Water Softening system
Safety Information 2
Installation Instructions. . .3–14 Step-by-step instructions 6–14
Operating Instructions Breaking a salt bridge 16 Cleaning the nozzle and venturi assembly 16 Features 17 Service 15, 18–20 Water softener system 15–20
Sistema Suavizante
Care and Cleaning 21
Manual del Propietario e Instrucciones de Instalación
Consumer Support Consumer Support Back Cover Parts list/catalog 27–30 Warranty (U.S.) 31 Warranty (Canada) 32
La sección en español empieza en la página 33
System tested and certified by NSF International against NSF/ANSI Standard 44 for the chemical reduction claims specified on the performance data sheet.
Sistema probado y certificado por NSF International contra norma 44 de NSF/ANSI para las afirmaciones de reducción de los productos químicos especificadas en la hoja de datos de funcionamiento.
Write the model and serial numbers here:
To find these numbers, lift the cover and look on the rim below the control panel.

For your safety, the information in this manual must be followed to minimize the risk of electric shock, property damage or personal injury.
I Check and comply with your state and local codes.
I Use clean water softening salts only, at least 99.5%
You must follow these guidelines.
pure. NUGGET, PELLET or coarse SOLAR salts are recommended. Do not use rock, block, granulated or ice cream making salts. They contain dirt and sediments, or mush and cake, and will create maintenance problems.
I Use care when handling the water softening
system. Do not turn upside down, drop, drag or set on sharp protrusions.
I Water softening systems using sodium chloride
I Keep the salt hole cover in place on the softener
(salt) for recharge add sodium to the water. Persons on sodium restricted diets should consider the added sodium as part of their overall intake. Potassium chloride can be used as an alternative to sodium chloride in your softener.
unless servicing the unit or refilling with salt.
I The water softening system works on 24 volt-60 Hz
electrical power only. Be sure to use only the included transformer.
I Transformer must be plugged into an indoor
120 volt, grounded outlet only.
This water softening system must be properly installed and located in accordance with the Installation Instructions before it is used.
I Install or store where it will not be exposed to
I Softener resins may degrade in the presence of
temperatures below freezing or exposed to any type of weather. Water freezing in the system will break it. Do not attempt to treat water over 100°F.
chlorine above 2 ppm. If you have chlorine in excess of this amount, you may experience reduced life of the resin. In these conditions, you may wish to consider purchasing a GE point-of-entry household filtration system with a chlorine reducing filter.
I Do not install in direct sunlight. Excessive sun or
heat may cause distortion or other damage to non-metallic parts.
I Properly ground to conform with all governing
codes and ordinances.
I Use only lead-free solder and flux for all
sweat-solder connections, as required by state and federal codes.
I The water softening system requires a minimum
water flow of three gallons per minute at the inlet. Maximum allowable inlet water pressure is 125 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. Use a pressure reducing valve to reduce the flow if necessary.

IMPORTANT INSTALLATION RECOMMENDATIONS (CONT.)
Read these instructions completely and carefully.

WHERE TO INSTALL THE SOFTENER
Be sure to check the entire softener for any shipping damage or parts loss. Also note damage to the shipping cartons. Contact the transportation company for all damage and loss claims. The manufacturer is not responsible for damages in transit.
Small parts needed to install the softener are packaged either in a bag or on a cardboard sheet. To avoid loss of the small parts, keep them packaged until you are ready to use them. Be sure not to discard components hidden in packaging.


INSTALL DRAIN FITTING
Turbine Valve outlet Turbine shaft and support
Before sliding softener in position, be sure the installation surface is level and smooth. Sharp objects under the tank may puncture it. If needed, place the tank on a section of 3/4″ thick (minimum) plywood. Then, place shims under the plywood as needed to level the softener. Slide softener into position.
O-ring seal goes into the outer groove only. The clip snaps into the inner groove (see below).
END VIEW
Bypass valve (push all the way in)
Valve body inlet or outlet

PLUMB “IN” AND “OUT” PIPES TO AND FROM SOFTENER CAUTION: Observe all of the following cautions as you connect inlet and outlet plumbing. See Typical Installation Illustration.
1/4″ NPT thread
Barbs for 3/8″ I.D. tubing
Turn bypass valve upside down to connect to floor level plumbing
IN
Be sure the clips for the bypass valve and NPT adapters snap into place. Pull on the bypass valve and NPT adapters to make sure the parts are held securely in place.
Hose clamp · Drain hose


