Industrial Computers
Intelligence Panel PC Models IC5002, IC5005, IC5008, BC5002, BC5005, BC5008
User's Manual
GFK-2023C August 2003

as Used in this Publication
In situations where inattention could cause either personal injury or damage to equipment, a Warning notice is used.
This document is based on information available at the time of its publication. While efforts have been made to be accurate, the information contained herein does not purport to cover all details or variations in hardware or software, nor to provide for every possible contingency in connection with installation, operation, or maintenance. Features may be described herein which are not present in all hardware and software systems. GE Fanuc Automation assumes no obligation of notice to holders of this document with respect to changes subsequently made.
GE Fanuc Automation makes no representation or warranty, expressed, implied, or statutory with respect to, and assumes no responsibility for the accuracy, completeness, sufficiency, or usefulness of the information contained herein. No warranties of merchantability or fitness for purpose shall apply.
The following are trademarks of GE Fanuc Automation North America, Inc.
Alarm Master Genius PROMACRO Series Six CIMPLICITY Helpmate PowerMotion Series Three CIMPLICITY 90–ADS Logicmaster PowerTRAC VersaMax CIMSTAR Modelmaster Series 90 VersaPro Field Control Motion Mate Series Five VuMaster GEnet ProLoop Series One Workmaster
©Copyright 2001—2003 GE Fanuc Automation North America, Inc.
All Rights Reserved.

Content of This Manual
This manual describes the features and operation of the following industrial computer products:
Model Features Model Features
IC5002 12.1" Flat panel display BC5002 12.1" Flat panel display with bundled software IC5005 15" Flat panel display BC5005 15" Flat panel display with bundled software IC5008 18" Flat panel display BC5008 18" Flat panel display with bundled software
GFK-1868 CIMPLICITY Machine Edition Getting Started Manual
GFK-1180 CIMPLICITY HMI Plant Edition Base System User's Manual (2 vols)
GFK-2023C iii




Chapter
The Intelligence Panel industrial PC is designed to meet the demands of advanced control and monitoring architectures. All GE Fanuc industrial computers meet industrial requirements for factory automation applications, including extended temperature, shock and vibration, and NEMA 4 sealed front panels. Coupling the industrial packaging with the latest in processor technology and state-of-the-art flat-panel displays, this industrial PC delivers outstanding performance to the factory floor.
Available in 12", 15" or 18" flat panel displays with active matrix Thin Film Transistor (TFT) technology, the Intelligence Panel PC provides installation flexibility and wide viewing angles for the most demanding industrial applications. Intelligence Panel PC is available as a stand-alone product, or bundled with HMI/Control or HMI/SCADA software offerings.

The Intelligence Panel PC is available as a bundled system with the HMI or Control application software of your choice, such as CIMPLICITY® HMI, Intellution iFIX, or CIMPLICITY Machine Edition, launched from Windows NT® or Windows® 2000 operating systems. Whatever your choices, powerful processors with PCI and ISA backplanes are standard in every Intelligence Panel PC. To save you time and money, GE Fanuc integrates and tests the powerful hardware and software combination on the Intelligence Panel PC at our factory.
The Intelligence Panel PC fits seamlessly into your control application and accommodates your ever-changing industrial requirements. End users, OEM, and system integrators will see a single integrated hardware and software platform that provides a scalable computing platform from the factory floor devices to the business enterprise at a lower cost.
The Intelligence Panel PC bundled with Machine Edition software offers a true out-of-the- box Web-enabled solution for machine and process level HMI and PC-based control applications. Incorporating a single user interface, Machine Edition hosts several development and runtime engines within a common environment. Operator interface and PC-based motion control programming are just a few of the included components.
Machine Edition comes with run-time and development software. There are two options available:
GE Fanuc’s Intelligence solutions are the ideal platform for visualization, automation and control. iFIX and CIMPLICITY HMI software products combine our rugged hardware units with our powerful software applications and are designed to uniquely suit your needs for process or discrete environments.
iFIX, with an information rich automation oriented Function Block Database combined with a robust and extensible graphics environment, is an ideal option for meeting all your supervisory control and data acquisition needs.
iFIX functionality includes features created specifically to address the electronic signature and advanced audit trail needs of regulated industries. This added functionality empowers you to introduce new levels of security and accountability into any application in your organization, regardless of industry. Some markets ideally suited to iFIX include water/wastewater, food and beverage, pharmaceutical, metals, oil and gas, mining and others with a process orientation.
CIMPLICITY HMI provides advanced functionality that establishes a solid foundation for a robust, powerful HMI interface and is the best option for applications with a greater

