Page 1 of the GE GNSH45E user manual — 7283950 215C1173P025 49-50180-1 12-06 JR
Page 1 · click to enlarge
Page 1

ge.com

Water Softening system

Safety Information 2

Water Softening

Installation Instructions. . .3–14 Step-by-step instructions 6–14

System

Operating Instructions Breaking a salt bridge 16 Cleaning the nozzle and venturi assembly 16 Features 17 Service 15, 18–20 Water softener system 15–20

Owner’s Manual & Installation Instructions

Sistema Suavizante

Care and Cleaning 21

de Agua

Troubleshooting Tips 22–24

Manual del Propietario e Instrucciones de Instalación

Consumer Support Consumer Support Back Cover Parts list/catalog 27–30 Warranty (U.S.) 31 Warranty (Canada) 32

La sección en español empieza en la página 33

System tested and certified by NSF International against NSF/ANSI Standard 44 for the chemical reduction claims specified on the performance data sheet.

Sistema probado y certificado por NSF International contra norma 44 de NSF/ANSI para las afirmaciones de reducción de los productos químicos especificadas en la hoja de datos de funcionamiento.

Write the model and serial numbers here:

To find these numbers, lift the cover and look on the rim below the control panel.

7283950 215C1173P025 49-50180-1 12-06 JR

Show 4 more labels / short text on this page
Models GXSH39E, GNSH45E · Modelos GXSH39E, GNSH45E · Model # ________________ · Serial # ________________
Page 2 of the GE GNSH45E user manual — READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS
Page 2 · click to enlarge
Page 2

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of electric shock, property damage or personal injury.

SAFETY PRECAUTIONS

I Check and comply with your state and local codes.

I Use clean water softening salts only, at least 99.5%

You must follow these guidelines.

pure. NUGGET, PELLET or coarse SOLAR salts are recommended. Do not use rock, block, granulated or ice cream making salts. They contain dirt and sediments, or mush and cake, and will create maintenance problems.

I Use care when handling the water softening

system. Do not turn upside down, drop, drag or set on sharp protrusions.

I Water softening systems using sodium chloride

I Keep the salt hole cover in place on the softener

(salt) for recharge add sodium to the water. Persons on sodium restricted diets should consider the added sodium as part of their overall intake. Potassium chloride can be used as an alternative to sodium chloride in your softener.

unless servicing the unit or refilling with salt.

I The water softening system works on 24 volt-60 Hz

electrical power only. Be sure to use only the included transformer.

I Transformer must be plugged into an indoor

120 volt, grounded outlet only.

PROPER INSTALLATION

This water softening system must be properly installed and located in accordance with the Installation Instructions before it is used.

I Install or store where it will not be exposed to

I Softener resins may degrade in the presence of

temperatures below freezing or exposed to any type of weather. Water freezing in the system will break it. Do not attempt to treat water over 100°F.

chlorine above 2 ppm. If you have chlorine in excess of this amount, you may experience reduced life of the resin. In these conditions, you may wish to consider purchasing a GE point-of-entry household filtration system with a chlorine reducing filter.

I Do not install in direct sunlight. Excessive sun or

heat may cause distortion or other damage to non-metallic parts.

I Properly ground to conform with all governing

codes and ordinances.

I Use only lead-free solder and flux for all

sweat-solder connections, as required by state and federal codes.

I The water softening system requires a minimum

water flow of three gallons per minute at the inlet. Maximum allowable inlet water pressure is 125 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. Use a pressure reducing valve to reduce the flow if necessary.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS

Page 3 of the GE GNSH45E user manual — IMPORTANT INSTALLATION RECOMMENDATIONS
Page 3 · click to enlarge
Page 3

Installation Water Softening System Instructions Models GXSH39E and GNSH45E

Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com

  • Check with your state and/or local public works department for plumbing codes. You must follow their guides as you install the Water Softening system.

BEFORE BEGINNING INSTALLATION

IMPORTANT INSTALLATION RECOMMENDATIONS (CONT.)

Read these instructions completely and carefully.

  • IMPORTANT — Save these instructions for local inspector’s use.
  • Use care when handling the softener. Do not turn upside down, drop, drag or set on sharp protrusions.
  • IMPORTANT — Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the Warranty.
  • A shutoff valve must be available or added near the installation point.
  • Maximum allowable inlet water pressure is 125 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. Use a pressure reducing valve if necessary. (Adding a pressure reducing valve may reduce the flow.)
  • The softener works on 24 volt-60 Hz electrical power only. Be sure to use the included transformer. Be sure the electric outlet and transformer are in an inside location to protect from moisture.
  • See Where to Install the Softener section for more details.

IMPORTANT INSTALLATION RECOMMENDATIONS

  • In the Commonwealth of Massachusetts, Plumbing Code 248 CMR shall be adhered to. Consult with your licensed plumber.
  • Small parts remaining after the installation could be a choke hazard. Discard safely.
  • Use only lead-free solder and flux for all sweatsolder connections, as required by state and federal codes.
  • Connect the softener to the main water supply pipe before or ahead of the water heater. DO NOT RUN HOT WATER THROUGH THE SOFTENER. Temperature of water passing through the softener must be less than 120°F.
Page 4 of the GE GNSH45E user manual — TOOLS AND MATERIALS REQUIRED FOR INSTALLATION
Page 4 · click to enlarge
Page 4

UNPACKING AND INSPECTION

WHERE TO INSTALL THE SOFTENER

Be sure to check the entire softener for any shipping damage or parts loss. Also note damage to the shipping cartons. Contact the transportation company for all damage and loss claims. The manufacturer is not responsible for damages in transit.

  • Place the softener as close as possible to a sewer drain, or other acceptable drain point or standpipe.
  • It is recommended to keep outside faucets on hard water to save soft water and salt.
  • Do not install the softener in a place where it could freeze. Freeze damage is not covered by the warranty.

Small parts needed to install the softener are packaged either in a bag or on a cardboard sheet. To avoid loss of the small parts, keep them packaged until you are ready to use them. Be sure not to discard components hidden in packaging.

  • Do not install the softener where it would block access to the water heater or access to the main water shutoff.
  • Put the softener in a place where water damage is least likely to occur if a leak develops. The manufacturer will not repair or pay for water damage.