Drain fitting on valve
Tie or wire hose in place
11⁄2″ air gap
CONNECTING A RIGID VALVE DRAIN TUBE
To adapt a copper drain tube to the softener, buy a compression fitting (1/4 NPT x 1/2″ O.D. tube) and needed tubing from your local hardware store.
1/4″ NPT thread
Compression fitting 1/4 NPT x 1/2″ O.D. tube (not provided)
Cut barbs from valve drain elbow (pull clip and remove drain valve elbow from valve)
1/2″ outside diameter copper tube (not provided)

INSTALL GROUNDING CLAMP DANGER: Failure to properly attach ground clamp could result in electrical shock.
FLUSH PIPES, EXPEL AIR FROM SOFTENER AND TEST YOUR INSTALLATION FOR WATER LEAKS (CONT.)
If plumbing is metal, to maintain electrical ground continuity in the house cold water piping, install the included ground clamp as shown.
SLOWLY pull or slide the valve stem (out) toward the service position, pausing several times to allow the softener to pressurize slowly.
FLUSH PIPES, EXPEL AIR FROM SOFTENER AND TEST YOUR INSTALLATION FOR WATER LEAKS CAUTION: To avoid water or air pressure damage to softener inner parts, be sure to do the following steps in exact order.
To valve inlet · Ground Clamp · From valve outlet

To gain access to the transformer/power cord assembly, remove the salt hole cover from the softener. Unclip the tabs on the rear of the top cover and rotate the cover upward to remove. DO NOT PULL OR DISCONNECT WIRING.
SET PRESENT TIME OF DAY
PM
CONTROL SETTINGS REQUIRED upon installation and after an extended power outage.
. If the present time is between noon and midnight,
be sure PM shows in the display. If the present time is between midnight and noon, be sure AM shows in the display.
If - - - is flashing, use the UP button to set the correct F or P code as follows: P39 for GXSH39E or P45 for GNSH45E. If you pass by the correct code number, use the DOWN button. Then press the MODE button to accept the correct model.

SET SALT LEVEL
You can get the grains per gallon (gpg) hardness of your water supply from a water analysis laboratory. If you are on a municipal supply, call your local water department. Or call Legend Technical Services, an independent laboratory, to request a water hardness test kit at 1.800.949.8220, Option 4. If your report shows hardness in parts per million (ppm) or milligrams per liter (mg/l), simply divide by 17.1 to get the equivalent number of grains per gallon.
DAYS TO EMPTY PM
SET RECHARGE (STARTING) TIME
E
RECHARGE TONIGHT
SALT LEVEL
The words DAYS TO EMPTY and a number are shown in the lower half of the display. This information is shown in the normal run display. This is to inform the user of the number of days before the salt level in the brine tank reaches Level 0. There will be salt left in the salt tank, but it may not be sufficient to fully recharge the system. Salt should be added at this time to avoid hard water. The value is updated daily and whenever the SALT LEVEL value is changed.
DAYS TO EMPTY PM
If no change is needed, go to step 3. To change the recharge starting time, follow step 2.
It takes a couple of months for the water softener to learn your water usage pattern. Once it does this, it will accurately determine actual salt usage pattern. During this first period, check salt level when blue indicator light flashes. If the salt level in the tank is at Level 1 or above, allow system to run. Be sure to reset your salt level indicator each time you add salt to the system.

FEATURE: OTHER DATA DISPLAYS
The controller display has several options and features.
These models have an option to have the run display indicate different information. The information displayed on the top half of the display can be changed to one of the following:
SALT LEVEL
The LOW SALT ALARM, when enabled, will sound the beeper when the DAYS TO EMPTY value is 15 days or less. To change this setting, press and hold the MODE button for 3 seconds. ON (factory default) or OFF will flash in the display. Press the UP
or DOWN buttons to toggle this feature ON or OFF. Press the MODE button to accept, and the display will move to SALT EFFICIENCY.
When PRESENT TIME is displayed, press the DOWN button; % REM will appear in the display. The value shown is between 0 and 100 percent. This value is based on current operating capacity. Pressing the UP button will return the screen to the previous display.
%REM ADG GPM
DAYS TO EMPTY
E
SALT EFFICIENCY
SALT LEVEL
RECHARGE TONIGHT
When the SALT EFFICIENCY feature is ON, the unit will operate at a salt efficiency of 4000 grains of hardness removed per pound of salt. This mode of operation is the most efficient setting for salt usage, because the system will tend to recharge more often, with less salt usage. Turning the feature OFF will tend to lengthen the time between recharge cycles, which will provide the most efficient usage of water, but may use more salt. The degree of difference between these two cycles is highly dependent on the water usage and hardness at a particular installation.
Press the DOWN button again to display the Average Daily Gallons. ADG will appear in the display. This value is updated every night at midnight. Pressing the UP button will return the screen to the previous display.
SALT LEVEL
DAYS TO EMPTY
E
RECHARGE TONIGHT
To change the setting, press the UP or DOWN buttons to toggle the feature ON or OFF. Press the MODE button to accept. The display will move to SYSTEM/ELECTRONIC DIAGNOSTICS.
Press the DOWN button again to display the flow rate. GPM will appear in the display. This value is updated every 1⁄ 2 second. Pressing the UP button will return the screen to the previous display. Pressing the DOWN button will return the screen to the PRESENT TIME display.
%REM ADG GPM
DAYS TO EMPTY
SYSTEM/ELECTRONIC DIAGNOSTICS
E
SALT LEVEL
RECHARGE TONIGHT
This display contains system diagnostics information to assist in troubleshooting problems with the system. See page 18 for details. Press the MODE button to return to the normal run display.