discrete manufacturing orientation. A true client/server architecture and open-system design offers fast, easy integration. CIMPLICITY HMI gives you the ability to grow from a single computer node to a plant-wide monitoring and control system providing real-time information from the factory floor to all levels of the enterprise.
CIMPLICITY HMI offers powerful operator interface and machine control functionality. Several markets and applications that are ideally suited to CIMPLICITY HMI include automotive, aerospace, plant floor, HMIs, discrete manufacturing, machining, semiconductor, CNC, Motion Control, and Consumer Packaged Goods among others.
Both products use the latest web technologies to provide you with visibility into the key metrics you need to run your manufacturing operations efficiently and effectively. This data can made available to one of the many web-enabled display devices on the market today. Whether it is a standard web browser, hand-held PDA, wireless bar code reader or industrial hardened CE device, you get real-time access to the important information needed to operate your business.
GFK-2023C Chapter 1 Product Features 1-3

GE Fanuc provides a single resource for all your services and support needs including technical software support, product training, and complete application consultation and development services.

Diagonal 307.4 mm (12.1") 383.5 mm (15.1") 459.7 mm (18.1")
Resolution (Pixel) SVGA (800 x 600) XGA (1024 x 768) SXGA (1280 x 1024)
VGA controller (AGP 1x) 2MB SDRAM (AGP 1x) 2MB SDRAM (AGP 1x) 4MB SDRAM
Touch Screen Analog. 5 wire resistive with serial interface internal connected to COM4
Slot-CPU All in Passive PCI/ISA bus slot CPU with FCPGA-Socket for Intel processor
Storage Hard disk min. 40 GB minimum (3.5" UDMA)
48 watt (typical) 60 watt max. 54 watt (typical) 62 watt max. 67 watt (typical) 75 watt max.

Chapter
This equipment carries electric currents and contains highly- sensitive components. Other than plugging in additional cards or modules, you should not attempt modifications to the unit. If other modifications need to be made, the manufacturer or an authorized service agent must be contacted. The unit must be switched off at the main power supply and the power cable disconnected during such work. Suitable precautions must be taken to avoid electrostatic discharge on contact with components. If an unauthorized person opens the product case, danger to the user may arise and the warranty will be void.
To prevent damage to the unit, do not attempt to connect leads (power supply and port cables) unless the unit is switched off.
The Intelligence Panel is designed for installation in a metal cabinet. The ambient conditions specified in chapter 8, “Technical Data” must be maintained. Installation in an environment not specified in Technical Data, for example exposed to extended temperatures or at extreme altitudes, may void the warranty.
When installing the unit in an environment where there is the potential for flammable gases, vapors or liquids to be present, the power cable must be secured to the unit using the enclosed cable clamp kit. In addition, the power cable must have the male plug removed and be permanently hard-wired to the AC source. For details, refer to “Hazardous Locations Installation” in chapter 3.

If the Intelligence Panel displays signs of damage caused by inappropriate operating/storage conditions, mounting, or incorrect handling, the unit must be taken out of use immediately and secured against unintentional operation.
Repairs under warranty may only be made by the manufacturer or by agents authorized by the manufacturer.
For return authorization, contact 1-800-432-7521 Customer Service. Be prepared to provide delivery date, product model, customer order number, unit serial number, and reason for return request.
Units must be returned to the factory in the original shipping container. If you do not have the original shipping container, contact GE Fanuc Customer Care to order a new shipping container. . The part numbers are 44B714940-001R01 (Carton) and 44B714939- 001R01 (Insert). For proper shipping one carton and two inserts are required. If the units are not returned in the original shipping container the warranty is voided.
If the product has incurred obvious damage during transportation, do not apply power
If the product has incurred obvious damage during transportation, you should avoid applying power. Obvious transport damage should be reported to the supplier immediately. Less obvious damage that becomes evident in the early operation of the product must be reported within five days of the initial delivery for consideration as transportation damage.

