Page 1 of the GE GNULQ user manual — TOOLS YOU WILL NEED
Page 1 · click to enlarge
Page 1

Installation Kitchen and Bath Main Faucet Instructions Filtration System – GXULQ/GNULQ

  • SAFETY PRECAUTIONS
  • Check with your state and local public works department for plumbing and sanitation codes. You must follow these guidelines as you install the Kitchen and Bath Main Faucet Filtration System. Using a qualified installer is recommended.
  • Be sure the water supply conforms with the Performance Data . If the water supply conditions are unknown, contact your municipal water company.
  • PROPER INSTALLATION This Kitchen and Bath Main Faucet Filtration System must be properly installed and located in accordance with the Installation Instructions before it is used.
  • Check with your local public works department for plumbing codes. You must follow their guides as you install the Kitchen and Bath Main Faucet Filtration System.
  • Use the Kitchen and Bath Main Faucet Filtration System on a potable, safe-to-drink, home COLD water supply only. The filter cartridge will not purify water or make unsafe water safe to drink. DO NOT use on HOT water (100°F max).
  • Protect the Kitchen and Bath Main Faucet Filtration System and piping from freezing. Water freezing in the system will damage it.
  • Your Kitchen and Bath Main Faucet Filtration System will withstand up to 100 psi water pressure. If your house water supply pressure is higher than 100 psi during the day (it may reach higher levels at night), install a pressure reducing valve before the system is installed.
  • Do not install on HOT WATER . The temperature of the water supply to the Kitchen and Bath Main Faucet Filtration System must be between the minimum of 40°F and the maximum of 100°F. See the Performance Data section.
  • Do not install the Kitchen and Bath Main Faucet Filtration System using copper solder fittings. The heat from the soldering process will damage the unit.

PARTS INCLUDED

  • Filter Cartridge
  • Filter Head/Bracket
  • 6 Feet of 3/8 ″ Tubing
  • 3/8 ″ x 1/2 ″ Faucet Adapter
  • 3/8 ″ Compression Hex Nut
  • 3/8 ″ Ferrule
  • 3/8 ″ Tube Insert
  • Mounting Screws
  • 1/2 ″ Compression to 3/8 ″ Adapter
  • 7/16 ″ Compression to 3/8 ″ Adapter Optional accessories are available (Visa, MasterCard or Discover cards accepted) by visiting our Website at <a href="http://ge.com" rel="nofollow noopener" target="_blank">ge.com</a> or from Parts and Accessories, call 800.626.2002 (U.S.) or 800.663.6060 (Canada).

TOOLS YOU WILL NEED

System is Tested and Certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine, Taste and Odor and Particulate Class I and Standard 53 for the reduction of Turbidity.

Drill with 1/8″ Drill Bit

238C3375P001 49-50225-1 07-07 JR Printed in China

Phillips-Head Screwdriver · Utility Knife · Adjustable Wrench

Page 2 of the GE GNULQ user manual — B
Page 2 · click to enlarge
Page 2

CARTRIDGE SPECIFICATIONS Performance Data – Filtration System GXULQ Using Filter GXULQR I This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the

indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53. I Actual performance may vary with local water conditions. I Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after

the system.

Standard No. 42: Aesthetic Effects ParameterUSEPA MCLInfluent Challenge ConcentrationInfluent AverageEffluent% ReductionReduction Requirement Average MaximumAverage Minimum Chlorine taste andodor —2.0 mg/L ± 10%1.9 mg/L<0.05 mg/L 0.05 mg/L>97.4% 97.4%≥50% Particulate, Class I particles 0.5 to <1um** —≥10000 particles/mL10333333 #/mL20,500 #/mL 41,000 #/mL99.8% 99.6%≥85% Standard No. 53: Health Effects ParameterUSEPA MCLInfluent Challenge ConcentrationInfluent AverageEffluent% ReductionReduction Requirement Average MaximumAverage Minimum Turbidity1 NTU***11 ± 1 NTU***11.00 NTU0.1 NTU 0.1 NTU99.1% 99.1%0.5 NTU

STEP-BY-STEP INSTALLATION INSTRUCTIONS Installation Overview NOTE: Be sure to allow a minimum space of 11/2″–2″ under the system for removing the filter cartridge. If you have copper tubing with 3/8″ compression fittings, you’ll need to follow Step 3 Option B (Optional Installation).

