GE Consumer & Industrial Lighting
The use of these products requires awareness of the following safety issues:
ConstantColor™ CMH™
DATASHEET

ConstantColor CMH™ lamps combine HPS technology (providing stability, efficiency & uniformity) and Metal Halide Technology (providing bright white quality light) to produce highly efficient light sources with good colour rendering and consistent colour performance through life. This is achieved by using the ceramic arc tube material from the Lucalox™ lamp, which minimises the chemical changes inside the lamp through life. When combined with the halide doses used in Arcstream™ Metal Halide lamps then the quality and stability of the dose maintains the colour consistency. Hence the name ConstantColor CMH™.
Always follow the supplied lamp operation and handling instructions.
Single ended Ceramic Metal Halide lamps are designed to provide symmetrical beam distribution using the axial con- figuration of the discharge arc. A variety of beam angles are possible and adjustable beam control can be built into the luminaire. This compact lamp shape enables luminaire size to be minimised and the bi-pin lamp base enables easy changing with front access.
Metal halide lamps, traditionally made with quartz arc tubes, are prone to colour shift through life and lamp-to-lamp colour variation. Some of the dose, e.g. sodium, (an important component of metal halide lamps), can migrate through quartz to cause colour shift and loss of light through life. The ceramic arc tube resists this material loss, can be manufactured to tighter tolerances and withstands a higher temperature to provide a more constant colour.
GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this brochure are intended as a general guide, and we may change specifications time to time in the interest of product development, without prior notification or public an- nouncement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability arising from the reliance on such data to the extent permitted by law. CMH Single Ended G8.5 Product Information for OEMs 17th July, 2007
and General Electric are both registered trademarks of the General Electric Company

Specification summary*
20W 3000K 35W 3000K Plus 35W 4200K 70W 3000K Plus 70W 4200K Photometric Characteristics
Description Wattage Colour Product Code
Product code 39858 43237 26348 43274 26349
100 hrs Lumens lm 1650 3400 3150 6200 6000
CMH20/T/UVC/U/830/G8.5 Plus 20 3000K 39858
Typical Lumen change with burning position – vertical to horizontal
CMH35/T/UVC/U/830/G8.5 Plus 35 3000K 43273
CMH70/TC/UVC/U/830/G8.5 Plus 70 3000K 43274
Typical voltage change with burning position – vertical to horizontal
Correlated Colour Temperature K 3000 3000 4200 3000 4200
Chromaticity X 0.435 0.435 0.475 0.435 0.475
20W 3000K 35W 3000K Plus 35W 4200K 70W 3000K Plus 70W 4200K General Units
Chromaticity Y 0.400 0.400 0.370 0.400 0.370
Product code 39858 43273 26348 43274 26349
Colour Rendering Index Ra 80+ 84+ 88+ 80+ 90+
Luminous efficacy lm/W 85 86 80 86 83
Nominal Wattage W 20 35 35 70 70
Base G8.5
Bulb type T4.5
Bulb diameter mm 14.5
Bulb material UVC Quartz
Time to start ( at 25 °C ) sec. < 2 < 2 < 2 < 2 < 2
Arc Gap mm 3.35 4.65 4.3 7.4 5.5
Time to start - Cold box test at -30 °C sec. < 2 < 2 < 2 < 2 < 2
Base G8.5
Hot restart time min. < 3 < 3 15 15 15
Warm-up time (for 90% lumens) min. 1.2 1.2 3 3 3
* Typical values (actual values are ballast and ignitor dependent)
Through life Performance*
Lumen maintenance at 40% rated life (mean lumens) % 68 68 85 71 77
Notes: 1) Lamp voltage in the luminaire should not increase by more than 5V when compared to lamp voltage in free air. 2) Ballast protection required, according to IEC61167. 3) 35W & 70W data is based on operation from a conventional magnetic ballast. Improved performance can be achieved using an electronic ballast. 4) 35W 4200K CMH lamp is based on operation from an electronic ballast. Lamps can run on conventional ballast with a small reduction in performance. 5) 20W designed for operation only from an electronic ballast.
Average rated life h 12000 15000 12000 15000 15000
* Life data measured in Vertical Base up position. Performance can be greatly increased in horizontal position.
Electrical Characteristics *
Maximum allowed bulb temperature (horizontal orientation, thermocouple attached above burner)
Lamp power W 20 39 39 72 72
Lamp voltage V 90
Maximum pinch temperature (vertical base up orientation) °C 300
Lamp current A 0.226 0.50 0.50 0.98 0.98
Max. Ignition Voltage kV *** 5.0
* The specification provides typical performance data for 35W & 70W operating from a 50Hz mains sinewave supply at nominal power. Actual values depend on ballast, supply voltage and application 20W to be used only with an electronic ballast – see later for additional notes on electronic ballast requirements. ** Temperatures above which lamp performance or reliability is impaired. Additionally, voltage rise when operated in luminaire should not exceed 5V *** Photometric characteristics refer to lamp performance after 100hrs burning.
Min. Ignition Voltage kV *** 3.5
Extinction voltage (% of rated input voltage) % *** 90 (Max.) 90 (Max.) 90 (Max.) 90 (Max.)
* The specification provides typical performance data for 35W & 70W operating from a 50Hz mains sinewave supply at nominal power. Actual values depend on ballast, supply voltage and application 20W to be used only with an electronic ballast *** See additional notes on electronic ballast requirements for 20W