TOOLS AND MATERIALS REQUIRED FOR INSTALLATION

  • Pliers
  • A 120-volt electric outlet is needed to plug in the included transformer. The softener has a 10-foot power cable. If the outlet is remote (up to 100 feet), use 18 gauge wire to connect. Be sure the electric outlet and transformer are in an inside location, to protect from wet weather. Be sure the outlet is unswitched to prevent accidental shutoff.
  • Screwdriver
  • Teflon tape
  • Razor knife
  • Two adjustable wrenches
  • Additional tools may be required if modification to home plumbing is necessary.
  • If installing in an outside location, you must take the steps necessary to assure the softener, installation plumbing, wiring, etc., are as well protected from the elements (sunlight, rain, wind, heat, cold), contamination, vandalism, etc., as when installed indoors. Outdoor installation is not recommended, and voids the warranty.
  • In and out fittings included with the softener are 1 ″ NPT male adapters. You should maintain the same, or larger, pipe size as the water supply pipe, up to the softener inlet and outlet. Then, use the necessary adapters to connect the water supply to the 1 ″ NPT male adapters.
  • Use the included bypass valve to install the softener. The bypass valve allows you to turn off water to the softener for servicing, but still have water in the house pipes. The in and out fittings referred to above connect to the bypass valve with the included bypass clips.
  • Keep the softener out of direct sunlight. The sun’s heat may distort non-metallic parts and may damage the electronics.
  • Use appropriate fitting/pipe material (i.e., copper, brass, galvanized or CPVC) to connect the 1 ″ NTP plastic adapters to the house plumbing.
  • If additional drain hose is needed for valve and salt tank drains, it can be ordered from GE Parts at 800.626.2002, part number WS07X10004.
  • If a rigid valve drain is needed to comply with plumbing codes, you can buy the parts needed to connect a 1/2 ″ copper tubing or plastic pipe drain. See Step 5 .
  • Clean nugget or pellet water softener salt is needed to fill the brine tank. See Step 9 .
Page 5 of the GE GNSH45E user manual — Installation Instructions
Page 5 · click to enlarge
Page 5
PLAN HOW YOU WILL INSTALL THE WARNING: Use only lead-free solder and SOFTENER flux to prevent lead poisoning. You must first decide how to run in and out pipes See Typical Installation Illustration. Use this as a guide to the softener. Look at the house main water pipe when planning your particular installation. Be sure at the point where you will connect the softener. to direct the incoming hard water supply to the Is the pipe soldered copper, glued plastic or softener valve inlet fitting. The valve is marked threaded galvanized? What is the pipe size? IN and OUT. TYPICAL INSTALLATION ILLUSTRATION OPTIONAL 3-VALVE BYPASS INSTALLATION ILLUSTRATION Soft water Hard water Soft water to outside Hard faucets M A IN W A T E R P IP E M A IN W A T E R P IP E water 24V 120-volt Hard 24V Hard transformer outlet water to transformer Inlet water 1″ female outside Bypass 120-volt valve Clips adapter (2) faucets valve outlet (not supplied) Outlet valve 1″ NPT male 1″ female adapter adapter (2) (2) (not supplied) O-rings (2) Salt hole Salt cover Clips (2) hole 1″ NPT male INLET cover adapter (2) O-rings (2) O-rings (2) INLET Clips (2) 3-Valve Bypass SALT SALT Brinewell System GOES HERE NOTE: See Drain GOES For soft water HERE Hose Connections service: Brinewell section. • Open the inlet and outlet valves • Close the Fig. 2 bypass valve Fig. 1 CROSSOVER CROSSOVER For bypass hard Use if water supply flows Use if water supply flows water: from the left. Include single from the left. Include single • Close the inlet or 3-valve bypass. or 3-valve bypass. and outlet valves Hard Hard • Open the water water bypass valve Soft Soft water water From softener To softener From outlet To softener inlet softener outlet inlet TYPICAL INSTALLATION ILLUSTRATION Soft water M A IN W A T E R P IP E Hard water 24V 120-volt Hard transformer outlet water to 1″ female outside Clips adapter (2) faucets (not supplied) 1″ NPT male adapter (2) O-rings (2) Salt hole cover Clips (2) INLET O-rings (2) SALT GOES HERE NOTE: See Drain Hose Connections Brinewell section. Fig. 1 CROSSOVER Use if water supply flows from the left. Include single or 3-valve bypass. Hard water Soft water From softener To softener outlet inletOPTIONAL 3-VALVE BYPASS INSTALLATION ILLUSTRATION Hard water M A IN Soft water to outside faucets W A T E R P IP E 4V Hard ransformer Inlet water Bypass 120-volt valve valve outlet Outlet valve 1″ female adapter (2) (not supplied) Salt hole 1″ NPT male cover adapter (2) O-rings (2) INLET Clips (2) 3-Valve Bypass SALT Brinewell System GOES For soft water HERE service: • Open the inlet and outlet valves • Close the Fig. 2 bypass valve CROSSOVER For bypass hard Use if water supply flows water: from the left. Include single • Close the inlet or 3-valve bypass. and outlet valves Hard • Open the water bypass valve Soft water From To softener softener outlet inlet
Page 6 of the GE GNSH45E user manual — SIDE VIEW
Page 6 · click to enlarge
Page 6

BEFORE YOU BEGIN

INSTALL DRAIN FITTING

  • Turn off the gas or electric supply to the water heater, in the possibility that the water heater may be drained while draining pipes.
  • Push the drain fitting (lubricate o-ring seals with silicone grease) into the part of the valve as shown.
  • Turn off the water supply to pipes to be cut and drain the house water pipes.
  • Snap the large plastic clip in place, from the top down as shown. Be sure the clip snaps into place. Pull on the drain fitting to make sure it is held securely in place.
  • Open both hot and cold faucets at the lowest location possible.

INSTALL BYPASS VALVE

  • Remove plastic shipping plug and wire from valve outlet.

Turbine Valve outlet Turbine shaft and support

MOVE THE SOFTENER ASSEMBLY INTO INSTALLATION POSITION

Before sliding softener in position, be sure the installation surface is level and smooth. Sharp objects under the tank may puncture it. If needed, place the tank on a section of 3/4″ thick (minimum) plywood. Then, place shims under the plywood as needed to level the softener. Slide softener into position.

  • Push the bypass valve (lubricate o-ring seals with silicone grease) into both ports of the valve as shown.

O-ring seal goes into the outer groove only. The clip snaps into the inner groove (see below).

  • Snap the 2 large plastic clips in place, from the top down, as shown.

SIDE VIEW

END VIEW

Bypass valve (push all the way in)

Valve body inlet or outlet

  • Push the NPT adapters (lubricate o-ring seals with silicone grease) into both ports of the valve as shown
  • Snap the 2 large plastic clips in place, from the side, as shown.
Show 5 more labels / short text on this page
Drain fitting · Clips · O-rings · NPT adapter · Clip
Page 7 of the GE GNSH45E user manual — OUT
Page 7 · click to enlarge
Page 7

PLUMB “IN” AND “OUT” PIPES TO AND FROM SOFTENER CAUTION: Observe all of the following cautions as you connect inlet and outlet plumbing. See Typical Installation Illustration.

CONNECT AND RUN THE VALVE DRAIN HOSE

  • Use the provided drain hose (20 ′ length included) to attach to the valve drain fitting. To keep water pressure from blowing the hose off, use supplied spring clamp to secure in place. Cut the necessary length and use the remainder in Step 6.
  • BE SURE INCOMING HARD WATER SUPPLY IS DIRECTED TO THE SOFTENER VALVE INLET PORT. If house water flow is from the left, use a plumbing crossover as shown in Typical Installation Illustration. If house water flows up from the floor level, turn the bypass valve upside down as shown.

1/4″ NPT thread

Barbs for 3/8″ I.D. tubing

Turn bypass valve upside down to connect to floor level plumbing

  • Locate the other end of the hose at a suitable drain point (floor drain, sump, laundry tub, etc.) that terminates at the sewer. Check and comply with local codes.

OUT

IN

  • With the softener in place, determine the correct length of piping required to connect the household plumbing to the NPT male adapter.
  • Remove softener from installation space.
  • If making a soldered copper installation, do all sweat soldering before connecting pipes to the NPT adapters and bypass valve. Torch heat will damage plastic parts.
  • Tie or wire the hose in place at the drain point. High water pressure will cause it to whip during the back-wash and fast rinse cycles of recharge. Also provide an air gap of at least 1-1/2 ″ between the end of the hose and the drain point. An air gap prevents possible siphoning of sewer water into the softener, if the sewer should “back-up.”
  • When turning threaded pipe fittings onto plastic fittings, use care not to cross-thread.
  • Use Teflon Tape on all external pipe threads.
  • Support inlet and outlet plumbing in some manner (use pipe hangers) to keep the weight off of the valve fittings.
  • Slide softener back into position.
  • Make final connections to the bypass valve and snap clips into place.

Be sure the clips for the bypass valve and NPT adapters snap into place. Pull on the bypass valve and NPT adapters to make sure the parts are held securely in place.

Hose clamp · Drain hose

Page 8 of the GE GNSH45E user manual — FLOOR DRAIN
Page 8 · click to enlarge
Page 8
GE GNSH45E — Step-by-step instructions diagram (page 8)
Fig. 1 · Step-by-step instructions

CONNECT AND RUN THE VALVE DRAIN HOSE (CONT.)

  • Elevating the drain hose may cause back pressure that could reduce the brine draw during recharge. If raising the drain line overhead is required to get to the drain point, measure the inlet water pressure to the softener first. For inlet pressures between 20 and 50 psi, do not raise higher than 8 ′ above the floor. For inlet pressure above 50 psi, the drain line may be raised to a maximum height of 14 ′ .
  • Insert the rubber grommet into the 3/4 ″ diameter hole in the brine tank sidewall as shown.
  • Push the end of the hose adapter elbow into the grommet as shown.
  • Attach a length of hose (use remaining hose from Step 5) to the hose adapter elbow. Use a hose clamp to hold it in place.
  • Locate the other end of the hose at the drain point. DO NOT ELEVATE this hose higher than the elbow on the brine tank.