FILTER CARTRIDGE REPLACEMENT (cont.) TO REPLACE FILTER:

A

Push filter into the filter head/bracket. Turn filter 1/4 turn to the right until it stops. The top surface of the filter will be flush with the bottom of the filter head/bracket when fully installed.

3/8″ x 1/2″ Push to Connect Adapter Filter Head/ Bracket

B

IN

OUT

INSTALLING THE SYSTEM

HOT COLD

  • SELECT A LOCATION Select a location for the system that is:
  • Protected from freezing.
  • Not exposed to direct sunlight. Select and mark a location under the sink that allows access for a filter cartridge change. See Section 4. The system can be mounted vertically or horizontally. DO NOT MOUNT THE SYSTEM UPSIDE DOWN.

OUT

A

IN

B

HOT COLD

FILTER CARTRIDGE REPLACEMENT Replacement Filter Canister/Estimated Replacement Costs GXULQR—Replacement filter canister $29–34 For replacement parts, call toll-free 800.626.2002 (U.S.), 800.663.6060 (Canada–English), 800.361.3869 (Canada–French) TO REMOVE FILTER:

DISCONNECT COLD WATER SUPPLY Remove items from under the sink. Place a bucket and some towels under the sink to collect any water that may run out when disconnecting the water supply lines. Turn off the cold water supply valve and remove the existing water supply tubing and fittings. NOTE: For copper tubing, leave the 3/8″ compression fitting on the faucet stem. Go to Step 3, Option B.

A

  • Turn filter 1/4 turn to the left. The top surface of the filter will move away from the bottom of the head. Pull the filter down to remove.

B

Show 6 more labels / short text on this page
Tubing insert · Hex nut · Ferrule · Shut-Off Valve · Filter Cartridge · Optional installation
Page 3 of the GE GNULQ user manual — B
Page 3 · click to enlarge
Page 3

INSTALL FAUCET ADAPTER Install the 3/8″ x 1/2″ faucet adapter to the faucet threads. DO NOT OVERTIGHTEN. Option A – Typical Installation

CUTTING THE TUBING Determine the length of tubing necessary from the filter head/bracket to the faucet and from the water supply line to the filter head/bracket by holding the tubing in place to ensure it is the correct length.

A

NOTE: 6 feet of tubing is supplied. Cut the tubing into two sections according to your requirements. Cut tubing. NOTE: Do not kink tubing. NOTE: Check the end of the tubing to make sure there are no cuts, nicks, flat spots or sharp edges. If any of these are present, cut the end of the tube with a utility knife. Measure 3/4″ from the end of the tubing provided and mark with a pencil. C

B

Option B – Optional Installation If you have copper tubing with a compression adapter, you will NOT use the 1/2″ faucet adapter. Use a section of tubing, slide the compression hex nut and 3/8″ ferrule (tapered end away from the compression nut) onto the tubing, and put in the tubing insert.

CORRECT CUT

INCORRECT CUT

3/8″ Compression adapter

INSTALL TUBING Push the tubing firmly into the collet on the faucet adapter fitting until the pencil mark is pushed next to the collet. (If the tubing is removed, recut the end, measure, mark and reinsert.)

A

INSTALL THE HEAD/BRACKET Using the filter head/bracket as a guide, mark hole locations so that there is 1″ between the center of each screw. Fasten the filter head/bracket to the wall with the Phillips screws provided with the unit. NOTE: Predrill 1/8″ holes for easier installation. Make sure to leave at least 2-1/2″ from the bottom of the system to allow for easy replacement of the filter cartridge. Install screws only halfway so you can slip the bracket onto the wall during installation. NOTE: There are three installation configurations. Select the appropriate screws for installation: For Cabinet Side Wall Installations, use 1″ screws; For Drywall into Stud Installations, use 1-1/4″ screws; For Drywall with No Stud Installations, use lag bolts. CAUTION: Be sure screw point does not protrude through the wall into adjacent cabinet. Tighten screws to secure the bracket. D

A

Tubing must be fully inserted to avoid leaks. To remove tubing: Depress and hold the white collet; pull the tubing out to remove.