If time is lost on the display due to power interruption, the blue indicator light will flash 4 times every second, until the present time of day is entered.
When the DAYS TO EMPTY drops to 15, the blue indicator light and DAYS TO EMPTY in the display will flash every second and the alarm will beep every 30 seconds (from 8:00 AM to 8:00 PM), to notify the user that the unit is running low on salt. As soon as any button is pressed, the alarm will stop beeping. The blue indicator light and DAYS TO EMPTY will continue to flash. Once salt is added to the brine tank and the SALT LEVEL is reset, the DAYS TO EMPTY will be reset.
If there is an error code detected, the blue indicator light will flash 4 times every second, the display will flash Err and the alarm will beep every 30 seconds (from 8:00 AM to 8:00 PM) to signal that the softener requires service. The alarm can be turned off by pressing any button, but the blue indicator light and display will continue to flash.
See page 18 for information to assist in troubleshooting error codes. Once the problem is corrected, disconnect the transformer from the wall outlet momentarily, and plug it back in. The normal display will appear. The motor may run for several minutes, as the unit resets. If the problem is not corrected, the error code will reappear in 6 minutes.
Steady blue light indicates that the unit is working correctly. The light flashes when the unit needs attention from the user.

To complete the installation, do the following sanitizing procedures.
water softener, and out the drain. This process takes approximately 2 hours.
Care is taken at the factory to keep your water softener clean and sanitary. Materials used to make the softener will not infect or contaminate your water supply and will not cause bacteria to form or grow. However, during shipping, storage, installation and operation, bacteria could get into the softener. For this reason, sanitizing as follows is suggested when installing.
NOTE: When the sanitizing recharge is over, all remaining bleach is flushed from the conditioner and your house COLD water supply is fully soft immediately. However, your water heater is filled with hard water and as hot water is used, it will refill with soft water. When all the hard water is replaced in the water heater, hot only and mixed hot and cold water will be fully soft. If you want totally soft water immediately, after the above recharge, drain the water heater until the water runs cold.
Rated Capacity* 11,700 grains with 13,300 grains with 2.3 lbs of salt 2.6 lbs of salt 30,800 grains with 35,500 grains with 8.5 lbs of salt 9.8 lbs of salt 39,000 grains with 45,100 grains with 14.7 lbs of salt 17.0 lbs of salt
33⁄8″
OUT
INLET– OUTLET
Rated Efficiency** 5,100 grains/lb. 5,120 grains/lb. @ 2.3 lbs. of salt @ 2.6 lbs. of salt
Amount of High Capacity Resin (lbs/cu. ft) 56.2/1.08 65.0/1.25
Resin Tank Nominal Size (in., dia. x height) 9 x 40 10 x 40
471⁄2″ 411⁄4″ 16″
Service Flow Rate (gpm) 10 9.5
Water Supply Maximum Hardness (gpg) 110 160
Water Supply Maximum Clear Water Iron (ppm)*** 5 12
Water Pressure Limits (min.–max. psi)**** 20–125 20–125
Pressure Drop at Rated Service Flow (psig) 14 10
Water Temperature Limits (min.–max. °F) 40–120 40–120
Maximum Flow Rate to Drain (gpm) 2.3 2.3
These systems conform to NSF/ANSI 44 for the specific capacity claims as verified and substantiated by test data. * Testing was performed using pellet grade sodium chloride as the regenerant salt. ** Efficiency rating is valid only at the lowest stated salt dosage. These softeners were efficiency rated according to NSF/ANSI 44. *** Extent of iron removal may vary with conditions. The capacity to reduce clear water iron is substantiated by WQA test data. State of Wisconsin requires additional treatment if water supply contains greater than 5 ppm clear water iron. Use of Diamond Crystal® Red•Out® or Super Iron Out® will improve iron removal. Refer to Cleaning Iron Out of the Water Softening System section. **** Canada working pressure limits: 1.4–7.0 kg/cm2.
19″

