WARNING
CAUTION
Do no turn on the equipment with the transducer out of water.
Do not open the equipment.
There are no uer-serviceable parts inside.
The transducer may be damaged.
The picture is not refreshed when picture advancement is stopped.
Do not disassemble or modify the equipment.
Fire, electrical shock or serious injury can result.
Maneuvering the vessel in this condition may result in a dangerous situation.
Immediately turn off the power at the switchboard if the equipment is emitting smoke or fire.
Use the proper gain setting.
Incorrect gain may produce wrong depth indication, possibly resulting in a dangerous situation. See "Adjusting the gain" on page 7 for details.
Continued use of the equipment can cause fire or electrical shock. Contact a FURUNO agent for service.
Do not maneuver the vessel based on the depth indication alone.
The high quality LCD shows 99.99% of its pixels. The remaining .01% may drop out or brighten, due to the pro- perty of the LCD, however this is not a sign of malfunction.
Grounding may result.
Use the proper fuse.
A warning label is attached to the equipment. Do not remove the label. If the label is missing or damaged, contact a FURUNO agent or dealer.
Fuse rating is shown on the equipment. Use of a wrong fuse can result in damage to the equipment.

WARNING
CAUTION
Turn off the power at the switchboard before beginning the installation.
Do not install the equipment where air bubbles and noise are present.
Fire or electrical shock can result if the power is left on.
Performance will be affected.
The following are guidelines for handling of the transducer cable.
Be sure no water leaks in at the trans- ducer or sensor mounting location.
- Do not locate near oils and fuels. - Locate it in a safe place. - Do no paint the cable.
Water leakage can sink the vessel. Also confirm that the transducer and sensor will not loosen by ship's vibration. The installer of the equipment is solely responsible for the proper installation of the equipment. FURUNO will assume no responsibility for any damage associated with improper installation.
The sheath of the cable is made of chloroprene rubber (or polychloride vinyl). For this reason do not paint the cable.
Do not turn on the equipment with the transducer out of water.
Use the specified power cable.
Use of other power cable may result in fire.
The transducer may be damaged.
Observe the following compass safe distances to prevent interference to a magnetic compass:

Features
The FURUNO LS-4100 is a dual frequency (50 kHz and 200 kHz) monochrome LCD echo sounder. Comprised of a display unit and a transducer, the LS-4100 displays underwater conditions on a bright 5-inch monochrome LCD. The main features of the LS-4100 are
Congratulations on your choice of the FURUNO LS-4100 5” Echo Sounder. We are confident you will see why the FURUNO name has become synonymous with quality and reliability. For over 50 years FURUNO Electric Company has enjoyed an enviable reputation for innovative and dependable marine electronics equipment. This dedication to excellence is furthered by our extensive global network of agents and dealers. This equipment is designed and constructed to meet the rigorous demands of the marine environment. However, no machine can perform its intended function unless operated and maintained properly. Please carefully read and follow the recommended procedures for operation and maintenance. We would appreciate hearing from you, the end-user, about whether we are achieving our purposes. Thank you for considering and purchasing FURUNO equipment.


Equipment lists


Standard supply · Optional equipment

Cursor Pad Selects menu items; shifts VRM.
Selects display mode.
Opens/closes menu; escapes from current operation.
Adjusts gain.
Selects basic display range.
MARK
Outputs L/L position to external equipment; registers selected position as waypoint.
POWER
LS-4100
BRILL
Long press: Turns power on/off. Momentary press: Adjusts display contrast and brilliance.
How to remove the hard cover
Place your thumbs at the center of the cover, and then lift the cover while pressing it with your thumbs.
Press the [POWER/BRILL] key more than one second to turn on the power. The unit beeps, the startup screen appears, and then the equipment checks the ROM and RAM for proper operation and displays program number. (If “NG” (No Good) appears, try to press any key except the [POWER/BRILL] key to start operation. However, the equipment may not work properly. Contact your dealer.) You may press any key after the completion of the equipment check to start operation sooner.

Display unit

Note 1: When the power is reapplied after turning off the equipment with minimum brilliance, minimum brilliance will be set after the equipment goes through its initial start up. (The start up screen appears with the maximum brilliance.) Adjust the brilliance as necessary. Note 2: Setting windows other than those on menus are erased if there is no operation within about seven seconds.
FURUNO ELECTRIC CO., LTD.
Start-up screen To turn off the power, press and hold down the [POWER/BRILL] key until the screen goes blank. The time remaining until power is turned off is counted down on the screen. Note: The example screens shown in this manual may not match the screens you see on your display. The screen you see depends on your system configuration and equipment settings. 1.3 Adjusting Display Contrast, Brilliance
** Program version no.
Seven displays are available: single frequency (50 or 200 kHz), dual frequency, marker-zoom, bottom-zoom, bottom-lock, and nav data (two displays). 1. Press the [MODE] key to show the mode selection window.
SINGLE FREQ. DUAL FREQ. MARKER ZOOM BOTTOM ZOOM BOTTOM LOCK NAV DATA-1 NAV DATA-2 50kHz 200kHz Mode selection window
4 Brilliance/contrast adjustment window
Min Max · Min Max

Dual frequency display
The 50 kHz picture appears on the left; the 200 kHz picture on the right. This display is useful for comparing the same picture with two different transmitting frequencies.
The sounder uses ultrasonic signals to detect bottom conditions. The lower the frequency of the signal, the wider the detection area. Therefore, the 50 kHz frequency is useful for general detection and judging bottom condition. 200 kHz

The higher the frequency of the ultrasonic signal the better the resolution. For this reason the 200 kHz frequency is ideal for detailed observation of fish schools.
80 Dual frequency display
This mode expands chosen area of the normal picture to full vertical size of the screen on the left-half window. You may specify the portion to expand by operating the VRM (Variable Range Marker), which you can shift with ▲ or ▼. The area between the VRM and zoom range marker is expanded.
Frequency and coverage area


This section is zoomed

Nav data displays
This mode expands bottom and bottom fish in the range width set with ZOOM RANGE of the SYSTEM menu. This mode is useful for determining bottom contour. When the bottom depth increases, the display shift to keep the bottom echo at the lower part of the screen.
The nav data displays appear on the left of the screen. Data other than depth requires appropriate sensor. You can display between two and four items in a nav data display and choose the item and order to display them. See paragraph 1.16 to choose the items to display, “NAV DATA-1” and “NAV DATA-2” in paragraph 2.1 to choose the number of items to display.


