS-485 Port

The configuration bank (shown in Figure 2.23) sets the parameters of the RS-485 port as described in Table 5.1.

Table 5.1 – Configuration Bank Switch 1 ON: Pull-up (must be used together with switch 3) OFF: no Pull-up Switch 2 ON: 120Ω termination OFF: no termination Switch 3 ON: Pull-down (must be used together with switch 1) OFF: no Pull-down Switch 4 Reserved for future use NOTE: Switch 1 and 3 must be used together. Either both pull-up and pull-down are used or neither is used.

Pull-up and Pull-down switches are used to increase the signal level on the RS-485 bus. This is useful if there is a long bus and a significant amount of attenuation is anticipated.

Termination resistance of 120Ω must be placed across each end of the RS-485 bus. With switch 2 ON, a 120Ω resistance is placed across the bus. This should only be used if the TIU050/10X/11X/20X is the last device at either end of the bus.

5.6 TIU20X Dimensions

+0.02

µ > PP@

+0.02 -0.00

+0.5 -0.0

µ > PP@

83 72 µ &RUQHU >5$',86 ,6 $&&(37$%/(PP@

7,8 ; &87287 '(7$,/6

72/(5$1&(6 $5( µ >PP@ 81/(66 67$7(' 27+(5:,6(

Figure 5.8 – TIU20X Cutout

Page 30 of the GE Operator Interface Terminal (HE500TIU110) user manual — 5 RS232
Page 30 · click to enlarge
Page 30
CH. 6COMMUNICATIONS 06 Apr 2000 PAGE 31

CHAPTER 6: COMMUNICATIONS

6.1 PC to Operator Station Communications The serial pin connections for transmit (Tx), receive (Rx) and ground are displayed below.

GE Operator Interface Terminal (HE500TIU110) — CHAPTER 6: COMMUNICATIONS diagram (page 30)
Fig. 17

TIU1XX PC 2 Tx 2 Rx 3 Rx 3 Tx

Figure 6.1 – PC Programming Serial Port & Connection Detail

6.2 Automation Equipment (AE) Communications Connections 6.2.1 Recommended Automation Equipment Communication Cables Horner Electric recommends the following cables for automation equipment communication:

Belden No. 8105, 9807 or 9832 – General Purpose Belden No. 8165 – Heavy Noise Environment

6.3 RS-232 Connection

TIU110/100

AE

GE Operator Interface Terminal (HE500TIU110) — AE diagram (page 30)
Fig. 18

6 RS232

TIU050/101/102/103/111/112/113/20X

AE

GE Operator Interface Terminal (HE500TIU110) — AE diagram (page 30)
Fig. 19

5 RS232

Show 6 more labels / short text on this page
(Section of 13-pin · Rx · Tx · (Section of 8-pin · Rx · Tx
Page 31 of the GE Operator Interface Terminal (HE500TIU110) user manual — (4-wire)
Page 31 · click to enlarge
Page 31

PAGE 32 06 Apr 2000 CH. 6: COMMUNICATIONS GFK-1819

6.4 RS-422/485 Four-Wire

TIU110/100

GE Operator Interface Terminal (HE500TIU110) — TIU110/100 diagram (page 31)
Fig. 20

RS422/485

(4-wire)

0.1uF Ceramic

TIU050/101/102/103/111/112/113/20X

GE Operator Interface Terminal (HE500TIU110) — TIU050/101/102/103/111/112/113/20X diagram (page 31)
Fig. 21

RS422/485

Automated Equipment RS422/485 Connections See Note Below

(4-wire)

0.1uF Ceramic

(Section of 13-pin · (Section of 8-pin

Page 32 of the GE Operator Interface Terminal (HE500TIU110) user manual — CO M
Page 32 · click to enlarge
Page 32
CH. 6COMMUNICATIONS 06 Apr 2000 PAGE 33

