Cool Only: AJCH 08, 10 ACB AJCH 10, 12 DCB AJCQ 08, 10 ACB AJCQ 10, 12 DCB AJCS 06 LCB AJCS 08, 10 ACB AJCS 09, 10, 12 DCB
Room
Heat/Cool: AJEH 12 DCB AJES 06 LSB AJES 08 ASB AJES 09, 10, 12 DCB AJES 10 DSB
Write the model and serial numbers here:
Serial # ____________________________
Find these numbers on a label on the front of the base pan behind the front grille.


Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
USE OF EXTENSION CORDS— 115-Volt models only
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.
However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.
When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.
However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.
If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.
The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.
Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.



Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
For Normal Cooling—Select the COOL mode and HIGH or MED fan with a middle set temperature.
For Maximum Cooling—Select the COOL mode and HIGH fan with a lower set temperature.
For Quieter & Nighttime Cooling—Select the COOL mode and LOW fan with a middle set temperature.
A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will
The fan switch is located behind the front grille on the control box.
When set at CONT (continuous, up) the fan runs all the time providing a more balanced temperature. The unit is shipped in the CONT setting.
When set at CYCLE (down) the fan cycles on and off.
Use the FAN mode to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a temperature setting will not be displayed.
Press FAN pad. Press LOW, MED or HI pads to set desired fan speed.
Press the MODE pad until the FAN indicator light is lit and the LOW, MED or HI indicator light is lit for the desired fan speed.
The vent control is located behind the front grille on the right side of the air discharge area. When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.
The unit leaves the factory set at the CLOSE position.
To open or close the vent: 1. Remove the front grille. 2. Remove the vent card screw. 3. Remove vent card, turn it over and replace it by locating rear hole in card over locating pin inside air discharge and reattaching screw at front.
OPEN position (Mesh end toward back)
CLOSE position (Mesh end toward front)
Horizontal louvers on the front grille let you control the air direction up and down.
Remove the front grille to adjust the vertical louvers side-to-side to direct the air left or right.

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
About the controls on the air conditioner—models with control knobs.
FAN HIGH
OFF
FAN
E
R
M
O
R
O
LOW COOL LOW HEAT
W
E
R
HIGH HEAT
HIGH COOL
OFF
LOW
LOW COOL
O
FAN
O
HIGH
HIGH COOL
E
R
FAN
MODE CONTROL TEMP CONTROL
Controls
Mode Control HIGH COOL and LOW COOL provide cooling with different fan speeds.
Temp Control The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to COOLER (blue) the indoor air will become cooler. Turn the knob to WARMER (red) and the indoor air will become warmer.
HIGH HEAT and LOW HEAT provide heating with different fan speeds.
LOW FAN or HIGH FAN provides air circulation and filtering without cooling or heating.
When the outdoor temperature is lower than 25°F., heat is provided by the electric heater in the air conditioner instead of by the heat pump.
For Normal Cooling or Heating—Select HIGH COOL or HIGH HEAT with the thermostat at mid point.
For Maximum Cooling—Select HIGH COOL with the thermostat at maximum cool.
For Maximum Heating—Select HIGH HEAT with the thermostat at maximum heat.
For Quieter & Nighttime Cooling—Select LOW COOL with the thermostat at mid point.

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
On Heat/Cool models, the fan switch lever is located in a hole through the control panel. To reach it, you need to remove the front grille. Use a small screwdriver to change the setting. Cool only models have a rocker switch on the front of the control box.
When set at CYCLE (down) the fan cycles on and off when cooling or heating. When set at CONT (continuous, up) the fan runs all the time, providing a more balanced temperature. The unit is shipped in the CONT setting.
Limiting the maximum and minimum settings prevents users from turning the control to the extreme heat or cool positions.
The normal range of the temp control is approximately 60°F to 85°F. The control range may be narrowed by the use of the temperature limiting screws located behind the control panel.
Each position equals approximately 3°F.
The vent control is located behind the front grille on the right side of the air discharge area. When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.
The unit leaves the factory set at the CLOSE position.
To open or close the vent: 1.Remove the front grille. 2.Remove the vent card screw. 3.Remove vent card, turn it over and replace it by locating rear hole in card over locating pin inside air discharge and reattaching screw at front.
OPEN position (Mesh end toward back)
CLOSE position (Mesh end toward front)
Horizontal louvers on the front grille let you control the air direction up and down.
Remove the front grille to adjust the vertical louvers side-to-side to direct the air left or right.