Bottom-zoom display Bottom-lock display
The bottom-lock display provides a normal picture on the right half of the screen and a 15 feet (5 meter)* wide layer in contact with the bottom is expanded onto the left half of the screen. This mode is useful for detecting bottom fish. * = Operator selectable


This section is zoomed
Sample NAV DATA displays

Auto mode options window 4. Use ▲ or ▼ to choose option or set numeric value. 5. Press the [MENU/ESC] key to close the menu, or press ◄ to continue menu operation. 1.6 Automatic Operation
The LS-4100 has three menus: Main, System and Installation. Below is the basic menu operating procedure. 1. Press the [MENU/ESC] key to open the main menu. Page 1 or Page 2 of the main menu appears depending on the page last used.
AUTO MODE Off SHIFT : 0ft PIC. ADVANCE : 1/1 NOISE LIMIT : Off CLUTTER : Off SIGNAL LEVEL : Off A-SCOPE : Off HUE : Day WHITE LINE : Off DEEP GAIN : Low
The automatic function automatically chooses the proper gain, range scale and clutter. It works as follows:
Page no. Main menu, page 1
GOTO WPT Off WAYPOINT LIST...
The automatic mode provides two choices of modes: cruising and fishing. 1. Press the [MENU/ESC] key to open the main menu. 2. Press ▲ to choose AUTO MODE from page 1 of the menu. 3. Press ► to open the mode options window. 4. Choose Cruising or Fishing as appropriate.
ALARM MENU... SYSTEM MENU...
Main menu, page 2
“Cruising” is for tracking the bottom; “Fishing” is for searching fish schools. Since “Cruising” uses a higher clutter rejection setting than fishing, it is not recommended for fish detection - weak fish echoes may not be displayed. “Fishing” clearly displays weaker echoes.
Off Cruising Fishing · (1/2) · (2/2)

(Auto-Cruising) at the top left corner on the screen. Note: When in the auto mode, SHIFT and CLUTTER cannot be adjusted manually. Range offset
To display the bottom tail in detail in the automatic mode, offset the range as below. 1. Press the [+] or [-] key of the [RANGE] key.
The basic range and range shifting functions used together give you the means to choose the depth you can see on the screen. The basic range can be thought of as providing a “window” into the water column and range shifting as moving the “window” to the desired depth. Choosing basic range
Auto range offset window
The basic range may be chosen with the [RANGE] key from the eight ranges shown in the table shown below. (“P/B” in the table means Passi/Braza.) The setting range can be arranged through the SYSTEM menu.
Gain offset lets you override automatic gain adjustment. 1. Press the [GAIN] key.

Min Max ±0
Auto gain offset window
*Japanese unit of depth measurement 1. Press the [+] or [-] key of the [RANGE] key and the display should now look something like the one on at the top of the next page. 2. Press the [+] or [-] key of the [RANGE] key again to choose a basic range.
(Auto-Fishing) or · +0 ft · Default ranges

1000ft 600ft 400ft 200ft 120ft 60ft 30ft 15ft Basic ranges (default) 3. Press the [MENU/ESC] key to close the window. Shifting the range
The [GAIN] key adjusts the sensitivity of the receiver. Generally, use a higher gain setting for greater depths and a lower setting for shallower waters.
Use the proper gain setting.
Incorrect gain may produce wrong depth indication, possibly resulting in a dangerous situation.
The basic range may be shifted up or down in the manual mode as follows:

Window can be shifted up and down to select the depth.
Gain too high Gain proper Gain too low
Examples of proper and improper gain
Range and display shift concept


The VRM (Variable Range Marker) functions to measure the depth to fish schools, etc. 1. Press ▲ or ▼ to place the VRM on the object which you wish to measure range. 2. Read the VRM depth just above the VRM.
Picture and picture advancement speed

Stop 1/16 1/8 1/4 1/2 1/1 2/1 4/1
Picture advance options window 4. Use ▲ or ▼ to choose picture advance speed desired. The fractions in the options window denote the number of scan lines produced per transmission. For example, 1/8 means one scan line is produced every 8 transmissions. “Stop” freezes the display and it is convenient for taking a photo.
The picture advance speed determines how quickly the vertical scan lines run across the screen. When choosing a picture advance speed, keep in mind that a fast advance speed will expand the size of the fish school horizontally on the screen and a slow advance speed will contract it. Note that the picture is not refreshed when picture advancement is stopped. Therefore, use caution when steering the vessel under this condition.

The picture is not refreshed when picture advancement is stopped.
Maneuvering the vessel in this condition may result in a dangerous situation.

1.11 Suppressing Low Level Noise
Interference from other acoustic equipment operating nearby or other electronic equipment on your boat may show itself on the display as shown in the figure below. To suppress interference, do the following: 1. Press the [MENU/ESC] key to open the main menu. 2. Use ▲ or ▼ to choose NOISE LIMIT from page 1 of the menu. 3. Press ► to show the options window. 4. Use ▲ or ▼ to choose the degree of suppression desired; Off, Low, Medium, or High (highest). 5. Press the [MENU/ESC] key to close the menu.
Low intensity “speckles” may appear over most of screen. This is mainly due to sediment in the water or noise. These can be suppressed by adjusting CLUTTER on the menu. When the automatic mode is on, clutter is automatically rejected. To suppress low level noise in manual sounder operation, do the following: 1. Press the [MENU/ESC] key to open the main menu. 2. Use ▲ or ▼ to choose CLUTTER from page 1 of the menu. 3. Press ► to show the options window. 4. Use ▲ or ▼ to choose the degree of suppression desired; 1, 2, 3 ,4, 5 or 6. The higher the number the greater the suppression. 5. Press the [MENU/ESC] key to close the menu. To turn off low-level noise suppression, choose Off at step 4 and then press the [MENU/ESC] key.


Interference from other sounder
Turn the noise limiter off when no interference exists, otherwise weak echoes may be missed.
Electrical interference · Forms of interference · Clutter appearance

1.13 A-scope Display
This display shows echoes at each transmission with amplitudes and tone proportional to their intensities, on the right 1/4 of the screen. It is useful for estimating the kind of fish school and bottom composition. Note: In the dual frequency display, the A-scope display is only available with the high frequency display.
Sediment in the water or reflections from plankton may be painted on the display in low intensity tones.

Appearance of weak echoes

These weak echoes may be erased as follows: 1. Press the [MENU/ESC] key to open the main menu. 2. Use ▲ or ▼ to choose SIGNAL LEVEL from page 1 of the menu. 3. Press ► to show the options window. 4. Use ▲ or ▼ to choose the degree of suppression desired; Off, Low, or High (highest). 5. Press the [MENU/ESC] key to close the menu. To turn off the signal level function, choose "Off" at step 4 and then press the [MENU/ESC] key.
Weak reflection (fish or noise)
1. Press the [MENU/ESC] key to open the main menu. 2. Press ▲ or ▼ to choose A-SCOPE from page 1 of the menu. 3. Press ► to show the options window. 4. Press ▲ or ▼ to choose the A-scope presentation type desired. Normal: Display shows echoes at each transmission with amplitudes and tone proportional to their intensities. Peak: Peak-hold amplitude picture. 5. Press the [MENU/ESC] key to close the menu. To turn off the A-scope display, choose Off at step 4 and then press the [MENU/ESC] key.

