PE1004CF
CAT-5 RECEIVER CARD FOR
PIONEER PLASMA EXPANSION
USER’S GUIDE




1.5 FCC / CE NOTICE
Please read this manual carefully before using your PE1004CF. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your PE1004CF and to prevent fire and shock hazard. Please read them carefully and heed all warnings.
400-0210-001 2


The PE1004CF CAT-5 Receiver Card is designed to receive RGBHV/YPbPr video and audio signals over twisted pair (CAT-5) type cable. The encoded CAT-5 signals are Altinex Standard Audio+ Video signals from a compatible transmitter such as the Altinex DA1930CT. The PE1004CF installs directly into the plasma monitor and converts the signals into Pioneer compatible inputs. The PE1004CF has three twisted pair audio+video inputs and one RGBHV input with an accompanying stereo audio input. Additionally, the PE1004CF provides a buffered audio and video local output and a CAT-5 distribution output. Any one of the four inputs may be selected at a time. The PE1004CF is compatible with video resolutions VGA through UXGA. The unit offers hardware and software video equalization for transmission lengths up to 400 feet. The video equalization works in conjunction with the video equalization on the transmitter and the quality of CAT-5 cable. Audio transmitted over the CAT-5 cable is decoded and then output on the audio output jack, as well as distributed on the CAT-5 output. The audio output follows the selected video input line. The plasma monitor’s internal controls allow selection of the PE1004CF default inputs, or the PE1004CF input to the monitor may be controlled via standard RS-232 communication. Available commands allow input selection to any of the three expansion inputs. The HelpInside™feature allows programmers to have access to command structures and control of the PE1004CF from any terminal using the [HELP] command. In conjunction with Altinex’s unique command structure, HelpInside™ provides easier-than-ever control of the PE1004CF CAT-5 Receiver with simple keyboard commands. No typing of long keyboard strings is necessary.
Table 1. PE1004CF General

Table 2. PE1004CF Mechanical

Table 3. PE1004CF Electrical

400-0210-001 3


DIAGRAM 1: INPUT SELECTION
AUTOMATIC INPUT SELECTION Selecting plasma Input 3 displays PE1004CF CAT-5 #1 Input image on the plasma Input 3. Selecting plasma Input 4 displays PE1004CF CAT-5 #2 Input image on the plasma Input 4. Selecting plasma Input 5 displays PE1004CF CAT-5 #3 Input image on the plasma Input 5.
MANUAL INPUT SELECTION In order to force an input on the PE1004CF to a specific expansion input on the plasma monitor, it is necessary to select the desired plasma monitor input number first. Then, use the RS-232 ASCII command, [IN], to switch the PE1004CF to its desired input.


400-0210-001 4



400-0210-001 5



400-0210-001 6


EQUALIZATION Set SW2 to the HW position for hardware equalization.
Set SW2 to the SW position for software equalization.

