EN
GE logo
Official user manual

GE Digital Answering Machine (250D)

4 pages·248 KB·Network Hardware·PDF·ENDEFRITNLJA
GE Digital Answering Machine (250D)
Table of Contents 5 sections GE Security · 16-Channel Contact/TTL Data System Models 250D and 2250D installation instructions · 11-0250-251099-A · 250D and 2250D · … ShowHide
Page 1 of the GE Digital Answering Machine (250D) user manual — 11-0250-251099-A
Page 1 · click to enlarge
Page 1

GE Security

16-Channel Contact/TTL Data System Models 250D and 2250D installation instructions

GE Digital Answering Machine (250D) — GE Security diagram (page 1)
Fig. 1 · GE Security

11-0250-251099-A

Page 2 of the GE Digital Answering Machine (250D) user manual — 250D and 2250D
Page 2 · click to enlarge
Page 2

250D and 2250D

GE Digital Answering Machine (250D) — 250D and 2250D diagram (page 2)
Fig. 2 · 250D and 2250D

GENERAL The GE Security 250D system transmits up to 16 channels of low-speed digital data, switch/status information, or control/function signals. The user may program the receiver to provide 16 channels of alternate-action outputs , or eight channels of each type. Outputs are TTL drivers or N/O reed relays.

ABOUT THE SYSTEM Units are designed for rack mounting in the GE Security Card Cage, 517R Racking System, or in the 501R Miniature Enclosure. If you have ordered standalone units, they have been shipped in a 501R (figure 3, page 3).

Each unit occupies one card-cage slot. Units in the 515R or the 517R are powered from the rack. If using the 501R Miniature Rack, the GE Security power supply, model number 613P is required (ordered separately). Inputs to the transmitter, through the 44-pin connector, are normally held high to +5 volts by means of a 1K ohm pull-up resistor. A closure to ground or an open collector to ground will activate a particular channel. The receiver has a corresponding dry closure or TTL output for each channel. The relays are normally open and the TTL is normally low. Any number of channels up to 16 may be activated at any time. The transmitter’s closure need only be momentary, alternate action, or a combination of momentary and alternate action.

TTL OUTPUTS The receivers are set for relay operation at the factory. If TTL outputs are desired, four switches are provided to convert the channels to TTL in groups of four. Refer to figure 1 for the location of the switches.

OPTICAL INDICATORS Transmitters include a status LED which, when green, indicates data is being sent. Receivers include a LEVEL/LOSS indicator which is used to determine received optical power. This LED will glow green when sufficient optical power is received. If this LED is off, it indicates that optical power is not being received and would suggest that the fiber is open or, less likely, the transmitter or receiver is inoperative.

MOMENTARY OR ALTERNATE ACTION OPERATION Receiver outputs may be set in the field by the user for the desired operating conditions, either 16 channels of momentary operation, 16 channels of alternate action, or eight channels of each type. To make adjustments, locate jumpers E0 and E1 (figure 1 above) found near the 8031 processor on the receiver card. For 16 channels of momentary operation, remove both jumpers. For 16 channels of alternate action operation, install both jumpers. For 8 channels of each type of operation, remove the E0 jumper and install the E1 jumper. Units are shipped with both units installed (all-alternate-action). In the event of power failure, when power is restored, all relays will be in the OPEN position, and the TTL outputs will be low.

IN CASE OF PROBLEMS If problems should be encountered, first check to be sure power is properly connected to the modules. Also verify that the fiber is good. Then, check the transmitter status indicators. If lit, data is present. Check the Level/Loss indicators on the receivers. If they are green, the fiber optic cable connection is functional.

If any problems arise, please contact the GE Security customer service department and have the following information available: exact model number, product code, and serial numbers of your fiber optic links, and a listing of the diagnostic indicators and their respective color/condition.

Page 3 of the GE Digital Answering Machine (250D) user manual — 250D and 2250D
Page 3 · click to enlarge
Page 3

250D and 2250D

GE Digital Answering Machine (250D) — 250D and 2250D diagram (page 3)
Fig. 3 · 250D and 2250D
Page 4 of the GE Digital Answering Machine (250D) user manual — U.S. T (561) 998-6100 T 888-GE-SECURITY
Page 4 · click to enlarge
Page 4

250D and 2250D

Customer Support For assistance in installing, operating, maintaining, and troubleshooting this product, refer to this document and any other documentation provided. If you still have questions, please contact technical support during normal business hours (Monday through Friday, excluding holidays, between 6 a.m. and 5 p.m. Pacific Time).

GE Security Call: 888 437-3287 (US, including Alaska and Hawaii; Puerto Rico; Canada) Outside the toll-free area: 503 885-5700 Fax: 561 998-6224 www.gesecurity.com

U.S. T (561) 998-6100 T 888-GE-SECURITY

Asia T 852-2907-8108 F 852-2142-5063

Canada T 519-376-2430 F 519-376-7258

Latin America T 305-593-4301 F 305-593-4300

888 (437-3287) F 561 998-6224 E gesecuritycustserv@ge.com

Australia T 613-9239-1200 F 613-9239-1299

Europe T 44-113-238-1668 F 44-113-253-8121

www.GESecurity.com

As a company of innovation, GE Security reserves the right to change product specifications without notice. For the latest product specifications visit GE Security online at www.GESecurity.com or contact your GE Sales Representative.

Copyright © 2007 General Electric Company. All rights reserved.

11-0250-251099-A Released MAY-07

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the GE Digital Answering Machine (250D)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE Digital Answering Machine (250D)

Be the first to ask — other owners or our team will answer.

Original document

GE Digital Answering Machine (250D) manual PDF

4 pages·248 KB·Network Hardware·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…