MENU from page 2 on the menu. 3. Press the ► to show the ALARM menu.
The LS-4100 has six conditions which generate both audio and visual alarms: bottom alarm, normal fish alarm, bottom lock fish alarm, water temperature alarm, arrival alarm and speed alarm. (The water temperature, arrival and speed alarms require appropriate sensors.) Bottom alarm: The bottom alarm alerts you when the bottom is within the alarm range set. To activate the bottom alarm the depth must be displayed. Fish (normal) alarm: The fish (normal) alarm tells you when fish are within the preset alarm range. Fish (bottom lock) alarm: The fish (bottom lock) alarm, available with the bottom-lock mode, sounds when fish are within a certain distance from the bottom. Note that the bottom zoom display must be turned on to use this alarm. Water temperature alarm: The water temperature alarm alerts when the water temperature is within (Inside alarm) the alarm range set or under/over (outside alarm) the range set. Speed alarm: The speed alarm alerts you when the speed is within (Inside alarm) or under/over (Outside alarm) the preset speed. Arrival alarm: The arrival alarm alerts when you are near a waypoint by the distance set. Activating an alarm
BOTTOM On FROM : 5ft RANGE : 10ft FISH(Normal) : On FROM : 5ft RANGE : 10ft FISH(B/L) : On FROM : 8ft RANGE : 1.0ft FISH LEVEL : Medium
Page no.
Gray characters mean alarm is inactive. Alarm menu
Temp, Speed Alarm Types Fish, Arrival, Bottom Alarm On/Off Alarm options 6. Use ▲ or ▼ to choose alarm type:
Off: Alarm off, On: Alarm on Inside: Alarm generated when speed (or water temperature) is within the range set. Outside: Alarm generated when speed (or water temperature) is outside the range set.


1.0 kt
Alarm range Starting point
Speed Depth, temperature, speed setting
window 10. Use ▲ or ▼ to set starting depth, temperature or speed as appropriate. For FISH (B/L), the starting depth is the range from the bottom. 11. Press ◄ to close the window. 12. Press ▼ to choose RANGE. 13. Press ► to show the options menu. 14. Use ▲ or ▼ to set alarm range. 15. For the bottom alarm, temperature alarm, speed alarm or arrival alarm, press the [MENU/ESC] key to finish. For a fish alarm, press ◄ to close the window, and then go to step 16. 16. Press ▼ to choose FISH LEVEL. 17. Press ► to show the options menu.
Alarm range marker l Bottom alarm, Fish alarm (normal): Right l Fish alarm (bottom/lock): Left
* Alarm icon (Appropriate icon appears to show which alarm has been violated.)
: Bottom alarm : Fish alarm (normal) : Fish alarm (B/L) : Temperature alarm (°C or °F shown) : Speed alarm : Arrival alarm
How the alarm works
The buzzer sounds and the appropriate alarm icon appears and flashes when an alarm is violated. You can silence the buzzer by pressing any key. However, the buzzer will sound whenever the alarm setting is violated. Note: The audio and visual alarms are released against the last-violated alarm when multiple alarms are active. 1.15 Waypoints
Weak Medium Strong Fish level options
Weak: Weak echoes (weakest tone on level bar) Medium: Medium strength echoes (middle tone on level bar) Strong: Strong echoes (darkest tone on level bar)
Waypoints may be used to:


2. Press the cursor pad to set the cursor where desired. Picture advancement is stopped until step 3 is completed, and the instruction window is integrated into the nav display. 3. Press the [MARK] key again. When TLL or FURUNO-TLL is selected at TLL OUTPUT on the System menu, the latitude and longitude position at the cursor is output to the navigator. A vertical line marks location. Further, the display shows the waypoint name (next sequential number) and position of the location selected at step 2.
Waypoint window, name entry 6. Use ▲ or ▼ to set character; ◄ or ► to shift cursor. The name may consist of 10 alphanumeric characters. Note: Character order is 0→1…9→ - →A→B…Z→ _ →0…

WAYPOINT LIST
0101 0203 03 [MENU]: Exit
Waypoint list 4. Press ▲ or ▼ to choose an empty waypoint and press ►. Press ► again.
Set a destination waypoint to find range, bearing and time-to-go to that point. You can see range and bearing to a waypoint. Time-to-go is shown on the Time to Go digital display. 1. Press the [MENU/ESC] key to open the main menu. 2. Use ▲ or ▼ to choose GOTO WPT from page 2 of the menu. 3. Press ► to open the waypoints list.
New waypoint window, name entry
Off 01 02 03 04
1. Press the [MENU/ESC] key to open the main menu. 2. Use ▲ or ▼ to choose WAYPOINT LIST from page 2 of the menu. 3. Press ► to open the waypoints list. 4. Use ▲ or ▼ to choose a waypoint and press ►. 5. Use ▲ or ▼ to choose the item to edit. (name, latitude or longitude) 6. Press ► to open the data entry window. 7. Use ▲ or ▼ to set character; ◄ or ► to choose location. 8. Press ► to choose ENT . 9. Press the [MENU/ESC] key.
Erase? · Waypoint list

The user may arrange the nav data displays as desired. 1. Use the [MODE] key to show the NAV DATA-1 or 2 display, whichever you want to set up. 2. Press the [MENU/ESC] key to close the mode selection window. 3. Press the cursor pad to display the NAV DATA SETUP window.
Items displayable in (1) - (3): depth, position, course, range and bearing, trip distance, odometer, water temperature, heading, air pressure, time-to-go to destination waypoint, XTE*, speed*, wind speed and direction*, destination waypoint data*, compass* Items displayable in (4) - (9): depth, position, speed, course, range and bearing, trip distance, odometer, water temperature, heading, air pressure, time-to-go to destination waypoint, XTE*, wind speed, wind direction
* = Graphic display
Nav data window and item displayable 6. Press the [MENU/ESC] key to finish. Note: You can choose the number of items to show in a nav data display with NAV DATA-1 and NAV DATA-2 on the System menu.
NAV DATA SETUP window
XTE
10 0 1 0.5 0 0.5 1 0.25 nm
XTE GRAPHIC
SPEED GRAPHIC
Speed 10.3 m/s
Wpt 03 Rng 0.19nm Brg 321° XTE 0.00nm Cse 333°
Bearing, Course Destination waypoint direction
Bearing to destination waypoint
E
1 0.5 0 0.5 1
COMPASS GRAPHIC

