Copyright © 2000 GE Power Management
INSTRUCTIONS
215 Anderson Avenue Markham, Ontario
ISO9002 Registered System · Manufactured under an · L6E 1B3 Canada



The ET-16 (incandescent and LEDs) and ET-17 (neon) indicating lamps consist of a common receptacle, plug in
type resistors and lamps, escutcheon, and color cap. They are available for mounting on switchboard panels up to
The ET-16 is available for either one brilliance or dim bright operation when incandescent lamps are used. ET-16
lamps are also available with Light Emitting Diodes (LEDs). The incandescent type can be easily upgraded to the
LED type. It only requires acquiring the appropriate color LED and lens cap and inserting into the lamp receptacle.
The ET-17 can be used when extra long life is a factor and brilliance is not. It also can be used when low current
80% of the rated bulb voltage to give it longer life. Changing voltages is easily accomplished by changing the series resistor (see listed tables for the proper resistor).
of the ratings. For LED types, long life LEDs (100,000 hours) are specified. Additional features are as
no cold filament inrush current. The LED lamps come in red, green, and amber colors. White is not an
Translucent caps: red, green, yellow, white; and four transparent caps: amber, red, green, blue, and clear.
For ET-16 LED types, only the transparent lens caps are recommended. This is because the transparent
lens allows more LED light to pass through than the translucent lens cap used on incandescent lamps.
ET-17: Because of the special properties of neon, only amber, transparent red, and clear lenses are
between the terminal and ground (panel) if a surge were to be induced on one of the potential leads.
If a bulb other than those listed above is required, the lamp will be furnished less the bulb.
option because a white light LED is not available. ET-17 uses GE Catalog Number B1A.
The available colors are as follows: red, green, amber, yellow smoke, clear and blue.
These lamps can be used whenever a panel mounted signal or indicating lamp is desired.
The color caps have a knurled OUTSIDE DIAMETER FOR EASY REMOVAL.
accomplished by incorporating a bayonet base on both components.
APPLICATION
FEATURES
Listed tables give some of the specials made available.
easy to change on the panel without disassembling.
the proper design, or designated series resistor.
and including ¼ inch thickness.
suitable.
screws.
is desired.


Thread the pal nut against the shoulder of the receptacle. Install the two-inch insulating washer on the front of the
receptacle against the pal nut. Insert the receptacle through the panel and thread the escutcheon nut against
panel. Install the color cap and hand tighten (do not force). Turn the escutcheon nut back up against the color cap,
then back off ½ to ¾ turn (¾ turn recommended) to give at least 1/64 inch clearance but not more than 1/32 inch
clearance between the color cap and escutcheon nut (for up to 3/16 inch panel). For the ¼-inch panel, the color
cap carton outline
cap will be flush with the escutcheon nut. Tighten the pal nut against panel to 10 to 12 inch-pounds of torque.

See Figure 1A and 1B for typical tell-tale and dim-bright connections.
0116B6709G3
RECOMMENDED PANEL ASSEMBLY
TABLE 1: ET-16 – INDICATING LAMP
(GE
No. Total Tap
50 1700 4400 1600 4200
CIRCUIT VOLTAGE Resistor 0165A9217
450 2550 6000 2450 5700
cap, and resistor) Part
1 2 3 4 5
0116B8108G2 0116B8108G3 0116B8108G4 0116B8108G5 0116B8108G6
28 V 56 V 140 V 280 V 130 V 260 V
volts MAX.
56 V 140 V 280 V 130 V 260 V
22 V 44 V 110 V 220 V 95 V 195 V
44 V 110 V 220 V 95 V 195 V
volts MIN.
24 V DC 48 V DC 125 V DC 250 V DC 120 V AC 240 V AC
48 V DC 125 V DC 250 V DC 120 V AC 240 V AC


Example: Using Table 3 to specify a complete ET-16 LED catalog number for a 24 V DC, Red LED Lamp, red
Cap Carton Outline
Receptacle with Resistor by Voltage LED Lamp by Voltage No.3 - Transparent

Digits Transp.