Life survival graphs are shown for statistically representative batches of lamps operated under controlled nominal conditions with a 7 hours per start switching cycle. Declared lamp life is the median value, i.e. when 50% of lamps from a large sample batch would have failed. Lamp life in service is affected by a number of parameters, including supply voltage variation, switching cycle, operating position, ballast impedance tolerance, luminaire design and mechanical vibration.
The information provided is intended to be a practical guide for comparison with other lamp types. Determination of lamp replacement schedules will depend upon relative costs of spot or group replacement and acceptable reduction in lighting levels.




Special power distribution
Lumen maintenance graphs show light output performance through life for statistically representative batches of lamps operated under controlled nominal conditions with a 7 hours per start switching cycle. A common characteristic for all metal halide lamps is a reduction in light output and a slight increase in power consumption through life. Consequently there is an economic life at which lamp efficacy falls to a level when lamps should be replaced to restore design illumination levels. Where a quantity of lamps are installed within an area, consideration should given to a group lamp replacement programme to maintain uniform illumination levels. Curves represent operating conditions for a 7 hours per start switching cycle, but less frequent switching will improve lumen maintenance.
Spectral Power Distribution [3000K]
Spectral Power Distribution [4200K]


Lumen Maintenance 20W G8.5 3000K
380 430 480 530 580 630 680 730
380 430 480 530 580 630 680 730
2 4 6 8 10 12 0
Burning time (thousand hours)
Lumen Maintenance 35W G8.5 3000K
Lumen Maintenance 35W G8.5 4200K
Vertical plane polar intensity curve
Imax=170.13 cd at 100º Vertical plane polar intensity curve
Imax=170.13 cd at 100º
165˚ 150˚ 165˚ 150˚ 135˚
195˚ 180˚ 210˚ 165˚ 150˚ 135˚
2 4 6 8 10 12 0
2 4 6 8 10 12 14 16 0
Burning time (thousand hours)
Burning time (thousand hours)
Lumen Maintenance 70W G8.5 3000K
Lumen Maintenance 70W G8.5 4200K
45˚ 30˚ 15˚ 15˚ 30˚
45˚ 30˚ 15˚ 305˚ 330˚
C180 C270 C0 C90
2 4 6 8 10 12 14 16 0
2 4 6 8 10 12 14 16 0
Burning time (thousand hours)
Burning time (thousand hours)