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
The front grille can be removed for more thorough cleaning or to make the model and serial numbers accessible.
To remove:
To replace:
Hook the tabs on the front grille even with the tabs on the case and snap into place.
Replace the screws and filter.

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
To maintain optimum performance, clean the filter at least every 30 days.
To remove the air filter, on other models:
Pull it down.
Dirty filter—Needs cleaning Clogged filter—Greatly reduces cooling, heating and airflow.
Turn the air conditioner off before cleaning.
The most important thing you can do to maintain the air conditioner is to clean the filter at least every 30 days. A clogged filter reduces cooling, heating and air flow.
To replace the air filter:
Replace the clean filter by pushing it back into place.
Keeping the air filter clean will:
I Decrease cost of operation.
I Save energy.
I Prevent clogged heat exchanger coils.
I Reduce the risk of premature component
failure.
To clean the air filters:
I Vacuum off the heavy soil.
I Run water through the filters.
I Dry thoroughly before replacing.
To remove the air filter, on some models:
Carefully pull the tab forward, up and out.
Operating without the filter in place or with a damaged filter will allow dirt and dust to reach the indoor coil and reduce the cooling, heating, airflow and efficiency of the unit.
Replacement filters are available from your salesperson, GE dealer, GE Service and Parts Center or authorized Customer Care® servicers.
Remove the battery cover by sliding it according to the arrow direction.
I Use 2 AAA (1.5 volt) batteries. Do not use
Insert new batteries making sure that the (+) and (–) of battery are installed correctly.
rechargeable batteries.
I Remove the batteries from the remote control
if the system is not going to be used for a long time. 3
Reattach the cover by sliding it back into position.

BEFORE YOU BEGIN
CAUTION:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Read these instructions completely and carefully.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems—consult a qualified electrician.
GE strongly recommends the removal of the old wall case and the installation of a new GE Wall Case. If you decide to keep the existing wall case, you may need a kit to ensure proper performance. If you DO NOT use a kit, you run the risk of poor performance or product failure. This is not covered under the terms of the GE warranty.
J-model air conditioners may fit in existing wall cases. However, they often need a kit to properly adapt the case to the GE air conditioner. Answer these questions and see the chart on the next page for the proper kit.
What brand air conditioner will you be replacing?
Some models require a 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker. The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
What are the dimensions of the wall case currently in use?
What is the model number of the chassis currently in use? What is the model (or Type) number of the wall case currently in use?
Frequently, the J-model adapter kit will apply to another brand model “series” or specific vintage. In these cases, you need the chassis model number and/or the wall case or “type” number to confirm the use of the correct adapter kit.
Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
What type of outdoor grille is used with the current wall case?
There may be an architectural grille attached to a wall case to enhance the exterior appearance of the building. Custom grilles may be used with J-model wall cases provided a J-model adapter kit is also used to ensure proper airflow.

Read these instructions completely and carefully.

USE GE KIT NUMBER: FOR: DESCRIPTION: RAK56A100 GE RAB13, 14 & 15 Fits all GE wall cases 26″W x 18″H x 24″D (ACLB & RCL Chassis) RAK1072 Hotpoint ACXB10 & 11 Adapts an older Hotpoint wall case to a “J” (ACTB Chassis) model chassis. Fits Hotpoint wall cases 253⁄4″W x 167⁄8″H x 185⁄8″D RAK1082 Whirlpool Type 23W Adapts Whirlpool wall case to a “J” Wall Case model chassis. Fits Whirlpool wall cases 257⁄8″W x 161⁄2″H x 231⁄8″D RAK1102 GE RAB30 Adapts GE wall case to a “J” model chassis. (“F” models) Fits the RAB 30 wall case 26″W x 18″H x 24″D RAK123A64 Fedders Wall Case “A” Adapts Fedders wall case to a “J” model chassis.
Fits Fedders wall cases 27″W x 163⁄4″H x 163⁄4″D RAK126 Westinghouse Wall Case Adapts Westinghouse wall case to a “J” (Type 2626D73H01) model chassis. Fits Westinghouse wall cases 257⁄8″W x 157⁄16″H x 16″D RAB46, 47 & 48 Use these kits for all Standard wall case for “J” model chassis. other brands not listed. RAG13 stamped aluminum exterior grille included. Remove the existing case and replace. RAK690 RAB36, 37, 38, 46, 47 or 48 If you attach a custom architectural outdoor (J-Chassis) grille, use this kit to ensure proper airflow. RAG13 RAB36, 37, 38, 46, 47 or 48 Standard aluminum exterior grille (included with RAB46, 47, and 48 wall (J-Chassis) cases) RAG14E RAB36, 37, 38, 46, 47 or 48 Architectural louvered exterior grille (J-Chassis)