Depth 32.8 ft
Temperature 69.8 ° F
Speed 19.3 kt
Wind Speed APP* 8.0 m/s
Wind Dir. APP* 138 °
DEPTH
WATER TEMPERATURE
SPEED
WIND SPEED
WIND DIRECTION
Heading TRUE/MAG# 318 °
Course 123 °
30 ° 00.065'N 130 ° 00.574'E
1018 hpa
1.21 nm
POSITION
HEADING
COURSE
RANGE & BEARING
AIR PRESSURE
*: APP or TRUE, depending on menu setting. #: TRUE or MAG depending on menu setting. &: To destination waypoint
Time to Go 00 H 30 M
Odometer 56 nm
TIME-TO-GO
ODOMETER
= GPS receiving status (Displays when connecting with GP-310B/320B and "In/Out" is selected at the Installation menu.) NO FIX: Position cannot be found. GPS 2D: 2D (dimension) GPS position fix GPS 3D: 3D GPS fix GPS W2D: 2D WAAS position fix GPS W3D: 3D WAAS position fix
display shows "- -" at the location where data is lost.
This section describes the menu items not previously mentioned. Page 1
The white line feature displays the leading edge of the bottom echo in white. This is useful for discriminating bottom fish near the bottom. 1. Press the [MENU/ESC] key to display the main menu. 2. Use ▲ or ▼ to choose WHITE LINE from page 1 of the menu. 3. Press ► to show the options window.
Two picture color arrangements are available: Day and Night. Day shows echoes on a white background; Night shows them on a black background. 1. Press the [MENU/ESC] key to display the menu. 2. Use ▲ or ▼ to choose HUE from page 1 of the menu. 3. Press ► to show the options window.

0.0 0 50k
Fish school clearly shown
If the gain is too high or too low, or the gain for the low and high frequencies appears unbalanced, you can compensate it as follows: 1. Press the [MENU/ESC] key to open the main menu. 2. Use ▲ or ▼ to choose GAIN ADJ 200 or GAIN ADJ 50 from page 2 of the menu. 3. Press ► to show to the options window. 4. Use ▲ or ▼ to set the amount. The setting range is –50 to +50. 5. Press the [MENU/ESC] key to close the menu. DRAFT
52.6 White Line OFF White Line ON (Mesh)
How white line works DEEP GAIN
“Deep Gain” compensates for propagation attenuation of the ultrasonic waves. It does this by equalizing echo presentation so that fish schools of the same size appear in the same density in both shallow and deep waters. In addition, it reduces surface noise. 1. Press the [MENU/ESC] key to open the main menu. 2. Use ▲ or ▼ to choose DEEP GAIN from page 1 of the menu. 3. Press ► to show to the options window. 4. Choose Low, Medium, or High as appropriate. High provides the greatest degree of gain reduction against short range echoes. 5. Press the [MENU/ESC] key to close the menu. Page 2
The default depth display shows the distance from the transducer. If you would rather show the distance from the sea surface, set your ship’s draft as follows: 1. Press the [MENU/ESC] key to open the main menu. 2. Use ▲ or ▼ to choose DRAFT from page 2 of the menu. 3. Press ► and then use ▲ or ▼ to set draft. The setting range is –15.0 to +50.0 (meters, feet). 4. Press the [MENU/ESC] key to close the menu.
This item resets trip distance to “0.” 1. Press the [MENU/ESC] key to open the main menu. 2. Use ▲ or ▼ to choose TRIP RESET? from page 2 of the menu.

The System menu mainly consists of items which once set do not require frequent adjustment. You may display this menu by choosing SYSTEM MENU at page 2 of the main menu and pressing ►.
LANGUAGE: The system language is available in English, several European languages and Japanese. To change language, select language desired and press the [MENU/ESC] key. DEPTH UNIT: Choose unit of depth measurement from meters, feet, fathoms, passi/braza and hiro (Japanese). SPEED UNIT: Choose unit of speed measurement from knots, miles per hour and kilometers per hour. Requires speed data. WIND UNIT: Choose unit of wind speed measurement from m/s, kt, km/h, and mph. Requires wind speed data. TEMP UNIT: Choose unit of temperature measurement; Celsius or Fahrenheit. Requires temperature data. TEMP GRAPH: Turns the water temperature display on or off. The temperature scale range is 16° (°F) in “Narrow”; 40° (°F) in “Wide”. Requires water temperature data.

NAV DISPLAY Temp/Speed NMEA0183 : Ver 2.0 TLL OUTPUT : Off BEARING : True WIND SPD/DIR : Apparent TRIP SOURCE : Own
TEMP SOURCE : Own SPEED SOURCE : Own TEMP CALIB. : +0.0°F (±40) SPEED CALIB. : +0% (±50)
Own speed Own temp 10.0 kt 16.2°F
0.0 0 50k
63.8°F 16.2kt
m 52.6
Water temperature display (wide, °F)

NAV DATA-1, -2: Choose the number of navigation data items to display on the nav data displays, from two, three or four items. Requires appropriate nav data. WATER TYPE: Choose the water type with which to use the LS-4100, from Salt or Fresh. KEY BEEP: Turn key beep on or off. BATT VOLTAGE: Turn the battery voltage indication (appears at the top right corner on the screen) on or off. When on it replaces the picture advance speed indication. Page 2
BEARING: Ship’s course and bearing to a waypoint may be displayed in true or magnetic bearing. Magnetic bearing is true bearing plus (or minus) earth’s magnetic deviation. Requires bearing data. WIND SPD/DIR: Choose the wind speed and direction reference from true and apparent. Requires wind sensor. Apparent: The direction (in relation to ship’s bow) and speed of the wind as it appears to those on board, relative to the speed and direction of the boat; combination of the true wind and the wind caused by the boat's movement. True: The speed and direction (in relation to ship’s bow) of the wind felt or measured when stationary. TRIP SOURCE: Choose speed source for the trip distance indication; Own (transducer with speed sensor or separate speed sensor) or NMEA. TEMP SOURCE: Choose source of water temperature input; Off, Own (transducer with water temperature sensor or separate temperature sensor), or NMEA. SPEED SOURCE: Choose source of speed input; Off, Own (transducer with speed sensor or separate speed sensor), or NMEA. Requires speed data. TEMP CALIB.: If the water temperature sensor-generated water temperature indication is wrong, you can correct it here, when “Own” is selected as temperature source. For example, if the water temperature indication is 2° higher than actual water temperature, enter -2. The setting range is -40°F to +40°F.
NAV DISPLAY: Choose the nav data to display in the nav data window at the top left-hand corner. You may choose from temperature/speed, latitude/longitude, range and bearing, course over ground, trip distance or wind speed. Requires appropriate nav data.
40.7°F 16.2kt Nav window
NMEA0183: Choose NMEA version of navigator; Ver. 1.5, Ver. 2.0 or Ver. 3.0. TLL OUTPUT: Enables/disables output of TLL (Target Latitude, Longitude) position when the [MARK] key is operated. “TLL” outputs latitude and longitude position. “FURUNO-TLL,” available with connection of navigator that can output FURUNO TLL, outputs latitude and longitude, water temperature, depth, etc.

