DPSR405EAWW—GE Profile ™ Prodigy ™ Super 7.0 Cu. Ft. Capacity Dryer
Dryer Dimensions (in inches)
28-1/4 23-1/2
*24-1/2" from the edge of the side panel to the front. 25-1/2" from front to edge of endcaps.
Exhaust Options: 4-way via rear, right, left and bottom.
Circuit Requirements: An individual, properly-grounded branch circuit, protected by a 30-amp circuit breaker or a time-delay fuse, is required.
8-1/2
11-1/2
Installation Information: For complete information, see installation instructions packed with your dryer.
Side View Rear View
GE Profile Performance Series, ™
GE Profile™or GE appliance questions, call GE Answer Center® service, 800.626.2000.

DPSR405EAWW—GE Profile ™ Prodigy ™ Super 7.0 Cu. Ft. Capacity Dryer
Dryer Exhausting Information—Use Metal Duct Only For complete information, see installation instructions packed with your dryer.
Ducting Materials: For best performance, this dryer should be vented with 4” diameter all rigid metal exhaust duct. If “all rigid metal” duct cannot be used, then “flexible all metal” venting can be used, but it will reduce the maximum recommended duct length.
Exhaust Length Calculation: 1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12” above the ground or any other obstruction with the opening pointed Down.
Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4” opening dampered wall cap.
For more information on venting kits and accessories, please call 1-800-GE CARES.
GE Profile™or GE appliance questions, call GE Answer Center® service, 800.626.2000.
Minimum Clearances other than Alcove or Closet Installation: •Minimum clearances to combustible surfaces 0” both sides 3” rear
Listed by Underwriters Laboratories
Specification Revised 9/00

DPSR405EAWW—GE Profile ™ Prodigy ™ Super 7.0 Cu. Ft. Capacity Dryer

WRINKLE CARE EXTENDED COOL AIR TUMBLE SIGNAL ELECTRONIC TONE START
Super Capacity / 10 Cycle / Heavy Duty / Deluxe Quiet / Sensor Dry
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.