6.5 RS-485 Two-Wire

TIU110/100

AE

GE Operator Interface Terminal (HE500TIU110) — AE diagram (page 32)
Fig. 22

RS422/485

(2-w ire)

CO M

0.1uF Ceramic

TIU050/101/102/103/111/112/113/20X

AE

GE Operator Interface Terminal (HE500TIU110) — AE diagram (page 32)
Fig. 23

RS422/485

(2-w ire)

CO M

0.1uF Ceramic

Figure 6.3 – RS-485 Two-Wire

Show 4 more labels / short text on this page
Tx/Rx+ · Tx/Rx- · Tx/Rx+ · Tx/Rx-
Page 33 of the GE Operator Interface Terminal (HE500TIU110) user manual — + SR
Page 33 · click to enlarge
Page 33

PAGE 34 06 Apr 2000 CH. 6: COMMUNICATIONS GFK-1819

6.6 Current Loop

The following diagram shows the connection to a device with an active 20mA current loop. The current loop on the TIU100/110 is passive. Either the PLC must provide the 20mA source or an external current source must be supplied.

+ SR

T+

20m A Loop 10 11

T-

R+

ST -

R-

Figure 6.4 – Current Loop

20mA Loop

Page 34 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 7: GETTING STARTED
Page 34 · click to enlarge
Page 34
CH. 7GETTING STARTED 06 Apr 2000 PAGE 35

CHAPTER 7: GETTING STARTED

7.1 Self-Test Power up the unit with the UP and ENTER keys pressed at the same time. The unit enters a self-test mode. The self-test consists of the following four checks:

7.1.1 Contrast Band This test allows the user to set the lower and upper limits of contrast. Adjust the lower limit using the UP or DOWN key and press Enter when done. Do the same for the upper limit. WARNING: - Changes to the lower or upper limits may allow the user to set the contrast to a setting where the display may appear blank. It is recommended that the factory setting are used (Min 8A, Max FE).

7.1.2 Display Test The display test continuously blinks all pixels on (black) to off. Look for any pixels stuck on or off. Exit this test by pressing and holding any key for approximately two seconds.

7.1.3 Keyboard Test

As each key is pressed, an indication *** appears above that key. In the case of units with a numeric keypad, press the key and a message appears indicating the key press. Check for keys indicating multiple presses or not reporting presses. Exit this test by pressing and holding any key for approximately two seconds.

7.1.4 RAM Test Test either segment 0000 or segment 1000 (on the TIU100/110) of the RAM. The segment 1000 test performs a base 3 repeating test. This test detects shorted address lines and damaged memory bits. The segment 0000 test performs a Read-Modify-Write test on each byte of RAM, detecting damaged memory bits. Exit this test by selecting DONE.

7.1.5 Serial Loop-back Tests Tests the PC port and the Serial Port in each of it’s three modes for serial loop-back. Pre-made plugs are required to link the pins of a particular port. This takes the following form:

Table 7.1 Loop-back Test Plugs Port Tested Product Type of Connector Pins to Short PC (J2) TIU100/110 Pin male D link connector pin 2 to pin 3 RS-232 (J3) TIU100/110 13-pin phoenix connection pin 6 to pin 8 RS-422/485 (J3) TIU100/110 13-pin phoenix connection pin 2 to pin 4 and pin 3 to pin 5. Current Loop TIU100/110 13-pin phoenix connection pin 1 to 9, pin 10 to 11 and pin 12 to 7 PC TIU050/101/102/1 03/112/113/20X Pin male D link connector pin 2 to pin 3

RS-232 TIU050/101/102/1 03/112/113/20X 8-pin phoenix connection Pin 5 to pin 7

RS-422/485 TIU050/101/102/1 03/112/113/20X 8-pin phoenix connection Pin 1 to pin 3, Pin 2 to pin 4 NOTE: current loop in not installed on standard models, as such a standard model will fail the current loop-back test. Current Loop is not an option on the TIU050/20X.