When the water softening system is providing soft water, it is called “Service.” During service, hard water flows from the house main water pipe into the water softening system. Inside the water softening system resin tank is a bed made up of thousands of tiny, plastic resin beads. As hard water passes through the bed, each bead attracts and holds the hard minerals. This is called ion-exchanging. It is much like a magnet attracting and holding metals. Water without hard minerals (soft water) flows from the water softening system and to the house pipes.
After a period of time, the resin beads become coated with hard minerals and they have to be cleaned. This cleaning is called recharge. Recharge is started at 2:00 AM (factory setting) by the water softening system control, and consists of five stages or cycles. These are FILL, BRINING, BRINE RINSE, BACKWASH and FAST RINSE.
For emergency needs, hard water is available to the home during the recharge cycles.
However, you should avoid using HOT water because the water heater will fill with the hard water.
Fill Salt dissolved in water is called brine. Brine is needed to clean the hard minerals from resin beads. To make the brine, water flows into the salt storage area during the fill stage.
Backwash During backwash, water travels up through the resin tank at a fast flow rate, flushing accumulated iron, dirt and sediments from the resin bed and to the drain.
Brining During brining, brine travels from the salt storage area into the resin tank. Brine is the cleaning agent needed to remove hard minerals from the resin beads. The hard minerals and brine are discharged to the drain.
Fast Rinse Backwash is followed by a fast flow of water down through the resin tank. The fast flow flushes brine from the bottom of the tank, and packs the resin bed.
After fast rinse, the water softening system returns to soft water service.
The nozzle and venturi create a suction to move the brine, maintaining a very slow rate to get the best resin cleaning with the least salt.
Brine Rinse After a pre-measured amount of brine is used, the brine valve closes. Water continues to flow in the same path as during brining, except for the discontinued brine flow. Hard minerals and brine flush from the resin tank to the drain.

About the water softener system.
Sometimes, a hard crust or salt bridge forms in the salt storage area. It is usually caused by high humidity or the wrong kind of salt. When the salt bridges, an empty space forms between the water and salt. Then salt will not dissolve in the water to make brine.

If the brine tank is full of salt, it is hard to tell if you have a salt bridge. Salt is loose on top, but the bridge is under it. The following is the best way to check for a salt bridge.
Salt should be loose all the way to the bottom of the tank. Take a broom handle or like tool, and carefully push it down into the salt, working it up and down. If the tool strikes a hard object (be sure it’s not the bottom or sides of the tank), it’s most likely a salt bridge. Carefully break the bridge with the tool. Do not pound on the walls of the tank.
If the wrong kind of salt made the bridge, take it out. Then fill the tank with nugget or pellet salt only. In humid areas, it is best to fill with less salt, more often to prevent a salt bridge from forming.
A clean nozzle and venturi is needed for the water softening system to work properly. This small unit makes the suction to move brine from the salt storage area to the resin tank during recharge. If it becomes plugged with sand, dirt, etc., the water softening system will not work and you will get hard water.

To get to the nozzle and venturi, remove the water softening system top cover. Be sure the water softening system is in service cycle (no water pressure at nozzle and venturi). Then, while holding the nozzle and venturi housing with one hand, remove the cap. Lift out the screen support and screen, then the nozzle and venturi. Wash and rinse the parts in warm water until clean. If needed, use a small brush to remove iron or dirt. Also check and clean the gasket.
Carefully replace all parts in the correct order. Lightly lubricate the o-ring seal with clean silicone grease or petroleum jelly and place in position. Install and tighten the cap, by hand only. Do not overtighten the cap.