STANDPIPE

Drain fitting on valve

LAUNDRY TUB

Tie or wire hose in place

SUMP

11⁄2″ air gap

FLOOR DRAIN

CONNECTING A RIGID VALVE DRAIN TUBE

To adapt a copper drain tube to the softener, buy a compression fitting (1/4 NPT x 1/2″ O.D. tube) and needed tubing from your local hardware store.

1/4″ NPT thread

Compression fitting 1/4 NPT x 1/2″ O.D. tube (not provided)

Cut barbs from valve drain elbow (pull clip and remove drain valve elbow from valve)

1/2″ outside diameter copper tube (not provided)

Show 5 more labels / short text on this page
Blue indicator light · Valve drain hose · Clamp · Clip · Barbs
Page 9 of the GE GNSH45E user manual — ADD WATER AND SALT TO THE BRINE TANK
Page 9 · click to enlarge
Page 9

INSTALL GROUNDING CLAMP DANGER: Failure to properly attach ground clamp could result in electrical shock.

FLUSH PIPES, EXPEL AIR FROM SOFTENER AND TEST YOUR INSTALLATION FOR WATER LEAKS (CONT.)

If plumbing is metal, to maintain electrical ground continuity in the house cold water piping, install the included ground clamp as shown.

  • Place bypass valve in the “service” position EXACTLY as follows. KEEP SOFT WATER FAUCETS OPEN.
  • Clean pipe with emery paper in the area where the clamp is to be installed.

SLOWLY pull or slide the valve stem (out) toward the service position, pausing several times to allow the softener to pressurize slowly.

  • Install grounding clamps as shown, making sure clamps fit freely around pipe.
  • After about 3 minutes, open a HOT water faucet for 1 minute, or until all air is expelled, then close. NOTE: If water appears cloudy or has salty taste, allow to run for several more minutes, or until clear.
  • Make sure lock washer is in place.
  • Handtighten screw, then one more full turn with screwdriver.
  • Close all water faucets.
  • Check your plumbing work for leaks and fix right away if any are found. Be sure to observe previous caution notes.
  • Turn on the gas or electric supply to the water heater. Light the pilot, if applicable.

ADD WATER AND SALT TO THE BRINE TANK

  • Lift the salt hole cover. Add about 3 gallons of water into the tank. Do not add into the brinewell.
  • Fill tank with NUGGET, PELLET or coarse SOLAR water softener salt with a purity of 99.5% or higher. Do not use rock, block, granulated and ice cream-making salts, or salt with iron-removing additives (except for Diamond Crystal ® Red
  • Out ® brand salt). Maximum salt storage capacity is approximately 200 lbs. Keep the salt hole cover closed unless servicing the unit or refilling with salt.

FLUSH PIPES, EXPEL AIR FROM SOFTENER AND TEST YOUR INSTALLATION FOR WATER LEAKS CAUTION: To avoid water or air pressure damage to softener inner parts, be sure to do the following steps in exact order.

  • Fully open 2 cold soft water faucets nearby the softener.
  • Place bypass valve in “bypass” position by pushing the stem inward.
  • Fully open the house main water pipe shutoff valve. Observe a steady flow from both faucets opened above.

To valve inlet · Ground Clamp · From valve outlet

Page 10 of the GE GNSH45E user manual — SALT LEVEL
Page 10 · click to enlarge
Page 10

CONNECT TO ELECTRICAL POWER

To gain access to the transformer/power cord assembly, remove the salt hole cover from the softener. Unclip the tabs on the rear of the top cover and rotate the cover upward to remove. DO NOT PULL OR DISCONNECT WIRING.

  • The softener works on 24 volt-60Hz electric power. The included transformer changes standard 120-volt AC house power to 24 volts. Plug the transformer into a 120-volt outlet only. Be sure the outlet is always live so it can not be switched off by mistake.
  • Replace the top cover.
  • Replace the salt hole cover.

PROGRAMMING THE CONTROL

PROGRAMMING THE CONTROL

SET PRESENT TIME OF DAY

1. Press the MODE button until arrow points to PRESENT TIME.

SALT LEVEL

PM

2. Press UP or DOWN button to set. The UP button advances the time; the DOWN button moves the time in reverse.

CONTROL SETTINGS REQUIRED upon installation and after an extended power outage.

. If the present time is between noon and midnight,

be sure PM shows in the display. If the present time is between midnight and noon, be sure AM shows in the display.

NOTES:

  • WHEN THE TRANSFORMER IS PLUGGED INTO THE ELECTRICAL OUTLET, 12:00 PM (flashing), and an arrow is displayed next to PRESENT TIME on the faceplate decal. The blue indicator light will also flash. Program the control as instructed below.
3. When the present time is correct, press MODE to accept.

If - - - is flashing, use the UP button to set the correct F or P code as follows: P39 for GXSH39E or P45 for GNSH45E. If you pass by the correct code number, use the DOWN button. Then press the MODE button to accept the correct model.

SET WATER HARDNESS NUMBER

1. Press the MODE button until arrow points to HARDNESS .

SALT LEVEL

  • A “beep” sounds while pressing buttons for control programming. One beep signals a change in the control display. Repeated beeps mean the control will not accept a change from the button you have pressed, and you should select another button.
2. Press UP or DOWN button to set your water hardness number in the display. DOWN decreases the hardness value. UP increases the hardness value.
  • To program the control, you will use the UP , DOWN and MODE buttons.
  • Use the MODE button to scroll arrow to desired control function.
Page 11 of the GE GNSH45E user manual — SALT LEVEL
Page 11 · click to enlarge
Page 11

SET WATER HARDNESS NUMBER (CONT.)

SET SALT LEVEL

3. When the display shows your water hardness (in grains per gallon), press MODE to accept.
1. Press the MODE button until arrow points to SALT LEVEL.

SALT LEVEL

2. Determine level of salt in brine tank using yellow indicator on side of brine well, inside brine tank (see illustration on page 5).

You can get the grains per gallon (gpg) hardness of your water supply from a water analysis laboratory. If you are on a municipal supply, call your local water department. Or call Legend Technical Services, an independent laboratory, to request a water hardness test kit at 1.800.949.8220, Option 4. If your report shows hardness in parts per million (ppm) or milligrams per liter (mg/l), simply divide by 17.1 to get the equivalent number of grains per gallon.

3. Press UP or DOWN button to set the SALT LEVEL to correspond to level on yellow indicator in brine tank.

SALT LEVEL

4. Press the MODE button to accept. The display shows the present time of day and DAYS TO EMPTY. RECHARGE TONIGHT may appear if unit is new.

SALT LEVEL

DAYS TO EMPTY PM

SET RECHARGE (STARTING) TIME

E

1. Press the MODE button until arrow points to RECHARGE TIME.

AM

RECHARGE TONIGHT

SALT LEVEL

DAYS TO EMPTY

The words DAYS TO EMPTY and a number are shown in the lower half of the display. This information is shown in the normal run display. This is to inform the user of the number of days before the salt level in the brine tank reaches Level 0. There will be salt left in the salt tank, but it may not be sufficient to fully recharge the system. Salt should be added at this time to avoid hard water. The value is updated daily and whenever the SALT LEVEL value is changed.

SALT LEVEL

DAYS TO EMPTY PM

If no change is needed, go to step 3. To change the recharge starting time, follow step 2.

2. Press UP or DOWN button to set the desired recharge start time. Be sure to observe the AM or PM as you did when setting the time of day.
3. Press the MODE button to accept.

It takes a couple of months for the water softener to learn your water usage pattern. Once it does this, it will accurately determine actual salt usage pattern. During this first period, check salt level when blue indicator light flashes. If the salt level in the tank is at Level 1 or above, allow system to run. Be sure to reset your salt level indicator each time you add salt to the system.

