Instruction/ maintenance manual of the product AW 200-790 Gaggenau
Go to page of 20
Operating and Assembly Instructions AW 200-790 AW 201-790 Extractor Hood.
1 AW 200-790 AW 201-790 Preface Safety notes Page 3 1. Important notes Page 4-5 1.1 F or your safety Page 4 1.2 Operating for the first time Page 5 1.3 About use Page 5 2. F eatures Page 6 3. Operation Page 7-9 4. Cleaning and care Page 10-1 1 5. Maintenance Page 12 6.
2 Preface With your new extractor hood, working in the kitchen will be even more fun. The appliance offers you a number of advantages: – a good extraction capacity with low noise values, – a large number of control functions, – optimum illumination of the cooking surface by a dimmable halogen light.
W ARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJUR Y TO PERSONS, OBSER VE THE FOLLOWING: a.) Use this unit only in the manner intended by the manufacturer .
4 1.1 F or your safety – Damaged appliances must not be operated. – The appliance must only be connected by an authorised specialist , paying attention to the relevant regulations of the power supply companies and the regional construction regulations.
1.2 Operating for the first time Before operating the appliance for the first time, please pay attention to the following notes: – The appliance must be installed and connected by a specialist before it is operated for the first time.
6 2. F eatures 1 V entilation duct 2 Control panel 3 Grease filters 4 Lighting Installation accessories for exhaust air mode Stainless steel-design ventilation duct: LK 010-012 for ceiling heights of .
7 3. Operation After they have been pressed, all functions selection keys except 0 (“Motor off”) are backlit in green. Light The lighting can be switched on or off, regardless of whether the wall extractor is in operation, by pressing the key (see Fig.
8 The Int key for the intensive level should be pressed when browning and frying in an open pan (see Fig. 6). If you have switched on the hood by selecting the intensive level, it will be switched off again automatically after 5 minutes.
9 Special functions: Intensive time: Y ou can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the Int key and the 1, 2 or 3 key and you can store this setting (see Fig. 9). When delivered, the appliance is set to five minutes, i.
10 Cleaning the grease filters The grease filter saturation display F flashes after an operating time of 30 hours to you indicate to you that you should clean the grease filter (see Fig. 3). The grease filters can of course be cleaned at any time, even if the grease filter saturation display has not started to flash.
11 Cleaning the extractor hood Clean the exterior of your extractor hood with a soft cloth and mild detergent solution. Do not use any strong, caustic or abrasive cleaning agents. Do not use any abrasive sponges or brushes either . Clean the stainless-steel extractor hood (A W 200) with stainless steel cleaner .
The appliance must be disconnected from the power supply during all repair work. If the appliance does not function correctly , check the fuses first. If the power supply is functioning correctly , bu.
13 W ARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJUR Y TO PERSONS, OBSER VE THE FOLLOWING: a.) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
14 6.2 Installation The applicable regulations of the energy supply companies and the regional construction regulations must be observed when installing the hood. This hood has been approved for installations as low as 30 ´ ´ and as high as 36 ´ ´ above the cooktop.
15 Flexible aluminium pipes, corrosion-protected sheet metal pipes and exhaust air pipes whose material conforms to fire B1 in accordance with DIN 4102 can be used.
16 Proceed as follows: – From the bottom edge of the hood, mark a center line on the wall. – With the aid of the drilling template, mark the positions of the screws on the wall (Fig. 19). Note: this hood has been approved for installations as low as 30 ´ ´ and as high as 36 ´ ´ above the cooktop.
– Secure the hood on the wall with the four screws b (Fig. 21 and 22). F or exhaust air mode proceed as follows: – Establish the pipe connection. – Establish the electrical connection. – Stainless steel chimney only (LK 010-012/022): pull the protective film off the chimney’s trims.
F or circulating air mode use the installation set included with the ventilation ducts LK 010-1 12/122 und LK 01 1-1 12/122. Y ou also need an activated charcoal filter (KF 001-010). Proceed as follows: – Slightly loosen the screws of the retaining bracket for the chimney paneling.
EN 780 DEDHAM STREET CANTON, MA 02021 USA Y 800.828.9165 www.gaggenau-usa.com GAGGENAU HAUSGERÄTE GMBH CARL-WERY-STR. 34 · 81739 MÜNCHEN GERMANY Y (0 89) 45 90 - 03 FAX (0 89) 45 90 - 23 47.
An important point after buying a device Gaggenau AW 200-790 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Gaggenau AW 200-790 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Gaggenau AW 200-790 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Gaggenau AW 200-790 you will learn all the available features of the product, as well as information on its operation. The information that you get Gaggenau AW 200-790 will certainly help you make a decision on the purchase.
If you already are a holder of Gaggenau AW 200-790, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Gaggenau AW 200-790.
However, one of the most important roles played by the user manual is to help in solving problems with Gaggenau AW 200-790. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Gaggenau AW 200-790 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center