During normal operation, the present time of day and AM or PM and DAYS TO EMPTY show in the control display area. When the demand computer determines a recharge is needed, RECHARGE TONIGHT begins to flash in the display along with the present time. RECHARGE TONIGHT flashes until the next recharge start time, then changes to RECHARGE, which flashes until the recharge is over.
Sometimes, a manually started recharge may be desired or needed. Two examples:
RECHARGE TONIGHT Touch (do not hold) the RECHARGE button. RECHARGE TONIGHT flashes in the control display area. A recharge will occur at the next preset recharge start time. If you decide to cancel this recharge, touch the same button once more.
I You have used more water than usual (house
guests, extra washing, etc.) and you may run out of soft water before the next recharge.
I The system ran out of salt.
Use one of the following features to start a recharge immediately, or at the next preset recharge start time.
RECHARGE Press and hold the RECHARGE button until RECHARGE starts to flash in the control display area. The water softening system begins an immediate recharge and, when over in about two hours, you will have a new supply of soft water. Once started, you cannot cancel this recharge.
If electrical power to the water softening system is interrupted, the control display is blank, and the blue indicator light is off, but the control keeps correct time for about 6 hours. When power is restored, you have to reset the present time only if the display and blue indicator light are flashing. All other settings are maintained and never require resetting unless a change is desired.
If the time is flashing after a long power outage, the water softening system continues to work as it should to provide you with soft water. However, recharge may occur at the wrong time of day until you reset the control to the correct time of day.
The control computer has a self-diagnostic function for the electrical system (except input power and water meter). The computer monitors the electronic components and circuits for correct operation. If a malfunction occurs, an error code appears in the control display.
The chart on Error Codes shows the error codes that could appear and possible reasons for each code. See Manually Initiated Electronics Diagnostics to further isolate the defect.

About the water softener system.
ERROR CODE DISPLAYED ERR 01 ERR 02 ERR 03 ERR 04 ERR 05
To remove an error code: 1. Unplug transformer.
If you are not getting soft water, and an error code is not displayed, use the procedures below to find the problem. First make the following visual checks.
If you do not find a problem with the visual checks, continue below.
CONTROL SHOWS WRONG TIME AND DAY, AND/OR IS FLASHING.
Electrical power was off. Reset the correct time of day.
Investigate reason for power loss.
Check electrical power to control (outlet, transformer, power cable, all connections).
Do manual diagnostics to verify proper function.
CONTROL DISPLAY BLANK.
CONTROL DEFECTIVE
CONTROL DISPLAY SHOWS CORRECT TIME AND DAY AND IS STEADY.
Do manual diagnostics.

– If there is no reading in the display, with faucet open,
check the sensor. Pull the sensor from the valve outlet port, and pass a small magnet in front of the sensor. Counter should index in the display. If counter does not index, check to make sure harness is connected to board properly. If there is a reading in the display, there may be a problem associated with the turbine. Turn off water supply, close the bypass valve and disconnect bypass valve from body. Check turbine for binding or restriction due to debris. If this does not correct the problem, the Timer, Sensor or Turbine may require replacement.
3. OPERATION OF DIAGNOSTICS
– Closed – valve rotating to next position
– Open – valve in position, service, fill, brine, etc.
Turbine support and shaft
– 000 indicates no water is flowing through the valve
– Open nearby soft water faucet
– 000 to 141 (continual) shows water is flowing. Display
repeats for each gallon of water passing through the meter. Control will beep at every gallon.

About the water softener system.
If the water softening system does not draw brine, check:
I nozzle and/or venturi dirty or defective. I defective nozzle and venturi seal. I nozzle and venturi not seated properly
on gasket. I other inner valve defect (rotor seal, rotor and
disc, wave washer, etc.). I restricted drain (check drain fitting and
hose).

Brine (salt dissolved in water) is needed for each and every recharge. The water for making brine is metered into the salt storage area by the water softening system valve and control. However, you must keep the tank supplied with salt.
Use clean water softening salts only, at least 99.5% pure. NUGGET, PELLET or coarse SOLAR salts are recommended. Do not use rock, block, granulated or ice cream making salts. They contain dirt and sediments, or mush and cake, and will create maintenance problems.
When to refill with salt: If the blue indicator light and DAYS TO EMPTY are flashing, there is less than 15 days supply of salt. Refill with salt. In humid areas it is best to refill with less salt and more often, to avoid the forming of a salt bridge (see page 16). After adding salt, remember to reset the SALT LEVEL in the control (see page 11). Never allow the salt level to drop below zero on the yellow indicator before you refill it. Without enough salt, you will soon have hard water.
CAUTION: Water softening salt with iron removing additives: Some salts may have an additive to help the water softening system handle iron in the water supply. Although this additive may help to keep the water softening system resin clean, it may also release corrosive fumes that weaken and shorten the life of some water softening system parts. GE recommends using only Diamond Crystal® Red•Out® brand salt.
Your water softening system takes hardness minerals (calcium and magnesium) out of the water. Also, it can control some (see the Specification Guidelines section) “clear water” iron. With clear water iron, water from a faucet is clear when first put into a glass. After 15 to 30 minutes, the water begins to cloud or turn rust colored. A water softening system will not remove any iron that makes the water cloudy or rusty as it comes from the faucet (called red water iron). To take red water iron out of water, or over the maximum of clear water iron, an iron filter or other equipment is needed.
IMPORTANT: It is important to mix the resin bed cleaner with water (following the manufacturer’s instructions), pour it into the brinewell tube (see page 5) and recharge the softener immediately. Do not pour the resin bed cleaner in with the salt, as it will not be as effective in cleaning the resin, and can cause damage to the softener if it is left in the brine tank for an extended period due to the corrosive gases that are formed.
GE recommends using only Diamond Crystal® Red•Out® brand salts with Iron Fighter® additive to help keep the resin bed clean of clear iron. If your water supply has clear water iron, periodic resin bed cleaning is needed. GE recommends using Super Iron Out® brand resin bed cleaner to thoroughly clean your resin bed if your iron content is high. Clean the bed at least every six months, or more often if iron appears in the soft water between cleanings.

