EN
GE logo
Official user manual

GE DCD330E

20 pages·635 KB·Clothes Dryer·PDF·ENDEFRITNLJA
GE DCD330E
Table of Contents 18 sections TABLE OF CONTENTS · Safety Instructions · Safety Precautions · Care and Cleaning · … ShowHide
Page 1 of the GE DCD330E user manual — 131892900
Page 1 · click to enlarge
Page 1

Owner’s Manual & Installation Instructions

Dryers

Commercial

Models:

DCB330E DCB330G DCD330E DCD330G

GE Answer Center ® 800.626.2000

www.geappliances.com

Part No. 175D1807P295 Pub. No. 49-90028 10/99 JR

131892900

Page 3 of the GE DCD330E user manual — FOR GAS DRYERS: YOU MUST POST IN A PROMINENT LOCATION
Page 3 · click to enlarge
Page 3

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or death.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

FOR GAS DRYERS: YOU MUST POST IN A PROMINENT LOCATION

1. Instructions to follow if the user smells gas: Contact your local gas supplier for information to be displayed. 2. Instructions concerning flammable materials as follows:

FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

California Safe Drinking Water and Toxic Enforcement Act

This act requires the governor of California to publish a list of substances known to the state to cause cancer, birth defects or other reproductive harm and requires businesses to warn customers of potential exposure to such substances. Gas appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde and soot, caused primarily by the incomplete combustion of natural gas or LP fuels. Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances can be minimized further by properly venting the dryer to the outdoors.

PROPER INSTALLATION This dryer must be properly installed and located in accordance with the Installation Instructions before it is used.

I Properly ground dryer to conform with all

I Remove any accumulated time by manually

governing codes and ordinances. Follow details in the Installation Instructions section.

rotating timing cam in the coin box counterclockwise until switch shuts off. Apply a slight additional counterclockwise pressure to further seat drive. Make certain not to turn cam past switch shut-off position. Otherwise, one increment of time will be gained. Switches are off when the plastic switch actuating arm (inner) is down and all 3 switch buttons are depressed.

I Install or store where it will not be exposed to

temperatures below freezing or exposed to the weather.

I Connect to a properly rated, protected and sized

power supply circuit to avoid electrical overload.

I Remove all sharp packing items and dispose of all

Exhaust/Ducting:

shipping materials properly.

This dryer MUST be exhausted to the outside.

I In fulfilling the specific needs of different

Use only rigid metal or flexible metal 4″ diameter ductwork inside the dryer cabinet or for exhausting to the outside. USE OF PLASTIC OR OTHER COMBUSTIBLE DUCTWORK CAN CAUSE A FIRE. PUNCTURED DUCTWORK CAN CAUSE A FIRE IF IT COLLAPSES OR BECOMES OTHERWISE RESTRICTED IN USE OR DURING INSTALLATION.

commercial installations the purchaser of this dryer may wish to locate the coin box and controls in any of a number of locations. The responsibility for the proper performance of this work lies solely with the purchaser. It should be done by properly trained and qualified personnel, and in accordance with local code requirements.

Follow details in the Installation Instructions section.

I Any coin box or similar device added to the dryer,

either electrically or mechanically, should be properly grounded.

Page 4 of the GE DCD330E user manual — WHEN USING YOUR DRYER
Page 4 · click to enlarge
Page 4

WARNING!

YOUR LAUNDRY AREA

I Keep the area underneath and around your

I Close supervision is necessary if this appliance is

appliances free of combustible materials, such as lint, paper, rags, chemicals, gasoline and other flammable vapors and liquids.

used by or near children. Do not allow children to play on, with, or inside this or any other appliance.

I Keep all laundry aids (such as detergents,

I Keep the floor around your appliances clean and

bleaches, etc.) out of the reach of children, preferably in a locked cabinet. Observe all warnings on container labels to avoid injury.

dry to reduce the possibility of slipping.

I Keep area around the exhaust opening and

surrounding areas free from the accumulation of lint, dust and dirt.

I Never climb on or stand on the dryer top.

I Do not install or store this appliance where it will

I Do not obstruct the flow of ventilating air. Do not

be exposed to the weather.

stack or place laundry or throw rugs against the front or back of the dryer.