After starting the test, the OK counter begins to count up. Exit this test by selecting DONE.

Page 35 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 7: GETTING STARTED
Page 35 · click to enlarge
Page 35

PAGE 36 06 Apr 2000 CH. 7: GETTING STARTED GFK-1819

7.2 Updating the Protocol When the software is installed the user decides where the main CBREEZE folder resides. During installation the following folders are created: -

GE Operator Interface Terminal (HE500TIU110) — CHAPTER 7: GETTING STARTED diagram (page 35)
Fig. 24

In the protocol directory 3 folders are created, TIU0xx, TIU1xx and TIU2xx. The protocol files for the different terminal is loaded into these folders. The protocol files for the TIU050 are loaded into Tiu0xx, the protocol files for the TIU10X are loaded into Tiu10x and the protocol files for the TIU20X are loaded into Tiu20x. The name of the protocol file is broken up into three section, the protocol, the main software revsion and the terminal type that protocol file is for.

Protocol Name _ Software Revision . Terminal Type

Example snp_R4.1xx This is the protocol file for release 4 software for the GE FANUC PLC, for the TIU10X df1_R4.2xx This is the protocol file for release 4 software for Allen Brabley PLC, for the TIU20X

To Update Protocol File 1. Set Terminal Type 2. Set the required Automation Equipment in Communications Settings 3. Select Update TIU Protocol from the File menu. 4. Select the folder of the terminal you have connected to the PC. The correct file will appear for the terminal type selected and the Automation Equipment selected. Select that file and click OK. 5. A status bar appears indicating download progress. 6. After the transfer, the TIU050/10X/11X/20X resets itself. The correct PLC type is displayed on the TIU050/10X/11X/20X. 7. Next, the project loaded runs.

7.3 Updating the Operating System 1. Select Update Operating System from the File menu. 2. Choose the updated file with the “BIN” extension. Click OK. 3. A status bar appears indicating download progress. 4. During the download process, TIU050/10X/11X/20X displays the message “SYSTEM SHUTDOWN”.

Page 36 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 8 : NETWORKS
Page 36 · click to enlarge
Page 36
CH. 8NETWORKS 06 Apr 2000 PAGE 37

CHAPTER 8 : NETWORKS

8.1 Scope This chapter gives a brief introduction into the networking hardware available on the Operator Station range. The part numbers of the various options are available in the Introduction Chapter of this manual. For information on programming the various network options see GFK-1818, User Manual for the CBREEZE Software.

8.2 Controller Area Network (CAN) Overview The controller area network (or CAN bus) is a serial communications bus that was originally developed in the late 1980’s by a German company (Robert Bosch) for use in the automotive industry. CAN is an ISO (International Standards Organisation) - defined serial communications bus for real-time applications. Established in 1947, the International Standards Organisation (ISO) is a multinational body dedicated to worldwide agreement on international standards. Specifically, CAN is documented in ISO 11898 (for high-speed applications) and ISO 11519 (for lower-speed applications).

8.2.1 CAN Features CAN-based open automation technology successfully competes on the market of distributed automation systems because of the special features of the CAN protocol. The special features are CAN’s producer- consumer-oriented (or peer-to-peer) principle of data transmission and its multi-master capability. The general design of CAN originally specified a high bit rate, high immunity to electrical interference and an ability to detect any errors produced. CAN networks have the following general attributes:

  • Automatic error detection
  • Easily configurable
  • Cost-effective to design and implement
  • Capable of operating in harsh environments

8.3 CsCAN Network Overview The CsCAN Network was first developed in 1993 by Horner Electric. It was developed for use in a project that Horner Electric completed for the United States Post Office. Horner Electric developed its own network, because it needed a network that had a specific set of powerful peer-to-peer and host-to-node capabilities. The CsCAN Network has a “pass-through” feature whereby PC-based programs access other nodes connected to a network by passing the programming command through the serial port to the network port. (For a more detailed description, see below.) Horner Electric found that by developing its own network, it satisfied several important needs. Horner Electric continues CsCAN Network development to satisfy the requirements of today and the requirements of the future.

