D Gebrauchsanweisung Duo-Pumpe GB Operating Instructions Dual Pump F Mode d’emploi Pompe universelle NL Gebruiksaanwijzing Duopomp S Bruksanvisning Universalpump I Istruzioni per l’uso Pompa Duo E Manual de instrucciones Bomba dúo P Instruções de utilização Bomba dupla DK Brugsanvisning Universalpumpe

®

Liquids to be pumped
Welcome to the Garden of GARDENA ...
According to DIN VDE (German Electrical Engineers’ Associa- tion) 0100, submersible pumps may only be used in swimming pools, garden ponds, and fountains if the pump is operated via a residual-current device with a residual-current rating of ≤30 mA. The pump must not be operated when there are persons in the swimming pool or garden pond.
The GARDENA Dual Pump can be used for pumping rainwater, tap water or chlorinated swimming pool water. The pump is fully submersible (waterproof sealed) and can be immersed in the liquid down to a depth of 9 m.
The GARDENA Dual Pump has been designed for private use around house and garden.
1. Where to Use Your GARDENA Dual Pump 11 2. For Your Safety 11 3. Initial Operation 13 4. Operation 14 5. Maintenance 14 6. Trouble-Shooting 14 7. Storage 16 8. Accessories 16 9. Technical Data 17 10. Service 17
v Please keep these instructions in a safe place.
Please read these operating instructions carefully and observe the notes given. Use these operating instructions to familiarise yourself with the Dual Pump, its correct use and the notes on safety.
The GARDENA Dual Pump is not designed for continuous operation (e.g. industrial application, continuous circulat- ing operation). Corrosive, easily combustible, aggressive or explosive substances (e.g. gasoline, petroleum or nitro thinner), salt water as well as food must not be pumped. The temperature of the liquid should not exceed 35 °C.
For safety reasons, children under the age of 16 as well as persons not familiar with these operating instructions should not use this Dual Pump.

Liquid fails to flow
Sand and other abrasive substances in the liquid cause in- creased wear and reduce the pump’s output. v Use a Pump Preliminary Filter if the water contains sand (Art. No. 1730 / 1731). The pump should not run against the closed delivery side for more than 5 minutes. v If liquid fails to flow, switch off the pump immediately.
When setting up the pump for use out of water In order to avoid dry-running of the pump, take care that the end of the suction hose is always submerged into the liquid. v Before each operation, fill the pump to overflowing with approx. 2 l of the liquid to be pumped!
v Clear the outlet line before use.
v Before operating the pump, first make a visual check, if there is any damage of the pump (esp. regarding power cable and plug). v Observe the minimum water level and the max. delivery height (see 9. Technical Data). A damaged pump must not be used. v In case of damage, please have the pump checked by our GARDENA Service Centre.
According to DIN VDE (German Electrical Engineers’ Associa- tion) 0620, mains power cables must not have a smaller cross- section than the rubber-sheathed cables of the designation H07 RNF. The cable length must be at least 10 m. Data indicated on the type plate must match technical data of the mains supply. v Take care that the electrical connections are made within dry area, protected from flooding. Protect plug and power cable from heat, oil and sharp edges. v Don’t use the power cable for plugging off. The power cable must not be used for mounting or relocating the pump. For submerging or lifting/securing the pump, fix a rope (available from GARDENA Service) to the pump’s carrying handle. Extension cables must meet the requirements of DIN VDE 0620.
In Switzerland mobile appliances which are used outdoors, must be connected via a residual-current device.
In Austria, according to ÖVE B/EN 60 555 part 1 to 3, pumps which are used in swimming pools and garden ponds, and equipped with firm power cable should be fed via an ÖVE approved isolating transformer – rated voltage must not exceed 230 V.
For safety reasons we recommend that you always operate the Dual Pump via a residual-current device (DIN VDE 0100-702 and 0100-738). v Please contact your electrician.