400-0210-001 7

OPERATION 7
The PE1004CF has many advanced remote control capabilities which are accessible through standard RS-232 communication. Actual controlling may be achieved using a computer control system or other device capable of sending RS-232 commands.
The RS-232 commands, for the PE1004CF, are in a simple ASCII character format. 1. Square brackets “[ ]” are part of the command. 2. Use uppercase letters for all commands. After processing a command, an “OK” will be returned as feedback if the command is good. Commands ending in ‘S’ will be saved into memory. Commands not ending in ‘S’ will still be executed but will not be restored after the system is powered off. 7.2 DESCRIPTION OF COMMANDS
The default unit ID is zero, but may be set to a value from 0 to 99. In single unit operation, commands may be sent without the unit identifier. Unit ID 0 should be used for single unit operation. If multiple PE1004CFs are connected to the same communication port, the units may be controlled in two different ways: either individually, or more than one simultaneously. In order to control all the units the same way commands may be sent without the unit identifier. Commands sent without the unit identifier will be executed by all PE1004CFs. Example:
correspond to PE1004CF inputs CAT-5 #1, CAT-5 #2 and CAT-5 #3 respectively. Select input 3 on the plasma display and CAT-5 #1 on the PE1004CF will automatically be selected.
[VER]: Executed by all units. [VERC1]: For Unit ID 1 Only [VERC2]: For Unit ID 2 Only
Individual control is accomplished by first assigning each unit a unique ID number. Then each unit may be controlled individually by including the unit identifier at the end of each command string.
image quality.
400-0210-001 8
![Page 10 of the Altinex PE1004CF user manual — 5. [STATUS]](/cdn/reader/5f/5f34bd7b3d2e88906c2d3b3400206febcbc517921ed27a4870f90b17e9525549/images/page-10.webp?w=400)
Example:
This command sets the ID number of the unit. The default unit ID is zero. Command Format: [SIDn]
Send the command [VER] and receive the following feedback: PE1004CF 690-0207-001 PE1004CF = Model Number 690-0207-001 = Firmware Version
n = Unit ID (n = # from 0 to 99) Example:
Send the command [SID1] to the system. The unit ID is now one, and “C1” must be included at the end of each command line, as in “[VERC1]”, for only the unit with ID1 to respond. REMEMBER: A command sent without the unit
This command displays the status of the PE1004CF and includes the unit model number, active input and video equalization level. Command Format: [Ci]
ID will be executed by all the PE1004CFs connected to the RS-232 port. 2. [RSI]
Ci = Unit ID (i = # from 0 to 99)
Pioneer Video Card IN:1 (CAT-5 # 1) Equalization Level:0
This command resets the unit ID to the default value of zero. Command Format: [RSI]
Example:
Send the command [STATUSC1] and receive feedback showing the status of Unit ID 1. Example 3: Any Unit
Send the command [RSI] to the system and the new ID will be zero. As unit ID zero, commands may be sent either with or without the unit identifier “C0”. 3. [RSN]
Send the command [STATUS] and receive feedback showing the status of the unit connected to the RS-232 port regardless of its unit ID. 6. [FRESET]
This command reads and then displays the ID number of the unit. Command Format: [RSN]
This command is used to preform a factory reset on the unit. The default input, CAT-5 #1, will be selected and all equalization settings will be set to zero, even if they were previoulsy saved using the […S] command. Command Format: [FRESETCi]
Example:
The PE1004CF was set to an ID value of 3. Send the command [RSN] and the system will return the following feedback: PE1004 ID#3 4. [VER]
Ci = Unit ID (i = # from 0 to 99)
Example:
This command displays the firmware version and model number of the PE1004CF. Command Format: [VERCi]
Reset the PE1004CF with unit ID 1 to its default settings by sending the command [FRESETC1].
Ci = Unit ID (i = # from 0 to 99)
400-0210-001 9
![Page 11 of the Altinex PE1004CF user manual — 7. [IN]](/cdn/reader/5f/5f34bd7b3d2e88906c2d3b3400206febcbc517921ed27a4870f90b17e9525549/images/page-11.webp?w=400)
This command is used to select the PE1004CF input that will be directed to the plasma display’s active expansion input. Command Format: [INnCi]
This command increments a selected property, in this case equalization, to be adjusted using RS-232 control. Command Format: [ + ], [+k]
n = Input Number (n = 1, 2, 3 or 4)
[+] = Increment level by one-step [+k] = Increment level by 'k' steps Example:
Ci = Unit ID (i = # from 0 to 99)
Example:
Select the equalization command by sending the command [EQ]. The current level is 150, but it is not the optimal value. After sending the following commands, an optimum level of 160 is obtained: 1. [EQ] The current level is 10. 2. [+][+][+][+][+][+][+][+][+][+] or [ + 10 ] The level is now 160 and no further adjustments are required. 11. [ - ]
Output the PE1004C’s CAT-5 #2 input to the plasma display input number 3. First, set the plasma to expansion input three. Then send the command [IN2] to output the PE1004CF’s CAT-5 #2 input to the plasma monitor. REMEMBER: When an expansion input is
selected on the monitor, its corresponding PE1004CF input is selected automatically. 8. [EQn]
This command is used to set the amount of video equalization when software equalization is selected, and to make it active for adjustments using the [+] and [ - ] commands. Command Format: [EQnCi]
This command decrements a selected property, in this case equalization, to be adjusted using RS-232 control. Command Format: [ - ], [-k]
n = Equalization amount (n = # from 0 to 254)
[-] = Decrement level by one-step [-k] = Decrement level by 'k' steps Example:
Ci = Unit ID (i = # from 0 to 99)
Select the equalization command by sending the command [EQ]. The current level is 160, but it is not the optimal value. After sending the following commands, an optimum level of 140 is obtained: 1. [EQ] The current level is 160. 2. [ – ] [ – ] [ – ] … [ – ] or [– 20] The level is now 140 and is no further
This command displays the current level of software equalization and makes it active for adjustments using the [+] and [ - ] commands. Command Format: [EQCi]
Ci = Unit ID (i = # from 0 to 99)
Example: Check the video equalization level to by sending the command [EQ]. The system will return the following feedback for the previous example: 150
adjustments are required.
400-0210-001 10