Lamp end of life conditions
During the warm-up period immediately after starting, lamp temperature increases rapidly evaporating mercury and metal halide dose in the arc-tube. Lamp electrical characteristics and light output stabilise in less than 4 minutes. During this period light output increases from zero to full output and colour approaches the final visual effect as each metallic element becomes vaporised.
The principal end-of-life failure mechanism for CMH™ lamps is arc tube leakage into the outer jacket. High operating temperature inside the arc-tube causes metal halide dose material to gradually corrode through the ceramic arc tube wall, eventually resulting at normal end-of-life in leakage of the filling gas and dose. Arc-tube leakage into the outer jacket can be observed by a sudden and significant lumen drop and a perceptible color change (usually towards green). The above situation is often accompanied by the so-called rectification phenomena. This occurs where a discharge is established between two mount-frame parts of different material and/or mass, causing asymmetry in the electrical characteristic of the resulting discharge current. Rectification can lead to overheating of the ballast, therefore conventional magnetic ballasts must conform to requirements of the IEC61167 lamp standard by incorporating protection to maintain safety and prevent damage. It is good practice when lamps are operated continuously 24 hours per day, 7 days per week to introduce switching once every 24 hours. Lamps with one electrode failing often will not restart and can therefore be easilly detected and replaced.
Percentage of final value
Lamp voltage Lamp current Light output
1 0 2 3 4
Time from switch-on (minutes)
Supply line voltage to conventional magnetic ballast control gear should be as close to the rated nominal value as possible. Lamps will start and operate at 10% below rated supply voltage but this should not be considered as a normal operating condition. In order to maximise lamp survival, lumen maintenance and colour uniformity, supply voltage and rated ballast voltage should be within ±3%. Supply variations of ±5% are permissible for short periods only. Where large supply voltage variation is likely to occur, use of electronic control gear, which is designed to function correctly for a voltage range typically 200-250V, should be considered.
CMH Lamp performance as a function of supply voltage on a 220V Reference Ballast
Volts Current Watts Lumens CCT LPW
All metal halide lamps experience a reduction in light output and slight increase in power consumption through life. Consequently there is an economic life when the efficacy of lamps fall to a level at which is advisable to replace lamps and restore illumination levels. Where a number of lamps are used within the same area it may be well worth considering a group lamp replacement programme to ensure uniform output from all the lamps.
209 198 220 231 242 253
A condition can exist at end-of-life whereby lamp voltage rises to a value exceeding the voltage supplied by the control gear. In such a case the lamp extinguishes and on cooling restarts when the required ignition voltage falls to the actual pulse voltage provided by the ignitor. During subsequent warm-up the lamp voltage will again increase, causing extinction. This condition is known as end-of-life cycling. Normally cycling is an indication that lamp end-of-life has been reached, but it can also occur when lamps are operated above their recommended temperature. Lamp voltage at 100 hours life should not increase by more than 5V when operating in the luminaire, when compared to the same lamp operating in free-air. A good luminaire design will limit lamp voltage rise to 3V. It is good practice to replace lamps that have reached end-of-life as soon as possible after failure, to minimise electrical and thermal stress on ignitor internal components. The use of a ‘timed’ or ‘cut-out’ ignitor is not a specific requirement for ConstantColor CMH™ lamps, but is worth considering as a good optional safety feature which also prolongs the life of ignitor internal components, lamp holder contact surfaces and fixture wiring. The operating period of a timed/cut-out ignitor must be adequate to allow lamps to cool and restart. A period of 10 to 15 minutes continuous or intermittent operation is recommended before the ignitor automatically switches off. Timed/cut-out ignitors specifically offered for High-Pressure Sodium lamps, where the period of operation is less than 5 minutes, are not suitable for ConstantColor CMH™ lamps.
CMH Lamp performance as a function of supply voltage on an electronic ballast
Volts Current Watts Lumens CCT LPW
209 198 220 231 242 253
In certain cases, dimming may be acceptable, subject to further testing. Contact your GE representative for more information. Large changes in lamp power alter the thermal characteristics of the lamp resulting in lamp colour shift and possible reduction in lamp through life survival.
When ConstantColor CMH™ lamps are operated from a conventional magnetic ballast there will be 50Hz line frequency light output flicker typically of 1.5%, in common with all other discharge lamps. Noticeably lower flicker levels occur when lamps are operated horizontally.
Flicker levels of 1.5% do not normally cause concern to the end user, but use of electronic control gear should be considered where visual comfort and performance is critical. Suitable electronic ballasts for ConstantColor CMH™ typically provide square wave operation in the range 70-200Hz, eliminating perceptible flicker.