SPEED CALIB.: If the speed sensor-generated speed indication is wrong, you can correct it here, when “Own” is selected as speed source. For example, if the speed indication is 10% lower than actual speed, enter +10. The setting range is –50% to +50%. Page 3
BASIC RANGE 1 - BASIC RANGE 8: Set range of each of the eight basic ranges. (Selectable range: 7 to 1500 ft)
Note 2: A range may not be lower than the range preceding it. For example, if basic range 3 is 60 feet, basic range 4 must be greater than 60 feet. ZOOM RANGE: Choose the range to zoom in the marker-zoom and bottom-zoom modes. You may choose a range between 7 and 150 feet (2 and 50 meters). B/L RANGE: The expansion width for the bottom-lock display can be chosen from 10 to 30 feet (3 and 10 meters). ZOOM MARKER: The zoom marker appears in the normal, bottom marker and bottom zoom displays and marks the area which is expanded in the bottom marker and bottom zoom pictures. You can turn the marker on or off as desired.

WARNING
ELECTRICAL SHOCK HAZARD Do not open the equipment.
Marine life on the transducer face will result in a gradual decrease in sensitivity. Check the transducer face for cleanliness each time the boat is dry-docked. Carefully remove any marine life with a piece of wood or fine-grade sandpaper. 3.4 Replacing the Fuse
Only qualified personnel should work inside the equipment.
Regular maintenance is essential for good performance. Checking the items listed in the table below monthly will help keep your equipment in good shape for years to come.
The fuse in the power cable protects the system from reverse polarity of the power supply and equipment fault. If the fuse blows, find the cause before replacing it. Use only a 1A fuse (FGMB 1A 125V, Code No. 000-114-805) or equivalent. Using the wrong fuse will damage the unit and void the warranty.
Check cable for damage.
Power cable, transducer cable plug
Check that they are tightly fastened. Refasten if necessary.
Check for corrosion. Clean if necessary.
Use the proper fuse.
Fuse rating is shown on the equipment. Use of a wrong fuse can result in fire and damage the equipment.
Check voltage. If out of rating correct problem.
3.2 Cleaning the Display Unit
A battery icon appears when the battery voltage is too high or too low.
Dust or dirt on the display unit can be removed with a soft cloth. If desired, a water-moistened cloth may be used. Use special care when cleaning the LCD since it scratches easily. Do not use chemical cleaners to clean the display unit - they can remove paint and markings.
Battery icon and meaning
Voltage is lower than 10 VDC. If the
voltage goes below 9 V, the equipment is automatically turned off.
Voltage is higher than 16.5 VDC. If the
voltage goes higher than 17.5 V, the equipment is automatically turned off.

3.7 Diagnostics
The table below provides basic troubleshooting procedures which the user may follow to restore normal operation.
If you feel your unit is not working properly, conduct the diagnostic test to find the problem. If you cannot restore normal operation, contact your dealer for advice. 1. Turn on the power while pressing the [MENU/ESC] key. Continue pressing the [MENU/ESC] key until the Installation menu appears.
If… Then check …
neither echo nor fixed range scale appears
no echo appears but the fixed range scale appears
echo appears but no zero line
SET BOTTOM LEVEL ..
* = Setting cannot be changed when NMEA PORT setting is "In/In." Installation menu
there is extreme interference or noise
the speed/water temperature readout is unrealistic or not present
Water Temperature, Speed Battery Voltage Temperature inside display unit (Unit fixed at °C.)
the position readout is unrealistic or not present
Program No. 0252318-01.** Push [MENU] 3 times to exit.
** = Program version no.
Only when GP-310B is connected. (For GP-320B: 4850238**) Test display

4. The ROM, RAM and NMEA port are checked, with the results shown as OK or NG (No Good). For any NG, request service. (A special connector is required to test the NMEA port. Nothing appears if no connector is connected.) 5. The squares at the right side of the test display are for checking the controls. Press each key and the arrows on the Cursor Pad one by one. A control’s corresponding on-screen square “lights” in black if the control is normal. 6. To return to the Installation menu, press the [MENU/ESC] key three times. 7. To restore normal operation, turn off the power and turn it on again. 3.8 Test Pattern
The memory can be cleared to start afresh with default menu settings. 1. At the installation menu, press ▼ to choose MEMORY CLEAR. 2. Press ► to open the options window.
: YES : NO Clear memory display
This feature tests for proper display of tones. 1. On the Installation menu, press▼ to choose LCD PATTERN. 2. Press ► to start the test. The entire screen is black. 3 Press ► again and the screen turns white. 4. Press ► again and the screen shows a four-toned display. 5. Press ► again to return to the Installation menu. 6. To restore normal operation, turn off the power and then it on again.
Test patterns

Mounting considerations
See the instructions on the bulkhead or flush mounting template (supplied). 4.2 Thru-hull Mount Transducer
The thru-hull mount transducer (520-5PSD, 520-5MSD) provides the best performance of all, since the transducer protrudes from the hull and the effect of air bubbles and turbulence near the hull skin is reduced. When the boat has a keel, the transducer should be at least 30 cm away from it. Typical thru-hull mountings are shown in the figure on the next page. The performance of this sounder is directly related to the mounting location of the transducer, especially for high-speed cruising. The installation should be planned in advance, keeping the standard cable length (8 m) and the following factors in mind:

submerged, even when the boat is rolling, pitching or up on a plane at high speed.