TROUBLESHOOTING GUIDE 8
This command will save the configuration command being sent to the PE1004CF into its nonvolatile memory. Example: Equalization
We have carefully tested and have found no problems in the supplied PE1004CF. However, we would like to offer suggestions for the following:
If Input 4 is currently the active input, send the command [EQ100S] to save the equalization value of 100 for this input. After power up, the equalization for Input 4 will be set to 100. 13. [HELP]
Cause 1: The source has a problem. Solution: Check the source and make sure that there is a signal present and all source connections are correct. If the source is working and there is still no display, see Cause 2. Cause 2: The correct input is not selected. Solution: Select the input using the default jumper or RS-232 bus. (See RS-232 accessible commands in Section 7). If no display is present, see Cause 3. Cause 3: Cable connections are incorrect. Solution: Make sure that cables are properly connected. Also, make sure that the continuity and wiring are good. If there is still no display present, see Cause 4. Cause 4: The display has a problem. Solution: Make sure the display has power and is turned on. If there is still no display, please call Altinex at (714)-990-2300.
This command displays information available for the Multi-Tasker interface commands. Command Format: [HELPCi]
Ci = Unit ID (i = # from 0 to 99)
Example:
In order to display the RS-232 commands available for the PE1004CF, send the command [HELP]. The commands, along with a brief description, will be displayed in the terminal window.
Cause 1: The source has a problem. Solution: Check the source and make sure that it is working at an appropriate volume level and all source connections are correct. If the source is working and there is still no sound, see Cause 2. Cause 2: The wrong input is selected. Solution: Select the video input that corresponds to the audio input. If no sound is present, see Cause 3.
400-0210-001 11

Cause 3: Cable connections are incorrect. Solution: Make sure that the cables are connected properly. Also, make sure that the continuity and wiring are good. If there is still no sound present, see Cause 4. Cause 4: Destination amplifier has a problem. Solution 1: Make sure that the destination
9.1 LIMITED WARRANTY/RETURN POLICY
Please see the Altinex website at www.altinex.com for details on warranty and return policy. 9.2 CONTACT INFORMATION
ALTINEX, INC 592 Apollo Street Brea, CA 92821 USA TEL: 714 990-2300 TOLL FREE: 1-800-ALTINEX WEB: www.altinex.com E-MAIL: solutions@altinex.com
amplifier is powered. If there is still no sound, see Solution 2 Solution 2: Set the volume of the destination
amplifier to a reasonable level. If there is still no sound, call ALTINEX at (714) 990-2300.
400-0210-001 12
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.