8.3.1 CsCAN Network Features The CsCAN Network is based on CAN, which has many desirable features such as ruggedness, ease of configuration, etc. With Horner Electric Controllers, data is passed at 125Kbps using a differential pair of wires plus a ground. It is important to note that the data rate is not limited to 125Kbps. The maximum data rate is 1Mbps (limited by the speed of light). The CAN implementation in the CsCAN controller allows up to 64 controllers to be networked with no additional hardware and up to 253 controllers with three CAN repeaters. For the programmer, little knowledge of networking procedures is needed. However for troubleshooting and optimizing, the following information is helpful. Instead of using master/slave or token passing, the hardware self-arbitrates based on the Network ID. Controllers with lower Network ID numbers are given a higher priority than controllers with higher Network ID numbers.

8.3.2 CsCAN Network Operation When a controller needs to send data over the network, it first waits for the network to be idle (currently a maximum of 900uS). If two controllers start broadcasting information on the network at the same time, the

Page 37 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 8 : NETWORKS
Page 37 · click to enlarge
Page 37

PAGE 38 06 Apr 2000 CH. 8: NETWORKS GFK-1819

"self-arbitration" causes the controller with the greater Network ID number to cease broadcasting without affecting the message-in-progress of the other controller.

In applications with a large number of networked controllers, better results may be achieved by assigning lower Network IDs to controllers that have more critical network data than other controllers. By assigning higher Network IDs to controllers that provide numerous network updates, the controllers are prevented from monopolising the bus time.

Each controller is capable of broadcasting Global Digital Output bits (%QG) and Global Analog Output bits (%AQG), which are periodically broadcasted to the other controllers on the network. The coil representations %QG and %AQG may be used in CBREEZE like any other coil or internal register reference.

All digital global outputs are broadcast to the network each time one of them has a state change. In addition, if a controller has not transmitted its global data for specific time period, the controller's programmable network timer may expire, which in turn results in a global data broadcast. Finally, as part of its power-up initialisation sequence, another controller can explicitly request a controller to broadcast its global data.

8.4 DeviceNet Overview DeviceNet is an open network. The specification and the protocol are open. Vendors are not required to purchase hardware, software or licensing rights to connect devices to a system.

8.4.1 DeviceNet Features DeviceNet is a low-cost communications link to connect industrial devices. It allows the interchangeability of simple devices while making interconnectivity of more complex devices possible. DeviceNet is based on CAN. It is an application layer protocol (ISO layer 7) and is defined in terms of an abstract object model, which represents the available communication services and the external visible behaviour of a DeviceNet node. The DeviceNet Model is application independent. DeviceNet provides the communication services needed by various types of applications. Many of today's lower level industrial control devices must retain their low cost/low resource characteristics even when directly connected to a network. DeviceNet takes this into consideration by defining a specific instance of the DeviceNet Model for communications typically seen in a Master/Slave application. This is referred to as the Predefined Master/Slave Connection Set. Some of the features and functionality of the DeviceNet network are described Table 8.1.

Table 8.1 - DeviceNet Features and Functionality Network Size Up to 64 Nodes Network Length Selectable end-to end network distance varies with speed

125 Kbps 500m (1,640 feet) 250 Kbps 250m (820 feet) 500 Kbps 100m (328 feet) Data Packets 0-8 bytes Bus Topology Linear (trunkline/dropline); power and signal on the same network cable Bus Addressing Peer-to-Peer with Multi-Cast (one-to-many); Multi-Master and Master/Slave special case; polled or change-of-state (exception-based) System Features

Removal and replacement of devices from the network under power

Baud Rate Distance

Page 38 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 8 : NETWORKS
Page 38 · click to enlarge
Page 38
CH. 8NETWORKS 06 Apr 2000 PAGE 39

8.4.2 DeviceNet Protocol Some of the communication protocol features of DeviceNet consist of the following:

1. A DeviceNet product can behave as a Client, a Server or both. 2. Master/Slave operation. 3. Capable of Peer-to-Peer exchange capability exists in which any DeviceNet product can produce and consume messages. 4. Capable of supporting 64 node addresses 5. Each node can support an unlimited number of I/O.