WHEN USING YOUR DRYER

I Never reach into the dryer while the drum is

I Do not dry articles containing rubber, plastic,

moving. Before loading, unloading or adding clothes, wait until the drum has completely stopped.

or similar materials such as padded bras, tennis shoes, galoshes, bath mats, rugs, bibs, baby pants, plastic bags, pillows, etc. that may melt or burn. Some rubber materials, when heated, can under certain circumstances produce fire by spontaneous combustion.

I Clean the lint filter before each load to prevent

lint accumulation inside the dryer or in the room. DO NOT OPERATE THE DRYER WITHOUT THE LINT FILTER IN PLACE.

I Do not store plastic, paper or clothing that may

burn or melt on top of the dryer during operation.

I Do not wash or dry articles that have been

cleaned in, washed in, soaked in, or spotted with combustible or explosive substances (such as wax, oil, paint, gasoline, degreasers, dry-cleaning solvents, kerosene, etc.) which may ignite or explode. Do not add these substances to the wash water. Do not use or place these substances around your washer or dryer during operation.

I Garments labeled Dry Away from Heat or Do

Not Tumble Dry (such as life jackets containing Kapok) must not be put in your dryer.

I Do not dry fiberglass articles in your dryer.

Skin irritation could result from the remaining particles that may be picked up by clothing during subsequent dryer uses.

I Any article on which you have used a cleaning

I To minimize the possibility of electric shock,

solvent or that contains flammable materials (such as cleaning cloths, mops, towels used in beauty salons, restaurants, or barber shops, etc.) must not be placed in or near the dryer until solvents or flammable materials have been removed. There are many highly flammable items used in homes such as acetone, denatured alcohol, gasoline, kerosene, some household cleaners, some spot removers, turpentines, waxes, wax removers and products containing petroleum distillates.

unplug this appliance from the power supply or disconnect the dryer at the distribution panel by removing the fuse or switching off the circuit breaker before attempting any maintenance or cleaning.

I Do not spray any type of aerosol into, on or near

dryer at any time.

I Do not place items exposed to cooking oils in

your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.

I The laundry process can reduce the flame

retardancy of fabrics. To avoid such a result, carefully follow the garment manufacturer’s care instructions.

Page 5 of the GE DCD330E user manual — Read and follow this Safety Information carefully. SAVE THESE INSTRUCTIONS
Page 5 · click to enlarge
Page 5

I Never attempt to operate this appliance if

I You may wish to soften your laundered fabrics or

it is damaged, malfunctioning, partially disassembled, or has missing or broken parts, including a damaged cord or plug.

reduce the static electricity in them by using a dryer-applied fabric softener or an anti-static conditioner. We recommend you use either a fabric softener in the wash cycle, according to the manufacturer’s instructions for those products, or try a dryer-added product for which the manufacturer gives written assurance on the package that their product can be safely used in your dryer. Service or performance problems caused by use of these products are the responsibility of the manufacturers of those products and are not covered under the warranty to this appliance.

I The interior of the machine and the exhaust duct

connection inside the dryer should be cleaned at least once a year by a qualified technician. See the Care and Cleaning section. Do not use any type of spray cleaner when cleaning dryer interior. Hazardous fumes or electrical shock could occur.

I If yours is a gas dryer, it is equipped with an

automatic electric ignition and does not have a pilot light. DO NOT ATTEMPT TO LIGHT WITH A MATCH. Burns may result from having your hand in the vicinity of the burner when the automatic ignition turns on.

WHEN NOT USING YOUR DRYER

I Grasp the plug firmly when disconnecting this

I Before discarding a dryer, or removing it from

appliance to avoid damage to the cord while pulling. Place the cord away from traffic areas so it will not be stepped on, tripped over or subjected to damage.

service, remove the dryer door to prevent children from hiding inside.

I Do not tamper with controls.

I Do not attempt to repair or replace any part of

this appliance or attempt any servicing unless specifically recommended in this Owner’s Manual or in published user-repair instructions that you understand and have the skills to carry out.

Read and follow this Safety Information carefully. SAVE THESE INSTRUCTIONS

Page 6 of the GE DCD330E user manual — Care and Cleaning of the Dryer
Page 6 · click to enlarge
Page 6

Care and cleaning.