Information on luminaire design
The wall of the bulb, which is produced with specially developed ‘UV Control’ material, absorbs potentially harmful high energy UV radiation emitted by the ceramic arc-tube. The use of UV control material together with an optically neutral front glass cover allows the lamp to significantly reduce the risk of discolouration or fading of products. When illuminating light-sensitive materials or at high light levels, additional UV filtration is recommended. Luminaires should not be used if the front glass is broken or missing. It is recommended that a safety interlock switch is incorporated into the luminaire to prevent operation when the luminaire is opened. Although PET determines limits of human exposure to lamp UV, the risk of fading of mechanise due to UV can be quantified by a Damage Factor and a Risk of Fading. The risk of fading is simply the numerical product of the illuminance, exposure time and damage factor due to the light source. Finally the selection of luminaire materials should take into consideration the UV emission. Current UV reduction types on the market are optimised for UV safety of human eye and skin exposure. However, luminaire materials may have different wavelength dependent response functions. Designers must take account of emission in each of the UV-A, UV-B and UV-C spectral ranges as well as material temperatures when designing luminaires. Typical values for UV-A, UV-B and UV-C range radiation can be found in the table below.
ConstantColor CMH™ operate from the same type of ballast as conventional quartz technology metal halide lamps of the same nominal power. IEC 61167 MH lamp standard and IEC62035 HID lamp safety standard specify use of ballast thermal protection or equivalent protection device in the circuit. This safety device will protect the ballast and fixture from overheating damage at lamp end-of-life should rectification occur due to electrode imbalance or arc-tube failure. The IEC61167 requirement applies to both ceramic and quartz arc tube metal halide lamps of the UV-A, UV-B and UV-C spectral ranges as well as material temperatures when designing luminaires. ConstantColorTM CMH G8.5 lamps are compatible with a list of approved ballasts; contact your GE representative for more information.
At the design stage for fixtures incorporating the control gear, careful consideration should be given to the physical layout of the lamp and ballast. The relative positions and distance between lamp and ballast can adversely affect lamp performance and drastically reduce lamp life survival. Conventional magnetic ballasts can produce a stray magnetic field and if the lamp is placed within this field, “bowing” of the arc in the discharge tube can occur. Since ceramic is a very rigid material severe arc bowing can cause high thermal stress leading to cracking or rupture of the arc-tube resulting in failure of the lamp early in life. Such bowing of the arc can also affect the quartz arc-tube in conventional metal halide lamps, but cracking or rupture failure is less likely since quartz softens at the resulting higher wall temperature causing the arc-tube to become swollen. Excessive swelling of a quartz arc-tube can however also result in cracking or rupture failure. In fixtures where the ballast is necessarily placed close to the lamp, use of magnetic shielding is essential. Another solution is to use an electronic ballast, which eliminates the need for an ignitor, simplifies wiring, reduces the risk of stray magnetic field and eliminates light output flicker.
20W 3000K 35w 3000K 35w 4200K 70w 3000K 70w 4200K
UV-PET Performance µW / (cm²) / 500LUX
UV C 220-280nm 0.036 0.0367 0.020 0.014 0.011
UV B 280-315nm 0.049 0.0467 0.040 0.006 0.009
UV A 315-400nm 10.170 10.360 113.870 6.980 9.800
UVB/UVA 0.005 0.005 0.003 0.001 0.0099
Eeff 0.052 0.034 0.015 0.014
PET (h)±10% 16 15 26 54 64
Risk Group IESNA RP-27.3-96 Exempt
Circuit diagram electronic ballast
CMH 20W is designed only for operation from electronic gear*. This provides many advantages:
LH = Lamp holder E = Electronic Gear
LH
Containment requirement
ConstantColor CMH™ lamps operate above atmospheric pressure, therefore a very small risk exists that the lamp may shatter when the end-of-life is reached. Although this failure mode is unlikely, containment of shattered particles is required as prescribed by IEC 61167. ConstantColor CMH™ lamps should only be operated in a suitable enclosed luminaire with front cover glass capable of containing the fragments of a lamp, should it shatter.
Lamp type