8.4.3 DeviceNet Operation The following restrictions are placed on operations when using an OS that is configured as a DeviceNet slave. 1. Currently, communication between the PC and the controller is only possible to the device physically connected to the PCs’ serial port. Project downloads, uploads, monitoring, and configuration cannot currently take place over a DeviceNet network. 2. The HE200CGM40x gateway card can not currently be used with DeviceNet communications. Horner Electric is providing a special Gateway device that is based on the OCS hardware. The Gateway device makes it possible to connect the PC serial port with the DeviceNet network. 3. DeviceNet network nodes are in a range from 0 to 63. The controller is able to observe network responses (polled connections) from any slave to the DeviceNet Master. The first 16-words of these observed responses are made available for mapping on the Network Input Assignments page. These correspond to the available nodes 0 to 63 and registers AQG1 to AQG16. Node 64 is used for a special case. When data is sent to a controller from a DeviceNet Master (via the polled connection) this data is mapped to node 64. Relative addressing is limited to -64 to +64.

Page 39 of the GE Operator Interface Terminal (HE500TIU110) user manual — SH IE LD
Page 39 · click to enlarge
Page 39

PAGE 40 06 Apr 2000 CH. 8: NETWORKS GFK-1819

8.5 CAN Wiring Rules

SH IELD

SH IELD

SH IELD

SH IELD

C N_H

C N_H

C N_H

C N_H

C N_L

C N_L

C N_L

C N_L

V+

V+

V+

V+

GE Operator Interface Terminal (HE500TIU110) — SH IELD diagram (page 39)
Fig. 25

12-25VD C +

SH IE LD

SH IE LD

SH IE LD

C N _ L

C N _ H

C N _ L

C N _ H

C N _ L

C N _ H

C N _ L

C N _ H

V +

V +

V +

V +

GE Operator Interface Terminal (HE500TIU110) — SH IE LD diagram (page 39)
Fig. 26

1. Wire the CAN network in a daisy-chained fashion such that there are exactly two physical end-points on the network. 2. The two nodes at the physical end-points need to have 121 ohm 1% terminating resistors connected across the CN_L and CN_H terminals. 3. Use data conductors (CN_L and CN_H) that are 24 AWG shielded twisted pair for “thin cable” and 22 AWG shielded twisted pair for “thick cable”. They must also have 120-ohm characteristic impedance. In typical industrial environments, use a Belden wire #3084A (“thin”). Use #3082A (“thick”) for environments where noise is a concern. 4. Use power conductors (V- and V+) that are 18 AWG twisted-pair for “thin cable” and 15 AWG twisted- pair for “thick cable”. 5. Connect the V- power conductor to a good earth ground at one place only on the network, preferably physical endpoints. 6. For a section of cable between two nodes, the cable shield is connected to the cable shield input at one end of the cable only. 7. A CAN network (without repeaters) is limited to 64 nodes (with 63 cable segments) with a maximum cable length of 1500 ft. 8. Up to four CAN network segments, which adhere to the above rules, may be connected together using three CAN repeaters. In this manner, a CAN network may be extended to 253 nodes with a total cable distance of 6000 ft.

Page 40 of the GE Operator Interface Terminal (HE500TIU110) user manual — Station 1 Station 2
Page 40 · click to enlarge
Page 40
CH. 8NETWORKS 06 Apr 2000 PAGE 41

8.6 Profibus Profibus utilises a Master-Slave type of communication with the TIUXX2 functioning as a slave device. Decentralised Peripherals (Slave) Baud rates of up to 12 MBd can be obtained through Profibus.