Care and Cleaning of the Dryer

The Exterior: Wipe or dust any spills or washing compounds with a damp cloth. Dryer control panel and finishes may be damaged by some laundry pretreatment soil and stain remover products. Apply these products away from the dryer. The fabric may then be washed and dried normally. Damage to your dryer caused by these products is not covered by your warranty.

The Exhaust Duct: Inspect and clean the exhaust ducting at least once a year to prevent clogging. A partially clogged exhaust can lengthen the drying time. Follow these steps:

Turn off electrical supply by disconnecting the plug from the wall socket.

The Lint Filter: Clean the lint filter before each use. Run your fingers across the back of the filter to remove lint. Do not operate the dryer without the lint filter in place.

Disconnect the duct from the dryer.

Vacuum the duct with the hose attachment and reconnect the duct.

The Exhaust Hood: Check with a mirror that the inside flaps of the hood move freely when operating. Make sure that there is not wildlife (birds, insects, etc.) nesting inside the duct or hood.

Have a qualified technician vacuum the lint from the dryer once a year.

{ |

Show 4 more labels / short text on this page
· y z · · { |
Page 7 of the GE DCD330E user manual — Unpacking the Dryer
Page 7 · click to enlarge
Page 7

Preparing to install your dryer.

Read these instructions completely and carefully.

WARNING

I This dryer must be exhausted to the outdoors

(45.7 cm) off the ground and protected from vehicles by a barrier. See Location of Your Dryer section. I The electrical service to the dryer must conform

using only rigid metal or flexible metal 4″ diameter ductwork for inside the dryer cabinet or exhausting. I Never use plastic or other combustible ductwork.

with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70. I The gas service to the dryer must conform

See Exhausting section. I This appliance must be properly grounded

and installed as described in these Installation Instructions. I Do not install or store appliance in an area where

with local codes and ordinances or the latest edition of the National Fuel Gas Code ANSI Z223.1. The gas dryer is designed for use under ANSI Z 21.5.1. This dryer is not recommended for commercial applications such as restaurants or beauty salons, etc.

it will be exposed to water/weather. See Location of Your Dryer section. I The National Fuel Gas code restricts installations

of gas appliances in garages. They must be 18″

Tools and Materials Required for Dryer Installation

Electric Dryer I Channel-lock pliers (adjust leveling legs) I 1/2″ open-end wrench (lock leveling legs) I Carpenter’s level I Rigid or flexible metal 4″ (10.2 cm) duct I Duct tape I Vent hood I 1/4″ nut driver (remove terminal block access

Gas Dryer I Channel-lock pliers (adjust leveling legs) I 1/2″ open-end wrench (lock leveling legs) I Carpenter’s level I Rigid or flexible metal 4″ (10.2 cm) duct I Duct tape I Vent hood I Flexible stainless steel or plastic-coated brass

cover and install cord) I Flat or straight blade screwdriver (may be needed

connecting gas tube (if allowed by building code) I Connector for between dryer and flexible tube

(3/8″ pipe thread on dryer side, may be supplied with flexible tube) I Pipe thread sealer I Open-end wrenches for flexible tube and

for cord strain relief) I UL approved 30A, 240V, 3-wire, #10 AWG

minimum conductor power cord (For a mobile home installation, a UL approved 30A, 240V, 4-wire, #10 AWG minimum conductor power cord is required.) I UL approved cord strain relief (may be supplied

connector Door Reversal I Plastic knife I Phillips head or #1 square screw driver

Unpacking the Dryer

Using the four shipping carton corner posts (two on each side), carefully lay the dryer on its left side and remove foam shipping pad.

Return the dryer to an upright position.

Adjust the leveling legs to match the washer height. The dryer must be level and rest firmly on all four leveling legs. 3 2

with cord) · Foam shipping pad · Packing

Page 8 of the GE DCD330E user manual — Electrical Connection Information for Gas Dryers
Page 8 · click to enlarge
Page 8

Electrical requirements.

Read these instructions completely and carefully.

Electrical Connection Information for Electric Dryers

  • This dryer must be connected to an individual branch circuit, protected by the required timedelay fuses or circuit breakers. 208V or 240V installation 30 amps.
  • DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.
  • THIS APPLIANCE MUST BE PROPERLY GROUNDED.

This dryer must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, in accordance with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70.

  • Use copper conductors only.
  • If the electric supply does not meet the above specifications, call a licensed electrician.

control panel.