Troubleshooting Tips Save time and money! Review the chart on this page first and you may not need to call for service.
No soft water Faucet or fixture where sample was • To conserve salt, the installer may have isolated some fixtures taken not plumbed to soft water. (outside faucets, toilets, etc.) from soft water. From the outlet NOTE: Be sure sample is from a faucet of the water softening system, trace the water flow path, that does not mix soft and hard water. in house plumbing. If soft water is not directed to a faucet For example, a single lever kitchen faucet, or fixture where wanted, consult a plumber. if the cold side is plumbed to hard water.
No salt in the brine tank or • Check for a salt bridge or, if the tank is empty, refill with salt bridged recommended salt. Press (for 3 seconds) the RECHARGE button to start an immediate recharge and restore soft water supply.
Transformer unplugged at wall outlet or • Check for a loss of electrical power to the water softening power cable to softener not connected. system, due to any of these conditions and correct as needed. Fuse blown or circuit breaker popped With the power supply restored, observe the faceplate time on circuit to electrical outlet. display and read Programming the Control section. Electrical outlet on a circuit that can NOTE: The electrical outlet for the softener should be continuously be switched off live so it cannot be accidentally switched off.
Manual bypass valve in bypass position • Be sure the bypass valve stem is positioned properly, with the
knob in the OUTposition. Observe instructions on the decal at the end of the stem.
Valve drain hose pinched, plugged, • Any restriction in this drain hose may prevent proper elevated too high or otherwise operation of the nozzle and venturi and reduce or prevent restricted brine draw during recharge.
Nozzle and venturi dirty, incorrectly • Refer to Cleaning the Nozzle and Venturi Assembly instructions. assembled or damaged With water pressure to the water softening system off, take the nozzle assembly apart. Inspect, clean and replace as needed. Any foreign particle(s), scratches, nicks, etc., in the passages can prevent operation. Be sure holes in the gasket are centered over holes in the housing.

Water hard sometimes Using hot water while the water • Avoid using hot water during water softening system softening system is regenerating recharge because the water heater will refill with hard water. See Automatic Hard Water Bypass During Recharge section, page 15.
Control HARDNESS number setting • Press the MODE button until arrow points to HARDNESS. too low Be sure the number shown is the same as the actual grains per gallon hardness of your water supply. See the Programming the Control section if a change in the setting is needed.
Grains of hardness in your water • Water hardness can change over time, especially in well water. supply have increased To check, have the water tested by a water analysis laboratory or call your local water department. Adjust the HARDNESS number setting as needed.
Water feels slippery Absence of hardness minerals • This is normal. Hardness in water gives it the abrasive feel after installation of you may have been accustomed to. The slippery feel is the water softening system clean feel of soft water.
Water softening system Water softening system is a • Does not use much salt to regenerate—very efficient. not using any salt “demand” unit
Possible salt bridge • See the About the Water Softener System section, page 16.
Possible plugged nozzle and venturi • See the About the Water Softener System section, page 16.
Water is blue color Acidic water in copper plumbing • Have the water tested at once. after water softening system was installed
No power to unit • Check the circuit breaker or fuses.
Mechanical defect • Call for service.
Cloudiness on glassware Combination of soft water and • This is called etching and is permanent. To prevent this (automatic dishwashers) too much detergent from happening, use less detergent if you have soft water. Wash glassware in the shortest cycle that will get them clean.
Excessive/high level Valve drain hose pinched, • Any restriction in this drain hose may prevent proper of water in brine tank plugged, elevated too high operation of the nozzle and venturi and reduce or prevent or otherwise restricted brine draw during recharge.
Nozzle and venturi dirty, incorrectly • See the Cleaning the Nozzle and Venturi Assembly section, assembled or damaged page 16. With water pressure to the water softening system off, take the nozzle assembly apart. Inspect, clean and replace as needed. Any foreign particle(s), scratches, nicks, etc., in the passages can prevent operation. Be sure holes in the gasket are centered over holes in the housing.