Chapter
Intelligence Panel PCs are designed for installation in switchboard panels and cabinet doors. To facilitate installation and access to connectors, switchboard panels and consoles must be accessible from the rear. The unit can be installed in switchgear cubicles or cabinets with wall thicknesses of 2mm to 13mm (0.079 – 0.5 inches). For optimum sealing with the cabinet face, the recommended wall thickness is 3mm (0.118 inches).
Air Inlets and outlets must have at least 25mm (approx. 1.0 inch) of space around them and not be obstructed. Adequate airflow around the exterior of the unit is important to the interior temperature of the unit. Two fans are used to create air flow through the industrial computer to maintain a correct working temperature.
Only correct mounting ensures front-side NEMA and IP65 protection
The IC5005/BC5005 and IC5008/BC5008 units must be installed and operated in a vertical position to ensure the correct operating position of the CD-ROM drive.
Viewed from the front, there must be sufficient space (132 mm or 5.20 in. minimum) to the left of the units to allow the CD-ROM drive drawer to open.

Over tightening the screws will cause irreparable damage to the front panel and break the touch screen itself.
Connect the provided power cord to the AC power supply. If additional grounding to a grounding screw is desired, use 14 AWG gauge wire minimum.
Table 3-1. Critical Dimensions for Installation
IC5008 BC5008
Cover (W x H) 313 x 252mm 23.3 x 9.9 in. 373.6 x 295.6 mm 14.7 x 11.6 in. 426 x 355mm 16.8 x 14.0 in.
Cutout (recess) (W x H)
318 x 256mm +1.0mm 12.5 x 10.1 in. + 0.04 in.
376 x 299mm +1.0mm 14.8 x 11.8 in. + 0.04 in.
428 x 358mm +1.0mm 16.9 x 14.0 in. + 0.04 in.
Space required for ventilation
Minimum 50mm (2 in) clearance at top and bottom of the unit. Minimum 30mm (1.2 in.) at sides. Note additional side space consideration is required for models with CD- ROM, depending on cabinet design. Viewed from the front, there must be sufficient space (132 mm or 5.20 in. minimum) to the left of the units to allow the CD-ROM drive drawer to open.
Mounting depth 177mm 6.97 in. 150mm 5.9 in. 154mm 6.1 in.
Dimension IC5002 BC5002

6x Mounting blocks M4
View from back side
313 x 252 mm (W x H) 83 mm Approximately 50 mm around the unit
Recess:
318 x 256 mm +1,0 (W x H)
132 mm CD Drawer Clearance
Outer edge of cover
Outer edge of recess
Figure 3-1. IC5002/BC5000 Installation Diagram
Outer edge of frontpanel
GFK-2023C Chapter 3 Installation 3-3
0 260 330

0 186 390 341
8x Mounting blocks M4
View from back side
373,6 x 295,6 mm (W x H) 150 mm Approximately 50 mm around the unit
Recess:
376 x 299 mm +1,0 (W x H)
132 mm CD Drawer Clearance
Outer edge of cover
Outer edge of frontpanel Outer edge of recess Figure 3-2. IC5005/BC5005 Installation Diagram

0 221 442 402
8x Mounting blocks M4
View from back side
426 x 355 mm (W x H) 154 mm Approximately 50 mm around the unit
Recess:
428 x 358 mm +1,0 (W x H)
132 mm CD Drawer Clearance
Outer edge of cover
Outer edge of recess Figure 3-3. IC5008/BC5008 Installation Diagram
Outer edge of frontpanel
GFK-2023C Chapter 3 Installation 3-5
185,5 · 199,5

When installing the unit in an environment where there is the potential for flammable gases, vapors or liquids to be present the power cable must be secured to the unit using the enclosed cable clamp kit. In addition, the power cable must have the male plug removed and be permanently hard-wired to the AC source.
Mounting holes for cable clamp

