DPSE810EG GE Profile™ 7.0 Cu. Ft. Super Capacity Electric Dryer with Stainless Steel Drum
*24-1/2" from the edge of the side panel to the front. 25-1/2" from front to edge of endcaps.

Dimensions and Installation Information (in inches)
Circuit Requirements: An individual, properly-grounded branch circuit, protected by a 30-amp circuit breaker or a time-delay fuse, is required.
Installation Information: For complete information, see installation instructions packed with your dryer.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.
Listed by Underwriters Laboratories

DPSE810EG GE Profile™ 7.0 Cu. Ft. Super Capacity Electric Dryer with Stainless Steel Drum
For complete information, see installation instructions packed with your dryer.
Ducting Materials: For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If “all rigid metal” duct cannot be used, then “flexible all metal” venting can be used, but it will reduce the maximum recommended duct length.
Exhaust Length Calculation: 1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn.
Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside.
Minimum Clearances other than Alcove or Closet Installation: • Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Dryer Exhausting Information: Use metal duct only, vertical and horizontal ducting.

Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down.
Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4" opening dampered wall cap.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
Special Installation Requirements · Specification Revised 9/07

DPSE810EG GE Profile™ 7.0 Cu. Ft. Super Capacity Electric Dryer with Stainless Steel Drum

Specification Revised 9/07