Low water pressure Check pressure. • Drain height 8′ or less, pressure should be minimum of 20 psi.
Restricted drain hose • Clean and reconnect hose.
Brown/yellow Unit was idle for a period of time • Complete the Sanitization Procedures on page 14. colored water
Resin beads showing Cracked distributor • Call for service. up in drinking water and sink
Sounds you might hear Running water from the unit • This is normal. into a drain during recharge
Water has air bubbles Air in system after installation • Will go away after it runs for a while. and is cloudy
When power applied Control needs to be programmed • See the Programming the Control section, page 10. to the system (a power outage may have occurred)
If “Err” in display Electrical problem with system • See page 18 for details.





Parts list.


G G X N S S H H 3 4 9 5 E E
REF. NO. GE PART NO. PART DESCRIPTION (03) (03)
0002 WS31X10018 BACK COVER, ELECTRONICS 1 1 0003 WS35X10001 O-RING SEAL KIT 1 1 0004 WS34X10016 DECAL, FACEPLATE 1 1 0005 WS07X10004 HOSE, DRAIN, 20 FT. 1 1 0007 WS14X10002 DISTRIBUTOR, TOP 1 1 0008 WS14X10001 DISTRIBUTOR, BOTTOM 1 1 0009 WS01X10009 RESIN, 1-CU. FT. 1 1 0010 WS32X10011 RESIN TANK 9X40 1 0010 WS32X10018 RESIN TANK 10X40 1 0011 WS31X10022 COVER, TOP W/ LENS 1 1 0012 WS31X10023 FACEPLATE 1 1 0013 WS21X10016 CONTROL 1 1 0016 WS26X10013 TRANSFORMER WITH POWER CORD 1 1 0017 WS31X10021 COVER, SALT HOLE, WITH LABELS 1 1 0018 WS33X10001 VAPOR BARRIER 1 1 0019 WS33X10007 RIM 1 1 0020 WS31X10024 COVER, BRINEWELL W/ DECAL 1 1 0021 WS02X10009 NUT 1 1 0022 WS32X10017 BRINEWELL W/ DECAL 1 1 0023 WS02X10027 SCREW 1 1 0024 WS32X10016 TANK, BRINE, ROUND 1 1 0025 WS18X10003 CLAMP, HOSE 2 2 0026 WS22X10016 ADAPTER, HOSE 1 1 0027 WS22X10017 GROMMET 1 1 0028 WS35X10035 GROUND CLAMP KIT 1 1 0029 WS15X10035 BRINE VALVE ASM. 1 1 0030 WS35X10036 FLOAT, STEM & GUIDE 1 1 0031 WS03X10006 CLIP 1 1 0032 WS15X10006 VALVE BODY, BRINE 1 1 0033 WS03X10007 CLIP 1 1 0034 WS03X10008 SCREEN 1 1 0035 WS07X10002 TUBING ASM. 1 1 0036 WS07X10015 BRINE TUBE ASM. 1 1 0038 WS02X10029 SPACER 1 1 0039 WS02X10030 FACEPLATE SUPPORT 1 1 0055 WS28X10003 RETAINER CLAMP 2 2 0056 WS28X10007 CLAMP 2 2 0101 WS02X10023 SCREW 2 2 0103 WS21X10003 SWITCH 1 1 0105 WS02X10024 SCREW 8 8 0106 WS31X10013 COVER, VALVE 1 1 0107 WS03X10034 WAVE SPRING 1 1 0108 WS26X10010 ROTOR & DISC ASM. 1 1 0109 WS19X10004 CAP, VENTURI 1 1 0110 WS03X10011 SEAL, O-RING 5 5