B

White Collet (DO NOT REMOVE)

Engagement 3/4″ (1/4″ tubing)

Pull out slightly on the tubing to ensure a good seal. Press the other end of the tubing into the outlet side of the filter. C B

Show 13 more labels / short text on this page
Faucet Threads · Adapter · 3/4″ · Copper tubing · Ferrule · Hex nut · Insert · Tubing · 2-1/2″ · 3/4″ · 3 4" · Pencil mark line · Insert tubing
Page 4 of the GE GNULQ user manual — LIMITED ONE YEAR WARRANTY
Page 4 · click to enlarge
Page 4

INSTALL COMPRESSION FITTINGS Take the remaining section of tubing, slide the compression hex nut and 3/8″ ferrule (tapered end away from the compression nut) onto the tubing, and put in the tube insert.

FINAL CHECK Insert the filter into the filter head/bracket. Turn the filter 1/4 turn to the right until it stops. The top surface of the filter will become flush with the bottom of the filter head/bracket when it is fully installed. Slowly turn on the water supply. Check the entire system for leaks. If there are leaks, refer back to the Cut the Tubing section to reinsert the tubing. If leaking from fittings, shut off water pressure and tighten or reseal fittings. If leaking from the filter, tighten the filter. After installation, let water run for approximately 5 minutes to flush the filter and to remove air. NOTE: It is normal for there to be air in the system causing bubbles in the water.

A

A

Shut-Off Valve Tubing Insert Ferrule Hex Nut Tubing

C B

B

Fasten the assembly onto the cold water supply valve. Do not overtighten.

D

Shut-Off Valve Tubing Insert Ferrule Hex Nut Tubing

E

PARTS LIST

INSTALL THE BATTERIES Insert coin or screwdriver in the slot between the timer cap and base. Gently pry open and separate the timer base from the cap. Install or change 2 new AAAbatteries. After having the batteries in place, line up the base and cap and snap them back together. After new batteries are installed or filter is changed, push and hold the timer blue reset button for approximately 5 seconds. Release the reset button after the light flashes 5 times. The light will flash again in 180 days to remind you that it is time to change the filter. Attach timer to remote location for easy viewing. D

A

B

Ref. No. Part No. Part Description 001 GXULQR Replacement Filter Cartridge 1 002 WS19X10024 Filter Head/Bracket 1 003 GXULQ-KIT Kit 1 004 GXULQ-TIMER Timer and Batteries 1 To obtain replacement parts, call toll-free 800.626.2002 (U.S.), 800.663.6060 (Canada–English), 800.361.3869 (Canada–French). GE Consumer & Industrial

Appliances General Electric Company

LIMITED ONE YEAR WARRANTY

  • What does this warranty cover? — Any defect in materials or workmanship in the manufactured product.
  • What does this warranty not cover? — Filter cartridge and batteries after 30 days from date of purchase. — Service trips to your home to teach you how to use the product. — Improper installation, delivery or maintenance. — Failure of the product if it is abused, misused, altered, used commercially or used
  • How do I make a warranty claim? — Return to the retailer from which it was purchased, along with a copy of the “Proof

of Purchase.” A new or reconditioned unit will be provided. This warranty excludes the cost of shipping the product to your home.

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product exchange as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

for other than the intended purpose. — Use of this product where water is microbiologically unsafe or of unknown quality,

without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. — Damage to the product caused by accident, fire, floods or acts of God. — Incidental or consequential damage caused by possible defects with this

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home or office use within the USA. In Alaska, the warranty excludes the cost of shipping or service to your home or office. Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General. Contact us at ge.com, or call toll-free at 800.952.5039 in the U.S., or 866.777.7627 in Canada.

appliance, its installation or repair. • For how long after the original purchase? — One (1) year.

Show 5 more labels / short text on this page
Blue Reset Button · Timer Cap · 2 AAA Batteries · Timer Base · Louisville, KY 40225
Page 5 of the GE GNULQ user manual — English
Page 5 · click to enlarge
Page 5
GE GNULQ — English diagram (page 5)
Fig. 1 · English
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the GE GNULQ

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE GNULQ

Be the first to ask — other owners or our team will answer.

Original document

GE GNULQ manual PDF

16 pages·707 KB·Water System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…