h) NEVER place a switch where it can be reached from the tub or shower.
To ensure the best air and sound performance, it is recommended that the length of ducting and the number of elbows be kept to a minimum, and that insulated hard ducting be used. Larger duct sizes will reduce noise and airflow restriction.
Before beginning this installation remove the fan’s blower housing (which includes the motor, blade, bracket and venturi) assembly by removing the screw which secures the venturi housing to the fan housing (Fig. 1). Place this assembly and the grill in the carton until needed so they do not get damaged. Mounting the Housing: New Construction

Acceptable for use over tub or shower when installed in a GFCI protected branch circuit.
a) Use this unit only in the manner intended by the manufacturer. If you have any questions,
please contact the manufacturer. b) Before servicing or cleaning unit, switch power to off at service panel and lock the service
Using the Hanging Brackets (refer to Fig. 2) 1. Insert the hanging brackets in the slots provided in the housing. 2. Remove the electrical cover (which holds the fan’s receptacle) and place it somewhere handy. Select the most convenient electrical knockout and remove it, then locate the fan housing between the joists so that the bottom of the fan housing is even with the planned finished ceiling. 3. Use screws or nails (not provided) to secure the hanger bars to the ceiling joists. Mounting the Housing: Existing Construction
disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. c) Do not install this fan in a ceiling thermally insulated to a value greater than R-40 d) Installation work and electrical wiring must be done by qualified, competent, trained
person(s) in accordance with all applicable codes and standards using proper safety practices, including fire-related construction. e) Sufficient air is needed for proper combustion and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Agency (NFPA) and the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities. f) When cutting or drilling into a wall or ceiling, ALWAYS identify hidden electrical wiring
and other hidden utilities in advance, to avoid damage. g) Ducted fans must always be vented to the outdoors.

2. Where you have access inside the fan’s junction box, connect the white wire from the house to the white wire of the fan’s receptacle. Connect the black wire from the fan switch to the black wire of the fan’s receptacle (use approved electrical connectors). Connect the ground wire to the green ground screw in the fan’s junction box. Replace the fan’s wire compartment cover. Completing the Installation 1. After you have installed the housing in the ceiling, run ducting from the unit to the outside and have made the necessary electrical connections you can reinstall the venturi and blower in the fan housing (Fig. 3). Plug the fan’s blower assembly into the fan’s receptacle and secure the blower housing with the screw removed earlier. Rotate the blower wheel by hand to ensure it revolves freely. 2. To install the grill, squeeze the two ends of each spring fastener together and insert each into the slots on the venturi. Push the grill up to the ceiling.
Note: All ducting must comply with local and national building codes. 1. Connect the ducting to the fan's duct collar. Secure in place using duct tape or screw clamp. Always duct the fan to the outside through a wall or roof cap. To ensure maximum air delivery, keep the length of duct and number of elbows to a minimum. Electrical Wiring WARNING: POWER MUST BE PROVEN DISCONNECTED BEFORE STARTING INSTALLATION, INSPECTION OR MAINTENANCE! FAILURE TO DO SO MAY CAUSE SERIOUS INJURY, DEATH AND/OR PROPERTY DAMAGE. Caution: Make sure power is switched off at service panel before beginning this installation. Note: All wiring must comply with local and national codes. You must ground this unit.
Warranty WHAT IS COVERED? Full One Year Parts Warranty from date of original proof of purchase. We will provide, free of charge, a replacement part that fails due to manufacturing defect in material or workmanship, when installed and used as directed in the User’s Guide. This warranty is extended to the original purchaser for products purchased for ordinary home use.
This warranty contains the sole and exclusive warranty of GE for claims based on defects in these products. Upon the expiration of the warranty period, all such liability shall terminate. There are no other warranties, whether written, oral, implied or statutory. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY.
IN NO EVENT SHALL GE BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, INDIRECT, OR INCIDENTAL DAMAGES, SUCH AS, BUT NOT LIMITED TO, LOSS OF PROFIT OR REVENUES, LOSS OF USE OF THE PRODUCTS OR ANY ASSOCIATED EQUIPMENT, DAMAGE TO ASSOCIATED EQUIPMENT, OR COST OF SUBSTITUTE PRODUCTS.
IN NO EVENT, SHALL GE’S LIABILITY TO BUYER FROM THE SALE OF THESE PRODUCTS EXCEED THE PRICE OF THE DEFECTIVE PRODUCT SOLD AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.
Read your User’s Guide. If you have any questions about operating the product, please contact your dealer.
Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province.