Up to 32 devices 9master or slaves) can be connected in one segment without using repeaters, or up to 64 devices can be connected using repeaters.

Master devices are used to determine the data communication on the bus. One master can service several slaves. Several Masters can participate on the bus simultaneously, but only one Master can write outputs to a slave.

The slave devices are peripheral devices. Slaves do not have bus access rights and can only acknowledge received messages or send messages to the master when requested to do so. Any master can read data from the slave devices. All connected Slaves have the same priority.

For further information on the Profibus Network, visit their website at www.profibus.com

8.6.1 Profibus Wiring The TIUXX2 uses a 9 pin D-sub plug connector for its Profibus port. The pin assignment of the plug connector and the wiring are show below.

Station 1 Station 2

Rxd/TxD -P 3

V+ 6

D G nd 5

RxD /TxD -N 8

Protective G round

Figure 8.4 Profibus Port Pinout

Page 41 of the GE Operator Interface Terminal (HE500TIU110) user manual — G N D (5 )
Page 41 · click to enlarge
Page 41

PAGE 42 06 Apr 2000 CH. 8: NETWORKS GFK-1819

R x D /T xD -N 8

R x D /T xD -N 8

R x D /T xD -N 8

R x D/Tx D -P 3

R x D/Tx D -P 3

R x D/Tx D -P 3

D G N D 5

D G N D 5

D G N D 5

V + 6

V + 6

V + 6

GE Operator Interface Terminal (HE500TIU110) — D G N D 5 diagram (page 41)
Fig. 27

Its is necessary to terminate both ends of the network. Both terminations must have power to them to insure proper operation of the network. The following diagram illustrates the correct connection for the termination resistors.

V P (6 )

GE Operator Interface Terminal (HE500TIU110) — V P (6 ) diagram (page 41)
Fig. 28

L in e term in atio n 3 90 O h m

A -L in e (3 )

2 20 O h m

B -L in e (8 )

3 90 O h m

G N D (5 )

Figure 8.6 – Profibus termination resistors

Page 42 of the GE Operator Interface Terminal (HE500TIU110) user manual — CHAPTER 9: SMARTSTACK
Page 42 · click to enlarge
Page 42
CH. 9SMARTSTACK 06 Apr 2000 PAGE 43

CHAPTER 9: SMARTSTACK

9.1 Scope Horner has now added the SmartStack modules from the OCS Range to the TIU20X range. The SmartStack system is a method of allowing I/O expansion on an HMI. A wide range of modules is available including Digital and Analogue.

9.2 Installing and Removing a SmartStack Module The following section describes how to install and remove a SmartStack Module.

9.2.1 Installing SmartStack Modules

1. Hook the tabs. Each SmartStack Module has two tabs that fit into slots located on the TIU20X. (The slots on the TIU20X are located on the back cover.) 2. Press the SmartStack Module into the “locked” position, making sure to align the SmartStack Module fasteners with the SmartStack receptacles on the TIU20X.

9.2.2 Removing SmartStack Modules

1. Using a Flathead screwdriver, pry up the end of the SmartStack Module (opposite of tabs) and swing the module out. 2. Lift out the tabs of the module.
GE Operator Interface Terminal (HE500TIU110) — CHAPTER 9: SMARTSTACK diagram (page 42)
Fig. 29

Figure 9.1 – Installing a SmartStack Module in an OCS.

Page 43 of the GE Operator Interface Terminal (HE500TIU110) user manual — NOTES
Page 43 · click to enlarge
Page 43

PAGE 44 06 Apr 2000 CH. 9: SMARTSTACK GFK-1819

NOTES

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the GE Operator Interface Terminal (HE500TIU110)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE Operator Interface Terminal (HE500TIU110)

Be the first to ask — other owners or our team will answer.

Original document

GE Operator Interface Terminal (HE500TIU110) manual PDF

43 pages·563 KB·Cell Phone·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…