Electrical Connection Information for Gas Dryers

External Ground (if required)

An external ground wire, (not provided), which meets local codes, may be added by attaching it to the green ground screw on the rear of the dryer in the upper left hand corner, and to grounded metal cold water pipe or other established ground.

  • DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE.
  • DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD GROUNDING PRONG FROM THE POWER CORD.

This dryer must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, in accordance with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70.

Attach ground wire (obtain locally)

  • This dryer must be supplied with 120V, 60 Hz, and connected to an individual properly grounded brand circuit, protected by a 15 or 20 amp circuit breaker or time-delay fuse.
  • If the electric supply provided does not meet the above specifications, it is recommended that a licensed electrician install an approved outlet.

control panel.

Ensure proper ground exists before use

Electrical Requirements · Electrical Requirements

Page 9 of the GE DCD330E user manual — Additional Ducting Instructions
Page 9 · click to enlarge
Page 9

Exhausting the dryer.

Exhaust System Requirements

Use only 4″ (10.2 cm) diameter (minimum) rigid metal duct for best performance, or flexible metal duct. Use approved vent hood which has swing-out dampers that open when the dryer is in operation. When the dryer stops, the dampers automatically close to prevent drafts and the entrance of insects and rodents. To avoid restricting the outlet, maintain a minimum of 12″ (30.5 cm) clearance between the vent hood and the ground or any other obstruction.

The dryer exhaust system MUST BE EXHAUSTED TO THE OUTSIDE.

DO NOT allow combustible materials (for example: clothing, draperies/curtains, paper) to come in contact with exhaust system.

The dryer MUST NOT be exhausted into a gas vent, chimney, a wall, a ceiling, a common duct with a kitchen exhaust or any concealed space of a building which can accumulate lint, resulting in a fire hazard.

If all rigid metal duct cannot be used, then flexible all-metal venting can be used, but it will reduce the maximum recommended duct length. See Additional Installation Instructions following.

DO NOT exceed the length of duct pipe or number of elbows allowed in the Maximum Length charts. Lint can accumulate in the exhaust system, plugging the system and creating a fire hazard, as well as increasing drying times.

Correct

DO NOT screen the exhaust ends of the vent system, nor use any screws or rivets to assemble the exhaust system. Lint can become caught in the screen, on the screws or rivets, clogging the duct work and creating a fire hazard as well as increasing drying times. Use an approved vent hood to terminate the duct outdoors, and seal all joints with duct tape. All male duct pipe fittings MUST be installed downstream with the flow of air.

Incorrect

EXPLOSION HAZARD. Do not install the dryer where gasoline or other flammables are kept or stored. If the dryer is installed in a garage, it must be a minimum of 18″ (45.7 cm) above the floor. Failure to do so can result in death, explosion, fire or burns.

DO NOT use plastic flexible duct to exhaust the dryer. Excessive lint can build up inside exhaust system and create a fire hazard and restrict air flow. Restricted air flow will increase drying times. If your present system is made up of plastic duct or metal foil duct, replace it with rigid or flexible metal duct. Ensure the present duct is free of any lint prior to installing dryer duct.

Provide an access for inspection and cleaning of the exhaust system, especially at turns. Inspect and clean at least once per year.

Do not obstruct incoming or exhausted air.

Additional Ducting Instructions

If all rigid metal duct cannot be used, then flexible all-metal venting can be used, but it will reduce the maximum recommended duct length. In special installations when it is impossible to make a connection with the above recommendations, then UL-listed clothes dryer transition duct may be used as transition venting between the dryer and wall connection only. The use of this ducting will affect drying time.

The following directions must be followed.

  • Use the shortest length possible.
  • Stretch the duct to its maximum length.
  • Do not crush or collapse.
  • Never use transition duct inside the wall, flooring, ceiling or inside the dryer.
  • Avoid resting the duct on sharp objects.

If flexible transition duct is necessary, only UL-listed duct identified for use with clothes dryers is approved.

  • Venting must conform to local building codes.