Electronic Ballasts
Mains Voltage V 220...240
Mains Current A 0.19 0.10 0.18 0.33 0.69
A range of GE electronic ballasts have been introduced to complement the 20, 35, 70 and 150W ConstantColor™ Ceramic Metal Halide lamps Power controlled electronic ballasts suitable for operation of Ceramic Metal Halide lamps are available from various gear manufacturers.
Mains Frequency Hz 50 50...60
Power Factor > 0.55 > 0.95 > 0.95 > 0.95 > 0.95
Allowed Mains Voltage Range V 198...264
Ignition Voltage* kV < 3.5 < 2.5 < 2.5 < 2.5 < 2.5
Lamp Operating Frequency Hz 133 150

Max Cable Capacitance pF 1000 1000 3000 3000 3000
Max Lamp Distance** m 2 10 25 25 25
Ambient Temperature Range °C -20...+50
Maximum Case Temperature °C 80 75 75 75 80
Thermal Cut-off on PCB °C 110
* If a hot lamp or no lamp is detected the ballast will attempt to start the lamp after one minute, if not successful further attempts are made up to a maximum of 4 times in 5 minute cycles, then if not successful the ballast will shut-down. The ballast is reset automatically by a supply interruption. ** Typical value if cable capacitance is below the specifi ed limit
Features
BLS/E/20W/CMH BLS/E/35W/CMH
BLS/E/70W/CMH BLS/E/20W/CMH/R BLS/E/35W/CMH/R BLS/E/70W/CMH/R
BLS/E/150W/CMH BLS/E/150W/CMH/R






Watts Volts Description Mounting Weight Pack Qty Product Code
20 220-240 BLS/E/20W/CMHSMP Integral 110 g 12 42387
20 220-240 BLS/E/20W/CMH Integral 190 g 12 13032
20 220-240 BLS/E/20W/CMH/R Remote 230 g 12 13034
35 220-240 BLS/E/35W/CMH Integral 215 g 12 13035
35 220-240 BLS/E/35W/CMH/R Remote 230 g 12 13036
70 220-240 BLS/E/70W/CMH Integral 300 g 12 13040
Circuitry
70 220-240 BLS/E/70W/CMH/R Remote 310 g 12 13047
150 220-240 BLS/E/150W/CMH Integral 430 g 12 13050
– RFI suppression EN 55015 – Harmonics EN 61000-3-2 – Immunity EN 61547 – Safety EN 60926/EN 60928/EN 61347 – Performance EN 60927/EN 60929
150 220-240 BLS/E/150W/CMH/R Remote 445 g 12 13053
L N L BLS/E/20W/CMH BLS/E/35W/CMH
N
BLS/E/20W/CMH/R BLS/E/35W/CMH/R BLS/E/70W/CMH BLS/E/70W/CMH/R BLS/E/150W/CMH BLS/E/150W/CMH/R
System Power W 23.5 43 78 159
System lm/W 72 79 79 88
Lumens* lm 1700 3400 6200 14000
Lamp Power W 20 39 72 146
Lamp Efficacy lm/W 85 87 86 96
Lamp Voltage Range V 70…125
* Data shown relates to 3000K products. Please see lamp data sheets for performance of equivalent 4200K rated products.