0116B6709G1
TABLE 3: ET-16 – FOR LEDs
B1A
125 DC 250 DC 110 220 140 280 116B6708G43 116B6708G44 125 DC 250 DC
No. Ohmic
200 K 560 K 750 K 1 M 1.2 M 1.6 M

Receptacle and Resistor by Voltage
LED Lamp Color by Voltage
Lens Cap by Color
1 2 3 4 5 6
(includes Lamp, color gap,
Cat. No.*
Specify color cap from Table 6 or 7
110-139 140-219 220-299 300-374 375-449 450-600



Receptacle DRG. No. Part No. Value GE Cat. No.
1 210 to 250 V AC/DC 1 56 KΩ NE51H **
TABLE 6: ET-17 SPECIAL 128B1654
1 REQD of GR. or PART NUMBER LISTED BELOW RESISTOR BULB Group No* Volts
INDICATING LAMP COMPLETE
1 REQD of GR. or PT NO. LISTED BELOW
** NE51H BULB Furnished by Customer
** 756 Bulb Furnished by Customer


Order by the complete Catalog Number and specify color cap. To order renewal parts for ET-16 LEDs or for
S4


1835L2R 1835L2G 1835L2A
1835L3R 1835L3G 1835L3A
1835L3R 1835L3G 1835L3A
ORDERING TABLE 8: COLOR CAP
TABLE 7: COLOR CAP
Incandescent ET16 conversion to LEDs, use the following table:
R53
R53
48 DC 2 200 Red
750 1900 2300 4800
7 5 13 6
70 AC 120 AC 130 AC 240 AC

![Page 8 of the GE ET-16 user manual — Figure 1 (0246A3685[1]): TYPICAL TELL-TALE AND DIM-BRIGHT CONNECTION](/cdn/reader/c6/c6861ad9de91e51bc08c608228f24139dd6cf2e86db1441ebacf4c8855730b77/images/page-8.webp?w=400)
![GE ET-16 — Figure 1 (0246A3685[1]): TYPICAL TELL-TALE AND DIM-BRIGHT CONNECTION diagram (page 8)](/cdn/reader/c6/c6861ad9de91e51bc08c608228f24139dd6cf2e86db1441ebacf4c8855730b77/images/fig-8-1.webp)


![Page 10 of the GE ET-16 user manual — Figure 3 (0165A7859[6]): OUTLINE AND PANEL DRILLING FOR TYPE ET-16 INDICATING LAMP](/cdn/reader/c6/c6861ad9de91e51bc08c608228f24139dd6cf2e86db1441ebacf4c8855730b77/images/page-10.webp?w=400)
![GE ET-16 — Figure 3 (0165A7859[6]): OUTLINE AND PANEL DRILLING FOR TYPE ET-16 INDICATING LAMP diagram (page 10)](/cdn/reader/c6/c6861ad9de91e51bc08c608228f24139dd6cf2e86db1441ebacf4c8855730b77/images/rimg-4.webp)
![Page 11 of the GE ET-16 user manual — Figure 3 (0165A7859[6]): OUTLINE AND PANEL DRILLING FOR TYPE ET-16 INDICATING LAMP](/cdn/reader/c6/c6861ad9de91e51bc08c608228f24139dd6cf2e86db1441ebacf4c8855730b77/images/page-11.webp?w=400)
![GE ET-16 — Figure 3 (0165A7859[6]): OUTLINE AND PANEL DRILLING FOR TYPE ET-16 INDICATING LAMP diagram (page 11)](/cdn/reader/c6/c6861ad9de91e51bc08c608228f24139dd6cf2e86db1441ebacf4c8855730b77/images/rimg-5.webp)

215 Anderson Avenue Markham, Ontario
L6E 1B3 Canada
Telephone (905) 294-6222
www.ge.com/indsys/pm
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.