Instruction/ maintenance manual of the product SC-50/110 Furuno
Go to page of 30
SA TELLITE COMP ASS SC-50/110.
The paper used in this manual is elemental chlorine free. FURUNO Authorized Distributor/Dealer FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, 9-52 Ashihara-cho, Nishinomi y a 662-8580, JAPAN .
Contents 1. Over view ...................................................................................... 1 2. Maintenanc e Menu ....................................................................... 2 1 ) MONITOR display .........................
.
1 1. Overview The satellite compass, SC-50/110 calcula tes the heading by using the carrier signal of the GPS satellite signals. The system also calculates the heading with three rate sensors. When the satellite signal is blocked, the system output s the heading data based on the rate sensor signal for a maximum of 5 minutes.
2 2. Maintenance Menu The system provides TEC menu or Maintenance m enu for servicing. To show TEC menu, press and hold down MENU and ENT keys simultaneously until the menu appears af ter three beeps. It takes about 8 seconds to hear the third beep. Release the finger from MENU key, and then ENT key.
3 Shows difference between GPS and rate sensor. Shows an error. 1: error, 0: no error 1 normally Factory use Factory use 2) COMPASS display MASK-EL is used to set a minimum elevation angle of the satellite. The satellite of which elevation angle is lower than MASK-EL is not used for heading calculation.
4 4) R-CALIB display R-CALIB (Rate sensor Calibration) is used to enter the calibration value of the rate sensor at factory. It is not necessary to change this value when the rate sensor is replaced with new one. However, the value on top of the original sens or is written on top of the replacement sensor for future service.
5 Number of consecutive errors (For example, an error message appears with three consecutive ROL errors.) 5) RATE ERR display This menu sets the level to trigger the heading error alarms; NO HEADING OUTPUT and RATE ERROR. The system compares the output of the angular rate sensor with one obtained by the GPS signal.
6 7) ALARM display This menu sets the ALARM port signal. When ALARM MODE is set to “STOP,” the alarm signal is not sent out after acknowledgeme nt. When selected “Continue,” the system continues to output the alarm signal. 8) ANALOG display This menu is used to test and compensate th e motion sensor output signal.
7 The display consists of four indications; a ci rcular graph which shows direction where the tracking error rate is the highest, a bar gr aph which shows tracking error rates in 12 directions, mutlipath indexes, and elapsed time. Circular graph: Shows the relation of 12 directions to the bow.
8 10) MESSAGE display Error messages appear in the display. If RATE E RROR! appears, first check Installation Setup menu for correct setting: “Mounting” method and “Direction.” Fig.14 Error Message display 11) REC MONI menu The REC MONI display, Figure 15 shows whether the system works normally or not.
9 3. Replacement of Battery The processor unit has a battery which back s up the RAM contents when the power is removed. When the voltage of the battery dr ops to 2.5 V, the message “BATTERY!” appears on the screen. To check the message, pre ss [MENU] key and choose “MESSAGE.
10 5. Program Upgrade The three programs are used for the SC-50/110. Two programs are used in the processor unit and one program is in the display unit. The program num bers are tabulated below. Note that the program number of SC-50 is the sam e as SC-110, but they are different.
11 2) CPU board (Display unit) To upgrade the program on the CPU board; 1. Connect the serial port of the PC to J15 on MAIN board in the processor unit. 2. Turn on the PC. Do not as yet turn on the SC-50/110. 3. Click the SCUP.bat file in the SC-50/110 program file.
12 6. Maintenance 6.1 Adjustment 1) PWR board Switching regulator frequency is adjusted on PWR board, 20P8181 as below. Test Point GND Rating Adjuster TP2 TP1 120.0 kHz ± 10 kHz VR79 TP5 TP3 120.0 kHz ± 10 kHz VR80 2) MAIN board Vcc-c supply voltage to Rate sensor is adjusted by VR96 on MAIN board, 20P8178.
13 7. Location of Parts Rate Sensor (Default: Pitch) GPS Receivers (1, 2, 3 from Top) Rate Sensor (Default: Roll) Rate Sensor (Default: Yaw) Main Board (20P8178) PWR Board (20P8181) Fi g .
14 Fi g .19 MAIN Board, 20P8178 BT1 (CR2450-F2ST2L) Roll (above) Pitch Log/Alarm Beacon Ext D a t a o u t 1 t o 5 D a t a I n ( from ri g ht, IEC or AD-10 Headin g data ) J15 for system update J20 J19.
15 J2 to J7 Appendix 1 Protection of ICs in Data Output Circuit Appendix 1 describes how to prevent ICs in the data output circuit temporarily. Refer to Appendix 2 for permanent remedy. Symptom U1, U2, and U3 in the heading output circuit are damaged.
16 1. Fabrication of Signal Cable The signal cable is fabricated as below. DO NOT hold back the cable shield over the armor. The installation manual will be revised. 80 80 40 70 70 40 Twist and cut . Armor FV1.25-M3 Solder Grounding wire Remove coat for clamping.
17 2. Grounding Cable Shield Ground the cable shield or gr ounding wire to the chassis by using the screw fixing the MAIN board, 20P8178 to the chassis.
18 3. Adding Zener Diodes Zener diodes are added to the data output circuit as below. 1. Fabricate the diode as shown in the figure below. T y p e : R D 9 . 1 E B 3 - T 4 C/N: 000-138-700 Fig. 4 Fabrication of zener diode 2. Remove the coat and solder the diode.
19 Reference) The following waveforms show the effe ctiveness of the modification. With the SC-50/110 processor unit being not m odified, a spike noise is observed at the output terminal on SC-50/110 when the interconnected unit is turned on. (Fig. 6) After modification, t he noise is not observed.
20 Appendix 2 Modification on Data Output Circuit Appendix 1 describes the tentative remedy to prevent U1, U2, and U3 in the heading output circuit from being damaged. Following modification (Table below) is the permanent remedy. The connector is changed from 4 pins to 5 pins for the connection of cable shield.
APPROVED CHECKED DRAWN DWG.NO. MODEL UNIT SC-501/1101 演算部 PROCESSOR UNIT SC-50/110 S. kubota T. Yoshida 0 6 S ep. 2005 0 6 S ep. 2005 0 6 S ep. 2005 H.
APPROVED CHECKED DRAWN DWG.NO. MODEL UNIT SC-303-T SC-50 S.kubota T.Yoshida 06 Sep.2005 06 Sep.2005 06 Sep.2005 H.Kuwamura GPS クウチユウセンブ RADOME ANTENNA UNIT C 7251-E02-A F U N O ト.
D C B A 6 5 4 3 2 1 演算部 表示部 DIS PLAY U NI T PROC ESSOR UN IT CABLE W/ YEL-LIN E 黄線入ケ ーブル 赤線入ケ ーブル CABLE W/ RED-LIN E ANTE NNA UNIT 空中線部 SC-60 3 ANT 1 AN.
S - 2.
S - 3.
S - 4.
An important point after buying a device Furuno SC-50/110 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Furuno SC-50/110 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Furuno SC-50/110 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Furuno SC-50/110 you will learn all the available features of the product, as well as information on its operation. The information that you get Furuno SC-50/110 will certainly help you make a decision on the purchase.
If you already are a holder of Furuno SC-50/110, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Furuno SC-50/110.
However, one of the most important roles played by the user manual is to help in solving problems with Furuno SC-50/110. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Furuno SC-50/110 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center