Page 12 of the GE GNSH45E user manual — SALT LEVEL
Page 12 · click to enlarge
Page 12

OPTIONAL CONTROL SETTINGS

FEATURE: OTHER DATA DISPLAYS

The controller display has several options and features.

These models have an option to have the run display indicate different information. The information displayed on the top half of the display can be changed to one of the following:

LOW SALT ALARM

SALT LEVEL

The LOW SALT ALARM, when enabled, will sound the beeper when the DAYS TO EMPTY value is 15 days or less. To change this setting, press and hold the MODE button for 3 seconds. ON (factory default) or OFF will flash in the display. Press the UP

  • CAPACITY REMAINING – This is the percentage of water softening capacity remaining. Immediately after a regeneration, 100% shows. As water is used, the percentage will decrease until the next regeneration. During regenerations, the percentage increments upward.

or DOWN buttons to toggle this feature ON or OFF. Press the MODE button to accept, and the display will move to SALT EFFICIENCY.

When PRESENT TIME is displayed, press the DOWN button; % REM will appear in the display. The value shown is between 0 and 100 percent. This value is based on current operating capacity. Pressing the UP button will return the screen to the previous display.

SALT LEVEL

%REM ADG GPM

DAYS TO EMPTY

E

SALT EFFICIENCY

SALT LEVEL

RECHARGE TONIGHT

When the SALT EFFICIENCY feature is ON, the unit will operate at a salt efficiency of 4000 grains of hardness removed per pound of salt. This mode of operation is the most efficient setting for salt usage, because the system will tend to recharge more often, with less salt usage. Turning the feature OFF will tend to lengthen the time between recharge cycles, which will provide the most efficient usage of water, but may use more salt. The degree of difference between these two cycles is highly dependent on the water usage and hardness at a particular installation.

E

  • AVERAGE DAILY GALLONS – The figure displayed is the average gallons of water used by the household each day over the past seven-day period.

Press the DOWN button again to display the Average Daily Gallons. ADG will appear in the display. This value is updated every night at midnight. Pressing the UP button will return the screen to the previous display.

%REM ADG GPM

SALT LEVEL

DAYS TO EMPTY

E

RECHARGE TONIGHT

  • FLOW RATE, GPM – When using soft water, this display shows the flow rate passing through the softener (in gallons per minute). Zero shows if water is not passing through the softener.

To change the setting, press the UP or DOWN buttons to toggle the feature ON or OFF. Press the MODE button to accept. The display will move to SYSTEM/ELECTRONIC DIAGNOSTICS.

Press the DOWN button again to display the flow rate. GPM will appear in the display. This value is updated every 1⁄ 2 second. Pressing the UP button will return the screen to the previous display. Pressing the DOWN button will return the screen to the PRESENT TIME display.

SALT LEVEL

%REM ADG GPM

DAYS TO EMPTY

SYSTEM/ELECTRONIC DIAGNOSTICS

E

SALT LEVEL

RECHARGE TONIGHT

This display contains system diagnostics information to assist in troubleshooting problems with the system. See page 18 for details. Press the MODE button to return to the normal run display.

Page 13 of the GE GNSH45E user manual — BLUE INDICATOR LIGHT
Page 13 · click to enlarge
Page 13

SIGNALS

LOST TIME SIGNAL

If time is lost on the display due to power interruption, the blue indicator light will flash 4 times every second, until the present time of day is entered.

LOW SALT SIGNAL

When the DAYS TO EMPTY drops to 15, the blue indicator light and DAYS TO EMPTY in the display will flash every second and the alarm will beep every 30 seconds (from 8:00 AM to 8:00 PM), to notify the user that the unit is running low on salt. As soon as any button is pressed, the alarm will stop beeping. The blue indicator light and DAYS TO EMPTY will continue to flash. Once salt is added to the brine tank and the SALT LEVEL is reset, the DAYS TO EMPTY will be reset.

ERROR SIGNALS

If there is an error code detected, the blue indicator light will flash 4 times every second, the display will flash Err and the alarm will beep every 30 seconds (from 8:00 AM to 8:00 PM) to signal that the softener requires service. The alarm can be turned off by pressing any button, but the blue indicator light and display will continue to flash.

SALT LEVEL

See page 18 for information to assist in troubleshooting error codes. Once the problem is corrected, disconnect the transformer from the wall outlet momentarily, and plug it back in. The normal display will appear. The motor may run for several minutes, as the unit resets. If the problem is not corrected, the error code will reappear in 6 minutes.

BLUE INDICATOR LIGHT

Steady blue light indicates that the unit is working correctly. The light flashes when the unit needs attention from the user.

  • Light flashes and DAYS TO EMPTY flashes—check salt level and add salt as required.
  • Light flashes and Err is in the display—electrical problem with system—see page 18.
  • Light will also flash when power to the unit has been interrupted. Check the PRESENT TIME setting.
Page 14 of the GE GNSH45E user manual — INLET
Page 14 · click to enlarge
Page 14

SANITIZING PROCEDURES

To complete the installation, do the following sanitizing procedures.

water softener, and out the drain. This process takes approximately 2 hours.

Care is taken at the factory to keep your water softener clean and sanitary. Materials used to make the softener will not infect or contaminate your water supply and will not cause bacteria to form or grow. However, during shipping, storage, installation and operation, bacteria could get into the softener. For this reason, sanitizing as follows is suggested when installing.

4. If, after sanitization, water from the house faucet tastes salty or has a slight color, this is a preservative from the resin tank. Turn on the cold soft water faucets and drain for a few minutes or until clear.

NOTE: When the sanitizing recharge is over, all remaining bleach is flushed from the conditioner and your house COLD water supply is fully soft immediately. However, your water heater is filled with hard water and as hot water is used, it will refill with soft water. When all the hard water is replaced in the water heater, hot only and mixed hot and cold water will be fully soft. If you want totally soft water immediately, after the above recharge, drain the water heater until the water runs cold.

1. Be sure to complete all installation steps, including programming the control.
2. Pour about 3/4 oz. (1 1 ⁄ 2 tablespoons) of common 5.25% unscented household bleach (Clorox, Linco, Bo Peep, White Sail, Eagle, etc.) into the brinewell . Refer to illustration on page 5.
3. IMPORTANT: Press and hold for 3 seconds the faceplate RECHARGE button to start an immediate recharge. RECHARGE begins to flash in the display. The bleach will be drawn through the

SPECIFICATIONS/DIMENSIONS

GXSH39E GNSH45E

Rated Capacity* 11,700 grains with 13,300 grains with 2.3 lbs of salt 2.6 lbs of salt 30,800 grains with 35,500 grains with 8.5 lbs of salt 9.8 lbs of salt 39,000 grains with 45,100 grains with 14.7 lbs of salt 17.0 lbs of salt

33⁄8″

INLET

OUT

INLET– OUTLET

Rated Efficiency** 5,100 grains/lb. 5,120 grains/lb. @ 2.3 lbs. of salt @ 2.6 lbs. of salt

Amount of High Capacity Resin (lbs/cu. ft) 56.2/1.08 65.0/1.25

Resin Tank Nominal Size (in., dia. x height) 9 x 40 10 x 40

471⁄2″ 411⁄4″ 16″

Service Flow Rate (gpm) 10 9.5

Water Supply Maximum Hardness (gpg) 110 160

Water Supply Maximum Clear Water Iron (ppm)*** 5 12

Water Pressure Limits (min.–max. psi)**** 20–125 20–125

Pressure Drop at Rated Service Flow (psig) 14 10

Water Temperature Limits (min.–max. °F) 40–120 40–120

Maximum Flow Rate to Drain (gpm) 2.3 2.3

These systems conform to NSF/ANSI 44 for the specific capacity claims as verified and substantiated by test data. * Testing was performed using pellet grade sodium chloride as the regenerant salt. ** Efficiency rating is valid only at the lowest stated salt dosage. These softeners were efficiency rated according to NSF/ANSI 44. *** Extent of iron removal may vary with conditions. The capacity to reduce clear water iron is substantiated by WQA test data. State of Wisconsin requires additional treatment if water supply contains greater than 5 ppm clear water iron. Use of Diamond Crystal® Red•Out® or Super Iron Out® will improve iron removal. Refer to Cleaning Iron Out of the Water Softening System section. **** Canada working pressure limits: 1.4–7.0 kg/cm2.