Thru-hull mount transducer dimensions
Typical thru-hull mount transducer installations Procedure for installing the thru-hull mount transducer
1. With the boat hauled out of the water, mark the location chosen for mounting the transducer on the bottom of the hull. 2. If the hull is not level within 15° in any direction, fairing blocks made out of teak should be used between the transducer and hull, both inside and outside, to keep the transducer face parallel with the water line. Fabricate the fairing block as shown below and make the entire surface as smooth as possible to provide an undisturbed flow of water around the transducer. The fairing block should be smaller than the transducer itself to provide a channel to divert turbulent water around the sides of the transducer rather than over its face.
l Position 1/2 to 1/3 of the hull from stern. l 15 to 30 cm off center line (inside first lifting strakes.)

l Within the wetted bottom area l Deadrise angle within 15°
Suitable transducer mounting locations
Cork Washer

DO NOT paint the transducer. Performance will be affected. 4.3 Transom Mount Transducer
BOW Hole for stuffing tube
The transom mount transducer is very commonly employed, usually on relatively small I/O or outboard boats. Do not use this method on an inboard motor boat because turbulence is created by the propeller ahead of the transducer. 520-5PWD
Saw along slope of hull. Construction of fairing block
3. Drill a hole just large enough to pass the threaded stuffing tube of the transducer through the hull, making sure it is drilled vertically. 4. Apply a sufficient amount of high quality caulking compound to the top surface of the transducer, around the threads of the stuffing tube and inside the mounting hole (and fairing blocks if used) to ensure watertight mounting. 5. Mount the transducer and fairing blocks and tighten the locking nuts. Be sure that the transducer is properly oriented and its working face is parallel to the waterline. Note: Do not over-stress the stuffing tube and locking nuts through excessive tightening, since the wood block will swell when the boat is placed in the water. It is suggested that the nut be tightened lightly at installation and retightened several days after the boat has been launched. Transducer preparation
There are two methods of installation: flush with hull (for flat hulls) and projecting from hull (for deep V-hulls).

520-5PWD mounting locations Installing the 520-5PWD on a flat hull
A suitable mounting location is at least 50 cm away from the engine and where the water flow is smooth. 1. Drill four pilot holes in the mounting location. 2. Attach the transducer to the bracket with 5 x 20 tapping screws (supplied). 3. Adjust the transducer position so the transducer faces right to the bottom.
Before putting the boat in water, wipe the face of the transducer thoroughly with a detergent liquid soap. This will lessen the time necessary for the transducer to have good contact with the water. Otherwise the time required for complete “saturation” ill be lengthened and performance will be reduced.


No. 2


Transom mount transducer, mounted projecting from hull
No.1 M5 x 14

Choose the installation method depending on the rise angle of the hull.

2 to 5°
Mount at the stripe.
mounting flush with hull
Installing the transom mount transducer on a deep-V hull
This method is employed on deep-V hulls and provides good performance because the effects of air bubbles are minimal. Install the transducer parallel with water surface; not flush with hull. If the boat is placed on a trailer care must be taken not to damage the transducer when the boat is hauled out of the water and put on the trailer.
Referring to “Installing the 520-5PWD” in the left column for mounting of the bracket and the figure shown on the top of next page, install the 525-5PWD to the transom.


15 cm 15 cm
Inside-hull transducer mounting location
The thru-hull mount transducer (520-5PSD, 520-5MSD) may also be installed inside the hull, following the procedure below. Necessary tools
You will need the following tools:


3. Press the [MODE] key to choose SINGLE FREQ. 4. Choose 50 kHz or 200 kHz, and then press the [MENU/ESC] key to close the mode menu. 5. Press the [MENU] to show the main menu, and then press ▲ to select Auto mode. 6. Press ► ▲ to choose Off. 7. Press the [MENU/ESC] key. 8. Press the [GAIN] key to set the gain to “5” and then press the [MENU/ESC] key. 9. Press the [RANGE] key to set the range to 10 meters (feet) and then press the [MENU/ESC] key. 10. If the bottom is displayed in dark gray and the depth indication appears, the mounting location is suitable. Go to “Final preparation.” 11. If the bottom is not displayed in dark gray tone, the mounting location may be unsuitable. Do the following: a) Press the [POWER/BRILL] key to
133 mm 2.00"-12 UN threads
140 mm Triducer 525ST-MSD 525ST-PWD
The Transom Mount Transducer or TRIDUCER® Multisensor with Integral Release Bracket 525ST-PWD is manufactured by AIRMAR Co. These instructions are also included with the sensor. Pre-test for speed and temperature
turn off the power. b) Gently dismount the transducer
with a piece of wood. c) Reattach the transducer
elsewhere as shown in “Attaching the transducer.” d) Check the installation again. Final preparation
Connect the sensor to the instrument and spin the paddlewheel. Check for a speed reading and the approximate air temperature. If there is no reading, return the sensor to your place of purchase. Tools and materials needed
Support the transducer with a piece of wood to keep it in place while it is drying. Let the transducer dry 24-72 hours. 4.5 Optional Triducer
Scissors Masking tape Safety goggles Dust mask Electric drill Drill bit for:
The optional triducer 525ST-MSD is designed for thru-hull mounting. For how to install this transducer see paragraph 4.2.


Cable clamp holes: 3mm or 1/8” Screwdrivers Straight edge Marine sealant Pencil Zip-ties Water-based antifouling paint (mandatory in salt water). Mounting location
75 mm(3") minimum beyond swing radius
Mounting location on single drive boat
To ensure the best performance, the sensor must be submerged in aeration-free and turbulence-free water. Mount the sensor close to the centerline of the boat. On slower heavier displacement hulls, positioning it farther from the centerline is acceptable. Allow adequate space above the bracket for it to release and rotate the sensor upward.
Height without speed sensor 191mm (7-1/2") Height with speed sensor 213mm (8-1/2") Height required at mounting location

for starboard side of boat
Drill at locations labeled "B" for the following transom angles:
16° through 22°
A A A
Drill at locations labeled "A" for the following transom angles:
Note 1: Do not mount the sensor in an area of turbulence or bubbles: near water intake or discharge openings; behind strakes, struts, fittings, or hull irregularities; behind eroding paint (an indication of turbulence). Note 2: Avoid mounting the sensor where the boat may be supported during trailering, launching, hauling, and storage. Note 3: For single drive boat, mount on the starboard side at least 75 mm (3”) beyond the swing radius of the propeller.
2° through 15°
Align arrow with bottom of transom
Align template vertically.

Slope of hull parallel to waterline
Align template arrow with bottom edge of transom. Positioning the template
P66 Installation template · Height · Deadrise angle

2°-10° transom
11° transom angle NO SHIM
19°-22° transom
angle shim with taper up shim with taper down
3. Using a 4 mm, #23, or 9/64” bit, drill three holes 22 mm (7/8”) deep at the locations indicated. To prevent drilling too deeply, wrap masking tape around the bit 22 mm (7/8”) from the point. Fiberglass hull: Minimize surface cracking by chamfering the gelcoat. If a chamfer bit or countersink bit is not available, start drilling with a 6mm or 1/4” bit to a depth of 1 mm (1/16”). 4. If you know your transom angle, the bracket is designed for a standard 13° transom angle. 11°-18° angle: No shim is required. Skip to step 3 in “Adjusting”. Other angles: The shim is required. Skip to step 2 of “Adjusting”. If you do not know the transom angle, temporarily attach the bracket and sensor to the transom to determine if the plastic shim is needed.