REMOVE LOCKING PLATE ON FRONT LEFT SIDE 1 REINSTALL LOCKING PLATE WITH TAB BEHIND WALL CASE FLANGE. TIGHTEN SCREW
WHEN WALL OUTLET IS TO LEFT, EXTEND CORD UNDER UNIT AND HOLD IT IN PLACE WITH CLAMP
CAREFULLY SLIDE AIR CONDITIONER BACK INTO CASE Make sure that the tubing on the unit does not touch the wall case and that the case installation is secure.
ATTACH FRONT GRILLE An opening for the power cord is on the bottom of the front grille.

Read these instructions completely and carefully.
PREPARE OPENING IN WALL Make certain a wall receptacle is available close to the hole location or make arrangements to install a receptacle. The cord length for the 115-volt models is 72″ to the right and 47″ to the left. For the 230/208-volt models the cord length is 65″ to the right and 39″ to the left.
SUPPORT REQUIREMENTS FOR AIR CONDITIONER Mortar between the case and the brick all around the case may be undercut at about 45° for improved caulking.
SUPPORT REQUIREMENTS FOR AIR CONDITIONER The air conditioner wall case may be installed with 1/4″ min. extension out from the inside wall or with 1/4″ min. extension out from the outside wall. The finished sides of the opening should be structural wall members. Lintel – Use a lintel in brick veneer and brick and block types of wall to support the bricks or blocks above the opening. Do not allow the wall case to be used in lieu of a lintel. Flashing – Install flashing (drip rail) as shown to prevent water from dripping inside the wall and down the outside of the building.
Lintel angle (if required)
(on all 4 sides on the
Trim molding (if desired)
Caulking (above & below the flashing)
1/4″ min. extension inside the wall from


261⁄4″ min. (Without filler panels)

STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.
WOOD PIECES: WIDTH: 2″ LENGTH: Long enough to fit inside the window frame. THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2″ higher than the top of the storm window frame. Attach securely with nails or screws provided by the installer.
1/2″ higher than frame
Remove the three shipping pads inside the air conditioner next to the compressor.
Remove the front grille. See the Care and Cleaning section. Find the locking plate located on the front left side.
Remove the screw and the locking plate to unlock the air conditioner.
Remove the rear grille that is taped to the back of the case. Remove the packet of screws taped to the back of the grille. While holding the grille at a 45° angle, insert it into the clips at the top of the case and push the bottom in. Keep slight upward pressure on the grille until it fits flush with the bottom of the case.
Remove and discard the shipping screw on the back of the air conditioner to allow removal of the air conditioner from the case.
If attaching the grille from the outside of the case use the 2 long screws.
If attaching the grille on the inside of the case use the 2 short screws.
Pull the bottom corners of the air conditioner and slide it out of the case.
Insert the 2 long screws on
Insert the 2 short screws

Measure 123⁄8″ from the centerline on both sides for the sill support brackets.
Mark the centerline of the stool. Measure from the centerline 133⁄8″ on both sides for the panel cuts.
133⁄8″
123⁄8″
Turn the bolts and tighten the lock nuts to make the sill supports level or tilt down 1/8″ to the outside. Line up the “V” notch with 123⁄8″ marks. Drill pilot holes and attach the sill supports.
Assemble the sill supports. Do not fully tighten the spacer mounting screws at this time.
Before attaching the sill supports, place them on the window stool. Select the spacer position that will place the spacer near the outermost point on the sill. Tighten the spacer mounting screws.

Measure from the edge of the panel marks (see Prepare the Window) to the inside of the window track on each side. (A and B)
Type C (painted screws)
133⁄8″ 133⁄8″
Width of the air
conditioner (panel marks) Left side
Install the panels in the window. Place the spring clips 3″ from the top and the bottom. Squeeze and push the clips to fit in the window track and the tab into the sill support.
Mark the A and B measurements on each side of the filler panel board. Cut the panels and discard the center piece. Note position of the notches.
(holes are on the right)
(holes are on the left)
Hook the tab into the sill support
Put together the panel assemblies. Remove the paper backing from the case side gasket and attach it to the angle. Push a pencil point through the gaskets to locate the holes in the angles.