Connection hose to delivery side:
Connecting a filter or hose to the inlet side:
Hot water – risk of scalding
V Before each operation, fill the pump to overflowing A with approx. 2 l of the liquid to be pumped !
Only when setting up the pump for use out of water:
Best results regarding the delivery capacity of the pump are achieved when connecting 19 mm (3/4”) hoses in conjunction with e.g. • GARDENA Pump Connection Set, art. no. 1752, or when using 25 mm (1”) hoses with fittings available from your sanitary dealer. v Connect the pressure hose 5 to the connector 4 on the delivery side.
Both pump connectors 4 are equipped with a 33.3 mm (G 1”) thread to which 13 mm (1/2”), 19 mm (3/4”) and 16 mm (5/8”) hoses can be connected by using GARDENA hose connection system fittings.
Don’t use any hose connection system fittings on the suction side! A vacuum-resistant suction hose must be used
1. When setting up the pump for use underwater, screw the filter 1 onto the connection 2 at the inlet side of the pump. – or – When setting up the pump for use out of water, connect a vacuum-resistant suction hose 3 with filter to the connec- tion 2 at the inlet side of the pump and screw on so that the connection is air-tight. 2. When setting up the pump for use out of water with suction heights over 4 m, the suction hose should also be secured (fas- tened to a wooden peg for example). The pump is relieved of the weight of the suction hose.
If the pump is operated for prolonged periods of time (> 5 min) with the delivery side closed, the water in the pump may heat up so that there is a risk of scalding yourself with hot water. v The pump should not run against the closed delivery side for more than 5 minutes. v If liquid fails to flow, switch off the pump immediately.
The minimum flow rate is 80 l/h (= 1.3 l/min). Watering accessories with lower rate must not be operated.

Freeing the impeller:
5. Maintenance
Pumping liquid:
Starting the pump:
5 1m
If the impeller blocks or clogs you can remove the dirt to free the impeller. 1. Unscrew the screw plug 8 using a screwdriver. 2. You can now turn the impeller shaft 9 in the casing using a screwdriver. This will free the blocked or clogged impeller. 3. Replace the screw plug 8 using a screwdriver.
The GARDENA Dual Pump is virtually maintenance-free.
When using the pump for pressure intensification, the max. per- missible internal pressure of 6 bar (on the delivery side) must not be exceeded. The to be increased delivery pressure and the pump pressure sum up.
v If the pump has still not started pumping after 7 minutes, unplug the mains plug (see 6. Trouble Shooting).
1. Fill the pump to overflowing with approx. 2 l of the liquid to be pumped (see “3. Initial Operation”, “Filling the pump” ). 2. Open all possible shut-off devices in the pressure line (watering accessories, Water Stop, etc.). 3. Drain remaining water in pressure hose so that air can escape during the suction process. 4. Plug the mains plug of the pump into a 230 V / 50 Hz alternat- ing current socket. The pump starts. 5. Hold the hose 5 at the delivery side approx. 1 m vertically above the pump until the pump begins to pump.
When setting up the pump for use out of water
When setting up the pump for use in water: v Plug the mains plug of the pump into a 230 V / 50 Hz alternat- ing current socket. The pump starts.
The specified maximum Pump is not filled and suction 1. Fill the pump using the filler self-priming height is not hose is not held upwards. neck until it overflows.
Pump runs when out of water You didn’t fill the pump with v Fill in liquid (see point but does not start pumping any liquid before operation. “3. Initial Operation”). when in water The liquid escapes over 1. Fill up the pump again (see the hose which is connected point 3. Initial Operation). to the delivery side during 2. When starting operation the suction action. hold the pressure hose approx. 1 m vertically above the pump, until the suction action has taken place.
Pump runs, but the suction Air cannot escape, since v Open all possible shut-off action doesn’t take place. delivery side is closed devices (e.g. spray nozzle) or remaining water is in the in the pressure line, or drain pressure hose. the pressure hose or dis- connect it during the suction action.
Problem Probable cause Remedy
In case of any other difficulties concerning the suction action, use GARDENA Suction Hoses with Backflow Preventer (see point “8. Accessories”) and fill in the liquid to be pumped over the filler cap 7 before operation.
Too high suction height. v Reduce suction height.
Suction filter or backflow v Clean the filter or the back- preventer in the suction hose flow preventer. clogged.
The waiting time wasn’t v Switch on the pump and observed. wait max. 7 min.
Air cannot escape, since v Open all possible shut-off delivery side is closed devices (e.g. spray nozzle) or remaining water is in the in the pressure line, or drain pressure hose. the pressure hose or dis- connect it during the suction action.
Leaky screw fitting at the filler v Tighten the screw fitting cap 7. (do not use pliers).
Leaky or damaged suction v Seal the connections or hose. check suction hose for damages.
Absolutely vacuum-resistant connection is achieved by using GARDENA Suction Hoses (see point “8. Accessories”).