Do Do Do · Don’t Don’t Don’t

Page 10 of the GE DCD330E user manual — Gas Supply Requirements
Page 10 · click to enlarge
Page 10
Safety InstructionsInstalling the dryer. Exhaust Ducting Length The exhaust system should be inspected and cleaned • DO NOT assemble the duct work with fasteners that at least once a year with normal usage. The more the extend into the duct. They will serve as collection dryer is used, the more often you should check the points for lint. exhaust system and vent hood for proper operation. • Ductwork which runs through an unheated area or If roof vents or louvered plenums are used, they must is near an air conditioning duct should be insulated be equivalent to a 4″ dampered wall cap in regard to to reduce condensation and lint build-up. resistance to airflow, prevention of back drafts and maintenance required to prevent clogging. MAXIMUM LENGTH of 4“ (10.2 cm) Dia. RIGID METAL DUCT MAXIMUM LENGTH of 4“ (10.2 cm) Dia. FLEXIBLE METAL DUCT PREFERRED VENT HOOD TYPE PREFERRED VENT HOOD TYPE 4” (10.2 cm) Louvered 4” (10.2 cm) Louvered Number of Number of 90° turns 2.5” 90° turns 2.5” 4” (6.35 4” (6.35 (10.2 cm) cm) (10.2 cm) cm) 0 60’ (18.28 m) 48’ (14.63 m) 0 30’ (9.14 m) 18’ (5.49 m) 1 52’ (15.84 m) 40’ (12.19 m) 1 22’ (6.71 m) 14’ (4.27 m) 2 44’ (13.41 m) 32’ (9.75 m) 2 14’ (4.27 m) 10’ (3.05 m) 3 32’ (9.75 m) 24’ (7.31 m) 3 not recommended 4 28’ (8.53 m) 16’ (4.87 m) CORRECT INCORRECT INSTALL MALE FITTINGS IN CORRECT DIRECTION Exhaust Direction All dryers shipped from the factory are set up for rear Same as EXHAUST DUCT LOCATING exhausting. However, on ELECTRIC DRYERS, exhausting other side DIMENSIONS can be on the right or left side of the cabinet or the 5-7/8″ (15 cm) bottom of the dryer. On GAS DRYERS, exhausting can 4-3/8″ be on the right side of the cabinet or the bottom of the 13-1/2″ (11 cm) (34 cm) dryer. Directional exhausting can be accomplished by installing Exhaust Kit, Pub. No. 14-A018, available through your parts distributor. Follow the instructions supplied with the kit. Use only metal ducting inside the dryer cabinet. 3-3/4″ (9.5 cm) 3-3/4″ (9.5 cm) Gas Supply Requirements Replace brass connecting pipe that is not plastic4 The gas supply line MUST have an individual coated. Stainless steel or plastic-coated brass shutoff valve. MUST be used. 5 A 1/8″ (0.32 cm) NPT minimum plugged WARNING: Never reuse old flexible connectors. tapping, accessible for test gauge connection, The use of old flexible connectors can cause gas MUST be installed immediately upstream of the leaks and personal injury. Always use NEW flexible gas supply connection to the dryer. connectors when installing a gas appliance. 6 The dryer and its individual shutoff valve MUST 1 Installation MUST conform with local codes, or in be disconnected from the gas supply piping the absence of local codes, with the National Fuel system during any pressure testing of the gas Gas Code, ANSI Z223.1 (latest edition). supply piping system at test pressures in excess of 1/2 psig (3.45 kPa). 2 The gas supply line should be of 1/2″ (1.27 cm) rigid pipe. 7 The dryer MUST be isolated from the gas supply piping system by closing its individual manual 3 If codes allow, flexible metal tubing may be used shutoff valve during any pressure testing of the to connect your dryer to the gas supply line. The gas supply piping system at test pressures equal tubing MUST be constructed of stainless steel or 10 to or less than 1/2 psig (3.45 kPa). plastic-coated brass. Care and Cleaning Installation Instructions Customer Service
MAXIMUM LENGTH of 4“ (10.2 cm) Dia. RIGID METAL DUCT PREFERRED VENT HOOD TYPE Number of 90° turns4” (10.2 cm) 4” (10.2 cm)Louvered2.5” (6.35 cm) 060’ (18.28 m)48’ (14.63 m) 152’ (15.84 m)40’ (12.19 m) 244’ (13.41 m)32’ (9.75 m) 332’ (9.75 m)24’ (7.31 m) 428’ (8.53 m)16’ (4.87 m) CORRECT
MAXIMUM LENGTH of 4“ (10.2 cm) Dia. FLEXIBLE METAL DUCT PREFERRED VENT HOOD TYPE Number of 90° turns4” (10.2 cm) 4” (10.2 cm)Louvered2.5” (6.35 cm) 030’ (9.14 m)18’ (5.49 m) 122’ (6.71 m)14’ (4.27 m) 214’ (4.27 m)10’ (3.05 m) 3not recommended
Page 11 of the GE DCD330E user manual — FRONT SIDES REAR TOP
Page 11 · click to enlarge
Page 11

Location of Your Dryer

Do Not Install the Dryer:

Do not install the dryer in an area exposed to dripping water or outside weather conditions.