Figure 3-4. Cable Clamp Mounting for Power Cable
Power connector

Hazardous (Classified) Location Class I, Division 2 Groups A, B, C, and D
Front USB Port on Computer No
(Computer) Vmax Imax Ci Li
Voc Isc Ca La
Voc = 4.969 VDC
Isc = 2.06 A
Ca = 75 µF
La = 40 µH
Ca ≥ Ci + C cable
La ≥ Li + L cable
Capacitance – 60 pF/ft
Inductive – 0.20 µH/ft
GFK-2023C Chapter 3 Installation 3-7

Chapter
PCI bus or ISA bus plug-in modules, such as network or field bus cards, can be installed in the Intelligence Panel. The plug-in slots are accessed by removing the rear cover, which is secured by cross-head screws.
The components in Intelligence Panel PCs are susceptible to electrostatic discharge (ESD) and can be functionally damaged by incorrect handling. The same applies to plug-in modules. It is therefore vital that suitable precautionary measures are taken to avoid electrostatic discharges on contact with the components.
To avoid a risk of electric shock, turn off power to the industrial computer and disconnect the power supply before removing the rear panel.

The rear cover is connected to the base units of the Intelligence Panel by a plug-in ground connector and cable. Carefully remove and orient the rear cover to avoid applying unnecessary tension on this cable.
All the expansion slots in the system allow the card to be clamped into place using standard PC card clamping.
Cover plates are fitted to each unused card position. These plates can be removed as necessary to install new cards. Any empty slots must have a cover plate fitted, otherwise agency approvals become invalid.

For most applications, an interrupt request (IRQ) or address cannot be shared by more than one resource. If more than one resource is set to the same IRQ or address, the application may not respond properly and could cause your machine to lock up. Following these instructions when installing Legacy ISA cards will prevent problems with resource conflicts.
The controllers (Ethernet, IDE) in the slot CPU of the IPC are connected via an internal PCI bus. This ensures that addresses and IRQs are automatically determined by the BIOS. When making changes to the configuration or adding ISA cards:
Legacy ISA cards are the oldest standard and require memory, I/O, and IRQ settings to be manually set on the card using jumpers, DIP switches, or a configuration program. The card and system need to have the same hardware settings.
The GE Fanuc web site http://gefanuc.com/ provides current information on BIOS settings for IRQs.
GFK-2023C Chapter 4 Installing Plug-in Modules 4-3

Table 4-1. Intelligence Panel I/O Port Range Table

Chapter
This chapter covers the following topics:
Installation of the Intelligence Panel in hazardous locations requires the use of a cable mounting clamp with the power connector. For instructions for installing this clamp, refer to “Hazardous Locations Installation” in Chapter 3.
To prevent damage, do not attempt to connect leads unless the unit is switched off.

Connecting a PS/2 keyboard and mouse is recommended before you get started. You need a PS/2 keyboard for convenience. An alternate approach is to use the soft keyboard and touch panel.
run CIMPLICITY HMI software. Each computer on a network must have a unique name.
allows the system to boot into Windows NT without your having to use a keyboard to press CTRL-ALT-DEL.
Subnet is 255.0.0.0. If necessary, consult your network administrator to select appropriate addresses.

Connecting a PS/2 keyboard and Mouse is recommended before you get started. You need a PS/2 keyboard for convenience. The soft keyboard and touch panel will not work until the Windows 2000 operating system is licensed. Therefore an external keyboard is required to license the product.
HMI software. Each computer on a network must have a unique name.
At the end of the setup process, you will be asked to reboot the system. Press Finish.
After restarting, you will need to configure the login settings for Windows 2000. When the “Network Identification Wizard” dialog box appears press Next >.
The “Users of This Computer” dialog box appears.
GFK-2023C Chapter 5 System Operation 5-3

With Windows NT, if you type admin as your Administrator password, your industrial computer will automatically log on as Administrator.
Log onto the system as Administrator when you power up the system. Doing so eliminates the requirement to log on to CIMPLICITY when you run the CIMPLICITY Demo or any other CIMPLICITY project that includes a user named Administrator. All CIMPLICITY projects are configured with an Administrator user by default.
The Windows operating system and GE Fanuc software (except IC850PCT400) are loaded onto the industrial computer at manufacture. If it is necessary to reload software, follow the instructions in the documentation supplied with the software.
To avoid damaging files, always shut down Windows Operating System before removing power from your Intelligence Panel.
To shut down Windows Operating System, select the Start menu and choose Shut Down.