GARDENA Prevents the pump from dama- Dry-Running Safety ges in case of missing liquid. • Art. no. 1741
GARDENA Electronic Automatically cuts in and out Manometric Switch the pump depending on the current operating pressure. With dry-running safety. • Art. no. 1739
GARDENA Recommended for pumping Pump Preliminary Filter sandy liquids. • Art. no. 1730 / 1731
GARDENA Suction Filter To equip suction hoses with Backflow Preventer sold by the metre. • Art. no. 1726 / 1727 / 1728
GARDENA Suction Hose Fittings • Art. no. 1723 / 1724
GARDENA Suction Hoses Kink- and vacuum-resistant, sold by the metre with 19 mm (3/4”) or 25 mm (1”) diameter without fittings or in fixed length, complete with fittings.
Wintering / Storage:
If you have any problems with your pump, please contact our Service.
Pump motor doesn’t start No power. v Check fuses and electric or suddenly stops. connections.
Pump motor runs, but Suction filter at the suction v Reduce flow rate on the delivery capacity or pres- hose is sucked free. delivery side with a regula- sure suddenly decreases. tor valve, e.g. GARDENA art. no. (2)977.
Problem Probable cause Remedy
Empty your Dual Pump before the first frost sets in.
Electric failure. v Send the pump to one of our GARDENA Service Centres.
Impeller clogged. v Send the pump to one of our GARDENA Service Centres.
Thermal overload switch v Free the impeller and open has cut out the pump due the pressure side. to overheating/overloading.
Impeller blocked. v Free the impeller.
Suction filter or backflow v Clean filter or back-flow preventer clogged. preventer.
Noise level L WA1) 66 dB (A)
Weight 7.8 kg
Voltage 230 V AC
Perm. internal pressure (delivery side) 6 bar
Max. self-priming suction height 8 m
Max. delivery head 33 m
Max. pressure 3.3 bar
Max. delivery capacity 5,200 l/h
Rated power 750 W
5000/3 SGP (Art. 1471)
0 0 1000 2000 3000 4000 5000 6000 l/h

Description of the unit: Dual Pump Type: 5000/3 SGP Art. No.: 1471 EU directives: Machinery Directive 98/37/EC Electromagnetic Compatibility 89/336/EC Low Voltage Directive 73/23/EC Directive 93/68/EC Directive 2000/14/EC Harmonised European standards: EN 292-1 EN 292-2 EN 60335-1 EN 60335-2-41 Noise level: measured 66 dB (A) guaranteed 69 dB (A) Year of CE marking: 2002
The undersigned GARDENA Kress + Kastner GmbH · Hans-Lorenser-Str. 40 · D-89079 Ulm hereby certifies that, when leaving our factory, the unit indicated below is in accordance with the harmonised EU guidelines, EU standards of safety and product specific standards. This certificate becomes void if the unit is modified without our approval.
Ulm, 09.07.2002 Thomas Heinl Technical Dept. Manager
We expressly point out that, in accordance with the product liability law, we are not liable for any damage caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts or parts approved by us, and, if the repairs were not carried out by a GARDENA Service Centre or an authorised specialist. The same applies to spare parts and accessories.
If a fault occurs with your Dual Pump, please return the faulty unit together with a copy of the receipt and a description of the fault, with postage paid to one of the GARDENA Service Centres listed on the back of these operating instructions.
Product Liability