19″

Page 15 of the GE GNSH45E user manual — Automatic Hard Water Bypass During Recharge
Page 15 · click to enlarge
Page 15

About the water softener system. ge.com

Service

When the water softening system is providing soft water, it is called “Service.” During service, hard water flows from the house main water pipe into the water softening system. Inside the water softening system resin tank is a bed made up of thousands of tiny, plastic resin beads. As hard water passes through the bed, each bead attracts and holds the hard minerals. This is called ion-exchanging. It is much like a magnet attracting and holding metals. Water without hard minerals (soft water) flows from the water softening system and to the house pipes.

After a period of time, the resin beads become coated with hard minerals and they have to be cleaned. This cleaning is called recharge. Recharge is started at 2:00 AM (factory setting) by the water softening system control, and consists of five stages or cycles. These are FILL, BRINING, BRINE RINSE, BACKWASH and FAST RINSE.

Automatic Hard Water Bypass During Recharge

For emergency needs, hard water is available to the home during the recharge cycles.

However, you should avoid using HOT water because the water heater will fill with the hard water.

Fill Salt dissolved in water is called brine. Brine is needed to clean the hard minerals from resin beads. To make the brine, water flows into the salt storage area during the fill stage.

Backwash During backwash, water travels up through the resin tank at a fast flow rate, flushing accumulated iron, dirt and sediments from the resin bed and to the drain.

Brining During brining, brine travels from the salt storage area into the resin tank. Brine is the cleaning agent needed to remove hard minerals from the resin beads. The hard minerals and brine are discharged to the drain.

Fast Rinse Backwash is followed by a fast flow of water down through the resin tank. The fast flow flushes brine from the bottom of the tank, and packs the resin bed.

After fast rinse, the water softening system returns to soft water service.

The nozzle and venturi create a suction to move the brine, maintaining a very slow rate to get the best resin cleaning with the least salt.

Brine Rinse After a pre-measured amount of brine is used, the brine valve closes. Water continues to flow in the same path as during brining, except for the discontinued brine flow. Hard minerals and brine flush from the resin tank to the drain.

Page 16 of the GE GNSH45E user manual — Cleaning the Nozzle and Venturi Assembly
Page 16 · click to enlarge
Page 16

About the water softener system.

Breaking a Salt Bridge

Sometimes, a hard crust or salt bridge forms in the salt storage area. It is usually caused by high humidity or the wrong kind of salt. When the salt bridges, an empty space forms between the water and salt. Then salt will not dissolve in the water to make brine.

GE GNSH45E — Breaking a Salt Bridge diagram (page 16)
Fig. 2 · Breaking a Salt Bridge

If the brine tank is full of salt, it is hard to tell if you have a salt bridge. Salt is loose on top, but the bridge is under it. The following is the best way to check for a salt bridge.

Salt should be loose all the way to the bottom of the tank. Take a broom handle or like tool, and carefully push it down into the salt, working it up and down. If the tool strikes a hard object (be sure it’s not the bottom or sides of the tank), it’s most likely a salt bridge. Carefully break the bridge with the tool. Do not pound on the walls of the tank.

If the wrong kind of salt made the bridge, take it out. Then fill the tank with nugget or pellet salt only. In humid areas, it is best to fill with less salt, more often to prevent a salt bridge from forming.

Cleaning the Nozzle and Venturi Assembly

A clean nozzle and venturi is needed for the water softening system to work properly. This small unit makes the suction to move brine from the salt storage area to the resin tank during recharge. If it becomes plugged with sand, dirt, etc., the water softening system will not work and you will get hard water.

GE GNSH45E — Cleaning the Nozzle and Venturi Assembly diagram (page 16)
Fig. 3 · Cleaning the Nozzle and Venturi Assembly

To get to the nozzle and venturi, remove the water softening system top cover. Be sure the water softening system is in service cycle (no water pressure at nozzle and venturi). Then, while holding the nozzle and venturi housing with one hand, remove the cap. Lift out the screen support and screen, then the nozzle and venturi. Wash and rinse the parts in warm water until clean. If needed, use a small brush to remove iron or dirt. Also check and clean the gasket.

Carefully replace all parts in the correct order. Lightly lubricate the o-ring seal with clean silicone grease or petroleum jelly and place in position. Install and tighten the cap, by hand only. Do not overtighten the cap.

Show 4 more labels / short text on this page
Salt · Broom handle · Salt bridge · Water level
Page 17 of the GE GNSH45E user manual — Feature/Service: Automatic Electronic Diagnostics
Page 17 · click to enlarge
Page 17

ge.com

Normal Operation, Control Displays

During normal operation, the present time of day and AM or PM and DAYS TO EMPTY show in the control display area. When the demand computer determines a recharge is needed, RECHARGE TONIGHT begins to flash in the display along with the present time. RECHARGE TONIGHT flashes until the next recharge start time, then changes to RECHARGE, which flashes until the recharge is over.

Feature: Optional Recharge Controls

Sometimes, a manually started recharge may be desired or needed. Two examples:

RECHARGE TONIGHT Touch (do not hold) the RECHARGE button. RECHARGE TONIGHT flashes in the control display area. A recharge will occur at the next preset recharge start time. If you decide to cancel this recharge, touch the same button once more.

I You have used more water than usual (house

guests, extra washing, etc.) and you may run out of soft water before the next recharge.

I The system ran out of salt.

Use one of the following features to start a recharge immediately, or at the next preset recharge start time.

RECHARGE Press and hold the RECHARGE button until RECHARGE starts to flash in the control display area. The water softening system begins an immediate recharge and, when over in about two hours, you will have a new supply of soft water. Once started, you cannot cancel this recharge.

Feature: Memory

If electrical power to the water softening system is interrupted, the control display is blank, and the blue indicator light is off, but the control keeps correct time for about 6 hours. When power is restored, you have to reset the present time only if the display and blue indicator light are flashing. All other settings are maintained and never require resetting unless a change is desired.

If the time is flashing after a long power outage, the water softening system continues to work as it should to provide you with soft water. However, recharge may occur at the wrong time of day until you reset the control to the correct time of day.

Feature/Service: Automatic Electronic Diagnostics

The control computer has a self-diagnostic function for the electrical system (except input power and water meter). The computer monitors the electronic components and circuits for correct operation. If a malfunction occurs, an error code appears in the control display.

The chart on Error Codes shows the error codes that could appear and possible reasons for each code. See Manually Initiated Electronics Diagnostics to further isolate the defect.

Page 18 of the GE GNSH45E user manual — POWER OK
Page 18 · click to enlarge
Page 18

About the water softener system.

Service: Electronic Demand Time Features and Service

ERROR CODE DISPLAYED ERR 01 ERR 02 ERR 03 ERR 04 ERR 05

  • POSSIBLE DEFECT
  • Motor
  • Position
  • Motor
  • Position
  • Control inoperative switch inoperative switch or or wiring wiring harness harness
  • Wiring
  • Control
  • Control
  • Control harness or connection to switch
  • Position switch
  • Control

To remove an error code: 1. Unplug transformer.

2. Correct defect. 3. Plug transformer in. 4. Wait for at least 6 minutes. The error code will return if the reason for the error code was not corrected.

Service: Timer/Softener, Service Checkout Procedure

If you are not getting soft water, and an error code is not displayed, use the procedures below to find the problem. First make the following visual checks.

2. Is there sufficient salt in the storage tank?
3. Is the softener bypass valve directing water for soft water service?
4. Is the valve drain hose open to the drain, not more than 8 ′ above the softener, and unobstructed? If hose is above 8 ′ , see page 8, step 5.

VISUAL CHECKS:

1. Is there electrical power to the outlet the water softening system transformer is plugged into?

If you do not find a problem with the visual checks, continue below.