The IPC features a hidden partition on the hard drive that contains an OS recovery image. This image can be used to recover a corrupt OS.
Instructions for OS recovery:
Before attempting an Image Recovery on your unit, make sure to record all critical settings and conduct a full back up of all software projects and critical documents. You will also need to have your software (CIMPLICITY software product) registration and Microsoft Authorization Numbers handy. This process will clear all contents from your Hard Drive and return your system to the factory configuration.
− On Windows 2000 units, the license is on the back of the unit.
− On Windows NT units, the license is provided on the supplied OS packet.
MS-DOS is a registered trademark of Microsoft Corporation.
GFK-2023C Chapter 5 System Operation 5-5

Chapter
Control Keys
Intelligence Panel PCs are shipped with the Windows NT or Windows 2000 operating system installed. Additional pre-installed software includes drivers to support the virtual keyboard. In case you need to re-install the software, CDs and floppy disks are included with the appropriate drivers.
The five keys on the front panel are assigned the following default functions.
Opens and closes the virtual keyboard to allow character input via the TouchScreen With SHIFT key: No function.
Switches tasks (ALT+ESC) in Windows. With SHIFT key: No function.
Hot Keys: Launches application - Starts the text editor (Notepad) as the default. With SHIFT key: Increases display brightness.
Right mouse key function. With SHIFT key: Decreases display brightness.
SHIFT key for upper case. The SHIFT key must be pressed at the same time as the desired function key.
The general system keys can be disabled or configured to launch an application or tool through an .ini file. For information on application instructions, see the GE Fanuc web site http://gefanuc.com/
the settings can be found in the README file on the floppy disk.

A virtual keyboard that allows you to enter data using the TouchScreen in a similar way to a normal keyboard is supplied with the Intelligence Panel. If the Intelligence Panel is delivered without an installed operating system, you can install the Softkeyboard using the floppy disk provided (see chapter 7, “Driver Installation”). This also automatically installs the keyboard assignment for the five keys below the display at the front.
standard keyboard (e.g. ALT + F4), these keys have to be pressed one after the other on the virtual keyboard. The special SHIFT, ALT and CTRL keys always have to be pressed first.
guaranteed that the virtual keyboard will be compatible with all software.
Increases the size of the Softkeyboard display
Decreases the size of the Softkeyboard display
Free area Moves the virtual keyboard on the screen
A 6-pin mini-DIN Keyboard socket (PS/2) is located on the side of the operating console. Industry-standard, AT-compatible quality keyboards with the appropriate connector can be plugged into this socket. The suitability of keyboards must be checked before installation.
a limited range of controls are available on the external keyboard.

When the SHIFT key is used to adjust the display settings, the LED goes out. If one of the other four keys is also pressed, the LED flashes until the limit of the adjustment range is reached.
The following modes are also displayed:
therefore displayed if both errors occur.
Overheating and Fan Speed LED signals can only be reset by restarting the computer.
When using CIMPLICITY Machine Edition or CIMPLICITY HMI, an OPC driver is provided to monitor the PC condition through system status variables. The following features can be monitored:
The operating console is provided with the analog TouchScreen with serial controller, which is connected internally to the COM4 serial port. To be able to use the TouchScreen, the driver software must be integrated in the relevant operating system (see “TouchScreen Driver Installation” in chapter 7).
GFK-2023C Chapter 6 Controls 6-3

A Microsoft-compatible mouse with PS/2 connector can be attached to the Mouse port. The compatibility of the mouse must be checked before use. The mouse can be used in addition to the TouchScreen.
port during installation as the TouchScreen is not yet usable. This considerably simplifies the process of initial installation of the operating system. The mouse can be removed later without an error message.
The hard disk is fitted to a mounting plate with vibration-damping rubber elements. A 3.5" Ultra-DMA hard disk with commonly available capacity (minimum of 20 GB) is provided.
The floppy disk drive is fitted on the left of the operating console (viewed from the front) next to the Intelligence Panel ports.
The CD-ROM drive is on the left of the operating console (viewed from the front) under and next to the Intelligence Panel ports. The CD-ROM drive cannot be opened unless the Intelligence Panel is switched on. Pressing the Eject button activates a motor that opens the drawer. The drawer can be closed again by pushing the drawer gently or by pressing the Eject button.
To avoid damage to the drive, ensure that the motorized drawer is not obstructed as it opens. (See “Installation Procedures” in chapter 3.)