Floor MUST be solid with a maximum slope of 1″ (2.54 cm). 3

Do not install the dryer on carpet.

Do not install the dryer in an area where it will come in contact with curtains, drapes, or anything that will obstruct the flow of combustion and ventilation air.

Installation in Recess or Closet

This dryer MUST be exhausted outdoors.

Allow the following clearances for ease of installation:

No other fuel burning appliance shall be installed in the same closet as the GAS DRYER.

FRONT SIDES REAR TOP

Alcove 0 (0 cm) 0 (0 cm) 0 (0 cm) 15″ (38.1 cm)

Your dryer needs the space around it for proper ventilation. DO NOT INSTALL YOUR DRYER IN A CLOSET WITH A SOLID DOOR.

Closet 1″ (2.54 cm) 0 (0 cm) 0 (0 cm) 15″ (38.1 cm)

Closet door ventilation required: 2 louvered openings each 60 square inches (387.1 square cm) —3″ (7.6 cm) from bottom and top of door. 4

A minimum of 120 square inches (774.2 square cm) of opening, equally divided at the top and bottom of the door, is required. Air openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable.

0" (0 cm) 1" (2.54 cm) 15" (38.1 cm)

60 sq. in. (387.1 sq. cm)

60 sq. in. (387.1 sq. cm)

0" (0 cm) · Closet door

Page 12 of the GE DCD330E user manual — REAR VIEW SIDE VIEW
Page 12 · click to enlarge
Page 12

Installing the dryer (cont.).

Mobile Home Installation

Dryer MUST be exhausted outside (outdoors, not beneath the mobile home) using metal ducting that will not support combustion. Metal ducting must be 4″ (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred.

Installation MUST conform to current Manufactured Home Construction & Safety Standard (which is a Federal Regulation Title 24 CFR—Part 32–80) or, when such standard is not applicable, with American National Standard for Mobile Homes.

If dryer is exhausted through the floor and area beneath the mobile home is enclosed, the exhaust system MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure.

Correct

When installing a gas dryer into a mobile home, a provision must be made for outside make-up air. This provision is to be not less than twice the area of the dryer exhaust outlet.

Incorrect

This dryer MUST be fastened to the floor. Mobile Home Installation Kit Pub. No. 14-D346-33 is available from your dealer.

See the Exhaust System Requirements section for other important venting information.

The dryer is designed for use under ANSI Z 21.5.1.

Rough-In Dimensions

26 7/8″ (68.3 cm)

47 1/2″ (120.7 cm)

2 9/16″ (6.5 cm)

43 5/8″ (110.7 cm)

13 1/2″ (34.4 cm)

4 3/8″ (11.1 cm)

36″ (91.5 cm)

3/8″ (0.96 cm) Dia. gas pipe 1″ (2.54 cm) 3 3/4″ (9.5 cm) 3 3/4″ (9.5 cm)

27″ (68.6 cm)

REAR VIEW SIDE VIEW

Servicing – Consideration must be given to provide adequate clearances for installation and servicing.

Show 6 more labels / short text on this page
Do Do Do · Don’t Don’t Don’t · Door open · Electrical connection · 90˚ · Optional vent knockout
Page 13 of the GE DCD330E user manual — Grounding Requirements
Page 13 · click to enlarge
Page 13

Electrical Installation for Electric Dryers

of power cord to be purchased and allowing some slack in the cord. Refer to Electrical Requirements in this manual for the proper power cord to be purchased.

the cord, resulting in electrical shock.

will have longer drying times than those operating on 240-volt power supply.

A wiring diagram is located inside the control panel.