Parts catalog.
G G X N S S H H 3 4 9 5 E E
REF. NO. GE PART NO. PART DESCRIPTION (03) (03)
0111 WS19X10005 SUPPORT SCREEN 1 1 0112 WS03X10013 SCREEN 1 1 0113 WS22X10034 FLOW PLUG, .10 GPM 1 0113 WS22X10036 FLOW PLUG, .15 GPM 1 0114 WS08X10006 GASKET & ASPIRATOR 1 0114 WS08X10007 GASKET & ASPIRATOR 1 0115 WS03X10015 CONE SCREEN 1 1 0116 WS22X10021 PLUG, FILL FLOW .30 GPM 1 1 0117 WS03X10017 FERRULE NUT 1 1 0118 WS15X10034 NOZZLE/VENTURI BODY 1 1 0119 WS03X10018 RETAINER 1 1 0120 WS03X10019 SEAL, O-RING 1/4″ X 3/8″ 2 2 0121 WS15X10025 BODY, VALVE 1 1 0122 WS03X10020 SPRING 1 1 0123 WS22X10029 PLUG, DRAIN SEAL 1 1 0124 WS15X10027 NOZZLE/VENTURI ASM. 1 0124 WS15X10036 NOZZLE/VENTURI ASM. 1 0125 WS03X10043 WAVE SPRING BEARING 1 1 0130 WS35X10020 SEAL KIT, 1″ 1 1 0132 WS22X10058 ADAPTER, DRAIN HOSE 1 1 0135 WS03X10033 CLIP 1 1 0136 WS26X10008 CAM & GEAR 1 1 0137 WS26X10009 BEARING 1 1 0138 WS26X10007 PLATE, MOTOR 1″ 1 1 0139 WS02X10028 SCREW, #6-20 X 3/8″ 3 3 0140 WS26X10011 MOTOR ASM. 1 1 0141 WS02X10016 SCREW, #6-20 X 7/8″ 2 2 0143 WS60X10011 ADAPTER–NPT THREAD–1″ VALVE 2 2 0145 WS60X10008 CLIP 4 4 0146 WS28X10018 HARNESS WIRE, SENSOR ASSY., 1″ 1 1 0147 WS19X10008 TURBINE SUPPORT 1 1 0148 WS19X10009 TURBINE 1 1 0150 WS03X10024 SEAL, O-RING 1 1 0151 WS15X10026 BYPASS ASM. 1 1 0998 WS35X10049 INSTALLATION KIT 1 1 0999 49-50180-1 OWNER’S MANUAL 1 1

All warranty service provided by our SmartWater™Authorized Servicer Network. To schedule service, call 800.952.5039 (U.S.) or 866.777.7627 (Canada). Please have serial number and model number available when calling for service.
Staple your receipt here. Proof of the original purchase date is needed to obtain service
under the warranty.
One Year Any part of the Water Softening System which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor and related original purchase service to replace the defective part.
Three Years The electronic monitor, if it fails due to a defect in materials or workmanship. During this From the date of the three-year limited warranty, you will be responsible for any labor or related service costs. original purchase
Ten Years A replacement brine tank or cabinet, if either fails due to a defect in materials or workmanship. From the date of the During this ten-year limited warranty, you will be responsible for any labor or related service costs. original purchase
I Service trips to your home to teach you how to use
I Replacement of house fuses or resetting of circuit breakers.
the product.
I Damage to the product caused by accident, fire, floods or
I Improper installation, delivery or maintenance.
acts of God.
I Failure of the product if it is abused, misused, altered, used
I Incidental or consequential damage caused by possible
commercially or used for other than the intended purpose.
defects with this appliance, its installation or repair.
I Use of this product where water is microbiologically unsafe
I Product not accessible to provide required service.
or of unknown quality, without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

All warranty service provided by our Factory Service Centers or an authorized technician. For service, call toll free 1.866.777.7627. Please have serial number and model number available when calling for service.
One Year Any part of the Water Softening System which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor and related original purchase service to replace the defective part.
Three Years The electronic monitor, if it fails due to a defect in materials or workmanship. During this From the date of the three-year limited warranty, you will be responsible for any labor or related service costs. original purchase
Ten Years A replacement brine tank or cabinet, if either fails due to a defect in materials or workmanship. From the date of the During this ten-year limited warranty, you will be responsible for any labor or related service costs. original purchase
I Service trips to your home to teach you how to use
I Replacement of house fuses or resetting of circuit breakers.
the product.
I Damage to the product caused by accident, fire, floods or
I Improper installation, delivery or maintenance.
acts of God.
I Failure of the product if it is abused, misused, altered, used
I Incidental or consequential damage caused by possible
commercially or used for other than the intended purpose.
defects with this appliance, its installation or repair.
I Use of this product where water is microbiologically unsafe
I Product not accessible to provide required service.
or of unknown quality, without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within Canada. In-home warranty service will be provided in areas where it is available and deemed reasonable by Mabe to provide.
WARRANTOR IS NOT RESPONSIBLE FOR CONSEQUENTIAL DAMAGES.
Warrantor: MABE CANADA INC.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.