A USB port is provided on the front of the operating console. All other ports are arranged in the housing on the left of the operating console (viewed from the front). All ports are labeled. For pin assignments, refer to chapter 8, “Technical Data”.
To prevent damage to the unit, do not attempt to connect leads unless the unit is switched off.


Figure 6-1. Front USB Port, All Units
COM 1
COM 3

CRT LPT 1
PS/2 Mouse PS/2 Keyboard
Figure 6-2. Expansion and Communications Ports, 12.1" Intelligence Panel
GFK-2023C Chapter 6 Controls 6-5
Ethernet

COM 1 Ethernet USB

COM 2
LPT 1
CD-ROM Drive PCI/ISA (2) and ISA slots
Figure 6-3. Expansion and Communications Ports, 15" and 18" Intelligence Panels
The Intelligence Panel can be integrated into an Ethernet supporting 10 or 100 Mbit/sec. using an appropriate network cable from the Ethernet network port (10/100Base-T). Network architecture specifications must be observed. The CD supplied with the unit contains drivers required for network operation, which must be installed according to the particular operating system (see Chapter 7, “Driver Installation”).
Floppy Disk Drive · PS/2 Keyboard · PS/2 Mouse

A CRT-Multisync monitor can be operated from the 15-pin monitor connection in parallel with the integral flat screen. The monitor must be capable of running at a minimum horizontal frequency between 31-69 kHz, otherwise the maximum resolution of 1280 x 1024 pixels cannot be displayed.
Do not connect a standard VGA monitor (horizontal frequency 31.5 kHz) as it will be damaged by timing changeovers!
The Intelligence Panel is fitted with an auto-switching power supply.
GFK-2023C Chapter 6 Controls 6-7

Chapter
Intelligence Panel PCs are shipped from the factory with the Windows operating system pre-installed. Depending on the product purchased, CIMPLICITY software is also preinstalled. For configurations where no operating system is installed or the operating system needs to be re-installed, you must perform a complete installation procedure and set up all necessary drivers. The original CDs and a Softkeyboard floppy disk are supplied with the unit.
mouse port because the TouchScreen is not yet usable. This simplifies the process of initial installation of the operating system. The mouse can be removed later without an error message.
To install the driver for the network card, the installation files from the CD "SBC Drivers, Utilities & User Manuals" (file path: CD:\SBC8260\DRIVER\LAN\WINNT) must be copied to the main directory of a floppy disk.
To install the integrated network port for Windows NT:

If selecting DHCP, the IPC must be connected to the DHCP- supported network.
Since Windows NT 4.0 installation only installs a standard VGA driver supplied by the operating system manufacturer, this needs to be replaced in order to make full use of the capabilities of the high-resolution flat screen. The driver can be found on the "SBC Drivers, Utilities & User Manuals CD). Installation is performed as follows:
For Windows NT, do not install the driver unless Service Pack 3 or higher has been installed since in earlier versions Windows does not support the AGP interface of the graphics card. Do not install the driver during initial installation of the operating system.
Remove the CD-ROM from the drive.

You will find drivers for the TouchScreen on the supplied "TouchTools CD from Elo TouchSystems.
During driver installation make sure that the TouchScreen is attached to the COM 4 (IRQ 10) serial port.
Installation is performed as follows:
GFK-2023C Chapter 7 Driver Installation 7-3

To ensure that the hard disk and CD-ROM drive run at maximum speed, the UDMA driver for the VIA chip set must be installed. The driver can be found on the “SBC Drivers, Utilities & User Manuals” CD. Installation is performed as follows:
Remove the CD-ROM from the drive.
To be able to use the five buttons on the front panel and to enter data using the software keyboard and TouchScreen, you need to install the software keyboard driver from the supplied disk. Installation is performed as follows:
For Windows NT version 4.0, do not install the driver unless Service Pack 5 or higher has been installed because there may be operating problems with earlier versions.