With the window closed, mark where the window sash meets the case.
Peel off the backing from the bottom window gasket.
Peel off the backing from the case top gasket.
Place the gasket on the stool and over the brackets, even with the rear edge, sticky side down.
Hold on to the case, open the window, and place the gasket along the mark on the case.
Put the gasket on top of the case where the window will close.
Carefully slide the empty case into the window until the holes in the case line up with the holes in the panel angles.
Place the vinyl window gasket over the case top gasket. Insert the panel tabs through the slits in the gasket. Cut the gasket on each side to the width of the window.
Lower the window so it fits behind the panel tabs. Insert the 4 type A screws through the holes in the case and into the panel angles, 2 on each side.
Close the window tightly on the vinyl gasket. Bend the gasket forward to expose the panel tabs. Drill pilot holes into the window sash.
Attach the panel tab to the window on each side with a type D screw.


Cut the foam top window gasket to the window width.
Attach the window locking bracket with 1 type E screw.
Stuff the foam between the glass and the window to prevent air and insects from getting into the room.
When the wall outlet is to the left, extend the cord under the unit and hold it in place with the clamp.
Carefully slide the air conditioner back into the case.
Reinstall the locking plate with the tab behind the wall case flange. Tighten the screw.
Attach the power cord to the base pan with the clamp.
Reattach the front grille. An opening for the power cord is on the bottom of the front grille.
Fill holes and cracks with caulking provided by the installer.

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
Troubleshooting Tips: Save time and money! Review the chart below first and you may not need to call for service.
Air conditioner The air conditioner • Make sure the air conditioner plug is pushed does not start is unplugged. completely into the outlet.
The fuse is blown/circuit • Check the house fuse/circuit breaker box and breaker is tripped. replace the fuse or reset the breaker.
Power failure. • If power failure occurs, turn the air conditioner OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.
Air conditioner does Airflow is restricted. • Make sure there are no curtains, blinds or furniture not cool as it should blocking the front of the air conditioner.
The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section.
The room may have been hot. • When the air conditioner is first turned on, you need to allow time for the room to cool down.
Cooling coils have iced up. • See “Air conditioner freezing up” below.
The remote control is The batteries are inserted • Check the position of the batteries. They should be not working incorrectly. inserted correctly.
The batteries may be dead. • Replace the batteries.
Water drips outside Hot, humid weather. • This is normal.
Water drips indoors The air conditioner is not • For proper water disposal, make sure the air tilted to the outside. conditioner slants slightly from the case front to the rear.
Water collects in Moisture removed from air • This is normal for a short period in areas with little base pan and drains into base pan. humidity; normal for a longer period in very humid areas.
I You may hear a pinging noise caused by
I Water will collect in the base pan during
water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
I The fan may run even when the compressor
I You may hear the thermostat click when the
does not.
compressor cycles on and off.

Air Conditioner Warranty.
Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, on-line, 24 hours a day, visit us at www.GEAppliances.com or call 800.GE.CARES (800.432.2737). For service in Canada, call 1.800.361.3400.
Staple your receipt here. Proof of the original purchase date is needed to obtain service
under the warranty.
One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this full one-year warranty, GE will also provide, free of charge, all labor original purchase and in-home service to replace the defective part.
Five Years Any part of the sealed refrigerating system (the compressor, condenser, evaporator From the date of the and all connecting tubing) which fails due to a defect in materials or workmanship. original purchase During this addtional four-year limited warranty, GE will also provide, free of charge, all labor and in-home service to replace the defective part.
IService trips to your home to teach you how to use the
IReplacement of house fuses or resetting of circuit
product.
breakers.
IImproper installation, delivery or maintenance. If you
IFailure due to corrosion on models not corrosion-
have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
protected.
IDamage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.
IIncidental or consequential damage caused by possible
IFailure of the product resulting from modifications to
defects with this air conditioner.
the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
IDamage caused after delivery.
IIn commercial locations labor necessary to move the
unit to a location where it is accessible for service by an individual technician.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA and Canada. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.