NO SOFT

CONTROL SHOWS WRONG TIME AND DAY, AND/OR IS FLASHING.

Electrical power was off. Reset the correct time of day.

Investigate reason for power loss.

WATER

Check electrical power to control (outlet, transformer, power cable, all connections).

REPAIR AS NEEDED

Do manual diagnostics to verify proper function.

NOPOWER

CONTROL DISPLAY BLANK.

POWER OK

CONTROL DEFECTIVE

CONTROL DISPLAY SHOWS CORRECT TIME AND DAY AND IS STEADY.

Do manual diagnostics.

Page 19 of the GE GNSH45E user manual — SALT LEVEL
Page 19 · click to enlarge
Page 19

ge.com

Service: Manually Initiated Electronics Diagnostics

1. To enter diagnostics, press and hold the MODE button for 3 seconds until the Low Salt Alarm screen shows.

– If there is no reading in the display, with faucet open,

SALT LEVEL

check the sensor. Pull the sensor from the valve outlet port, and pass a small magnet in front of the sensor. Counter should index in the display. If counter does not index, check to make sure harness is connected to board properly. If there is a reading in the display, there may be a problem associated with the turbine. Turn off water supply, close the bypass valve and disconnect bypass valve from body. Check turbine for binding or restriction due to debris. If this does not correct the problem, the Timer, Sensor or Turbine may require replacement.

2. Press the MODE button 2 times to advance through Low Salt Alarm and Salt Efficiency options. See Programming the Control for details on these two options.

SALT LEVEL

3. OPERATION OF DIAGNOSTICS

4. Historical data about the softener is available.
  • Press and hold the UP button to display the number of days this control has had electrical power applied.

SALT LEVEL

  • Press and hold the DOWN button to display the number of recharges initiated by this control since the model code number was entered.
5. Press the MODE button to return to normal operation and display.
  • Valve Position – Press the RECHARGE button to initiate a recharge cycle. Press again to manually index valve to next position. See Service: Manually Advance Recharge Check for details.

Service: Set Model (F or P) Code

0. Service 1 – Fill 2 – Brine 3 – Backwash 4 – Fast Rinse
1. To change or check model code, first press and hold the MODE button for 3 seconds until the Low Salt Alarm screen shows.
2. Press and hold the MODE button again for 3 seconds. A display with at the top will appear.

SALT LEVEL

  • Motor Operation – Two dashes will circulate around when motor should be running.
3. Press the UP or DOWN buttons to select the correct model code.
  • Position Switch Operation –

– Closed – valve rotating to next position

– Open – valve in position, service, fill, brine, etc.

4. Press the MODE button one time to return to normal operation and display. If the model code was changed:
  • Water Meter – Indicates whether water is flowing through valve.
  • the display will go blank momentarily, then display the model code entered.
  • the display will then return to the set present time display, and the blue indicator light will flash. The control will have to be reprogrammed. See Programming the Control .

Turbine support and shaft

– 000 indicates no water is flowing through the valve

– Open nearby soft water faucet

– 000 to 141 (continual) shows water is flowing. Display

repeats for each gallon of water passing through the meter. Control will beep at every gallon.

Show 9 more labels / short text on this page
Position switch Motor · Valve position · Water meter · P39–GXSH39E or P45–GNSH45E · Motor · Position switch · Sensor housing · Turbine · Valve outlet
Page 20 of the GE GNSH45E user manual — Service: Manually Advance Recharge Check
Page 20 · click to enlarge
Page 20

About the water softener system.

Service: Manually Advance Recharge Check

1. Press the RECHARGE button and hold in for three seconds. RECHARGE begins to flash as the water softening system enters the fill cycle of recharge. Remove the brinewell cover and, using a flashlight, observe fill water entering the brine tank. If water does not enter the tank, look for an obstructed nozzle, venturi, fill flow plug or brine tubing. See Care and Cleaning of the Water Softener System section.
3. Again, press the RECHARGE button to move the water softening system into backwash. Look for a fast flow of water from the drain hose. A slow flow indicates a plugged top distributor, backwash flow plug or drain hose.
4. Press the RECHARGE button to move the water softening system into fast rinse. Again look for a fast drain flow. Allow the water softening system to rinse for a few minutes to flush out any brine that may remain in the resin tank from the brining cycle test.
2. After observing fill, press the RECHARGE button to move the water softening system into brining. A slow flow of water to the drain will begin. Verify brine draw from the brine tank by shining a flashlight into the brinewell and observing a noticeable drop in the liquid level over an extended period of time.
5. To return the water softening system to service, press the RECHARGE button.

If the water softening system does not draw brine, check:

I nozzle and/or venturi dirty or defective. I defective nozzle and venturi seal. I nozzle and venturi not seated properly

on gasket. I other inner valve defect (rotor seal, rotor and

disc, wave washer, etc.). I restricted drain (check drain fitting and

hose).

Page 21 of the GE GNSH45E user manual — Cleaning Iron Out of the Water Softening System
Page 21 · click to enlarge
Page 21

Care and cleaning of the water softening system. ge.com

Checking the Salt Storage Level and Refilling

Brine (salt dissolved in water) is needed for each and every recharge. The water for making brine is metered into the salt storage area by the water softening system valve and control. However, you must keep the tank supplied with salt.

Use clean water softening salts only, at least 99.5% pure. NUGGET, PELLET or coarse SOLAR salts are recommended. Do not use rock, block, granulated or ice cream making salts. They contain dirt and sediments, or mush and cake, and will create maintenance problems.

When to refill with salt: If the blue indicator light and DAYS TO EMPTY are flashing, there is less than 15 days supply of salt. Refill with salt. In humid areas it is best to refill with less salt and more often, to avoid the forming of a salt bridge (see page 16). After adding salt, remember to reset the SALT LEVEL in the control (see page 11). Never allow the salt level to drop below zero on the yellow indicator before you refill it. Without enough salt, you will soon have hard water.

CAUTION: Water softening salt with iron removing additives: Some salts may have an additive to help the water softening system handle iron in the water supply. Although this additive may help to keep the water softening system resin clean, it may also release corrosive fumes that weaken and shorten the life of some water softening system parts. GE recommends using only Diamond Crystal® Red•Out® brand salt.

Cleaning Iron Out of the Water Softening System

Your water softening system takes hardness minerals (calcium and magnesium) out of the water. Also, it can control some (see the Specification Guidelines section) “clear water” iron. With clear water iron, water from a faucet is clear when first put into a glass. After 15 to 30 minutes, the water begins to cloud or turn rust colored. A water softening system will not remove any iron that makes the water cloudy or rusty as it comes from the faucet (called red water iron). To take red water iron out of water, or over the maximum of clear water iron, an iron filter or other equipment is needed.

IMPORTANT: It is important to mix the resin bed cleaner with water (following the manufacturer’s instructions), pour it into the brinewell tube (see page 5) and recharge the softener immediately. Do not pour the resin bed cleaner in with the salt, as it will not be as effective in cleaning the resin, and can cause damage to the softener if it is left in the brine tank for an extended period due to the corrosive gases that are formed.

GE recommends using only Diamond Crystal® Red•Out® brand salts with Iron Fighter® additive to help keep the resin bed clean of clear iron. If your water supply has clear water iron, periodic resin bed cleaning is needed. GE recommends using Super Iron Out® brand resin bed cleaner to thoroughly clean your resin bed if your iron content is high. Clean the bed at least every six months, or more often if iron appears in the soft water between cleanings.

Page 22 of the GE GNSH45E user manual — Problem Possible Causes What To Do
Page 22 · click to enlarge
Page 22

Before you call for service…

Troubleshooting Tips Save time and money! Review the chart on this page first and you may not need to call for service.

  • NO SOFT WATER – Most Common Problems: Check the following before calling for service:
  • Not enough salt—should be at least 1/3 full.
  • Bypass valve in “Bypass” position—knob should be in the “OUT” (service)position.
  • Hardness setting too low. Check hardness setting and adjust. Verify hardness of supply water—from local water company, water test or call the GEAnswer Center.
  • Salt Bridge—salt solidifies above water level so that brine water is not in contact with salt. See the Breaking a Salt Bridge section.