Grounding Requirements

For a permanently-connected electric dryer:

IThe dryer MUST be connected to a grounded

metal, permanent wiring system; or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance.

Grounding must be in accordance with local codes and ordinances, or in the absence of local codes, in accordance with the National Electrical Code ANSI/NFPA No. 70.

For a cord-connected gas dryer:

IThis dryer is equipped with a three-prong

For a grounded, cord-connected electric dryer:

(grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. 2

The dryer MUST be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electrical shock by creating a path of least resistance for electrical current.

If your dryer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug MUST be plugged into an appropriate, copper- wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances. If in doubt, call a licensed electrician.

Page 14 of the GE DCD330E user manual — Reinstall the terminal block access cover. 10 9
Page 14 · click to enlarge
Page 14

Installing the dryer (cont.).

3-Wire System for Electric Dryers—DO NOT use for Mobile Home Installations

Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner.

Attach the power cord neutral (center wire) conductor to the silver-colored center terminal on the terminal block. Tighten the screw securely.

Install a UL-approved strain relief into the power cord entry hole of the mounting bracket. Use a strain relief which attaches to the mounting bracket with a nut. Finger-tighten the nut only at this time.

Attach the remaining two power cord outer conductors to the outer brass-colored terminals on the terminal block. Tighten both screws securely.

Thread a UL-approved 30A, 240V, 3 #10 AWG minimum copper conductor power cord through the strain relief.

Reattach the strain relief mounting bracket to the back of the dryer with one screw. Tighten screw securely.

GE DCD330E — 3-Wire System for Electric Dryers—DO NOT use for Mobile Home Installations diagram (page 14)
Fig. 1 · 3-Wire System for Electric Dryers—DO NOT use for Mob…

Green ground screw Silver terminal

Tighten the screws securing the cord restraint firmly against the power cord.

Tighten the strain relief nut securely so that the strain relief does not turn.

Green neutral ground wire

Tighten nut to these threads

Reinstall the terminal block access cover. 9

Use copper conductors only.

Power cord Strain relief mounting bracket

4-Wire System for Electric Dryers—MUST be used for Mobile Home Installations

Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner.

Attach the red and black power cord conductors to the outer brass-colored terminals on the terminal block.

GE DCD330E — 4-Wire System for Electric Dryers—MUST be used for Mobile Home Installations diagram (page 14)
Fig. 2 · 4-Wire System for Electric Dryers—MUST be used for M…

Green power cord ground wire

Install a UL-approved strain relief in the entry hole of the mounting bracket. Use a strain relief which attaches to the mounting bracket with a nut. Finger-tighten the nut only at this time.

Green neutral ground wire

Remove the green neutral ground wire from the green ground screw located above the terminal block.

Nut Tighten nut to these threads

Strain relief mounting bracket

Typical 4 conductor receptacle

Typical 4 conductor cord

Thread a UL-approved 30A, 240V, 4 #10 AWG minimum copper conductor power cord through the strain relief.

Tighten the screws securing the cord restraint

firmly against the power cord.

Tighten the strain relief nut securely so the strain relief does not turn.

Attach the green power cord ground wire to the cabinet with the green ground screw.

Reinstall the terminal block access cover. 10 9

Attach the white (neutral) power cord conductor from the power cord and the green ground wire from the dryer harness to the silver- colored center terminal on the terminal block. Tighten the screw securely.

Show 12 more labels / short text on this page
Nut · Green ground screw · Silver terminal · Terminal block · Black · White · Red · Black 240V · Power cord · White neutral · Red 240V · Green ground
Page 15 of the GE DCD330E user manual — Replacement Parts
Page 15 · click to enlarge
Page 15

Gas Connection for Gas Dryers

Remove the shipping cap from gas pipe at the

Open the shutoff valve in the gas supply line.

rear of the dryer.

Test all connections by brushing on a soapy water solution.

NOTE: On gas dryers, before the burner will light, it is necessary for the gas line to be bled of air. If the burner does not light within 45 seconds the first time the dryer is turned on, the safety switch will shut the burner off. If this happens, turn the dryer off and wait 5 minutes before making another attempt to light.

Connect a 1/2″ (1.27 cm) I.D. semi-rigid or approved pipe from gas supply line to the 3/8″ (0.96 cm) pipe located on the back of the dryer. Use a 1/2″ to 3/8″ (1.27 cm to 0.96 cm) reducer for a connection. Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections.