You can subsequently adapt the key assignment of your virtual keyboard to the standard layouts of other countries. The settings are stored in an INI file. To change the settings, you will need to modify the file in a text editor such as NotePad. This can be done as follows:
Information on altering the settings can be found in the README file on the floppy disk.
Installation and application instructions for copying files to a write-able CD are provided with the supplied CD Writer Utilities.
GFK-2023C Chapter 7 Driver Installation 7-5



warranty.

a. COM1/2 (RS232 16550 compatible) b. COM3 (RS232 16450 compatible) c. LPT1 d. Keyboard PS/2 e. Mouse PS/2 f. Monitor
48 watt (typical) 60 watt max. 54 watt (typical.) 62 watt max. 67 watt (typical.) 75 watt max.

The maximum power consumption of additional expansion cards should not exceed 20 watts to avoid overheating.
The IC5005/BC5005 and IC5008/BC5008 models support full length cards size (339 mm). The IC5002/BC5002 models support up to 290 mm cards size (3/4 ISA size).

330 x 268 x 183 mm 390 x 312 x 156 mm 442 x 371 x 160 mm
Mounting depth: 177 mm + 50 mm for cooling top and bottom 30 mm for cooling on sides
150 mm + 50 mm for cooling top and bottom 30 mm for cooling on sides
154 mm + 50 mm for cooling top and bottom 30 mm for cooling on sides

Shock: Operating 15G equivalent, 11ms, 3 axis pos. and neg. Non-operating 30G Reference IEC 68-2-27.
Vibration: Operating: 1G, 5 to 9 Hz; 1.0g 9 to 150 Hz. Non-operating: 2.5G, Reference IEC 68-2.
Agency Approvals UL 1604 Class 1 Div 2 CE
Electrostatic Discharge ESD EN 61000-4-2 Radiated Electromagnetic RF Fields EN 61000-4-3, ENV 50204 Fast transients BURST EN 61000-4-4 Conducted Electromagnetic RF-Fields EN 61000-4-6, ENV 50141
RF voltage EN 55011, EN 55022 RF fields EN 55011, EN 55022




GFK-2023C Chapter 8 Technical Data 8-3



The power supply input to the industrial computer uses a standard IEC cable, which is provided with the unit.

BIOS settings are available through the GE Fanuc web site URL http://gefanuc.com/
For current troubleshooting and frequently asked questions, go to the GE Fanuc web site URL: http://gefanuc.com/
The ACCU.PDF file in the \Docs\Manuals directory on the “Drivers” CD supplied for the Touchscreen contains a user manual in Adobe Acrobat format. You will need Acrobat Reader installed on your system to be able to view the manual (Acrobat Reader is included on the CD).
The “Troubleshooting” sections in the manual tell you how to check the drivers in the event of a malfunction of the Touchscreen.
GFK-2023C Chapter 8 Technical Data 8-5

M
pin assignments, 8-3 port configurations, 8-3 standards, 8-2 Technical support, 1-4, 8-5 Touchscreen, 6-3
Machine Edition, 1-2 Modules
installation, 4-1 Monitor system
calibration, 5-4 driver, 7-3 troubleshooting, 8-5 Troubleshooting
technical data, 8-1 Mouse, 6-4
Intelligence Panel, 8-5 touchscreen, 8-5
Network adapter driver, 7-1 Networking, 6-6 Nonincendive field wiring, 3-7
UDMA driver, 7-4 USB port connections
Nonincendive field wiring, 3-7
Warranty and repairs, 2-2 Windows 2000 systems
setting up, 5-3 Windows NT systems
Pin assignments, 8-3 Port configurations, 8-3 Ports, 6-5 Power cable installation, 3-6 Power supply, 6-7
Read/write CD-ROM utilities, 7-5 Recovery, image, 5-5 Repairs, 2-2 Return authorization, 2-2
Setting up Windows 2000 systems, 5-3 Setting up Windows NT systems, 5-2 Shutting down the computer, 5-4 Slot cover plates, 4-2 Softkeyboard, 6-2
driver, 7-4 Standards, 8-2 Support, 1-4
dimensions, 8-2 environmental specifications, 8-2 expansion cards, 8-2 Industrial PC, 8-1 monitor system, 8-1
Index-2 Intelligence Panel PC User's Manual–August 2003 GFK-2023C