Problem Possible Causes What To Do

No soft water Faucet or fixture where sample was • To conserve salt, the installer may have isolated some fixtures taken not plumbed to soft water. (outside faucets, toilets, etc.) from soft water. From the outlet NOTE: Be sure sample is from a faucet of the water softening system, trace the water flow path, that does not mix soft and hard water. in house plumbing. If soft water is not directed to a faucet For example, a single lever kitchen faucet, or fixture where wanted, consult a plumber. if the cold side is plumbed to hard water.

No salt in the brine tank or • Check for a salt bridge or, if the tank is empty, refill with salt bridged recommended salt. Press (for 3 seconds) the RECHARGE button to start an immediate recharge and restore soft water supply.

Transformer unplugged at wall outlet or • Check for a loss of electrical power to the water softening power cable to softener not connected. system, due to any of these conditions and correct as needed. Fuse blown or circuit breaker popped With the power supply restored, observe the faceplate time on circuit to electrical outlet. display and read Programming the Control section. Electrical outlet on a circuit that can NOTE: The electrical outlet for the softener should be continuously be switched off live so it cannot be accidentally switched off.

Manual bypass valve in bypass position • Be sure the bypass valve stem is positioned properly, with the

knob in the OUTposition. Observe instructions on the decal at the end of the stem.

Valve drain hose pinched, plugged, • Any restriction in this drain hose may prevent proper elevated too high or otherwise operation of the nozzle and venturi and reduce or prevent restricted brine draw during recharge.

Nozzle and venturi dirty, incorrectly • Refer to Cleaning the Nozzle and Venturi Assembly instructions. assembled or damaged With water pressure to the water softening system off, take the nozzle assembly apart. Inspect, clean and replace as needed. Any foreign particle(s), scratches, nicks, etc., in the passages can prevent operation. Be sure holes in the gasket are centered over holes in the housing.

Page 23 of the GE GNSH45E user manual — Problem Possible Causes What To Do
Page 23 · click to enlarge
Page 23

ge.com

Problem Possible Causes What To Do

Water hard sometimes Using hot water while the water • Avoid using hot water during water softening system softening system is regenerating recharge because the water heater will refill with hard water. See Automatic Hard Water Bypass During Recharge section, page 15.

Control HARDNESS number setting • Press the MODE button until arrow points to HARDNESS. too low Be sure the number shown is the same as the actual grains per gallon hardness of your water supply. See the Programming the Control section if a change in the setting is needed.

Grains of hardness in your water • Water hardness can change over time, especially in well water. supply have increased To check, have the water tested by a water analysis laboratory or call your local water department. Adjust the HARDNESS number setting as needed.

Water feels slippery Absence of hardness minerals • This is normal. Hardness in water gives it the abrasive feel after installation of you may have been accustomed to. The slippery feel is the water softening system clean feel of soft water.

Water softening system Water softening system is a • Does not use much salt to regenerate—very efficient. not using any salt “demand” unit

Possible salt bridge • See the About the Water Softener System section, page 16.

Possible plugged nozzle and venturi • See the About the Water Softener System section, page 16.

Water is blue color Acidic water in copper plumbing • Have the water tested at once. after water softening system was installed

  • Water softening system Meter turbine stuck
  • See the Service: Manually Initiated Electronics Diagnostics not regenerating section for troubleshooting procedures, page 19.
  • Call for service.
  • Sensor wire not plugged into
  • See the Service: Manually Initiated Electronics Diagnostics the control section for troubleshooting procedures, page 19.
  • Call for service.

No power to unit • Check the circuit breaker or fuses.

Mechanical defect • Call for service.

Cloudiness on glassware Combination of soft water and • This is called etching and is permanent. To prevent this (automatic dishwashers) too much detergent from happening, use less detergent if you have soft water. Wash glassware in the shortest cycle that will get them clean.

Excessive/high level Valve drain hose pinched, • Any restriction in this drain hose may prevent proper of water in brine tank plugged, elevated too high operation of the nozzle and venturi and reduce or prevent or otherwise restricted brine draw during recharge.

Nozzle and venturi dirty, incorrectly • See the Cleaning the Nozzle and Venturi Assembly section, assembled or damaged page 16. With water pressure to the water softening system off, take the nozzle assembly apart. Inspect, clean and replace as needed. Any foreign particle(s), scratches, nicks, etc., in the passages can prevent operation. Be sure holes in the gasket are centered over holes in the housing.

Page 24 of the GE GNSH45E user manual — Blue light flashing
Page 24 · click to enlarge
Page 24

Troubleshooting Tips Before you call for service…

Problem Possible Causes What To Do

  • Salty tasting or Unit not sanitized
  • Complete the Sanitization Procedures on page 14. brown/yellow colored
  • At completion of recharge cycle(approx. 2 hrs), run water water after installation from faucets to purge the salty water.

Low water pressure Check pressure. • Drain height 8′ or less, pressure should be minimum of 20 psi.

  • Drain height above 8 ′ , pressure should be minimum of 50 psi.

Restricted drain hose • Clean and reconnect hose.

  • Check for kinks in drain line.

Brown/yellow Unit was idle for a period of time • Complete the Sanitization Procedures on page 14. colored water

Resin beads showing Cracked distributor • Call for service. up in drinking water and sink

Sounds you might hear Running water from the unit • This is normal. into a drain during recharge

Water has air bubbles Air in system after installation • Will go away after it runs for a while. and is cloudy

  • Error Code on control Wiring may have worked loose
  • See page 18 for details. in the control
  • Unplug transformer.
  • Remove control cover, release clips on side.
  • Check for loose/incorrect wiring connections to electronic board or switch. Reconnect as required.
  • Reassemble control cover.
  • Plug in Transformer.
  • Wait six minutes for Error Code to reappear.
  • If Error Code reappears, call for service.

Blue light flashing

When power applied Control needs to be programmed • See the Programming the Control section, page 10. to the system (a power outage may have occurred)

  • If “DAYS TO EMPTY” Low salt level, less than 15 days
  • Fill with salt. is flashing
  • Reset salt level.

If “Err” in display Electrical problem with system • See page 18 for details.

  • See procedure above, Error code on control.
Page 25 of the GE GNSH45E user manual — Troubleshooting Tips
Page 25 · click to enlarge
Page 25
Page 26 of the GE GNSH45E user manual — Troubleshooting Tips
Page 26 · click to enlarge
Page 26
Page 27 of the GE GNSH45E user manual — Parts list. ge.com
Page 27 · click to enlarge
Page 27

Parts list. ge.com

GE GNSH45E — Parts list. ge.com diagram (page 27)
Fig. 4 · Parts list. ge.com
Page 28 of the GE GNSH45E user manual — Parts list/catalog
Page 28 · click to enlarge
Page 28

Parts list.

