System is Tested and Certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine, Taste and Odor and Particulate Class I and Standard 53 for the reduction of Turbidity.
Drill with 1/8″ Drill Bit
238C3375P001 49-50225-1 07-07 JR Printed in China
Phillips-Head Screwdriver · Utility Knife · Adjustable Wrench

CARTRIDGE SPECIFICATIONS Performance Data – Filtration System GXULQ Using Filter GXULQR I This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53. I Actual performance may vary with local water conditions. I Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after
the system.
STEP-BY-STEP INSTALLATION INSTRUCTIONS Installation Overview NOTE: Be sure to allow a minimum space of 11/2″–2″ under the system for removing the filter cartridge. If you have copper tubing with 3/8″ compression fittings, you’ll need to follow Step 3 Option B (Optional Installation).
Push filter into the filter head/bracket. Turn filter 1/4 turn to the right until it stops. The top surface of the filter will be flush with the bottom of the filter head/bracket when fully installed.
3/8″ x 1/2″ Push to Connect Adapter Filter Head/ Bracket
OUT
INSTALLING THE SYSTEM
HOT COLD
A
IN
B
HOT COLD
FILTER CARTRIDGE REPLACEMENT Replacement Filter Canister/Estimated Replacement Costs GXULQR—Replacement filter canister $29–34 For replacement parts, call toll-free 800.626.2002 (U.S.), 800.663.6060 (Canada–English), 800.361.3869 (Canada–French) TO REMOVE FILTER:
DISCONNECT COLD WATER SUPPLY Remove items from under the sink. Place a bucket and some towels under the sink to collect any water that may run out when disconnecting the water supply lines. Turn off the cold water supply valve and remove the existing water supply tubing and fittings. NOTE: For copper tubing, leave the 3/8″ compression fitting on the faucet stem. Go to Step 3, Option B.

INSTALL FAUCET ADAPTER Install the 3/8″ x 1/2″ faucet adapter to the faucet threads. DO NOT OVERTIGHTEN. Option A – Typical Installation
CUTTING THE TUBING Determine the length of tubing necessary from the filter head/bracket to the faucet and from the water supply line to the filter head/bracket by holding the tubing in place to ensure it is the correct length.
NOTE: 6 feet of tubing is supplied. Cut the tubing into two sections according to your requirements. Cut tubing. NOTE: Do not kink tubing. NOTE: Check the end of the tubing to make sure there are no cuts, nicks, flat spots or sharp edges. If any of these are present, cut the end of the tube with a utility knife. Measure 3/4″ from the end of the tubing provided and mark with a pencil. C
Option B – Optional Installation If you have copper tubing with a compression adapter, you will NOT use the 1/2″ faucet adapter. Use a section of tubing, slide the compression hex nut and 3/8″ ferrule (tapered end away from the compression nut) onto the tubing, and put in the tubing insert.
INCORRECT CUT
3/8″ Compression adapter
INSTALL TUBING Push the tubing firmly into the collet on the faucet adapter fitting until the pencil mark is pushed next to the collet. (If the tubing is removed, recut the end, measure, mark and reinsert.)
INSTALL THE HEAD/BRACKET Using the filter head/bracket as a guide, mark hole locations so that there is 1″ between the center of each screw. Fasten the filter head/bracket to the wall with the Phillips screws provided with the unit. NOTE: Predrill 1/8″ holes for easier installation. Make sure to leave at least 2-1/2″ from the bottom of the system to allow for easy replacement of the filter cartridge. Install screws only halfway so you can slip the bracket onto the wall during installation. NOTE: There are three installation configurations. Select the appropriate screws for installation: For Cabinet Side Wall Installations, use 1″ screws; For Drywall into Stud Installations, use 1-1/4″ screws; For Drywall with No Stud Installations, use lag bolts. CAUTION: Be sure screw point does not protrude through the wall into adjacent cabinet. Tighten screws to secure the bracket. D
Tubing must be fully inserted to avoid leaks. To remove tubing: Depress and hold the white collet; pull the tubing out to remove.
White Collet (DO NOT REMOVE)
Engagement 3/4″ (1/4″ tubing)
Pull out slightly on the tubing to ensure a good seal. Press the other end of the tubing into the outlet side of the filter. C B

INSTALL COMPRESSION FITTINGS Take the remaining section of tubing, slide the compression hex nut and 3/8″ ferrule (tapered end away from the compression nut) onto the tubing, and put in the tube insert.
FINAL CHECK Insert the filter into the filter head/bracket. Turn the filter 1/4 turn to the right until it stops. The top surface of the filter will become flush with the bottom of the filter head/bracket when it is fully installed. Slowly turn on the water supply. Check the entire system for leaks. If there are leaks, refer back to the Cut the Tubing section to reinsert the tubing. If leaking from fittings, shut off water pressure and tighten or reseal fittings. If leaking from the filter, tighten the filter. After installation, let water run for approximately 5 minutes to flush the filter and to remove air. NOTE: It is normal for there to be air in the system causing bubbles in the water.
A
Shut-Off Valve Tubing Insert Ferrule Hex Nut Tubing
B
Fasten the assembly onto the cold water supply valve. Do not overtighten.
Shut-Off Valve Tubing Insert Ferrule Hex Nut Tubing
INSTALL THE BATTERIES Insert coin or screwdriver in the slot between the timer cap and base. Gently pry open and separate the timer base from the cap. Install or change 2 new AAAbatteries. After having the batteries in place, line up the base and cap and snap them back together. After new batteries are installed or filter is changed, push and hold the timer blue reset button for approximately 5 seconds. Release the reset button after the light flashes 5 times. The light will flash again in 180 days to remind you that it is time to change the filter. Attach timer to remote location for easy viewing. D
B
Ref. No. Part No. Part Description 001 GXULQR Replacement Filter Cartridge 1 002 WS19X10024 Filter Head/Bracket 1 003 GXULQ-KIT Kit 1 004 GXULQ-TIMER Timer and Batteries 1 To obtain replacement parts, call toll-free 800.626.2002 (U.S.), 800.663.6060 (Canada–English), 800.361.3869 (Canada–French). GE Consumer & Industrial
Appliances General Electric Company
of Purchase.” A new or reconditioned unit will be provided. This warranty excludes the cost of shipping the product to your home.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product exchange as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
for other than the intended purpose. — Use of this product where water is microbiologically unsafe or of unknown quality,
without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. — Damage to the product caused by accident, fire, floods or acts of God. — Incidental or consequential damage caused by possible defects with this
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home or office use within the USA. In Alaska, the warranty excludes the cost of shipping or service to your home or office. Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General. Contact us at ge.com, or call toll-free at 800.952.5039 in the U.S., or 866.777.7627 in Canada.
appliance, its installation or repair. • For how long after the original purchase? — One (1) year.


Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.