In many installations Ceramic Metal Halide lamps are operated from a conventional magnetic ballast in conjunction with a superimposed ignitor. These ignitors generate starting pulses independently from the ballast and should be placed close to the lamp, preferably within the luminaire. Wiring between ignitor and lamp should have a maximum capacitance to earth of 100pF (length equivalent to less than 1 Metre) - contact ignitor manufacturer for details of specific ignitor types. A typical circuit diagram is shown:
Impulser type ignitors use the ballast winding as a pulse transformer and can only be used with a matched ballast. Always check with the ballast and ignitor supplier that components are compatible. Longer cable lengths between ballast & ignitor and the lamp are possible due to the lower pulse frequency generated, giving greater flexibility for remote control gear applications. Ignitor pulse characteristics at the lamp must however comply with specified minimum values for ConstantColor CMH™ lamps under all conditions.
Suitable Ignitors
Suitable high-energy (superimposed) ignitors recommended by control gear manufacturers are listed below. Check 0with suppliers for their current range of ignitors. Lamp re-starting under warm lamp conditions can take up to 15 minutes. Suitable ignitors to achieve a warm restart of less than 15 minutes include the following, however the list may not be fully inclusive:
The use of a ‘timed’ or ‘cut-out’ ignitor is not a specific requirement for ConstantColor CMH™ lamps but it is a good optional safety feature worth considering to prolong ignitor component life. The timed on-period must be adequate to allow lamps to cool and restart as described below. A period of 10-15 minutes continuous or intermittent operation is recommended before the ignitor automatically switches off. Timed ignitors specifically offered for High-Pressure Sodium lamps where the period of operation is less than 5 minutes are not suitable for ConstantColor CMH™ lamps.
APF SP23
BAG Turgi NI 150 SE NI 150 SE-TM20 MZN 150 SE-C NI 400 LE/3.5 A NI 400 LE/3.5 A-TM20
ERC AZ A 1.8 AZ P 1.8 AZ P 1.8 T3 AZ P 1.8 T3 AZ P 3.0 T3
All ratings re-strike within 15 minutes following a short interruption in the supply. Actual re-strike time is determined by the ignitor type, pulse voltage and cooling rate of the lamp. Instant hot re-strike is only possible using a suitable very high voltage ignitor and a double ended lamp. GE Lighting should be consulted when considering use of an instant hot re-striking system.
Magnetek/May & Christe ZG 0.5 ZG 2.0 ZG 2.0D ZG 4.5D
Parry/Parmer PAV400 PCX400 PXE100
Thorn G53459 G53498 G53476 G53504.TB
Tridonic ZRM 1.8-ES/B ZRM 2.5-ES/B ZRM 4.5-ES/B ZRM 6-ES/B ZRM 2.5-ES/B
Vossloh-Schwabe Z 150 Z 150 K Z 150 K A10 Z 150 K A10 Z 250
The combined characteristics of ceramic arc-tube material and vacuum outer jacket result in ConstantColor CMH™ lamps cooling relatively slowly. It is possible with low energy ignitors to reach the required breakdown voltage but not create a full thermionic discharge. Under these conditions the lamp can remain very warm and be prevented from cooling to a temperature at which the arc can be re-established. To avoid this, turn off the power supply for approximately fifteen minutes or change to a suitable high energy ignitor from the list given in the superimposed ignitor section.
For a very short period immediately after switch-on, all discharge lamps can act as a partial rectifier and a conventional magnetic ballast may allow higher than the normal current to flow. At switch-on the short duration surge current drawn by the power factor correction capacitor can be high. In order to prevent nuisance fuse failure at initial switch-on, the fuse rating must take these transient conditions into account. A separate technical data sheet providing additional explanation and information for the fusing of High Intensity Discharge lighting circuits is available from GE Lighting.
Fusing of individual fixtures is recommended, in order to provide added protection for end-of-life conditions when lamp rectification can also occur.
35W Fuse Rating (A) 4
70W Fuse Rating (A) 4
150W Fuse Rating (A) 4 4 4 6 6 10
Helvar L-150 LSI-150T20 · Philips SU20S