Deutschland GARDENA Kress + Kastner GmbH GARDENA Service Hans-Lorenser-Straße 40 D-89079 Ulm Produktfragen: (07 31) 490-123 Reparaturen: (07 31) 490-290 Argentina Argensem S.A. Venezuela 1075 (1618) El Talar - Buenos Aires Australia NYLEX Consumer Division 76-88 Mills Road P.O. Box 722 Braeside 3195 Melbourne, Victoria Austria GARDENA Österreich Ges. m.b.H. Stettnerweg 11-15 2100 Korneuburg Belgium MARKT (Belgium) NV/SA Sterrebeekstraat 163 1930 Zaventem Brazil M. Cassab Av. das Nações Unidas, 20.882 Santo Amaro, CEP 04795-000 São Paulo - S.P. Bulgaria / България ДЕНЕКС ООД Бул. ”Г.М.Димитров” 16 ет.4 София 1797 Canada GARDENA Canada Ltd. 100, Summerlea Road Brampton, Ontario Canada L6T 4X3 Chile Antonio Martinic Y CIA. LTDA. Gilberto Fuenzalida 185 Loc. Las Condes - Santiago de Chile Costa Rica Compania Exim Euroiberoamericana S.A. 350 Sur del Automercado Los Yoses San Pedro Cyprus FARMOKIPIKI LTD P.O. Box 7098 74, Digeni Akrita Ave. 1641 Nicosia Czech Republic GARDENA spol. s.r.o. Шнpskб 20a, и.p. 1153 62700 Brno Denmark GARDENA Danmark A/S Naverland 8 2600 Glostrup
Finland Habitec Oy Martinkyläntie 52 01720 Vantaa France GARDENA France Service Après-Vente BP 50080 95948 ROISSY CDG Cedex Great Britain GARDENA UK Ltd. 27-28 Brenkley Way Blezard Business Park Seaton Burn Newcastle upon Tyne NE13 6DS Greece Agrokip G. Psomadopoulos & Co. 33a, Ifestou str. Koropi 194 00 Athens Hungary GARDENA Magyarország Kft. Késmárk utca 22 1158 Budapest Iceland Heimilistaeki hf Saetun 8 P.O. Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin & Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S.r.l. Via Donizetti 22 20020 Lainate (Mi) Japan KAKUDAI Mfg. Co. Ltd. 1-4-4, Itachibori Nishi-ku Osaka 550 Luxembourg Magasins Jules Neuberg Grand Rue 30 Case Postale No. 12 Luxembourg 2010 Netherlands GARDENA Nederland B.V. Postbus 50176 1305 AD ALMERE Neth. Antilles Jonka Enterprises N.V. Sta. Rosa Weg 196 P.O. Box 8200 Curaçao New Zealand NYLEX New Zealand Limited Private Bag 94001 South Auckland Mail Centre 10 Offenhauser Drive East Tamaki, Manukau
1471-20.960.02/0021 © GARDENA Kress + Kastner GmbH Postfach 27 47, D-89070 Ulm http://www.gardena.com
Norway GARDENA Norge A/S Postboks 214 2013 Skjetten Poland GARDENA Polska Sp. z o.o. Szymanów 9 d 05-532 Baniocha Portugal MARKT (Portugal), Lda. Recta da Granja do Marquês Edif. GARDENA Algueirão 2725-596 Mem Martins Russia / Россия АО АМИДА ТТЦ ул. Моcфилмовcкая 66 117330 Моcква Singapore Variware Holland Road Shopping Centre 227-A 1st Fl., Unit 29 Holland Avenue Singapore 1027 Slowenia / Croatia Silk d.o.o. Trgovina Brodišče 15 1236 Trzin South Africa GARDENA South Africa (Pty.) Ltd. P.O. Box 11534 Vorna Valley 1686 Spain ANMI Andreu y Miriam S.A. Calle Pere IV, 111 08018 Barcelona Sweden GARDENA Svenska AB Box 9003 20039 Malmö Switzerland GARDENA Kress + Kastner AG Bitziberg 1 8184 Bachenbülach Ukraine / Украина АОЗТ АЛЬЦЕСТ ул. Гайдара 50 г. Киев 01033 Turkey Dost Diþ Ticaret Mümessillik A.Þ. Yeþilbaðlar Mah. Baþkent Cad. No. 26 Pendik - Ýstanbul USA GARDENA 3085 Shawnee Drive Winchester, VA 22604