GE GNSH45E — Parts list/catalog diagram (page 28)
Fig. 5 · Parts list/catalog
Page 29 of the GE GNSH45E user manual — GENERAL ELECTRIC PARTS CATALOG
Page 29 · click to enlarge
Page 29

Parts catalog. ge.com

GENERAL ELECTRIC PARTS CATALOG

G G X N S S H H 3 4 9 5 E E

REF. NO. GE PART NO. PART DESCRIPTION (03) (03)

0002 WS31X10018 BACK COVER, ELECTRONICS 1 1 0003 WS35X10001 O-RING SEAL KIT 1 1 0004 WS34X10016 DECAL, FACEPLATE 1 1 0005 WS07X10004 HOSE, DRAIN, 20 FT. 1 1 0007 WS14X10002 DISTRIBUTOR, TOP 1 1 0008 WS14X10001 DISTRIBUTOR, BOTTOM 1 1 0009 WS01X10009 RESIN, 1-CU. FT. 1 1 0010 WS32X10011 RESIN TANK 9X40 1 0010 WS32X10018 RESIN TANK 10X40 1 0011 WS31X10022 COVER, TOP W/ LENS 1 1 0012 WS31X10023 FACEPLATE 1 1 0013 WS21X10016 CONTROL 1 1 0016 WS26X10013 TRANSFORMER WITH POWER CORD 1 1 0017 WS31X10021 COVER, SALT HOLE, WITH LABELS 1 1 0018 WS33X10001 VAPOR BARRIER 1 1 0019 WS33X10007 RIM 1 1 0020 WS31X10024 COVER, BRINEWELL W/ DECAL 1 1 0021 WS02X10009 NUT 1 1 0022 WS32X10017 BRINEWELL W/ DECAL 1 1 0023 WS02X10027 SCREW 1 1 0024 WS32X10016 TANK, BRINE, ROUND 1 1 0025 WS18X10003 CLAMP, HOSE 2 2 0026 WS22X10016 ADAPTER, HOSE 1 1 0027 WS22X10017 GROMMET 1 1 0028 WS35X10035 GROUND CLAMP KIT 1 1 0029 WS15X10035 BRINE VALVE ASM. 1 1 0030 WS35X10036 FLOAT, STEM & GUIDE 1 1 0031 WS03X10006 CLIP 1 1 0032 WS15X10006 VALVE BODY, BRINE 1 1 0033 WS03X10007 CLIP 1 1 0034 WS03X10008 SCREEN 1 1 0035 WS07X10002 TUBING ASM. 1 1 0036 WS07X10015 BRINE TUBE ASM. 1 1 0038 WS02X10029 SPACER 1 1 0039 WS02X10030 FACEPLATE SUPPORT 1 1 0055 WS28X10003 RETAINER CLAMP 2 2 0056 WS28X10007 CLAMP 2 2 0101 WS02X10023 SCREW 2 2 0103 WS21X10003 SWITCH 1 1 0105 WS02X10024 SCREW 8 8 0106 WS31X10013 COVER, VALVE 1 1 0107 WS03X10034 WAVE SPRING 1 1 0108 WS26X10010 ROTOR & DISC ASM. 1 1 0109 WS19X10004 CAP, VENTURI 1 1 0110 WS03X10011 SEAL, O-RING 5 5

Page 30 of the GE GNSH45E user manual — GENERAL ELECTRIC PARTS CATALOG
Page 30 · click to enlarge
Page 30

Parts catalog.

GENERAL ELECTRIC PARTS CATALOG

G G X N S S H H 3 4 9 5 E E

REF. NO. GE PART NO. PART DESCRIPTION (03) (03)

0111 WS19X10005 SUPPORT SCREEN 1 1 0112 WS03X10013 SCREEN 1 1 0113 WS22X10034 FLOW PLUG, .10 GPM 1 0113 WS22X10036 FLOW PLUG, .15 GPM 1 0114 WS08X10006 GASKET & ASPIRATOR 1 0114 WS08X10007 GASKET & ASPIRATOR 1 0115 WS03X10015 CONE SCREEN 1 1 0116 WS22X10021 PLUG, FILL FLOW .30 GPM 1 1 0117 WS03X10017 FERRULE NUT 1 1 0118 WS15X10034 NOZZLE/VENTURI BODY 1 1 0119 WS03X10018 RETAINER 1 1 0120 WS03X10019 SEAL, O-RING 1/4″ X 3/8″ 2 2 0121 WS15X10025 BODY, VALVE 1 1 0122 WS03X10020 SPRING 1 1 0123 WS22X10029 PLUG, DRAIN SEAL 1 1 0124 WS15X10027 NOZZLE/VENTURI ASM. 1 0124 WS15X10036 NOZZLE/VENTURI ASM. 1 0125 WS03X10043 WAVE SPRING BEARING 1 1 0130 WS35X10020 SEAL KIT, 1″ 1 1 0132 WS22X10058 ADAPTER, DRAIN HOSE 1 1 0135 WS03X10033 CLIP 1 1 0136 WS26X10008 CAM & GEAR 1 1 0137 WS26X10009 BEARING 1 1 0138 WS26X10007 PLATE, MOTOR 1″ 1 1 0139 WS02X10028 SCREW, #6-20 X 3/8″ 3 3 0140 WS26X10011 MOTOR ASM. 1 1 0141 WS02X10016 SCREW, #6-20 X 7/8″ 2 2 0143 WS60X10011 ADAPTER–NPT THREAD–1″ VALVE 2 2 0145 WS60X10008 CLIP 4 4 0146 WS28X10018 HARNESS WIRE, SENSOR ASSY., 1″ 1 1 0147 WS19X10008 TURBINE SUPPORT 1 1 0148 WS19X10009 TURBINE 1 1 0150 WS03X10024 SEAL, O-RING 1 1 0151 WS15X10026 BYPASS ASM. 1 1 0998 WS35X10049 INSTALLATION KIT 1 1 0999 49-50180-1 OWNER’S MANUAL 1 1

Page 31 of the GE GNSH45E user manual — Warrantor: General Electric Company. Louisville, KY 40225
Page 31 · click to enlarge
Page 31

GE Water Softening System Warranty. (For Customers in the United States)

All warranty service provided by our SmartWater™Authorized Servicer Network. To schedule service, call 800.952.5039 (U.S.) or 866.777.7627 (Canada). Please have serial number and model number available when calling for service.

Staple your receipt here. Proof of the original purchase date is needed to obtain service

under the warranty.

For The Period Of: We Will Replace:

One Year Any part of the Water Softening System which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor and related original purchase service to replace the defective part.

Three Years The electronic monitor, if it fails due to a defect in materials or workmanship. During this From the date of the three-year limited warranty, you will be responsible for any labor or related service costs. original purchase

Ten Years A replacement brine tank or cabinet, if either fails due to a defect in materials or workmanship. From the date of the During this ten-year limited warranty, you will be responsible for any labor or related service costs. original purchase

What Is Not Covered:

I Service trips to your home to teach you how to use

I Replacement of house fuses or resetting of circuit breakers.

the product.

I Damage to the product caused by accident, fire, floods or

I Improper installation, delivery or maintenance.

acts of God.

I Failure of the product if it is abused, misused, altered, used

I Incidental or consequential damage caused by possible

commercially or used for other than the intended purpose.

defects with this appliance, its installation or repair.

I Use of this product where water is microbiologically unsafe

I Product not accessible to provide required service.

or of unknown quality, without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor: General Electric Company. Louisville, KY 40225

Page 32 of the GE GNSH45E user manual — What Is Not Covered:
Page 32 · click to enlarge
Page 32

GE Water Softening System Warranty. (For Customers in Canada )

All warranty service provided by our Factory Service Centers or an authorized technician. For service, call toll free 1.866.777.7627. Please have serial number and model number available when calling for service.

For The Period Of: We Will Replace:

One Year Any part of the Water Softening System which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor and related original purchase service to replace the defective part.

Three Years The electronic monitor, if it fails due to a defect in materials or workmanship. During this From the date of the three-year limited warranty, you will be responsible for any labor or related service costs. original purchase

Ten Years A replacement brine tank or cabinet, if either fails due to a defect in materials or workmanship. From the date of the During this ten-year limited warranty, you will be responsible for any labor or related service costs. original purchase

What Is Not Covered:

I Service trips to your home to teach you how to use

I Replacement of house fuses or resetting of circuit breakers.

the product.

I Damage to the product caused by accident, fire, floods or

I Improper installation, delivery or maintenance.

acts of God.

I Failure of the product if it is abused, misused, altered, used

I Incidental or consequential damage caused by possible

commercially or used for other than the intended purpose.

defects with this appliance, its installation or repair.

I Use of this product where water is microbiologically unsafe

I Product not accessible to provide required service.

or of unknown quality, without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within Canada. In-home warranty service will be provided in areas where it is available and deemed reasonable by Mabe to provide.

WARRANTOR IS NOT RESPONSIBLE FOR CONSEQUENTIAL DAMAGES.

Warrantor: MABE CANADA INC.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the GE GNSH45E

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE GNSH45E

Be the first to ask — other owners or our team will answer.

Original document

GE GNSH45E manual PDF

64 pages·1.6 MB·Water System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…