12-18° transom angle NO SHIM
angle too steep angle reversed
Sensor position and transom angle
2°-10° transom angle (stepped transom and jet boats): Position the shim with the tapered end down. 19°-22° transom angle (small aluminum and fiberglass boats): Position the shim with the tapered end up.
angle · parallel parallel parallel · slight angle


Attaching the sensor to the bracket

Hull projection 3 mm (1/8")
Vertical adjustment and cable routing
Route the sensor cable over the transom, through a drain hole, or thorough a new hole drilled in the transom above the waterline.
Attaching the sensor to the bracket
Never cut the cable or remote the connector; this will void the warranty. Always wear safety goggles and a dust mask. 1. If a hole must be drilled, choose a location well above the waterline. Check for obstructions such as trim tabs, pumps, or wiring inside the hull. Mark the location with a pencil. Drill a hole through the transom using a 19 mm or 3/4” bit (to accommodate the connector). 2. Route the cable over or through the transom. 3. On the outside of the hull secure the cable against the transom using the cable clamps. Position a cable clamp 50 mm(2”) above the bracket and mark the mounting hole with a pencil.

Step 1 Step 2

4. Position the second cable clamp halfway between the first clamp and the cable hole. Mark this mounting hole. 5. If a hole has been drilled in the transom, open the appropriate slot in the transom cable cover. Position the cover over the cable where it enters the hull. Mark the two mounting holes. 6. At each of the marked locations, use a 3 mm or 1/8” bit to drill a hole 10 mm (3/8”) deep. The prevent drilling too deeply, wrap masking tape around the bit 10 mm (3/8”) from the point. 7. Apply marine sealant to the threads of the #6 x 1/2” self-tapping screw to prevent water from seeping into the transom. If you have drilled a hole through the transom, apply marine sealant to the space around the cable where it passes through the transom. 8. Position the two cable clamps and fasten them in place. If used, push the cable cover over the cable and screw it in place. 9. Route the cable to the instrument being careful not to tear the cable jacket when passing it though the bulkhead(s) and other parts of the boat. To reduce electrical interference, separate the sensor cable from other electrical wiring and “noise” sources. Coil any excess cable and secure it in place with zip-ties to prevent damage.
Water temperature/speed sensor ST-02MSB and ST-02PSB, which are designed for thru-hull mounting, are optionally available. Install them as shown below. Mounting considerations
Choose a suitable mounting location considering the following:
1. Dry-dock the boat. 2. Make a hole of approx. 51 mm diameter in the mounting location. 3. Unfasten locknut and remove the sensor section. 4. Apply high-grade sealant to the flange of the sensor. 5. Pass the sensor casing through the hole. 6. Face the notch on the sensor toward boat’s bow and tighten the flange. 7. Set the sensor section to the sensor casing and tighten the locknut. 8. Launch the boat and check for water leakage around the sensor.


The ground wire (1.25 sq or more, local supply) should be as short as possible. The signal line ground is isolated from the chassis ground, however the power line is not insulated. Therefore, when connecting eternal equipment having positive ground, do not ground the signal line to the chassis. If excessive noise shows on the screen, the ground may be inadequate. In this case, attach a steel plate measuring 20 cm by 30 cm on the outside of the hull to provide a ground point. Connect the ground wire there. Use a “closed” type lug ( ) to make the connection at the display unit. Do not use an “open” type lug ( ). Optional equipment
Face "notch" toward bow.
Coat with silicone sealant. Brim
Connect the LS-4100 power/data cable assy MJ-A7SPF0005-020 (2 m, supplied) to the POWER, and the transducer cable to the XDR connector. Refer to the interconnection diagram to connect cables. Leave slack in cables to facilitate checking and maintenance.
The power supply port is commonly used for connection of external equipment such as a GPS receiver or wind indicator. Use the power/data cable MJ-A7SPF0005-020 (supplied) for connection referring the figure shown in the right column.


Cable tie How to fix fuse holder

Input data sentences (con’t)

Connect the optional water temp/speed sensor to the XDR connector with the optional converter connector (Type 02S4147) as shown below.
Sentence Meaning MWV Wind speed and angle RMA Recommended minimum specific LORAN-C data RMB Recommended minimum navigation information RMC Recommended minimum specific GPS/TRANSIT data VHW Water speed and heading VTG Course over ground and ground speed XTE Cross track error
Connect to XDR port at rear of display unit

Tape connectors with vulcaninzing tape and then vinyl tape to waterproof them. Bind tape ends with cable ties to prevent tape from unraveling.
From transducer From sensor

Sentence Meaning DBT (Ver. 1.5) Depth below transducer DPT (Ver. 2.0, Ver. 3.0) Depth
MTW* Water temperature RMB* (Ver. 2.0) Recommended minimum navigation information VHW* Water speed and heading TLL* Target position, output by [MARK] key. *= Available with connection of optional sensors/navaid
The tables below show the data sentences which can be input to and output from the LS-4100. The transmission speed for both input and output is 4800 bps. Data is output at two-second intervals.


NMEA port setup (NMEA PORT, NMEA MIX)
The installation menu mainly contains items which are set at installation. 1. Turn on the power while pressing the [MENU/ESC] key. Continue pressing the [MENU/ESC] key until the Installation menu appears.
The POWER port can function as an input port or input/output port. Change the setting to “In/In” when connecting GP-310B/320B and a wind sensor. When connecting the GP-310B/320B and a wind sensor, first turn on “GPS WAAS” (in the Installation menu) and then select “In/In” as the NMEA port setting. 1. Turn on the power while pressing and holding down the [MENU/ESC] key. Continue pressing the [MENU/ESC] key until the Installation menu appears. 2. Choose NMEA PORT, and then press ► to display the NMEA port options window. 3. Use ▲ or ▼ to choose In/Out or In/In as appropriate.
SET BOTTOM LEVEL ..
* = Setting cannot be changed when NMEA PORT setting is "IN/IN." Installation menu
SIMULATION: The simulation mode provides, without connection of the transducer, simulated operation of the equipment, using internally generated echoes. All controls are operative. The message “SIM” appears at the top right corner on the screen when the simulation mode is active. 1. At the installation menu, press ► to open the simulation mode options window. 2. Press ▼ to choose “On” to turn on the simulation mode. 3. Press the [POWER/BRILL] key about three seconds to turn off the power. 4. Press the [POWER/BRILL] key to turn on the power. “SIM” appears at the top right corner of the display. 5. To turn off the simulation mode, select Off at step 2.
In/Out: Input and Output (default setting) In/In: Input only (Available with connection of the GP-310B/320B and a wind sensor.)
Off: Outputs the data sentences of LS-4100 only.
On: Outputs the data sentences of LS-4100 and sentences which are input from other equipment.
Installation Menu · SIMULATION On