Before Operating the Dryer

Connect the exhaust duct to outside exhaust system. Use duct tape to seal all joints.

With the dryer in its final position, adjust one or more of the legs until the dryer is resting solidly on all four legs. Place a level on top of the dryer. THE DRYER MUST BE LEVEL AND RESTING SOLIDLY ON ALL FOUR LEGS. Turn the lock nuts on each of the four legs up toward the base of the dryer and snug with a 1/2″ open-end wrench.

Run the dryer through a cycle check for proper operation.

Place these instructions in a location near the dryer for future reference. 6

Plug the power cord into a grounded outlet. NOTE: Check to ensure the power is off at circuit breaker/fuse box before plugging the power cord into the outlet.

Turn on the power at the circuit breaker/fuse box.

Replacement Parts

If replacement parts are needed for your dryer, contact the source where you purchased your dryer.

Page 16 of the GE DCD330E user manual — Reversing the Dryer Door Swing
Page 16 · click to enlarge
Page 16

Installing the dryer (cont.).

Reversing the Dryer Door Swing

Open the dryer door. Remove the 4 hinge hole plugs or screws from the left side of door opening. Place nearby for future installation. NOTE: You may need a plastic knife to help pull out the plugs. Be careful not to scratch the paint.

Remove the four screws that secure the door hinges to the dryer front panel. NOTE: Remove 1 screw from each of the 2 hinges first. Hold the door firmly before removing the last 2 screws.

Rotate the door 180° and reinstall the door hinges to the dryer front panel with the 4 screws.

Remove 4 screws—one from each hinge first

Install the 4 hinge hole plugs or screws that were removed in step 1 into the open screw holes on the right side of the door opening. 4

Page 17 of the GE DCD330E user manual — DIP SWITCH NUMBERS
Page 17 · click to enlarge
Page 17

Countdown Display (DCD models only)

The countdown display shows the remaining operating time as well as the current drying cycle. The display board is configured for a 45-minute dry time at the factory to correspond with the 45-minute

timer cam pre-installed in the coin box. If the timer cam is modified for another operating duration, the dipswitches on the display board should be set as follows:

DIP SWITCH NUMBERS

DRYING TIME (minutes) 1 2

DIPSWITCH SETTING (min) COIN SLIDE ACTUATIONS DISPLAY READING (min)

45 1 45 to 0, then blank

45 2 45 to 1, then 1 for next 45 min., then 0 and blank

120 1 99 for 21 minutes, then 98 to 0, then blank

120 0 0

Page 18 of the GE DCD330E user manual — Notes
Page 18 · click to enlarge
Page 18

Notes

Page 19 of the GE DCD330E user manual — Countdown Display
Page 19 · click to enlarge
Page 19
Page 19 of the GE DCD330E user manual — Countdown Display
Page 20 of the GE DCD330E user manual — Warrantor: General Electric Company. Louisville, KY 40225
Page 20 · click to enlarge
Page 20

GE Commercial Dryer Warranty

Parts and service are available from your General Electric Commercial Laundry distributor.

For The Period Of: GE Will Replace:

Three Years Any part of the dryer which fails due to a defect in materials or workmanship, except the drop From the date of the coin meter, coin slide mechanism, coin vault and locks, which are excluded from this warranty. original purchase During this limited three-year warranty, any related service, labor and diagnostic calls are not included.

What GE Will Not Cover:

IService trips to your place of business to teach you how to

IReplacement of fuses or resetting of circuit breakers at

use the product.

place of business.

IImproper installation.

IDamage to the product caused by accident, fire, floods or

IFailure of the product if it is abused, misused, or used for

acts of God.

IIncidental or consequential damage to personal property

other than the intended purpose.

caused by possible defects with this appliance.

IAny and all implied warranties of merchantability and

fitness for a particular purpose are hereby excluded.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for commercial use within the USA. In Alaska, the warranty excludes the cost of shipping to your place of business.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor: General Electric Company. Louisville, KY 40225

Printed in the United States

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the GE DCD330E

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE DCD330E

Be the first to ask — other owners or our team will answer.

Original document

GE DCD330E manual PDF

20 pages·635 KB·Clothes Dryer·PDF
Click any page above to open it here
Page 1 / …
100%