GPS WAAS: Chooses how to use the WAAS signal when connecting with a WAAS receiver, for example GP-320B. Note: WAAS is currently in the developmental phase. During the developmental phase the reliability and availability of the WAAS signal cannot be guaranteed. Therefore, any position data should be verified against other sources to confirm reliability. 1. Display the Installation menu. 2. Choose GPS WAAS and then press ► to open the GPS WAAS options window.
BOTTOM LEVEL: If the depth indication is unstable in automatic operation, or the bottom echo cannot be displayed in the darkest gray tone by adjusting the gain controls in manual operation, you may adjust the bottom echo level detection circuit, for both 50 kHz and 200 kHz, to stabilize the indication. Generally, lower the bottom level for inner hull installation where the receive level is too low. If the bottom level is too low it may be difficult to discriminate fish from the bottom, resulting in unstable depth indication. And if the bottom level is too high the depth indication may not appear. 1. At the installation menu, press ▼ to choose SET BOTTOM LEVEL and then press ►. Several seconds later the following display appears.
WAAS options window 3. Press ▲ or ▼ to choose “WAAS-02” (test signal). When the system becomes operational (in 2003), set to “00” (regular WAAS signal). 4. Turn off the power.
Off · Bottom level display

1 GENERAL
1.1 TX Frequency 50 kHz or 200 kHz, 50/200 kHz dual transmitting selectable 1.2 Transmit Method Single or dual transmitting 1.3 Output Power 300 Wrms 1.4 TX Rate Max. 500 pulse/min 1.5 Pulse-length 0.1 to 0.8 ms
2.1 Display system 5-inch monochrome LCD, 76 mm (W) x 100 mm (H), 240 x 320 dots 2.2 Display Mode Single frequency (high/low freq.), Dual-frequency, Zoom, Nav data-1/2 Marker zoom, Bottom zoom, Bottom-lock 2.3 Display Range Range Setting Range

1 2 3 4 5 6 7 8 Display range
Meter 5 10 20 40 80 150 200 300 2-500
Feet 15 30 60 120 200 400 600 1000 7-1500
Fathoms 3 5 10 20 40 80 100 150 1-250
Passi/Braza 3 5 10 30 50 100 150 200 1-300
2.4 Range Shift 0-500 m, 0-1500 ft, 0-250 fa, 0-300 p/b 2.5 Expansion Range Bottom-lock expansion: 3 to 10 m Sectional expansion: 2 to 50 m 2.6 Display Advance Speed 8 steps (Lines/TX; Freeze, 1/16,1/8,1/4,1/2,1/1,2/1, 4/1)
3.1 Input data sentences IEC61162-1/NMEA0183 Ver 1.5/2.0/3.0 GGA, RMA, RMB, RMC, BWC, GLL, HDT, HDG, VTG, VHW, MTW, MWV, MDA, XTE 3.2 Output data sentences IEC61162-1/NMEA0183 Ver 1.5/2.0/3.0, interval: 2 s MTW*, VHW*, DBT, DPT, RMB*, TLL* by key operating *: External data required
5 ENVIRONMENTAL CONDITION 5.1 Ambient Temperature Display unit: -15°C to +55°C 5.2 Relative Humidity 93% or less at 40°C 5.3 Waterproof IPX5
6.1 Display Unit N3.0












ECHO SOUNDER
魚群探知機
相互結線図
LS-4100
MJ-A10SRMD
TRANSDUCER 送受波器
XDRXDR SHIELD
10 9 8 7 6 5 4
520-5PWD 520-5MSD 520-5PSD
SPD0V/SHIELD TEMP NC NC TEMP0V XDR+
TITLE
名称
NAME
水温・船速センサー
TEMP/SPEED SENSOR
3 +12V
6 5 4 3 2
ST-02MSB
ST-02PSB
XDR
MJ-A10SPF
*4 02S4147
MJ-A6SRMD
MJ-A10SPF
TRANSDUCER 送受波器
XDRXDR SHIELD
10 9 8 7 6 5 4
520-5PWD 520-5MSD
T.YAMASAKI
Y.KIMURA
SPD0V/SHIELD TEMP NC NC TEMP0V XDR+
C2371-C01B
または
TRANSDUCER W/ SENSOR
選択 SELECT
水温・船速センサー付
OR
3 +12V
Mar. 3 '03
Mar. 3 '03
Mar. 3, '03
2 SPD
525ST-MSD 525ST-PWD
IEC61162
J2
APPROVED
XDR
IV-1.25SQ.
CHECKED
DWG.No.
12VDC/NMEA
GND *1
DRAWN
指示部
12VDC
SHIELD クロBLK RED アカ FUSE(1A)
TD-A
TD-B
RD-A
RD-B
J1 MJ-A7SPFD *3
3 4 5 6 7
*4. THREE-WAY CONVERSION CABLE NEEDED (OPTION).
*2. OPTION. *3. CONNECTOR PLUG FITTED AT FACTORY.
BLU
GRN V1.5/2.0/3.0
YEL
*3)コネクタは工場にて取付済み。
シロ
アオ
ミドリ
キ
*4)変換ケーブル組品が必要。
NAV EQUIPMENT
NMEA0183
SENSOR センサー
*1. SHIPYARD SUPPLY.
*1)造船所手配。
*2)オプション。
航法装置
電源
注記
NOTE
A
B

Your Local Agent/Dealer Your Local Agent/Dealer
9-52 Ashihara-cho, 9-52 Ashihara-cho, Nishinomiya, Japan Nishinomiya, Japan
FIRST EDITION : FIRST EDITION : MAR. MAR. 2003 2003 Printed in Japan Printed in Japan All rights reserved. All rights reserved.
PUB.No. PUB.No. OME-23710 OME-23710 *00014698000* ( HIMA HIMA ) LS-4100 LS-4100
* 0 0 0 1 4 6 9 8 0 0 0 * * 0 0 0 1 4 6 9 8 0 0 0 * *OME23710A00* * O M E 2 3 7 1 0 A 0 * * O M E 2 3 7 1 0 A 0 *
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.